首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 84 毫秒
1.
2.
Multiplex RT-PCR assays have been widely used tools for detection and differentiation of a panel of respiratory viral pathogens. In this study, we evaluated the Qiagen ResPlex II V2.0 kit and explored factors influencing its sensitivity. Nasopharyngeal swab (NPS) specimens were prospectively collected from pediatric inpatients with lower respiratory tract infections at the time of admission in the Shenzhen Children’s Hospital from May 2009 to April 2010. Total nucleic acids were extracted using the EZ1 system (Qiagen, Germany) and 17 respiratory viruses and genotypes including influenza A virus (FluA), FluB, parainfluenza virus 1 (PIV1), PIV2, PIV3, PIV4, respiratory syncytial virus (RSV), human metapneumovirus (hMPV), rhinoviruses (RhV), enteroviruses (EnV), human bocaviruses (hBoV), adenoviruses (AdV), four coronaviruses (229E, OC43, NL63 and HKU1), and FluA 2009 pandemic H1N1(H1N1-p) were detected and identified by the ResPlex II kit. In parallel, 16 real-time TaqMan quantitative RT-PCR assays were used to quantitatively detect each virus except for RhV. Influenza and parainfluenza viral cultures were also performed. Among the total 438 NPS specimens collected during the study period, one or more viral pathogens were detected in 274 (62.6%) and 201(45.9%) specimens by monoplex TaqMan RT-PCR and multiplex ResPlex, respectively. When results from monoplex PCR or cell culture were used as the reference standard, the multiplex PCR possessed specificities of 92.9–100.0%. The sensitivity of multiplex PCR for PIV3, hMPV, PIV1 and BoV were 73.1%, 70%, 66.7% and 55.6%, respectively, while low sensitivities (11.1%–40.0%) were observed for FluA, EnV, OC43, RSV and H1N1. Among the seven viruses/genotypes detected with higher frequencies, multiplex PCR sensitivities were correlated significantly with viral loads determined by the TaqMan RT-PCR in FluA, H1N1-p and RSV (p=0.011?0.000). The Qiagen ResPlex II multiplex RT-PCR kit possesses excellent specificity for simultaneous detection of 17 viral pathogens in NPS specimens in pediatric inpatients at the time of admission. The sensitivity of multiplex RT-PCR was influenced by viral loads, specimen process methods, primer and probe design and amplification condition.  相似文献   

3.
A procedure has been developed for the rapid detection of enteroviruses and adenoviruses in environmental samples. Several systems for virus concentration and extraction of nucleic acid were tested by adding adenovirus type 2 and poliovirus type 1 to different sewage samples. The most promising method for virus recovery involved the concentration of viruses by centrifugation and elution of the virus pellets by treatment with 0.25 N glycine buffer, pH 9.5. Nucleic acid extraction by adsorption of RNA and DNA to silica particles was the most efficient. One aliquot of the extracted nucleic acids was used for a nested two-step PCR, with specific primers for all adenoviruses; and another aliquot was used to synthesize cDNA for a nested two-step PCR with specific primers for further detection of seeded polioviruses or all enteroviruses in the river water and sewage samples. The specificity and sensitivity were evaluated, and 24 different enterovirus strains and the 47 human adenovirus serotypes were recognized by the primers used. The sensitivity was estimated to be between 1 and 10 virus particles for each of the species tested. Twenty-five samples of sewage and polluted river water were analyzed and showed a much higher number of positive isolates by nested PCR than by tissue culture analysis. The PCR-based detection of enteroviruses and adenoviruses shows good results as an indicator of possible viral contamination in environmental wastewater.  相似文献   

4.
5.
6.
AIMS: To evaluate an integrated cell culture (ICC)-multiplex-nested PCR using the buffalo green monkey kidney (BGMK) cells for the simultaneous detection of both enteroviruses and adenoviruses in surface water and tap water samples and optimize the procedure for more sensitive detection of virus showing no apparent cytopathic effect (CPE). METHODS AND RESULTS: A total of 69 surface water and 50 tap water samples were analysed by the ICC-multiplex-nested PCR. All the PCRs were performed five times with a cell lysate from each flask after at least 2 weeks incubation. Forty-six surface water samples (66.7%) and 23 tap water samples (46.0%) exhibited CPE by the cell culture method. By using an ICC-multiplex-nested PCR, 53 surface water samples (76.8%) and 29 tap water samples (58.0%) were determined as containing infectious enteric viral particles. CONCLUSIONS: An ICC-PCR method with a long incubation time using BGMK cells enables the simultaneous detection of enteroviruses and adenoviruses from environmental water samples, including tap water, even with low numbers of viruses. SIGNIFICANCE AND IMPACT OF THE STUDY: A method capable of detecting small numbers of viral particles is necessary.  相似文献   

7.
8.
9.
10.
11.
Recent studies have shown that the fecal indicator bacteria (FIB) currently used to indicate water quality in the coastal environment may be inadequate to reflect human viral contamination. Coliphage was suggested as a better indicator of human viral pollution and was proposed by the U.S. EPA as an alternative indicator for fecal pollution in groundwater. In this study, we investigated the occurrence and distribution of FIB, F+ coliphage, and PCR-detectable human adenovirus and enterovirus for an entire year at 15 locations around the Newport Bay watershed, an important southern California estuary for water recreation and an ecological reserve. Peak concentrations and prevalences of FIB and F+ coliphage were associated with winter storms (wet weather). Human adenoviruses and enteroviruses, however, were detected by PCR in approximately 5% of samples collected in the summer (dry weather) but only once in wet weather. These results demonstrated that FIB and coliphage have similar seasonal and freshwater-to-saltwater distribution patterns, while the detection of human viruses depends on a distribution pattern that is the opposite of that of FIB and coliphage. This research suggested that coliphage and FIB share similar environmental sources, while sources of human viruses in Newport Bay are perhaps different.  相似文献   

