首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The whitemouth croaker produces two different sounds using extrinsic sonic muscles: (1) male advertisement calls during the spawning season and (2) disturbance calls, produced by both sexes. The advertisement call, related to courtship, was recorded in the field and from two marked spawning males of 28 and 30.5 cm LT in the laboratory. It consists of individual pulses with average durations of 19.7 ms and 17.8 ms for the two males respectively, interpulse intervals of 496 ms and 718 ms, and dominant frequencies of 280 Hz and 316 Hz. Pulses are emitted in bouts of one to three min duration. Disturbance calls consist of a burst of pulses produced at short intervals, and the pulse duration, interpulse interval and dominant frequency of the pulses average 19.8 ms, 17.1 ms, and 363 Hz, respectively. Dominant frequency and interpulse interval decrease and pulse duration increases with fish size. Sound characteristics change markedly in young of the year individuals (lower than 25 cm LT) after which they appear to stabilize. Higher dominant frequency in the advertisement than in the disturbance call and the relationship of dominant frequency to pulse duration suggest that dominant frequency is determined as a forced response to muscle contraction parameters rather than by the natural frequency of the swimbladder.  相似文献   

2.
The interception of a pheromone filament induces flying moths to surge briefly nearly straight upwind; in the absence of pheromone moths cease upwind progress and zigzag crosswind. We tested males of the almond moth, Cadra cautella (Lepidoptera, Pyralidae), in a low-turbulence wind tunnel in wind velocities of 20, 40 and 80 cm s−1. A mechanical pulse generator was set to produce plumes either with same pheromone pulse frequency (pulse generation frequency of 2.9 Hz, interpulse distances from 7 cm to 28 cm) or plumes with same interpulse distance across the three wind velocities (interpulse distance of 14 ± 2 cm, pulse generation frequency of 1.7–5.0 Hz). In plumes of similar pulse frequency, the faster the speed of the wind the slower the ground speed of flight. However, in plumes of similar interpulse distance, ground speed remained relatively constant independent of the wind speed. A `realized' frequency of pulse interception for males flying along the various combinations of pulse frequencies and wind velocities was calculated using the males' average airspeed and the spatial distribution of pheromone pulses in the plume. Realized frequency of pulse interception ranged from 1.3- to 3.0-fold higher than the frequency of pulse generation. The flight tracks of males reflected the regime of realized pulse interception. These results suggest that upwind flight orientation of male C. cautella to pheromone in different wind velocities is determined by the flux of filament encounter. Accepted: 3 September 1997  相似文献   

3.
普氏蹄蝠(Hipposideros pratti)回声定位声波、形态及捕食策略   总被引:7,自引:0,他引:7  
研究了普氏蹄蝠(Hipposideros pratti)不同状态(飞行,悬挂)下的回声定位声波特征,形态特征和生态特征(捕食策略,捕食地和食物类型)。结果表明,普氏蹄蝠的回声定位声波为CF-FM型,在不同状态下,主频率有一定的差异,飞行状态的主频率略低于悬挂状态,表明普氏蹄蝠是利用多谱勒补偿效应来适应飞行速度引起的主频率变化,以进行准确的定位和有效的捕食;同时飞行状态下声脉冲时间,声脉冲间隔时间及FM带宽略低于悬挂状态,而声脉冲重复率和能率环略主于悬挂状态,表明普氏蹄蝠在不同状态下利用不同特征的声波进行捕食,由回声定位声波推断和野外观察可知,普氏蹄蝠可能在树冠周围以盘旋方式(在昆虫高峰期)或以捕蝇器式(在昆虫高峰期这后)捕食中等偏大的振翅昆虫(如甲虫)。  相似文献   

