 共查询到20条相似文献,搜索用时 968 毫秒
1.
Micromotions at the interface between bone and prosthesis are believed to induce bone resorption and ultimately lead to loosening of the implant. Thus the initial stability achieved by a hip prosthesis is an important factor for the long-term function of the implant. Knowing the biological consequences of the mechanical conditions, it appears to be mandatory to measure the extent of these three-dimensional movements. An in vitro dynamic method for measurement of the micromotion of the femoral component of hip prostheses has been developed. Tests in cemented prostheses have confirmed that the use of cement reduces sinkage and rotation manyfold and have yielded reference values for stability. Comparison with two types of cementless prostheses has shown that certain cementless implants may achieve stability comparable to cemented ones in some load directions.  相似文献   

2.
The interfacial micromotion is closely associated to the long-term success of cementless hip prostheses. Various techniques have been proposed to measure them, but only a few number of points over the stem surface can be measured simultaneously. In this paper, we propose a new technique based on micro-Computer Tomography (μCT) to measure locally the relative interfacial micromotions between the metallic stem and the surrounding femoral bone. Tantalum beads were stuck at the stem surface and spread at the endosteal surface. Relative micromotions between the stem and the endosteal bone surfaces were measured at different loading amplitudes. The estimated error was 10 μm and the maximal micromotion was 60 μm, in the loading direction, at 1400 N. This pilot study provided a local measurement of the micromotions in the 3 direction and at 8 locations on the stem surface simultaneously. This technique could be easily extended to higher loads and a much larger number of points, covering the entire stem surface and providing a quasi-continuous distribution of the 3D interfacial micromotions around the stem. The new measurement method would be very useful to compare the induced micromotions of different stem designs and to optimize the primary stability of cementless total hip arthroplasty.  相似文献   

3.
A lack of initial stability of the fixation is associated with aseptic loosening of the tibial components of cementless knee prostheses. With sufficient stability after surgery, minimal relative motion between the prosthesis and bone interfaces allows osseointegation to occur thereby providing a strong prosthesis-to-bone biological attachment. Finite element modelling was used to investigate the bone–prosthesis interface micromotion and the relative risk of aseptic loosening. It was anticipated that by prescribing different joint loads representing gait and other activities, and the consideration of varying tibial–femoral contact points during knee flexion, it would influence the computational prediction of the interface micromotion. In this study, three-dimensional finite element models were set up with applied loads representing walking and stair climbing, and the relative micromotions were predicted. These results were correlated to in-vitro measurements and to the results of prior retrieval studies. Two load conditions, (i) a generic vertical joint load of 3×body weight with 70%/30% M/L load share and antero-posterior/medial-lateral shear forces, acted at the centres of the medial and lateral compartments of the tibial tray, and (ii) a peak vertical joint load at 25% of the stair climbing cycle with corresponding antero-posterior shear force applied at the tibial–femoral contact points of the specific knee flexion angle, were found to generate interface micromotion responses which corresponded to in-vivo observations. The study also found that different loads altered the interface micromotion predicted, so caution is needed when comparing the fixation performance of various reported cementless tibial prosthetic designs if each design was evaluated with a different loading condition.  相似文献   

4.
A new experimental technique for measuring generalized three-dimensional motion of vertebral bodies during cyclic loading in vitro is presented. The system consists of an orthogonal array of three lasers mounted rigidly to one vertebra, and a set of three mutually orthogonal charge-coupled devices mounted rigidly to an adjacent vertebra. Each laser strikes a corresponding charge-coupled device screen. The mathematical model of the system is reduced to a linear set of equations with consequent matrix algebra allowing fast real-time data reduction during cyclic movements of the spine. The range and accuracy of the system is well suited for studying thoracolumbar motion segments. Distinct advantages of the system include miniaturization of the components, the elimination of the need for mechanical linkages between the bodies, and a high degree of accuracy which is not dependent on viewing volume as found in photogrammetric systems. More generally, the spectrum of potential applications of systems of this type to the real-time measurement of the relative motion of two bodies is extremely broad.  相似文献   

