首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PurposeTo evaluate the opportunities of single photon emission tomography/computerized tomography (SPECT-CT) for localization of axillary sentinel lymph nodes (ASLNs) and subsequent radiotherapy planning in women with early breast cancer.Material and methodsIndividual topography of ASLN was determined in 151 women with clinical T1-2N0M0 breast cancer. SPECT-CT visualization of ASLNs was initiated 120 min after intra-peritumoral injection of 99mTc-radiocolloids. Doses absorbed by virtual ASLNs after the whole breast irradiation with standard and extended tangential fields were calculated on a treatment planning station.ResultsSPECT-CT demonstrated a large variability of ASLN localization. They were detected in the central subgroup in 94 (61%) patients, in pectoral – in 77 (51%), and in interpectoral – in 4 (3%) patients. Sentinel lymph nodes “lying on the chest” were revealed in 35 (23%) cases.We found that with standard tangential fields coverage of ASLNs was obtained only in 20% of evaluated women. Extended tangential fields can effectively irradiate ASLNs localized in all axillary sub-regions with the exception of ASLNs “lying on the chest”.ConclusionSPECT-CT mapping of ASLNs in women with cT1-2N0M0 breast cancer reveals their variable localization. This information can be important for planning of radiation treatment in women that underwent breast conserving surgery without an axillary surgery.  相似文献   

2.
BackgroundBreast cancer patients with positive sentinel lymph node biopsy (SLNB) may be spared axillary lymph node dissection (ALND) in favour of irradiation. The aim of the study was to estimate local control probability in the axilla (axLCP).Materials and methodsWe identified 1832 invasive breast cancer patients who had undergone SLNB at our centre. We measured maximal metastasis diameter (SLDmax) in the sentinel lymph nodes and lymph node metastasis volume (VALN) from ALND in 246 patients with one or two positive SLNs. We calculated axLCP after irradiation and systemic treatment for different molecular types.ResultsVALN values are higher for high grade tumours and larger metastases in SLNs (> 5 mm). It is smaller in luminal A tumours. axLCP is high, nearly 100%, in all molecular types in radiation sensitive tumours (SF2 Gy = 0.45), except luminal B. Expected axLCP is relatively low (67%) in luminal B radiation sensitive tumours with no chemotherapy and nearly 100% with chemotherapy.ConclusionVALN values differ among molecular tumour types. They depend on SLNDmax and tumour grade. New prognostic factors are needed for selected luminal B breast cancer patients (i.e. high grade tumours, large metastases in SLNs) after positive SLNB intended to be spared ALND and chemotherapy.  相似文献   

3.
4.
The sentinel lymph node (SLN) is considered to be the first axillary node that contains malignant cells in metastatic breast tumors, and its positivity is currently used in clinical practice as an indication for axillary lymph node dissection. Therefore, accurate evaluation of the SLN for the presence of breast metastatic cells is essential. The main aim of our study is to characterize the genomic changes present in the SLN metastatic samples with the ultimate goal of improving the predictive value of SLN evaluation. Twenty paired samples of SLN metastases and their corresponding primary breast tumors (PBT) were investigated for DNA copy number changes using comparative genomic hybridization (CGH). Non-random DNA copy number changes were observed in all the lesions analyzed, with gains being more common than losses. In 75% of the cases there was at least one change common to both PBT and SLN. The most frequent changes detected in both lesions were gains of 1pter-->p32, 16, 17, 19, and 20 and losses of 6q13-->q23 and 13q13-->q32. In the PBT group, alterations on chromosomes 1, 16, and 20 were the most frequent, whereas chromosomes 1, 6, and 19 were the ones with the highest number of changes in the SLN metastatic group. A positive correlation was found between the DNA copy number changes per chromosome in each of the groups. Our findings indicate the presence of significant DNA copy number changes in the SLN metastatic lesions that could be used in the future as additional markers to improve the predictive value of SLN biopsy procedure.  相似文献   

