首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Aim

To evaluate the clinical outcome and toxicity of the treatment of muscle-invasive bladder cancer (MIBC) that combined transurethral resection of bladder tumor (TURB) with “concomitant boost” radiotherapy delivered over a shortened overall treatment time of 5 weeks, with or without concurrent chemotherapy.

Background

Local control of MIBC by bladder-sparing approach is unsatisfactory. In order to improve the effectiveness of radiotherapy, we have designed a protocol that combines TURB with a non-conventionally fractionated radiotherapy “concomitant boost”.

Materials and methods

Between 2004 and 2010, 73 patients with MIBC cT2-4aN0M0, were treated with “concomitant boost” radiotherapy. The whole bladder with a 2–3 cm margin was irradiated with fractions of 1.8 Gy to a dose of 45 Gy, with a “concomitant boost” to the bladder with 1–1.5 cm margin, during the last two weeks of treatment, as a second fraction of 1.5 Gy, to a total dose of 60 Gy. Radiochemotherapy using mostly cisplatin was delivered in 42/73(58%) patients, 31/73(42%) patients received radiotherapy alone.

Results

Acute genitourinary toxicity of G3 was scored in 3/73(4%) patients. Late gastrointestinal toxicity higher than G2 and genitourinary higher than G3 were not reported. Complete remission was achieved in 48/73(66%), partial remission in 17/73(23%), and stabilization disease in 8/73(11%) patients. Three- and five-year overall, disease specific and invasive locoregional disease-free survival rates were 65% and 52%, 70% and 59%, 52% and 43%, respectively.

Conclusions

An organ-sparing approach using TURB followed by radio(chemo)therapy with “concomitant boost” in patients with MIBC allows to obtain long-term survival with acceptable toxicity.  相似文献   

2.

Aim

To compare and evaluate the performance of two different volumetric modulated arc therapy delivery techniques.

Background

Volumetric modulated arc therapy is a novel technique that has recently been made available for clinical use. Planning and dosimetric comparison study was done for Elekta VMAT and Varian RapidArc for different treatment sites.

Materials and methods

Ten patients were selected for the planning comparison study. This includes 2 head and neck, 2 oesophagus, 1 bladder, 3 cervix and 2 rectum cases. Total dose of 50 Gy was given for all the plans. All plans were done for RapidArc using Eclipse and for Elekta VMAT with Monaco treatment planning system. All plans were generated with 6 MV X-rays for both RapidArc and Elekta VMAT. Plans were evaluated based on the ability to meet the dose volume histogram, dose homogeneity index, radiation conformity index, estimated radiation delivery time, integral dose and monitor units needed to deliver the prescribed dose.

Results

RapidArc plans achieved the best conformity (CI95% = 1.08 ± 0.07) while Elekta VMAT plans were slightly inferior (CI95% = 1.10 ± 0.05). The in-homogeneity in the PTV was highest with Elekta VMAT with HI equal to 0.12 ± 0.02 Gy when compared to RapidArc with 0.08 ± 0.03. Significant changes were observed between the RapidArc and Elekta VMAT plans in terms of the healthy tissue mean dose and integral dose. Elekta VMAT plans show a reduction in the healthy tissue mean dose (6.92 ± 2.90) Gy when compared to RapidArc (7.83 ± 3.31) Gy. The integral dose is found to be inferior with Elekta VMAT (11.50 ± 6.49) × 104 Gy cm3 when compared to RapidArc (13.11 ± 7.52) × 104 Gy cm3. Both Varian RapidArc and Elekta VMAT respected the planning objective for all organs at risk. Gamma analysis result for the pre-treatment quality assurance shows good agreement between the planned and delivered fluence for 3 mm DTA, 3% DD for all the evaluated points inside the PTV, for both VMAT and RapidArc techniques.

