首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The effect of acetylcholinesterase (AChE) immobilization over the surface of a quartz crystal microbalance (QCM), by chemisorption of the AChE thiolated with a heterobifunctional cross-linker, sulfo-succinimidyl-6-[3-(2-pyridyldithio)propionamido]hexanoate, and carboxyl-amine coupling of AChE to 3-mercaptopropionic acid self-assembled monolayer, on the responses of a batch-type QCM-precipitation sensor was compared, resulting in a better sensitivity and binding efficiency in the former method. When an inhibition study with the developed sensor was undertaken at the optimized AChE immobilization with varying concentrations of a model organophosphorus pesticide EPN and carbamate one carbofuran, a sensitive detection for them was possible with the limit of detection corresponding to 1.55 x 10(-8) and 1.30 x 10(-9)M, respectively.  相似文献   

2.
Engineered variants of Drosophila melanogaster acetylcholinesterase (AChE) were used as biological receptors of AChE-multisensors for the simultaneous detection and discrimination of binary mixtures of cholinesterase-inhibiting insecticides. The system was based on a combination of amperometric multielectrode biosensors with chemometric data analysis of sensor outputs using artificial neural networks (ANN). The multisensors were fully manufactured by screen-printing, including enzyme immobilisation. Two types of multisensors were produced that consisted of four AChE variants each. The AChE mutants were selected in order to obtain high resolution, enhanced sensitivity and minimal assay time. This task was successfully achieved using multisensor I equipped with wild-type Drosophila AChE and mutants Y408F, F368L, and F368H. Each of the AChE variants was selected on the basis of displaying an individual sensitivity pattern towards the target analytes. For multisensor II, the inclusion of F368W, which had an extremely diminished paraoxon sensitivity, increased the sensor's capacity even further. Multisensors I and II were both used for inhibition analysis of binary paraoxon and carbofuran mixtures in a concentration range 0-5 microg/l, followed by data analysis using feed-forward ANN. The two analytes were determined with prediction errors of 0.4 microg/l for paraoxon and 0.5 microg/l for carbofuran. A complete biosensor assay and subsequent ANN evaluation was completed within 40 min. In addition, multisensor II was also investigated for analyte discrimination in real water samples. Finally, the properties of the multisensors were confirmed by simultaneous detection of binary organophosphate mixtures. Malaoxon and paraoxon in composite solutions of 0-5 microg/l were discriminated with predication errors of 0.9 and 1.6 microg/l, respectively.  相似文献   

3.
Liquid and gas chromatography are commonly used to measure organophosphorus pesticides. However, these methods are relatively time consuming and require a tedious sample pretreatment. Here, we applied the localized surface plasmon resonance (LSPR) of gold nanoparticles covalently coupled with acetylcholinesterase (AChE) to create a biosensor for detecting an example of serial signals responding to paraoxon in the range of 1-100 ppb by an AChE modified LSPR sensor immersing in a 0.05 mM ACh solution. The underlying mechanism is that paraoxon prevents acetylcholine chloride (ACh) reacting with AChE by destroying the OH bond of serine in AChE. We found that the AChE modified LSPR sensors prepared by incubation with 12.5 mU/mL of AChE in phosphate buffer solution at pH 8.5 room temperature for 14 h have the best linear inhibition response with a 0.234 ppb limit of paraoxon detection. A 14% of inhibition on the sensor corresponds to the change of paraoxon concentration from 1 to 100 ppb. The sensor remained 94% of its original activity after six cycles of inhibition with 500 ppb paraoxon followed with reactivation of AChE by 0.5 mM 2-pyriding-aldoxime methoiodide (2-PAM). In addition, the sensor retains activity and gives reproducible results after storage in dry state at 4 degrees C for 60 days. In conclusion, we demonstrated that the AChE modified LSPR sensors can be used to determine the concentration of paraoxon biosensor with high sensitive and stable characteristics.  相似文献   

4.
This paper reports site-specific affinity immobilization of (His)6-tagged acetylcholinesterase (AChE) onto Ni/NiO nanoparticles for the development of an electrochemical screen-printed biosensor for the detection of organophosphate pesticides. The method is based on the specific affinity binding of the His-tagged enzyme to oxidized nickel nanoparticle surfaces in the absence of metal chelators. This approach allows stable and oriented attachment of the enzyme onto the oxidized nickel through the external His residue in one-step procedure, allowing for fast and sensitive detection of paraoxon in the concentration range from 10−8 to 10−13 M. A detection limit of 10−12 M for paraoxon was obtained after 20 min incubation. This method can be used as a generic approach for the immobilization of other His-tagged enzymes for the development of biosensors.  相似文献   