5.
For patients with invasive breast cancer, if the results of an axillary sentinel node biopsy are determined to be positive after permanent pathologic examination, the current recommendation is to perform a complete axillary node dissection. Subsequent axillary surgery may compromise the blood supply to an immediate autologous breast reconstruction. The purpose of this study was to determine which clinicopathologic factors in clinically node-negative breast cancer patients may be associated with an increased risk of positive axillary nodes. Identification of these factors will allow surgeons to modify their approach to immediate autologous breast reconstruction in these high-risk patients. The relationship between presenting clinicopathologic characteristics and the incidence of axillary metastases was analyzed by chi-square test and multivariate analysis in 167 patients with invasive breast cancer and a clinically negative axilla who underwent modified radical mastectomy with an immediate free transverse rectus abdominis musculocutaneous (TRAM) flap reconstruction. Axillary nodal metastases were found in 35 percent of clinically node-negative breast cancer patients. Multivariate analysis showed that patient age of 50 years or younger (p = 0.019), T2 tumor stage or greater (p = 0.031), and presence of lymphovascular invasion on the initial biopsy specimen (p < 0.001) were independent predictors of axillary metastases in clinically node-negative patients. Based on these results, the authors propose an algorithm for decision making in clinically node-negative breast cancer patients who desire autologous breast reconstruction and sentinel lymph node biopsy. Options for immediate autologous breast reconstruction in patients undergoing mastectomy and axillary sentinel lymph node biopsy that may minimize the risk of vascular damage on reoperation include the use of the internal mammary artery and vein as recipient vessels for a free TRAM flap or a pedicled TRAM flap. If an axillary-based blood supply is used, the authors are considering the use of cadaveric dermis to isolate the pedicle of the flap away from the remaining axillary contents. New developments in breast cancer diagnosis and treatment necessitate a team approach, with increased communication between the breast surgeon and the plastic surgeon in planning surgery for these patients.  相似文献   

6.
摘要 目的:探究对初诊腋窝淋巴结阳性乳腺癌行新辅助化疗患者开展腋窝前哨淋巴结活检的临床意义。方法:选择2017年1月至2020年10月于我院接受改良根治术或保乳术治疗的100例初诊腋窝淋巴结阳性乳腺癌患者,将其中50例病理检测II B、III期行4~8个疗程新辅助化疗后实施前哨淋巴结活检患者设为研究组,将50例I、II A期直接行前哨淋巴结活检患者设为对照组,对比两组患者前哨淋巴结检出率、准确率、假阴性率和灵敏度,同时就患者病理特征与前哨淋巴结检出率的相关性开展分析。结果:(1)比较显示研究组患者与对照组患者在前哨淋巴结检出数、前哨淋巴结检出率以及前哨淋巴结假阴性率方面组间差异不大(P>0.05);(2)病理学特征分析显示肿瘤直径以及临床N分期同新辅助化疗后患者前哨淋巴结检出阳性率密切相关(P<0.05)。结论:对初诊腋窝淋巴结阳性行新辅助化疗乳腺癌患者实施前哨淋巴结活检具有较显示的临床意义,能够较好的预测患者腋窝淋巴结状况,同时化疗前肿瘤直径、临床N分期是影响前哨淋巴结检出率的重要影响因素。  相似文献   

7.
PurposeTo investigate different volumetric modulated arc therapy (VMAT) field designs for lymph node positive breast cancer patients when compared to conventional static fields and standard VMAT designs.MethodsNineteen breast cancer patients with lymph node involvement (eleven left and eight right sided) were retrospectively analyzed with different arc designs. Proposed split arc designs with total rotations of 2 × 190° and 2 × 240° were compared to conventional field in field (FinF) and previously published non-split arc techniques with the same amount of total rotations.ResultsAll VMAT plans were superior in dose conformity, when compared to the FinF plans. Split arc design decreased significantly ipsilateral lung dose and heart V5Gy for both left and right sided cases, when compared to non-split VMAT designs. For left sided cases no significant differences were seen in contralateral lung mean dose or V5Gy between different VMAT designs. For right sided cases the contralateral lung dose V5Gy was significantly higher in split VMAT group, when compared to non-split VMAT designs. The contralateral breast dose V5Gy increased significantly for split VMAT plans for both sides, when compared to non-split VMAT designs or FinF plans.ConclusionsThe proposed split VMAT technique was shown to be superior to previously published non-split VMAT and conventional FinF techniques significantly reducing dose to the ipsilateral lung and heart. However, this came with the expense of an increase in the dose to the contralateral breast and for right-sided cases to the contralateral lung.  相似文献   