Conclusion

The study concludes that a variable gantry speed with variable dose rate is important for efficient arc therapy delivery. RapidArc presents a slight improvement in the OAR sparing with better target coverage when compared to Elekta VMAT. Trivial differences were noted in all the plans for organ at risk but the two techniques provided satisfactory conformal avoidance and conformation.  相似文献   

3.
BackgroundThe purpose of this study was to evaluate dosimetric and radiobiological difference between volumetric modulated arc therapy (VMAT) and 3-dimensional conformal radiotherapy (3DCRT) in organ at risk (OAR) lumbosacral plexus (LSP) in cervical cancer patients.Materials and methods30 patients of cervical cancer who were treated using 3DCRT or VMAT along with chemotherapy followed by brachytherapy were enrolled. LSP was delineated retrospectively. Dosimetric and radiobiological difference was evaluated. Patients were followed for radiation induced lumbosacral plexopathy (RILSP).ResultsMedian follow-up was 12 months (3–16 months). 53.3% of patients were treated by 3DCRT and 46.7% by VMAT. The mean (±SD) LSP volume: 119.03 ± 15 cm3. The mean volume percentages (%) of the LSP: V5, V10, V20, V30, V40, V50, V55, and V60 were 100%, 99.8%, 99.2%, 94.3%, 84.03%, 59.7%, 0%, 0%, respectively. All patients received doses to the LSP in excess of 50 Gy, one patient received 55 Gy. A statistically significant difference was observed in the median value of V20, V30, V40, V50, D50, P2, P4, P7, P8, P9, and P10 across two different techniques of radiotherapy — VMAT and 3DCRT. None of the patients presented with RILSP. NTCP value was less in VMAT plans compared to 3DCRT, which is also statistically significant.ConclusionRILSP is a rare and often refractory complication of pelvic radiotherapy. Advance radiotherapy technique with proper OAR delineation and constraint can prevent the occurrence of RILSP. VMAT has potential benefits for the probability of dose reduction in LSP. Further studies are required focusing on dose distribution in LSP–OAR and radiotherapy modality.  相似文献   

4.
Objectives To test the hypotheses that, compared with conventional outpatient consultations, joint teleconsultation (virtual outreach) would incur no increased costs to the NHS, reduce costs to patients, and reduce absences from work by patients and their carers.Design Cost consequences study alongside randomised controlled trial.Setting Two hospitals in London and Shrewsbury and 29 general practices in inner London and Wales.Participants 3170 patients identified; 2094 eligible for inclusion and willing to participate. 1051 randomised to virtual outreach and 1043 to standard outpatient appointments.Main outcome measures NHS costs, patient costs, health status (SF-12), time spent attending index consultation, patient satisfaction.Results Overall six months costs were greater for the virtual outreach consultations (£724 per patient) than for conventional outpatient appointments (£625): difference in means £99 ($162; €138) (95% confidence interval £10 to £187, P=0.03). If the analysis is restricted to resource items deemed “attributable” to the index consultation, six month costs were still greater for virtual outreach: difference in means £108 (£73 to £142, P < 0.0001). In both analyses the index consultation accounted for the excess cost. Savings to patients in terms of costs and time occurred in both centres: difference in mean total patient cost £8 (£5 to £10, P < 0.0001). Loss of productive time was less in the virtual outreach group: difference in mean cost £11 (£10 to £12, P < 0.0001).Conclusion The main hypothesis that virtual outreach would be cost neutral is rejected, but the hypotheses that costs to patients and losses in productivity would be lower are supported.  相似文献   

5.
BackgroundDiet is an important factor in the prevention of chronic diseases. Analysis of secular trends of dietary patterns can be biased by energy under-reporting. Therefore, the objective of the present study was to analyse the impact of energy under-reporting on dietary patterns and secular trends in dietary patterns defined by cluster analysis.ResultsThree clusters, “healthy”, “mixed” and “western”, were identified for both surveys. The “mixed” cluster was the predominant cluster in both surveys. Excluding EUR reduced the proportion of the “mixed” cluster up to 6.40% in the 2000 survey; this caused secular trend increase in the prevalence of the “mixed” pattern. Cross-classification analysis of all participants and PER’ data showed substantial agreement in cluster assignments: 68.7% in 2000 and 84.4% in 2005. Excluding EUR did not cause meaningful (≥15%) changes in the “healthy” pattern. It provoked changes in consumption of some food groups in the “mixed” and “western” patterns: mainly decreases of unhealthy foods within the 2000 and increases of unhealthy foods within the 2005 surveys. Secular trend effects of EUR were similar to those within the 2005 survey. Excluding EUR reversed the direction of secular trends in consumption of several food groups in PER in the “mixed” and “western” patterns.ConclusionsEUR affected distribution of participants between dietary patterns within and between surveys, secular trends in food group consumption and amount of food consumed in all, but not in the “healthy” pattern. Our findings emphasize threats from energy under-reporting in dietary data analysis.  相似文献   

