首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 218 毫秒
1.
A method is described for the qualiitative and quantitative determination of phenylbutazone and oxyphenbutazone in horse urine and plasma samples viewing antidoping control. A horse was administered intravenously with 3 g of phenylbutazone. For the qualitative determination, a screening by HPLC was performed after acidic extraction of the urine samples and the confirmation process was realized by GC-MS. Using the proposed method it was possible to detect phenylbutazone and oxyphenbutazone in urine for up to 48 and 120 h, respectively. For the quantitation of these drugs the plasma was deproteinized with acetonitrile and 20 gml were injected directly into the HPLC system equipped with a UV detector and LiChrospher RP-18 column. The mobile phase used was 0.01 M acetic acid in methanol (45:55, v/v). The limit of detection was 0.5 μg/ml for phenylbutazone and oxyphenbutazone and the limit of quantitation was 1.0 μg/ml for both drugs. Using the proposed method it was possible to quantify phenylbutazone up to 30 h and oxyphenbutazone up to 39 h after administration.  相似文献   

2.
A reliable reversed-phase high-performance liquid chromatographic method was developed for the determination of liposomal nystatin in plasma. Nystatin is extracted by 1:2 (v/v) liquid–liquid extraction with methanol. Separation is achieved by HPLC after direct injection on a μBondapak™ C18 analytical column with a mobile phase composed of 10 mM sodium phosphate, 1 mM EDTA, 30% methanol and 30% acetonitrile adjusted to pH 6. Detection is by ultraviolet absorbance at 305 nm. Quantitation is based on the sum of the peak area concentration of the two major isomers of nystatin, which elute at 7.5–8.5 and 9.5–10.5 min. The assay was linear over the concentration range of 0.05 to 50 μg/ml. The lower limit of quantitation was 0.05 μg/ml, sufficient for investigating the plasma pharmacokinetics of liposomal nystatin in preclinical studies. Accuracies and intra- and inter-day precision showed good reproducibility. With minor modifications, this method also was used for assaying nystatin in various non-plasma body fluids and tissues.  相似文献   

3.
A method is described for the simultaneous determination of l,α-acetylmethadol (LAAM) and five active metabolites — noracetylmethadol, dinoracetylmethadol, methadol, normethadol, and dinormethadol — in biofluids by high-performance liquid chromatography using a normal-phase column and a UV detector at 218 nm. The compounds are recovered from biofluids by a multistep liquid—liquid extraction. The mobile phase is methanol—acetonitrile (70:30, v/v) containing 0.015% ammonium hydroxide as the modifier. Retention times can be varied by adjusting the composition of the mobile phase to maximize peak height for quantitation using l-propranolol as the internal standard or peak separation for the collection of fractions. Using a UV detector the lower limit of sensitivity is 10 ng/ml of biofluid. Using fraction collection of radiolabeled drug and metabolites followed by liquid scintillation counting the lower limit of sensitivity is 1.0 ng/ml. Commonly used or abused narcotics including morphine, heroin, meperidine, methadone and propoxyphene do not interfere with the analysis. The method has been applied to plasma and urine samples from humans, sheep and rats. Extracts of urine from patients receiving maintenance treatment with LAAM contain LAAM and each of the five active metabolites.  相似文献   

4.
Ebastine (CAS 90729-43-4) is an antiallergic agent which selectively and potently blocks histamine H1-receptors in vivo. A simple and sensitive high-performance liquid chromatography (HPLC) method is described for the simultaneous determination of ebastine and its two oxidized metabolites, carebastine (CAS 90729-42-3) and hydroxyebastine (M–OH), in human plasma. After a pretreatment of plasma sample by solid-phase extraction, ebastine and its metabolites were analyzed on an HPLC system with ultraviolet detection at 254 nm. Chromatography was performed on a cyano column (250×4.0 mm I.D.) at 40 °C with the mobile phase of acetonitrile–methanol–0.012 M ammonium acetate buffer (20:30:48, v/v/v) at a flow rate of 1.2 ml/min. Accurate determinations were possible over the concentration range of 3–1000 ng/ml for the three compounds using 1 ml plasma samples. The intra- and inter-day assay accuracy of this method were within 100±15% of nominal values and the precision did not exceed 12.4% of relative standard deviation. The lower limits of quantitation were 3 ng/ml for ebastine and its metabolites in human plasma. This method was satisfactorily applied to the determination of ebastine and its two oxidized metabolites in human plasma after oral administration of ebastine.  相似文献   

