首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We have estimated the intrinsic mechanical parameters of cricket cercal wind-receptor hairs. The hairs were modeled as an inverted pendulum, and mechanical parameters of the equation of motion were determined from data given by a systematic measurement of mobility by the least-square error method. The theoretical torque which turns the hair shaft is given by the drag force due to the moving air. The drag force is given by the method of Stokes' mechanical impedance of an oscillating cylinder in viscous fluid. The effect of the boundary layer in which air is stagnating on the substrate surface is also taken into account. The moment of inertia of a hair shaft shows a clear length dependency to the power of 4.32 of the hair length. The torsional resistance within the hair base and the stiffness of hair-supporting spring also show clear length dependencies to the power of 2.77 and 1.67, respectively. The torsional resistance within the hair base is so large that the hair is a strongly damped non-oscillatory second-order system. The large resistance within the hair base represents an efficient energy absorption by the sensory cell. The resistance seems to match with the source impedance, i.e., the frictional resistance at the site of air-hair contact. The impedance matching provides the condition of maximum power transmission from the moving air to the sensory cell. Structural scaling is discussed in relation to the functional scaling of the frequency-range fractionation of the mechanical filter array with a common biological design. Accepted: 24 February 1998  相似文献   

2.
The external resistance is perhaps the easiest way to influence the operation of a microbial fuel cell (MFC). In this paper, three enrichment strategies, whereby the external resistance was fixed at: (1) a high value in order to maximize the cell voltage (U strategy); (2) a low value in order to maximize the current (I strategy); and (3) a value equal to the internal resistance of the MFC to maximize the power output (P strategy), were investigated. The I strategy resulted in increased maximum power generation and the likely reason is that electron transfer was facilitated under low external resistance, which in turn, favored the development of an electrochemically active biofilm. This experiment was conducted in a single-chamber MFC system equipped with a membrane electrode assembly, and a comparison of the performance achieved by five different membranes is also provided. Selemion was found to be a suitable alternative to Nafion.  相似文献   

3.
Plantarflexion resistance of an ankle-foot orthosis (AFO) plays an important role to prevent foot-drop, but its impact on push-off has not been well investigated in individuals post-stroke. The aim of this study was to investigate the effect of plantarflexion resistance of an articulated AFO on ankle and knee joint power of the limb wearing the AFO in individuals post-stroke. Gait analysis was performed on 10 individuals with chronic stroke using a Vicon 3-dimensional motion capture system and a Bertec split-belt instrumented treadmill. They walked on the treadmill under 4 plantarflexion resistance levels (S1 < S2<S3 < S4) set on the AFO with resistance adjustable ankle joints. The ankle and knee joint power calculations were performed using Visual3D, and mean values were plotted across a gait cycle. Statistical analyses revealed significant differences in the peak ankle joint power generation according to the plantarflexion resistance of the AFO (P = 0.008). No significant differences were found in the knee joint power. Peak ankle joint power generation [Median (IQR: Interquartile range)] were S1: 0.0517 (0.0238–0.1071) W/kg, S2: 0.0342 (0.0132–0.0862) W/kg, S3: 0.0353 (0.0127–0.0821) W/kg, and S4: 0.0234 (0.0087–0.06764) W/kg. Reduction of the peak ankle joint power generation appeared to be related to reduction in the peak plantarflexion angular velocity at late stance due to increases in the plantarflexion resistance of the AFO. This study showed that peak ankle joint power generation was significantly, and somewhat systematically, affected by plantarflexion resistance of the AFO in individuals post-stroke.  相似文献   

4.
Cardiomyoplasty is a procedure developed to improve heart performance in patients suffering from congestive heart failure. The latissimus dorsi (LD) muscle is surgically wrapped around the failing ventricles and stimulated to contract in synchrony with the heart. The LD muscle is easily fatigued and as a result is unsuitable for cardiomyoplasty. For useful operation as a cardiac-assist device, the fatigue resistance of the LD muscle must be improved while retaining a high power output. The LD muscle of rabbits was subjected to a training regime in which cyclic work was performed. Training transformed the fiber-type composition from approximately equal proportions of fast oxidative glycolytic (FOG) and fast glycolytic (FG) fibers to one composed of almost entirely of FOG with no FG, which increased fatigue resistance while retaining rapid contraction kinetics. Muscle mass and cross-sectional area increased but power output decreased, relative to control muscles. This training regime represents a significant improvement in terms of preserving muscle mass and power compared with other training regimes, while enhancing fatigue resistance, although some fiber damage occurred. The power output of the trained LD muscle was calculated to be sufficient to deliver a significant level of assistance to a failing heart during cardiomyoplasty.  相似文献   