5.
Existing standards for the preclinical testing of femoral hip implants have been successful in the objective of guaranteeing the implant's fatigue strength. There is a need for an experimental test which could ensure prostheses were not susceptible to aseptic loosening. In this study we measure the relative movement between the prosthesis and the bone of four different cemented femoral component designs in in vitro tests. The aim is to determine if differences can be distinguished and whether the differences correlate with clinical performance. The four designs are the Charnley (DePuy International Ltd., UK), the Exeter (Stryker Osteonics Howmedica Corp., USA), the Lubinus SPII (Waldemar-Link GmbH, Germany), and the Miiller Curved (JRI Ltd, UK). Five tests were carried out for each femoral component type, giving a total of 20 tests, and their permanent relative displacement (termed migration) and recoverable (i.e., elastic) relative displacement (termed inducible displacement) monitored over one million loading cycles. Considerable variation occurred in the tests. Nonetheless, most femoral components migrated medially, posteriorly, and distally. Most also rotated into varus. Translations of the Charnley (64 microns) and Lubinus (67 microns) implants were less than the Müller (72 microns) and Exeter (94 microns) implants, but this difference is not statistically significant. Most of the femoral components had rapid early migration followed by slower steady-state migration. With regard to the steady state inducible displacements of the prostheses, those of the Charnley, Exeter, and Lubinus decreased or were stable with respect to time, whilst those of the Müller typically increased with respect to time. It is concluded that migration is not a suitable basis for in vitro comparison of prosthesis designs. However inducible displacement trends provide a clinically comparable performance ranking.  相似文献   

6.
A new experimental technique for measuring generalized three-dimensional motion of vertebral bodies during cyclic loading in vitro is presented. The system consists of an orthogonal array of three lasers mounted rigidly to one vertebra, and a set of three mutually orthogonal charge-coupled devices mounted rigidly to an adjacent vertebra. Each laser strikes a corresponding charge-coupled device screen. The mathematical model of the system is reduced to a linear set of equations with consequent matrix algebra allowing fast real-time data reduction during cyclic movements of the spine. The range and accuracy of the system is well suited for studying thoracolumbar motion segments. Distinct advantages of the system include miniaturization of the components, the elimination of the need for mechanical linkages between the bodies, and a high degree of accuracy which is not dependent on viewing volume as found in photogrammetric systems. More generally, the spectrum of potential applications of systems of this type to the real-time measurement of the relative motion of two bodies is extremely broad.  相似文献   

7.
In this work we tackled the problem of accurate measurement of internal-external (IE) rotations in the prosthetic knee. We presented a magnetic measurement system to be implanted in the knee prostheses in order to measure IE without soft tissue artifacts. The measurement system consisted of a permanent magnet attached under the tibial plate of the prosthesis and a combination of magnetic sensors in the polyethylene insert. Two different sensor configurations were designed, and five different angle estimators for measurement of IE angles were defined and tested based on several static and dynamic measurements toward a stereophotogrammetry motion capture system. Also a noise analysis was done to see which estimators are less sensitive to measurement noise. One-sensor configuration provided lower power budget with dynamic RMS error of 0.49° and a noise range of ±0.53°. Two-sensor configuration doubles the power consumption but provided slightly lower dynamic RMS error (0.37°) and a noise range of ±0.42°, and offers the possibility of having redundancy in case of damaged sensor.  相似文献   

8.
All hip replacement prostheses alter the load transfer from the hip joint into the femur by changing the mechanical loading of the proximal femur from an externally to an internally loaded system. This alteration of the load transfer causes stress shielding and might lead to severe bone loss, especially with uncemented prostheses. To minimize these effects, load transfer to the femur should occur as proximal as possible. In order to support sufficient primary stability, however, directly post operative (PO) distal stabilization is reasonable. Consequently, the prostheses have to alter its mechanical characteristics after implantation. This concept is referred to as load-shift concept. Primary stability during the early PO state is provided by a prosthesis shaft, which is widened at the tip by a biodegradable pin. After resorption of the pin load transfer occurs no longer distally. The objective of this study was the numerical evaluation of the load-shift concept. The analysis was performed with a finite element model. Three-dimensional non-linear dynamic gait analyses data were used to evaluate whether the load transfer during walking can be altered effectively by insertion and resorption of a distal pin. Directly PO 38% of the transverse load is transferred through the prosthesis shaft and micromotion of the proximal prostheses tip is below 55 microm. After resorption of the pin, no transverse loads are transferred through the prosthesis shaft. Therefore, the loading of the proximal bone tissue is far more pronounced than in the case of a standard prosthesis, demonstrating the feasibility of the load-shift concept. A balanced degradation of the pin simultaneously with the ingrowth of the prosthesis is expected to reduce hip replacement complications.  相似文献   

