首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method for the determination of dihydroetorphine hydrochloride, a powerful anaesthetic and analgesic drug, in biological fluids by GC-MS with selected-ion monitoring using etorphine as internal standard was established. Dihydroetorphine was extracted from human blood and urine with dichloromethane and then derivatized with N-heptafluorobutyrylimidazole after concentration to dryness. A dihydroetorphine monoheptafluorobutyl derivative was formed which showed good behavior on GC-MS with electronic-impact ionization. The main fragment, m/z 522, which is the base peak, was selected as the ion for quantitation and the corresponding ion, m/z 520, was selected for monitoring the internal standard, etorphine. The recoveries and coefficients of variation of the whole procedure were determined with five controlled dihydroetorphine-free urine and plasma samples spiked with different concentrations of dihydroetorphine. The concentration of dihydroetorphine for quantitation was in the range 1–20 ng/ml for urine and 2.5–250 ng/ml for plasma. The correlation coefficients of the standard curves are sufficient to determine the dihydroetorphine. The accuracy for quantitation of dihydroetorphine in urine and plasma is less than 10.6%.  相似文献   

2.
Three high-performance liquid chromatographic methods are described for the detection of the novel antifolate anticancer drug (6R)-5,10-dideaza-5,6,7,8-tetrahydrofolate (lometrexol): one with fluorometric detection and two with detection by UV absorbance. An assay for plasma lometrexol using UV detection (288 nm) and reversed-phase chromatography was developed, with a quantitation limit of 0.2 μg/ml and linearity up to 10 μg/ml. This assay was modified for measurement of lometrexol in urine, with a quantitation limit of 2 μg/ml and linearity up to 25 μg/ml. An alternative assay for plasma lometrexol using derivatization and fluorescence detection (excitation at 325 nm, emission at 450 nm) was also developed, which proved twenty-fold more sensitive (quantitation limit of 10 ng/ml) than the UV assay, and which was linear up to 250 ng/ml. The fluoremetric method requires sample oxidation with manganese dioxide prior to analysis, and uses ion-pair chromatography with tetramethylammonium hydrogensulphate as an ion-pair reagent. All assays use a similar preliminary solid-phase extraction method (recovery as assessed by UV absorption >73%), with C10-desmethylene lometrexol added for internal standardisation. Each assay is highly reproducible (inter-assay precision in each assay is <10%). Applicability of the fluorescence-based assay to lometrexol in plasma and the UV-based assay lometrexol in urine is demonstrated by pharmacokinetic studies in patients treated as part of a Phase I clinical evaluation of the drug.  相似文献   

3.
This paper presents specific and sensitive high-performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS) assays for the quantification of the novel anticancer agent eribulin in human plasma, whole blood, urine and faeces. These assays, developed to support clinical pharmacological studies with the drug, quantify eribulin concentration ranges of 0.2-100ng/mL for plasma, 0.5-100 ng/mL for whole blood and urine and 0.1-25 μg/g for faeces, using sample volumes of 500 μL or 250 μg (faeces). Samples were prepared with liquid-liquid extraction, separated on a C18 column with gradient elution and analysed with a triple quadrupole MS, in positive ion mode. A structural analogue of eribulin was used as internal standard for the quantification. The assays were linear with correlation coefficients (r(2)) of 0.99 and better, whereby the deviation from nominal concentrations ranged from -8.2 to 8.9% with CV values of maximally 14.2%. Stability assessments demonstrated that eribulin is stable at -20°C in plasma, whole blood, urine and faeces for at least 38, 4, 10.5 and 5 months, respectively. In conclusion, the validation results show that the assays are specific and accurate and can therefore adequately be applied to support clinical studies of eribulin.  相似文献   

