首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A detailed 3D anatomical model of the patellofemoral joint was developed to study the tracking, force, contact and stability characteristics of the joint. The quadriceps was considered to include six components represented by 15 force vectors. The patellar tendon was modeled using four bundles of viscoelastic tensile elements. Each of the lateral and medial retinaculum was modeled by a three-bundle nonlinear spring. The femur and patella were considered as rigid bodies with their articular cartilage layers represented by an isotropic viscoelastic material. The geometrical and tracking data needed for model simulation, as well as validation of its results, were obtained from an in vivo experiment, involving MR imaging of a normal knee while performing isometric leg press against a constant 140 N force. The model was formulated within the framework of a rigid body spring model and solved using forth-order Runge-Kutta, for knee flexion angles between zero and 50 degrees. Results indicated a good agreement between the model predictions for patellar tracking and the experimental results with RMS deviations of about 2 mm for translations (less than 0.7 mm for patellar mediolateral shift), and 4 degrees for rotations (less than 3 degrees for patellar tilt). The contact pattern predicted by the model was also consistent with the results of the experiment and the literature. The joint contact force increased linearly with progressive knee flexion from 80 N to 210 N. The medial retinaculum experienced a peak force of 18 N at full extension that decreased with knee flexion and disappeared entirely at 20 degrees flexion. Analysis of the patellar time response to the quadriceps contraction suggested that the muscle activation most affected the patellar shift and tilt. These results are consistent with the recent observations in the literature concerning the significance of retinaculum and quadriceps in the patellar stability.  相似文献   

2.
Knee osteoarthritis (OA) is believed to result from high levels of contact stresses on the articular cartilage and meniscus after meniscal damage. This study investigated the effect of meniscal tears and partial meniscectomies on the peak compressive and shear stresses in the human knee joint. An elaborate three-dimensional finite element model of knee joint including bones, articular cartilages, menisci and main ligaments was developed from computed tomography and magnetic resonance imaging images. This model was used to model four types of meniscal tears and their resultant partial meniscectomies and analysed under an axial 1150 N load at 0° flexion. Three different conditions were compared: a healthy knee joint, a knee joint with medial meniscal tears and a knee joint following partial meniscectomies. The numerical results showed that each meniscal tear and its resultant partial meniscectomy led to an increase in the peak compressive and shear stresses on the articular cartilages and meniscus in the medial knee compartment, especially for partial meniscectomy. Among the four types of meniscal tears, the oblique tear resulted in the highest values of the peak compressive and shear stresses. For the four partial meniscectomies, longitudinal meniscectomy led to the largest increase in these two stresses. The lateral compartment was minimally affected by all the simulations. The results of this study demonstrate meniscal tear and its resultant partial meniscectomy has a positive impact on the maintenance of high levels of contact stresses, which may improve the progression of knee OA, especially for partial meniscectomy. Surgeons should adopt a prudent strategy to preserve the greatest amount of meniscus possible.  相似文献   

3.
The present investigation of fiber arrangement in the collateral ligaments of the knee was carried out in cats and man in various positions of flexion and extension, without compression load. In all knee joint positions, the fibers of the collateral ligaments are twisted except for the fibers in the meniscal part of the medial collateral ligament which have a parallel arrangement. Furthermore, most of the fibers in the collateral ligaments are taut in all positions of the knee joint in both cat and man. By means of planar models representing different fiber arrangements, the kinematic behavior of the collateral ligaments was analyzed. It appears that a crossed (twisted) arrangement of the fibers is most effective in rotatory movements, whereas a parallel orientation is most effective in translation. Our data further indicate that, in measuring the changes in lengths of ligaments during joint motion, one cannot neglect the internal arrangement of fibers and the geometry of the articular surfaces and menisci.  相似文献   

