首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
A novel amperometric nonenzymatic glucose sensor based on Au-doped NiO nanobelts has been successfully fabricated and applied to nonenzymatic glucose detection. Its electrochemical behavior towards the oxidation of glucose was compared with NiO nanofibers and Au microparticles prepared with a similar procedure. The NiO-Au hybrid nanobelts modified electrode displays greatly enhanced electrocatalytic activity towards glucose oxidation, revealing a synergistic effect between the matrix NiO and the doped Au. The as-prepared NiO-Au nanobelts based glucose sensor displays significantly lower onset potential, lower detection limit, higher sensitivity, and wider linear range than that of pristine NiO nanofibers modified electrode. Moreover, Au nanoparticles distributed in NiO nanofibers enabled amperometric glucose detection with insignificant interference from ascorbic acid and uric acid. These results indicate that the NiO-Au hybrid nanobelt is a promising candidate in the development of highly sensitive and selective nonenzymatic glucose sensors.  相似文献   

2.
The formation of neodymium hexacyanoferrate (NdHCF) nanoparticles (NPs) on the surface of glucose oxidase/chitosan (GOx/CHIT) modified glass carbon electrode induced by enzymatic reaction was described and characterized. CHIT can be used not only as enzyme immobilizer, but also to provide active sites for NPs growth. Results showed that the optimized conditions of the GOx/CHIT film induced NdHCF NPs for the biosensing of glucose were 1.0mM Nd(3+) and 20.0mM Fe(CN)(6)(3-). The biocatalyzed generation of NdHCF NPs enabled the development of an electrochemical biosensor for glucose. The calculated apparent Michaelis-Menten constant was 7.5mM. The linear range for glucose detection was 0.01-10.0mM with the correlation coefficient of 0.9946, and the detection limit was 5muM (S/N=3). Furthermore, this system avoids the interferences of other species during the biosensing process and can be used for the determination of glucose in human plasma samples.  相似文献   

3.
A novel amperometric glucose sensor was constructed by immobilizing glucose oxidase (GOD) in a titania sol-gel film, which was prepared with a vapor deposition method. The sol-gel film was uniform, porous and showed a very low mass transport barrier and a regular dense distribution of GOD. Titania sol-gel matrix retained the native structure and activity of entrapped enzyme and prevented the cracking of conventional sol-gel glasses and the leaking of enzyme out of the film. With ferrocenium as a mediator the glucose sensor exhibited a fast response, a wide linear range from 0.07 to 15 mM. It showed a good accuracy and high sensitivity as 7.2 microA cm(-2) mM(-1). The general interferences coexisted in blood except ascorbic acid did not affect glucose determination, and coating Nafion film on the sol-gel film could eliminate the interference from ascorbic acid. The serum glucose determination results obtained with a flow injection analysis (FIA) system showed an acceptable accuracy, a good reproducibility and stability and indicated the sensor could be used in FIA determination of glucose. The vapor deposition method could fabricate glucose sensor in batches with a very small amount of enzyme.  相似文献   

4.
A new highly catalytic and intensely sensitive amperometric sensor based on PtM (where M=Pd, Ir) bimetallic nanoparticles (NPs) for the rapid and accurate estimation of hydrogen peroxide (H(2)O(2)) by electrooxidation in physiological conditions is reported. PtPd and PtIr NPs-decorated multiwalled carbon nanotube nanocatalysts (PtM/MWCNTs) were prepared by a modified Watanabe method, and were characterized by XRD, TEM, ICP, and XAS. The sensors were constructed by immobilizing PtM/MWCNTs nanocatalysts in a Nafion film on a glassy carbon electrode. Both PtPd/MWCNTs and PtIr/MWCNTs assemblies catalyzed the electrochemical oxidation of H(2)O(2). Cyclic voltammetry characterization measurements revealed that both the PtM (M=Pd, Ir)/MWCNTs/GCE possessed similar electrochemical surface areas (~0.55 cm(2)), and electron transfer rate constants (~1.23 × 10(-3)cms(-1)); however, the PtPd sensor showed a better performance in H(2)O(2) sensing than did the PtIr counterpart. Explanations were sought from XAS measurements to explain the reasons for differences in sensor activity. When applied to the electrochemical detection of H(2)O(2), the PtPd/MWCNTs/GC electrode exhibited a low detection limit of 1.2 μM with a wide linear range of 2.5-125 μM (R(2)=0.9996). A low working potential (0V (SCE)), fast amperometric response (<5s), and high sensitivity (414.8 μA mM(-1)cm(-2)) were achieved at the PtPd/MWCNTs/GC electrode. In addition, the PtPd/MWCNTs nanocatalyst sensor electrode also exhibited excellent reproducibility and stability. Along with these attractive features, the sensor electrode also displayed very high specificity to H(2)O(2) with complete elimination of interference from UA, AA, AAP and glucose.  相似文献   