4.
The following paper represents a simple, highly sensitive, responsive validated and developed spectrofluorimetric method for estimation of imatinib (IMB) in its pure, commercial preparation, human urine and human blood plasma. The calibration curve was in the range 4–900 ng ml?1 for pure form and urine and 8–900 ng ml?1 for plasma in a medium contains carboxymethyl cellulose (CMC) and acetate buffer (pH 5) with excitation wavelength (λex) 230 nm and emission wavelength (λem) 307 nm. The limit of detection (LOD) was 0.37 ng ml?1 for the pure form, 0.64 ng ml?1 for human urine, and 0.70 ng ml?1 for human plasma, while the limit of quantitation (LOQ) was 1.2 for pure form, 1.91 for urine and 2.1 for plasma. The suggested method was successfully applied for evaluation of IMB in tablets within 99% mean percentage recovery. The excipients that are usually used as additives in pharmaceutical dosage form did not interfere with the suggested method. The method was efficiently used for estimation of IMB in human urine and human plasma. The effect of some cations that might be present in urine and plasma was also studied. The method was also focused on human volunteers and in vitro drug release.  相似文献   

5.
Alentamol hydrobromide, (+)-2-(dipropylamino)-2,3-dihydro-1H-phenalen-5-ol monohydrobromide, is a selective dopamine agonist currently being investigated for the treatment of schizophrenia. This paper describes a reversed-phase high-performance liquid chromatographic-based method for the quantification of alentamol in blood plasma and urine. The method utilizes solid-phase extraction with carboxylic acid-derivatized silica columns. A limit of quantitation of 0.1 ng/ml in plasma was achieved by virtue of selective extraction and fluorescence detection. Example chromatograms of plasma and urine specimens from clinical trials demonstrate the utility of the method.  相似文献   

6.
A rapid, sensitive and selective high-performance liquid chromatographic (HPLC) assay was developed for the determination of cibenzoline (Cipralan TM) in human plasma and urine. The assay involves the extraction of the compound into benzene from plasma or urine buffered to pH 11 and HPLC analysis of the residue dissolved in acetonitrile---phosphate buffer (0.015 mol/1, pH 6.0) (80:20). A 10-μ ion-exchange (sulfonate) column was used with acetonitrile—phosphate buffer (0.015 mol/1, pH 6.0) (80:20) as the mobile phase. UV detection at 214 nm was used for quantitation with the di-p-methyl analogue of cibenzoline as the internal standard.The recovery of cibenzoline in the assay ranged from 60 to 70% and was validated in human plasma and urine in the concentration range of 10–1000 ng/ml and 50–5000 ng/ml, respectively. A normal-phase HPLC assay was developed for the determination of the imidazole metabolite of cibenzoline. The assays were applied to the determination of plasma and urine concentrations of cibenzoline and trace amounts of its imidazole metabolite following oral administration of cibenzoline succinate to two human subjects.  相似文献   

7.
A simple and sensitive method for quantitation of HSR-609 (I) in human plasma and urine was developed using HPLC with the fluorescence labelling reagent 4-(N,N-dimethylaminosulfonyl)-7-N-piperazino-2,1,3-benzoxadiazole (DBD-PZ). Compound I was extracted from human plasma and urine, and derivatized by reaction with DBD-PZ in the presence of Mukaiyama reagent A, an equimolar solution of 2,2′-dipyridyl disulfide (DPDS) and triphenylphosphine (TPP) in acetonitrile. The reaction mixture was cleaned up by liquid-liquid extraction following the derivatization. The conjugate was analyzed by ion-pair HPLC with fluorometric detection. The quantitation limits for I were 0.5 ng/ml in plasma and 5 ng/ml in urine. Using this method, plasma concentration and urinary excretion of I were studied after oral administration of I to human volunteers.  相似文献   

