首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
本文研究了由嗜肺军团杆菌的巨噬细胞感染性增效子(mip)基因设计的一对引物,用PCR扩增嗜肺军团杆菌3、5、7、8血清型的4个标准菌株的特异DNA序列,研究了用该引物扩增BAL液中嗜肺军团菌特异DNA序列的方法、灵敏度及特异性。结果表明:用上述引物扩增嗜肺军团菌4个标准菌株的DNA,均可得到207bp的特异扩增产物,BAL液中的军团菌经离心及裂解液裂解后,可直接进行DNA扩增,当BAL与液中军团菌量为2×103CFU/ml时,即可检测出特异扩增带(电泳法),除军团菌外,其它受试细菌均无此特异性扩增,用本法对42例临床非典型肺炎患者的BAL液进行嗜肺军团菌的检测,在42份嗜肺军团菌培养均为阴性的BAL液中,其中一例PCR检测军团菌为阳性。本研究提示:用PCR检测BAL液中的军团菌是可行的,并有快速、灵敏、特异之忧点。  相似文献   

2.
Isothermal nucleic acid sequence-based amplification (NASBA) was applied to detect Legionella 16S rRNA. The assay was originally developed as a Legionella pneumophila conventional NASBA assay with electrochemiluminescence (ECL) detection and was subsequently adapted to a L. pneumophila real-time NASBA format and a Legionella spp. real-time NASBA using molecular beacons. L. pneumophila RNA prepared from a plasmid construct was used to assess the analytical sensitivity of the assay. The sensitivity of the NASBA assay was 10 molecules of in vitro wild type L. pneumophila RNA and 0.1-1 colony-forming units (CFU) of L. pneumophila. In spiked respiratory specimens, the sensitivity of the NASBA assays was 1-10000 CFU of L. pneumophila serotype 1 depending on the background. After dilution of the nucleic acid extract prior to amplification, 1-10 CFU of L. pneumophila serotype 1 could be detected with both detection methods. Finally, 27 respiratory specimens, well characterized by culture and PCR, collected during a L. pneumophila outbreak, were tested by conventional and real-time NASBAs. All 11 PCR positive samples were positive by conventional NASBA, 9/11 and 10/11 were positive by L. pneumophila real-time NASBA and Legionella spp. real-time NASBA, respectively.  相似文献   

3.
A new real-time PCR assay was developed and validated in combination with an immunomagnetic separation system for the quantitative determination of Legionella pneumophila in water samples. Primers that amplify simultaneously an 80-bp fragment of the dotA gene from L. pneumophila and a recombinant fragment including a specific sequence of the gyrB gene from Aeromonas hydrophila, added as an internal positive control, were used. The specificity, limit of detection, limit of quantification, repetitivity, reproducibility, and accuracy of the method were calculated, and the values obtained confirmed the applicability of the method for the quantitative detection of L. pneumophila. Moreover, the efficiency of immunomagnetic separation in the recovery of L. pneumophila from different kinds of water was evaluated. The recovery rates decreased as the water contamination increased (ranging from 59.9% for distilled water to 36% for cooling tower water), and the reproducibility also decreased in parallel to water complexity. The feasibility of the method was evaluated by cell culture and real-time PCR analysis of 60 samples in parallel. All the samples found to be positive by cell culture were also positive by real-time PCR, while only eight samples were found to be positive only by PCR. Finally, the correlation of both methods showed that the number of cells calculated by PCR was 20-fold higher than the culture values. In conclusion, the real-time PCR method combined with immunomagnetic separation provides a sensitive, specific, and accurate method for the rapid quantification of L. pneumophila in water samples. However, the recovery efficiency of immunomagnetic separation should be considered in complex samples.  相似文献   