5.
Nicotiana benthamiana plant lines expressing a reengineered human butyrylcholinesterase (BChE) with enhanced cocaine hydrolase activity were created. Subsequent purification and biochemical analysis revealed that compared to wild-type butyrylcholinesterase, the cocaine hydrolase displayed increased affinity to the organophosphate (OP) pesticides paraoxon (6.84x10(-10)M vs. 1.11x10(-8)M) and malaoxon (9.81x10(-8)M vs. 5.99x10(-7)M). Furthermore, the cocaine hydrolase retained identical anticholinesterase binding profiles for all other compounds tested. Thus we have demonstrated a potential large-scale production platform for a multivalent antidote for cocaine and anticholinesterase poisoning.  相似文献   

6.
A dimeric Cu(II) complex [Cu(μ(2)-hep)(hep-H)](2)·2ClO(4) (1) containing bidentate (hep-H=2-(2-hydroxyethyl)pyridine) ligand was synthesized and characterized by single crystal X-ray diffraction studies. Each Cu-ion in 1 is in a distorted square pyramidal geometry. Further 1 along with silver nanoparticles (SNPs) have been used as modifier in the construction of a biomimetic sensor (1-SNP-GCPE) for determining certain catecholamines viz., dopamine (DA), levodopa (l-Dopa), epinephrine (EP) and norepinephrine (NE) using cyclic voltammetry, chronocoulometry, electrochemical impedance spectroscopy and adsorptive stripping square wave voltammetry (AdSSWV). Finally, the catalytic properties of the sensor were characterized by chronoamperometry. Employing AdSSWV, the calibration curves showed linear response ranging between 10(-6) and 10(-9)M for all the four analytes with detection limits (S/N=3) of 8.52×10(-10)M, 2.41×10(-9)M, 3.96×10(-10)M and 3.54×10(-10)M for DA, l-Dopa, EP and NE respectively. The lifetime of the biomimetic sensor was 3 months at room temperature. The prepared modified electrode shows several advantages such as simple preparation method, high sensitivity, high stability, ease of preparation and regeneration of the electrode surface by simple polishing along with excellent reproducibility. The method has been applied for the selective and precise analysis of DA, l-Dopa, EP and NE in pharmaceutical formulations, urine and blood serum samples.  相似文献   

7.
This work describes the development of an automated flow-based biosensor that employs genetically modified acetylcholinesterase (AChE) enzymes B394, B4 and wild type B131. The biosensor was based on a screen printed carbon electrode (SPE) that was integrated into a flow cell. Enzymes were immobilised on cobalt (II) phthalocyanine (CoPC) modified electrodes by entrapment in a photocrosslinkable polymer (PVA-AWP). The automated flow-based biosensor was successfully used to quantify three organophosphate pesticides (OPs) in milk samples. The OPs used were chlorpyriphos-oxon (CPO), ethyl paraoxon (EPOx) and malaoxon (MOx). The total analysis time for the assay was less than 15 min. Initially, the biosensor performance was tested in phosphate buffer solution (PBS) using B394, B131 and B4 biosensors. The best detection limits were obtained with B394; therefore, this biosensor was used to produce calibration data in milk with three OPs in the concentration range of 5 × 10(-6)M to 5 × 10(-12)M. The limit of detection (LOD) obtained in milk for CPO, EPOx and MOx were 5 × 10(-12)M, 5 × 10(-9)M and 5 × 10(-10)M, respectively, with a correlation coefficient R(2)=0.9910. The automated flow-based biosensor successfully quantified the OPs in different fat-containing milk samples. There were no false positives or false negatives observed for the analytical figures of merit for the constructed biosensors. This method is inexpensive, sensitive, portable, non-invasive and provides real-time results. This analytical system can provide rapid detection of highly toxic OPs in food matrices such as milk.  相似文献   

