首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 20 毫秒
1.
doi: 10.1111/j.1741‐2358.2011.00520.x The effect of long‐term disinfection procedures on hardness property of resin denture teeth Objective: The aim of the study was to evaluate the effect of long‐term disinfection procedures on the Vickers hardness (VHN) of acrylic resin denture teeth. Material and methods: Five acrylic resin denture teeth (Vipi Dent Plus‐V, Trilux–T, Biolux‐B, Postaris‐P and Artiplus‐A) and one composite resin denture teeth (SR‐Orthosit‐O) were embedded in heat‐polymerised acrylic resin within polyvinylchloride tubes. Specimens were stored in distilled water at 37°C for 48 h. Measurements of hardness were taken after the following disinfection procedures: immersion for 7 days in 4% chlorhexidine gluconate or in 1% sodium hypochlorite (CIm and HIm group, respectively) and seven daily cycles of microwave sterilisation at 650 W for 6 min (MwS group). In the WIm group, specimens were maintained in water during the time used to perform the disinfection procedures (7 days). Data were analysed with anova followed by the Bonferroni procedure (α = 0.01). Results: Microwave disinfection decreased the hardness of all acrylic resin denture teeth (p < 0.001). Immersion for 7 days in 4% chlorhexidine gluconate or distilled water had significant effect on the hardness of the acrylic resin denture teeth A (p < 0.01), and 1% sodium hypochlorite on teeth T (p < 0.01). All disinfection procedures decrease the hardness of the composite resin denture teeth (p < 0.01). Teeth O exhibited the highest and teeth V the lowest hardness values in the control group (p < 0.01). Conclusions: Disinfection procedures changed the hardness of resin denture teeth.  相似文献   

2.
doi:10.1111/j.1741‐2358.2009.00336.x
Effect of the physical properties of acrylic resin of overnight immersion in sodium hypochlorite solution Objectives: This study evaluated colour stability, surface roughness and flexural strength of microwave‐polymerised acrylic resin after overnight immersion in sodium hypochlorite, simulating 180 days use. Materials and methods: Forty disc‐shaped (15 mm × 4 mm) and 40 rectangular specimens (65 mm × 10 mm × 3 mm) were prepared from microwave‐polymerised acrylic resin. The specimens were immersed in 0.5, 1% sodium hypochlorite, Clorox/Calgon and distilled water. Colour measurements (ΔE) were determined by a portable colorimeter. A surface analyser was used to measure roughness (μm). The flexural strength (MPa) was measured using a three‐point bending test in a universal testing machine. Data were evaluated by one‐way anova , followed by Student–Newman–Keuls test (α = 0.05). Results: Statistical analysis found significantly higher colour changes (SNK, p < 0.001) for the 1% sodium hypochlorite, but mean ΔE value quantified by National Bureau of Standards was classified as slight. When comparing the surface roughness, no statistical significance was found among the solutions (anova , p = 0.637). The 1% sodium hypochlorite presented significantly lower flexural strength compared with the control group (SNK, p = 0.034). Conclusion: It was concluded that immersion in 1% sodium hypochlorite solutions for 8 h does influence the colour stability and flexural strength of microwave‐polymerised acrylic resin, during the simulated period of 180 days.  相似文献   

3.
Background: Failure of bonding between acrylic resin teeth and denture base material is a considerable problem for patients who wear complete dentures. Objective: The purpose of this study was to evaluate the bond strength between acrylic resins and resin denture teeth with different thermocycling and polymerisation methods. Materials and methods: Microwave‐polymerised (Onda‐Cryl), heat‐polymerised (Clássico) and autopolymerising (Jet) acrylic resins and resin denture tooth (Biotone) were used. The acrylic resins were polymerised according to the following: (A) microwave – fast cycle, Onda‐Cryl; (B) microwave – long cycle, Onda‐Cryl; (C) microwave – manufacturer’s cycle, Onda‐Cryl; (T) water bath – long cycle, Clássico; and (Q) bench polymerisation cycle, Jet. Twenty specimens were prepared for each polymerisation method. Ten were thermocycled, and 10 did not receive thermocycling. For the purpose of the study, a shear test was used. Data were analysed with the Kruskal–Wallis test and Dunn’s multiple comparisons test (p = 0.05). Results: Cycles B, C and T were similar (p > 0.05), and had statistically higher bonding values than cycles A and Q (p < 0.05) for the thermocycled and non‐thermocycled groups. For all cycles, there were no statistically significant differences between thermocycled and non‐thermocycled groups (p > 0.05), except for cycle Q (p = 0.0038). Conclusion: Thermocycling decreased the bond strength, but not significantly for microwave and heat‐polymerised cycles. Regarding the bond strength of denture teeth to acrylic resin, the fast microwave polymerisation cycle should be avoided when polymerising Onda‐Cryl acrylic resin. In addition, Jet acrylic resin is not adequate for use in denture repair.  相似文献   