8.
An analytical method for the determination of letrozole (CGS 20 267) in plasma and of letrozole and its metabolite, CGP 44 645, in urine is described. Automated liquid-solid extraction of compounds from plasma and urine was performed on disposable 100-mg C8 columns using the ASPEC system. The separation was achieved on an ODS Hypersil C18 column using acetonitrile-phosphate buffer, pH 7, as the mobile phase at a flow-rate of 1.5 ml/min. A fluorescence detector was used for the quantitation. The excitation and emission wavelengths were 230 and 295 nm, respectively. The limits of quantitation (LOQ) of letrozole in plasma and in urine were 1.40 nmol/l (0.4 ng/ml) and 2.80 nmol/l, respectively. The respective mean recoveries and coefficient of variation (C.V.) were 96.5% (9.8%) in plasma and 104% (7.7%) in urine. The LOQ of CGP 44 645 in urine was 8.54 nmol/l (2 ng/ml). The mean recovery was 108% (6.3%). The compounds were well separated from co-extracted endogenous components and no interferences were observed at the retention times of compounds. The sensitivity of this method for letrozole in plasma should be sufficient for kinetic studies in humans with single doses of 0.5 mg and possibly less.  相似文献   

9.
A sensitive and efficient liquid chromatography-mass spectrometry method was developed and validated for the simultaneous determination of two active chromones (prim-O-glucosylcimifugin and 4'-O-D-glucosyl-5-O-methylvisamminol) from Saposhnikovia root in rat plasma and urine. The plasma or urine samples were prepared by protein precipitation. Chromatographic separation of the two active chromones from matrix interferences was achieved on an Angilent TC-C(18) column with a mobile phase consisted of methanol, water and 0.1% formic acid. Puerarin was added as the internal standard. The method was validated with the concentration range 1.0-100 ng/mL in rat plasma and 10-1000 ng/mL in urine for prim-O-glucosylcimifugin, 1.5-150 ng/mL in plasma and 15-1500 ng/mL in urine for 4'-O-D-glucosyl-5-O-methylvisamminol. The lower limit of quantitation (LLOQ) of prim-O-glucosylcimifugin and 4'-O-D-glucosyl-5-O-methylvisamminol was 1.0 and 1.5 ng/mL in plasma, 10 and 15 ng/mL in urine, respectively. The intra- and inter-day precision across three validation days over the entire concentration range was lower than 9.0% as terms of relative standard deviation (R.S.D.). Accuracy determined at three quality control concentrations (2.0, 25 and 75 ng/mL for prim-O-glucosylcimifugin; 3.0, 37.5 and 112.5 ng/mL for 4'-O-D-glucosyl-5-O-methylvisamminol) ranged from -1.9 to 3.9% as terms of relative error (R.E.). The LC-ESI-MS method was further applied to assess pharmacokinetics and urine excretion of the two chromones after oral administration of Fangfeng extract to rats. Practical utility of this new LC-MS method was confirmed in pilot pharmacokinetic studies in rats following oral administration.  相似文献   

10.
Doxepin is a tricyclic antidepressant marketed as an irrational mixture of cis- and trans-geometric isomers in the ratio of 15:85. A convenient high-performance liquid chromatographic (HPLC) procedure for simultaneous quantitation of geometric isomers of doxepin and N-desmethyldoxepin in plasma and urine is described. The HPLC procedure employed a normal phase system with a silica column and a mobile phase consisting of hexane-methanol-nonylamine (95:5:0.3, v/v/v), a UV detector and nortriptyline as the internal standard. The liquid-liquid extraction solvent was a mixture of n-pentane-isopropanol (95:5, v/v). The limit of quantitation was 1 ng/ml for each isomer. The calibration curves were linear over the ranges 1–200 ng/ml (plasma) and 1–400 ng/ml (urine). In plasma, the accuracy (mean±S.D.) (97.53±1.67%) and precision (3.89±1.65%) data for trans-doxepin were similar to corresponding values for urine, i.e., 97.10±2.40 and 3.82±1.14%. Accuracy and precision data for trans-N-desmethyldoxepin in plasma were 97.57±2.06 and 4.38±3.24%, and in urine were 97.64±3.32 and 5.26±1.83%, respectively. Stability tests under three different conditions of storage indicated no evidence of degradation. The recovery of doxepin was 61–64% from plasma and 63–68% from urine. The method has been applied to analyses of plasma and urine samples from human volunteers and animals dosed with doxepin.  相似文献   

