首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Wiesner J  Premsler T  Sickmann A 《Proteomics》2008,8(21):4466-4483
Despite major advantages in the field of proteomics, the analysis of PTMs still poses a major challenge; thus far, preventing insights into the role and regulation of protein networks. Additionally, top-down sequencing of proteins is another powerful approach to reveal comprehensive information for biological function. A commonly used fragmentation technique in MS-based peptide sequencing is CID. As CID often fails in PTM-analysis and performs best on doubly-charged, short and middle-sized peptides, confident peptide identification may be hampered. A newly developed fragmentation technique, namely electron transfer dissociation (ETD), supports both, PTM- and top-down analysis, and generally results in more confident identification of long, highly charged or modified peptides. The following review presents the theoretical background of ETD and its technical implementation in mass analyzers. Furthermore, current improvements of ETD and approaches for the PTM-analysis and top-down sequencing are introduced. Alternating both fragmentation techniques, ETD and CID, increases the amount of information derived from peptide fragmentation, thereby enhancing both, peptide sequence coverage and the confidence of peptide and protein identification.  相似文献   

2.
Over the last few years we have developed mass spectrometry-based approaches for selective identification of a variety of posttranslational modifications, and for sequencing the modified peptides. These methods do not involve radiolabeling or derivatization. Instead, modification-specific fragment ions are produced by collision-induced dissociation (CID) during analysis of peptides by ESMS. The formation and detection of these marker ions on-the-fly during the LC-ESMS analysis of a protein digest is a powerful technique for identifying posttranslationally modified peptides. Using the marker ion strategy in an orthogonal fashion, a precursor ion scan can detect peptides which give rise to a diagnostic fragment ion, even in an unfractionated protein digest. Once the modified peptide has been located, the appropriate precursor ion can be sequenced by tandem MS. The utility and interplay of this approach to mapping PTM is illustrated with examples that involve protein glycosylation and phosphorylation.  相似文献   

3.
Although tandem mass spectrometry (MS/MS) has become an integral part of proteomics, intensity patterns in MS/MS spectra are rarely weighted heavily in most widely used algorithms because they are not yet fully understood. Here a knowledge mining approach is demonstrated to discover fragmentation intensity patterns and elucidate the chemical factors behind such patterns. Fragmentation intensity information from 28 330 ion trap peptide MS/MS spectra of different charge states and sequences went through unsupervised clustering using a penalized K-means algorithm. Without any prior chemistry assumptions, four clusters with distinctive fragmentation patterns were obtained. A decision tree was generated to investigate peptide sequence motif and charge state status that caused these fragmentation patterns. This data-mining scheme is generally applicable for any large data sets. It bypasses the common prior knowledge constraints and reports on the overall peptide fragmentation behavior. It improves the understanding of gas-phase peptide dissociation and provides a foundation for new or improved protein identification algorithms.  相似文献   

4.
Electron capture dissociation (ECD) and infrared multiphoton dissociation (IRMPD) present complementary techniques for the fragmentation of peptides and proteins in Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) in addition to the commonly used collisionally activated dissociation (CAD). Both IRMPD and ECD have been shown to be applicable for an efficient sequencing of peptides and proteins, whereas ECD has proven especially valuable for mapping labile posttranslational modifications (PTMs), such as phosphorylations. In this work, we compare the different fragmentation techniques and MS detection in a linear ion trap and the ICR cell with respect to their abilities to efficiently identify and characterize phosphorylated peptides. For optimizing fragmentation parameters, sets of synthetic peptides with molecular weights ranging from approximately 1 to 4 kDa and different levels of phosphorylation were analyzed. The influence of spectrum averaging for obtaining high-quality spectra was investigated. Our results show that the fragmentation methods CAD and ECD allow for a facilitated analysis of phosphopeptides; however, their general applicability for analyzing phosphopeptides has to be evaluated in each specific case with respect to the given analytical task. The major advantage of complementary peptide cleavages by combining different fragmentation methods is the increased amount of information that is obtained during MS/MS analysis of modified peptides. On the basis of the obtained results, we are planning to design LC time-scale compatible, data-dependent MS/MS methods using the different fragmentation techniques in order to improve the identification and characterization of phosphopeptides.  相似文献   