4.
A validated three-dimensional computational model of a human knee joint   总被引:7,自引:0,他引:7  
This paper presents a three-dimensional finite element tibio-femoral joint model of a human knee that was validated using experimental data. The geometry of the joint model was obtained from magnetic resonance (MR) images of a cadaveric knee specimen. The same specimen was biomechanically tested using a robotic/universal force-moment sensor (UFS) system and knee kinematic data under anterior-posterior tibial loads (up to 100 N) were obtained. In the finite element model (FEM), cartilage was modeled as an elastic material, ligaments were represented as nonlinear elastic springs, and menisci were simulated by equivalent-resistance springs. Reference lengths (zero-load lengths) of the ligaments and stiffness of the meniscus springs were estimated using an optimization procedure that involved the minimization of the differences between the kinematics predicted by the model and those obtained experimentally. The joint kinematics and in-situ forces in the ligaments in response to axial tibial moments of up to 10 Nm were calculated using the model and were compared with published experimental data on knee specimens. It was also demonstrated that the equivalent-resistance springs representing the menisci are important for accurate calculation of knee kinematics. Thus, the methodology developed in this study can be a valuable tool for further analysis of knee joint function and could serve as a step toward the development of more advanced computational knee models.  相似文献   

5.
Patterns of fibre elongation and orientation for the cruciate and collateral ligaments of the human knee joint and for the patellar tendon have not yet been established in three-dimensions. These patterns are essential for understanding thoroughly the contribution of these soft tissues to joint function and of value in surgical treatments for a more conscious assessment of the knee status. Measurements from 10 normal cadaver knees are here reported using an accurate surgical navigation system and consistent anatomical references, over a large flexion arc, and according to current recommended conventions. The contours of relevant sub-bundles were digitised over the corresponding origins and insertions on the bones. Representative fibres were calculated as the straight line segments joining the centroids of these attachment areas. The most isometric fibre was also taken as that whose attachment points were at the minimum change in length over the flexion arc. Changes in length and orientation of these fibres were reported versus the flexion angle. A good general repeatability of intra- and inter-specimens was found. Isometric fibres were found in the locations reported in the literature. During knee flexion, ligament sub-bundles slacken in the anterior cruciate ligament, and in the medial and lateral collateral ligaments, whereas they tighten in the posterior cruciate ligament. In each cruciate ligament the two compounding sub-bundles have different extents for the change in fibre length, and also bend differently from each other on both tibial planes. In the collateral ligaments and patellar tendon all fibres bend posteriorly. Patellar tendon underwent complex changes in length and orientation, on both the tibial sagittal and frontal planes. For the first time thorough and consistent patterns of geometrical changes are provided for the main knee ligaments and tendons after careful fibre mapping.  相似文献   

6.
7.

Background

The major connective tissues of the knee joint act in concert during locomotion to provide joint stability, smooth articulation, shock absorption, and distribution of mechanical stresses. These functions are largely conferred by the intrinsic material properties of the tissues, which are in turn determined by biochemical composition. A thorough understanding of the structure-function relationships of the connective tissues of the knee joint is needed to provide design parameters for efforts in tissue engineering.

Methodology/Principal Findings

The objective of this study was to perform a comprehensive characterization of the tensile properties, collagen content, and pyridinoline crosslink abundance of condylar cartilage, patellar cartilage, medial and lateral menisci, cranial and caudal cruciate ligaments (analogous to anterior and posterior cruciate ligaments in humans, respectively), medial and lateral collateral ligaments, and patellar ligament from immature bovine calves. Tensile stiffness and strength were greatest in the menisci and patellar ligament, and lowest in the hyaline cartilages and cruciate ligaments; these tensile results reflected trends in collagen content. Pyridinoline crosslinks were found in every tissue despite the relative immaturity of the joints, and significant differences were observed among tissues. Notably, for the cruciate ligaments and patellar ligament, crosslink density appeared more important in determining tensile stiffness than collagen content.

Conclusions/Significance

To our knowledge, this study is the first to examine tensile properties, collagen content, and pyridinoline crosslink abundance in a direct head-to-head comparison among all of the major connective tissues of the knee. This is also the first study to report results for pyridinoline crosslink density that suggest its preferential role over collagen in determining tensile stiffness for certain tissues.  相似文献   

