首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Tetrahydrocannabinol (THC) is an important psychoactive ingredient in marijuana, which is the most widely used illegal recreational drug in the USA. Since it is generally smoked, the constituents of the plant material, as well as THC may be present in oral fluid specimens collected for the purposes of drug testing. We present an analytical procedure for the simultaneous determination of the pyrolytic precursor Delta(9)-tetrahydrocannabinolic acid A, tetrahydrocannabinol, cannabinol and cannabidiol in human oral fluid specimens using gas chromatography mass spectrometry (GC/MS). Solid phase extraction and GC/MS/EI with selected ion monitoring were used, and the linearity of the method ranged from 0-16 ng/mL of neat oral fluid. The recovery of the cannabinoids from the collection pad into the transportation buffer was greater than 70% for all cannabinoids tested at 4 ng/mL, and the intra- and inter-day precision was less than 10.3 and 15.2% for all analytes. The stability of the drugs in oral fluid and of the extracted derivatives was investigated. The procedure was applied to oral fluid specimens taken from habitual marijuana smokers. We have previously reported the presence of the metabolite 11-nor-Delta(9)-tetra-hydrocannabinol-9-carboxylic acid in oral fluid, but this is the first report of the plant constituent 2-carboxy-THC being detected in saliva.  相似文献   

2.
Phytoestrogens (isoflavones and lignans) are of increasing interest due to their potential to prevent certain types of complex diseases. However, epidemiological evidence is needed on the levels of phytoestrogens and their metabolites in foods and biological fluids in relation to risk of these diseases. We report an assay for phytoestrogens which is sensitive, accurate, and uses low volumes of sample. Suitable for epidemiological studies, the assay consists of a simple sample preparation procedure and has been developed for the analysis of five isoflavones (daidzein, O-desmethylangolensin, equol, genistein, and glycitein) and two lignans (enterodiol and enterolactone), which requires only 200 microl of urine and utilizes one solid-phase extraction stage for sample preparation prior to derivatization for GC/MS analysis. Limits of detection were in the region 1.2 ng/ml (enterodiol) to 5.3ng/ml (enterolactone) and the method performed well in the UK Government's Food Standards Agency-sponsored quality assurance scheme for phytoestrogens. For the first time, average levels of all the above phytoestrogens were measured in samples of urine collected from a free living population sample of women. Results show a large range in both the amount and the type of phytoestrogens excreted.  相似文献   

3.
A sensitive high-performance liquid chromatographic (HPLC) method with ultraviolet absorption detection (292 nm) was developed and validated for the determination of the new phosphodiesterase V inhibitor, DA-8159 (DA), in human plasma and urine. A single step liquid-liquid extraction procedure using ethyl ether was performed to recover DA and the internal standard (sildenafil citrate) from 1.0 ml of biological matrices combined with 200 microl of 0.1M sodium carbonate buffer. A Capcell Pak C18 UG120 column (150 mm x 4.6 mm I.D., 5 microm) was used as a stationary phase and the mobile phase consisted of 30% acetonitrile and 70% 20mM potassium phosphate buffer (pH 4.5) at a flow rate of 1.0 ml/min. The lower limit for quantification was 5 ng/ml for plasma and 10 ng/ml for urine samples. Within- and between-run accuracy and precision were < or =15 and < or =10%, respectively, in both plasma and urine samples. The recovery of DA from human plasma and urine was greater than 70%. Separate stability studies showed that DA is stable under the conditions of analysis. This validated assay was used for the pharmacokinetic analysis of DA during a phase I, rising dose study.  相似文献   

4.
An in-situ supercritical fluid extraction (SFE) and chemical derivatization (ChD) procedure followed by gas chromatography–isotope dilution mass spectrometry (GC–MS) for the determination of amphetamines in urine is described and evaluated. While using celite as the SFE wet-support, the one-pot sample pretreatment procedure also employs ammonium water to alkalize the urine matrix that contains protonated amphetamine (AP) and methamphetamine (MA). The mean recoveries achieved by simultaneous SFE–ChD, i.e., 95% (RSD=3.8%) for AP and 89% (RSD=4.0%) for MA, are significantly better than the corresponding overall recoveries obtained upon stepwise SFE–ChD, suggesting the unreacted trifluoroacetic anhydride (TFA) in the former procedure has strengthened the extracting power of CO2 fluid as has been evidenced by a control test. As to GC–MS analysis, the optimal qualitative ions and quantitative ions of the respective analytes were determined via a rigorous evaluation process. Thus, the regression calibration curves for AP and MA in urine are linear within 100∼50 000 ng/ml, with correlation coefficients typically exceeding 0.999. The limits of detection determined by two methods for AP and MA vary from 19 to 50 ng/ml, and limits of quantitation from 21 to 100 ng/ml. Precisions calculated for the triplicate analyses of AP and MA in a 500-ng/ml spiked control, two real-case samples and two quasi real-case samples, respectively, using regression calibration are typically below 10%. The method is simple and reliable. It may serve as an alternative to the existing confirmatory protocol for forensic urine drug testing.  相似文献   