4.
Background: Ocular prosthesis materials should have specific properties for their indication and durability; therefore, it is important to investigate their physical behaviour when affected by several disinfectants. Objectives: This study evaluated the influence of different disinfecting solutions on the microhardness and surface roughness of acrylic resins for ocular prosthesis. Materials and Methods: Fifty samples simulating ocular prostheses were fabricated with N1 resin and colourless resin and divided (n = 10) according to the disinfectant used: neutral soap, Opti‐free, Efferdent, 1% hypochlorite (HYC) and 4% chlorhexidine (CHX). Samples were stored in saline solution at 37°C and disinfected during 120 days. Both microhardness and roughness were investigated before, after 60 days and 120 days of disinfection and storage. Microhardness was measured using a microhardner and the roughness with a roughness device. Results: N1 resin showed lower microhardness when compared with colourless resin (p < 0.05). HYC and CHX groups exhibited the highest change of microhardness and roughness values (p < 0.05). An increase in roughness and reduction in microhardness of ocular acrylic resins were observed after both periods of disinfection and storage (p < 0.05). Conclusion: Both disinfection/storage periods affected the microhardness and roughness values of the samples.  相似文献   

5.
doi: 10.1111/j.1741‐2358.2012.00676.x Effect of thermal cycling and disinfection on colour stability of denture base acrylic resin Objectives: The purpose of this study was to investigate the effect of thermal cycling and disinfection on the colour change of denture base acrylic resin. Materials and Methods: Four different brands of acrylic resins were evaluated (Onda Cryl, QC 20, Classico and Lucitone). All brands were divided into four groups (n = 7) determined according to the disinfection procedure (microwave, Efferdent, 4% chlorhexidine or 1% hypochlorite). The treatments were conducted three times a week for 60 days. All specimens were thermal cycled between 5 and 55°C with 30‐s dwell times for 1000 cycles before and after disinfection. The specimens’ colour was measured with a spectrophotometer using the CIE L*a*b* system. The evaluations were conducted at baseline (B), after first thermal cycling (T1), after disinfection (D) and after second thermal cycling (T2). Colour differences (ΔE) were calculated between T1 and B (T1B), D and B (DB), and T2 and B (T2B) time‐points. Results: The samples submitted to disinfection by microwave and Efferdent exhibited the highest values of colour change. There were significant differences on colour change between the time‐points, except for the Lucitone acrylic resin. Conclusions: The thermal cycling and disinfection procedures significantly affected the colour stability of the samples. However, all values obtained for the acrylic resins are within acceptable clinical parameters.  相似文献   

6.
Background: The fracture between acrylic denture base material and artificial teeth is a common clinical occurrence in dental prosthodontic practice. Objective: To evaluate the bond strength between acrylic resins and resin denture teeth when submitted by two protocols of monomer liquid application on the tooth surface and using different polymerisation methods. Material and methods: Microwave‐polymerised (Onda‐Cryl), heat‐polymerised (Clássico) and autopolymerising (Jet) acrylic resins and a brand of resin denture teeth (Biotone) were used. The acrylic resins were polymerised according to the cycles: (A) microwave – fast cycle, Onda‐Cryl; (B) microwave – long cycle, Onda‐Cryl; (C) microwave – manufacturer’s cycle, Onda‐Cryl; (T) water bath – long cycle, Clássico and (Q) bench polymerisation cycle, Jet. Thirty specimens were prepared for each polymerisation method; 10 were packed with acrylic resin after 60 s of monomer liquid application on the tooth surface, 10 after 180 s and 10 without any monomer liquid application. For the purpose of the study, a shear test was used. anova and Tukey tests were performed to identify significant differences (α = 0.05). Results: The highest bond strength values were found for monomer surface treatments, regardless of the polymerisation cycles. The highest significant values were found for cycles B (15.4 ± 1.8 MPa), C (11.9 ± 4.9 MPa) and T (15.4 ± 2.6 MPa) for non‐treated and 60 s methylmethacrylate treated groups. Comparing the monomer liquid treatment, they did not differ significantly (p > 0.05), except for cycle A (p < 0.05). Conclusion: Chemical treatment using monomer on the tooth surface prior to the acrylic resin packing improved the bond strength between resin denture tooth and acrylic resin, regardless of monomer liquid treatment protocols. The microwavable resin, polymerised by fast cycle and autopolymerising resin should be avoided for processing denture and denture repairs, respectively.  相似文献   

