首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new analytical approach utilizing a biofilm reactor (BFR) for rapid online determination of biochemical oxygen demand (BOD) was proposed and experimentally validated. The BFR was fabricated via a cultivation process using naturally occurring microbial seeds from locally collected wastewaters. The resultant BFR displays a remarkable rate of biodegradation towards a wide spectrum of organic substrates, capable of degrading over 20% of biodegradable organic substrates within 100 s. More importantly, the BFR exhibits a superior indiscriminative biodegradation feature, enabling a precise prediction of BOD values of total biodegradable organics based on experimentally determined BOD values from partial degradation processes without a need for on-going calibration. The proposed approach was systematically validated using a range of individual organic substrates, their mixtures, synthetic samples and wastewaters. Highly significant linear correlations between the BFR and the standard BOD(5) methods were obtained from diversified synthetic samples (r=0.988, p=0.000, n=45) and wastewaters (r=0.983, p=0.000, n=40). Near unity slope values of the principal axis of the correlation ellipse were obtained from all tested samples, suggesting both methods were essentially measuring the same BOD value. The reported method could be a useful online monitoring tool for determination of biodegradable organic pollutants.  相似文献   

2.
Summary A simple expression has been derived to demonstrate that the ratio of COD to BOD is not constant but a function of the thermodynamic efficiency of the growth process. An analysis of data reported in literature indicates that this ratio can assume a wide range of values for different substrates. The influence of a selected change in the environmental conditions, on the ratio, COD/BOD, has been evaluated experimentally, in a bacterial system.  相似文献   

3.
The biochemical oxygen demand (BOD) value is still a key parameter that can determine the level of organics, particularly the content of biodegradable organics in water. In this work, the effects of sample dilution, which should be done inevitably to get appropriate dissolved oxygen (DO) depletion, on the measurement of 5-day BOD (BOD5), was investigated with and without seeding using natural and synthetic water. The dilution effects were also evaluated for water samples taken in different seasons such as summer and winter because water temperature can cause a change in the types of microbial species, thus leading to different oxygen depletion profiles during BOD testing. The predation phenomenon between microbial cells was found to be dependent on the inorganic nutrients and carbon sources, showing a change in cell populations according to cell size after 5-day incubation. The dilution of water samples for BOD determination was linked to changes in the environment for microbial growth such as nutrition. The predation phenomenon between microbial cells was more important with less dilution. BOD5 increased with the specific amount of inorganic nutrient per microbial mass when the natural water was diluted. When seeding was done for synthetic water samples, the seed volume also affected BOD due to the rate of organic uptake by microbes. BOD5 increased with the specific bacterial population per organic source supplied at the beginning of BOD measurement. For more accurate BOD measurements, specific guidelines on dilution should be established.  相似文献   

4.
Liu C  Ma C  Yu D  Jia J  Liu L  Zhang B  Dong S 《Biosensors & bioelectronics》2011,26(5):2074-2079
To improve the practicability of rapid biochemical oxygen demand (BOD) method, we proposed a stable BOD sensor based on immobilizing multi-species BODseed for wastewater monitoring in the flow system. The activation time of the biofilm was greatly shortened for the biofilm prepared by BODseed in the organic-inorganic hybrid material. Some influence factors such as temperature, pH, and concentration of phosphate buffer solution (PBS) were investigated in detail in which high tolerance to environment was validated for the BOD sensor permitted a wide pH and PBS concentration ranges. The minimum detectable BOD was around 0.5 mg/l BOD under the optimized 1.0 mg/ml BODseed immobilized concentration. The as-prepared BOD sensor exhibited excellent stability and reproducibility for different samples. Furthermore, the as-prepared BOD biosensor displayed a notable advantage in indiscriminate biodegradation to different organic compounds and their mixture, similar to the character of conventional BOD(5) results. The results of the BOD sensor method are well agreed with those obtained from conventional BOD(5) method for wastewater samples. The proposed rapid BOD sensor method should be promising in practical application of wastewater monitoring.  相似文献   

