首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The design and construction of delivery vectors with high stability and effective cellular uptake efficiency is very important. In this study, a novel polymeric liposomes (PLs) formed from PEGylated octadecyl‐quaternized lysine modified chitosan (OQLCS) and cholesterol with higher size stability and cellular uptake efficiency has been synthesized successfully. Compared to conventional liposomes (CLs; phosphatidyl choline/cholesterol), the calcein‐loaded PLs exhibited a multi‐lamellar structure with homogenous size diameter (200 nm) and high calcein encapsulation efficiency (about 92%). PLs could be stored at different temperature (25, 4, and ?20°C) and different medium (deionized water, phosphate‐buffered saline, and human plasma solution) for up to 4 weeks without significant size change. The spectrophotometer fluorometry analysis and the flow cytometry analysis indicated that in comparison with CL, PLs with positive zeta potential facilitates the uptake of calcein by MCF‐7 tumor cells. The data suggests that PLs may provide a new method to overcome the stability and enhance the uptake efficiency of CLs. Biotechnol. Bioeng. 2010;106: 952–962. © 2010 Wiley Periodicals, Inc.  相似文献   

2.
A rapid and sensitive high-performance thin-layer chromatographic (HPTLC) method was developed and validated for the quantitative estimation of boswellic acids in formulation containing Boswellia serrata extract (BSE) and 11-keto beta-boswellic acid in human plasma. Simple extraction method was used for isolation of boswellic acid from formulation sample and acidified plasma sample. The isolated samples were chromatographed on silica gel 60F(254)-TLC plates, developed using ternary-solvent system (hexane-chloroform-methanol, 5:5:0.5, v/v) and scanned at 260 nm. The linearity range for 11-KBA spiked in 1 ml of plasma was 29.15-145.75 ng with average recovery of 91.66%. The limit of detection and limit of quantification for 11-KBA in human plasma were found to be 8.75 ng/ml and 29.15 ng/ml. The developed method was successfully applied for the assay of market formulations containing BSE and to determine plasma level of 11-keto beta-boswellic acid in a clinical pilot study.  相似文献   

3.
A new, simple, sensitive, selective and precise HPTLC method has been developed for the determination of taraxerol in Clitoria ternatea L. Determination of taraxerol was performed on TLC aluminium plates. Linear ascending development was carried out in twin trough glass chamber saturated with hexane and ethyl acetate (80:20 v/v). The plate was then dried and sprayed with anisaldehyde reagent. A Camag TLC scanner III was used for spectrodensitometric scanning and analysis at 420 nm. The system was found to give compact spots for taraxerol (R(f) 0.53). The calibration plot was linear in the range of 100-1200 ng of taraxerol. The correlation coefficient of 0.9961 was indicative of good linear dependence of peak area on concentration. The concentration of taraxerol was found to be 12.4 mg/g w/w in the hydroalcoholic extract of C. ternatea root. To study the accuracy and precision of the method, recovery studies were performed. Recovery values from 99.65 to 99.74% showed excellent reliability and reproducibility of the method. The limits of detection and quantification were determined to be 31 and 105 ng/spot, respectively. The proposed HPTLC method for quantitative monitoring of taraxerol in C. ternatea can be used for routine quality testing of C. ternatea extract used in Ayurvedic formulations.  相似文献   

4.
A rapid and sensitive high-performance thin-layer chromatography (HPTLC) method has been developed for the measurement of lansoprazole in human plasma and its use for pharmacokinetic study has been evaluated. Detection and quantitation were performed without using an internal standard. A single stage extraction procedure was followed for extracting lansoprazole from plasma and a known amount of the extract was spotted on precoated silica gel 60 F254 plates using a Camag Linomat IV autosampler. Lansoprazole was quantified using a Camag TLC Scanner 3. The recovery study of authentic analytes added to plasma at 0.05 to 0.25 μg/ml was 95.37±2.15% and the lowest amount of lansoprazole that could be detected was 20 ng/ml plasma. The method provides a direct estimate of the amount of lansoprazole present in plasma. The method was used for the determination of plasma levels as well as pharmacokinetic parameters of lansoprazole after oral administration of two marketed preparations to healthy volunteers.  相似文献   