4.
This work describes the use of low-voltage (0.5 - 5 V) pulsed electric fields to prevent Pseudomonas aeruginosa biofilm development. Interdigitated electrodes (IDEs) with 29-mum spacing between 22-mum-wide electrodes, were used as a platform where the effect of localised, high-strength electric fields could be tested. Alternating current, square-wave pulses were applied to the IDEs in 1 sec intervals. A two-level, three-variable factorial design experiment was used to detect the effects of applied voltage, frequency, and pulse duty ratio (i.e. percentage of pulsing time over one cycle) on the inhibition of biofilm formation. The observations indicated that a pulse configuration of 1% duty ratio, 5 V, and 200 Hz frequency reduced the area of the electrodes covered by biofilm by 50%. In general, the application of low-duty ratio pulses had a positive effect on preventing biofouling. Comparatively, frequency and applied voltage were observed to have less influence on biofouling.  相似文献   

5.
Ewes (N = 32) were bled every 2 h from 5 days before expected oestrus until the end of oestrus. Plasma concentrations were determined for progesterone to monitor luteal activity and for the prostaglandin F-2 alpha (PGF-2 alpha) metabolites, 15-keto-13,14-dihydro-PGF-2 alpha and 11-ketotetranor-PGF to determine uterine synthesis and release of PGF-2 alpha. Most of the variation in cycle length was associated with the time of onset of luteolysis, the timing of events after luteolysis being constant and not related to cycle length. The time of occurrence of the first PGF-2 alpha pulse and the interval between this pulse and the start of luteolysis were the two main determinants responsible for oestrous cycle length. Several PGF-2 alpha pulses with interpulse intervals of 15.9 h occurred before the onset of functional luteolysis compared with 7.7 h for pulses associated with luteolysis. The numbers of PGF-2 alpha pulses and interpulse intervals were similar for oestrous cycles of different lengths. While a gradual decline in progesterone concentrations was observed before functional luteolysis in the ewes with longer cycles, this did not appear to be an integral part of the stimulus which initiates the pulse frequency of PGF-2 alpha required for luteolysis. We therefore suggest that differences in oestrous cycle length in the ewe are determined by the time of the onset of PGF-2 alpha pulsatile release, and especially by the time of increased pulse frequency.  相似文献   

6.
研究了普氏蹄蝠(Hipposideros pratti)不同状态(飞行、悬挂)下的回声定位声波特征、形态特征和生态特征(捕食策略、捕食地和食物类型).结果表明,普氏蹄蝠的回声定位声波为CFFM型,在不同状态下,主频率有一定的差异,飞行状态的主频率略低于悬挂状态,表明普氏蹄蝠是利用多谱勒补偿效应来适应飞行速度引起的主频率变化,以进行准确的定位和有效的捕食;同时飞行状态下声脉冲时间、声脉冲间隔时间及FM带宽略低于悬挂状态,而声脉冲重复率和能率环略高于悬挂状态,表明普氏蹄蝠在不同状态下利用不同特征的声波进行捕食.由回声定位声波推断和野外观察可知,普氏蹄蝠可能在树冠周围以盘旋方式(在昆虫高峰期)或以捕蝇器式(在昆虫高峰期之后)捕食中等偏大的振翅昆虫(如甲虫).  相似文献   

7.
Zhang Y  Ding J  Duan W  Fan W 《Bioelectromagnetics》2005,26(5):406-411
The influence of low frequency (50 Hz repetition rate) pulsed electromagnetic field (EMF) on PC12 cell neurite outgrowth in vitro was investigated in this study. We studied the percentage of neurite bearing cells, average length of neurites, and directivity of neurite outgrowth in PC12 cells cultured for 96 h in the presence of nerve growth factor (NGF). PC12 cells were exposed in one incubator to pulsed EMF at 1.36 mT (peak value) generated by a pair of Helmholtz coils, and the control samples were placed in another identical incubator. We found that the pulse duty cycle had significant effect on neurite outgrowth. Low (10%) pulse on-time significantly inhibited the percentage of neurite bearing cells, but at the same time increased the average length of neurites, while 100% on-time (DC) had exactly the opposite effects. Furthermore, we found that neurites were prone to extend along the direction of pulsed EMF with 10% pulse on-time. Our studies show that neurite outgrowth in PC12 cells is sensitive to the pulse duty and this sensitivity was associated with NGF concentration.  相似文献   