5.
This study evaluates the kinetic parameters of biochemical reaction in three-phase fluidized bed biofilm reactor from the steady state values of the response of the system to step changes in inlet concentration. It was observed from the outlet biological oxygen demand (BOD(5)) plot of the response of the system that as the inlet BOD(5) was increased, the outlet BOD(5) also increased, reached a peak value and then decreased until it leveled to a new steady state value corresponding to the new inlet concentration level. The increase in BOD(5) was attributed to the accumulation of substrate within the reactor as well as the decrease in biofilm substrate consumption rate as the microorganisms adjusted to the new environment. Using the substrate balance at steady state and assuming Monod kinetics, an equation relating the substrate consumption rate to substrate concentration (BOD(5)) and total biofilm surface area had been established. Monod kinetic parameters were found to be K=2.20g/m(2)/day, K(m)=17.41g/m(3) and K/K(m)=0.13m/day. The ratio K/K(m) can be taken as the indicator for biofilm substrate degradation effectiveness at low substrate concentrations.  相似文献   

6.
A BOD monitoring system based on a bio-chip which immobilized luminous bacterium in micrometer-order holes were arrayed and fabricated by micro-machine techniques, was developed. The acrylic chip (3 cmx3 cm) comprises nine micro-holes (diameter: 700 microm or 1 mm, depth: 100 microm) arranged in a three by three array. Cells of the marine luminous bacterium, Photobacterium phosphoreum IFO 13896, which was grown at 15 degrees C for 15 h, were immobilized with 3% or 15% sodium alginate gel. BOD standard solutions or actual sample solution (approximately 10 microl) was fallen onto the cell-arrayed chip, and then the chip was incubated at 25 degrees C for 25 min. After incubation, bioluminescence from the each hole was gray-scaled and measured by a chemi-imager or newly developed onsite-type-monitoring system using a digital camera and a mobile-type personal computer. BOD values less than 16 ppm could detect by the chip, in particular, linear relationship at the concentrations between 0 and 16 ppm could be observed when luminous cells were immobilized with 3% sodium alginate gel. Steady bioluminescence was observed on the chip in the presence of BOD standard solution (GGA solution) which contained mineral elements. Furthermore, simultaneous detection of BOD values in various samples could be employed in the single chip. These results showed that the monitoring system with bio-chip could achieve high-through-put and onsite BOD detection. Our newly developed onsite-type BOD detection system which was used a digital camera and a (mobile) laptop computer was applied to measure and detect organic pollution due to biodegradable substances in wastewater treatment system. The same performance as the chemi-imager system was obtained for data of bioluminescence. The obtained BOD values showed a similar correlation with that of the conventional method for BOD determination (BOD5). These results suggested for successful achievement of high-though-put and onsite detection of BOD in practical.  相似文献   

7.
氮对藻类生长与污水净化的影响   总被引:12,自引:3,他引:9  
  相似文献   

8.
A laboratory-scale experiment presents data that reveal the temporal characteristics of solids, biochemical oxygen demand (BOD5) and volatile fatty acids (VFAs) in the aerated liquid swine manure for minimizing odor generation potential during 190-day storage. The performance of 15-day aeration of liquid manure with initial total solids (TS) content from 0.5% to 4.0% was examined at low-intensity aeration rates, i.e., +35 mV oxidation-reduction potential (ORP), 1.0 mg O2/l and 3.0 mg O2/l dissolved oxygen (DO). Odor generation potential was evaluated using VFAs. The aeration process contributed remarkably to the decomposition of TS, total volatile solids (TVS), BOD5 and VFAs. Moreover, the stabilization of manure due to aeration could last up to 190 days. The TS reduction on day 190 ranging from 6.3% to 32.7%, 20.2% to 39.1%, 19.0% to 41.0% were realized under the intensities of +35 mV ORP, 1.0 and 3.0 mg O2/l, respectively. At the same time, the reduction of BOD5 and VFAs reached around 7.8% to 69.5%, 17.2% to 79.9% and 21.9% to 91.1%; 0.4% to 91.0%, 60.4% to 95.0% and 70.4% to 94.1%. The liquid manure with low solids (e.g., TS of 0.5% and 1.0%) offered an advantageous condition for aeration treatment, particularly for biodegradation of BOD5 and VFAs. The odor generation potential could also be evaluated by the levels of solids and BOD5 in the manure. Increasing aeration intensity would significantly diminish the odor generation potential for given levels of solids and/or BOD5. Fifteen-day aeration with intensity of 1.0 mg O2/l may be recommended at farm level for both odor control and energy savings.  相似文献   