9.
In vitro pre-clinical tests of hip prostheses have not yet been developed to the extent that inferior prostheses can be 'screened-out' prior to animal or clinical trials. This paper reports the experimental part of a project to develop a pre-clinical testing platform for cemented femoral hip implants. It is based on the clinical observation (K?rrholm et al. JBJS, 76B (1994) 912-916) that higher subsidence (distal migration) correlates with early revision of hip prostheses. A protocol to measure the relative movement between implant and bone was designed to test whether or not such a measurement, if made in a laboratory, could discriminate between hip prostheses. The protocol was applied to the Lubinus SPII prosthesis (W. Link, Germany) and a Müller Curved Stem (JRI Ltd., UK)-these prostheses were chosen because they are known to have different loosening rates in vivo. Five prostheses of each design were tested. The migration, the rate-of-migration, and the inducible displacement of each prosthesis was recorded over two million cycles of loading.For each implant, rapid initial migration was found, followed by a period of steady-state migration. In the majority of cases, the prostheses migrated medially, distally and posteriorly. On average, the Lubinus migrated less than the Müller in all directions. The average Lubinus migration was less than half that of the Müller, and this difference was significant at a level of p=0.05. Inducible displacement was greater for the Müller compared to the Lubinus. Furthermore, the inducible displacement decreased over time for the majority of Lubinus prostheses whereas it increased over time for the majority of the Müller prostheses leading to the conclusion that a rapid pre-clinical test based on measurement of inducible displacement may be possible.  相似文献   

10.
目的:通过三维有限元分析方法来观察并比较3种不同弹性模量钛合金股骨假体在羊股骨置换模型中von-Mises应力分布的情况。方法:采用64排螺旋CT对一健康成年羊的下肢股骨进行全长的CT扫描,扫描层厚为0.5 mm,扫描所得的数据存储为DICOM文件。将得到的DICOM文件导入到CT图像分析软件Mimics 10.0,然后利用Mimics 10.0软件来生成股骨的骨质点云数据,再将生成的骨质点云数据导入到Simpleware分析软件,通过机械加工反求中的复杂曲面造型技术建立起精确的三维实体模型。对三维实体模型进行网格划分,确定了髓腔的形状,并根据羊下肢股骨髓腔的形状设计了作者实验用的羊股骨假体模型,然后在ANSYS 12.1软件中进行网格划分。给予加载缓慢行走载荷以及扭转载荷,分析并比较羊股骨以及3种不同弹性模量钛合金股骨假体在股骨置换模型中von-Mises应力分布的情况。结果:在缓慢行走载荷以及扭转载荷条件下,3种不同弹性模量钛合金股骨假体von-Mises应力分布变化趋势一致,假体的柄颈结合部以及假体柄上1/3为应力集中区域。3种不同弹性模量的最大应力集中点均位于柄颈结合部,60 GPa弹性模量的股骨假体植入后假体的最大应力最小(37.8 MPa、29.1 MPa),股骨的最大应力最大(12.6 MPa、24.5 MPa);80 GPa的次之,假体的最大应力(38.4 MPa、33.4 MPa),股骨的最大应力(12.5 MPa、24.5 MPa);110 GPa的股骨假体植入后假体的最大应力最大(38.9 MPa、38.1 MPa),股骨的最大应力最小(12.3 MPa、24.5 MPa)。60 GPa弹性模量的股骨假体植入后的假体最大位移和相对位移均最小(缓慢行走载荷下假体最大位移为0.551 mm、相对位移为0.008 mm,扭转载荷下假体最大位移为0.730 mm、相对位移为0.011 mm)。结论:较低弹性模量的钛合金股骨假体(60 GPa)由于其弹性模量更接近于骨组织的弹性模量,股骨假体与股骨间的"应力遮挡"效应较小,更有利于应力在股骨假体及股骨间的传递,增加了股骨假体的早期稳定性,延长了其临床寿命。  相似文献   

11.
The initial stability of cementless femoral components is crucial for the long-term success of total hip arthroplasty. This has been reported in animal and clinical studies. Until now, the stability was evaluated by the measurement of relative micromotion on a few simultaneous locations around the stem in cadaveric experiments. This paper presents an extended experimental setup to measure simultaneously local micromotion, subsidence and gap on hundreds of points at the bone-stem interface. This technique we applied to anatomical and straight stems in three pairs of cadaveric femurs. Measurements were in agreement with typically reported values. Conversely to other methods, which measure micromotion between implant and bone anchoring points of the measuring device, our method provides local micromotion between stem surface and adjacent bone surface. The observed variation of micromotion at the peri-implant surface confirms the importance of this simultaneous measure on a lot of points around the implant.  相似文献   