8.
Muscle fatigue may be a precursor to workplace musculoskeletal disorders, with the low back resulting in the most frequently injured body part. Work/rest ratios have an effect on fatigue due to the amount of rest allowance provided following muscle contraction. This study explored various work/rest ratios by electrically stimulating rat medial longissimus muscles. A 3 V stimulus with 0.2 ms pulse duration was applied at a frequency of 30 Hz. There were four stimulation groups consisting of the following duty cycles (DC) and cycle times (CT): DC25%:CT20s, DC25%:CT280s, DC75%:CT20s, and DC75%:CT180s. Muscle fatigue was measured as a decrease in M-wave amplitude and area, and an increase in M-wave duration. The results indicated that fatigue occurred immediately in each of the groups. The higher duty cycle and shorter cycle time group resulted in significantly greater fatigue than the lower duty cycle and longer cycle time group, as measured by increased M-wave amplitude and area. A longer M-wave duration was observed in the high duty cycle long cycle time group. This suggests that the combination of low duty cycle and long cycle times leads to less fatigue. In high duty cycle scenarios, short cycle times result in less fatigue.  相似文献   

9.
Because of apparent reproductive isolation between Northern and Southern hemisphere populations of the black drum Pogonius cromis, we tested the hypothesis that advertisement calls from a southern population would differ from known calls of North American populations. Additionally, we quantified disturbance and advertisement calls, their changes with fish size and sex, not previously examined in this species. Unlike most sciaenids, both sexes of P. cromis possess robust sonic muscles, and both produce disturbance calls when handled. However, only males produce an advertisement call used in courtship. The disturbance call consists of a variable train of short-duration pulses (average 23?ms). The duration, interpulse interval, and dominant frequency of pulses are similar in males and females and change developmentally: pulse duration and interpulse interval increase and dominant frequency decreases with fish size. Advertisement calls, recorded in the field and in captivity, are long-duration (average 184?ms) and tonal. Based on variation in fundamental frequency, which decreases with fish size, field choruses are composed of different-sized individuals. The duration of advertisement calls, about a third of those from Florida populations, suggests genetic differentiation between northern and southern populations.  相似文献   

10.
Neuromodulation applications of nanosecond electric pulses (nsEP) are hindered by their low potency to elicit action potentials in neurons. Excitation by a single nsEP requires a strong electric field which injures neurons by electroporation. We bypassed the high electric field requirement by replacing single nsEP stimuli with high-frequency brief nsEP bursts. In hippocampal neurons, excitation thresholds progressively decreased at nsEP frequencies above 20–200 kHz, with up to 20–30-fold reduction at sub-MHz and MHz rates. For a fixed burst duration, thresholds were determined by the duty cycle, irrespective of the specific nsEP duration, rate, or number of pulses per burst. For 100-μs bursts of 100-, 400-, or 800-ns pulses, the threshold decreased as a power function when the duty cycle exceeded 3–5 %. nsEP bursts were compared with single “long” pulses whose duration and amplitude matched the duration and the time-average amplitude of the burst. Such pulses deliver the same electric charge as bursts, within the same time interval. High-frequency nsEP bursts excited neurons at the time-average electric field 2–3 times below the threshold for a single long pulse. For example, the excitation threshold of 139 ± 14 V/cm for a single 100-μs pulse decreased to 57 ± 8 V/cm for a 100-μs burst of 100-ns, 0.25-MHz pulses (p < 0.001). Applying nsEP in bursts reduced or prevented the loss of excitability in multiple stimulation attempts. Stimulation by high-frequency nsEP bursts is a powerful novel approach to excite neurons at paradoxically low electric charge while also avoiding the electroporative membrane damage.  相似文献   