12.
13.
Recent studies have shown that the fecal indicator bacteria (FIB) currently used to indicate water quality in the coastal environment may be inadequate to reflect human viral contamination. Coliphage was suggested as a better indicator of human viral pollution and was proposed by the U.S. EPA as an alternative indicator for fecal pollution in groundwater. In this study, we investigated the occurrence and distribution of FIB, F+ coliphage, and PCR-detectable human adenovirus and enterovirus for an entire year at 15 locations around the Newport Bay watershed, an important southern California estuary for water recreation and an ecological reserve. Peak concentrations and prevalences of FIB and F+ coliphage were associated with winter storms (wet weather). Human adenoviruses and enteroviruses, however, were detected by PCR in ~5% of samples collected in the summer (dry weather) but only once in wet weather. These results demonstrated that FIB and coliphage have similar seasonal and freshwater-to-saltwater distribution patterns, while the detection of human viruses depends on a distribution pattern that is the opposite of that of FIB and coliphage. This research suggested that coliphage and FIB share similar environmental sources, while sources of human viruses in Newport Bay are perhaps different.  相似文献   

14.
15.
Standard methods for the detection of enteroviruses in environmental samples involve the use of cell culture, which is expensive and time-consuming. The polymerase chain reaction (PCR) is an attractive method for the detection of enteroviruses in water because primary cell culture is not needed and the increased sensitivity of PCR allows detection of the low numbers of target DNAs and RNAs usually found in environmental samples. However, environmental samples often contain substances that inhibit PCR amplification of target DNA and RNA. Procedures that remove substances that interfere with the amplification process need to be developed if PCR is to be successfully applied to environmental samples. An RNA-PCR assay for the detection of enteroviruses in water was developed and used to test a variety of groundwater concentrates and humic acid solutions seeded with poliovirus type 1. The groundwater samples and humic acid solutions were treated with Sephadex G-50, Sephadex G-100, Sephadex G-200, Chelex-100 resin, and a mixed bed resin to remove PCR-inhibitory material from the samples. Sephadex G-100 in combination with Chelex-100 was found to be very effective in removing inhibitory factors for the detection of enteroviruses in groundwater concentrates by PCR. Viruses were detected in two of the groundwater concentrates by the RNA-PCR assay after treatment with Sephadex G-100 plus Chelex-100. This was confirmed by tissue culture, suggesting that the treatment protocol and, subsequently, the RNA-PCR assay are applicable for the detection of enteroviruses in environmental samples.  相似文献   

16.
Aims: To study the virological quality of surface water from highly urbanized tropical water catchment areas and to determine predominant enteric viral genotypes in surface water. Methods and Results: A wide range of human pathogenic viruses in urban surface waters was screened by nested PCR assays after concentration by ultrafiltration. Among the 84 water samples collected, at least one virus was detected in 70 (83·3%) of these samples. Noroviruses were determined to be the most prevalent enteric viruses detected in urban surface water samples, followed by astroviruses, enteroviruses, adenoviruses and hepatitis A viruses. The molecular characterization of environmental viral isolates suggested co‐circulation of multiple genotypes of both noroviruses GI and GII, astroviruses and enteroviruses in urban surface waters. Conclusions: Human enteric viruses with great genetic diversity were detected in surface waters, indicating the presence of human origin of faecal contamination in highly urbanized water catchment areas. Significance and Impact of the Study: The present study identifies and characterizes potential viral hazards of source waters for drinking water supply and recreational activities. This will enable scientific decisions to be made regarding the selection and prioritization of human pathogenic viruses to be included in the future risk assessment and treatment evaluation for water and wastewater.  相似文献   

17.
18.
Pathogenic bacteria and enteric viruses can be introduced into the environment via human waste discharge. Methods for rapid detection and quantification of human viruses and fecal indicator bacteria in water are urgently needed to prevent human exposure to pathogens through drinking and recreational waters. Here we describe the development of two real-time PCR methods to detect and quantify human adenoviruses and enterococci in environmental waters. For real-time quantification of enterococci, a set of primers and a probe targeting the 23S rRNA gene were used. The standard curve generated using Enterococcus faecalis genomic DNA was linear over a 7-log-dilution series. Serial dilutions of E. faecalis suspensions resulted in a lower limit of detection (LLD) of 5 CFU/reaction. To develop real-time PCR for adenoviruses, degenerate primers and a Taqman probe targeting a 163-bp region of the adenovirus hexon gene were designed to specifically amplify 14 different serotypes of human adenoviruses, including enteric adenovirus serotype 40 and 41. The standard curve generated was linear over a 5-log-dilution series, and the LLD was 100 PFU/reaction using serial dilutions of purified adenoviral particles of serotype 40. Both methods were optimized to be applicable to environmental samples. The real-time PCR methods showed a greater sensitivity in detection of adenoviruses in sewage samples than the viral plaque assay and in detection of enterococci in coastal waters than the bacterial culture method. However, enterococcus real-time PCR overestimated the number of bacteria in chlorinated sewage in comparison with the bacterial culture method. Overall, the ability via real-time PCR to detect enterococci and adenoviruses rapidly and quantitatively in the various environmental samples represents a considerable advancement and a great potential for environmental applications.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号