8.
The fascicle material properties in bone-fascicle-bone units were determined for the anterior and posterior cruciate ligaments (ACL, PCL), the lateral collateral ligament (LCL) and the patellar tendon (PT) from three young human donor knees. Groups of fascicles from each tissue were isolated with intact bone ends and failed at a high strain rate in a saline bath at 37 degrees C. In each knee tested the load related material properties (linear modulus, maximum stress and energy density to maximum stress) for the patellar tendon were significantly larger than corresponding values for the cruciate and collateral ligaments. Bundles from different ligaments in the same knee were similar to each other in their mechanical behavior. In addition, no significant differences were present in the maximum strains recorded for any of the four tissue types examined. The results presented have implications in studies of ligament injury. They are also important in the design and use of synthetic and biological ligament replacements and in tissue and whole knee modeling.  相似文献   

9.
As a step towards developing a finite element model of the knee that can be used to study how the variables associated with a meniscal replacement affect tibio-femoral contact, the goals of this study were 1) to develop a geometrically accurate three-dimensional solid model of the knee joint with special attention given to the menisci and articular cartilage, 2) to determine to what extent bony deformations affect contact behavior, and 3) to determine whether constraining rotations other than flexion/extension affects the contact behavior of the joint during compressive loading. The model included both the cortical and trabecular bone of the femur and tibia, articular cartilage of the femoral condyles and tibial plateau, both the medial and lateral menisci with their horn attachments, the transverse ligament, the anterior cruciate ligament, and the medial collateral ligament. The solid models for the menisci and articular cartilage were created from surface scans provided by a noncontacting, laser-based, three-dimensional coordinate digitizing system with an root mean squared error (RMSE) of less than 8 microns. Solid models of both the tibia and femur were created from CT images, except for the most proximal surface of the tibia and most distal surface of the femur which were created with the three-dimensional coordinate digitizing system. The constitutive relation of the menisci treated the tissue as transversely isotropic and linearly elastic. Under the application of an 800 N compressive load at 0 degrees of flexion, six contact variables in each compartment (ie., medial and lateral) were computed including maximum pressure, mean pressure, contact area, total contact force, and coordinates of the center of pressure. Convergence of the finite element solution was studied using three mesh sizes ranging from an average element size of 5 mm by 5 mm to 1 mm by 1 mm. The solution was considered converged for an average element size of 2 mm by 2 mm. Using this mesh size, finite element solutions for rigid versus deformable bones indicated that none of the contact variables changed by more than 2% when the femur and tibia were treated as rigid. However, differences in contact variables as large as 19% occurred when rotations other than flexion/extension were constrained. The largest difference was in the maximum pressure. Among the principal conclusions of the study are that accurate finite element solutions of tibio-femoral contact behavior can be obtained by treating the bones as rigid. However, unrealistic constraints on rotations other than flexion/extension can result in relatively large errors in contact variables.  相似文献   

10.
Pattern of anterior cruciate ligament force in normal walking   总被引:6,自引:0,他引:6  
The goal of this study was to calculate and explain the pattern of anterior cruciate ligament (ACL) loading during normal level walking. Knee-ligament forces were obtained by a two-step procedure. First, a three-dimensional (3D) model of the whole body was used together with dynamic optimization theory to calculate body-segmental motions, ground reaction forces, and leg-muscle forces for one cycle of gait. Joint angles, ground reaction forces, and muscle forces obtained from the gait simulation were then input into a musculoskeletal model of the lower limb that incorporated a 3D model of the knee. The relative positions of the femur, tibia, and patella and the forces induced in the knee ligaments were found by solving a static equilibrium problem at each instant during the simulated gait cycle. The model simulation predicted that the ACL bears load throughout stance. Peak force in the ACL (303 N) occurred at the beginning of single-leg stance (i.e., contralateral toe off). The pattern of ACL force was explained by the shear forces acting at the knee. The balance of muscle forces, ground reaction forces, and joint contact forces applied to the leg determined the magnitude and direction of the total shear force acting at the knee. The ACL was loaded whenever the total shear force pointed anteriorly. In early stance, the anterior shear force from the patellar tendon dominated the total shear force applied to the leg, and so maximum force was transmitted to the ACL at this time. ACL force was small in late stance because the anterior shear forces supplied by the patellar tendon, gastrocnemius, and tibiofemoral contact were nearly balanced by the posterior component of the ground reaction.  相似文献   