4.
Bivalve molluscs concentrate Cryptosporidium oocysts from fecal-contaminated aquatic environments and are therefore useful in monitoring water quality. A real-time TaqMan polymerase chain reaction (PCR) system was developed to allow for large scale quantitative detection of Cryptosporidium spp. in mussels (Mytilus californianus). The TaqMan sensitivity and specificity were compared to conventional PCR and direct immunofluorescent antibody (DFA) assays, with and without immunomagnetic separation (IMS), to identify the best method for parasite detection in mussel hemolymph, gill washings and digestive glands. TaqMan PCR and two conventional PCR systems all detected 1 or more oocysts spiked into 1 ml hemolymph samples. The minimum oocyst detection limit in spiked 5 ml gill wash and 1 g digestive gland samples tested by TaqMan PCR and DFA was 100 oocysts, with a 1 log(10) improvement when samples were first processed by IMS. For tank exposed mussels, TaqMan and conventional PCR methods detected C. parvum in <5% of hemolymph samples. No gill washings from these same mussels tested positive by TaqMan PCR or DFA analysis even with IMS concentration. All methods detected the highest prevalence of C. parvum-positive samples in digestive gland tissues of exposed mussels. In conclusion, the most sensitive method for the detection of C. parvum in oocyst-exposed mussels was IMS concentration with DFA detection: 80% of individual and 100% of pooled digestive gland samples tested positive. TaqMan PCR was comparable to conventional PCR for detection of C. parvum oocysts in mussels and additionally allowed for automated testing, high throughput, and semi-quantitative results.  相似文献   

5.
This study describes the development and evaluation of a specific Legionella pneumophila Taqman duplex real-time PCR (qPCR) for fast and reliable quantification of this human pathogen in suspected man-made water systems. The qPCR assay was 100% specific for all L. pneumophila serogroups 1-15 with a sensitivity of 60 genome units/l and an amplification efficiency of 98%. Amplification inhibitors were detected via an exogenous internal positive control, which was amplified simultaneously with L. pneumophila DNA using its own primer and probe set. Mean recovery rates of the qPCR assay for tap water and cooling circuit water, spiked with a known number L. pneumophila bacteria, were 93.0% and 56.3%, respectively. Additionally, by using the Ultraclean Soil DNA isolation kit, we were able to remove amplification inhibitors ubiquitously present in cooling water. The practical value of our qPCR assay was evaluated through analysis of 30 water samples from showers, taps, eyewash stations, fire sprinklers and recirculation loops with qPCR and traditional culture. In conclusion, the described L. pneumophila Taqman duplex real-time assay proved to be specific, sensitive and reproducible. This makes it a promising method complementing the current time-consuming culture standard method.  相似文献   

6.
Abstract Using direct fluorescent antibody (DFA) staining technique, Legionella pneumophila SG 1, 3 and 5 was evident in water samples collected from different localities of central Italian regions, Marche and Abruzzi; L. pneumophila SG 1 and 3 was also detected in aquatic stages of arthropods living in the Legionella -positive waters. Diptera, Coleoptera, Collembola and Isopoda were found to be positive for legionellas by DFA. Diptera, the most common in the waters surveyed, were represented by Chironomidae and Culicidae families, the latter being larval and pupal stages of genus Anopheles and Culex . Mosquito adults, emerged in laboratory from pupae collected in one sample of positive water, were also positive. The findings that aquatic arthropods harbor legionellas and whether they could be involved in the maintenance and dissemination of legionellas in nature are discussed.  相似文献   

7.
Legionella pneumophila is one of the most important pathogens which cause community-acquired pneumonia. Although TNF-alpha is considered to play an important role in response to bacteria, the role of the TNF-alpha receptor on L. pneumophila infection remains to be elucidated. To investigate this, we infected TNF receptor deficient mice with L. pneumophila. L. pneumophila was inoculated intranasally into TNF receptor (TNFR)-1-knock-out mice or TNFR2-knock-out mice. The mortality rate, histology of the lung, bacterial growth in the lung, and bronchoalveolar lavage (BAL) fluids were investigated. The bacterial growth of L. pneumophila in the macrophages was also studied. Almost all the mice survived after an intranasal inoculation of 1x10(6)CFU/head of L. pneumophila, but more than 90% mice were killed after inoculation of 1x10(8)CFU/head of L. pneumophila. In the case of TNFR1-knock-out mice and TNFR2-knock-out mice, a high mortality rate was observed after inoculation of 1x10(7)CFU/head of L. pneumophila in comparison to wild-type mice. The lung histology from both the TNFR1-knock-out mice documented severe lung injury at day 3 after inoculation. The clearance of L. pneumophila in the lung of the TNFR1-knock-out mice was slower than those from both the TNFR2-knock-out mice and the wild-type mice. Moreover, L. pneumophila growth in the peritoneal macrophages from the TNFR1-knock-out mice was observed. Interestingly, a lack of neutrophils accumulation in the BAL fluids and a dysregulation of cytokines (IFN-gamma, interleukin-12, and TNF-alpha) were observed in the TNFR1-knock-out mice. On the contrary, large accumulation of neutrophils in BAL fluids was observed in TNFR2-knock-out mice. These data suggested that a TNFR1 deficiency led to a compromise of the innate immunity against L. pneumophila, while a TNFR2 deficiency induced an excessive inflammatory response and resulted in death. The present study confirmed that TNFR1 and TNFR2 play a crucial, but different role in the control of L. pneumophila-induced mortality.  相似文献   