5.
We report the design, construction, and testing of a contact lens with an integrated amperometric glucose sensor, proposing the possibility of in situ human health monitoring simply by wearing a contact lens. The glucose sensor was constructed by creating microstructures on a polymer substrate, which was subsequently shaped into a contact lens. Titania sol-gel film was applied to immobilize glucose oxidase, and Nafion? was used to decrease several potential interferences (ascorbic acid, lactate, and urea) present in the tear film. The sensor exhibits a fast response (20s), a high sensitivity (240 μA cm(-2) mM(-1)) and a good reproducibility after testing a number of sensors. It shows good linearity for the typical range of glucose concentrations in the tear film (0.1-0.6 mM), and acceptable accuracy in the presence of interfering agents. The sensor can attain a minimum detection of less than 0.01 mM glucose.  相似文献   

6.
Catecholamine detection using enzymatic amplification   总被引:2,自引:0,他引:2  
Different amplification sensors based on the substrate recycling principle were investigated with respect to their applicability to catecholamine detection. In the bioelectrocatalytic approach, glassy carbon electrodes were modified by laccase or a PQQ-dependent glucose dehydrogenase. Substrate recycling occurs and the detection limit is in the lower nanomolar concentration range (e.g. 10 nM dopamine and 1 nM noradrenaline for the laccase- and glucose dehydrogenase-modified electrodes, respectively). Combinations of glucose dehydrogenase with laccase or tyrosinase were investigated as bienzymatic probes. Among the systems we studied, the laccase/glucose dehydrogenase sensor is the most sensitive (detection limit: 0·5 nM adrenaline). The selectivities of the different sensor systems are discussed. Application of the laccase/glucose dehydrogenase electrode in different media (i.e. brain homogenate, heart effluate) was successfully shown. For samples with high concentrations of interfering substances (uric and ascorbic acid), the interferences can be effectively removed using enzymatic methods.  相似文献   

7.
A highly sensitive electrochemical glucose sensor has been developed by the co-immobilization of glucose oxidase (GOx) and horseradish peroxidase (HRP) onto a gold electrode modified with biocompatible cyclic bisureas–gold nanoparticle conjugate (CBU–AuNP). A self-assembled monolayer of mercaptopropionic acid (MPA) and CBU–AuNP was formed on the gold electrode through a layer-by-layer assembly. This modified electrode was used for immobilization of the enzymes GOx and HRP. Both the HRP and GOx retained their catalytic activity for an extended time, as indicated by the low value of Michaelis–Menten constant. Analytical performance of the sensor was examined in terms of sensitivity, selectivity, reproducibility, lower detection limit, and stability. The developed sensor surface exhibited a limit of detection of 100 nM with a linear range of 100 nM to 1 mM. A high sensitivity of 217.5 μA mM−1 cm−2 at a low potential of −0.3 V was obtained in this sensor design. Various kinetic parameters were calculated. The sensor was examined for its practical clinical application by estimating glucose in human blood sample.  相似文献   

8.
In the pursuit of more economical electrocatalysts for non-enzymatic glucose sensors, one-dimensional Cu nanowires (Cu NWs) with uniform size distribution and a large aspect ratio (>200) were synthesized by a facile, scalable, wet-chemistry approach. The morphology, crystallinity, and surface property of the as-prepared Cu NWs were examined by SEM, XRD, and XPS, respectively. The electrochemical property of Cu NWs for glucose electrooxidation was thoroughly investigated by cyclic voltammetry. In the amperometric detection of glucose, the Cu NWs modified glassy carbon electrode exhibited an extraordinary limit of detection as low as 35 nM and a wide dynamic range with excellent sensitivity of 420.3 μA cm(-2) mM(-1), which was more than 10,000 times higher than that of the control electrode without Cu NWs. The performance of the developed glucose sensor was also independent to oxygen concentration and free from chloride poisoning. Furthermore, the interference from uric acid, ascorbic acid, acetaminophen, fructose, and sucrose at the level of their physiological concentration were insignificant, indicating excellent selectivity. Finally, good accuracy and high precision for the quantification of glucose concentration in human serum samples implicate the applicability of Cu NWs in sensitive and selective non-enzymatic glucose detection.  相似文献   