9.
A biochemical oxygen demand (BOD) sensor has been developed, which is based on an immobilized mixed culture of microorganisms combined with a dissolved oxygen (DO) optical fiber. The sensing film for BOD measurement consists of an organically-modified silicate (ORMOSIL) film embedded with tri(4,7-diphenyl-1,10-phenanthroline) ruthenium(II) perchlorate and three kinds of seawater microorganisms immobilized on a polyvinyl alcohol sol-gel matrix. The BOD measurements were carried out in the kinetic mode inside a light-proof cell and with constant temperature. Measurements were taken for 3 min followed by 10 min recovery time in 10 mg/L glucose/glutamate (GGA) BOD standard solution, and the range of determination was from 0.2 to 40 mg/L GGA. The effects of temperature, pH and sodium chloride concentration on the BOD sensing films were studied. BOD values estimated by this optical BOD sensing film correlate well with those determined by the conventional BOD5 method for seawater samples.  相似文献   

10.
The main objective of this study is to assess the achievability of stringent discharge criteria i.e. BOD(5)<15 mg/L, TSS<15 mg/L and NH(4)-N<1mg/L during the treatment of tomato processing wastewater with COD of 2800-15,500 mg/L, BOD(5) of 1750-7950 mg/L, TKN of 48-340 mg/L and NH(4)-N of 21-235 mg/L. Two treatment systems, a UASB-aerobic system and a UASB-anoxic-aerobic system were tested. Furthermore due to alkalinity deficiency, in the raw wastewater, the study explored varying UASB effluent recirculation flowrates to the UASB influent to reduce additional alkalinity requirements. The UASB-anoxic-aerobic system was effective in treating tomato canning wastewater at an overall HRT of 1.75 days while achieving 98.5% BOD(5), 95.6% COD, 84% TSS and 99.5% NH(4)-N removal producing effluent BOD(5), COD, TSS, NH(4)-N, TKN, NO(2)-N, NO(3)-N and PO(4)-P of 10, 70, 15, 0.5, 3, 0, 60 and 4 mg/L, respectively. The biogas yield was 0.43 m(3)/kg COD removed.  相似文献   

11.
Biochemical oxygen demand (BOD) is an international regulatory environmental index for monitoring organic pollutants in wastewater and the current legislated standard test for BOD monitoring requires 5 days to complete (BOD5 test). We are developing a rapid microbial technique, MICREDOX, for measuring BOD by eliminating oxygen and, instead, quantifying an equivalent biochemical co-substrate demand, the co-substrate being a redox mediator. Elevated concentrations of Proteus vulgaris, either as free cells or immobilised in Lentikat disks, were incubated with an excess of redox mediator (potassium hexacyanoferrate(III)) and organic substrate for 1h at 37 degrees C without oxygen. The addition of substrate increased the catabolic activity of the microorganisms and the accumulation of reduced mediator, which was subsequently re-oxidised at a working electrode generating a current quantifiable by a coulometric transducer. The recorded currents were converted to their BOD5 equivalent with the only assumption being a fixed conversion of substrate and known stoichiometry. Measurements are reported both for the BOD5 calibration standard solution (150 mg l(-1) glucose, 150 mg l(-1) glutamic acid) and for filtered effluent sampled from a wastewater treatment plant. The inclusion of a highly soluble mediator in place of oxygen facilitated a high ferricyanide concentration in the incubation, which in turn permitted increased concentrations of microorganisms to be used. This substantially reduced the incubation time, from 5 days to 1h, for the biological oxidation of substrates equivalent to those observed using the standard BOD5 test. Stoichiometric conversion efficiencies for the oxidation of the standard substrate by P. vulgaris were typically 60% for free cells and 35-50% for immobilised cells.  相似文献   