11.
Abstract

This work describes the use of low-voltage (0.5 – 5 V) pulsed electric fields to prevent Pseudomonas aeruginosa biofilm development. Interdigitated electrodes (IDEs) with 29-μm spacing between 22-μm-wide electrodes, were used as a platform where the effect of localised, high-strength electric fields could be tested. Alternating current, square-wave pulses were applied to the IDEs in 1 sec intervals. A two-level, three-variable factorial design experiment was used to detect the effects of applied voltage, frequency, and pulse duty ratio (i.e. percentage of pulsing time over one cycle) on the inhibition of biofilm formation. The observations indicated that a pulse configuration of 1% duty ratio, 5 V, and 200 Hz frequency reduced the area of the electrodes covered by biofilm by 50%. In general, the application of low-duty ratio pulses had a positive effect on preventing biofouling. Comparatively, frequency and applied voltage were observed to have less influence on biofouling.  相似文献   

12.
A luteolytic dose (500 micrograms) of cloprostenol was given on Day 12 of the oestrous cycle to 5 heifers. Blood samples were collected simultaneously from the caudal vena cava and jugular vein at 5-20-min intervals from -6 to 0 (control period), 0 to 12 and 24 to 36 h after PG injection. Pulses of LH were secreted concomitantly with pulses of FSH during all sampling periods. However, during the control period separate FSH pulses were detected resulting in a shorter (P less than 0.01) interpulse interval for FSH than LH (93 versus 248 min). LH and FSH pulse frequencies increased (P less than 0.01) beginning 1-3 h after PG to interpulse intervals of 59 and 63 min, respectively, and continued to be maintained 24-36 h after PG. Concomitantly there was a 2-3-fold increase (P less than 0.01) in basal concentrations and pulse amplitude for LH (but not FSH). FSH basal concentrations and pulse amplitudes decreased (P less than 0.05) in 3 heifers 24-36 h after PG. Pulsatile secretion of oestradiol was observed at frequencies similar to LH during the periods 4-12 h (3 heifers) and 24-36 h (2 heifers) after PG, respectively, resulting in higher (P less than 0.05) mean oestradiol concentrations. Progesterone concentrations in the vena cava increased (P less than 0.01) 5-10 min after PG but decreased (P less than 0.01) 67% by 20 min after PG. This decrease was followed by a rise (P less than 0.05) beginning 2-3 h after PG and lasting for an average of 3.3 h.(ABSTRACT TRUNCATED AT 400 WORDS)  相似文献   

13.
Pulsatile insulin secretion has been reported from a variety of in vivo and in vitro systems. While it is agreed that insulin pulses exist, there is little agreement concerning the basal frequency or interpulse interval either within the same species in vivo, as both long and short term pulses have been reported, or between in vivo and in vitro preparations. We propose that the frequency of sampling may have profound effects upon the calculated pulse interval. Three systems were used to test this hypothesis: 1) artificial test data were designed to produce regular pulses with an exact 11 min period, 2) perfusate insulin concentration from isolated canine pancreata sampled at 1 min intervals and 3) peripheral blood insulin concentrations from human volunteers sampled every 2 and 5 min. Pulse parameters were determined at 1, 2, 5, 20, 15, 30 and 60 min sampling intervals for each data set by the use of the computer algorithms Pulsar and Cycle Detector. The results indicate that for insulin secretory pulses, sampling frequencies longer than 2 min may result in the production of spurious pulse trains with multiple longer term pulse periods. It is concluded that islet hormone secretory pulse period calculations are dependent upon the sampling frequency.  相似文献   

