首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Children who exhibit gait deviations often present a range of bone deformities, particularly at the proximal femur. Altered gait may affect bone growth and lead to deformities by exerting abnormal stresses on the developing bones. The objective of this study was to calculate variations in the hip joint contact forces with different gait patterns. Muscle and hip joint contact forces of four children with different walking characteristics were calculated using an inverse dynamic analysis and a static optimisation algorithm. Kinematic and kinetic analyses were based on a generic musculoskeletal model scaled down to accommodate the dimensions of each child. Results showed that for all the children with altered gaits both the orientation and magnitude of the hip joint contact force deviated from normal. The child with the most severe gait deviations had hip joint contact forces 30% greater than normal, most likely due to the increase in muscle forces required to sustain his crouched stance. Determining how altered gait affects joint loading may help in planning treatment strategies to preserve correct loading on the bone from a young age.  相似文献   

2.
Despite the importance of sliding contact in diarthrodial joints, only a limited number of studies have addressed this type of problem, with the result that the mechanical behavior of articular cartilage in daily life remains poorly understood. In this paper, a finite element formulation is developed for the sliding contact of biphasic soft tissues. The augmented Lagrangian method is used to enforce the continuity of contact traction and fluid pressure across the contact interface. The resulting method is implemented in the commercial software COMSOL Multiphysics. The accuracy of the new implementation is verified using an example problem of sliding contact between a rigid, impermeable indenter and a cartilage layer for which analytical solutions have been obtained. The new implementation's capability to handle a complex loading regime is verified by modeling plowing tests of the temporomandibular joint (TMJ) disc.  相似文献   

3.
We studied the dynamic behavior of finger joints during the contact period of tapping on a computer keyswitch, to characterize and parameterize joint function with a lumped-parameter impedance model. We tested the hypothesis that the metacarpophalangeal (MCP) and interphalangeal (IP) joints act similarly in terms of kinematics, torque, and energy production when tapping. Fifteen human subjects tapped with the index finger of the right hand on a computer keyswitch mounted on a two-axis force sensor, which measured forces in the vertical and sagittal planes. Miniature fiber-optic goniometers mounted across the dorsal side of each joint measured joint kinematics. Joint torques were calculated from endpoint forces and joint kinematics using an inverse dynamic algorithm. For each joint, a linear spring and damper model was fitted to joint torque, position, and velocity during the contact period of each tap (22 per subject on average). The spring-damper model could account for over 90% of the variance in torque when loading and unloading portions of the contact were separated, with model parameters comparable to those previously measured during isometric loading of the finger. The finger joints functioned differently, as illustrated by energy production during the contact period. During the loading phase of contact the MCP joint flexed and produced energy, whereas the proximal and distal IP joints extended and absorbed energy. These results suggest that the MCP joint does work on the interphalangeal joints as well as on the keyswitch.  相似文献   

4.
In using musculoskeletal models, researchers can calculate muscle forces, and subsequently joint contact forces, providing insight into joint loading and the progression of such diseases as osteoarthritis (OA). The purpose of this study was to estimate the knee contact force (KCF) in patients with varying degrees of OA severity using muscle forces and joint reaction forces derived from OpenSim. Walking data was obtained from healthy individuals (n=14) and those with moderate (n=10) and severe knee OA (n=2). For each subject, we generated 3D, muscle-actuated, forward dynamic simulations of the walking trials. Muscle forces that reproduced each subject’s gait were calculated. KCFs were then calculated using the vector sum of the muscle forces and joint reaction forces along the longitudinal axis of the femur. Moderate OA subjects exhibited a similar KCF pattern to healthy subjects, with lower second peaks (p=0.021). Although subjects with severe OA had similar initial peak KCF to healthy and moderate OA subjects (more than 4 times BW), the pattern of the KCF was very different between groups. After an initial peak, subjects with severe OA continually unloaded the joint, whereas healthy and moderate OA subjects reloaded the knee during late stance. In subjects with symmetric OA grades, there appears to be differences in loading between OA severities. Similar initial peaks of KCF imply that reduction of peak KCF may not be a compensatory strategy for OA patients; however, reducing duration of high magnitude loads may be employed.  相似文献   