11.
Sensitive and specific HPLC assays for APCP363 in biological matrices (rat plasma, urine and feces) were developed. The recovery of APCP363 ranged from 81.2 to 99.9% in plasma, from 82.1 to 92.8% in urine, and from 65 to 68% in feces. Standard deviations were below 10% for all analyses. The limits of quantitation were 0.1, 10 and 30 μg/ml in plasma, urine and feces, respectively. The HPLC assays, which are the first reports for APCP363 analysis in biological matrices, have been successfully applied to preliminary pharmacokinetic studies in rats. The stool assay is the first non-radiolabeled method for hydroxypyridinones in feces.  相似文献   

12.
Biomarker discovery produces lists of candidate markers whose presence and level must be subsequently verified in serum or plasma. Verification represents a paradigm shift from unbiased discovery approaches to targeted, hypothesis-driven methods and relies upon specific, quantitative assays optimized for the selective detection of target proteins. Many protein biomarkers of clinical currency are present at or below the nanogram/milliliter range in plasma and have been inaccessible to date by MS-based methods. Using multiple reaction monitoring coupled with stable isotope dilution mass spectrometry, we describe here the development of quantitative, multiplexed assays for six proteins in plasma that achieve limits of quantitation in the 1-10 ng/ml range with percent coefficients of variation from 3 to 15% without immunoaffinity enrichment of either proteins or peptides. Sample processing methods with sufficient throughput, recovery, and reproducibility to enable robust detection and quantitation of candidate biomarker proteins were developed and optimized by addition of exogenous proteins to immunoaffinity depleted plasma from a healthy donor. Quantitative multiple reaction monitoring assays were designed and optimized for signature peptides derived from the test proteins. Based upon calibration curves using known concentrations of spiked protein in plasma, we determined that each target protein had at least one signature peptide with a limit of quantitation in the 1-10 ng/ml range and linearity typically over 2 orders of magnitude in the measurement range of interest. Limits of detection were frequently in the high picogram/milliliter range. These levels of assay performance represent up to a 1000-fold improvement compared with direct analysis of proteins in plasma by MS and were achieved by simple, robust sample processing involving abundant protein depletion and minimal fractionation by strong cation exchange chromatography at the peptide level prior to LC-multiple reaction monitoring/MS. The methods presented here provide a solid basis for developing quantitative MS-based assays of low level proteins in blood.  相似文献   

13.
A sensitive reversed-phase high-performance liquid chromatographic fluorescence method is described for the simultaneous determination of topotecan (I) and the hydrolysed lactone ring-opened product hydroxy acid (II) in plasma and for the determination of I in urine. To 250 μl of plasma, a 750-μl volume of cold methanol was added to stabilize the pH-dependent conversion of I into II. In plasma, the lower limit of quantitation (LLQ) for both compounds was 0.10 ng/ml. The between-day variation for I at the LLQ was 7.1% and for II was 5.5%. Prior to injection, urine samples were acidified with orthophosphoric acid and diluted with phosphate-buffered saline (PBS). In urine, the calibration curve for I was linear in the range of 10 to 250 ng/ml and the LLQ was 10 ng/ml. The assay was developed to enable pharmacological analysis of I, in on-going phase I and II studies, in patients with solid tumors.  相似文献   