8.
Eleven unique monoclonal IgG antibodies were raised against rabbit brain acetylcholinesterase (AChE, EC 3.1.1.7), purified to electrophoretic homogeneity by a two-step procedure involving immunoaffinity chromatography. The apparent dissociation constants of these antibodies for rabbit AChE ranged from about 10 nM to more than 100 nM (assuming one binding site per catalytic subunit). Species cross-reactivity was investigated with crude brain extracts from rabbit, rat, mouse cat, guinea pig, and human. One antibody bound rabbit AChE exclusively; most bound AChE from three or four species; two bound enzyme from all species tested. Identical, moderate affinity for rat and mouse brain AChE was displayed by two antibodies; two others were able to distinguish between these similar antigens. Nine of the antibodies had lowered affinity for AChE in the presence of 1 M NaCl, but two were salt resistant. Analysis of mutual interferences in AChE binding suggested that certain of the antibodies were competing for nearby epitopes on the AChE surface. One antibody was a potent AChE inhibitor (IC50 = 10(-8) M), blocking up to 90% of the enzyme activity. Most of the antibodies were less able to bind the readily soluble AChE of detergent-free brain extracts than the AChE which required detergent for solubilization. The extreme case, an antibody that was unable to recognize nearly half of the "soluble" AChE, was suspected of lacking affinity for the hydrophilic enzyme form.  相似文献   

9.
An aptamer is an artificial functional oligonucleic acid, which can interact with its target molecule with high affinity and specificity. Enzyme linked aptamer assay (ELAA) is developed to detect cocaine using aptamer fragment/cocaine configuration based on the affinity interaction between aptamer fragments with cocaine. The aptasensor was constructed by cleaving anticocaine aptamer into two fragments: one was assembled on a gold electrode surface, while the other was modified with biotin at 3'-end, which could be further labelled with streptavidin-horseradish peroxidase (SA-HRP). Upon binding with cocaine, the HRP-labelled aptamer fragment/cocaine complex formed on the electrode would increase the reduction current of hydroquinone (HQ) in the presence of H(2)O(2). The sensitivity and the specificity of the proposed electrochemical aptasensor were investigated by differential pulse voltammetry (DPV). The results indicated that the DPV signal change could be used to sensitively detect cocaine with the dynamic range from 0.1 μM to 50 μM and the detection limit down to 20 nM (S/N=3). The proposed aptasensor has the advantages of high sensitivity and low background current. Furthermore, a new configuration for ELAA requiring only a single aptamer sequence is constructed, which can be generalized for detecting different kinds of targets by cleaving the aptamers into two suitable segments.  相似文献   

10.
Sol-gel technique has been used for the covalent immobilization of the water-soluble mediator, thionin to construct a bulk modified, leak free composite electrode. This renewable composite electrode provides stable immobilization matrix for thionin via glutaraldehyde crosslinking. In the electrode composition the sol-gel precursor 3-aminopropyltrimethoxy silane serves as the host for immobilization of thionin, thereby preventing its leakage. An additional precursor methyl trimethoxy silane endows hydrophobicity and limits the wetting section of the modified electrode. Cyclic voltammetric characterization of the modified electrode in the potential range of 0.2 to -0.6 V exhibited stable redox peaks with a formal potential of -0.273 V, corresponding to immobilized thionin. This chemically modified electrode exhibits good electrocatalytic activity for the reduction of H(2)O(2) at a lower potential of -0.35 V. The reduction current of the modified electrode increases linearly in the range of 3.44 x 10(-6)M to 3.07 x 10(-3)M H(2)O(2) with a detection limit of 1.38 x 10(-6)M. The stable and quick response (5s) during chronoamperometry shows the potential application of the modified electrode for flow system analysis. The low potential operation (-0.35 V) favoured selective determination of H(2)O(2). The composite electrode exhibits distinct advantages of polishing in the event of surface fouling as well as simple preparation, good chemical and mechanical stability, economical and remarkable long-term stability (more than 1 year). The applicability of the present sensor for H(2)O(2) determination proposes a method for the detection of other biologically significant analytes.  相似文献   

11.
Acetylcholinesterase (AChE) inhibitors are potentially lethal but also have applications as therapeutic drugs for neurodegenerative diseases such as Alzheimer’s. Enzyme inhibitor binding are difficult to be detected directly by surface plasmon resonance (SPR) due to their small molecular weight. In this article, we describe the detection of AChE inhibitor binding by SPR without the use of competitive binding or antibodies. AChE was immobilized on the gold surface of an SPR sensor through covalent attachment to a self-assembled monolayer (SAM) of a COOH-terminated alkanethiol. The activity of the immobilized protein and the surface density were determined by using a standard photometric assay. Binding of two reversible inhibitors, which are used as therapeutic drugs, was detectable by SPR without the need to further modify the surface or the use of other reagents. The binding affinities (KA) obtained from the fits were 3.8 × 103 M−1 for neostigmine and 1.7 × 103 M−1 for eserine, showing a higher affinity of the sensor for neostigmine. We believe that the SPR sensor’s ability to detect these inhibitors is due to conformational changes of the enzyme structure on inhibitor binding.  相似文献   

