首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
The measurement of intracellular calcium response transients in living mammalian cells is a popular functional assay for identification of agonists and antagonists to receptors or channels of pharmacological interest. In recent years, advances in fluorescence-based detection techniques and automation technologies have facilitated the adaptation of this assay to 384-well microplate format high-throughput screening (HTS) assays. However, the cost and time required performing the intracellular calcium HTS assays in the 384-well format can be prohibitive for HTS campaigns of greater than 1 x 10(6) wells. For these reasons, it is attractive to miniaturize intracellular calcium functional assays to the 1536-well microplate format, where assay volumes and plate throughput can be decreased by several fold. The focus of the research described in this article is the miniaturization of an intracellular calcium assay to 1536-well plate format. This was accomplished by modifying the hardware and software of a fluorometric imaging plate reader (FLIPR) to enable transfer of nanoliters of test compound directly to a 1536-well assay plate, and measure the resulting calcium response from all 1536 wells simultaneously. An intracellular calcium functional assay against the rat muscarinic acetylcholine receptor subtype 1 (rmAchR1) G-protein coupled receptor (GPCR) was miniaturized and executed on this modified instrument. In experiments measuring the activity of known muscarinic receptor agonists and antagonists, the miniaturized FLIPR assay gave EC(50) and IC(50) values and rank order potency comparable to the 384-well format assays. Calculated Z' factors for the miniaturized agonist and antagonist assays were, respectively, 0.56 +/- 0.21 and 0.53 +/- 0.22, which were slightly higher (Z'(agonist) = 0.55 +/- 0.33) and lower (Z'(antagonist) = 0.70 +/- 0.18) than the corresponding values in the 384-well assays. A mock agonist HTS campaign against the muscarinic receptor in miniaturized format was able to identify all wells spiked with the rmAchR1 agonist carbachol.  相似文献   

2.
Results of a complete survey of the more than 2-million-member Pharmacopeia compound collection in a 1536-well microvolume screening assay format are reported. A complete technology platform, enabling the performance of ultra-high throughput screening in a miniaturized 1536-well assay format, has been assembled and utilized. The platform consists of tools for performing microvolume assays, including assay plates, liquid handlers, optical imagers, and data management software. A fluorogenic screening assay for inhibition of a protease enzyme target was designed and developed using this platform. The assay was used to perform a survey screen of the Pharmacopeia compound collection for active inhibitors of the target enzyme. The results from the survey demonstrate the successful implementation of the ultra-high throughout platform for routine screening purposes. Performance of the assay in the miniaturized format is equivalent to that of a standard 96-well assay, showing the same dependence on kinetic parameters and ability to measure enzyme inhibition. The survey screen identified an active class of compounds within the Pharmacopeia compound collection. These results were confirmed using a standard 96-well assay.  相似文献   

3.
4.
The demand to increase throughput in HTS programs, without a concomitant addition to costs, has grown significantly during the past few years. One approach to handle this demand is assay miniaturization, which can provide greater throughput, as well as significant cost savings through reduced reagent costs. Currently, one of the major challenges facing assay miniaturization is the ability to detect the assay signal accurately and rapidly in miniaturized formats. Digital imaging is a detection method that can measure fluorescent or luminescent signals in these miniaturized formats. In this study, an imaging system capable of detecting the signal from a fluorescent protease assay in multiple plate formats was used to evaluate this detection method in an HTS environment. A direct comparison was made between the results obtained from the imaging system and a fluorescent plate reader by screening 8,800 compounds in a 96-well plate format. The imaging system generated similar changes in relative signal for each well in the screen, identified the same active compounds, and yielded similar IC(50) values as compared to the plate reader. When a standard protease inhibitor was evaluated in 96-, 384-, 864-, and 1536-well plates using imaging detection, similar IC(50) values were obtained. Furthermore, similar dose-response curves were generated for the compound in 96- and 384-well assay plates read in a plate reader. These results provide support for digital imaging as an accurate and rapid detection method for high-density microtiter plates.  相似文献   

5.
AequoScreen, a cellular aequorin-based functional assay, has been optimized for luminescent high-throughput screening (HTS) of G protein-coupled receptor (GPCRs). AequoScreen is a homogeneous assay in which the cells are loaded with the apoaequorin cofactor coelenterazine, diluted in assay buffer, and injected into plates containing the samples to be tested. A flash of light is emitted following the calcium increase resulting from the activation of the GPCR by the sample. Here we have validated a new plate reader, the Hamamatsu Photonics FDSS6000, for HTS in 96- and 384-well plates with CHO-K1 cells stably coexpressing mitochondrial apoaequorin and different GPCRs (AequoScreen cell lines). The acquisition time, plate type, and cell number per well have been optimized to obtain concentration-response curves with 4000 cells/well in 384-well plates and a high signal:background ratio. The FDSS6000 and AequoScreen cell lines allow reading of twenty 96- or 384-well plates in 1 h with Z' values of 0.71 and 0.78, respectively. These results bring new insights to functional assays, and therefore reinforce the interest in aequorin-based assays in a HTS environment.  相似文献   