5.
Robotic-assistive exoskeletons can enable frequent repetitive movements without the presence of a full-time therapist; however, human-machine interaction and the capacity of powered exoskeletons to attenuate shoulder muscle and joint loading is poorly understood. This study aimed to quantify shoulder muscle and joint force during assisted activities of daily living using a powered robotic upper limb exoskeleton (ArmeoPower, Hocoma). Six healthy male subjects performed abduction, flexion, horizontal flexion, reaching and nose touching activities. These tasks were repeated under two conditions: (i) the exoskeleton compensating only for its own weight, and (ii) the exoskeleton providing full upper limb gravity compensation (i.e., weightlessness). Muscle EMG, joint kinematics and joint torques were simultaneously recorded, and shoulder muscle and joint forces calculated using personalized musculoskeletal models of each subject’s upper limb. The exoskeleton reduced peak joint torques, muscle forces and joint loading by up to 74.8% (0.113 Nm/kg), 88.8% (5.8%BW) and 68.4% (75.6%BW), respectively, with the degree of load attenuation strongly task dependent. The peak compressive, anterior and superior glenohumeral joint force during assisted nose touching was 36.4% (24.6%BW), 72.4% (13.1%BW) and 85.0% (17.2%BW) lower than that during unassisted nose touching, respectively. The present study showed that upper limb weight compensation using an assistive exoskeleton may increase glenohumeral joint stability, since deltoid muscle force, which is the primary contributor to superior glenohumeral joint shear, is attenuated; however, prominent exoskeleton interaction moments are required to position and control the upper limb in space, even under full gravity compensation conditions. The modeling framework and results may be useful in planning targeted upper limb robotic rehabilitation tasks.  相似文献   

6.
Wrist loading patterns during pommel horse exercises   总被引:1,自引:0,他引:1  
Gymnastics is a sport which involves substantial periods of upper extremity support as well as frequent impacts to the wrist. Not surprisingly, wrist pain is a common finding in gymnasts. Of all events, the pommel horse is the most painful. In order to study the forces of wrist impact, a standard pommel horse was instrumented with a specially designed load cell to record the resultant force of the hand on the pommel during a series of basic skills performed by a group of seventeen elite male gymnasts. The highest mean peak forces were recorded during the front scissors and flair exercises (1.5 BW) with peaks of up to 2.0 BW for some gymnasts. The mean peak force for hip circles at the center or end of the horse was 1.1 BW. The mean overall loading rate (initial contact to first loading peak) ranged from 5.2 BWs-1 (hip circles) to 10.6 BW s-1 (flairs). However, many recordings displayed localized initial loading spikes which occurred during 'hard' landings on the pommel. When front scissors were performed in an aggressive manner, the initial loading spikes averaged 1.0 BW in magnitude (maximum 1.8 BW) with an average rise time of 8.2 ms; calculated localized loading rates averaged 129 BW s-1 (maximum 219 BW s-1). These loading parameters are comparable to those encountered at heel strike during running. These impact forces and loading rates are remarkably high for an upper extremity joint not normally exposed to weight-bearing loads, and may contribute to the pathogenesis of wrist injuries in gymnastics.  相似文献   

7.
The equine metacarpophalangeal (MCP) joint is frequently injured, especially by racehorses in training. Most injuries result from repetitive loading of the subchondral bone and articular cartilage rather than from acute events. The likelihood of injury is multi-factorial but the magnitude of mechanical loading and the number of loading cycles are believed to play an important role. Therefore, an important step in understanding injury is to determine the distribution of load across the articular surface during normal locomotion. A subject-specific finite-element model of the MCP joint was developed (including deformable cartilage, elastic ligaments, muscle forces and rigid representations of bone), evaluated against measurements obtained from cadaver experiments, and then loaded using data from gait experiments. The sensitivity of the model to force inputs, cartilage stiffness, and cartilage geometry was studied. The FE model predicted MCP joint torque and sesamoid bone flexion angles within 5% of experimental measurements. Muscle–tendon forces, joint loads and cartilage stresses all increased as locomotion speed increased from walking to trotting and finally cantering. Perturbations to muscle–tendon forces resulted in small changes in articular cartilage stresses, whereas variations in joint torque, cartilage geometry and stiffness produced much larger effects. Non-subject-specific cartilage geometry changed the magnitude and distribution of pressure and the von Mises stress markedly. The mean and peak cartilage stresses generally increased with an increase in cartilage stiffness. Areas of peak stress correlated qualitatively with sites of common injury, suggesting that further modelling work may elucidate the types of loading that precede joint injury and may assist in the development of techniques for injury mitigation.  相似文献   