5.
The electrical field used in electrophoresis can be produced by various types of electrical power supplies. The optimum power supply, with respect to the ratio of migration velocity to heating, produces the maximum voltage gradient consistent with the maximum allowable rate of heating. The voltage and current change only to compensate for changes in the resistance of the electrophoretic system. A circuit is given which produces such constant power and its operation is compared with other types of regulation.  相似文献   

6.
This study investigated the effect on upper-body power output of manipulating resistances during contrast or complex power training. This power-training strategy typically entails the athlete alternating sets of a heavy resistance in a strength-oriented exercise with sets of lighter resistances in a power-oriented exercise. Sixteen rugby league players, who were experienced in power training and who performed complex training on a regular basis, served as subjects for this study and were divided equally into a control (Con) or experimental (Exp) group. Both groups were pre- and posttested for power output while performing explosive bench press throws in a Smith machine with a resistance of 50 kg (BT P50). The Exp group performed an intervention strategy of a 6-repetition set of bench presses with a resistance of 65% of 1 repetition maximum (65% 1RM) between tests. At the pretest occasion, no differences were observed between the groups in power output; however, at the posttesting, a significant difference in power output was observed between the groups in the BT P50. The 4.5% increase in the power output recorded during the posttesting BT P50 for the Exp group was determined to be significantly different from all other scores (p < or = 0.05). These data indicate that the performance of a set of heavy resistance strength training exercise between power training sets will acutely enhance power output in the second power training set. This effect has been previously theorized as possibly due to some combination of acute neural or mechanical adaptations.  相似文献   

7.
Predictions of added resistance and the effective power of ships were made for varying barnacle fouling conditions. A series of towing tests was carried out using flat plates covered with artificial barnacles. The tests were designed to allow the examination of the effects of barnacle height and percentage coverage on the resistance and effective power of ships. The drag coefficients and roughness function values were evaluated for the flat plates. The roughness effects of the fouling conditions on the ships’ frictional resistances were predicted. Added resistance diagrams were then plotted using these predictions, and powering penalties for these ships were calculated using the diagrams generated. The results indicate that the effect of barnacle size is significant, since a 10% coverage of barnacles each 5 mm in height caused a similar level of added power requirements to a 50% coverage of barnacles each 1.25 mm in height.  相似文献   

8.
It is often recommended that in-season training programs aim to maintain muscular strength and power developed during the off-season. However, improvements in performance may be possible with a well-designed training regimen. The purpose of this case report is to describe the changes in physical performance after an in-season training regimen in professional female volleyball players in order to determine whether muscular strength and power might be improved. Apart from normal practice sessions, 10 elite female volleyball players completed 2 training sessions per week, which included both resistance training and plyometric exercises. Over the 12-week season, the athletes performed 3-4 sets of 3-8 repetitions for resistance and plyometric exercises during each training session. All sessions were supervised by one of the investigators as well as by the team head coach. Muscular strength and power were assessed before and after the 12-week training program using 4 repetition maximum bench press and parallel squat tests, an overhead medicine ball throw (BTd), as well as unloaded and loaded countermovement jumps (CMJs). Strength improved by 15% and 11.5% in the bench press and parallel squat, respectively (p < 0.0001). Distance in the BTd improved by 11.8% (p < 0.0001), whereas unloaded and loaded CMJ height increased between 3.8 and 11.2%. The current findings suggest that elite female volleyball players can improve strength and power during the competition season by implementing a well-designed training program that includes both resistance and plyometric exercises.  相似文献   

9.
Carbon nanotube (CNT) is a promising electrode material and has been used as an anode modifier in microbial fuel cells (MFCs). In this study, a new method of simultaneously adding CNT powders and Geobacter sulfurreducens into the anode chamber of a MFC was used, aiming to form a composite biofilm on the anode. The performance of MFCs such as startup time and steady-state power generation was investigated under conditions of different CNT powders dosages. Results showed that both the startup time and the anodic resistance were reduced. The optimal dosage of CNT powders pre-treated by acid was 4 mg/mL for the anode chamber with an effective volume of 25 mL. The anodic resistance and output voltage of the MFC with CNT powders addition were maintained around 180 Ω and 650 mV during 40 days operation, while those of the MFC without CNT powders addition increased from 250 Ω to 540 Ω and decreased from 630 mV to 540 mV, respectively, demonstrating that adding CNT powders helped stabilize the anodic resistance, thus the internal resistance and power generation during long-term operation. Based on cyclic voltammogram, the electrochemical activity of anodic biofilm was enhanced by adding CNT powders, though no significant increase of the biomass in anodic biofilm was detected by phospholipids analysis. There was no remarkable change of ohmic resistance with an addition of CNT powders revealed by current interrupt method, which indicated that the rate of mass transfer might be promoted by the presence of CNT powders.  相似文献   