14.
Methods for the measurement of penicillin concentration in bovine plasma, kidney and urine were developed and validated. Detection was based on liquid chromatography/tandem mass spectrometry (LC/MS/MS). Phenethecillin was used as an internal standard. Plasma was extracted with acetonitrile using a method with a calculated limit of quantitation (LOQ) of 12 ng/mL. Kidney samples were homogenized in water and acetonitrile, then cleaned up on C18-bonded silica SPE cartridges. The LOQ of this procedure was 10 ng/g. Urine samples were diluted, filtered, and analyzed directly. The LOQ of this procedure was 63 ng/mL. The overall accuracy for plasma was 103% with coefficient of variation (CV) of 3%; for kidney, 96% and 11%, respectively, and for urine, 98% and 4%, respectively. These methods were applied to the analysis of plasma, urine, and kidney biopsy samples taken from standing animals that had been dosed with penicillin.  相似文献   

15.
We have developed and validated a sensitive and selective assay for the quantification of paclitaxel and its metabolites 6α,3′-p-dihydroxypaclitaxel, 3′-p-hydroxypaclitaxel and 6α-hydroxypaclitaxel in plasma, tissue, urine and faeces specimens of mice. Tissue and faeces were homogenized (approximately 0.1–0.2 g/ml) in bovine serum albumin (40 g/I) in water, and urine was diluted (1:5, v/v) in blank human plasma. Sample pretreatment involved liquid-liquid extraction of 200–1000 μl of sample with diethyl ether followed by automated solid-phase extraction using cyano Bond Elut column. 2′-Methylpaclitaxel was used as internal standard. The overall recovery of the sample pretreatment procedure ranged from 76 ot 85%. In plasma, the lower limit of detection (LOD) and the lower limit of quantitation (LLQ) are 15 and 25 ng/ml, respectively, using 200 μl of sample. In tissues, faeces and urine the LLQs are 25–100 ng/g, 125 ng/g and 25 ng/ml, respectively, using 1000 μl (faeces: 200 μl) of homogenized or diluted sample. The concentrations in the various biological matrices, for validation procedures spiked with known amounts of the test compounds, are read from calibration curves constructed in blank human plasma in the range 25–100 000 ng/ml for paclitaxel and 25–500 ng/ml for the metabolites. The accuracy and precision of the assay fall within the generally accepted criteria for bio-analytical assays.  相似文献   

16.
A high-performance liquid chromatographic assay method for the quantitation of ipecac alkaloids (cephaeline and emetine) in human plasma and urine is described. Human plasma or urine was extracted with diethylether under alkaline conditions following the addition of an internal standard. Concentrations of alkaloids and internal standard were determined by octadecylsilica chromatographic separation (Symmetry C18 columns, plasma analysis; 15 cm×4.6 mm I.D., 5 μm particle size, urine analysis; 7.5 cm×4.6 mm I.D., 5 μm particle size). The mobile phase consisted of buffer (20 mmol/l 1-heptanesulfonic acid sodium salt, adjusted to pH 4.0 with acetic acid)–methanol (51:49, v/v). Eluate fluorescence was monitored at 285/316 nm. The lowest quantitation limits of cephaeline and emetine were 1 and 2.5 ng/ml, respectively, in plasma, and 5 ng/ml in urine. Intra- and inter-day relative standard deviations were below 15%. The assay is sensitive, specific and applicable to pharmacokinetic studies in humans.  相似文献   

17.
A method was developed for the rapid quantitative analysis of chlorpheniramine in plasma, saliva and urine using high-performance liquid chromatography. A diethyl ether or hexane extract of the alkalinized biological samples was extracted with dilute acid which was chromatographed on a reversed-phase column using mixtures of acetonitrile and ammonium phosphate buffer as the mobile phase. Ultraviolet absorption at 254 nm was monitored for the detection and brompheniramine was employed as the internal standard for the quantitation. The effects of buffer, pH, and acetonitrile concentration in the mobile phase on the chromatographic separation were investigated. A mobile phase 20% acetonitrile in 0.0075 M phosphate buffer at a flow-rate of 2 ml/min was used for the assays of plasma and saliva samples. A similar mobile phase was used for urine samples. The drug and internal standard were eluted at retention volumes of less than 17 ml. The method can also be used to quantify two metabolites, didesmethyl- and desmethylchlorpheniramine, in the urine. The method can accurately measure chlorpheniramine levels down to 2 ng/ml in plasma or saliva using 1 ml of sample, and should be adequate for biopharmaceutical and pharmacokinetic studies. Various precautions for using the assay are discussed.  相似文献   