7.
doi:10.1111/j.1741‐2358.2009.00333.x
Effect of microwave treatment on the shear bond strength of different types of commercial teeth to acrylic resin Objective: The purpose of this study was to verify the effect of microwave treatment on the shear bond strength of commercial types of teeth to acrylic resin, when the glossy ridge laps were unmodified (groups 1 and 5), bur abraded (groups 2 and 6), bur grooved (groups 3 and 7) or etched by monomer (groups 4 and 8). Background: Controversial findings have shown that mechanical or chemical changes in ridge‐lap surface of the tooth increase or decrease the bond strength between tooth and acrylic resin, and the microwave disinfection may cause different changes on this bond strength. Materials and methods: Eighty specimens (n = 10) were made with the acrylic resin bonded to tooth glossy ridge lap, polymerised in water at 74°C for 9 h, and deflasked after flask cooling. Specimens of the groups 5, 6, 7 and 8 were individually immersed in 150 ml of water and submitted to microwave treatment in an oven at 650 W for 3 min. Control specimens (groups 1, 2, 3 and 4) were not microwave treated. Shear bond strength test was performed in an Instron machine with a cross‐speed of 1 mm/min. Collected data were submitted to anova and Tukey’s test (α = 0.05). Results: Microwave treatment decreased the shear bond strength values of the tooth/resin bond. In the microwaved and non‐microwaved procedures, mechanical retention improved the shear bond strength when compared with the control and monomer treatments. Conclusion: Shear bond strength of the tooth/resin bond was influenced by the microwave treatment and different commercial teeth association, and was lower for the Biotone tooth.  相似文献   

8.
doi:10.1111/j.1741‐2358.2009.00321.x
Flexural properties of repaired heat‐polymerising acrylic resin after wetting with monomer and acetone Objectives: Repair strength can be improved by treating fractured surfaces of a denture. Background: This study investigated flexural properties of heat‐polymerised acrylic resin specimens repaired with auto‐polymerising and visible light curing (VLC) resins after the repair surfaces were wetted with monomers or acetone. Materials and Methods: Fifty‐four specimens (65 × 10 × 2.5 mm) were prepared and 48 of them were sectioned to simulate denture fracture. Butt‐joint designed repair surfaces were wetted with heat‐, auto‐polymerising monomers and acetone for 180 s and repaired with auto‐polymerising and VLC resins. After repairs, specimens were subjected to three‐point bending test and flexural strength, strain, fracture load, modulus of elasticity and deflection values were recorded. Data were analysed with Student t and LSD tests (p ≤ 0.05). Results: Overall flexural strength, strain, fracture load and deflection values of specimens repaired with VLC resin were significantly higher than the specimens repaired with auto‐polymerising resin for all types of wetting agent (p < 0.05). Within the wetting agents, heat‐ and auto‐polymerising monomers produced the best mechanical properties, while wetting with acetone did not provide superior effect over both monomers. Conclusion: In clinical use, wetting the repair surfaces may result in stronger repairs. The use of bonding agent in VLC resin repairs in combination with wetting agent results in improved flexural properties.  相似文献   

