首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
A rapid, sensitive, and specific reversed-phase high-performance liquid chromatography assay was developed for the determination of 1,3,4-triphenylpyrazole-5-acetic acid (isofezolac) in plasma and urine. The assay involves extraction into diethyl ether from plasma buffered at pH 4.4. The organic phase is evaporated and the residue, dissolved in the mobile phase [acetonitrile—water—0.2 M phosphate buffer (pH 3) (65 : 15 : 20)] is chromatographed at a flow-rate of 1.5 ml/min. The drug is detected by its UV absorption (detection limit 100 ng/ml) or its very intense fluorescence (detection limit 10 ng/ml). Absolute analytical recoveries for isofezolac varied from 92.9 to 100.4%. The accuracy is ca. 1%. Each separation requires about 6 min. This method was applied successfully to the determination of isofezolac in humans for pharmacokinetic studies.  相似文献   

3.
A high-performance liquid chromatographic method for the analysis of sulpiride, N-ethyl-2-(2-methoxy-5-sulphonamido-benzamido-methyl)-pyrrolidine, in body fluids is described. A structurally related compound, N-ethyl-2-(2,4-dimethoxy-benzamido-methyl)-pyrrolidine, was used as internal standard.A fluorescence detector with excitation maximum at 299 nm and emission maximum at 342 nm was used for the quantitation. The detection limit was about 10 ng/ml in serum and cerebrospinal fluid and about 200 ng/ml in urine. The experimental error was 5–10% in the concentration range 25–100 ng/ml. Some preliminary data from a pharmacokinetic study in healthy volunteers are presented. The half-life for sulpiride in serum was about 8 h. Sulpiride was also measured in cerebrospinal fluid from five drug-treated psychotic patients.  相似文献   

4.
5.
A method for the rapid and sensitive fluorometric analysis of porphyrin carboxylic acids by reverse-phase high-performance liquid chromatography is described. Separation of free porphyrin carboxylic acids was carried out with a microparticulate octadecylsilane column with elution by a gradient of methanol in phosphate buffer containing tetrabutylammonium hydroxide. Separation and quantitation of di-, tri-, tetra-, penta-, hexa-, hepta-, and octacar-boxylic porphyrins was achieved within 25 min at picomolar concentrations. The method is also capable of separating the type I and type III isomers of tetracarboxylic through hexacarboxylic porphyrins. By using a stopped flow technique, one can record fluorescence excitation and emission spectra of porphyrin carboxylic acids. This method is directly applicable to biological fluids such as urine, plasma, red cell lysates, or medium or extracts from cell culture.  相似文献   

6.
7.
The rapid separation and quantitative determination of per-O-benzoyl oligosaccharides were obtained using high performance, liquid chromatography. Oligosaccharides were completely O-benzoylated without concomitant N-benzoylation of acetamidodeoxyhexoses. Benzoylation prior to analysis allowed a quantitative determination of picomolar amounts because the absorbance at 230 nm of these derivatives is directly proportional to the number of benzoyl groups present. Separation by normal and reversed-phase chromatography was demonstrated, and the best resolution was obtained on an Ultrasphere octyl column. Excellent separations of oligosaccharides containing up to 10 sugar residues present in mannosidosis urine and of malto-oligosaccharides containing up to 15 sugar residues present in Karo syrup were achieved within an analysis time of 30 min. Anomers of maltose, maltotriose, and maltotetraose were separated; for this reason, reduction of complex samples prior to analysis is advisable. The effect of linkage configuration on retention time was tested with reduced, α-linked di- and tri-glucopyranosides. The presence of an acetamidodeoxyhexose residue in an oligosaccharide significantly reduced its retention time, whereas branching had the opposite effect. A linear response was obtained for the injection of 1–600 pmol of raffinose, and the detection limit was 0.5 pmol. Derivatization and analysis of raffinose was shown to yield reproducible results within the range 0.01–1 μmol, and, with special precautions to minimize losses, as little as 100 pmol could be analyzed successfully.  相似文献   