5.
In this paper, the possibility of using a multiple ionization mode approach of GC/MS was developed for the simultaneous hair testing of common drugs of abuse in Asia, including amphetamines (amphetamine, AP; methamphetamine, MA; methylenedioxy amphetamine, MDA; methylenedioxy methamphetamine, MDMA; methylenedioxy ethylamphetamine, MDEA), ketamine (ketamine, K; norketamine, NK), and opiates (morphine, MOR; codeine, COD; 6-acetylmorphine, 6-AM). This strategy integrated the characteristics of gas chromatography-mass spectrometry (GC-MS) using electron impact ionization (EI) and negative chemical ionization (NCI). Hair samples (25 mg) were washed, cut, and incubated overnight at 25 degrees C in methanol-trifluoroacetic acid (methanol-TFA). The samples were extracted by solid phase extraction (SPE) procedure, derivatized using heptafluorobutyric acid anhydride (HFBA) at 70 degrees C for 30 min, and the derivatives analyzed by GC-MS with EI and NCI. The limit of detection (LOD) with GC/EI-MS analysis obtained were 0.03 ng/mg for AP, MA, MDA, MDMA, and MDEA; 0.05 ng/mg for K, NK, MOR, and COD; and 0.08 ng/mg for 6-AM. The LOD of GC/NCI-MS analysis was much lower than GC/EI-MS analysis. The LOD obtained were 30 pg/mg for AP and MDA in GC/EI-MS and 2 pg/mg in GC/NCI-MS. Therefore, the sensitivity of AP and MDA in GC/NCI-MS was improved from 15-fold compared with EI. The sensitivity of AP, MA, MDA, MDMA, MDEA, MOR, and COD was improved from 15- to 60-fold compared with EI. In addition, the sensitivity of 6-AM increased 8-fold through selection of m/z 197 for the quantitative ion. Moreover, K and NK could dramatically improve their sensitivity at 200- and 2000-fold. The integration of GC/EI-MS and GC/NCI-MS can obtain the high sensitivity and complementary results of drugs of abuse in hair. Six hair samples from known drug abusers were examined by this new strategy. These results show that integrating the characteristics of GC/EI-MS and GC/NCI-MS were not only enhancement of the sensitivity but also avoid wrong results and wrong interpretations of correct results.  相似文献   

6.
The aim of this work was to develop and validate a method for analysing amphetamine-type stimulants (ATSs) and their metabolites in plasma, urine and bile by liquid chromatography with a strong cation-exchange column-tandem mass spectrometry, and to apply it to the pharmacokinetic study of ATSs. 3,4-Methylenedioxymethamphetamine, methamphetamine, ketamine and their main metabolites, 4-hydroxy-3-methoxymethamphetamine, 3,4-methylenedioxyamphetamine, p-hydroxymethamphetamine, amphetamine and norketamine, were simultaneously quantified by the new method (50-5000 ng/ml). The coefficients of variation and the percent deviations for the eight compounds were in the range of 0.2 to 5.3% and -9.4 to +12.8%, respectively. The recoveries were over 90% in all biological samples tested. This method was effective for the separation and the identification of ATSs and their main metabolites having amine moieties in plasma, urine and bile, and was applicable to pharmacokinetic analysis of methamphetamine, ketamine and their main metabolites in biological samples. This analytical method should be useful for the pharmacokinetic analysis of ATSs.  相似文献   