9.
Background: Denture base acrylic resin is easily colonised by oral endogenous bacteria and Candida spp., and eventually by extra‐oral species such as Staphylococcus spp., Pseudomonadaceae or members of Enterobacteriaceae. This microbial reservoir can be responsive for denture related stomatitis and aspiration pneumonia, a life‐threatening infection especially in geriatric patients. However, the oral and denture hygiene of dependant elderly individuals is extremely poor. Objective: This in vitro study aimed to determine the per cent of a quaternary ammonium compound heat‐polymerised in acrylic resin necessary to obtain denture base displaying antiseptic properties. Design: Acrylic resin discs containing 2–50% ammonium polymer (Poly 202063A; 0% control) were soaked in artificial saliva for 4 weeks. Resin discs were incubated for 24 hours with Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa [37°C, brain–heart infusion (BHI) broth and phosphate‐buffered saline (PBS) buffer] and Candida albicans (30°C, Schaedler broth), in 15 ml (168 discs) and 600 μl (168 discs) of inoculum. Microbial growth was verified at t 0 hours and t 24 hours. Data were recorded as the mean of three colony forming unit (CFU) numerations. The borderline of antimicrobial effect was determined at 0.1% viable cells. Results: In 600 μl of PBS inoculum, resin specimens had a bactericidal effect (E. coli and S. aureus: 2%; P. aeruginosa: 10%) and a fungicidal effect (C. albicans: 50%). Long‐term stability and toxicity in vivo studies are now required. Conclusion: A 2% quaternary ammonium compound polymerised with a denture acrylic resin displayed antiseptic properties after a 4‐week soaking period in artificial saliva. Such antiseptic denture base could help geriatric patients to improve their oral health.  相似文献   

10.
doi: 10.1111/j.1741‐2358.2011.00454.x Influence of surface treatments on the flexural strength of denture base repair Objective: The purpose of this study was to evaluate the flexural strength of repairs made with autopolymerising acrylic resin after different treatments of joint surfaces. Material and Methods: Fifty rectangular specimens were made with heat‐polymerised acrylic resin and 40 were repaired with autopolymerising acrylic resin following joint surface treatments: group 1 (intact specimens), group 2 (chemical treatment: wetting with methyl‐methacrylate for 180 s), group 3 (abraded with silicon carbide paper), group 4 (abraded and wetting with methyl‐methacrylate for 180 s) and group 5 (without surface treatment). The flexural strength was measured by a three‐point bending test using a universal testing machine with a 100 Kgf load cell in the centre of repair at 5 mm/min cross‐head speed. All data were analysed using one‐way anova and Tukey HSD test for multiple comparisons (p < 0.05). Results: Among repaired specimens, groups 2 and 4 had 66.53 ± 3.4 and 69.38 ± 1.8 MPa mean values and were similar. These groups had superior flexural strength than groups 3 and 5 that were similar and had 54.11 ± 3.4 and 51.24 ± 2.8 MPa mean values, respectively. Group 1 had a mean value of 108.30 ± 2.8 MPa being the highest result. Conclusion: It can be concluded that the treatment of the joint surfaces with methyl‐methacrylate increases the flexural strength of denture base repairs, although the strength is still lower than that observed for the intact denture base resin. Abrasion with sandpaper was not able to influence the flexural strength of repaired denture bases.  相似文献   

11.
Objective: This study evaluated the surface roughness (Ra) and color stability of acrylic resin colors (Lucitone 550, QC‐20 and Vipi‐Wave) used for fabricating bases for complete, removable dentures, overdentures and prosthetic protocol after immersion in chemical disinfectants (1% sodium hypochlorite and 2% peracetic acid) for 30 and 60 minutes. Material and Methods: Sixty specimens were made of each commercial brand of resin composite, and divided into 2 groups according to the chemical disinfectants. Specimens had undergone the finishing and polishing procedures, the initial color and roughness measurements were taken (t=0), and after this, ten test specimens of each commercial brand of resin composite were immersed in sodium hypochlorite and ten in peracetic acid, for 30 and 60 minutes, with measurements being taken after each immersion period. These data were submitted to statistical analysis. Results: There was evidence of an increase in Ra after 30 minutes immersion in the disinfectants in all the resins, with QC‐20 presenting the highest Ra values, and Vipi‐Wave the lowest. After 60 minutes immersion in the disinfectants all the resins presented statistically significant color alteration. Conclusions: Disinfection with 1% sodium hypochlorite and peracetic acid altered the properties of roughness and color of the resins.  相似文献   