8.
Polyethylene wear after total hip arthroplasty may occur as a result of normal gait and as a result of subluxation and relocation with impact. Relocation of a subluxed hip may impart a moment to the cup creating sliding as well as compression at the cup liner interface. The purpose of the current study is to quantify, by a validated finite element model, the forces generated in a hip arthroplasty as a result of subluxation relocation and compare them to the forces generated during normal gait. The micromotion between the liner and acetabular shell was quantified by computing the sliding track and the deformation at several points of the interface. A finite element analysis of polyethylene liner stress and liner/cup micromotion in total hip arthroplasty was performed under two dynamic profiles. The first profile was a gait loading profile simulating the force vectors developed in the hip arthroplasty during normal gait. The second profile is generated during subluxation and subsequent relocation of the femoral head. The forces generated by subluxation relocation of a total hip arthroplasty can exceed those forces generated during normal gait. The induced micromotion at the cup polyethylene interface as a result of subluxation can exceed micromotion as a result of the normal gait cycle. This may play a significant role in the generation of backsided wear. Minimizing joint subluxation by restoring balance to the hip joint after arthroplasty should be explored as a strategy to minimize backsided wear.  相似文献   

9.
The aim of this study was to determine the effects that soft tissue motion has on ground reaction forces, joint torques and joint reaction forces in drop landings. To this end a four body-segment wobbling mass model was developed to reproduce the vertical ground reaction force curve for the first 100 ms of landing. Particular attention was paid to the passive impact phase, while selecting most model parameters a priori, thus permitting examination of the rigid body assumption on system kinetics. A two-dimensional wobbling mass model was developed in DADS (version 9.00, CADSI) to simulate landing from a drop of 43 cm. Subject-specific inertia parameters were calculated for both the rigid links and the wobbling masses. The magnitude and frequency response of the soft tissue of the subject to impulsive loading was measured and used as a criterion for assessing the wobbling mass motion. The model successfully reproduced the vertical ground reaction force for the first 100 ms of the landing with a peak vertical ground reaction force error of 1.2% and root mean square errors of 5% for the first 15 ms and 12% for the first 40 ms. The resultant joint forces and torques were lower for the wobbling mass model compared with a rigid body model, up to nearly 50% lower, indicating the important contribution of the wobbling masses on reducing system loading.  相似文献   

10.
We measured the peak hand impact force involved in bimanually arresting a forward fall to the ground from a 1-m shoulder height in five healthy young males. The effects of three different subject instruction sets: "arrest the fall naturally"; "keep the head as far from the ground as possible"; and "minimize the peak hand forces" were studied by measuring body segment kinematics, ground reaction forces, and upper-extremity myoelectric activity. The hypotheses were tested that the (a) arrest strategy did not influence peak impact force, (b) arm configuration, impact velocity and upper-extremity electromyography (EMG) levels correlate to the peak impact force (c) and impacting the ground with one hand leading the other does not increase the impact force over that obtained with simultaneous hand use. The results show that these subjects were able to volitionally decrease the peak impact force at the wrist by an average of 27% compared with a "natural landing" (p=0.014) and 40% compared with a "stiff-arm landing" (p<0.0005). The magnitude of the peak unilateral wrist force varied from 0.65 to 1.7 body weight for these moderate falls onto a padded surface. Peak force correlated with the elbow angle at impact, wrist velocity at impact and with pre-EMG triceps activity. The force was not significantly higher for non-simultaneous hand impacts. We conclude that fall arrest strategy can substantially alter the peak impact forces applied to the distal forearm during a fall arrest. Therefore, the fall arrest strategy likely influences wrist injury risk independent of bone strength.  相似文献   