6.
BackgroundThe purpose of the study was to evaluate the toxicity and outcome of nasopharyngeal carcinoma patients treated using 3-dimensional conformal radiotherapy (3DCRT) or volumetric modulated arc therapy (VMAT) technique.Materials and methods68 patients treated between 2006 and 2018 were retrospectively analysed. Since 2009 patients received 3DCRT with 50/70 Gy to the elective/boost volumes in 35 fractions; from then, VMAT with simultaneous integrated boost (SIB) with 54.45/69.96 Gy in 33, or 54/66 Gy in 30 fractions. Induction chemotherapy was administered in 74% of the patients, concomitant cisplatinum in 87%. Acute and late toxicity data, progression-free survival PSF and overall survival OS, and toxicity correlations with dose metrics were reported.ResultsWith a median follow-up of 64 months, complete remission at the last evaluation was in 68% of the patients, while 28% and 9% had locoregional relapse and distant disease, respectively. The 5- and 10-year progression free survival (PFS) rates were 62.7 ± 6.5% and 53.2 ± 8.7%, respectively. The 5- and 10-year OS rates were 78.9 ± 5.5% and 61.4 ± 9.2%, respectively. At the multivariate Cox analysis TNM stage (p = 0.02) and concomitant chemotherapy (p = 0.01) resulted significant for PFS, concomitant chemotherapy (p = 0.04) for OS.Improvements in acute toxicity were presented for VMAT patients due to its ability to spare OARs. Odds ratio (OR) for acute salivary toxicity, between VMAT and 3DCRT, was 4.67 (p = 0.02). Dosimetrically, salivary toxicity correlated with mean parotid dose (p = 0.05), dysphagia with laryngeal (p = 0.04) and mean oral cavity (p = 0.06) doses, when dose-volume histograms (DVHs) are corrected for fractionation.ConclusionThis study is a proof of a significant benefit of the VMAT technique compared with 3DCRT in terms of side effects in nasopharynx patients, and adds dosimetric correlations.  相似文献   

7.
BackgroundThe dosimetric characterization of volumetric modulated arc therapy (VMAT)-based total-body irradiation (TBI) in pediatric patients is evaluated.Materials and methodsTwenty-two patients between the ages of 2 and 12 years were enrolled for VMAT-based TBI from 2018 to 2020. Three isocenters were irradiated over three overlapping arcs. While prescribing 90% of the TBI dose to the planning treatment volume (PTV), two fractions (2 Gy each) were delivered each day; hence 12 Gy was delivered in six fractions. During treatment optimization, the mean lung and kidney doses were set not to exceed 7 Gy and 7.5 Gy, respectively. The maximum lens dose was also set to less than 4 Gy. Patient quality assurance was carried out by comparing treatment planning system doses to the 3-dimensional measured doses by the ArcCHECK® detector. The electronic portal imaging device (EPID) gamma indices were also obtained.ResultsThe average mean lung dose was 7.75 ± 0.18 Gy, mean kidney dose 7.63 ± 0.26 Gy, maximum lens dose 4.41 ± 0.39 Gy, and the mean PTV dose 12.69 ± 0.16 Gy. The average PTV heterogeneity index was 1.15 ± 0.03. Average differences in mean kidney dose, mean lung dose, and mean target dose were 2.79% ± 0.88, 0.84% ± 0.45 and 0.93% ± 0.47, respectively; when comparing planned and ArcCHECK® measured doses. Only grade 1–2 radiation toxicities were recorded, based on CTCAE v5.0 scoring criteria.ConclusionsVMAT-TBI was characterized with good PTV coverage, homogeneous dose distribution, planned and measured dose agreement, and low toxicity.  相似文献   

8.

Purpose

To examine the frequency and potential of dose-volume predictors for chest wall (CW) toxicity (pain and/or rib fracture) for patients receiving lung stereotactic body radiotherapy (SBRT) using treatment planning methods to minimize CW dose and a risk-adapted fractionation scheme.