5.
Cocaine and ethanol are frequently used at the same time, resulting in the formation of cocaethylene by transesterification. We studied the capability of high-performance thin-layer chromatography (HPTLC) to simultaneously detect cocaethylene, cocaine and benzoylecgonine in 16 urine specimens of drug addicts, previously tested as positive for benzoylecgonine at immunoenzymatic screening. Accuracy and precision, as well as detection and quantitation limits of the method, were evaluated by comparison with high-performance liquid chromatography (HPLC). HPTLC limit of quantitation was 1.0 μg/ml for the three compounds, whereas HPLC limits were 0.2 μg/ml for benzoylecgonine and cocaine, and 0.1 μg/ml for cocaethylene. The relative standard deviation (RSD) ranged from 1.03 to 12.60% and from 1.56 to 16.6% for intra- and inter-day HPTLC analysis, respectively. In the case of the HPLC method, the RSD for the intra-day precision ranged from 0.79 to 5.05%, whereas it ranged from 1.19 to 10.64% for the inter-day precision. In comparison with HPLC, HPTLC is less expensive and faster, requiring 2–3 h to analyze 10–12 samples on a single plate. In conclusion, HPTLC is suitable for determinations of the three analytes only for samples with high concentrations.  相似文献   

6.
A sensitive and simple HPTLC method was developed for estimation of ranitidine in human urine. The drug was extracted from urine after basification using dichloromethane. Dichloromethane extract was spotted on silica gel 60 F254 TLC plate and was developed in a mixture of ethyl acetate-methanol-ammonia (35:10:5 v/v) as the mobile phase and scanned at 320 nm. The RF value obtained for the drug was 0.67 +/- 0.03. The method was validated in terms of linearity (50-400 ng/spot), precision and accuracy. The average recovery of ranitidine from urine was 89.35%. The proposed method was applied to evaluate bioequivalence of two marketed ranitidine tablet formulations (150 mg, Formulation I and Formulation 2) using a crossover design by comparing urinary excretion data for unchanged ranitidine in six healthy volunteers. Various pharmacokinetic parameters like peak excretion rate [(dAU/dt)max], time for peak excretion rate (tmax), AUC0-24, AUC0-infinity, cumulative amount excreted were calculated for both formulations and subjected to statistical analysis. The relative bioavailability of Formulation 2 with respect to Formulation 1 was 93.76 and 95.31% on the basis of AUC0-24 and cumulative amount excreted, respectively. Statistical comparison of various pharmacokinetic parameters indicated that the two ranitidine tablet formulations are bioequivalent.  相似文献   

7.
A simple and rapid high-performance thin-layer chromatographic (HPTLC) determination of 5-methoxypsoralen in serum is necessary for the therapeutic survey of patients treated with Puvatherapy (psoralen+UV A). The assay for this biological fluid involves an extraction with heptane-dichloromethane (4:1, v/v). The analytical method is linear from 50 to 250 ng/ml. This assay range is adequate for analysing human serum, as it corresponds to psoralen concentrations measured in serum from patients treated with psoralen and UV A against psoriasis and vitiligo. The limit of detection is 15 ng/ml. The coefficient of variation was less than 7%.  相似文献   

8.
A highly sensitive and selective method for the determination of cholesterol is required to evaluate trace amounts of cholesterol in test samples. In this work, selected gold nanoparticles (AuNPs) and 5‐amino‐2‐mercapto‐1,3,4‐thiadiazole (AMT) were used and a thin film of three‐dimensional gold–AMT core–shell nanoparticles (p‐AMT–AuNPs) was prepared using an electrochemical method. Cholesterol oxidase was then bonded to the film surface to give a functional electrode. Based on catalysis by the electrode functionalized for cholesterol and a luminol–H2O2 electrochemiluminescence (ECL) system, a highly sensitive and selective ECL method was developed for the determination of cholesterol. Under optimized conditions, ECL intensity showed a good linear relationship with cholesterol over the concentration range 0.05–11.0 µg/ml, with a correlation coefficient of 0.999 and a limit of detection of 0.02 µg/ml. The proposed method was used to determine cholesterol in dairy products with a relative standard deviation of < 1.8% and recovery rates of 98.1–104%. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