14.
皮氏菊头蝠回声定位声波与年龄的关系   总被引:2,自引:0,他引:2  
皮氏菊头蝠 (Rhinolophuspearsoni)雌性成体 5只和幼体 2只采自贵州省贞丰县珉谷镇。采用超声波探测仪 (D980 ,ULTRASOUNDDETECTOR)接收皮氏菊头蝠的回声定位声波 ,转换到原频率的 1 / 1 0后导入计算机 ,然后用专业声谱分析软件 (Batsound 3 1 0 )进行分析。成蝠在飞行和悬挂状态下的声波结构相似 ,只是声波各项参数值略有不同 :它们发射FM CF FM型声波 ,具有 2~ 3个谐波 ,主频率在飞行时为 5 6 80± 0 6 2kHz ,悬挂时为 5 8 0 5± 0 2 4kHz ;声脉冲时间和间隔在飞行时分别为 3 4 6 2± 5 2 9ms和 86 5 0± 1 9 72ms ,悬挂时分别为 4 1 0 8± 5 87ms和 1 1 7 2 9± 6 6 4 4ms ;能率环飞行时为 ( 4 4 0 6± 1 2 5 8) % ,悬挂时为 ( 4 6 0 0±2 4 2 5 ) %。幼蝠声波为CF FM型 ,谐波数为 5~ 8个 ,主频率明显低于成体 ,FM带宽窄于成体 ,声脉冲时间和间隔短于成体 ,能率环低于成体。皮氏菊头蝠回声定位声波与年龄有关 ,这可能因成体的声波主要是探测食物和周围环境的详细信息 ,而幼体主要是与母蝠进行交流。  相似文献   

15.
The present study aimed to investigate the possible effect of pulse-modulated radiofrequency radiation (RFR) on rat skin hydroxyproline content, since skin is the first target of external electromagnetic fields. Skin hydroxyproline content was measured using liquid chromatography mass spectrometer method. Two months old male wistar rats were exposed to a 900 MHz pulse-modulated RFR at an average whole body specific absorption rate (SAR) of 1.35 W/kg for 20 min/day for 3 weeks. The radiofrequency (RF) signals were pulse modulated by rectangular pulses with a repetition frequency of 217 Hz and a duty cycle of 1:8 (pulse width 0.576 ms). A skin biopsy was taken at the upper part of the abdominal costa after the exposure. The data indicated that whole body exposure to a pulse-modulated RF radiation that is similar to that emitted by the global system for mobile communications (GSM) mobile phones caused a statistically significant increase in the skin hydroxyproline level (p = 0.049, Mann–Whitney U test). Under our experimental conditions, at a SAR less than the International Commission on Non-Ionizing Radiation Protection safety limit recommendation, there was evidence that GSM signals could alter hydroxyproline concentration in the rat skin.  相似文献   

16.
Dependence of the microwave effect on modulation parameters (pulse width, duty ratio, and peak intensity) was studied in an isolated frog auricle preparation. The rate and amplitude of spontaneous auricle twitches were measured during and after a 2 min exposure to 915 or 885 MHz microwaves and were compared to preexposure values. The studied ranges of modulation parameters were: pulse width, 10?6–10?2 s; duty ratio, 7:100000, and peak specific absorption rate, 100-3000 W/kg. Combinations of the parameters were chosen by chance, and about 400 various exposure regimes were tested. The experiments established that no regime was effective unless the average microwave power was high enough to induce preparation heating (0.1–0.4°C). The twitch rate instantly increased, and the amplitude decreased, as the temperature rose; similar changes could be induced by equivalent conventional heating. The data provide evidence that the effect of short-term microwave exposure on the isolated heart pacemaker and contractile functions depends on pulse modulation just as much as modulation determines the average absorbed power. These functions demonstrated no specific dependence on exposure parameters such as frequency or power windows. © 1995 Wiley-Liss, Inc.  相似文献   

17.
Temporal analyses were applied to the tone pulses within the courtship songs of Drosophila melanogaster, D. simulans,their interspecific hybrid, and behavioral mutants of D. melanogaster.Linear regression was performed on various parameters of the song pulses (cycles per pulse, absolute peak amplitude, intrapulse frequency, number of peaks in fast Fourier transform, width of the primary frequency peak, and interpulse interval), as a function of their positions within pulse trains. Significant differences in the slope values of these two species and of the mutant genotypes allowed for discriminative quantification of temporal changes within trains. These results are discussed in relation to previous kinds of temporal analyses of Drosophilacourtship songs and also with regard to the mechanisms of song production.  相似文献   