Methods

We reviewed data from 72 treatment plans, from 69 lung SBRT patients with at least one year of follow-up or CW toxicity, who were treated at our center between 2010 and 2013. Treatment plans were optimized to reduce CW dose and patients received a risk-adapted fractionation of 18 Gy×3 fractions (54 Gy total) if the CW V30 was less than 30 mL or 10–12 Gy×5 fractions (50–60 Gy total) otherwise. The association between CW toxicity and patient characteristics, treatment parameters and dose metrics, including biologically equivalent dose, were analyzed using logistic regression.

Results

With a median follow-up of 20 months, 6 (8.3%) patients developed CW pain including three (4.2%) grade 1, two (2.8%) grade 2 and one (1.4%) grade 3. Five (6.9%) patients developed rib fractures, one of which was symptomatic. No significant associations between CW toxicity and patient and dosimetric variables were identified on univariate nor multivariate analysis.

Conclusions

Optimization of treatment plans to reduce CW dose and a risk-adapted fractionation strategy of three or five fractions based on the CW V30 resulted in a low incidence of CW toxicity. Under these conditions, none of the patient characteristics or dose metrics we examined appeared to be predictive of CW pain.  相似文献   

9.

Aim

The purpose of this study was to evaluate acute and late toxicity and the locoregional control in patients treated with hypofractionated radical radiotherapy 2.25 Gy/fraction/day for early glottic carcinoma.

Materials and methods

A retrospective analysis was performed of 27 patients, stage T1–T2 N0 glottic squamous cell carcinoma, that underwent radical RT from April 2008 to October 2011. The mean age was 64.6 years (range 36–81). Seventeen patients were staged T1a, 3 patients T1b and 7 patients T2. All patients were 3D planned and treated in a 6 MV LINAC, 2.25 Gy/fraction/5 days per week, to a total dose between 63 Gy and 67.5 Gy. Biological Effective Dose (BED (α/β = 10)) ranged from 77.18 Gy to 82.69 Gy and EQD2 from 64.31 Gy to 68.91 Gy. Patients were evaluated in periodic follow-up. Toxicity was evaluated according to RTOG Toxicities Scales.

Results

With a median follow-time of 24.7 months (range 3.6–44.2 months), no evidence of locoregional recurrence was observed. The treatment was well tolerated and no unscheduled interruptions in treatments for toxicity were documented, with the median overall treatment time of 41 days (range 38–48). Only grades 1 and 2 acute toxicity were observed and no evidence of severe late toxicity.

Conclusion

The authors believe that this moderately hypofractionated scheme can provide a good locoregional control for T1–T2 glottic carcinomas with no increase of toxicity. As the limitation of this work is the reduced number of patients and the lack of long term follow-up, the authors hope to update this retrospective study in the future in order to improve the power of the results.  相似文献   

10.
BackgroundMany U.S.-bound refugees travel from countries where intestinal parasites (hookworm, Trichuris trichuria, Ascaris lumbricoides, and Strongyloides stercoralis) are endemic. These infections are rare in the United States and may be underdiagnosed or misdiagnosed, leading to potentially serious consequences. This evaluation examined the costs and benefits of combinations of overseas presumptive treatment of parasitic diseases vs. domestic screening/treating vs. no program.MethodsAn economic decision tree model terminating in Markov processes was developed to estimate the cost and health impacts of four interventions on an annual cohort of 27,700 U.S.-bound Asian refugees: 1) “No Program,” 2) U.S. “Domestic Screening and Treatment,” 3) “Overseas Albendazole and Ivermectin” presumptive treatment, and 4) “Overseas Albendazole and Domestic Screening for Strongyloides”. Markov transition state models were used to estimate long-term effects of parasitic infections. Health outcome measures (four parasites) included outpatient cases, hospitalizations, deaths, life years, and quality-adjusted life years (QALYs).ResultsThe “No Program” option is the least expensive ($165,923 per cohort) and least effective option (145 outpatient cases, 4.0 hospitalizations, and 0.67 deaths discounted over a 60-year period for a one-year cohort). The “Overseas Albendazole and Ivermectin” option ($418,824) is less expensive than “Domestic Screening and Treatment” ($3,832,572) or “Overseas Albendazole and Domestic Screening for Strongyloides” ($2,182,483). According to the model outcomes, the most effective treatment option is “Overseas Albendazole and Ivermectin,” which reduces outpatient cases, deaths and hospitalization by around 80% at an estimated net cost of $458,718 per death averted, or $2,219/$24,036 per QALY/life year gained relative to “No Program”.DiscussionOverseas presumptive treatment for U.S.-bound refugees is a cost-effective intervention that is less expensive and at least as effective as domestic screening and treatment programs. The addition of ivermectin to albendazole reduces the prevalence of chronic strongyloidiasis and the probability of rare, but potentially fatal, disseminated strongyloidiasis.  相似文献   