9.
Liposomes are widely used vehicles for the delivery of bioactive molecules. They are composed mainly from acyl-phosphatidylcholines, cholesterol, and charged lipids (e.g., stearylamine, dipalmitoylphosphatidylglycerol (DPPG), phosphatidylethanolamine).

The incorporation efficiencies of the bioactive molecule and the drug to lipid molar ratio are important factors for the assessment of the liposomal formulation. In order to successfully characterize a liposomal formulation, it is necessary to be able to accurately measure the lipids and the encapsulated molecule, using the smallest possible sample.

The present work describes an analytical methodology on qualitative and quantitative determination of all the lipid ingredients that are involved in the liposome formulation, as well as the drug incorporation and the drug–lipid ratio, by a simultaneous measurement of all the liposomal ingredients using thin-layer chromatography coupled with a flame ionization detector (HPTLC/FID).

The procedure requires only one measurement per sample, and it can be applied even in very small or much diluted samples.

The proposed analytical method can be applied in general on all steps of the development of liposomal formulations. The purity and stability of the raw materials can also be easily evaluated. In addition the preparation procedure can be tracked in order to locate possible losses of raw material and errors of the preparation method resulting in the amelioration of the method.  相似文献   

10.
A modified method for the determination of glycosphingolipid glycosyltransferase activity using high-performance thin-layer chromatographic (HPTLC) plates has been developed. An acceptor glycosphingolipid was chromatographed on an HPTLC plate and was incubated with an enzyme mixture and an appropriate radioactive sugar nucleotide. After incubation, the plate was washed with phosphate buffer and 2% Tween 80. The radiolabeled reaction product was scrapped off the plate and the radioactivity determined using a liquid scintillation counter or, alternatively, the plate was exposed to an X-ray film to reveal the radioactive product. We have used this assay method to determine the activities of rat brain cytidine 5'-monophosphate-N-acetylneuraminic acid: LacCer-, GM3-, GM1-, or GD3-sialyltransferases. This method is sensitive, fast, and reliable and is capable of assaying simultaneously the activities of glycosyltransferases with multiple acceptor specificity. It should be useful in monitoring the enzyme activities present in various column fractions during chromatographic fractionation of glycosyltransferases with different substrate specificities.  相似文献   

11.
A gas chromatographic–mass spectrometric method was developed for the determination of residues of clenbuterol in bovine urine. The method involves a simple cation-exchange clean-up and concentration of clenbuterol in the acidified urine, followed by ethyl acetate extraction. The analyte is determined as the di-trimethylsilyl derivative and quantitated against an internal standard of penbutolol. Using a 5-ml sample of urine, a detection limit of 0.07 ng/ml can be achieved with recoveries close to 100% for fortification levels of 0.2 and 1 ng/ml. By increasing the sample volume to 50 ml, a detection limit below 0.01 ng/ml was achievable with recovery averaging 70%. The coefficient of variation of the assay ranged from 15% at 0.01 ng/ml (50-ml sample) to 6% at 1 ng/ml (5-ml sample). It was demonstrated that the method can detect the presence of clenbuterol in bovine urine at sub-ppb (ng/ml) levels using low resolution GC–MS with electron impact (EI) ionization.  相似文献   