12.
doi: 10.1111/j.1741‐2358.2011.00582.x Effect of toothbrushing, chemical disinfection and thermocycling procedures on the surface microroughness of denture base acrylic resins Objective: This study verified the surface microroughness of denture acrylic resins submitted to toothbrushing, chemical disinfection and thermocycling procedures. Material and methods: Samples were prepared according to conventional, microwaved and boiled resins and submitted to microroughness measurements before and after procedures using a profilometer (Ra). Data were subjected to anova and Tukey’s test (5%). Results: Before thermocycling, a difference was found among treatments for microwaved and boiled resins, with greater values for toothbrushing and lower values for Efferdent and hypochlorite; control was intermediate. Differences among resins were observed for treatments, with higher values for boiled resin and lower values for conventional and microwaved resins. After thermocycling, differences were found for microwaved resin, with a higher value for toothbrushing and a lower value for Efferdent and hypochlorite; control was intermediate. Tooth‐brushed boiled resin presented higher values and hypochlorite lower values; control and Efferdent were intermediates. Differences among resins were seen for treatments, with higher values for boiled resin and lower values for conventional and microwaved resins. Boiled resin presented differences for toothbrushing and hypochlorite, before and after thermocycling procedures were compared. Conclusions: For microwaved and boiled resins, toothbrushing and chemical disinfection promoted different levels of surface microroughness when associated or not with thermocycling.  相似文献   

13.
doi: 10.1111/j.1741‐2358.2012.00657.x The effect of immersion cleansers on gloss, colour and sorption of acetal denture base material Objective: To study the effect of peroxide and hypochlorite cleansers on gloss, colour and sorption of acetal denture resins. Materials and methods: Pink acetal and thermoplastic acrylic resins were evaluated. Thirty‐five specimens 39 × 39 × 1.8 mm of each resin were prepared. Each group of specimens (n = 7) was then immersed into cleansers for 100 days. Group I immersed in tap water, Group II in Corega Extradent for 5 min, Group III in Corega Extradent for 8 h, Group IV in NitrAdine? Seniors for 15 min and Group V in NaOCl 5.25%. Gloss, colour and weight measurements were taken initially and after 100 days. Data subjected to two‐way anova and Tukey’s test at α = 0.05. Results: Acrylic resin showed reductions of glossiness from ?5 to ?15 and acetal from ?0.2 to ?6. Colour changes (ΔΕ*) ranged from 2.64 to 7.64 for acrylic and 2.77 to 26.54 for acetal resin. Sorption for acrylic ranged from 11.64 to 17.06 μg/mm3 and 9.18 to 24.79 μg/mm3 for acetal resin. The results of (ΔΕ*) and sorption showed an interaction between denture resins and cleansers. Conclusions: The gloss of acetal resin was less affected by water, peroxides and NaOCl 5.25% compared with acrylic resin. Acetal resin showed clinically acceptable (ΔΕ*) whereas acrylic resin unacceptable ones for water and peroxide solutions. The immersion of acetal resin in NaOCl 5.25% showed clinically unacceptable (ΔΕ*) and higher sorption and should be avoided or should be managed with care.  相似文献   

14.
doi:10.1111/j.1741‐2358.2009.00307.x
Effect of flask closure method and post‐pressing time on the upper denture base adaptation Objectives: The purpose of this study was to evaluate the effect of flask‐closure methods, post‐pressing times and acrylic resins on denture base adaptation. Materials and methods: The resins were flasked using a hydraulic press and closed with the traditional clamp or RS system. Conventional heat‐cure resin was polymerised immediately or at 6 h post‐pressing at 74°C for 9 h. Rapid cycle heat‐cure resin was polymerised in boiling water for 20 min. After cooling, the bases were deflasked and the sets of cast‐base transversally sectioned in the regions distal to the canine, mesial to the first molar and in the posterior palatal zone. The adaptation was measured with an optical microscope (0.0005 mm) at five reference points for each section. Data were analysed using anova and Tukey’s test (α = 0.05). Results: Traditional clamp and immediate post‐pressing time improved base adaptation for conventional heat‐cure resin. Both post‐pressing times showed most accurate base adaptation for conventional heat‐cure resin when the traditional clamp was used. Immediate post‐pressing time improved base adaptation for conventional heat‐cure resin and the 6‐h delay in time was significant for the rapid cycle heat‐cure resin. Conclusions: Traditional clamp and immediate post‐pressing time improved base adaptation for conventional heat‐cure resin.  相似文献   