6.
The authors have developed a high-throughput screen (HTS) that allows for the identification of potential inhibitors of the severe acute respiratory syndrome coronavirus (SARS CoV) from large compound libraries. The luminescent-based assay measures the inhibition of SARS CoV-induced cytopathic effect (CPE) in Vero E6 cells. The assay was validated in 96-well plates in a BSL3 containment facility. The assay is sensitive and robust, with Z values > 0.6, signal to background (S/B) > 16, and signal to noise (S/N) > 3. The assay was further validated with 2 different diversity sets of compounds against the SARS CoV. The "hit" rate for both libraries was approximately 0.01%. The validated HTS assay was then employed to screen a 100,000-compound library against SARS CoV. The hit rate for the library in a single-dose format was determined to be approximately 0.8%. Screening of the 3 libraries resulted in the identification of several novel compounds that effectively inhibited the CPE of SARS CoV in vitro-compounds which will serve as excellent lead candidates for further evaluation. At a 10-microM concentration, 3 compounds with selective indexes (SI50) of > 53 were discovered.  相似文献   

7.
A novel competitive binding assay for protein kinase inhibitors has been developed for high-throughput screening (HTS). Unlike functional kinase assays, which are based on detection of substrate phosphorylation by the enzyme, this novel method directly measures the binding potency of compounds to the kinase ATP binding site through competition with a conjugated binding probe. The binding interaction is coupled to a signal amplification system based on complementation of beta-galactosidase enzyme fragments, a homogeneous, nonisotopic assay technology platform developed by DiscoveRx Corp. In the present study, staurosporine, a potent, nonselective kinase inhibitor, was chemically conjugated to a small fragment of beta-galactosidase (termed ED-SS). This was used as the binding probe to the kinase ATP binding pocket. The binding potencies of several inhibitors with diverse structures were assessed by displacement of ED-SS from the kinase. The assay format was specifically evaluated with GSK3alpha, an enzyme previously screened in a radioactive kinase assay (i.e., measurement of [(33)P]-gamma-ATP incorporation into the kinase peptide substrate). Under optimized assay conditions, nonconjugated staurosporine inhibited ED-SS binding in a concentration-dependent manner with an apparent potency (IC(50)) of 11 nM, which was similar to the IC(50) value determined in a radioactive assay. Furthermore, 9 kinase inhibitors with diverse structures, previously identified from chemical compound library screening, were screened using the competitive binding assay. The potencies in the binding assay were in very good agreement with those obtained previously in the isotopic functional activity assay. The binding assay was adapted for automated HTS using selected compound libraries in a 384-well microtiter plate format. The HTS assay was observed to be highly robust and reproducible (Z' factors > 0.7) with high interassay precision (R(2) > 0.96). Interference of compounds with the beta-galactosidase signal readout was negligible. In conclusion, the DiscoveRx competitive kinase binding assay, termed ED-NSIP trade mark, provides a novel method for screening kinase inhibitors. The format is homogeneous, robust, and amenable to automation. Because there is no requirement for substrate-specific antibodies, the assay is particularly applicable to Ser/Thr kinase assay, in which difficulties in identifying a suitable substrate and antibody preclude development of nonisotopic assays. Although the nonselective kinase inhibitor, staurosporine, was used here, chemically conjugating the ED fragment to other small molecule enzyme inhibitors is also feasible, suggesting that the format is generally applicable to other enzyme systems.  相似文献   

8.
Micro Arrayed Compound Screening (microARCS) is a miniaturized ultra-high-throughput screening platform developed at Abbott Laboratories. In this format, 8,640 discrete compounds are spotted and dried onto a polystyrene sheet, which has the same footprint as a 96-well plate. A homogeneous time-resolved fluorescence assay format (LANCE) was applied to identify the inhibitors of caspase-3 using a peptide substrate labeled with a fluorescent europium chelate and a dabcyl quencher. The caspase-3 enzyme was cast into a thin agarose gel, which was placed on a sheet containing test compounds. A second gel containing caspase substrate was then laid above the enzyme gel to initiate the reaction. Caspase-3 cleaves the substrate and separates the europium from the quencher, giving rise to a time-resolved fluorescent signal, which was detected using a ViewLux charge-coupled device imaging system. Potential inhibitors of caspase-3 appeared as dark spots on a bright fluorescent background. Results from the microARCS assay format were compared to those from a conventional 96-well plate-screening format.  相似文献   