12.
A simple, label-free electrochemical impedance-spectroscopy method for sequence-specific detection of DNA using a 4-aminoethylbenzenediazonium (AEBD) salt as a binder for amino-modified probe DNA is reported. This novel method simplifies the anchoring of DNA at the GC surface and opens new ways for the detection of hybridization. The hybridization of target DNA, without and with mismatches, with the probe DNA anchored at the GC surface modified with AEBD, greatly increases the interfacial electron transfer resistance at the double-stranded DNA modified electrodes for the redox couple Fe(CN)(6)(3-/4-). The resistance was measured using electrochemical impedance spectroscopy. The sensor response increased linearly with logarithm of concentration of target DNA in the range 2×10(-12)÷2×10(-6) M. The obtained quantification limit was circa 6.5×10(-17) mole in a 7 μL droplet and corresponded to a concentration of 9.2×10(-12) M of target DNA in the sample. This limit is equivalent to the detection of circa 4×10(7) copies of DNA in a 7 μL droplet or circa 5.7×10(12) DNA copies in one litre of sample.  相似文献   

13.
A potentiometric chemosensor for selective determination of dipicolinic acid (2,6-pyridinedicarboxylic acid, DPA) was developed based on the surface imprinting technique coupled with a nanoscale transducer: an indium tin oxide (ITO)-coated glass plate. The sensor fabrication conditions, optimal recognition condition, as well as selectivity, sensitivity, and stability of the DPA sensor have been investigated. The DPA sensor could recognize DPA from 3,5-pyridinedicarboxylic acid. Potentiometric measurements demonstrated selective detection of DPA in a concentration range of 1.5 x 10(-6) to 0.0194 M. The response time of DPA sensor for 4 x 10(-4) M DPA was 25 s. The potentiometric response of the DPA sensor to DPA is at 90% of its initial magnitude after 550 times measurement. The viability of such a modified ITO electrode in the presence of other inorganic, organic, and biological materials was probed.  相似文献   

14.
A voltammetric ion-channel sensing for phosphate based on gold electrodes modified with the self-assembled monolayers of a bis-thiourea receptor was developed to detect phosphate. The working principle of this voltammetric sensor conceptually mimics that of ligand gated ion-channel proteins, as to chemically stimulated changes in membrane permeability. The response to analytes is based on the change in electron transfer rate constant of the redox reaction of [Fe(CN)(6)](4-/3-) marker, before and after binding of phosphate to the receptor on the electrode surface; where the electrostatic repulsion between a phosphate-receptor complex and the marker induced the decrease in the rate constant. In a solution of pH 7.0, a high selectivity was observed for phosphate and the sensor was virtually insensitive at all to many of other anions, such as SO(4)(2-), AcO(-), NO(3)(-), and Cl(-). The sensor response was obtained with phosphate concentrations above 5.0 x 10(-4) M using cyclic voltammetry and differential pulse voltammetry.  相似文献   

15.
We have developed a simple assay method for the evaluation of estrogen receptor (ER) binding capacity of chemicals without the use of radio- or fluorescence-labeled compounds. We used the solution competition assay by the BIACORE biosensor, a surface plasmon resonance biosensor, with estradiol as a ligand, human recombinant ER(alpha) (hrER(alpha)) as a high molecular weight (hmw) interactant and test chemicals as analytes. For the ligand, aminated estradiol with a spacer molecule (E2-17PeNH) was synthesized and immobilized on a carboxymethyl dextran-coated sensor chip by the amine coupling method. The injection of the hmw interactant hrER(alpha) to the biosensor raised the sensorgram, indicating its binding to the ligand E2-17PeNH. The binding of test chemicals to hrERalpha was determined as a reduction in the hrER(alpha) binding to E2-17PeNH. The dissociation constant for the binding to hrER(alpha) was calculated for estrone (4.29 x 10(-9)M), estradiol (4.04 x 10(-10)M), estriol (8.35 x 10(-10)M), tamoxifen (2.16 x 10(-8)M), diethylstilbestrol (1.46 x 10(-10)M), bisphenol A (1.35 x 10(-6)M) and 4-nonylphenol (7.49 x 10(-6)M), by plotting the data according to an equation based on mass action law. This method can also be used as a high throughput screening method.  相似文献   