7.
We have developed and validated a sensitive and selective assay for the quantification of paclitaxel and its metabolites 6α,3′-p-dihydroxypaclitaxel, 3′-p-hydroxypaclitaxel and 6α-hydroxypaclitaxel in plasma, tissue, urine and faeces specimens of mice. Tissue and faeces were homogenized (approximately 0.1–0.2 g/ml) in bovine serum albumin (40 g/I) in water, and urine was diluted (1:5, v/v) in blank human plasma. Sample pretreatment involved liquid-liquid extraction of 200–1000 μl of sample with diethyl ether followed by automated solid-phase extraction using cyano Bond Elut column. 2′-Methylpaclitaxel was used as internal standard. The overall recovery of the sample pretreatment procedure ranged from 76 ot 85%. In plasma, the lower limit of detection (LOD) and the lower limit of quantitation (LLQ) are 15 and 25 ng/ml, respectively, using 200 μl of sample. In tissues, faeces and urine the LLQs are 25–100 ng/g, 125 ng/g and 25 ng/ml, respectively, using 1000 μl (faeces: 200 μl) of homogenized or diluted sample. The concentrations in the various biological matrices, for validation procedures spiked with known amounts of the test compounds, are read from calibration curves constructed in blank human plasma in the range 25–100 000 ng/ml for paclitaxel and 25–500 ng/ml for the metabolites. The accuracy and precision of the assay fall within the generally accepted criteria for bio-analytical assays.  相似文献   

8.
Analysis of Delta(9)tetrahydrocannabinol (Delta(9)THC) and its metabolites in biological samples is of great relevance for forensic purposes. In the case of oral fluid (OF), the analysis should determine Delta(9)THC, whereas in urine, it detects the inactive metabolite tetrahydrocannabinol carboxylic acid (THC-COOH). Most laboratories analyze Delta(9)THC in such samples using GC-MS methods, but these procedures are time-consuming and involve unavoidable previous extraction and derivatization. No data is yet available on the application of liquid chromatography-mass-spectrometry to detect Delta(9)THC in oral fluid. We report a validation method in which the Delta(9)THC is isolated from oral fluid by a simple liquid-liquid extraction with hexane and subsequently analyzed by liquid chromatography-mass-spectrometry. The method here reported for the determination of Delta(9)THC in oral fluid only requires 200 microl of sample and achieves limits of detection of 2 ng/ml, and has been used to analyze oral fluid samples collected from current drug users.  相似文献   

9.
Gamma-hydroxybutyric acid (GHB) is a substance naturally present within mammal species. Properties of a neurotransmitter or neuromodulator are generally suggested for this substance. GHB is therapeutically used as an anaesthetic, but can be used for criminal offences (date-rape drug). It appears that the window of detection of GHB is very short in both blood and urine, and therefore its presence is very difficult to prove after a rape case. Twenty microl of blood or urine were pipetted into a glass tube, followed by 20 microl GHB-d(6) and 45 microl acetonitrile. After vortexing and efficient centrifugation, the supernatant was collected and evaporated to dryness. The residue was derivatized with BSTFA+1% TMCS for 20 min at 70 degrees C. After injection on a 30-m HP5 MS capillary column, GHB (m/z 233, 204 and 147) and GHB-d(6) (m/z 239) were identified by mass spectrometry. The procedure was linear from 1 to 200 mg/l for both blood and urine. Precisions were in the range 4 to 11%. The method appears simple, specific and rapid as an accurate result can be obtained within 1 h.  相似文献   

10.
This study was carried out qualitatively and quantitatively to investigate the presence and the concentrations of anabolic steroids in urine collected from orally administered humans. Microanalysis of conjugated steroids by gas chromatography and mass spectrometry (GC/MS) has been carried out. Following oral administration three major metabolites of anabolic steroid drugs have been detected and partially characterized. The six steroids can be analysed at the same time in 17 min. The lower detection limit was 10 ng/ml in 5 ml of urine. The conjugated steroids from urine were centrifuged to 2,430g for 10 min, the supernatant solution passed through Amberlite XAD-2 column and the steroids eluted fraction esterified by using MSTFA and TMSI. The rate of metabolism and urinary excretion seem to be reasonably fast.  相似文献   