11.
BackgroundA high-definition multi-leaf collimator (HD-MLC) with 5- and 10-mm fine MLCs is useful for radiotherapy. However, it is difficult to irradiate the mammary gland and supraclavicular region using a HD-MLC because of the narrow field of volumetric modulated arc radiotherapy (VMAT). Therefore, we aimed to evaluate the dose distribution of the VMAT dose using a HD-MLC in 15 patients with left breast cancer undergoing postoperative irradiation of breast and regional lymph nodes, including the internal mammary node.Materials and methodsThe following four plans were generated: three-arc VMAT using HD-MLC (HD-VMAT), two tangential arcs and one-arc VMAT using HD-MLC (tHD-VMAT), three-dimensional conformal radiotherapy (3DCRT) using HD-MLC, and two-arc VMAT using the Millennium 120-leaf MLC (M-VMAT). We assessed the doses to the target volume and organs at risk.ResultsThe target dose distributions were higher for HD-VMAT than 3DCRT. There were no significant differences in the heart mean dose (Dmean) or lung volume receiving 20 Gy (V20 Gy) between HD-VMAT and 3DCRT. The heart Dmean and lung V20 Gy of tHD-VMAT were higher than those of HD-VMAT, and the heart Dmean of M-VMAT was higher than that of HD-VMAT. However, the target doses of tHD-VMAT, M-VMAT, and HD-VMAT were equivalent.ConclusionsIn cases of the mammary gland and regional lymph node irradiation, including the internal mammary node in patients with left breast cancer, HD-VMAT was not inferior to M-VMAT and provided a better dose distribution to the target volume and organs at risk compared with 3DCRT and tHD-VMAT.  相似文献   

12.
BackgroundAccording to current recommendations, blood samples should be taken in the morning after 15 minutes’ resting time. Some components exhibit diurnal variation and in response to pressures to expand opening hours and reduce waiting time, the aims of this study were to investigate the impact of resting time prior to blood sampling and diurnal variation on biochemical components, including albumin, thyrotropin (TSH), total calcium and sodium in plasma.MethodsAll patients referred to an outpatient clinic for blood sampling were included in the period Nov 2011 until June 2014 (opening hours: 7am–3pm). Each patient’s arrival time and time of blood sampling were registered. The impact of resting time and the time of day for all components was analysed using simple linear regression. The “maximum allowable bias” was used as quality indicator for the change in reference interval.ResultsSignificant diurnal variation was found for albumin (n = 15,544; p<2×10−16), TSH (n = 20,019; p<2×10−16), calcium (n = 13,588; p = 2.8×10−12) and sodium (n = 51,917; p<2×10−16). Further significant influence for resting time was found for albumin (p = 2.6×10−4), TSH (p = 0.004), calcium (p = 8.9×10−7) and sodium (p = 8.7×10−16). Only TSH and albumin were clinically significantly influenced by diurnal variation. Resting time had no clinically significant effect.ConclusionsWe found no need for resting 15 minutes prior to blood sampling. However, diurnal variation was found to have a significant and considerable impact on TSH and, to a minor degree, albumin. This has to be taken into account to ensure that reference intervals provided by the laboratory are valid on a 24-hour basis.  相似文献   