10.
Training to develop superior muscular power has become a key component to most progressive sport conditioning programs. Conventional resistance training, plyometrics, and speed/agility modalities have all been employed in an effort to realize superlative combinations of training stimuli. New training devices such as the VertiMax resisted jump trainer are marketed as a means of improving lower body reactive power. The purpose of this study was to evaluate the effectiveness of the VertiMax, in combination with traditional training modalities, for improvements in lower body power among highly trained athletes. Forty men and women Division I collegiate athletes representing the sports of baseball, basketball, soccer, gymnastics, and track completed a 12-week mixed-methods training program. Two groups were constructed with both groups performing the same conventional resistance training and strength training exercises. The training control group performed traditional plyometric exercises while the experimental group performed similar loaded jump training on the VertiMax. Lower body power was measured before and after the training program by the TENDO FiTROdyne Powerlizer and statistically compared for differences between groups. Data analyses identified a significant (p < 0.05) and meaningful difference between power development among the 2 groups, with the VertiMax eliciting a greater treatment effect (effect size = 0.54) over conventional resistance and plyometric training alone (effect size = 0.09). These data convincingly demonstrate that the VertiMax represents an effective strategy for developing lower body power among trained college athletes, when combined with traditional strength and conditioning approaches.  相似文献   

11.
BACKGROUND: Estimating the duration of forced exhalation tracheal noises shows promise for recognizing bronchial obstruction. OBJECTIVE: Experimental simulation of an influence of biomechanical parameters on the duration of normal forced exhalation tracheal noises. METHOD AND MATERIALS: Thirty-two healthy non-smoking men aged 16-22 years were examined. The duration of noises, the parameters of computer spirometry, and the maximum static expiratory pressure are recorded. These data were analyzed by means of multiple linear regression simulation for logarithms of the elements of the proportionality relation obtained with the use of a one-component biomechanical model of forced exhalation and a linearized approximation of flow-volume curve. RESULTS: Dependence between duration of the forced expiratory noises recorded on human trachea and the product of forced volume capacity (in power of 1.05 +/- 0.27), maximum static expiratory pressure (in power of 0.46 +/- 0.23), equivalent expiratory resistance in the stage of functional expiratory stenosis (in power of 0.72 +/- 0.15 in healthy is an estimate of the equivalent expiratory resistance of human bronchial tree in the functional expiratory stenosis phase, whereas in patients with bronchial obstruction it is supposed to take into account an excess of noise generation time compared with the time predicted from normal individual value of this resistance.  相似文献   

12.
The author derived the exact analytical expression of the instantaneous joint power in exercises with single-joint, variable-resistance, selectorized strength-training equipment, taking into account all the relevant geometric, kinematic, and dynamic variables of both the movable equipment elements (resistance input lever, cam-pulley system, weight stack) and of the user's exercising limb. A numerical algorithm was also designed to express, in the presence of a cam, the rectilinear kinematic variables of the weight stack as a function of the rotational kinematic variables of the resistance input lever, and vice versa. Given that information, one can measure the value of the instantaneous and mean joint power exclusively by means of a linear encoder placed on the weight stack or, alternatively, only by the use of an angular encoder placed on the rotational axis of the resistance lever. The results highlight that, for knee extension exercises with leg extension equipment, the real values of both instantaneous and mean joint power may differ by more than 50% in comparison with the values obtained by taking into account only the mass and velocity of the weight stack. These differences are notable not only in explosive exercises, but also whenever considerable joint velocities/accelerations occur within the range of motion.  相似文献   