8.
OBJECTIVE: Sentinel lymph node (SLN) biopsy is a new component of the surgical treatment of breast cancer that accurately predicts axillary status. In this study the authors evaluated the accuracy of intraoperative imprint cytology (IC) in comparison with definitive histologic evaluation of SLN in breast cancer patients. METHODS: A total 413 women with breast carcinoma and clinically negative axillary nodes underwent breast surgery and SLN biopsy. Mapping of SLN involved injection of (99m)Technecium labelled human albumin nanocolloid particles and Patent Blue dye. At the Department of Pathology, SLNs were bisected along its major axis. Both halves were imprinted 2-4 times on the slides and immediate staining with Hemacolor (Merck Germany) was performed for intraoperative examination. Imprint node negative women underwent no further surgery, while node positive women proceeded to full axillary clearance. Histological analysis of the SLN involved serial sectioning of the whole node with H&E and immunostaining for cytokeratin. RESULTS: Definitive histology revealed metastases (pN+) in 159/413 patients (38.5%): 69 (16.7%) macro metastases, 57 (13.8%) micro metastases, and 33 (8%) women with only isolated IHC positive cells or positive cell groups smaller than 0.2 mm (pNO sn+). The other 254 women had negative SLN biopsy. Imprint cytology detected 54/69 macro metastases, and 4/57 micro metastases. In the group with negative SLN (254), 2 cases were 'false positives'. CONCLUSIONS: Imprint of SLN biopsy can identify a negative axilla with high accuracy (specificity 99.2%). Overall sensitivity is only 36.5%, but macrometastases are detected in 77% which is important for performing ALDN in one session with operation of primary tumour.  相似文献   

9.
Neoadjuvant treatment is often considered in breast cancer patients with axillary lymph node involvement, but most of patients do not have a pathologic complete response to therapy. The detection of residual nodal disease has a significant impact on adjuvant therapy recommendations which may improve survival. Here, we investigate whether multiphoton microscopy (MPM) could identify the pathological changes of axillary lymphatic metastasis after neoadjuvant chemotherapy in breast cancer. And furthermore, we find that there are obvious differences in seven collagen morphological features between normal node and residual axillary disease by combining with a semi-automatic image processing method, and also find that there are significant differences in four collagen features between the effective and no-response treatment groups. These research results indicate that MPM may help estimate axillary treatment response in the neoadjuvant setting and thereby tailor more appropriate and personalized adjuvant treatments for breast cancer patients.  相似文献   

10.
OBJECTIVE: To compare imprint cytology with histology as a method for rapid intraoperative diagnosis of axillary lymph node metastasis in breast cancer. STUDY DESIGN: We evaluated imprint cytology, comparing it with histopathology. A sample of 635 axillary lymph nodes was studied by imprint cytology using both Giemsa stain and hematoxylin-eosin. The results were compared with each other and with those of histopathologic examination. RESULTS: The Giemsa stain method, as compared to histopathology, had 94% accuracy, 97% sensitivity, 90% specificity and 94% positive prognostic value. The hematoxylin-eosin stain method was less accurate than the Giemsa stain method as compared to histopathology (accuracy 91%, sensitivity 96%, specificity 83% and positive prognostic value 92%). CONCLUSION: These data confirm the value of imprint cytology as a rapid, reliable method of intraoperative assessment of axillary lymph node metastasis in breast cancer. It results in better staging of the disease. It can be used intraoperatively, as an alternative to frozen section, if a pathology laboratory is not available, to exclude stage I patients from further treatment.  相似文献   

11.
ObjectivePreoperative lymphoscintigraphy (PLS) combined with intraoperative gamma probe (GP) localization is standard procedure for localizing the sentinel lymph nodes (SLN) in melanoma and breast cancer. In this study, we evaluated the ability of a novel intraoperative handheld gamma camera (IHGC) to image SLNs during surgery.MethodsThe IHGC is a small-field-of-view camera optimized for real-time imaging of lymphatic drainage patterns. Unlike conventional cameras, the IHGC can acquire useful images in a few seconds in a free-running fashion and be moved manually around the patient to find a suitable view of the node. Thirty-nine melanoma and eleven breast cancer patients underwent a modified SLN biopsy protocol in which nodes localized with the GP were imaged with the IHGC. The IHGC was also used to localize additional nodes that could not be found with the GP.ResultsThe removal of 104 radioactive SLNs was confirmed ex vivo by GP counting. In vivo, the relative node detection sensitivity was 88.5 (82.3, 94.6)% for the IHGC (used in conjunction with the GP) and 94.2 (89.7, 98.7)% for the GP alone, a difference not found to be statistically significant (McNemar test, p = 0.24).ConclusionSmall radioactive SLNs can be visualized intraoperatively using the IHGC with exposure time of 20 s or less, with no significant difference in node detection sensitivity compared to a GP. The IHGC is a useful complement to the GP, especially for SLNs that are difficult to locate with the GP alone.  相似文献   