8.
9.
10.
11.
12.
13.
Using 1-ml plasma samples, levels of 6-mercaptopurine (6MP) as low as 5 ng/ml and azathioprine (AZA) as low as 40 ng/ml can be detected using a high-performance liquid chromatography reversed-phase column procedure following extraction. Both compounds were stable in frozen plasma for seven weeks. AZA stability in blood was temperature dependent; the half-lives of AZA breakdown to 6MP at 37° were 28 and 46 min in blood drawn from two rhesus monkeys. Plasma levels of 6MP were measured in a rhesus monkey following 6MP (1.47 mg/kg) and AZA (3 mg/kg) intravenous administration. 6MP levels were also measured in three renal transplant patients on daily 50- and 100-mg AZA doses. Peak levels (45–75 ng/ml) were reached within an hour and 6MP levels were detected for up to 7 h.  相似文献   

14.
15.
A high-performance liquid chromatography system has been developed which resolves O-phosphoserine, O-phosphothreonine, and O4-phosphotyrosine. Separation is performed on an anion-exchange resin eluted with phosphate buffer of low pH. Detection of the amino acid derivatives is accomplished using O-phthalaldehyde in an in-stream fluorometric system. This highly sensitive method has been applied to the detection of phosphohydroxyamino acids in bovine myelin basic protein phosphorylated by the catalytic subunit of cyclic AMP-dependent protein kinase and in whole bovine myelin phosphorylated by endogenous kinases.  相似文献   

16.
A rapid and sensitive method was devised for determining β-galactosidase activity specific for galactocerebroside. A fluorescent derivative of galactocerebroside, 1-O-galactosyl-2-N-1-dimethylaminonaphthalene-5-sulfonyl-sphingosine, was used as substrate, and the product, 2-N-1-dimethylaminonaphthalene-5-sulfonyl-sphingosine, was taken into organic solvent phase. Quantitative analysis of 2-N-dimethylaminonaphthalene-5-sulfonyl-sphingosine was carried out fluorometrically by use of high-performance liquid chromatography on silica gel column.  相似文献   

17.
A rapid procedure for the isolation, separation, identification and measurement of urinary pyrimidine bases and nucleosides by high-performance liquid chromatography (HPLC) is presented. The initial isolation of these compounds from urine was accomplished with small disposable ion-exchange columns. HPLC was performed on a silica gel column with a mobile phase composed of methylene chloride, methanol and 1 M aqueous ammonium formate buffer. Peaks were recorded at both 254 nm and 280 nm and the response ratio was used in conjunction with the elution volume for compound identification. The minimum detectable amount (signal-to-noise ratio = 2) ranged from 0.2 ng for uracil to 2.2 ng for cytidine. Linearity and recovery for thymine, uracil, uridine, pseudouridine, orotic acid and orotidine added to urine was demonstrated over almost a 103 concentration range. The potential application of this method for the study of inborn errors in the urea cycle is discussed.  相似文献   

18.
19.
A method is described for the determination of cortisol in human plasma and urine by high-performance liquid chromatography using fluorophotometric detection. After extraction with methylene chloride, cortisol is labelled with dansyl hydrazine, and then separated by high-performance chromatography. The eluate is monitored by a fluorophotometer at 350 nm (excitation) and 505 nm (emission). The optimum conditions for the determination, such as HCl and dansyl hydrazine concentrations, reaction time and reaction temperature, and for the eluent of high-performance liquid chromatography, are discussed. Linearity of the fluorescence intensity (peak height) with the amount of cortisol was obtained between 0.5 and 60 ng. The recoveries for 50 and 100 ng of added cortisol were 98.7 and 95.4% for plasma, and 96.4 and 90.6% for urine, respectively. Comparison with a radioimmunoassay gave a correlation coefficient of 0.978. The proposed method is suitable for the routine analysis of cortisol in plasma and urine.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号