11.
Patellofemoral pain is a disabling, highly prevalent pathology. Altered patellofemoral contact forces are theorized to contribute to this pain. Musculoskeletal modeling has been employed to better understand the etiology of patellofemoral pain. Currently, there are no data on the effective quadriceps moment arm for individuals with patellofemoral pain, forcing researchers to apply normative values when modeling such individuals. In addition, the ratio of patellofemoral reaction force to quadriceps force is often used as a surrogate for patellofemoral joint contact force, ignoring the fact that the quadriceps efficiency can vary with pathology and intervention. Thus, the purposes of this study were to: (1) quantify the effective quadriceps moment arm in individuals with patellofemoral pain and compare this value to a control cohort and (2) develop a novel methodology for quantifying the normalized patellofemoral joint reaction force in vivo during dynamic activities. Dynamic MR data were captured as subjects with patellofemoral pain (30F/3M) cyclically flexed their knee from 10° to 40°. Data for control subjects (29F/9M) were taken from a previous study. The moment arm data acquired across a large cohort of individuals with patellofemoral pain should help advance musculoskeletal modeling. The primary finding of this study was an increased mean normalized patellofemoral reaction force of 14.9% (maximum values at a knee angle of 10°) in individuals with patellofemoral pain. Understanding changes in the normalized patellofemoral reaction force with pathology may lead to improvements in clinical decision making, and consequently treatments, by providing a more direct measure of altered patellofemoral joint forces.  相似文献   

12.
Fall-related wrist fractures are common at any age. We used a seven-link, sagittally symmetric, biomechanical model to test the hypothesis that systematically alterations in the configuration of the body during a forward fall from standing height can significantly influence the impact force on the wrists. Movement of each joint was accomplished by a pair of agonist and antagonist joint muscle torque actuators with assigned torque-angle, torque-velocity, and neuromuscular latency properties. Proportional-derivative joint controllers were used to achieve desired target body segment configurations in the pre- andor postground contact phases of the fall. Outcome measures included wrist impact forces and whole-body kinetic energy at impact in the best, and worst, case impact injury risk scenarios. The results showed that peak wrist impact force ranged from less than 1 kN to more than 2.5 kN, reflecting a fourfold difference in whole-body kinetic energy at impact (from less than 40 J to more than 160 J) over the range of precontact hip and knee joint angles used at impact. A reduction in the whole-body kinetic energy at impact was primarily associated with increasing negative work associated with hip flexion. Altering upper extremity configuration prior to impact significantly reduced the peak wrist impact force by up to 58% (from 919 N to 2212 N). Increased peak wrist impact forces associated greater shoulder flexion and less elbow flexion. Increasing postcontact arm retraction can reduce the peak wrist impact force by 28% (from 1491 N to 1078 N), but postcontact hip and knee rotations had a relatively small effect on the peak wrist impact force (8% reduction; from 1411 N to 1303 N). In summary, the choice of the joint control strategy during a forward fall can significantly affect the risk of wrist injury. The most effective strategy was to increase the negative work during hip flexion in order to dissipate kinetic energy thereby reducing the loss in potential energy prior to first impact. Extended hip or elbow configurations should be avoided in order to reduce forearm impact forces.  相似文献   

13.
Investigations of human foot and ankle biomechanics rely chiefly on cadaver experiments. The application of proper force magnitudes to the cadaver foot and ankle is essential to obtain valid biomechanical data. Data for external ground reaction forces are readily available from human motion analysis. However, determining appropriate forces for extrinsic foot and ankle muscles is more problematic. A common approach is the estimation of forces from muscle physiological cross-sectional areas and electromyographic data. We have developed a novel approach for loading the Achilles and posterior tibialis tendons that does not prescribe predetermined muscle forces. For our loading model, these muscle forces are determined experimentally using independent plantarflexion and inversion angle feedback control. The independent (input) parameters -- calcaneus plantarflexion, calcaneus inversion, ground reaction forces, and peroneus forces -- are specified. The dependent (output) parameters -- Achilles force, posterior tibialis force, joint motion, and spring ligament strain -- are functions of the independent parameters and the kinematics of the foot and ankle. We have investigated the performance of our model for a single, clinically relevant event during the gait cycle. The instantaneous external forces and foot orientation determined from human subjects in a motion analysis laboratory were simulated in vitro using closed-loop feedback control. Compared to muscle force estimates based on physiological cross-sectional area data and EMG activity at 40% of the gait cycle, the posterior tibialis force and Achilles force required when using position feedback control were greater.  相似文献   

14.
Wrist splints are commonly prescribed to limit wrist motion and provide support at night and during inactive periods but are often used in the workplace. In theory, splinting the wrist should reduce wrist extensor muscle activity by stabilizing the joint and reducing the need for co-contraction to maintain posture. Ten healthy volunteers underwent a series of 24 10-s gripping trials with surface electromyography on 6 forearm muscles. Trials were randomized between splinted and nonsplinted conditions with three wrist postures (30 degrees flexion, neutral, and 30 degrees extension) and four grip efforts. Custom-made Plexiglas splints were taped to the dorsum of the hand and wrist. It was found that when simply holding the dynamometer, use of a splint led to a small (<1% MVE) but significant reduction in activity for all flexor muscles and extensor carpi radialis (all activity <4% maximum). At maximal grip, extensor muscle activity was significantly increased with the splints by 7.9-23.9% MVE. These data indicate that splinting at low-to-moderate grip forces may act to support the wrist against external loading, but appears counterproductive when exerting maximal forces. Wrist bracing should be limited to periods of no to light activity and avoided during tasks that require heavy efforts.  相似文献   