11.
The knee ligaments and patellar tendon function in concert with each other and other joint tissues, and are adapted to their specific physiological function via geometry and material properties. However, it is not well known how the viscoelastic and quasi-static material properties compare between the ligaments. The purpose of this study was to characterize and compare these material properties between the knee ligaments and patellar tendon.Dumbbell-shaped tensile test samples were cut from bovine knee ligaments (ACL, LCL, MCL, PCL) and patellar tendon (PT) and subjected to tensile testing (n = 10 per ligament type). A sinusoidal loading test was performed at 8% strain with 0.5% strain amplitude using 0.1, 0.5 and 1 Hz frequencies. Subsequently, an ultimate tensile test was performed to investigate the stress-strain characteristics.At 0.1 Hz, the phase difference between stress and strain was higher in LCL compared with ACL, PCL and PT (p < 0.05), and at 0.5 Hz that was higher in LCL compared with all other ligaments and PT (p < 0.05). PT had the longest toe-region strain (p < 0.05 compared with PCL and MCL) and MCL had the highest linear and strain-dependent modulus, and toughness (p < 0.05 compared with ACL, LCL and PT).The results indicate that LCL is more viscous than other ligaments at low-frequency loads. MCL was the stiffest and toughest, and its modulus increased most steeply at the toe-region, possibly implying a greater amount of collagen. This study improves the knowledge about elastic, viscoelastic and failure properties of the knee ligaments and PT.  相似文献   

12.
13.
Partial meniscectomy is believed to change the biomechanics of the knee joint through alterations in the contact of articular cartilages and menisci. Although fluid pressure plays an important role in the load support mechanism of the knee, the fluid pressurization in the cartilages and menisci has been ignored in the finite element studies of the mechanics of meniscectomy. In the present study, a 3D fibril-reinforced poromechanical model of the knee joint was used to explore the fluid flow dependent changes in articular cartilage following partial medial and lateral meniscectomies. Six partial longitudinal meniscectomies were considered under relaxation, simple creep, and combined creep loading conditions. In comparison to the intact knee, partial meniscectomy not only caused a substantial increase in the maximum fluid pressure but also shifted the location of this pressure in the femoral cartilage. Furthermore, these changes were positively correlated to the size of meniscal resection. While in the intact joint, the location of the maximum fluid pressure was dependent on the loading conditions, in the meniscectomized joint the location was predominantly determined by the site of meniscal resection. The partial meniscectomy also reduced the rate of the pressure dissipation, resulting in even larger difference between creep and relaxation times as compared to the case of the intact knee. The knee joint became stiffer after meniscectomy because of higher fluid pressure at knee compression followed by slower pressure dissipation. The present study indicated the role of fluid pressurization in the altered mechanics of meniscectomized knees.  相似文献   

14.
The ligaments of the knee consist of fiber bundles with variable orientations, lengths and mechanical properties. In concept, however, these structures were too often seen as homogeneous structures, which are either stretched or slack during knee motions. In previous studies, we proposed a new structural concept of the ligaments of the knee. In this concept, the ligaments were considered as multi-bundle structures, with nonuniform mechanical properties and zero force lengths. The purpose of the present study was to verify this new concept.

For this purpose, laxity characteristics of a human knee joint were compared as measured in an experiment and predicted in a model simulation study. In the experiment, the varus-valgus and anterior-posterior laxities of a knee-joint specimen containing the ligaments and the articular surfaces only, were determined. From this knee-joint, geometric and mechanical parameters were derived to supply the parameters for a three-dimensional quasi-static knee-joint model. These parameters included (i) the three-dimensional insertion points of bundles, defined in the four major knee ligaments, (ii) the mechanical properties of these ligament, as functions of their relative insertion orientations and (iii) three-dimensional representations of the articular surfaces. With this model the experiments were simulated. If knee-model predictions and experimental results agree, then the multi-bundle ligament models are validated, at least with respect to their functional role in anterior-posterior and varus-valgus loading of the joint.

The model described the laxity characteristics in AP-translation and VV-rotation of the cadaveric knee-joint specimen reasonably well. Both display the same patterns of laxity changes during knee flexion. Only if a varus moment of 8 N m was applied and if the tibia was posteriorly loaded, did the model predict a slightly higher laxity than that measured experimentally.