12.
13.

Aims

This paper describes a simple technique of axillary and breast massage which improves the successful identification of blue sentinel nodes using patent blue dye alone.

Methods

Patent blue dye was injected in the subdermal part of the retroaroelar area in 167 patients having surgical treatment for invasive breast cancer. Three stage axillary lymphatic massage was performed prior to making the axillary incision for sentinel lymph node biopsy. All patients had completion axillary sampling or clearance.

Results

A blue lymphatic duct leading to lymph nodes of the first drainage was identified in 163 (97%) of the patients. Results are compared with 168 patients who had sentinel lymph node biopsy using blue dye without axillary massage. Allergic reactions were observed in four patients (1.2%).

Conclusion

Three stage axillary lymphatic massage improves the successful identification of a blue sentinel lymph node in breast cancer patients.
  相似文献   

14.
PurposeTo investigate the use of dual isocenters for VMAT planning in patients with lymph node positive synchronous bilateral breast cancer (BBC) compared to a single isocenter option.MethodsTreatment plans of 11 patients with lymph node positive BBC were retrospectively analyzed using two different VMAT planning techniques: dual-isocenter split-arc VMAT plans (Iso2) were compared with mono-isocenter VMAT plans (Iso1). For Iso2 plans, PTV dose was investigated after introducing ±2 and ±5 mm couch shift errors between the two isocenters in the lateral, longitudinal and vertical direction.ResultsFor both techniques the planning aims for PTV coverage and OARs were met. The mean dose for the bilateral lungs and heart was reduced from 11.3 Gy and 3.8 Gy to 10.9 Gy (p < .05) and 3.6 Gy (p < .05), respectively, for Iso2 plans when compared to Iso1 plans. Positive statistically significant correlation (rho = 0.76, p = .006) was found between PTV volume and D2ccPTV for Iso1 plans. No clinically significant change was seen in the D98CTV or D2ccPTV after the 2 and 5 mm errors were introduced between isocenters for Iso2 plans.ConclusionsThe split arc method was shown to be a feasible treatment technique in the case of synchronous BBC for both mono and dual isocenter techniques. The dose parameters were slightly favoring dual-isocenter option instead of mono-isocenter. The dual-isocenter method was shown to be a robust treatment option in the presence of ≤5 mm errors in the shifts between the two isocenters.  相似文献   

15.
16.
The concept of the sentinel node describes a primary or sentinel lymph node (SLN), which exists and through which tumour cells from a primary tumour in a particular location must first travel to spread to a particular regional lymph node group. In this series we present three patients presenting with a pathological axillary node associated with either an occult or very small primary breast cancer. In each case the primary tumour was found to have metastasised to the palpable node, however despite the significant enlargement of this node, no other axillary nodes were found to be affected on axillary node clearance. This has led us to postulate that the SLN in some cases contains unique characteristics that enable it to prevent further spread of the tumour up the lymphatic chain. Hence the term the competent sentinel node.  相似文献   

17.
A 58 year old lady presented with a right breast cancer and a prior history of malignant melanoma excised from the right chest wall eight years previously. An abnormal axillary lymph node resected contained features of both metastatic breast carcinoma and malignant melanoma. Following oncologic breast cancer management, the patient is well with no evidence of recurrence at three years.  相似文献   