15.
A novel computational model of the wrist that predicts carpal bone motion was developed in order to investigate the complex kinematics of the human wrist.This rigid body spring model (RBSM) of the wrist was built using surface models of the eight carpal bones, the bases of the five metacarpal bones, and the distal parts of the ulna and radius, all obtained from computed tomography (CT) scans of a cadaver upper limb. Elastic contact conditions between the rigid bodies modeled the influence of the cartilage layers, and ligamentous structures were constructed using nonlinear, tension-only spring elements. Motion of the wrist was simulated by applying forces to the tendons of the five main wrist muscles modeled.Three wrist motions were simulated: extension, ulnar deviation and radial deviation. The model was tested and tuned by comparing the simulated displacement and orientation of the carpal bones with previously obtained CT-scans of the same cadaver arm in deviated (45°ulnar and 15°radial), and extended (57°) wrist positions. Simulation results for the scaphoid, lunate, capitate, hamate and triquetrum are presented here and provide credible prediction of carpal bone movement. These are the first reported results of such a model. They indicate promise that this model will assist in future wrist kinematics investigations. However, further optimization and validation are required to define and guarantee the validity of results.  相似文献   

16.
Computational models of musculoskeletal joints and limbs can provide useful information about joint mechanics. Validated models can be used as predictive devices for understanding joint function and serve as clinical tools for predicting the outcome of surgical procedures. A new computational modeling approach was developed for simulating joint kinematics that are dictated by bone/joint anatomy, ligamentous constraints, and applied loading. Three-dimensional computational models of the lower leg were created to illustrate the application of this new approach. Model development began with generating three-dimensional surfaces of each bone from CT images and then importing into the three-dimensional solid modeling software SOLIDWORKS and motion simulation package COSMOSMOTION. Through SOLIDWORKS and COSMOSMOTION, each bone surface file was filled to create a solid object and positioned necessary components added, and simulations executed. Three-dimensional contacts were added to inhibit intersection of the bones during motion. Ligaments were represented as linear springs. Model predictions were then validated by comparison to two different cadaver studies, syndesmotic injury and repair and ankle inversion following ligament transection. The syndesmotic injury model was able to predict tibial rotation, fibular rotation, and anterior/posterior displacement. In the inversion simulation, calcaneofibular ligament extension and angles of inversion compared well. Some experimental data proved harder to simulate accurately, due to certain software limitations and lack of complete experimental data. Other parameters that could not be easily obtained experimentally can be predicted and analyzed by the computational simulations. In the syndesmotic injury study, the force generated in the tibionavicular and calcaneofibular ligaments reduced with the insertion of the staple, indicating how this repair technique changes joint function. After transection of the calcaneofibular ligament in the inversion stability study, a major increase in force was seen in several of the ligaments on the lateral aspect of the foot and ankle, indicating the recruitment of other structures to permit function after injury. Overall, the computational models were able to predict joint kinematics of the lower leg with particular focus on the ankle complex. This same approach can be taken to create models of other limb segments such as the elbow and wrist. Additional parameters can be calculated in the models that are not easily obtained experimentally such as ligament forces, force transmission across joints, and three-dimensional movement of all bones. Muscle activation can be incorporated in the model through the action of applied forces within the software for future studies.  相似文献   