11.
A direct and simple procedure for the determination of 4-methylpropranolol, a specific beta-adrenergic receptor blocking agent, in biological fluids was developed. The method was based on the measurement of the nonprotected fluid room-temperature phosphorescence of the drug. This technique enables us to determine analytes in complex matrices without the need for a tedious prior separation process. The appropriate experimental conditions to obtain suitable reproducibility and maximum phosphorescence signal, when sodium sulfite is used to eliminate the oxygen from the solution and when potassium iodide is used as heavy atom, were studied. The optimum concentration of KI was 3.2 M. The optimization of Na(2)SO(3) (7.0 x 10(-3) M) and the accurate value of pH (10.88) were determined using a simplex as the method of optimization. A sodium carbonate-hydrogen carbonate buffer solution (5.0 x 10(-2) M) was used to adjust the value of pH. The delay time (124 micros), gate time (206 micros), and time between flashes (5 ms) were also optimized using a simplex. Under the above conditions, the maximum signal of phosphorescence appears instantly once the sample has been prepared, and the intensity was measured at lambda(ex) = 300 nm and lambda(em) = 537 nm, in the concentration range 25-500 ng/ml. Overall least-squares regression was used to find the straight line that fit the experimental data. The detection limit according to the error propagation theory was 6.2 ng/ml and the detection limit calculated as proposed by C. A. Clayton et al. (1987, Anal. Chem. 59, 2506) was 11.7 ng/ml. The repeatability was studied using 10 solutions of 200 ng/ml 4-methylpropranolol; if error propagation theory was assumed, the relative error was 1.78% and the standard deviation for replicate samples was 3.5 ng/ml. This method was successfully applied to the determination of 4-methylpropranolol in urine, serum, and cerebrospinal fluid, with recoveries of 99.3 +/- 0.5% in the case of urine, 99.8 +/- 0.2% for serum, and 101.5 +/- 1.5% for cerebrospinal fluid.  相似文献   

12.
An assay for cadmium in whole blood and urine using deuterium background-correction electrothermal atomic absorption spectroscopy (D(2)-ETAAS) was developed. Cadmium (in a 1- to 2-ml sample) was bound to 15 mg anion-exchange resin, interfering ions were removed in a 2-ml Bio-Spin column, and cadmium was extracted into 100 microl 1M nitric acid for analysis. Cadmium in the sample extract was concentrated 7-fold for blood and 10-fold for urine over the starting material. These steps produced cadmium atomic absorption traces with high signal to background ratios and allowed analysis against aqueous standards. At approximately 0.1 ng Cd/ml, mean intra- and interassay coefficients of variation were 11-12%. Cadmium recovery for 0.1 to 0.6 ng added cadmium was 107+/-4% for blood and 94+/-4% for urine (mean+/-SE, n=3). The mean detection limit (mean + 3 x SD of blank) was 0.008 ng/ml for blood and 0.003 ng/ml for urine. Samples from "unexposed" animals including humans ranged from 0.051+/-0.000 to 0.229+/-0.035 ng/ml. Values were approximately 10-fold lower than those obtained by the method of Stoeppler and Brandt using Zeeman background-correction ETAAS. This new high-sensitivity, low-volume assay will be useful for epidemiological studies, even those involving children, and will provide a means to help determine the contribution of cadmium to disease incidence in the general population.  相似文献   

13.
Analytical procedures for the determination of meperidine, tramadol and oxycodone in oral fluid have been developed and validated using gas chromatography-mass spectrometry (GC/MS) following initial screening with enzyme linked immunosorbent assay (ELISA). The oral fluid samples were collected using the Quantisal device, and any drugs present were quantified using mixed mode solid-phase extraction and electron impact GC/MS. For confirmation, three ions were monitored and two ion ratios determined, which were within 20% of those of the known calibration standards. The limits of quantitation were 10 ng/mL; the intra-day precision of the assays (n=5) was 2.33%, 1.00% and 7.61%; inter-day precision 2.48%, 2.44% and 5.8% (n=10) for meperidine, tramadol and oxycodone, respectively. The percentage recovery of the drugs from the collection pads was 86.7%, 87.7% and 96.6%, respectively (n=6). The methods were applied to specimens obtained during research studies in the USA.  相似文献   