8.
A new real-time PCR assay was developed and validated in combination with an immunomagnetic separation system for the quantitative determination of Legionella pneumophila in water samples. Primers that amplify simultaneously an 80-bp fragment of the dotA gene from L. pneumophila and a recombinant fragment including a specific sequence of the gyrB gene from Aeromonas hydrophila, added as an internal positive control, were used. The specificity, limit of detection, limit of quantification, repetitivity, reproducibility, and accuracy of the method were calculated, and the values obtained confirmed the applicability of the method for the quantitative detection of L. pneumophila. Moreover, the efficiency of immunomagnetic separation in the recovery of L. pneumophila from different kinds of water was evaluated. The recovery rates decreased as the water contamination increased (ranging from 59.9% for distilled water to 36% for cooling tower water), and the reproducibility also decreased in parallel to water complexity. The feasibility of the method was evaluated by cell culture and real-time PCR analysis of 60 samples in parallel. All the samples found to be positive by cell culture were also positive by real-time PCR, while only eight samples were found to be positive only by PCR. Finally, the correlation of both methods showed that the number of cells calculated by PCR was 20-fold higher than the culture values. In conclusion, the real-time PCR method combined with immunomagnetic separation provides a sensitive, specific, and accurate method for the rapid quantification of L. pneumophila in water samples. However, the recovery efficiency of immunomagnetic separation should be considered in complex samples.  相似文献   

9.
For detection of Brucella species by PCR four DNA extraction methods and four targets were compared using pure culture of Brucella melitensis and the best conditions were applied in clinical samples. It was found that the MagNA Pure LC method was the most efficient and sensitive method showing a positive PCR reaction with DNA extracted from as low as 25 and 100 CFU suspended in one ml blood and one ml water, respectively. Detection of Brucella spp. by conventional PCR was investigated using four different targets. The results indicated that The B4-B5 amplification method was the most sensitive one as it could amplify DNA extracted from as a low as 25 and 100 CFU/ml suspended in one ml water and blood, respectively. Furthermore real-time PCR was able to detect Brucella using DNA extracted from as low as 50 CFU/ml blood and 15 CFU/ml water, respectively. The best and optimum detection conditions were applied to the clinical samples. Evaluation of conventional PCR assays on blood specimens confirmed 72% of the results obtained by conventional blood culture methods with a specificity of 95%, while serum samples had a sensitivity of 54% and specificity of 100%. Real-time PCR was generally found to be more sensitive and specific for detecting Brucella spp. in blood and serum samples compared to conventional PCR. The real-time PCR done on blood specimens confirmed 77.5% of the results obtained by conventional blood culture methods with specificity of 100%, while 60% of serum samples were found to be positive with specificity of 100%. These results suggest that serum and blood analysis by conventional and real time PCR is a convenient and safe method for rapid and accurate diagnosis of brucellosis.  相似文献   

10.
The presence of high levels of Legionella pneumophila in man-made aquatic systems correlates with the incidence of nosocomial Legionnaires' disease. This requires a rapid, reliable, and sensitive quantification of L. pneumophila concentrations in suspected water systems. In this research, a homologous competitor was developed and evaluated in a L. pneumophila competitive polymerase chain reaction (cPCR) to quantify this human pathogen in a quick, cost-effective, and reliable way. Accuracy of cPCR was evaluated by analyzing cooling tower and tap water samples spiked with known concentrations of L. pneumophila bacteria, in parallel with the standard culture method. Legionella pneumophila amounts detected and calculated from cPCR and culture correlated very well: r = 0.998, P = 0.002 for tap water and r = 0.990, P = 0.009 for cooling tower water. Nevertheless, for both kinds of water samples, mean numbers of L. pneumophila calculated from cPCR results were always higher than those obtained by culture. This study makes it clear that the rapid, sensitive, and cost-effective L. pneumophila cPCR is a promising alternative to the standard time-consuming culture method and expensive real-time PCR to enumerate L. pneumophila bacteria in environmental water samples.  相似文献   