17.
Investigations of in vivo joint mechanics are important for understanding the joint function under functional loading and the mechanisms of pathology. In this study we used magnetic resonance imaging (MRI) based joint contact modeling to evaluate in vivo joint contact mechanics in the human wrist. MRI scans were performed on the wrists of four subjects while they maintained light grasp of a cylinder, and with the same wrist relaxed. 3D models of the radius, scaphoid and lunate, including cartilage surface data, were constructed from the relaxed image data. These models were transformed into the loaded configuration, as determined from the grasp image data, and contact mechanics were evaluated. The resulting contact pressures, areas and forces were then analyzed for each articulation and for each subject. Contact areas were measured directly from grasp MRI images for comparison to the model predictions. The first-ever estimates for in vivo radioscaphoid and radiolunate contact pressure agreed reasonably well with previous cadaveric studies. This investigation also produced novel in vivo scapholunate contact results that were similar to radiolunate data. The specimen-specific contact area comparison generally showed substantial variability between the models and the direct measurements from MRI. On average, the models were within about 10% of the direct MRI measurements for radioscaphoid and scapholunate contact areas, but radiolunate contact areas from the model were only within 55% of the direct measurements. Overall, the results of the study suggest that MRI-based modeling has substantial potential for evaluation of in vivo joint contact mechanics, especially as technology and methodology improve.  相似文献   

18.
We compared predicted passive finger joint torques from a biomechanical model that includes the exponential passive muscle force–length relationship documented in the literature with finger joint torques estimated from measures in ten adult volunteers. The estimated finger joint torques were calculated from measured right index fingertip force, joint postures, and anthropometry across 18 finger and wrist postures with the forearm muscles relaxed. The biomechanical model predicting passive finger joint torques included three extrinsic and three intrinsic finger muscles. The values for the predicted passive joint torques were much larger than the values calculated from the fingertip force and posture measures with an average RMS error of 7.6 N cm. Sensitivity analysis indicated that the predicted joint torques were most sensitive to passive force–length model parameters compared to anthropometric and postural parameters. Using Monte Carlo simulation, we determined a new set of values for the passive force–length model parameters that reduced the differences between the joint torques calculated from the two methods to an average RMS value of 0.5 N cm, a 94% average improvement of error from the torques predicted using the existing data. These new parameter values did vary across individuals; however, using an average set for the parameter values across subjects still reduced the average RMS difference to 0.8 N cm. These new parameters may improve dynamic modeling of the finger during sub-maximal force activities and are based on in vivo data rather than traditional in vitro data.  相似文献   

19.
We aimed to determine the role of the wrist, elbow and shoulder joints to single-finger tapping. Six human subjects tapped with their index finger at a rate of 3 taps/s on a keyswitch across five conditions, one freestyle (FS) and four instructed tapping strategies. The four instructed conditions were to tap on a keyswitch using the finger joint only (FO), the wrist joint only (WO), the elbow joint only (EO), and the shoulder joint only (SO). A single-axis force plate measured the fingertip force. An infra-red active-marker three-dimensional motion analysis system measured the movement of the fingertip, hand, forearm, upper arm and trunk. Inverse dynamics estimated joint torques for the metacarpal-phalangeal (MCP), wrist, elbow, and shoulder joints. For FS tapping 27%, 56%, and 18% of the vertical fingertip movement were a result of flexion of the MCP joint and wrist joint and extension of the elbow joint, respectively. During the FS movements the net joint powers between the MCP, wrist and elbow were positively correlated (correlation coefficients between 0.46 and 0.76) suggesting synergistic efforts. For the instructed tapping strategies (FO, WO, EO, and SO), correlations decreased to values below 0.35 suggesting relatively independent control of the different joints. For FS tapping, the kinematic and kinetic data indicate that the wrist and elbow contribute significantly, working in synergy with the finger joints to create the fingertip tapping task.  相似文献   

20.
In this paper, a calibration method to compensate for changes in SEMG amplitude with joint angle is introduced. Calibration factors were derived from constant amplitude surface electromyogram (SEMG) recordings from the biceps brachii (during elbow flexion) and the triceps brachii (during elbow extension) across seven elbow joint angles. SEMG data were then recorded from the elbow flexors (biceps brachii and brachioradialis) and extensors (triceps brachii) during isometric, constant force flexion and extension contractions at the same joint angles. The resulting force at the wrist was measured. The fast orthogonal search method was used to find a mapping between the system inputs – estimated SEMG amplitudes and joint angle – and the system output – measured force, for both calibrated and non-calibrated SEMG data. Models developed with calibrated data yielded a statistically significant improvement in force estimation compared to models developed with non-calibrated data, suggesting that the calibration method can compensate for changes in the SEMG–force relationship with changing joint angle. It was also found that the number of non-linear, joint angle-dependent terms used in the SEMG–force model was reduced with calibration. Additionally, initial inter-session analysis performed for four subjects suggests that calibration values can be used for subsequent recording sessions, and different output force levels.  相似文献   