12.
Esterase inhibition assays provide an effect-directed tool of rapid screening for inhibitors in environmental and food samples. According to a multi-enzyme microtiter-plate assay, rabbit liver esterase (RLE), Bacillus subtilis esterase (BS2), and cutinase from Fusarium solani pisi (CUT) were used for the detection of 21 organophosphorus and carbamate pesticides by high-performance thin-layer chromatography–enzyme inhibition assays (HPTLC–EI). Staining was performed with Fast Blue Salt B coupling to α-naphthol enzymatically released from the respective acetate used as substrate. Quantitative analysis was achieved by densitometric evaluation at 533 nm. Enzyme inhibition factors derived from HPTLC–EI were calculated from the slopes of the linear calibration curves, which allowed comparisons to published inhibition constants and well correlated to sensitivity parameters. Limits of detection ranged from a few pg/zone for organophosphates as strongest inhibitors to a few ng/zone for most carbamates, when RLE and BS2 were used. Without oxidation, chlorpyrifos and parathion were directly detectable at approximately 60 and 14 ng/zone, respectively. As the enzyme of lowest sensitivity, CUT was able to detect insecticides of high and low inhibitory power from the ng to μg range per zone. Due to high selectivity of enzyme inhibition, oxon impurities of thionophosphate standards were strongly detected, although only present in low traces. The exemplary application of HPTLC–EI (RLE) to apple juice and drinking water samples spiked with paraoxon (0.001 mg/L), parathion (0.05 mg/L) and chlorpyrifos (0.5 mg/L) resulted in mean recoveries between 71 and 112% with standard deviations of 2.0–18.3%.  相似文献   

13.
We studied the use of high-performance liquid chromatography (HPLC) with spectrofluorometric detection, using a solid-phase extraction for a simple, rapid and sensitive determination of plasma carvedilol levels in rats. Extracted aliquots were analyzed by HPLC, using a reversed-phase octadecyl silica column. The analytical mean recovery of carvedilol added to the blank plasma was 94.2%. The detection limit was 3.6 ng/ml in the plasma. The reproducibilities (C.V.) were 2.7–7.5% for the within-day assay, and 2.6–7.4% for the between-day assay, indicating that the method was effective for the determination of carvedilol plasma levels.  相似文献   

14.
A simple and sensitive spectrofluorimetric method has been developed and validated for the determination of oseltamivir phosphate (OST) in pharmaceutical preparations. The method is based on the reaction between oseltamivir phosphate and o‐phthalaldehyde in presence of 2‐mercapto‐ethanol in borate buffer, pH 10.8, to give a highly fluorescent product measured at 450 nm after excitation at 336 nm. The different experimental parameters affecting the development and stability of the reaction product were studied and optimized. The fluorescence intensity–concentration plot is rectilinear over the range 0.05–1.0 µg/mL, with a lower detection limit of 5 ng/mL and limit of quantitation of 16 ng/mL. The developed method was successfully applied to the analysis of the drug in its commercial capsules and suspension, mean recoveries of OST were 99.97 ± 1.67% and 100.17 ± 1.18%, respectively (n = 3). Statistical comparison of the results obtained by the proposed and comparison method revealed no significant difference in the performance of the two methods regarding accuracy and precision. The proposed method was further extended to in vitro determination of the studied drug in spiked human plasma as a preliminary investigation; the mean recovery (n = 3) was 98.68 ± 5.8%. A reaction pathway was postulated. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

15.
A flow injection system with chemiluminescence detection for the determination of asulam, enhancer of the system luminol–H2O2–horseradish peroxidase, is proposed. The method shows a moderate selectivity against other pesticides usually present in formulations of herbicides and in water. The procedure was applied to the determination of asulam in tap water samples and a recovery study was carried out in order to validate the method. The obtained results show acceptable recovery values (between 88.3 and 93.9%). The detection limit for asulam was 0.12 ng/mL. The precision of the method expressed as relative standard deviation was 1.55% (n = 8), at the 19 ng/mL level. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
A simple and reproducible HPTLC method for the determination of gymnemagenin (1) in Gymnema sylvestre has been developed. Components were separated on pre-coated silica gel 60 F254 plates with chloroform:methanol (9:1) and scanned using a densitometric scanner in the UV reflectance mode at 290 nm. Linearity of determination of 1 was observed in the range 4-10 microg. The average percentage recovery of 1 from an extract was 99.09 +/- 0.29, and the content of 1 in leaves of the title plant was 1.61% (dry weight).  相似文献   