5.
The high-throughput nature of proteomics mass spectrometry is enabled by a productive combination of data acquisition protocols and the computational tools used to interpret the resulting spectra. One of the key components in mainstream protocols is the generation of tandem mass (MS/MS) spectra by peptide fragmentation using collision induced dissociation, the approach currently used in the large majority of proteomics experiments to routinely identify hundreds to thousands of proteins from single mass spectrometry runs. Complementary to these, alternative peptide fragmentation methods such as electron capture/transfer dissociation and higher-energy collision dissociation have consistently achieved significant improvements in the identification of certain classes of peptides, proteins, and post-translational modifications. Recognizing these advantages, mass spectrometry instruments now conveniently support fine-tuned methods that automatically alternate between peptide fragmentation modes for either different types of peptides or for acquisition of multiple MS/MS spectra from each peptide. But although these developments have the potential to substantially improve peptide identification, their routine application requires corresponding adjustments to the software tools and procedures used for automated downstream processing. This review discusses the computational implications of alternative and alternate modes of MS/MS peptide fragmentation and addresses some practical aspects of using such protocols for identification of peptides and post-translational modifications.  相似文献   

6.
This paper reports on studies directed to the characterization of the proteome of human plasma by the shotgun sequencing approach, namely the use of HPLC coupled to mass spectrometry (MS). The report will present data from two laboratories that allows the comparison of peptide and protein identifications by either accurate mass measurement on a Fourier transform mass spectrometry or MS/MS fragmentation on an ion trap mass spectrometer. Because the dynamic range of the protein components of plasma is one of the largest for a biological sample, the analysis of such a challenging sample was aided by the use of these two MS approaches. The major classes of proteins observed were transport proteins, enzymes, and enzyme inhibitors, blood-clotting factors, membrane-associated proteins including soluble forms of receptors, hormones, immunoglobulins, and other glycoproteins. The protein identifications were also highly consistent with results obtained from 2D gel studies, although a larger number of additional proteins were observed with the shotgun sequencing approach. The quantitation of low to medium level proteins was explored in the ion trap with an add-back of a known amount of human growth hormone (hGH) at a clinically relevant level (5 ug/L). The isotope coded affinity tag (ICAT) approach was used to quantitate successfully different levels of hGH in replicate analysis via the disulfide linked tryptic peptide (T6-T16). These studies suggest that the shotgun sequencing approach can be used to characterize part of the plasma proteome and serve as a starting point for the use of multidimensional analytical approaches for the analysis of complex biological samples.  相似文献   

7.
Mass spectrometry has become a key technology for modern large-scale protein sequencing. Tandem mass spectrometry, the process of peptide ion dissociation followed by mass-to-charge ratio (m/z) analysis, is the critical component for peptide identification. Recent advances in mass spectrometry now permit two discrete, and complementary, types of peptide ion fragmentation: collision-activated dissociation (CAD) and electron transfer dissociation (ETD) on a single instrument. To exploit this complementarity and increase sequencing success rates, we designed and embedded a data-dependent decision tree algorithm (DT) to make unsupervised, real-time decisions of which fragmentation method to use based on precursor charge and m/z. Applying the DT to large-scale proteome analyses of Saccharomyces cerevisiae and human embryonic stem cells, we identified 53,055 peptides in total, which was greater than by using CAD (38,293) or ETD (39,507) alone. In addition, the DT method also identified 7,422 phosphopeptides, compared to either 2,801 (CAD) or 5,874 (ETD) phosphopeptides.  相似文献   