15.
Objective: The purpose of this in vitro study was to evaluate the antimicrobial activity of acrylic resins containing different percentages of silver and zinc zeolite, and to assess whether the addition of zeolite alters the flexural and impact strength of the resins. Background: The characteristics of acrylic resins support microorganism development that can threaten the health of the dentures user. Material and methods: A microwave‐polymerised (Onda‐Cryl) and two heat‐polymerised (QC20 and Lucitone 550) acrylic resins were used. The materials were handled according to the manufacturers’ instructions. Fifty rectangular‐shaped specimens (8 × 10 × 4mm) were fabricated from each resin and assigned to 5 groups (n = 10) according to their percentage of Irgaguard B5000 silver–zinc zeolite (0%– control, 2.5%, 5.0%, 7.5% and 10%). Flexural strength and Izod impact strength were evaluated. The antimicrobial activity against two strains of Candida albicans and two strains of Streptococcus mutans was assessed by agar diffusion method. Data were analysed statistically by one‐way anova and Tukey’s test at 5% significance level. Results: The addition of 2.5% of Irgaguard B5000 to the materials resulted in antimicrobial activity against all strains. Flexural strength decreased significantly with the addition of 2.5% (QC20 and Lucitone 550) and 5.0% (Onda‐Cryl) of Irgaguard B5000. The impact strength decreased significantly with the addition of 2.5% (Lucitone 550) and 5.0% (QC20 and Onda‐Cryl) of zeolite. Conclusion: The addition of silver–zinc zeolite to acrylic resins yields antimicrobial activity, but may affect negatively the mechanical properties, depending on the percentage of zeolite.  相似文献   

16.
Aims: This study aimed to compare the efficacy of different disinfection methods in eliminating Salmonella contamination from turkey houses. Methods and Results: Fifty depopulated turkey houses which had all housed Salmonella‐positive flocks were visited after cleaning and disinfection. A minimum of 45 swab samples from different surfaces were taken per house and analysed for the presence of Salmonella. The sampled surfaces included intact floor surfaces, floor cracks, walls, feeders, drinkers, anteroom, nestboxes and miscellaneous items. Houses were grouped according to the disinfectant which had been used and the efficacy of the different groups of disinfectants was compared. Sixty‐eight % of houses tested positive for Salmonella after C&D. Out of 4440 samples, 207 tested positive for Salmonella, giving an overall sample prevalence of 4·7%. There was no significant difference in the level of residual contamination between breeding, rearing and finishing houses. Products containing a mixture of formaldehyde, glutaraldehyde and quaternary ammonium compounds (QAC) performed significantly better than products containing hydrogen peroxide and peracetic acid. Cleaning and disinfection was least effective in nestboxes and anterooms. Conclusions: Thorough cleaning and the choice of a suitable disinfectant are crucial if Salmonella contamination of turkey houses is to be eliminated. Significance and impact of the study: This study shows that disinfectants containing a mixture of formaldehyde, glutaraldehyde and QAC perform significantly better under field conditions than oxidising products and should therefore be the first choice for disinfection of turkey premises where Salmonella is present.  相似文献   

17.
doi: 10.1111/j.1741‐2358.2011.00570.x Effect of disinfection and storage on the flexural strength of ocular prosthetic acrylic resins Objective: To evaluate the influence of chemical disinfection and storage duration on the flexural strength of acrylic resins commonly used to make ocular prostheses. Methods: A total of 260 samples were manufactured with N1 resin and colourless resin. Both resins were thermopolymerised using a microwave oven. Samples were stored and periodically disinfected and were divided into groups: control (no disinfection) (I), neutral soap (II), Opti‐free (III), Efferdent (IV), 1% hypochlorite (V) or 4% chlorhexidine (VI). The flexural strength was measured before and after 60 and 120 days of storage. Data were analysed by anova and Tukey test (0.05). Results: The flexural strength of the N1 resin was higher than that for the colourless resin. There was a significant difference in the flexural strength before and after 60 and 120 days of storage with disinfection, regardless of the resin and disinfectant. Group I in the initial period exhibited greater flexural strength, with significant difference only in group VI after 120 days. Conclusion: It can be concluded that the flexural strength only changed after 120 days of storage for samples disinfected with chlorhexidine. However, all flexural strength values obtained herein were acceptable clinical limits for the acrylic resins.  相似文献   