11.
A new method for the rapid and sensitive detection of Legionella pneumophila in hot water systems has been developed. The method is based on an IF assay combined with detection by solid-phase cytometry. This method allowed the enumeration of L. pneumophila serogroup 1 and L. pneumophila serogroups 2 to 6, 8 to 10, and 12 to 15 in tap water samples within 3 to 4 h. The sensitivity of the method was between 10 and 100 bacteria per liter and was principally limited by the filtration capacity of membranes. The specificity of the antibody was evaluated against 15 non-Legionella strains, and no cross-reactivity was observed. When the method was applied to natural waters, direct counts of L. pneumophila were compared with the number of CFU obtained by the standard culture method. Direct counts were always higher than culturable counts, and the ratio between the two methods ranged from 1.4 to 325. Solid-phase cytometry offers a fast and sensitive alternative to the culture method for L. pneumophila screening in hot water systems.  相似文献   

12.
An automated method to detect salmonellae in foods was developed and tested in food samples intentionally contaminated with the test organisms. Liquid eggs, shell eggs, dry eggs, skim milk and chicken were spiked with Salmonella enteritidis, S. typhimurium or S. newport to yield 2 to 25 CFU per 25 g or ml of sample. Following pre-enrichment in universal pre-enrichment broth at 42 degrees C for 6 h (eggs and milk) or 16 h (chicken), Salmonella cells were captured by immunomagnetic beads coated with Salmonella antibody (Vicam, Watertown, MA). The beads were transferred to selective liquid media containing carbohydrate (dulcitol or xylose), amino acid (lysine or ornithine), and H2S indicator, and incubated at 42 degrees C in the BioSys instrument (MicroSys, Ann Arbor, MI). Salmonella positive samples were identified by black discoloration of the media during incubation, while negative samples remained colorless. These color changes were recorded by the instrument. All the artificially contaminated samples tested positive within 15-18 h, while control samples remained negative during 24 h incubation. The results agreed with standard identification procedures. A total of 24 h was required to detect 2 to 25 CFU of the pathogen in 25 g or ml of eggs and milk, and up to 36 h in chicken, compared to 72 h in the standard methods.  相似文献   

13.
In order to reduce the risks of Legionnaires' disease, caused by the bacterium Legionella pneumophila, disinfection of tap water systems contaminated with this bacterium is a necessity. This study investigates if electrochemical disinfection is able to eliminate such contamination. Hereto, water spiked with bacteria (10(4)CFU Escherichia coli or L. pneumophila/ml) was passed through an electrolysis cell (direct effect) or bacteria were added to tap water after passage through such disinfection unit (residual effect). The spiked tap water was completely disinfected, during passage through the electrolysis cell, even when only a residual free oxidant concentration of 0.07 mg/l is left (L. pneumophila). The residual effect leads to a complete eradication of cultivable E. coli, if after reaction time at least a free oxidant concentration of 0.08 mg/l is still present. Similar conditions reduce substantially L. pneumophila, but a complete killing is not realised.  相似文献   

14.
Both 25-g single-size ground beef samples and 375-g composite ground beef samples were tested by a method combining an immunomagnetic separation (IMS) technique with a sandwich enzyme-linked immunosorbent assay (ELISA) system (IMS-ELISA). The results demonstrated that IMS-ELISA could detect the target, Escherichia coli O157:H7, at the level of 10(-1) CFU/g of sample in either the 25- or 375-g sample size.  相似文献   