From the model-experiment comparisons it was concluded that the proposed structural representations of the ligaments and their mechanical property distributions seem to be valid for studying the anterior-posterior and varus-valgus laxity characteristics of the human knee-joint.  相似文献   


15.
An anatomical dynamic model consisting of three body segments, femur, tibia and patella, has been developed in order to determine the three-dimensional dynamic response of the human knee. Deformable contact was allowed at all articular surfaces, which were mathematically represented using Coons' bicubic surface patches. Nonlinear elastic springs were used to model all ligamentous structures. Two joint coordinate systems were employed to describe the six-degrees-of-freedom tibio-femoral (TF) and patello-femoral (PF) joint motions using twelve kinematic parameters. Two versions of the model were developed to account for wrapping and nonwrapping of the quadriceps tendon around the femur. Model equations consist of twelve nonlinear second-order ordinary differential equations coupled with nonlinear algebraic constraint equations resulting in a Differential-Algebraic Equations (DAE) system that was solved using the Differential/Algebraic System Solver (DASSL) developed at Lawrence Livermore National Laboratory. Model calculations were performed to simulate the knee extension exercise by applying non-linear forcing functions to the quadriceps tendon. Under the conditions tested, both "screw home mechanism" and patellar flexion lagging were predicted. Throughout the entire range of motion, the medial component of the TF contact force was found to be larger than the lateral one while the lateral component of the PF contact force was found to be larger than the medial one. The anterior and posterior fibers of both anterior and posterior cruciate ligaments, ACL and PCL, respectively, had opposite force patterns: the posterior fibers were most taut at full extension while the anterior fibers were most taut near 90 degrees of flexion. The ACL was found to carry a larger total force than the PCL at full extension, while the PCL carried a larger total force than the ACL in the range of 75 degrees to 90 degrees of flexion.  相似文献   

16.
BackgroundOsteoarthritis (OA) of the knee joint is a degenerative process resulting in cartilage loss. Recent evidence suggests that OA is not merely a disease of cartilage but a disease of the entire knee joint and that inflammation may play an important role. OA has been associated with vitamin D deficiency. Vitamin D as an immunomodulator and anti-inflammatory agent may attenuate inflammation in the knee. The aim of this study was to assess the anti-inflammatory effect of vitamin D on inflammation in the knee.MethodsThis study was conducted with 13 microswine on a high cholesterol diet categorized into three groups of vitamin D-deficient, vitamin D-sufficient, and vitamin D supplementation. After 1 year, microswine were killed, and their knee joint tissues were harvested. Histological and immunofluorescence studies were carried out on the tissue specimens to evaluate the effect of vitamin D status.ResultsHistological and immunofluorescence studies of the knee joint tissues showed (1) increased inflammation in the knee joint tissues, (2) fatty infiltration in quadriceps muscle, patellar tendon, and collateral ligaments, and (3) chondrocyte clustering in the vitamin D-deficient and vitamin D-sufficient groups compared with the vitamin D supplementation group. Architectural distortion of the quadriceps muscle, patellar tendon, and collateral ligaments was also seen in the areas of inflammatory foci and fatty infiltration in the vitamin D-deficient group.ConclusionsDecreased inflammation and fatty infiltration in the vitamin D supplementation group suggest the potential role of vitamin D in attenuating inflammation and fatty infiltration as well as in protecting the architecture of the tissue in the knee joint.

Electronic supplementary material

The online version of this article (doi:10.1186/s13075-016-1099-6) contains supplementary material, which is available to authorized users.  相似文献   

17.
Three-dimensional mathematical model analysis of the patellofemoral joint   总被引:1,自引:0,他引:1  
This paper is concerned with a mathematical model analysis of the patellofemoral joint in the human knee, taking into account the articular surface geometry and mechanical properties of the ligament. It was made by the application of a computer-aided design theory (previously studied) and it was possible to express the articular surface geometries in a mathematical formulation and hence elucidate the joint movement mechanics. This method was then applied to a three-dimensional geometrical model of the patellofemoral joint. For the modelling of tendofemoral contact at large angles of knee flexion, the geodestic line theory was adopted. Applying the Newton-Raphson method and the Runge-Kutta Gil method to the model, variables such as patellar attitudes, patellofemoral contact force and tensile force of the patellar ligament for various knee flexion angles were computed. Applying the Hertzian elastic theory, contact stress was also computed. These results showed good agreement with the previously reported experimental results. As an application for the model, some parameter analyses were performed in terms of the contact stress variations and compared with those of the normal knee. The simulation results indicated that both the Q-angle increase and decrease increased contact stress, the patella alta showed undulating variations of stress while the patella infera showed little change of stress, and the tibial tuberositas elevation showed 20-30% reduction of stress.  相似文献   