8.
Two-dimensional gel electrophoresis-separated and excised haptoglobin alpha2-chain protein spots were subjected to in-gel digestion with trypsin. Previously unassigned peptide ion signals observed in mass spectrometric fingerprinting experiments were sequenced using the matrix-assisted laser desorption/ionization-quadrupole ion trap-time of flight (MALDI-QIT-TOF) mass spectrometer and showed that the haptoglobin alpha-chain derivative under study was cleaved by trypsin unspecifically. Abundant cleavages occurred C-terminal to histidine residues at H23, H28, and H87. In addition, mild acidic hydrolysis leading to cleavage after aspartic acid residues at D13 was observed. The uninterpreted tandem mass spectrometry (MS/MS) spectrum of the peptide with ion signal at 2620.19 was submitted to database search and yielded the identification of the corresponding peptide sequence comprising amino acids (aa) aa65-87 from the haptoglobin alpha-chain protein. Also, the presence of a mixture of two tryptic peptides (mass to charge ratio m/z 1708.8; aa40-54, and aa99-113, respectively), that is caused by a tiny sequence variation between the two repeats in the haptoglobin alpha2-chain protein was resolved by MS/MS fragmentation using the MALDI-QIT-TOF mass spectrometer instrument. Advantageous features such as (i) easy parent ion creation, (ii) minimal sample consumption, and (iii) real collision induced dissociation conditions, were combined successfully to determine the amino acid sequences of the previously unassigned peptides. Hence, the novel mass spectrometric sequencing method applied here has proven effective for identification of distinct molecular protein structures.  相似文献   

9.
In proteomic studies, assigning protein identity from organisms whose genomes are yet to be completely sequenced remains a challenging task. For these organisms, protein identification is typically based on cross species matching of amino acid sequence obtained from collision induced dissociation (CID) of peptides using mass spectrometry. The most direct approach of de novo sequencing is slow and often difficult, due to the complexity of the resultant CID spectra. For MALDI-MS, this problem has been addressed by using chemical derivatisation to direct peptide fragmentation, thereby simplifying CID spectra and facilitating de novo interpretation. In this study, milk whey proteins from the tammar wallaby (Macropus eugenii) were used to evaluate three chemical derivatisation methods compatible with MALDI MS/MS. These methods included (i) guanidination and sulfonation using chemically-assisted fragmentation (CAF), (ii) guanidination and sulfonation using 4-sulfophenyl isothiocyanate (SPITC) and (iii) derivatising the epsilon-amino group of lysine residues with Lys Tag 4H. Derivatisation with CAF and SPITC resulted in more protein identification than Lys Tag 4H. Sulfonation using SPITC was the preferred method due to the low cost per experiment, the reactivity with both lysine and arginine terminated peptides and the resultant simplified MS/MS spectra.*Australian Peptide Conference Issue.**This project was funded by an ARC Linkage grant to Deane supported by TGR Biosciences and facilitated by access to the Australian Proteome Analysis Facility established under the Australian Government’s Major National Research Facilities program.  相似文献   

10.
Mass spectrometric based sequencing of enzymatic generated peptides is widely used to obtain specific sequence tags allowing the unambiguous identification of proteins. In the present study, two types of desorption/ionization techniques combined with different modes of ion dissociation, namely vacuum matrix-assisted laser desorption/ionization (vMALDI) high energy collision induced dissociation (CID) and post-source decay (PSD) as well as atmospheric pressure (AP)-MALDI low energy CID, were applied for the fragmentation of singly protonated peptide ions, which were derived from two-dimensional separated, silver-stained and trypsin-digested hydrophilic as well as hydrophobic glomerular proteins. Thereby, defined properties of the individual fragmentation pattern generated by the specified modes could be observed. Furthermore, the compatibility of the varying PSD and CID (MS/MS) data with database search derived identification using two public accessible search algorithms has been evaluated. The peptide sequence tag information obtained by PSD and high energy CID enabled in the majority of cases an unambiguous identification. In contrast, part of the data obtained by low energy CID were not assignable using similar search parameters and therefore no clear results were obtainable. The knowledge of the properties of available MALDI-based fragmentation techniques presents an important factor for data interpretation using public accessible search algorithms and moreover for the identification of two-dimensional gel separated proteins.  相似文献   