15.
AIMS: An evaluation was made of the prevalence of Legionella species in hot water distribution systems in the city of Bologna (Italy) and their possible association with bacterial contamination (total counts and Pseudomonadaceae) and the chemical characteristics of the water (pH, Ca, Mg, Fe, Mn, Cu, Zn and Total Organic Carbon, TOC). METHODS AND RESULTS: A total of 137 hot water samples were analysed: 59 from the same number of private apartments, 46 from 11 hotels and 32 from five hospitals, all using the same water supply. Legionella species were detected in 40.0% of the distribution systems, L. pneumophila in 33.3%. The highest colonization was found in the hot water systems of hospitals (93.7% of samples positive for L. pneumophila, geometric mean: 2.4 x 10(3) CFU l(-1)), followed by the hotels (60.9%, geometric mean: 127.3 CFU l(-1)) and the apartments with centralized heating (41.9%, geometric mean: 30.5 CFU l(-1)). The apartments with independent heating systems showed a lower level of colonization (3.6% for Legionella species), with no evidence of L. pneumophila. Correlation analysis suggests that copper exerts an inhibiting action, while the TOC tends to favour the development of L. pneumophila. No statistically significant association was seen with Pseudomonadaceae, which were found at lower water temperatures than legionellae and in individual distribution points rather than in the whole network. CONCLUSIONS: The water recirculation system used by centralized boilers enhances the spreading of legionellae throughout the whole network, both in terms of the number of colonized sites and in terms of CFU count. SIGNIFICANCE AND IMPACT OF THE STUDY: Differences in Legionella colonization between types of buildings are not due to a variation in water supply but to other factors. Besides the importance of water recirculation, the study demonstrates the inhibiting action of copper and the favourable action of TOC on the development of L. pneumophila.  相似文献   

16.
Contamination of hospital water systems with legionellae is a well-known cause of nosocomial legionellosis. We describe a new real-time LightCycler PCR assay for quantitative determination of legionellae in potable water samples. Primers that amplify both a 386-bp fragment of the 16S rRNA gene from Legionella spp. and a specifically cloned fragment of the phage lambda, added to each sample as an internal inhibitor control, were used. The amplified products were detected by use of a dual-color hybridization probe assay design and quantified with external standards composed of Legionella pneumophila genomic DNA. The PCR assay had a sensitivity of 1 fg of Legionella DNA (i.e., less than one Legionella organism) per assay and detected 44 Legionella species and serogroups. Seventy-seven water samples from three hospitals were investigated by PCR and culture. The rates of detection of legionellae were 98.7% (76 of 77) by the PCR assay and 70.1% (54 of 77) by culture; PCR inhibitors were detected in one sample. The amounts of legionellae calculated from the PCR results were associated with the CFU detected by culture (r = 0.57; P < 0.001), but PCR results were mostly higher than the culture results. Since L. pneumophila is the main cause of legionellosis, we further developed a quantitative L. pneumophila-specific PCR assay targeting the macrophage infectivity potentiator (mip) gene, which codes for an immunophilin of the FK506 binding protein family. All but one of the 16S rRNA gene PCR-positive water samples were also positive in the mip gene PCR, and the results of the two PCR assays were correlated. In conclusion, the newly developed Legionella genus-specific and L. pneumophila species-specific PCR assays proved to be valuable tools for investigation of Legionella contamination in potable water systems.  相似文献   

17.
Shower heads and hot-water faucets containing Legionella pneumophila were evaluated for aerosolization of the organism with a multistage cascade impaction air sampler. Air was collected above two shower doors and from the same rooms approximately 3 ft (91 cm) from the shower doors while the hot water was running. Low numbers (3 to 5 CFU/15 ft3 [0.43 m3] of air) of L. pneumophila were recovered above both shower doors, but none was recovered from the air in either room outside the shower door. Approximately 90% (7 of 8 CFU) of the L. pneumophila recovered were trapped in aerosol particles between 1 and 5 micron in diameter. Air was collected 1 to 3 ft (30 to 91 cm) from 14 sinks while the hot water was running. Low numbers (1 to 5 CFU/15 ft3 of air) were recovered from 6 of 19 air samples obtained. Approximately 50% (6 of 13 CFU) of the organisms recovered were trapped in aerosol particles between 1 and 8 microns in diameter. Shower heads and hot-water taps containing L. pneumophila can aerosolize low numbers of the organism during routine use. The aerosol particle size is small enough to penetrate to the lower human respiratory system. Thus, these sites may be implicated as a means of transmission of L. pneumophila from potable water to the patient.  相似文献   