17.
A high-performance thin-layer chromatographic (HPTLC) method for the assay of flurbiprofen in plasma is reported. The drug was extracted from acidified plasma with hexane–diethyl ether (80:20). The mobile phase composition was n-hexane–ethyl acetate–glacial acetic acid (60:30:10). Densitometric analysis of flurbiprofen was carried out at 247 nm. The calibration curves of flurbiprofen in methanol and in plasma were linear in the range 40–400 ng. The mean values of correlation coefficient, slope and intercept were 0.995±0.003, 0.075±0.002 and 4.39±0.05 for standard curves in methanol and 0.992±0.002, 0.066±0.007 and 3.40±0.72 for standard curves in plasma, respectively. The limit of quantitation for flurbiprofen in human plasma was 40 ng, and no interference was found from endogenous compounds. The recovery of flurbiprofen from human plasma using the described extraction procedure was about 87%. The coefficient of variation for within-day and between-day analyses was 2.53% and 3.96% for 200 ng and 1.76% and 2.30% for 400 ng flurbiprofen concentration, respectively. The method was utilized to monitor plasma concentration of flurbiprofen post administration of sustained release capsules in human patient volunteers.  相似文献   

18.
A simple high-performance liquid chromatographic method was developed for the determination of ranitidine in human plasma. Prior to analysis, ranitidine and the internal standard (metoprolol) were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M potassium dihydrogenphosphate–acetonitrile (88:12, v/v) adjusted to pH 6.5. Analysis was run at a flow-rate of 1.3 ml/min and at a detection wavelength of 229 nm. The method is sensitive with a detection limit of 1 ng/ml at a signal-to-noise ratio of 3:1, while the quantification limit was set at 15 ng/ml. The calibration curve was linear over a concentration range of 15–2000 ng/ml. Mean recovery value of the extraction procedure was about 90%, while the within-day and between-day coefficients of variation and percent error values of the assay method were all less than 15%.  相似文献   

19.
A simple high-performance liquid chromatographic method using ultraviolet detection was developed for the determination of metformin in human plasma. The method entailed direct injection of the plasma sample after deproteination using perchloric acid. The mobile phase comprised 0.01 M potassium dihydrogen orthophosphate (pH 3.5) and acetonitrile (60:40, v/v). Analyses were run at a flow-rate of 1.0 ml/min with the detector operating at a detection wavelength of 234 nm. The method is specific and sensitive, with a quantification limit of approximately 60 ng/ml and a detection limit of 15 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery value was about 97%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 8%. The calibration curve was linear over a concentration range of 62.5–4000 ng/ml.  相似文献   

20.
A simple procedure for determining trace phthalic acid monoesters (PAMs) in sediments/soils was developed. The method used ultrasonic extraction, silylation derivatization, and GC-MS. After ultrasonic extraction, the supernatants were reextracted with dichloromethane, silylated, and did not require further clean-up before GC-MS analysis. Effects of parameters, such as extraction solvents, pH of water as extraction solvent and sediment/soil properties, on the recovery of PAMs were studied. Five sediments from Tianjin city and one red soil from Jiangxi province were used. The results showed that organic carbon (OC) content played an important role in the recovery of PAMs. The optimal extraction solvent for sediments/soils with >1% of OC content and high CEC was 0.01 M HCl aqueous solution and pure water was better for sediments/soils with <1% of OC content. In 5 g sediment/soil sample (dry weight), the method detection limit (MDL) was below 0.04 ng/g for mono-n-butyl phthalate (MBP) and 0.02 ng/g for mono-(2-ethylhexyl)-phthalate (MEHP). Average recoveries of MBP and MEHP were 81.6%?105.2% and 76.0%?95.6%, respectively, with relative standard deviations ≤ 6.6%. MBP and MEHP in the sediment and soil samples studied were detected at levels of 9.2–57.1 and 13.0–166.7 ng/g, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