13.
BackgroundThe aim of the study was to Estimate and compare the radiobiological ratio α/β with the heuristic method for a cohort of Mexican patients with prostate cancer (PCa) who were treated with external radiotherapy (RT) techniques at three Hospital Institutions in Mexico City. With the Kaplan-Meier technique and the Cox proportional hazards model, the biochemical relapse-free survival (bRFS) is determined and characterized for cohorts of Mexican patients with PCa who received treatment with external RT. Using these clinical outcomes, the radiobiological parameter α/β is determined using the heuristic methodology of Pedicini et. al.Materials and methodsThe α/β is calculated from the survival curves for different treatment schemes implemented at three distinct hospitals. The Pedicini’s techniques allow to determine the parameters α/β, k and N0 when treatments are not radiobiologically equivalent, therefore, are built up of a set of curved pairs for the biologically effective dose (BED) versus the ratio α/β, where the ratio is given by the intersection for each pair of curves.ResultsSix different values of α/β were found: the first α/β = 2.46 Gy, the second α/β = 3.30 Gy, the third for α/β = 3.25 Gy, the fourth α/β = 3.24 Gy, the fifth α/β = 3.38 Gy and the last α/β = 4.08 Gy. These values can be explained as follows: a) The bRFS of the schemes presents a statistical variation; b) The absorbed doses given to the patient present uncertainties on the physical dosimetry that are not on the modeling; c) Finally, in the model for the bRFS of Eq. (3), there are parameters that have to be considered, such as: the number of clonogenic tumor cells N0, the overall treatment time (OTT), the kick-off time for tumor repopulation Tk and the repopulation doubling time. Therefore, the mean value to α/β for all schemes has an average value of 3.29 (± 0.52) Gy.ConclusionsThe value of α/β¯=3.29(±0.52)Gy is determined from cohorts of Mexican patients with PC a treated with external radiotherapy using the time-dependent LQ model, which is a higher value with respect to the “dogma” value of α/β 1.5 Gy obtained with the LQ model without temporal dependence. Therefore, there is a possibility of optimizing treatments radiobiologically and improving the results of bRFS in Mexican patients with PCa treated with external radiotherapy.  相似文献   

14.
A combination of polymerase chain reaction-assisted rRNA sequence retrieval and fluorescent oligonucleotide probing was used to identify in situ a hitherto unculturable, big, magnetotactic, rod-shaped organism in freshwater sediment samples collected from Lake Chiemsee. Tentatively named “Magnetobacterium bavaricum,” this bacterium is evolutionarily distant from all other phylogenetically characterized magnetotactic bacteria and contains unusually high numbers of magnetosomes (up to 1,000 magnetosomes per cell). The spatial distribution in the sediment was studied, and up to 7 × 105 active cells per cm3 were found in the microaerobic zone. Considering its average volume (25.8 ± 4.1 μm3) and relative abundance (0.64 ± 0.17%), “M. bavaricum” may account for approximately 30% of the microbial biovolume and may therefore be a dominant fraction of the microbial community in this layer. Its microhabitat and its high content of sulfur globules and magnetosomes suggest that this organism has an iron-dependent way of energy conservation which depends on balanced gradients of oxygen and sulfide.  相似文献   

15.
Anaerobic ammonium-oxidizing (anammox) bacteria have been detected in many marine and freshwater ecosystems. However, little is known about the distribution, diversity, and abundance of anammox bacteria in terrestrial ecosystems. In this study, anammox bacteria were found to be present in various agricultural soils collected from 32 different locations in China. Phylogenetic analysis of the 16S rRNA genes showed “Candidatus Brocadia,” “Candidatus Kuenenia,” “Candidatus Anammoxoglobus,” and “Candidatus Jettenia” in the collected soils, with “Candidatus Brocadia” being the dominant genus. Quantitative PCR showed that the abundance of anammox bacteria ranged from 6.38 × 104 ± 0.42 × 104 to 3.69 × 106 ± 0.25 × 106 copies per gram of dry weight. Different levels of diversity, composition, and abundance of the anammox bacterial communities were observed, and redundancy analysis indicated that the soil organic content and the distribution of anammox communities were correlated in the soils examined. Furthermore, Pearson correlation analysis showed that the diversity of the anammox bacteria was positively correlated with the soil ammonium content and the organic content, while the anammox bacterial abundance was positively correlated with the soil ammonium content. These results demonstrate the broad distribution of diverse anammox bacteria and its correlation with the soil environmental conditions within an extensive range of Chinese agricultural soils.  相似文献   

16.