14.
Asymmetric dimethylarginine (ADMA; N(G),N(G)-dimethyl-L-arginine) is the most important endogenous inhibitor of nitric oxide synthase and a potential risk factor for cardiovascular diseases. This article describes a gas chromatographic-tandem mass spectrometric (GC-tandem MS) method for the accurate quantification of ADMA in human plasma or serum and urine using de novo synthesized [2H(3)]-methyl ester ADMA (d(3)Me-ADMA) as the internal standard. Aliquots (100 microl) of plasma/serum ultrafiltrate or native urine and of aqueous solutions of synthetic ADMA (1 microM for plasma and serum; 20 microM for urine) are evaporated to dryness. The residue from plasma/serum ultrafiltrate or urine is treated with a 100 microl aliquot of 2M HCl in methanol, whereas the residue of the ADMA solution is treated with a 100 microl aliquot of 2M HCl in tetradeuterated methanol. Methyl esters are prepared by heating for 60 min at 80 degrees C. After cooling to room temperature, the plasma or urine sample is combined with the d(3)Me-ADMA sample, the mixture is evaporated to dryness, the residue treated with a solution of pentafluoropropionic (PFP) anhydride in ethyl acetate (1:4, v/v) and the sample is incubated for 30 min at 65 degrees C. Solvent and reagents are evaporated under a stream of nitrogen gas, the residue is treated with a 200 microl aliquot of 0.4M borate buffer, pH 8.5, and toluene (0.2 ml for plasma, 1 ml for urine). Reaction products are extracted by vortexing for 1 min, the toluene phase is decanted, and a 1 microl aliquot is injected into the GC-tandem MS instrument. Quantitation is performed by selected reaction monitoring (SRM) of the common product ion at m/z 378 which is produced by collision-induced dissociation of the ions at m/z 634 for endogenous ADMA and m/z 637 for d(3)Me-ADMA. In plasma and urine of healthy humans ADMA was measured at concentrations of 0.39+/-0.06 microM (n=12) and 3.4+/-1.1 micromol/mmol creatinine (n=9), respectively. The limits of detection and quantitation of the method are approximately 10 amol and 320 pM of d(3)Me-ADMA, respectively.  相似文献   

15.
Sensitive assay for determining plasma tenofovir concentrations by LC/MS/MS   总被引:1,自引:0,他引:1  
An LC/MS/MS assay for the determination of tenofovir (TNF) was developed and validated for use with the EDTA anticoagulated human plasma matrix. Heparin-treated plasma and serum matrices were also validated. After addition of adefovir as an internal standard, trifluoroacetic acid was used to produce a protein-free extract. Chromatographic separation was achieved with a Polar-RP Synergi, 2.0 mm x 150 mm, reversed-phase analytical column. The mobile phase was 3% acetonitrile/1% acetic acid, aq. Detection of TNF and the internal standard was achieved by ESI MS/MS in the positive ion mode using 288/176 and 274/162 transitions, respectively. The method was linear from 10 to 750 ng/ml with a minimum quantifiable limit of 10 ng/ml when 250 microl aliquots were analyzed. The usefulness of this LC/MS/MS method to routinely monitor plasma concentrations of TNF was demonstrated along with its ability to assist in the performance of pharmacokinetic studies.  相似文献   

16.
A simple, rapid and sensitive method for determination of trichloroethylene (TCE) in rat blood, liver, lung, kidney and brain, using headspace solid-phase microextraction (HS-SPME) and gas chromatography/mass spectrometry (GC/MS), is presented. A 100-microm polydimethylsiloxane (PDMS) fiber was selected for sampling. The major analytical parameters including extraction and desorption temperature, extraction and desorption time, salt addition, and sample preheating time were optimized for each of the biological matrices to enhance the extraction efficiency and sensitivity of the method. The lower limits of quantitation for TCE in blood and tissues were 0.25ng/ml and 0.75ng/g, respectively. The method showed good linearity over the range of 0.25-100ng TCE/ml in blood and 0.75-300ng TCE/g in tissues, with correlation coefficient (R(2)) values higher than 0.994. The precision and accuracy for intra-day and inter-day measurements were less than 10%. The relative recoveries of TCE respect to deionized water from all matrices were greater than 55%. Stability tests including autosampler temperature and freeze and thaw of specimens were also investigated. This validated method was successfully applied to study the toxicokinetics of TCE following administration of a low oral dose.  相似文献   

17.
A sensitive and reproducible method is described for the analysis of trichloroacetic acid in urine and 1,1,1-trichloroethane in blood using dynamic headspace GC/MS. Samples were analyzed using the soil module of a modified purge and trap autosampler to facilitate the use of disposable purging vessels. Coefficients of variation were below 3.5% for both analytes, and response was linear in the range of 0.01-7.0 microg/ml for trichloroacetic acid and 0.9 ng/ml-2.2 microg/ml for 1,1,1-trichloroethane. Attempts at using dynamic headspace for the analysis of trichloroethanol in urine were unsuccessful.  相似文献   