12.
A feasibility test of a 17 m3-pilot-scale sewage treatment system was carried out by continuous feeding of raw municipal sewage under ambient temperature conditions. The system consisted of a UASB and an aerated fixed bed reactor. Some of the effluent from the fixed bed reactor was returned to the UASB influent in order to provide a sulfate source. The total BOD of 148-162 mg l(-1) in the influent was reduced to a more desirable 11-25 mg l(-1) in the final effluent. The levels of methane-producing activity from acetate and H2/CO2 gas at 10 degrees C were only 2% and 0% of those at 35 degrees C, respectively. On the other hand, the sulfate-reducing activity levels of the UASB sludge were relatively high at 10 degrees C, for example, 18% for acetate and 9% for H2/CO2 gas, compared to the activity levels at 35 degrees C. Therefore, BOD oxidization by sulfate reduction in the UASB was greater than that by methane production under low temperature conditions. This sulfate-reducing activity tended to be proportional to the copy number of adenosine-5'-phosphosulfate (APS) reductase genes in DNA extracted from the sludge.  相似文献   

13.
生物传感器快速测定BOD的研究   总被引:13,自引:0,他引:13  
生化需氧量(biochemicaloxygendemand,BOD)是一种表征水体有机污染程度的综合指标,广泛应用于水体监测和废水处理厂的运行控制。由于BOD的标准测定方法需时5天,不能及时地反映水质状况和反馈处理信息,因此快速测定BOD的方法和仪器化研究近年来得到广泛的重视。利用生物传感器测定BOD是一种有效地快速测定废水中可生化降解有机物的方法。介绍生物传感器的工作原理及其生物敏感材料,讨论BOD传感器的性能参数以及BOD快速测定值(BODst)与标准BOD5值的一致性问题。对现阶段市场上常见的几种BOD快速测定仪进行简单的介绍,并对它们的性能进行比较 。  相似文献   

14.
AIMS: Evaluation of the efficiency of peracetic acid in the disinfection of wastewater in a large treatment plant. METHODS AND RESULTS: Over a period of 18 months 30 sample collections were made, each consisting of three samples taken from: raw incoming sewage, secondary effluent (after 10-12 h) and secondary effluent disinfected with 1.5-2 mg l(-1) of peracetic acid (contact time: 20 min). Total coliforms and Escherichia coli declined from 10(7) MPN 100 ml(-1) in the raw sewage to 10(2) in the disinfected effluent and the enterococci fell from 10(6) MPN 100 ml(-1) to 702 MPN 100 ml(-1). The reduction of bacteria increased with the rise in temperature and decreased with the rise in BOD5. CONCLUSIONS: Disinfection with peracetic acid reduced levels of faecal contamination by 97%, thus attaining the limit recommended by current Italian law (Escherichia coli 相似文献   

15.
The titres of physiological processes in bacteria (hydrolysis of urea, nitrification), total number of bacteria and photosynthesis were found to show high correlation with standard characteristics: BOD5 and saprobic index. The classificatory values of BOD5 and saprobic index depend on the pollution of waters (with BOD5 less than 3 mg O2/l more information on the extent of pollution is given by the saprobic index whereas with higher values BOD5 is better). The content of NH3-N and titres of ammonification and H2S production depend on the type of pollution and should not be used for determination of water purity without additional studies. Of increasing importance as a measure of pollution is the BOD5/BOD2 quotient.  相似文献   