9.
This article discusses the development of homogeneous, miniaturized assays for the identification of novel kinase inhibitors from very large compound collections. In particular, the suitability of time-resolved fluorescence resonance energy transfer (TR-RET) based on phospho-specific antibodies, an antibody-independent fluorescence polarization (FP) approach using metal-coated beads (IMAP technology), and the determination of adenosine triphosphate consumption through chemiluminescence is evaluated. These readouts are compared with regard to assay sensitivity, compound interference, reagent consumption, and performance in a 1536-well format, and practical considerations for their application in primary screening or in the identification of kinase substrates are discussed. All of the tested technologies were found to be suitable for miniaturized high-throughput screening (HTS) in principle, but each of them has distinct limitations and advantages. Therefore, the target-specific selection of the most appropriate readout technology is recommended to ensure maximal relevance of HTS campaigns.  相似文献   

10.
G protein-coupled receptors (GPCRs) are involved in various physiological processes, such as behavior changes, mood alteration, and regulation of immune-system activity. Thus, GPCRs are popular targets in drug screening, and a well-designed assay can speed up the discovery of novel drug candidates. The Promega cAMP-Glo Assay is a homogenous bioluminescent assay to monitor changes in intracellular cyclic adenosine monophosphate (cAMP) concentrations in response to the effect of an agonist, antagonist, or test compound on GPCRs. Together with the Labcyte Echo 555 acoustic liquid handler and the Deerac Fluidics Equator HTS reagent dispenser, this setup can screen compounds in 96-, 384-, and 1536-well formats for their effects on GPCRs. Here, we describe our optimization of the cAMP-Glo assay in 1536-well format, validate the pharmacology, and assess the assay robustness for HTS. We have successfully demonstrated the use of the assay in primary screening applications of known agonist and antagonist compounds, and confirmed the primary hits via secondary screening. Implementing a high-throughput miniaturized GPCR assay as demonstrated here allows effective screening for potential drug candidates.  相似文献   

11.
Screens for cytostasis/cytoxicity have considerable value for the discovery of therapeutic agents and the investigation of the biology of apoptosis. For instance, genetic screens for proteins, protein fragments, peptides, RNAs, or chemicals that kill tissue culture cells may aid in identifying new cancer therapeutic targets. A microplate assay for cell death is needed to achieve throughputs sufficient to sift through thousands of agents from expression or chemical libraries. The authors describe a homogeneous assay for cell death in tissue culture cells compatible with 96- or 384-well plates. In combination with a previously described system for retroviral packaging and transduction, nearly 6000 expression library clones could be screened per week in a 96-well plate format. The screening system may also prove useful for chemical screens.  相似文献   

12.
The aim of this study was to investigate the effect of hyperthermia, 6 MeV electron radiation and combination of these treatments on cancer cell line DU145 in both monolayer culture and spheroids enriched for prostate cancer stem cells (CSCs). Flowcytometric analysis of the expression of molecular markers CD133+/CD44+ was carried out to determine the prostate CSCs in cell line DU145 grown as spheroids in serum-free medium. Following monolayer and spheroid culture, DU145 cells were treated with different doses of hyperthermia, electron beam and combination of them. The survival and self-renewing of the cells were evaluated by colony formation assay (CFA) and spheroid formation assay (SFA). Flowcytometry results indicated that the percentage of CD133+/CD44+ cells in spheroid culture was 13.9-fold higher than in the monolayer culture. The SFA showed significant difference between monolayer and spheroid culture for radiation treatment (6 Gy) and hyperthermia (60 and 90 min). The CFA showed significantly enhanced radiosensitivity in DU145 cells grown as monolayer as compared to spheroids, but no effect of hyperthermia. In contrast, for the combination of radiation and hyperthermia the results of CFA and SFA showed a reduced survival fraction in both cultures, with larger effects in monolayer than in spheroid culture. Thus, hyperthermia may be a promising approach in prostate cancer treatment that enhances the cytotoxic effect of electron radiation. Furthermore, determination and characterization of radioresistance and thermoresistance of CSCs in the prostate tumor is the key to develop more efficient therapeutic strategies.  相似文献   