18.
Gerodontology 2012; doi: 10.1111/j.1741‐2358.2011.00522.x
Evaluation of stain removal and inhibition properties of eight denture cleansers: an in vitro study Objectives: To determine the ability of eight denture cleansers to remove and inhibit tea‐stain build‐up on acrylic resin. Materials and methods: In the stain removal study, Perspex® (cast heat polymerised resin) specimens previously soaked in saliva were stained using multiple exposures of chlorhexidine and tea solutions. Specimens were exposed for 1 min to one of the eight denture cleansers for five cycles, washed and dried and their optical density read on a uv/vis spectrophotometer at 295 nm. In the stain inhibition study, clear specimens were exposed to saliva followed by cleansers then tea solution, for five cycles. The build‐up of stain at each cycle was measured, and differences in optical densities from baseline were calculated. Results: All denture cleansers were significantly more effective than water in removing stain (p < 0.05). There were significant differences in cleaning ability between cleansers (p < 0.001), Dentural® and Kleenite® were particularly effective. The stain inhibition experiment showed that most cleansers were significantly more effective than water in inhibiting stain (p < 0.05). There were significant differences in inhibition ability between cleansers (p < 0.01). Kleenite® and Equate were particularly effective. Conclusions: All denture cleansers had a capacity to remove stain and most had an inhibitory effect on staining. Kleenite® was particularly effective in controlling stain formation.  相似文献   

19.
doi: 10.1111/j.1741‐2358.2011.00516.x Effect of repeated microwave disinfections on bonding of different commercial teeth to resin denture base Objective: To verify the influence of repeated microwave disinfections on the shear bond strength of two commercial types of teeth to acrylic resin, when the ridge lap surfaces were unmodified, bur abraded, bur grooved or etched by monomer. Material and methods: Eighty specimens (n = 10) were adhered to the tooth ridge lap surface, polymerised in a water bath at 74°C for 9 h. Microwaved specimens were individually immersed in 150 ml of water and submitted to five simulated disinfections in a microwave oven calibrated at 650 W for 3 min. Control specimens were not microwave treated. Shear bond strength tests were performed in an Instron machine with a cross‐speed of 1 mm/min. The fracture load values were transformed into shear bond strength as a function of the bonding area (0.28 cm2). Data were submitted to anova and Tukey’s test (α = 0.05). Fractured areas were classified as adhesive, cohesive (resin or tooth) or mixed failures. Results: Repeated microwave disinfections increased the shear strength of the tooth/resin bond. Mechanical retention in microwaved and non‐microwaved procedures improved the shear bond strength. Conclusions: The different commercial types of teeth influenced shear bond strength values, with Biotone teeth showing the lower values.  相似文献   

20.
Aims: To assess the antimicrobial action of three natural‐derived products (essential oil, decoction and hydrosol of Satureja thymbra) against biofilms, composed of useful, spoilage and pathogenic bacteria (formed as monoculture or/and mixed‐culture), and to compare their efficiency with three standard acid and alkaline chemical disinfectants. Methods and Results: Two acids (hydrochloric and lactic, pH 3), one alkali (sodium hydroxide, pH 11), the essential oil of S. thymbra (1% v/v) and the two by‐products of the essential oil purification procedure (the decoction and the hydrosol fraction of essential oil, 100%), were tested against biofilms formed by five bacterial species, either as monospecies, or as mixed‐culture of all species. The tested bacterial species were Staphylococcus simulans and Lactobacillus fermentum (useful technological bacteria), Pseudomonas putida (spoilage bacterium), Salmonella enterica and Listeria monocytogenes (pathogenic bacteria). Biofilms were left to be formed on stainless steel coupons for 5 days at 16°C, before the application of disinfection treatments, for 60 and 180 min. The disinfection efficiency was evaluated by detaching the remaining viable biofilm cells and enumerating them by agar plating, as well as by automated conductance measurements (using Rapid Automated Bacterial Impedance Technique). Both these methods revealed that the essential oil and the hydrosol of S. thymbra exhibited a strong antimicrobial action against both monospecies and mixed‐culture biofilms. Surprisingly, the efficiency of the other three acid–base disinfectants was not adequate, although a long antimicrobial treatment was applied (180 min). Conclusions: The essential oil of S. thymbra (1%), as well as its hydrosol fraction (100%), presents sufficient bactericidal effect on bacterial biofilms formed on stainless steel. Significance and Impact of the Study: Use of natural antimicrobial agents could provide alternative or supplemented ways for the disinfection of microbial‐contaminated industrial surfaces.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号