18.
Abstract

The imaging of sentinel lymph nodes (SLN) has been researched for its role in assessing cancer progression and postsurgical lymphedema. Indocyanine green (ICG) is a near-infrared (NIR) optical dye that has been approved by the Food and Drug Administration. It is known that liposome-encapsulated ICG (LP-ICG) has improved stability and fluorescence signal compared with ICG. We designed mannosylated liposome-encapsulated ICG (M-LP-ICG) as an optical contrast agent for SLN. M-LP-ICG has a higher UV absorbance spectrum and fluorescence intensity than LP-ICG. The stability of M-LP-ICG measured in 50% fetal bovine serum solution by a dialysis method was better than that of LP-ICG. M-LP-ICG demonstrated a high uptake in RAW 264.7 macrophage cell because the density of mannose is high. There were differences between M-LP-ICG and glucosylated liposome-encapsulated ICG (G-LP-ICG), which are geometrical isomers. The result of an inhibition study of M-LP-ICG showed a statistically significant decrease in uptake in RAW 264.7 cells after either co-treatment or pre-treatment with d-(+)-mannose as an inhibitor. Results from an in vitro experiment demonstrated that M-LP-ICG was specifically taken up by macrophage cells through the mannose receptor on its surface. The time-series images acquired from a normal mouse model after subcutaneous injection showed that the signal from M-LP-ICG in SLN and other organs appeared early and disappeared quickly in comparison with signals from LP-ICG. Not only the sentinel but also the draining lymph nodes were observed partly in M-LP-ICG. M-LP-ICG appears to increase the specificity of uptake and retention in macrophages, making it a good candidate contrast agent for an optic imaging system for SLN and the lymphatic system.  相似文献   

19.
BackgroundThe aim of our study is to determine whether deep inspiration breath hold (DIBH) is effective for reducing exposure of the heart, left coronary artery (LAD) and both lungs in right breast radiotherapy.Materials and methodsWe have analyzed 10 consecutive patients with right-sided breast cancer (BC), simulated during free breathing (FB) and in DIBH modality. For all patients we contoured breast PTV and organs at risk (right and left lungs, heart, LAD) on both CT scans (FB and DIBH). Finally, 5 patients were treated with IMRT and 5 with VMAT techniques.ResultsAll patients were able to end the treatments in DIBH modalities regardless of the longer treatment time in comparison to FB. The maximum and mean dose to the heart are lower in the DIBH modality. The mean values of the heart mean dose were 1.76 Gy in DIBH and 2.19 Gy in FB. The mean heart maximum dose in DIBH and FB were, respectively, 9.3 Gy and 11 Gy. Likewise, the maximum dose to the LAD is lower in DIBH; 2.57 Gy versus 3.56 Gy in FB. Noteworthy, 3 patients with hepatomegaly treated with the DIBH technique showed a higher ipsilateral lung dose than FB, but a decrease of liver dose.ConclusionWe report that the use of DIBH for right-sided BC allows the dose to the heart, LAD and to the liver to be reduced in case of hepatomegaly. This technique is well tolerated by patients, when adequately trained, and could be considered effective even in right sided BC.  相似文献   

20.
目的:研究高频彩色多普勒超声对乳腺癌腋窝良性淋巴结与腋窝转移性淋巴结的鉴别价值。方法:选择2015年2月~2016年6月在我院进行诊治的乳腺癌患者150例,应用高频二维超声结合彩色多普勒血流显像技术,观察腋窝肿大淋巴结的声像图及血流情况。结果:经二维超声发现,乳腺癌腋窝良性淋巴结的皮质多向心增厚(68.93%)、长短径比L/S多2.0(70.58%)、多不融合(93.14%)、多无钙化斑(97.06%);腋窝转移性淋巴结的皮质多偏心增厚(68.48%)、长短径比L/S多2.0(69.57%)、多融合(68.48%)、多有钙化斑(77.17%);两者相比有明显差异(P0.05);经彩色多普勒血流显像技术发现,乳腺癌腋窝良性淋巴结的血流信号分布多呈门型(63.17%),血流丰富程度多为Ⅱ级(54.35%);腋窝转移性淋巴结的血流信号分布多呈周边型(68.93%),血流丰富程度多为Ⅲ级(72.83%);两者相比有明显差异(P0.05)。结论:乳腺癌腋窝良性淋巴结与腋窝转移性淋巴结在内部回声、形态、血流分布特点等方面有显著的差异,高频彩色多普勒超声对乳腺癌腋窝良性淋巴结与腋窝转移性淋巴结具有较高的鉴别价值。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号