12.
A new technique is described that reduces error due to skin movement artifact in the opto-electronic measurement of in vivo skeletal motion. This work builds on a previously described point cluster technique marker set and estimation algorithm by extending the transformation equations to the general deformation case using a set of activity-dependent deformation models. Skin deformation during activities of daily living are modeled as consisting of a functional form defined over the observation interval (the deformation model) plus additive noise (modeling error). The method is described as an interval deformation technique. The method was tested using simulation trials with systematic and random components of deformation error introduced into marker position vectors. The technique was found to substantially outperform methods that require rigid-body assumptions. The method was tested in vivo on a patient fitted with an external fixation device (Ilizarov). Simultaneous measurements from markers placed on the Ilizarov device (fixed to bone) were compared to measurements derived from skin-based markers. The interval deformation technique reduced the errors in limb segment pose estimate by 33 and 25% compared to the classic rigid-body technique for position and orientation, respectively. This newly developed method has demonstrated that by accounting for the changing shape of the limb segment, a substantial improvement in the estimates of in vivo skeletal movement can be achieved.  相似文献   

13.
Screw displacement axes (SDAs) have been employed to describe joint kinematics in biomechanical studies. Previous reports have investigated the accuracy of SDAs combining various motion analysis techniques and smoothing procedures. To our knowledge, no study has assessed SDA accuracy describing the relative movement between adjacent bodies with an electromagnetic tracking system. This is important, since in relative motion, neither body is fixed and consequently sensitivity to potential measurement errors from both bodies may be significant. Therefore, this study assessed the accuracy of SDAs for describing relative motion between two moving bodies. We analyzed numerical simulated data, and physical experimental data recorded using a precision jig and electromagnetic tracking device. The numerical simulations demonstrated SDA position accuracy (p=0.04) was superior for single compared to relative body motion, whereas orientation accuracy (p=0.2) was similar. Experimental data showed data-filtering (Butterworth filter) improved SDA position and orientation accuracies for rotation magnitudes smaller or equal to 5.0 degrees, with no effect at larger rotation magnitudes (p<0.05). This suggests that in absence of a filter, SDAs should only be calculated at rotations of greater than 5.0 degrees. For rotation magnitudes of 0.5 degrees (5.0 degrees ) about the SDA, SDA position and orientation error measurements determined from filtered experimental data were 3.75+/-0.30 mm (3.31+/-0.21 mm), and 1.10+/-0.04 degrees (1.04+/-0.03 degrees ), respectively. Experimental accuracy values describing the translation along and rotation about the SDA, were 0.06+/-0.00 mm and 0.09+/-0.01 degrees, respectively. These small errors establish the capability of SDAs to detect small translations, and rotations. In conclusion, application of SDAs should be a useful tool for describing relative motion in joint kinematic studies.  相似文献   

14.
In recent years, elastic network models (ENM) have been widely used to describe low-frequency collective motions in proteins. These models are often validated and calibrated by fitting mean-square atomic displacements estimated from x-ray crystallography (B-factors). We show that a proper calibration procedure must account for the rigid-body motion and constraints imposed by the crystalline environment on the protein. These fundamental aspects of protein dynamics in crystals are often ignored in currently used ENMs, leading to potentially erroneous network parameters. Here we develop an ENM that properly takes the rigid-body motion and crystalline constraints into account. Its application to the crystallographic B-factors reveals that they are dominated by rigid-body motion and thus are poorly suited for the calibration of models for internal protein dynamics. Furthermore, the translation libration screw (TLS) model that treats proteins as rigid bodies is considerably more successful in interpreting the experimental B-factors than ENMs. This conclusion is reached on the basis of a comparative study of various models of protein dynamics. To evaluate their performance, we used a data set of 330 protein structures that combined the sets previously used in the literature to test and validate different models. We further propose an extended TLS model that treats the bulk of the protein as a rigid body while allowing for flexibility of chain ends. This model outperforms other simple models of protein dynamics in interpreting the crystallographic B-factors.  相似文献   

15.
16.
doi: 10.1111/j.1741‐2358.2011.00621.x Unnoticed swallowing of a unilateral removable partial denture Objective: This paper presents a case report about an unnoticed swallowing of a partial denture impacted in the esophagus in a 74‐year old man without serious complications. Background data: Dental prostheses (removable/fixed dental prostheses or fragments of dentures) appear to constitute a significant proportion of swallowed of impacted foreign bodies in the orolaryngopharynx. Conclusion: This case emphazises that is advisable to contraindicate this type of unilateral removable partial denture to replace teeth as temporary or definitive dental prosthesis.  相似文献   