16.
Rapid and sensitive biosensor for Salmonella   总被引:2,自引:0,他引:2  
The rapid and sensitive detection of Salmonella typhymurium based on the use of a polyclonal antibody immobilized by the Langmuir-Blodgett method on the surface of a quartz crystal acoustic wave device was demonstrated. The binding of bacteria to the surface changed the crystal resonance parameters; these were quantified by the output voltage of the sensor instrumentation. The sensor had a lower detection limit of a few hundred cells/ml, and a response time of < 100 s over the range of 10(2)-10(10) cells/ml. The sensor response was linear between bacterial concentrations of 10(2)-10(7) cells/ml, with a sensitivity of 18 mV/decade. The binding of bacteria was specific with two binding sites needed to bind a single cell. The sensors preserve approximately 75% of their sensitivity over a period of 32 days.  相似文献   

17.
A chemically modified electrode constructed by incorporating iron(II) phthalocyanine [Fe(II)Pc] into carbon-paste matrix was used as a sensitive potentiometric sensor for detection of ascorbic acid. The resulting electrode exhibits catalytic properties for the electrooxidation of ascorbic acid, and lowers the overpotential for the oxidation of this compound. The faster rate of electron transfer results in a near-Nernstian behavior of the modified electrode, and makes it a suitable potentiometric sensor for detection of ascorbic acid. A linear response in concentration range from 10(-6) to 10(-2) M (0.18--1800 microg ml(-1)) was obtained with a detection limit of 5 x 10(-7) M for the potentiometric detection of ascorbic acid. The modified electrode was used for the determination of ascorbic acid in vitamin preparations. The recovery was 97.2--102.4% for the vitamin added to the preparations with a relative standard deviation of less than 5%. The modified electrode exhibited a fast response time (<10 s),had good stability, and had an extended lifetime.  相似文献   

18.
A biosensor system based on total internal reflectance fluorescence (TIRF) was used to discriminate a mixture of the triazines atrazine and simazine. Only cross-reactive antibodies were available for these two analytes. The biosensor is fully automated and can be regenerated allowing several hundreds of measurements without any user input. Even a remote control for online monitoring in the field is possible. The multivariate calibration of the sensor signal was performed using artificial neural networks, as the relationship between the sensor signals and the concentration of the analytes is highly non-linear. For the development of a multi-analyte immunoassay consisting of two polyclonal antibodies with cross-reactivity to atrazine and simazine and different derivatives immobilised on the transducer surface, the binding characteristics between these substances like binding capacity and cross-reactivity were characterised. The examination of three different measurement procedures showed that a two-step measurement using only one antibody per step allows a quantification of both analytes in a mixture with limits of detection of 0.2 microg/l for atrazine and 0.3 microg/l for simazine. The biosensor is suitable for online monitoring in the field and remote control is possible.  相似文献   

19.
We developed a highly sensitive flow injection/amperometric biosensor for the detection of organophosphate pesticides (OPs) using layered double hydroxides (LDHs) as the immobilization matrix of acetylcholinesterase (AChE). LDHs provided a biocompatible microenvironment to keep the bioactivity of AChE, due to the intrinsic properties of LDHs (such as a regular structure, good mechanical, chemical and thermal stabilities, and swelling properties). By integrating the flow injection analysis (FIA) with amperometric detection, the resulting AChE-LDHs modified electrode greatly catalyzed the oxidation of the enzymatically generated thiocholine product, and facilitated the detection automation, thus increasing the detection sensitivity. The analytical conditions for the FIA/amperometric detection of OPs were optimized by using methyl parathion (MP) as a model. The inhibition of MP was proportional to its concentration ranging from 0.005 to 0.3μgmL(-1) and 0.3 to 4.0μgmL(-1) with a detection limit 0.6ngmL(-1) (S/N=3). The developed biosensor exhibited good reproducibility and acceptable stability.  相似文献   

20.
We demonstrated a new strategy for highly sensitive electrochemical detection of cocaine by using two engineered aptamers in connection to redox-recycling signal amplification. The graphene/AuNP nanocomposites were electrochemically deposited on a screen printed carbon electrode to enhance the electron transfers. The cocaine primary binding aptamers were self-assembled on the electrode surface through sulfur-Au interactions. The presence of the target cocaine and the biotin-modified secondary binding aptamers leads to the formation of sandwich complexes on the electrode surface. The streptavidin-conjugated alkaline phosphatases (ALPs) were used as labels to generate quantitative signals. The addition of the ALP substrate and the co-reactant NADH results in the formation of a redox cycle between the enzymatic product and the electrochemically oxidized species and the signal is thus significantly amplified. Because of the effective modification of the sensing surface and signal amplification, low nanomolar (1 nM) detection limit for cocaine is achieved. The proposed aptamer-based sandwich sensing approach for amplified detection of cocaine thus opens new opportunities for highly sensitive determination of other small molecules.  相似文献   