11.
Abstract Several approaches exist for the quantification of proteins in complex samples processed by liquid chromatography-mass spectrometry followed by fragmentation analysis (MS2). One of these approaches is label-free MS2-based quantification, which takes advantage of the information computed from MS2 spectrum observations to estimate the abundance of a protein in a sample. As a first step in this approach, fragmentation spectra are typically matched to the peptides that generated them by a search algorithm. Because different search algorithms identify overlapping but non-identical sets of peptides, here we investigate whether these differences in peptide identification have an impact on the quantification of the proteins in the sample. We therefore evaluated the effect of using different search algorithms by examining the reproducibility of protein quantification in technical repeat measurements of the same sample. From our results, it is clear that a search engine effect does exist for MS2-based label-free protein quantification methods. As a general conclusion, it is recommended to address the overall possibility of search engine-induced bias in the protein quantification results of label-free MS2-based methods by performing the analysis with two or more distinct search engines.  相似文献   

12.
Protonated peptides derived from proline‐rich proteins (PRP) are often difficult to sequence by standard collision‐induced dissociation (CID) mass spectrometry (MS) due to preferential amide bond cleavage N‐terminal to proline. In connection with bovine spongiform encephalopathy regulations, proteolytic products derived from the PRP collagen have been suggested as markers for contamination of animal feedstuffs with processed animal protein (Fernandez Ocaña, M. et al., Analyst 2004, 129, 111–115). Herein, we report the identification of these marker peptides using the strategy of C‐terminal sequencing by CID MS from their sodium and lithium adducts. Upon fragmentation a new cationized peptide was produced that is one C‐terminal amino acid shorter in length. This dissociation pathway allowed for the facile identification of the C‐terminal residue by matrix‐assisted laser desorption/ionization tandem time‐of‐flight mass spectrometry. Each newly formed cationized peptide was further fragmented by up to seven stages of electrospray ionization ion trap MS. Proline‐rich C‐terminal sequence tags were established which permitted successful database identification of collagen alpha type I proteins.  相似文献   

13.
Protein identification has been greatly facilitated by database searches against protein sequences derived from product ion spectra of peptides. This approach is primarily based on the use of fragment ion mass information contained in a MS/MS spectrum. Unambiguous protein identification from a spectrum with low sequence coverage or poor spectral quality can be a major challenge. We present a two-dimensional (2D) mass spectrometric method in which the numbers of nitrogen atoms in the molecular ion and the fragment ions are used to provide additional discriminating power for much improved protein identification and de novo peptide sequencing. The nitrogen number is determined by analyzing the mass difference of corresponding peak pairs in overlaid spectra of (15)N-labeled and unlabeled peptides. These peptides are produced by enzymatic or chemical cleavage of proteins from cells grown in (15)N-enriched and normal media, respectively. It is demonstrated that, using 2D information, i.e., m/z and its associated nitrogen number, this method can, not only confirm protein identification results generated by MS/MS database searching, but also identify peptides that are not possible to identify by database searching alone. Examples are presented of analyzing Escherichia coli K12 extracts that yielded relatively poor MS/MS spectra, presumably from the digests of low abundance proteins, which can still give positive protein identification using this method. Additionally, this 2D MS method can facilitate spectral interpretation for de novo peptide sequencing and identification of posttranslational or other chemical modifications. We envision that this method should be particularly useful for proteome expression profiling of organelles or cells that can be grown in (15)N-enriched media.  相似文献   