18.
An isocratic online-enrichment HPLC-assay was developed allowing for the simple and fast separation and quantitation of STI-571 and its main metabolite N-desmethyl-STI (N-DesM-STI) in plasma, urine, cerebrospinal fluid (CSF), culture media and cell preparations in various concentrations using UV-detection at 260 nm. The analytical procedure consists of an online concentration of STI-571 and N-DesM-STI in the HPLC system followed by the elution on a ZirChrom-PBD analytical column. Time of analysis is 40 min including the enrichment time of 5 min. The detection limit is 10 ng/ml in plasma, CSF, culture medium (RPMI) and 25 ng/ml in urine for both STI-571 and N-DesM-STI. The intra-day precision, as expressed by the coefficient of variation (CV), in plasma samples ranges between 1.74 and 8.60% for STI-571 and 1.45 and 8.87% for N-DesM-STI. The corresponding values for urine measurements are 2.17-7.54% (STI-571) and 1.31-9.51% (N-DesM-STI). The inter-day precision analyzed over a 7-month time period was 8.31% (STI-571) or 6.88% (N-DesM-STI) and 16.45% (STI-571) or 14.83% (N-DesM-STI) for a concentration of 1000 ng/ml in plasma and 750 ng/ml in urine, respectively. Moreover, we demonstrate that with an alternative, but more time and labor consuming sample preparation and the implementation of electrochemical detection, a detection limit < 10 ng/ml can be achieved. The method described was used to perform pharmacokinetic measurements of STI-571 and N-desmethyl-STI in patient samples and for kinetic measurements of intracellular STI-571 and N-DesM-STI following in vitro incubation.  相似文献   

19.
A selective, accurate, precise and reproducible high-performance liquid chromatographic assay was developed for the quantitation of irbesartan, an angiotensin II antagonist, in human plasma and urine samples. The method involved solid-phase extraction of irbesartan and internal standard (I.S.) using a 100-mg Isolute CN cartridge. A portion of the eluate was injected onto an ODS analytical column connected to a fluorescence detector that was set at an excitation wavelength of 250 nm and an emission wavelength of 371 nm. The mobile phase consisted of 50% acetonitrile and a 50% weak phosphate-triethylamine solution, pH 3.5, at a flow-rate of 0.8 ml/min. The assay was linear from 1 to 1000 ng/ml with both plasma and urine. In either matrix, the lower limit of quantitation was 1 ng/ml. The analyses of quality control samples indicated that the nominal values could be predicted with an accuracy >95%. The inter- and intra-day coefficients of variation for the analyses in both matrices were <8%. Irbesartan was stable in both human plasma and urine for at least seven months at −20°C. The application of the assay to a pharmacokinetic study is described.  相似文献   

20.
Two new stable isotope dilution assays were developed for the quantification of ochratoxin A in human blood samples for exposure studies. The methods based on two different sample extraction and cleanup procedures including liquid–liquid extraction with following immunoaffinity chromatography (IA) as well as a dispersive solid-phase extraction (DSPE) method. For detection, LC–MS/MS was applied. For the first time, exact quantitation of the reference compound ochratoxin A was performed by quantitative NMR spectroscopy (qNMR). Additionally, a comparison of different blood-drawing procedures revealed no differences for heparin plasma and serum whereas citrate plasma gave significantly lower results for the mycotoxin. Limits of detection (LOD: 0.02 ng/g (IA) vs 0.03 ng/g (DSPE)), limits of quantification (LOQ: 0.07 ng/g (IA) vs 0.08 ng/g (DSPE)), relative recovery (?94%), precision, and linearity indicated excellent performance of the developed methods.  相似文献   