5.
A high-performance liquid chromatographic method for quantitation of ibuprofen from serum and application of this method to ibuprofen disposition in the dog is described. The drug was extracted from acidified plasma with dichloromethane. The internal standard used was a methanolic solution of 4-n-butylphenylacetic acid. A μBondapak C1 column was used for analysis; the mobile phase was methanol—water—glacial acetic acid (pH 3.4) (75:24:1, v/v). A wavelength of 272 nm was used to monitor ibuprofen and the internal standard.Method sensitivity was 0.5 μg/ml serum using either 0.5 or 1.0 ml of sample, and no interference was found from endogenous compounds or other commonly used anti-inflammatory agents. The coefficients of variation of the method were 4.2% and 6.0% for samples containing 50.0 and 6.25 μg/ml of ibuprofen, respectively, and the calibration curve was linear for the range of 0.5 to 100 μg/ml. This method was demonstrated to be suitable for pharmacokinetic and/or biopharmaceutical studies of ibuprofen in man and the dog.  相似文献   

6.
A simple, specific and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of rifabutin in human plasma. Rifabutin and sulindac (internal standard) are extracted from human plasma using a C8 Bond Elut extraction column. Methanol (1 ml) is used to elute the compounds. The methanol is dried down under nitrogen and reconstituted in 250 μl of mobile phase. Separation is achieved by HPLC on a Zorbax Rx C8 column with a mobile phase composed of 0.05 M potassium dihydrogen phosphate and 0.05 M sodium acetate at pH 4.0-acetonitrile (53:47, v/v). Detection is by ultraviolet absorbance at 275 nm. The retention times of rifabutin and internal standard were approximately 10.8 and 6.9 min, respectively. The assay is linear over the concentration range of 5–600 ng/ml. The quantitation limit was 5 ng/ml. Both intra-day and inter-day accuracy and precision data showed good reproducibility.  相似文献   

7.
An improved, more efficient method for the determination of metoprolol and its two metabolites in human urine is reported. The simultaneous analysis of the zwitterionic metoprolol acidic metabolite (III, H117/04) with the basic metabolites α-hydroxymetoprolol (II, H119/66), metoprolol (I) and guanoxan (IV, internal standard) was achieved employing solid-phase extraction and isocratic reversed-phase HPLC. The analytes were extracted from urine (100 μl) using C18 solid-phase extraction cartridges (100 mg), and eluted with aqueous acetic acid (0.1%, v/v)–methanol mixture (40:60, v/v, 1.2 ml). The eluents were concentrated (250 μl) under vacuum, and aliquots (100 μl) were analysed by HPLC with fluorescence detection at 229 nm (excitation) and 309 nm (emission) using simple isocratic reversed-phase HPLC (Novapak C18 radial compression cartridge, 4 μm, 100×5 mm I.D.). Acetonitrile–methanol–TEA/phosphate buffer pH 3.0 (9:1:90, v/v) was employed as the eluent (1.4 ml/min). All components were fully resolved within 18 min, and the calibration curves for the individual analytes were linear (r2≥0.996) within the concentration range of 0.25–40.0 mg/ml. Recoveries for all four analytes were greater than 76% (n=4). The assay method was validated with intra-day and inter-day variations less than 2.5%.  相似文献   

8.
A high-performance liquid chromatographic method has been developed for the determination of pipotiazine in human plasma and urine. After selective extraction, pipotiazine and the internal standard (7-methoxypipotiazine) are chromatographed on a column packed with Spherosil XOA 600 (5 μm) using a 7:3 (v/v) mixture of diisopropyl ether—isooctane (1:1, v/v) + 0.2% triethylamine and diisopropyl ether—methanol (1:1, v/v) + 0.2% triethylamine + 2.6% water. The eluted compounds are measured by fluorescence detection. The sensitivity of the method was established at 0.25 ng/ml pipotiazine in plasma and 2 ng/ml pipotiazine in urine (C.V. < 5%). The method has been successfully applied to a pharmacokinetic study following a single oral administration of 10 mg of pipotiazine.  相似文献   

9.
A liquid chromatographic procedure using UV detection was coupled with ultrafiltration for the quantitation of free phenylbutazone in bovine plasma, in the range of 20 ng/ml to 2.0 μg/ml. Whole plasma samples (0.5 to 1 ml) were placed in a 2-ml centrifugal concentrator with a molecular-mass cut-off membrane of 10 000 and centrifuged at 4500 g for 2 h at 4°C using a fixed angle rotor. The ultrafiltrate was transferred to an LC vial with a 200-μl insert and 100 μl was injected into an LC system. The chromatographic system used a C18 reversed-phase column connected to a UV detector set at 264 nm. The mobile phase was 0.2 M sodium phosphate buffer (pH 7)–methanol (1:1). Recoveries of phenylbutazone from protein-free plasma water fortified at levels of 20 ng/ml to 2 μg/ml ranged from 91 to 93%, with relative standard deviations (R.S.D.s) ranging from 1 to 4%. The concentration of incurred non-protein bound phenylbutazone obtained from a cow intravenously dosed twice with 2 g phenylbutazone, 8 h apart, was 111, 26 and 11 ng/ml for 2, 72 and 104 h post first phenylbutazone dose, respectively.  相似文献   