13.
Aberrant regulation of phosphoinositide 3-kinase (PI3K) activity is implicated in various diseases such as cancer and diabetes. Thus, high-throughput screening (HTS) of small-molecule inhibitors for PI3 kinases is an appealing strategy for drug development. Despite the attractiveness of lipid kinases as drug targets, screening for inhibitors for PI3K activities has been hampered by limited assay formats adaptable for HTS. The authors describe a homogeneous, direct, and nonradioactive assay for highly sensitive detection of PI3Kalpha, beta, delta, and gamma activities, which is suitable for HTS. The assay is based on fluorescence superquenching of a conjugated polymer upon metal-ion-mediated association of phosphorylated and dye-labeled substrates. As a result of phosphorylation, quencher and polymer are brought into proximity, and fluorescent energy transfer occurs. This event can be monitored as either fluorescence quench of the polymer or as enhanced emission from the quencher. Ratiometric analysis of the wavelengths eliminates interferences from autofluorescing compounds, which are present in HTS libraries. The platform has been adapted for the 384-well microplate format and delivers Z factors of > 0.6 at substrate conversions as low as 7%. Using this assay platform, several unreported inhibitors and activators of PI3Ks were identified in an 84- compound screen.  相似文献   

14.
A novel FlashPlate scintillation proximity assay has been developed for the high-throughput screening (HTS) of large compound libraries to identify inhibitors of poly(ADP-ribose) polymerase-1 (PARP-1), an important enzyme involved in DNA repair. The assay was originally developed for the 96-well FlashPlate but is easily transferred to a 384-well format. Moreover, the authors demonstrate that the assay is sufficiently sensitive to determine accurate IC(50) values and adaptable for kinetic evaluation of lead molecules. The mechanism of action of the assay requires the binding of PARP-1 to a double-stranded DNA oligonucleotide leading to the active enzyme. Using NAD(+) and (3)H-NAD(+) as substrate, activated PARP-1 synthesizes labeled poly(ADP-ribose) chains. Once the reaction is stopped, ADP-ribose polymers are brought into proximity with the pretreated FlashPlate walls, resulting in signal amplification. This signal is then detected by a TopCount scintillation plate reader. The developed assay is a robust and reproducible method of screening for PARP-1 inhibitors that is low maintenance and cost-effective and can easily be automated.  相似文献   

15.
Although the relevance of three-dimensional (3-D) culture has been recognized for years and exploited at an academic level, its translation to industrial applications has been slow. The development of reliable high-throughput technologies is clearly a prerequisite for the industrial implementation of 3-D models. In this study the robustness of spherical microtissue production and drug testing in a 96-well hanging-drop multiwell plate format was assessed on a standard 96-well channel robotic platform. Microtissue models derived from six different cell lines were produced and characterized according to their growth profile and morphology displaying high-density tissue-like reformation and growth over at least 15 days. The colon cancer cell line HCT116 was chosen as a model to assess microtissue-based assay reproducibility. Within three individual production batches the size variations of the produced microtissues were below 5%. Reliability of the microtissue-based assay was tested using two reference compounds, staurosporine and chlorambucil. In four independent drug testings the calculated IC(50) values were benchmarked against 2-D multiwell testings displaying similar consistency. The technology presented here for the automated production of a variety of microtissues for efficacy testing in a standard 96-well format will aid the implementation of more organotypic models at an early time point in the drug discovery process.  相似文献   

16.
Flow cytometry specializes in high-content measurements of cells and particles in suspension. Having long excelled in analytical throughput of single cells and particles, only recently with the advent of HyperCyt sampling technology, flow cytometry's multiexperiment throughput has begun to approach the point of practicality for efficiently analyzing hundreds-of-thousands of samples, the realm of high-throughput screening (HTS). To extend performance and automation compatibility, we built a HyperCyt-linked Cluster Cytometer platform, a network of flow cytometers for analyzing samples displayed in high-density, 1,536-well plate format. To assess the performance, we used cell- and microsphere-based HTS assays that had been well characterized in the previous studies. Experiments addressed important technical issues: challenges of small wells (assay volumes 10 μL or less, reagent mixing, cell and particle suspension), detecting and correcting for differences in performance of individual flow cytometers, and the ability to reanalyze a plate in the event of problems encountered during the primary analysis. Boosting sample throughput an additional fourfold, this platform is uniquely positioned to synergize with expanding suspension array and cell barcoding technologies in which as many as 100 experiments are performed in a single well or sample. As high-performance flow cytometers shrink in cost and size, cluster cytometry promises to become a practical, productive approach for HTS, and other large-scale investigations of biological complexity.  相似文献   