14.
Hernandez P  Gras R  Frey J  Appel RD 《Proteomics》2003,3(6):870-878
In recent years, proteomics research has gained importance due to increasingly powerful techniques in protein purification, mass spectrometry and identification, and due to the development of extensive protein and DNA databases from various organisms. Nevertheless, current identification methods from spectrometric data have difficulties in handling modifications or mutations in the source peptide. Moreover, they have low performance when run on large databases (such as genomic databases), or with low quality data, for example due to bad calibration or low fragmentation of the source peptide. We present a new algorithm dedicated to automated protein identification from tandem mass spectrometry (MS/MS) data by searching a peptide sequence database. Our identification approach shows promising properties for solving the specific difficulties enumerated above. It consists of matching theoretical peptide sequences issued from a database with a structured representation of the source MS/MS spectrum. The representation is similar to the spectrum graphs commonly used by de novo sequencing software. The identification process involves the parsing of the graph in order to emphasize relevant sections for each theoretical sequence, and leads to a list of peptides ranked by a correlation score. The parsing of the graph, which can be a highly combinatorial task, is performed by a bio-inspired algorithm called Ant Colony Optimization algorithm.  相似文献   

15.
In tandem mass spectrometry (MS/MS), there are several different fragmentation techniques possible, including, collision‐induced dissociation (CID) higher energy collisional dissociation (HCD), electron‐capture dissociation (ECD), and electron transfer dissociation (ETD). When using pairs of spectra for de novo peptide sequencing, the most popular methods are designed for CID (or HCD) and ECD (or ETD) spectra because of the complementarity between them. Less attention has been paid to the use of CID and HCD spectra pairs. In this study, a new de novo peptide sequencing method is proposed for these spectra pairs. This method includes a CID and HCD spectra merging criterion and a parent mass correction step, along with improvements to our previously proposed algorithm for sequencing merged spectra. Three pairs of spectral datasets were used to investigate and compare the performance of the proposed method with other existing methods designed for single spectrum (HCD or CID) sequencing. Experimental results showed that full‐length peptide sequencing accuracy was increased significantly by using spectra pairs in the proposed method, with the highest accuracy reaching 81.31%.  相似文献   

16.
Although genome databases have become the key for proteomic analyses, de novo sequencing remains essential for the study of organisms whose genomes have not been completed. In addition, post-translational modifications present a challenge in database searching. Recognition of the b or y-ion series in a peptide MS/MS spectrum as well as identification of the b1 - and yn-1 -ions can facilitate de novo analyses. Therefore, it is valuable to identify either amino-acid terminus. In previous work, we have demonstrated that peptides modified at the epsilon-amino group of lysine as a t-butyl peroxycarbamate derivative undergo free radical promoted peptide backbone fragmentation under low-energy collision-induced dissociation (CID) conditions. Here we explore the chemistry of the N-terminal amino group modified as a t-butyl peroxycarbamate. The conversion of N-terminal amines to peroxycarbamates of simple amino acids and peptides was studied with aryl t-butyl peroxycarbonates. ESI-MS/MS analysis of the peroxycarbamate adducts gave evidence of a product ion corresponding to the neutral loss of the N-terminal side chain (R), thus identifying this residue. Further fragmentation (MS3) of product ions formed by N-terminal residue side-chain loss (-R) exhibited an m/z shift of the b-ions equal to the neutral loss of R, therefore labeling the b-ion series. The study was extended to the analysis of a protein tryptic digest where the SALSA algorithm was used to identify spectra containing these neutral losses. The method for N-terminus identification presented here has the potential for improvement of de novo analyses as well as in constraining peptide mass mapping database searches.  相似文献   