Background

Adjuvant radiotherapy (RTE) still has a fundamental role as a post-operative treatment of locally advanced soft tissues sarcomas of the extremities. Moreover the employment of combined modalities in locally advanced soft tissues sarcomas of the extremities allow to maximize the chance of local cure even in difficult presentation cases, and possibly improve survival, especially in high-risk disease patients. In patients with sarcomas of the extremities in which definitive surgery has not been radical (with positive or “close” margins) radiotherapy can improve the results in terms of Disease Free Survival (DFS) and, together with chemotherapy, of Overall Survival (OS). We recommend radiotherapy in case of deep tumor location, inadequate surgical margins and grade 3 tumour; for positive or “marginal (or close)” excision (that means inadequate surgery) or in selected patients with a bad prognosis, we believe that a multidisciplinary approach can be preferable.

Introduction

Adjuvant radiotherapy (RTE) still has a fundamental role as a post-operative treatment. In patients with sarcomas of the extremities in whom definitive surgery has been or not radical (positive or “close” margins), radiotherapy with chemotherapy can improve the results in terms of Disease Free Survival (DFS) and Overall Survival (OS), while RTE alone seems to improve local control.

Materials and methods

From 1/2000 to 12/2005 we treated 34 patients affected by locally advanced sarcomas of the upper or lower extremities with radiotherapy (doses ranging from 54 to 66 Gy) and chemotherapy in 18/34 with an adjuvant scheme that consisted in Epirubicine (120 mg/m2) plus Ifosfamide (7000–9000 mg/m2).

Results

Disease Free Survival (DFS) and the Overall Survival (OS) rates were 76% and 82%, respectively. Eighteen patients developed one or more long-term side effects. Most of these complications were mild: all patients experienced only erithema, edema, local sclerosis or moderate pain.

Conclusion

Radiotherapy has an important role as a post-operative treatment also when surgery was non-radical. It improves local control more in patients with high-grade sarcomas of the extremity with positive or close margins. It is still difficult to assess the role of adjuvant chemotherapy.  相似文献   

17.

Background

The most often found complications in patients with breast cancer who received radiotherapy are cardiac and pulmonary function disorders and development of second malignancies.

Aim

To compare the intensity modulated radiotherapy with the 3D tangential beams technique in respect of dose distribution in target volume and critical organs they generate in patients with early-stage breast cancer who received breast-conserving therapy.

Materials and methods

A dosimetric analysis was performed to assess the three radiotherapy techniques used in each of 10 consecutive patients with early-stage breast cancer treated with breast-conserving therapy. Radiotherapy was planned with the use of all the three techniques: 3D tangential beams with electron boost, IMRT with electron boost, and intensity modulated radiotherapy with simultaneous integrated boost.

Results

The use of the IMRT techniques enables more homogenous dose distribution in target volume. The range of mean and median dose to the heart and lung was lower with the IMRT techniques in comparison to the 3D tangential beams technique. The range of mean dose to the heart amounted to 0.3–3.5 Gy for the IMRT techniques and 0.4–4.3 for the tangential beams technique. The median dose to the lung on the irradiated side amounted to 4.9–5 Gy for the IMRT techniques and 5.6 Gy for the 3D tangential beams technique.

Conclusion

The application of the IMRT techniques in radiotherapy patients with early-stage breast cancer allows to obtain more homogenous dose distribution in target volume, while permitting to reduce the dose to critical organs.  相似文献   