17.
Soft tissue artefact (STA) and marker placement variability are sources of error when measuring the intrinsic kinematics of the foot. This study aims to demonstrate a non-invasive, combined ultrasound and motion capture (US/MC) technique to directly measure foot skeletal motion. The novel approach is compared to a standard motion capture protocol. Fourteen participants underwent instrumented barefoot analysis of foot motion during gait. Markers were attached to foot allowing medial longitudinal arch angle and navicular height to be determined. For the US/MC technique, the navicular marker was replaced by an ultrasound transducer which was secured to the foot allowing the skeletal landmark to be imaged. Ultrasound cineloops showing the location of the navicular tuberosity during the walking trials were synchronised with motion capture measurements and markers mounted on the probe allowed the true position of the bony landmark to be determined throughout stance phase. Two discrete variables, minimum navicular height and maximum MLA angle, were compared between the standard and US/MC protocols. Significant differences between minimum navicular height (P=0.004, 95% CI (1.57, 6.54)) and maximum medial longitudinal arch angle (P=0.0034, 95% CI (13.8, 3.4)) were found between the measurement methods. The individual effects of STA and marker placement error were also assessed. US/MC is a non-invasive technique which may help to provide more accurate measurements of intrinsic foot kinematics.  相似文献   

18.
Kinematic analysis for in vivo assessment of elbow endoprostheses requires knowledge of the exact positions of motion axes relative to bony landmarks or the prosthesis. A prosthesis-based reference system is required for comparison between individuals and studies. The primary aim of this study was to further develop an earlier described algorithm for fusion of radiostereometric analysis (RSA) data and data obtained in 3D computed tomography (CT) for application to the elbow after total joint replacement. The secondary aim was to propose a method for marking of prostheses in 3D CT, enabling definition of a prosthesis-based reference system. Six patients with elbow endoprostheses were investigated.The fusion of data made it possible to visualize the motion axes in relation to the prostheses in the 3D CT volume. The differences between two repeated positioning repetitions of the longitudinal prosthesis axis were less than 0.6° in the frontal and sagittal planes. Corresponding values for the transverse axis were less than 0.6° in the frontal and less than 1.4° (in four out of six less than 0.6°) in the horizontal plane.This study shows that by fusion of CT and RSA data it is possible to determine the accurate position of the flexion axes of the elbow joint after total joint replacement in vivo. The proposed method for implant marking and registration of reference axes enables comparison of prosthesis function between patients and studies.  相似文献   

19.
Uncemented femoral total hip components rely entirely on contact with the prepared femur for their initial fixation. The contact areas and stresses between a straight tubular bone and a metal cylindrical prosthesis 12.5 cm long and 13 mm in diameter were calculated in a finite element model which includes uniform diametral gaps varying from 20 to 500 microns, using transverse loads from 100 to 2000 N. Frictionless three-dimensional contact elements were used between the bone and the prosthesis. Contact stresses were high and irregular in all cases, and the contact areas were small. Two regions of contact were apparent for lower loads and larger gaps. A third region of contact occurred near the distal tip of the implant at higher loads. This region of contact markedly increased the contact stresses at the distal tip of the prosthesis. A 20 microns overlap between bone and implant was modelled to assess a slight interference fit. The contact stress distribution in this case was markedly different from the stress distribution with a 20 microns diametral gap. The data collectively indicates that gaps of less than 20 microns between bone and implant can substantially change contact stress distributions.  相似文献   

20.
Characterisation of hip joint contact forces is essential for the definition of hip joint prosthesis design requirements. In vivo hip joint contact force measurements have been made using instrumented hip joint prostheses. However, to allow determination of the range of values of joint contact force and their directions relative to anatomical structures in a range of subject groups sufficient to form an agreed data base it is necessary to adopt a different approach without the use of an implanted transducer. The use of mathematical models of the lower limb to examine the forces in soft tissues and at the joints has provided valuable insight into internal loading conditions. Several authors have proposed mathematical musculo-skeletal models. However, there have been only limited attempts at validation of these models. It is possible to use the results of in vivo force measurements from instrumented prostheses to validate the results calculated using the mathematical models. In this study two subjects with instrumented hip joint prostheses were studied. Forces at the hip joints were calculated using a three-dimensional model of the leg. Walking at slow, normal and fast speeds (0.97-2.01m/s), weight transfer from two to one leg and back again, and sit to stand were studied. Direct comparisons were made between the 'gold standard' measured hip joint contact forces and the calculated forces. There was general agreement between the calculated and measured forces in both pattern and magnitude. There were, however, discrepancies. Reasons for these differences in results are discussed and possible model developments suggested.  相似文献   