9.
A novel detection system for the determination of glucose in the presence of clinically important interferents, based on the use of dual sensors and flow-injection analysis (FIA), is described. The normalisation methodology involves measurement of the interference signal at a reference sensor; this signal can then be subtracted from the glucose sensor signal (post-run) to give a corrected measurement of the glucose concentration. The detection system consists of a thin layer cell with dual glassy carbon working electrodes. One electrode was surface modified to act asglucose biosensor by immobilisation of glucose oxidase (GOx) (from Aspergillus niger) with 1% glutaraldehyde and bovine serum albumin. The second electrode (glucose oxidase omitted) was utilised to measure the interference signal responding only to electroactive species present in the injected sample. A computer controlled multichannel potentiostat was used for potential application and current monitoring duties. The sensor responses were saved in ASCII format to facilitate post-run analysis in Microsoft Excel. Cyclic voltammetry (CV) was utilised to investigate the manner in which the interference signal contributed to the total signal obtained at the biosensor in the presence of glucose. The kinetic parameters Imax and the apparent Michaelis-Menten constant, K′m, were calculated for the sensor operating under flow-injection conditions.  相似文献   

10.
A novel amperometric glucose sensor based on co-immobilization of ferrocenemethanol (MeOHFc) and glucose oxidase (GOD) in the layered double hydroxides (LDHs) was described. MeOHFc immobilized in LDHs played effectively the role of an electron shuttle and allowed the detection of glucose at 0.25 V (versus SCE), with dramatically reduced interference from easily oxidizable constituents. The sensor (LDHs/MeOHFc/GOD) exhibited a relatively fast response (response time was about 5s), low detection limit (3 microM), and high sensitivity (ca. 60 mA M(-1)cm(-2)) with a linear range of 6.7 x 10(-6) to 3.86 x 10(-4)M of glucose. Apparent Michaelis-Menten constant was calculated to be 2.25 mM.  相似文献   

11.
We have developed an amperometric glucose sensor whose electrodes are coated with a four-layered membrane: 3-aminopropyltriethoxysilane (gamma-APTES), Nafion, glucose oxidase (GOX), and perfluorocarbon polymer (PFCP). Tests demonstrate the sensor's ability to accurately and successively determine glucose concentrations ranging from 2.8 to 167 mM, over a 66 day period with no increase in response time, while remaining imperviousness to the effects of interference species (2.8 mM ascorbic acid, 0.3 mM uric acid, 0.3 mM p-acetaminophen). Furthermore, tests on diabetic urine samples showed an excellent correlation coefficient of 0.985 (y=1.04x+4.73, n=30) between sensor results and those of Glucose-Dehydrogenase clinical laboratory analyses.  相似文献   

12.
A nonenzymatic electrochemical sensor device was fabricated for glucose detection based on nickel nanoparticles (NiNPs)/straight multi-walled carbon nanotubes (SMWNTs) nanohybrids, which were synthesized through in situ precipitation procedure. SMWNTs can be easily dispersed in solution after mild sonication pretreatment, which facilitates the precursor of NiNPs binding to their surface and results in the homogeneous distribution of NiNPs on the surface of SMWNTs. The morphology and component of the nanohybrids were characterized by scanning electron microscopy (SEM) and X-ray powder diffraction (XRD), respectively. Cyclic voltammetry (CV) and amperometry were used to evaluate the catalytic activity of the NiNPs/SMWNTs nanohybrids modified electrode towards glucose. It was found that the nanohybrids modified electrode showed remarkably enhanced electrocatalytic activity towards the oxidation of glucose in alkaline solution compared to that of the bare glass carbon electrode (GCE), the NiNPs and the SMWNTs modified electrode, attributing to the synergistic effect of SMWNTs and Ni2+/Ni3+ redox couple. Under the optimal detection conditions, the as-prepared sensors exhibited linear behavior in the concentration range from 1 μM to 1 mM for the quantification of glucose with a limit of detection of 500 nM (3σ). Moreover, the NiNPs/SMWNTs modified electrode was also relatively insensitive to commonly interfering species such as ascorbic acid (AA), uric acid (UA), dopamine (DA), galactose (GA), and xylose (XY). The robust selectivities, sensitivities, and stabilities determined experimentally indicated the great potential of NiNPs/SMWNTs nanohybrids for construction of a variety of electrochemical sensors.  相似文献   