18.
BackgroundThe present study was to investigate the usefulness of deep inspiration breath hold (DIBH) in bilateral breast patients using 6MV flattened beam (FB) and flattening filter free beam (FFFB).Materials and methodsTwenty bilateral breast cancer patients were simulated, using left breast patients treated with DIBH technique. CT scans were performed in the normal breathing (NB) and DIBH method. Three-dimensional conformal radiotherapy (3DCRT) and volumetric arc therapy (VMAT) plans were generated.ResultsIn our study the best organ at risk (OAR) sparing is achieved in the 3DCRT DIBH plan with adequate PTV coverage (V95 ≥ 47.5 Gy) as compared to 6MV FB and FFFB VMAT DIBH plans. The DIBH scan plan reduces the heart mean dose significantly at the rate of 49% in 3DCRT (p = 0.00) and 22% in VMAT (p = 0.010). Similarly, the DIBH scan plan produces lesser common lung mean dose of 18% in 3DCRT (p = 0.011) and 8% in VMAT (0.007) as compared to the NB scan. The conformity index is much better in VMAT FB (1.04 ± 0.04 vs. 1.04 ± 0.05), p =1.00 and VMAT FFFB (1.04 ± 0.05 vs. 1 ± 0.24, p = 0.345) plans as compared to 3DCRT (1.63 ± 0.2 vs. 1.47 ± 0.28, p = 0.002). The homogeneity index of all the plans is less than 0.15. The global dmax is more in VMAT FFFB DIBH plan (113.7%). The maximum MU noted in the NB scan plan (478 vs. 477MU, 1366 vs. 1299 MU and 1853 vs. 1788 MU for 3DCRT, VMAT FB and VMAT FFFB technique as compared to DIBH scan.ConclusionWe recommend that the use of DIBH techniques for bilateral breast cancer patients significantly reduces the radiation doses to OARs in both 3DCRT and VMAT plans.  相似文献   

19.
In this first attempt to model the distributions of a mesopelagic fish family at this scale in the eastern Australian region (10°S to 57°S), lanternfish species occurrence data spanning a period from 1928 to 2010 were modelled against environmental covariates. This involved: (1) data collation and taxonomic quality checking, (2) classification of trawls into “horizontal” (presence-absence) and “oblique” (presence-only) types, and classification of vertical migration patterns using existing literature and the species occurrence database, (3) binomial GAMs using presence-absence data for representative temperate, subtropical and tropical species to examine depth interactions with environmental covariates and refine the selection of environmental layers for presence-only MAXENT models, (4) Presence-only MAXENT modelling using data from all trawls and the reduced environmental layers, and (5) Multivariate analysis (area-wise and species-wise) of the resulting matrix of logistic score by geographic pixel. We test the hypothesis that major fronts in the region (Tasman Front, Subtropical Convergence, Subantarctic Front) represent zoogeographic boundaries. A four-region zoogeographic scheme is hypothesised: Coral Sea region, Subtropical Lower Water region, Subtropical Convergence/South Tasman region and Subantarctic region. The Tasman Front, Subtropical Convergence and Subantarctic Front represented zoogeographic boundaries. An additional boundary at ∼25°S (coined the ‘Capricorn’ boundary) was adopted to delineate the Coral Sea from Subtropical Lower Water regions. Lanternfish zoogeographic regions are congruent with some aspects of two prevailing physicochemical biogeographic schema in the region, but neither of these schema alone accurately predicts lanternfish distributions. As lanternfishes integrate vertical ocean processes, the hypothesised lanternfish zoogeography may represent a useful model for a generalised pelagic biogeography that should be tested for other oceanic groups.  相似文献   

20.
ObjectivesTo investigate the dosimetric effect of air gaps under bolus on skin dose for left-sided post-mastectomy radiotherapy with loco regional involvement.MethodsEight patients were planned retrospectively with volume modulated arc therapy (VMAT) and conventional static Field-in-Field (FinF) methods. Three different setups were applied for the 5-mm bolus over the chest wall having 0, 5 or 10 mm air gap under the bolus. The dose calculation was performed using Monte Carlo (MC) simulation. In addition, Analytic Anisotropic Algorithm (AAA) was used to demonstrate the differences observed in clinical setting.ResultsThe investigated air gaps under the bolus had minimal effect on surface dose for FinF plans (relative difference ≤ 2.6%), whereas for VMAT plans the surface dose decreased 13.6% when compared to the case with no air gap. In both FinF and VMAT, the largest differences between AAA and MC were seen at the surface where AAA underestimated the dose by 1.5 Gy (p < 0.05) on average; while the dose in the target volume excluding the surface was relatively similar being on average 0.3 Gy (p > 0.05) larger with AAA than with MC calculations.ConclusionsThe surface dose was significantly lower with VMAT technique than with FinF technique. Possible air gaps under the bolus reduced the surface dose significantly further for VMAT but not for FinF treatments, which may have clinical impact on recurrence rate. AAA was shown to underestimate the surface dose when compared to MC calculation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号