13.
The purpose of the experiment was to examine how force, speed and power output of horizontal pulling with the upper limb was affected by the height of pull. Fourteen seated male subjects made horizontal pulls with maximal effort at eye, shoulder and elbow level from their positions of full reach when the trunk and shoulder girdle were rigidly constrained. Dynamic pulls were performed against a water-filled viscous dynamometer in which the resistance, proportional to the square of the velocity, could be varied. The height of pull had no significant effect on either static or dynamic performance. A force-velocity-position surface is presented which describes the conditions at the handle during the pulls. It confirms the importance of degree of reach upon the dynamic performance, and over a greater range of velocities than has been studied previously. A simple model shows that the similarity of performance at eye, shoulder and elbow heights is remarkable because they occur under very different biomechanical circumstances. The total work done in a complete pull increases with resistance. Peak power output is obtained against the same resistance (50 kg m-1) that was reported for elbow flexion and standing pulls.  相似文献   

14.
Trade-offs arise when two functional traits impose conflicting demands on the same design trait. Consequently, excellence in one comes at the cost of performance in the other. One of the most widely studied performance trade-offs is the one between sprint speed and endurance. Although biochemical, physiological and (bio)mechanical correlates of either locomotor trait conflict with each other, results at the whole-organism level are mixed. Here, we test whether burst (speed, acceleration) and sustained locomotion (stamina) trade off at both the isolated muscle and whole-organism level among 17 species of lacertid lizards. In addition, we test for a mechanical link between the organismal and muscular (power output, fatigue resistance) performance traits. We find weak evidence for a trade-off between burst and sustained locomotion at the whole-organism level; however, there is a significant trade-off between muscle power output and fatigue resistance in the isolated muscle level. Variation in whole-animal sprint speed can be convincingly explained by variation in muscular power output. The variation in locomotor stamina at the whole-organism level does not relate to the variation in muscle fatigue resistance, suggesting that whole-organism stamina depends not only on muscle contractile performance but probably also on the performance of the circulatory and respiratory systems.  相似文献   

15.
The influence of study design on the ability to detect the effects of landscape pattern on gene flow is one of the most pressing methodological gaps in landscape genetic research. To investigate the effect of study design on landscape genetics inference, we used a spatially‐explicit, individual‐based program to simulate gene flow in a spatially continuous population inhabiting a landscape with gradual spatial changes in resistance to movement. We simulated a wide range of combinations of number of loci, number of alleles per locus and number of individuals sampled from the population. We assessed how these three aspects of study design influenced the statistical power to successfully identify the generating process among competing hypotheses of isolation‐by‐distance, isolation‐by‐barrier, and isolation‐by‐landscape resistance using a causal modelling approach with partial Mantel tests. We modelled the statistical power to identify the generating process as a response surface for equilibrium and non‐equilibrium conditions after introduction of isolation‐by‐landscape resistance. All three variables (loci, alleles and sampled individuals) affect the power of causal modelling, but to different degrees. Stronger partial Mantel r correlations between landscape distances and genetic distances were found when more loci were used and when loci were more variable, which makes comparisons of effect size between studies difficult. Number of individuals did not affect the accuracy through mean equilibrium partial Mantel r, but larger samples decreased the uncertainty (increasing the precision) of equilibrium partial Mantel r estimates. We conclude that amplifying more (and more variable) loci is likely to increase the power of landscape genetic inferences more than increasing number of individuals.  相似文献   

16.
Modelling the hydrodynamic resistance of bordered pits   总被引:1,自引:0,他引:1  
Previous studies of the hydrodynamics of plant stems have shown that resistance to flow through bordered pits on the side walls of tracheids makes up a significant proportion of their total resistance, and that this proportion increases with tracheid diameter. This suggests a possible reason why tracheids with a diameter above around 100 microm have failed to evolve. This possibility has been investigated by obtaining an estimate for the resistance of a single pit, and incorporating it into analytical models of tracheid resistance and wood resistivity. The hydrodynamic resistance of the bordered pits of Tsuga canadensis was investigated using large-scale physical models. The importance of individual components of the pit were investigated by comparing the resistance of models with different pore sizes in their pit membrane, and with or without the torus and border. The estimate for the resistance of a real bordered pit was 1.70x10(15) Pa s m(-3). Resistance of pits varied with morphology as might be predicted; the resistance was inversely proportional to the pore size to the power of 0.715; removing the torus reduced resistance by 28%, while removal of the torus and border together reduced it by 72%. It was estimated that in a 'typical tracheid' pit resistance should account for 29% of the total. Incorporating the results into the model for the resistivity of wood showed that resistivity should fall as tracheid diameter increases. However, to minimize resistance wider tracheids would also need to be proportionally much longer. It is suggested that the diameter of tracheids in conifers is limited by upper limits to cell length or cell volume. This limitation is avoided by angiosperms because they can digest away the ends of their cells to produce long, wide vessels composed of many short cells.  相似文献   