18.
Taddei-ferretti  Cloe  Musio  Carlo  Santillo  Silvia  Cotugno  Antonio 《Hydrobiologia》2004,530(1-3):129-134
Hydra’s response to a light pulse is a phase shift of the state of bioelectric activity correlated with the periodic shortening-elongation behaviour. The direction and absolute value of a phase shift depend on intensity, direction, application phase (along the periodic activity state), and wavelength of the light pulse. Repetitive pulses entrain the behavioural cycle. The period of the behavioural cycle depends on intensity and wavelength of steady background illumination; however, the light effect is not exerted isotropically along all the phases of the behavioural cycle. Inferences are drawn on light influence on the behaviour pacemaking mechanism. By using polyclonal antibodies against squid rhodopsin, an opsin-like protein has been identified in the ectodermal layer, presumably in sensory cells.  相似文献   

19.
In the present study, we first investigated the effects of various types of low-energy, low-frequency electromagnetic fields (EMFs) on DNA synthesis in UMR-106 osteoblast-like cells. The experimental groups were exposed to EMFs for 2 days (twice/day, 30 min/time), and DNA synthesis was measured. The results showed that the cells responded most sensitively to EMFs of some specific combinations of the parameters by an increase in DNA synthesis, implying that EMFs with a specific waveform rather than a complex one can be used in clinical electrotherapy. The parameters were as follows: pulsed electric field (PEF) with pulse width 0.2 ms, field strength 10 V/cm, frequency 125 Hz; sinusoidal electric field (SEF) with field strength 1 V/cm, frequency 10 Hz; and alternating magnetic field (AMF) with field density 0.5 mT, frequency 5 Hz. In addition to frequency, the field strength or field density within a suitable intensity scale played a dominant role in causing the DNA synthesis response. We then compared the effects of two kinds of fields, PEF and AMF, with the optimum parameters identified by the experiments, on alkaline phosphatase (ALP) activity, protein and collagen synthesis, and intracellular levels of cyclic adenosine monophosphate (cAMP). The results indicated that both fields could not only affect UMR-106 cells proliferation but could particularly affect a series of characteristic bioactivities of UMR-106 such as ALP activity and collagen synthesis. The intracellular cAMP levels were increased rapidly and greatly with exposure to both PEF and AMF, implying that the action of low-frequency EMFs proceeds via second messenger-dependent processes originating from signals at the cell membrane. The difference in action between PEF and AMF suggests that they may couple to the cell membrane in a partially different way.  相似文献   

20.
Effects of contraction frequency and duty cycle on diaphragmatic blood flow   总被引:1,自引:0,他引:1  
The effects of diaphragmatic contraction frequency (no. of intermittent tetanic contractions/min) at a given tension-time index and of duty cycle (contraction time/total cycle time) on diaphragmatic blood flow were measured in anesthetized mongrel dogs during bilateral supramaximal phrenic nerve stimulation. Diaphragmatic blood flow was measured by the radionuclide-labeled microsphere method. Contraction frequency was varied between 10 and 160/min at duty cycles of 0.25 and 0.75. Diaphragmatic blood flow increased with contraction frequency from 1.47 +/- 0.13 ml X min-1 X g-1 (mean +/- SE) at an average of 18/min to 2.65 +/- 0.16 ml X min-1 X g-1 at 74/min (P less than 0.01) with a duty cycle of 0.25 and from 1.32 +/- 0.19 ml X min-1 X g-1 at an average of 15/min to 1.96 +/- 0.15 ml X min-1 X g-1 at 80/min (P less than 0.02) with a duty cycle of 0.75. At higher contraction frequencies diaphragmatic blood flow did not increase further at both duty cycles. In addition, diaphragmatic blood flow was higher with a duty cycle of 0.25 than 0.75 at all contraction frequencies. We conclude that frequency of contraction is a major determinant of diaphragmatic blood flow and that high duty cycle impedes diaphragmatic blood flow.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号