10.
6-Thioguanine (6TG) and its metabolites were analyzed in human plasma with a reversed-phase high-performance liquid chromatographic method. 6TG and related compounds were extracted from plasma with an equal volume of 2 N perchloric acid at a 50–100% recovery efficiency. The neutralized extracts were chromatographed on a μBondapak C18 column by two separate isocratic conditions. 6TG, 6-thiouric acid, 6-thioxanthine, 6-thioguanosine, and 6-methylthiouric acid were analyzed with 0.01 M sodium acetate, pH 3.5–10% methanol as the mobile phase and 340 nm for detection. 6-Methylthioguanine and three unknown metabolites were separated with acetate—25% methanol and 310 nm detection. One of the unknowns was identified as 6-methylthioguanosine. External standard calibration was used for quantitation. The 6TG detection limit was 0.8 nmol/ml in plasma.  相似文献   

11.
A method is reported for the measurement of quercetin in human plasma using reversed-phase high-performance liquid chromatography (HPLC). Quercetin and kaempferol (as internal standard) were spiked into plasma samples and extracted using C18 Sep-Pak Light cartridges (efficiency > 85%). Flavonoids were eluted with aqueous acetone (50% v/v, pH 3.5), dried down and redissolved in aqueous acetone (45% v/v, pH 3.5). The increased osmolarity promoted a phase separation and the water-saturated acetone layer, containing the flavonoids, was analysed by HPLC with aqueous acetone mobile phase (45% v/v acetone in 250 mM sodium dihydrogen sulphate. The mixture was adjusted to pH 3.5 with phosphoric acid and used at a flow-rate of 1.0 ml/min) and μBondapak C18 column (150 × 3.9 mm I.D., 10 μm particle size). The detection limit (A375 nm) for quercetin in plasma was 0.1 μg/ml (300 nM). The method also detects metabolites of quercetin, although these are not yet identified.  相似文献   

12.
The purpose of this study was to investigate the possible presence of phenylbutazone in plasma samples from fighting bulls killed in 2nd and 3rd category bullrings in the province of Salamanca (Spain) in 1998, 1999 and 2000. For quantitative and qualitative determination, a high-performance liquid chromatograph was used, equipped with a photodiode-array detector and setting wavelengths at 240, 254 and 284 nm. The mobile phase optimized for the simultaneous detection of dexamethasone, betamethasone, flunixin and phenylbutazone, was 0.01 M acetic acid pH 3 in methanol (35:65 v/v) at a flow rate of 1 ml/min. Plasma samples were deproteinized with 400 microl of acetonitrile and 20 microl of the supernatant were injected directly into the chromatographic system equipped with a Lichrospher 60 RP select B column and guard column. For the quantitative analysis, standard calibration curves were made in a concentration range between 0.25 and 30 microg/ml, using betamethasone as internal standard. The retention time of phenylbutazone was 8.7 +/- 0.2 min and recovery was 83%. The detection and quantification limits were 0.016 and 0.029, respectively for A=240 nm. The study results show that 17 of the 74 samples analyzed in 1998, 18 of those from 1999 and 10 of those from 2000 were positive for phenylbutazone.  相似文献   

13.
A simple, rapid and reproducible high-performance liquid chromatographic assay for cisapride and norcisapride in human plasma is described. Samples of plasma (150 μl) were extracted using a C18 solid-phase cartridge. Regenerated tubes were eluted with 1.0 ml of methanol, dried, redissolved in 150 μl of methanol and injected. Chromatography was performed at room temperature by pumping acetonitrile–methanol–0.015 M phosphate buffer pH 2.2–2.3 (680:194:126, v/v/v) at 0.8 ml/min through a C18 reversed-phase column. Cisapride, norcisapride and internal standard were detected by absorbance at 276 nm and were eluted at 4.3, 5.3 and 8.1 min, respectively. Calibration plots in plasma were linear (r>0.998) from 10 to 150 ng/ml. Intraday precisions for cisapride and norcisapride were 3.3% and 5.4%, respectively. Interday precisions for cisapride and norcisapride were 9.6% and 9.0%, respectively. Drugs used which might be coadministered were tested for interference.  相似文献   