17.
The measured dependences of the equivalent plasma resistance on the external magnetic field (0–50 G) in a 46-cm-diameter RF inductive plasma source operating at frequencies of 2, 4, and 13.56 MHz and a power of 100–500 W are presented. The experiments were carried out in argon at pressures of 0.1–30 mTorr. The presence of the external magnetic field leads to the appearance of resonance domains of efficient RF power absorption corresponding to the conditions of resonance excitation of helicons coupled with Trivelpiece–Gould modes. It is shown that RF power absorption at frequencies of 2 MHz can be optimized by applying an external magnetic field corresponding to the domains of resonance absorption. The effect is enhanced with increasing operating frequency.  相似文献   

18.
杀虫剂抗性: 遗传学、基因组学及应用启示   总被引:6,自引:1,他引:6  
邱星辉 《昆虫学报》2005,48(6):960-967
杀虫剂抗性已成为害虫防治工作需要解决的一个重要问题,也是一种人为的、自然选择的重要的进化现象,开展抗药性的研究不仅为抗性的监测、治理和农药工业的发展提供科学参考,还可以揭示生物进化的一些基本规律。在过去的10年,昆虫对许多化学杀虫剂抗药性的分子基础得到了进一步阐明,已从果蝇Drosophila melanogaster中克隆了杀虫剂的靶标基因,还查明了一些害虫的与抗性相关联的基因突变。最近,随着经注释的昆虫基因组的出现,由复杂多基因酶系如酯酶、细胞色素P450酶及谷胱甘肽S-转移酶介导的抗性的机制有了突破性的进展,有关杀虫剂抗性的进化以及抗性基因的传播模式也逐步得到揭示。基因组技术在揭示昆虫其他可能的抗药性机制以及在发现新的杀虫剂靶标方面将发挥更大的作用。  相似文献   

19.
The efficient coordination of agonist and antagonist muscles is one of the important early adaptations in resistance training responsible for large increases in strength. Weak antagonist muscles may limit speed of movement; consequently, strengthening them leads to an increase in agonist muscle movement speed. However, the effect of combining agonist and antagonist muscle exercises into a power training session has been largely unexplored. The purpose of this study was to determine if a training complex consisting of contrasting agonist and antagonist muscle exercises would result in an acute increase in power output in the agonist power exercise. Twenty-four college-aged rugby league players who were experienced in combined strength and power training served as subjects for this study. They were equally assigned to an experimental (Antag) or control (Con) group and were no different in age, height, body mass, strength, or maximal power. Power output was assessed during bench press throws with a 40-kg resistance (BT P40) with the Plyometric Power System training device. After warming up, the Con group performed the BT P40 tests 3 minutes apart to determine if any acute augmentation to power output could occur without intervention. The Antag group also performed the BT P40 tests; however, an intervention strategy of a set of bench pulls, which is an antagonistic action to the bench throw, was performed between tests to determine if this would acutely affect power output during the second BT P40 test. Although the power output for the Con group remained unaltered between test occasions, the significant 4.7% increase for the Antag group indicates that a strategy of alternating agonist and antagonist muscle exercises may acutely increase power output during complex power training. This result may affect power training and specific warm-up strategies used in ballistic sports activities, with increased emphasis placed upon the antagonist muscle groups.  相似文献   

20.
《Process Biochemistry》2010,45(6):929-934
The aim of this study is to compare the performance of different membrane cathode assembly (MCA) and cloth-cathode assembly (CCA) in air-chamber microbial fuel cells (MFCs) and provide an optimum cathode configuration for MFC scaling up. Two MCAs were prepared by hot-pressing carbon cloth containing cathodic catalyst to anion exchange membrane (AEM) and cation exchange membrane (CEM), respectively. A CCA was built by coating GORE-TEX® cloth with a mixture of nickel-based conductive paint and cathodic catalyst. Under the fed-batch mode using brewery wastewater, the MFCs were compared with respect to power production, coulombic efficiency, COD removal, internal resistance and material cost. The experimental results show that CCA is a more favorable alternative than MCAs due to its easier preparation, higher maximum power density and COD removal, and lower internal resistance and cost. The optimum cathode assembly of CCA is cost-effective and mechanically robust enough to meet the important requirements for MFC scalability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号