18.
Shower heads and hot-water faucets containing Legionella pneumophila were evaluated for aerosolization of the organism with a multistage cascade impaction air sampler. Air was collected above two shower doors and from the same rooms approximately 3 ft (91 cm) from the shower doors while the hot water was running. Low numbers (3 to 5 CFU/15 ft3 [0.43 m3] of air) of L. pneumophila were recovered above both shower doors, but none was recovered from the air in either room outside the shower door. Approximately 90% (7 of 8 CFU) of the L. pneumophila recovered were trapped in aerosol particles between 1 and 5 micron in diameter. Air was collected 1 to 3 ft (30 to 91 cm) from 14 sinks while the hot water was running. Low numbers (1 to 5 CFU/15 ft3 of air) were recovered from 6 of 19 air samples obtained. Approximately 50% (6 of 13 CFU) of the organisms recovered were trapped in aerosol particles between 1 and 8 microns in diameter. Shower heads and hot-water taps containing L. pneumophila can aerosolize low numbers of the organism during routine use. The aerosol particle size is small enough to penetrate to the lower human respiratory system. Thus, these sites may be implicated as a means of transmission of L. pneumophila from potable water to the patient.  相似文献   

19.
The objective of this study was to develop and optimize a protocol for the rapid detection of Escherichia coli O157:H7 in aqueous samples by a combined immunomagnetic bead-immunoliposome (IMB/IL) fluorescence assay. The protocol consisted of the filtration or centrifugation of 30- to 100-ml samples followed by incubation of the filter membranes or pellet with anti-E. coli O157:H7 immunomagnetic beads in growth medium specific for E. coli O157:H7. The resulting E. coli O157:H7-immunomagnetic bead complexes were isolated by magnetic separation, washed, and incubated with sulforhodamine B-containing immunoliposomes specific for E. coli O157:H7; the final immunomagnetic bead-E. coli O157:H7-immunoliposome complexes were again isolated by magnetic separation, washed, and lysed with a n-octyl-beta-d-glucopyranoside to release sulforhodamine B. The final protocol took less than 8 h to complete and had a detection limit of less than 1 CFU of E. coli O157:H7 per ml in various aqueous matrices, including apple juice and cider. To validate the protocol at an independent facility, 100-ml samples of groundwater with and without E. coli O157:H7 (15 CFU) were analyzed by a public health laboratory using the optimized protocol and a standard microbiological method. While the IMB/IL fluorescence assay was able to identify E. coli O157:H7-containing samples with 100% accuracy, the standard microbiological method was unable to distinguish E. coli O157:H7-spiked samples from negative controls without further extensive workup. These results demonstrate the feasibility of using immunomagnetic beads in combination with sulforhodamine B-encapsulating immunoliposomes for the rapid detection of E. coli O157:H7 in aqueous samples.  相似文献   

20.
Using fluorescence in situ hybridization to detect bacterial groups has several inherent limitations. DNA probes are generally used, targeting sites on the 16S rRNA. However, much of the 16S rRNA is highly conserved, with variable regions often located in inaccessible areas where secondary structures can restrict probe access. Here, we describe the use of peptide nucleic acid (PNA) probes as a superior alternative to DNA probes, especially when used for environmental samples. A complex bacterial genus (Legionella) was studied, and two probes were designed, one to detect all species and one targeted to Legionella pneumophila. These probes were developed from existing sequences and are targeted to low-binding-affinity sites on the 16S rRNA. In total, 47 strains of Legionella were tested. In all cases, the Legionella spp. PNA probe labeled cells strongly but did not bind to any non-Legionella species. Likewise, the specific L. pneumophila PNA probe labeled only strains of L. pneumophila. By contrast, the equivalent DNA probes performed poorly. To assess the applicability of this method for use on environmental samples, drinking-water biofilms were spiked with a known concentration of L. pneumophila bacteria. Quantifications of the L. pneumophila bacteria were compared using PNA hybridization and standard culture methods. The culture method quantified only 10% of the number of L. pneumophila bacteria found by PNA hybridization. This illustrates the value of this method for use on complex environmental samples, especially where cells may be in a viable but noncultivable state.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号