17.
Comparative proteomic approaches using isotopic labeling and MS have become increasingly popular. Conventionally quantification is based on MS or extracted ion chromatogram (XIC) signals of differentially labeled peptides. However, in these MS-based experiments, the accuracy and dynamic range of quantification are limited by the high noise levels of MS/XIC data. Here we report a quantitative strategy based on multiplex (derived from multiple precursor ions) MS/MS data. One set of proteins was metabolically labeled with [13C6]lysine and [15N4]arginine; the other set was unlabeled. For peptide analysis after tryptic digestion of the labeled proteins, a wide precursor window was used to include both the light and heavy versions of each peptide for fragmentation. The multiplex MS/MS data were used for both protein identification and quantification. The use of the wide precursor window increased sensitivity, and the y ion pairs in the multiplex MS/MS spectra from peptides containing labeled and unlabeled lysine or arginine offered more information for, and thus the potential for improving, protein identification. Protein ratios were obtained by comparing intensities of y ions derived from the light and heavy peptides. Our results indicated that this method offers several advantages over the conventional XIC-based approach, including increased sensitivity for protein identification and more accurate quantification with more than a 10-fold increase in dynamic range. In addition, the quantification calculation process was fast, fully automated, and independent of instrument and data type. This method was further validated by quantitative analysis of signaling proteins in the EphB2 pathway in NG108 cells.  相似文献   

18.
The field of proteomics continues to be driven by improvements in analytical technology, notably in peptide separation, quantitative MS, and informatics. In this study, we have characterized a hybrid linear ion trap high field Orbitrap mass spectrometer (Orbitrap Elite) for proteomic applications. The very high resolution available on this instrument allows 95% of all peptide masses to be measured with sub‐ppm accuracy that in turn improves protein identification by database searching. We further confirm again that mass accuracy in tandem mass spectra is a valuable parameter for improving the success of protein identification. The new CID rapid scan type of the Orbitrap Elite achieves similar performance as higher energy collision induced dissociation fragmentation and both allow the identification of hundreds of proteins from as little as 0.1 ng of protein digest on column. The new instrument outperforms its predecessor the Orbitrap Velos by a considerable margin on each metric assessed that makes it a valuable and versatile tool for MS‐based proteomics.  相似文献   

19.
Next to the identification of proteins and the determination of their expression levels, the analysis of post-translational modifications (PTM) is becoming an increasingly important aspect in proteomics. Here, we review mass spectrometric (MS) techniques for the study of protein glycosylation at the glycopeptide level. Enrichment and separation techniques for glycoproteins and glycopeptides from complex (glyco-)protein mixtures and digests are summarized. Various tandem MS (MS/MS) techniques for the analysis of glycopeptides are described and compared with respect to the information they provide on peptide sequence, glycan attachment site and glycan structure. Approaches using electrospray ionization and matrix-assisted laser desorption/ionization (MALDI) of glycopeptides are presented and the following fragmentation techniques in glycopeptide analysis are compared: collision-induced fragmentation on different types of instruments, metastable fragmentation after MALDI ionization, infrared multi-photon dissociation, electron-capture dissociation and electron-transfer dissociation. This review discusses the potential and limitations of tandem mass spectrometry of glycopeptides as a tool in structural glycoproteomics.  相似文献   

20.
Electron transfer dissociation (ETD) has been developed recently as an efficient ion fragmentation technique in mass spectrometry (MS), being presently considered a step forward in proteomics with real perspectives for improvement, upgrade and application. Available also on affordable ion trap mass spectrometers, ETD induces specific N–Cα bond cleavages of the peptide backbone with the preservation of the post-translational modifications and generation of product ions that are diagnostic for the modification site(s). In addition, in the last few years ETD contributed significantly to the development of top-down approaches which enable tandem MS of intact protein ions. The present review, covering the last 5 years highlights concisely the major achievements and the current applications of ETD fragmentation technique in proteomics. An ample part of the review is dedicated to ETD contribution in the elucidation of the most common posttranslational modifications, such as phosphorylation and glycosylation. Further, a brief section is devoted to top-down by ETD method applied to intact proteins. As the last few years have witnessed a major expansion of the microfluidics systems, a few considerations on ETD in combination with chip-based nanoelectrospray (nanoESI) as a platform for high throughput top-down proteomics are also presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号