18.
In the present study, we simultaneously measured several polyols, such as adonitol, arabitol, dulcitol, glucose, myo-inositol, mannitol, sorbitol, and xylitol, in urine by gas chromatography/mass spectrometry-positive chemical ionization. We also examined possible relationship between the levels of these metabolites and age in normal individuals. In order to proceed to its quantification by GC/MS, 200 microL of a urine sample were diluted with 3 ml of distilled water, lyophilized, acetylated, and then analyzed them. Using this method, we were able to quantify as little as 0.5-1.0 ng/microL, and we made the calibration curves to be linear from 0.25 to 250 ng/microL (r(2)>0.991). Analytical recoveries were over 89.4%, and the inter-day and intra-day variability for accuracy and reproducibility was less than 20%. In the normal urine sample, the levels of polyols were gender-differentiated and age-related. This simple GC/MS method is sensitive and allows the measurement of wide ranges of polyols using small amounts of urine. We conclude that the quantitation of urinary polyols using GC/MS appears to be a clinically useful method for assessing polyol-pathway activity.  相似文献   

19.
A rapid, selective and highly sensitive reversed-phase high-performance liquid chromatography (HPLC) method was developed for the determination of levosulpiride, 5-(aminosulfonyl)-N-[(1-ethyl-2-pyrrolidinyl)methyl]-2-methoxy benzamide, in human serum and urine. The method involved the extraction with a dichloromethane followed by back-extraction into 0.025 M sulfuric acid. HPLC analysis was carried out using reversed-phase isocratic elution with a Luna C(18)(2) 5 microm column, a mobile phase of acetonitrile-0.01 M potassium hydrogen phosphate (30:70, v/v, adjusted to pH 8.5 with triethylamine), and a fluorescence detector with excitation at 300 nm and emission at 365 nm. The chromatograms showed good resolution and sensitivity and no interference of human serum and urine. The calibration curves were linear over the concentration range 0.25-200 ng/ml for serum and 0.2-20 microg/ml for urine with correlation coefficients greater than 0.997. Intra- and inter-day assay precision and accuracy fulfilled the international requirements. The mean absolute recovery for human serum was 89.8+/-3.7%. The lower limits of quantitation in human serum and urine were 0.25 ng/ml and 0.2 microg/ml, respectively, which were sensitive enough for pharmacokinetic studies. Stability studies showed that levosulpiride in human serum and urine was stable during storage, or during the assay procedure. This method was successfully applied to the study of pharmacokinetics of levosulpiride in human volunteers following a single oral administration of levosulpiride (25 mg) tablet.  相似文献   

20.
A rapid, accurate and sensitive method has been developed and validated for the quantitative simultaneous determination of four cephalosporins, cephalexin and cefadroxil (first-generation), cefaclor (second-generation) and cefataxim (third-generation), in pharmaceuticals as well as in human blood serum and urine. A Spherisorb ODS-2 250 x 4-mm, 5-microm analytical column was used with an eluting system consisting of a mixture of acetate buffer (pH 4.0)-CH(3)OH 78-22% (v/v) at a flow-rate 1.2 ml/min. Detection was performed with a variable wavelength UV-Vis detector at 265 nm resulting in limit of detection of 0.2 ng for cefadroxil and cephalexin, but only 0.1 ng for cefotaxime and cefaclor per 20-microl injection. Hydrochlorothiazide (HCT) (6-chloro-3,4-dihydro-7 sulfanyl-2H-1,2,4-benzothiadiazine-1-1-dioxide) was used as internal standard at a concentration of 2 ng/microl. A rectilinear relationship was observed up to 8, 5, 12 and 35 ng/microl for cefadroxil, cefotaxime, cefaclor, cephalexin, respectively. Analysis time was less than 7 min. The statistical evaluation of the method was examined by means of within-day repeatability (n=8) and day-to-day precision (n=9) and was found to be satisfactory with high accuracy and precision. The method was applied to the determination of the cephalosporins in commercial pharmaceuticals and in biological fluids: human blood serum after solid-phase extraction and urine simply after filtration and dilution. Recovery of analytes in spiked samples was in the range from 76.3 to 112.0%, over the range of 1-8 ng/microl.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号