18.
Knee injuries, especially those that affect the cruciate and lateral ligaments, are one of the most serious and frequent pathologies that affect the lower human extremity. Hence, the aim of this study is to develop a dynamic model for the lower extremity capable of estimating forces, forces in the cruciate and collateral ligaments and those normal to the articular cartilage, generated in the knee. The proposed model considers a four-bar mechanism in the knee, a spherical joint in the pelvis and a revolute one in the ankle. The four-bar mechanism is obtained by a synthesis process. The dynamic model includes the inertial properties of the femur, tibia, patella and the foot, the ground reaction force and the most important muscles in the knee. Muscle forces are estimated using an optimisation technique. Results from the application of the model on a real human task are presented.  相似文献   

19.
In the knee joint, interactions between instantaneous kinetics and kinematics associated with ligamentous and articular tissues are not fully understood. These structures may be represented by the instantaneous screw axis ($) (ISA) and static force vectors ($′). Geometric changes to the joint structure affecting motion have not been fully explained, especially after surgical reconstruction and replacement procedures. The ISA offers a joint-characterisation approach, which is dependent on the combined forces of ligaments, articular contacts and muscles. The standard four-bar linkage model in the sagittal plane demonstrates that the normal contact force and the lines of action of the cruciate ligaments always intersect at the centre of rotation of the joint. A kinematic knee model in which the articular surfaces in the lateral and medial compartments as well as the isometric fascicles in the engaged ligaments may be represented as five constraints in a one-degree-of-freedom parallel spatial mechanism. This study provides a theoretical foundation to elucidate the role of each of these elements in the control of the ISA. A recourse to the principle of virtual work explained through d'Alembert's principle for reducing a dynamics problem to an instantaneous static scenario allows screws to be applied to the biomechanics of human motion. The principle of reciprocity links these approaches together to explain the transmitting load between the tibia and the femur as well as the relative motion within the knee joint. A principal clinical implication of this study is the introduction of the reciprocal connection factor to evaluate knee kinematics and kinetics in one simple term, allowing the quantitative assessment of the outcome of knee-joint treatment and rehabilitation methods.  相似文献   

20.
Surgical reconstruction is generally recommended for posterior cruciate ligament (PCL) injuries; however, the use of grafts is still a controversial problem. In this study, a three-dimensional finite element model of the human tibiofemoral joint with articular cartilage layers, menisci, and four main ligaments was constructed to investigate the effects of graft strengths on knee kinematics and in-situ forces of PCL grafts. Nine different graft strengths with stiffness ranging from 0% (PCL rupture) to 200%, in increments of 25%, of an intact PCL’s strength were used to simulate the PCL reconstruction. A 100 N posterior tibial drawer load was applied to the knee joint at full extension. Results revealed that the maximum posterior translation of the PCL rupture model (0% stiffness) was 6.77 mm in the medial compartment, which resulted in tibial internal rotation of about 3.01°. After PCL reconstruction with any graft strength, the laxity of the medial tibial compartment was noticeably improved. Tibial translation and rotation were similar to the intact knee after PCL reconstruction with graft strengths ranging from 75% to 125% of an intact PCL. When the graft’s strength surpassed 150%, the medial tibia moved forward and external tibial rotation greatly increased. The in-situ forces generated in the PCL grafts ranged from 13.15 N to 75.82 N, depending on the stiffness. In conclusion, the strength of PCL grafts have has a noticeable effect on anterior-posterior translation of the medial tibial compartment and its in-situ force. Similar kinematic response may happen in the models when the PCL graft’s strength lies between 75% and 125% of an intact PCL.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号