17.
We have developed a rapid, cost-effective, high-throughput readout for single nucleotide polymorphism (SNP) genotyping using flow cytometric analysis performed on a Luminex 100 flow cytometer. This robust technique employs a PCR-derived target DNA containing the SNP, a synthetic SNP-complementary ZipCode-bearing capture probe, a fluorescent reporter molecule, and a thermophilic DNA polymerase. An array of fluorescent microspheres, covalently coupled with complementary ZipCode sequences (cZipCodes), was hybridized to the reaction products and sequestered them for flow cytometric analysis. The single base chain extension (SBCE) reaction was used to assay 20 multiplexed SNPs for 633 patients in 96-well format. Comparison of the microsphere-based SBCE assay results to gel-based oligonucleotide ligation assay (OLA) results showed 99.3% agreement in genotype assignments. Substitution of direct-labeled R6G dideoxynucleotide with indirect-labeled phycoerythrin dideoxynucleotide enhanced signal five- to tenfold while maintaining low noise levels. A new assay based on allele-specific primer extension (ASPE) was validated on a set of 15 multiplexed SNPs for 96 patients. ASPE offers both the advantage of streamlining the SNP analysis protocol and the ability to perform multiplex SNP analysis on any mixture of allelic variants.  相似文献   

18.
A telomerase assay has been developed for high-throughput screening in 96-well microtiter plates. A crude cell lysate which adds telomere repeats to a biotinylated DNA primer is the source of telomerase. The telomerase-extended primer is hybridized to a digoxigenin-labeled telomere antisense DNA probe. The hybrid is further processed by enzyme-linked immunosorbent assay (ELISA) as follows. The biotinylated hybrid is captured on streptavidin-coated microtiter plates. The immobilized hybrid is probed with alkaline phosphatase-antidigoxigenin and detected via chemiluminescent readout. The limit of detection of a chemically synthesized tetra-telomere repeat was about 10 attomoles. Apparent telomerase activity was detected in lysates of 293T cells. The signal to background for the assay (ratio of signal for the complete assay mixture divided by the signal for the assay mixture without primer) was around 10. An automated system that performed unattended runs of up to 17 96-well microtiter plates in 8h was constructed.  相似文献   

19.
Decreases in mitochondrial membrane potential (MMP) have been associated with mitochondrial dysfunction that could lead to cell death. The MMP is generated by an electrochemical gradient via the mitochondrial electron transport chain coupled to a series of redox reactions. Measuring the MMP in living cells is commonly used to assess the effect of chemicals on mitochondrial function; decreases in MMP can be detected using lipophilic cationic fluorescent dyes. To identify an optimal dye for use in a high-throughput screening (HTS) format, we compared the ability of mitochondrial membrane potential sensor (Mito-MPS), 5,5',6,6'-tetrachloro-1,1',3,3' tetraethylbenzimidazolylcarbocyanine iodide, rhodamine 123, and tetramethylrhodamine to quantify a decrease in MMP in chemically exposed HepG2 cells cultured in 1,536-well plates. Under the conditions used, the optimal dye for this purpose is Mito-MPS. Next, we developed and optimized a homogenous cell-based Mito-MPS assay for use in 1,536-well plate format and demonstrated the utility of this assay by screening 1,280 compounds in the library of pharmacologically active compounds in HepG2 cells using a quantitative high-throughput screening platform. From the screening, we identified 14 compounds that disrupted the MMP, with half-maximal potencies ranging from 0.15 to 18 μM; among these, compound clusters that contained tyrphostin and 3'-substituted indolone analogs exhibited a structure-activity relationship. Our results demonstrate that this homogenous cell-based Mito-MPS assay can be used to evaluate the ability of large numbers of chemicals to decrease mitochondrial function.  相似文献   

20.
The retinoid acid receptor-related orphan receptors (RORs) represent important targets for the treatment of metabolic and immune disorders. Here the authors describe the application of AlphaScreen(?) technology to develop a high-throughput screening (HTS)-compatible assay to facilitate the discovery of RORα modulators. Using the ligand binding domain (LBD) of RORα and a peptide derived from the NR1 box of the nuclear receptor coactivator PGC-1α, a 384-well format assay was developed exhibiting high sensitivity, requiring only low nanomolar concentration of reagents. Recently, it was shown that oxysterols such as 7α-hydroxycholesterol (7α-OHC) function as modulators of the RORs. In this assay, 7α-OHC produced a concentration-response curve with an EC(50) of 162 nM, a Z' factor of 0.6, and a signal-to-background (S/B) ratio of 4.2, demonstrating that the assay is HTS compatible. Validation of the assay was afforded by screening against the Sigma LOPAC1280? library in a 384-well format. In summary, the results presented here demonstrate that this assay can be used to screen large chemical libraries to discover novel modulators of RORα.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号