16.
A microbial sensor for rapid measurement of the amount of biodegradable substances based on the salt-tolerant yeast Arxula adeninivorans LS3 has been developed especially for coastal and island regions. Our parameter, the so-called sensorBOD, that is available after only a few minutes, agrees with the 5-day value for the biochemical oxygen demand (BOD5) very well. We have employed the Arxula sensor in the short-time estimation and supervision of the BOD of both domestic and industrial wastewater with high salinity. The novel sensor makes it possible to monitor the different types of wastewater rapidly without pretreatment, and it can be used for an active process control of sewage treatment works. Compared to a commercially available sensor, the novel sensor achieves better agreement between sensorBOD and BOD5 measurements with salt containing samples.  相似文献   

17.
A novel BOD sensor based on bacterial luminescence   总被引:4,自引:0,他引:4  
A reagent-type BOD sensor with a new principle employing a luminous bacterium, Photobacterium phosphoreum, was developed. The increased intensity of luminescence resulting from the cellular assimilation of organic compounds in wastewater was detected by a photodiode. The BOD response of the bacterial reagent could be obtained within 15 min with +/-7% error. The temperature condition for optimal BOD response was 18 degrees to 25 degrees C at pH 7 to 8, indicating that it is possible to measure BOD at room temperature without having to stabilize the temperature of the measuring system. For practical use, two procedures for long-term preservation of the bacterial reagent, vacuum drying method and freezing method, are suggested. The metabolic characteristics of employed luminous bacteria were investigated by comparing the BOD values for several pure organic substrates estimated by the BOD sensor with conventional 5-day BOD values. In comparison with the 5-day measurement for some wastewater samples, BOD values estimated by the sensor showed comparatively good agreement with those measured by the 5-day method. (c) 1993 Wiley & Sons, Inc.  相似文献   

18.
A biochemical oxygen demand (BOD) sensing system based on bacterial luminescence from recombinant Escherichia coli containing lux A-E genes from Vibrio fischeri has been developed. It was possible to use frozen cells of luminescent recombinants of E. coli as the bacterial reagents for measurement. Steady bioluminescence was observed during the incubation time between 90 and 150 min in the presence of a sole carbon source such as glucose, acetate, L-glutamate and BOD standard solution (GGA solution). This disposable bacterial reagent was applied to measure and detect organic pollution due to biodegradable substances in various wastewaters. The obtained values of this study showed a similar correlation with that of the conventional method for BOD determination (BOD5). Bacterial luminescence that was visualized with an imaging system using a charge coupled device (CCD) camera and a photomulti-counter demonstrated that this method could also be used for multi-sample detection of organic pollution due to biodegradable substances by using a microtiter plate. These results suggested for successful achievement of high-though-put detection of BOD in practical.  相似文献   

19.
Biochemical oxygen demand (BOD) is a measure of the amount of dissolved oxygen that is required for the biochemical oxidation of the organic compounds in 5 days. New biosensor-based methods have been conducted for a faster determination of BOD. In this study, a mathematical model to evaluate the feasibility of using a BOD sensor, based on disposable alginate-entrapped bacteria, for monitoring BOD in situ was applied. The model considers the influences of alginate bead size and bacterial concentration. The disposable biosensor can be adapted according to specific requirements depending on the organic load contained in the wastewater. Using Klein and Washausen parameter in a Lineweaver–Burk plot, the glucose diffusivity was calculated in 6.4 × 10−10 (m2/s) for beads of 1 mm in diameter and slight diffusion restrictions were observed (n = 0.85). Experimental results showed a correlation (p < 0.05) between the respirometric peak and the standard BOD test. The biosensor response was representative of BOD.  相似文献   

20.
Current routine genotyping methods typically do not provide haplotype information, which is essential for many analyses of fine-scale molecular-genetics data. Haplotypes can be obtained, at considerable cost, experimentally or (partially) through genotyping of additional family members. Alternatively, a statistical method can be used to infer phase and to reconstruct haplotypes. We present a new statistical method, applicable to genotype data at linked loci from a population sample, that improves substantially on current algorithms; often, error rates are reduced by > 50%, relative to its nearest competitor. Furthermore, our algorithm performs well in absolute terms, suggesting that reconstructing haplotypes experimentally or by genotyping additional family members may be an inefficient use of resources.  相似文献   