14.
A simple and rapid (extractionless) high-performance liquid chromatographic method with UV detection, at 330 nm, was developed for the simultaneous determination of piroxicam and its major metabolite, 5′-hydroxypiroxicam, in human plasma and urine. Acidified plasma and alkali-treated urine samples are used and naproxen is added as internal standard. The separation is performed at 40°C on a C18 Spherisorb column with acetonitrile-0.1 M sodium acetate (33:67, v/v, pH 3.3) as mobile phase. The retention time is 2.2 min for 5′-hydroxypiroxicam, 2.6 min for piroxicam and 3.2 min for naproxen. The detection limit is 0.05 μg/ml using a 100-μl loop.  相似文献   

15.
A fully automated gradient high-performance liquid chromatographic method for the determination of isotretinoin, tretinoin and their 4-oxo metabolites in plasma was developed, using the column-switching technique. After dilution with an internal standard solution containing 20% acetonitrile, 0.5 ml of the sample was injected onto a precolumn (17x4.6 mm I.D.), filled with C18 Corasil 37–53 μm. Proteins and polar plasma components were washed out using 1% ammonium acetate-acetonitrile (9:1, v/v) as mobile phase 1. After valve switching, the retained components were transferred to the analytical column in the backflush mode, separated by gradient elution and detected at 360 nm by UV detection. Using two coupled reversed-phase columns (125 mm long), the separation of cis and trans isomers was possible, and all four compounds could be quantified down to 2 ng/ml of plasma. The inter-assay precision in the concentration range 20-1000 ng/ml was between 1.0 and 4.7% for all compounds.  相似文献   

16.
Ebrotidine is a new H2-receptor antagonist with powerful antisecretory activity, demonstrated gastroprotection and the ability to inhibit protease and lipase activities of Helicobacter pylori. As a tool in the clinical pharmacokinetic study of ebrotidine, an analytical method for the simultaneous determination of ebrotidine an its metabolites in human urine was developed. An ion-pair reversed-phase HPLC separation using 1-hexanesulfonic acid and acetonitrile as mobile phase with gradient elution was optimized. In addition, several procedures of preconcentration and clean-up were tested, including solid-phase and liquid—liquid extraction, the mixture dichloromethane—2-propanol (9:1, v/v) at pH 11 being the most efficient. The quality parameters of the whole analytical method were established, the calibration curves were linear over the range studied (1–200 μg/ml) and the reproducibility of the method was high (inter-day R.S.D. values lower than 4.4%).The limits of detection were between 26 and 110 ng/ml of urine for ebrotidine and its metabolites. The method was applied to the analysis of urine collected from two volunteers during 96 h following oral administration of ebrotidine at a dose of 400 mg.  相似文献   

17.
A high-performance liquid chromatographic method for the measurement of bumetamide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol—water—glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5–2000 ng/ml.  相似文献   

18.
A simple method based on high-performance liquid column chromatography with electrochemical detection is described for the simultaneous determination of dopamine, 3,4-dihydroxyphenylacetic acid (DOPAC) and homovanillic acid (HVA) in discrete brain regions of rats. The supernatant of a tissue homogenate is injected directly onto a liquid chromatograph, thus omitting the commonly adopted adsorption step. Of the four different supports tested Nucleosil C19 (5 μm) was found superior with respect to chromatographic performance. The effects of pH, methanol and the ion-pairing agent hexyl sulfate on the retention were studied. The mobile phase used in the final studies consisted of citrate buffer pH 4.25—methanol (92:8, v/v) containing hexyl sulfate (1.7 · 10?3M). Standard curves of dopamine, DOPAC and HVA were found linear up to about 600 pmol per injection for each compound. The precisions of the chromatographic step were (srel. %): 0.72% (dopamine), 1.26% (DOPAC) and 2.69% (HVA).  相似文献   

19.
A single-solvent extraction step high-performance liquid chromatographic method is described for quantitating midazolam and its two hydroxy metabolites in rat serum microsamples (50 μl). The separation used a 2 mm I.D. reversed-phase Symmetry C18 column with an isocratic mobile phase consisting of methanol-acetonitrile-14.9 mM sodium acetate in water at pH 3.0 (10:23:67, v/v). The detection limit was 10 ng/ml for all the compounds using an ultraviolet detector operated at 230 nm. The method was used to study the pharmacokinetics of midazolam after an intravenous bolus dose (0.75 mg/kg).  相似文献   

20.
A high-performance liquid chromatographic method with ultraviolet photometric detection for the determination of cotinine in human plasma was described. The use of a 30-cm reversed-phase column and of a mobile phase consisting of water—methanol—0.1 M sodium acetate—acetonitrile (72:21:5.6:1.4, v/v), pH 4.1, eliminated caffeine interference. A simplified solid-phase extraction procedure was also performed for plasma samples.  相似文献   