13.
Shi J  Ci P  Wang F  Peng H  Yang P  Wang L  Ge S  Wang Q  Chu PK 《Biosensors & bioelectronics》2011,26(5):2579-2584
A silicon microchannel plate (MCP) array electrode modified with over-oxidized polypyrrole (OPPy) has been fabricated to detect glucose. The morphology and structure of the electrode are characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The OPPy modified silicon MCP array electrode exhibits high electrocatalytic activity as well as excellent selectivity to the electrochemical oxidation of glucose. At a potential of +0.08 V, good sensitivity of 0.37 mA mM(-1) cm(-2) and detection limit of 2.06 μM are attained. The linear range is up to 24 mM with a linear correlation coefficient of 0.997. Furthermore, the electrode is highly resistant to interfering substances because the effects of common coexisting substances can be effectively eliminated by the OPPy film and the response in the current to interferences on the electrode surface is almost negligible. This novel electrode has high potential in nonenzymatic detection of glucose.  相似文献   

14.
The direct electrochemistry of glucose oxidase (GOD) adsorbed on a colloidal gold modified carbon paste electrode was investigated. The adsorbed GOD displayed a pair of redox peaks with a formal potential of -(449+/-1) mV in 0.1 M pH 5.0 phosphate buffer solution. The response showed a surface-controlled electrode process with an electron transfer rate constant of (38.9+/-5.3)/s determined in the scan rate range from 10 to 100 mV/s. GOD adsorbed on gold colloid nanoparticles maintained its bioactivity and stability. The immobilized GOD could electrocatalyze the reduction of dissolved oxygen and resulted in a great increase of the reduction peak current. Upon the addition of glucose, the reduction peak current decreased, which could be used for glucose detection with a high sensitivity (8.4 microA/mM), a linear range from 0.04 to 0.28 mM and a detection limit of 0.01 mM at a signal-to-noise ratio of 3sigma. The sensor could exclude the interference of commonly coexisted uric and ascorbic acid.  相似文献   

15.
Novel nickel and copper oxide nanoparticle modified polyaniline (PANI) nanofibers (NiO/CuO/PANI) were fabricated and used as a non-enzymatic sensor for detecting glucose. PANI nanofibers were prepared through electrodeposition, whereas nickel and copper oxide nanoparticles were deposited on PANI nanofibers by electrodeposition and electrochemical oxidation in situ. The morphology and structure of NiO/CuO/PANI nanocomposites were characterized by field emission scanning electron microscopy (FE–SEM), X-ray diffraction (XRD), Raman spectroscopy, and Fourier transform infrared (FT–IR). The as-prepared NiO/CuO/PANI electrode was employed for non-enzymatic glucose detection in alkaline electrolyte and showed better electrocatalytic activity compared with the PANI, CuO/PANI, and NiO/PANI electrodes. Consequently, an amperometric electrode of glucose was achieved under 0.6 V versus Ag/AgCl with a wide linear range from 20 to 2500 μM (R2 = 0.9978) and a low detection limit of 2.0 μM (signal/noise [S/N] = 3). This electrode can effectively analyze glucose concentration in human serum samples, avoiding interference, and is a promising non-enzymatic glucose sensor due to its low overpotential, high sensitivity, good selectivity and stability, fast response, and low cost.  相似文献   

16.
Escherichia coli cells, which contain apo-glucose dehydrogenase, were used in constructing a mediated amperometric glucose sensor. The E. coli modified glucose sensor, which was prepared by immobilizing E. coli cells behind a dialysis membrane on a carbon paste electrode containing 2,3-dimethoxy-5-methyl-1,4-benzoquinone (Q(0)), produced a current for the electrocatalytic oxidation of glucose with Q(0) as an electron transfer mediator only after the addition of a trace amount of pyrroloquinoline quinone (PQQ), the cofactor of the enzyme. This allows a novel method of glucose measurements free from the interference of the redox active substances, if contained, in a sample solution. The glucose sensor was insensitive to dioxygen; the currents measured under anaerobic and aerobic conditions, and even under dioxygen saturated conditions were almost the same in magnitude at a given concentration of glucose over the range of 0.2-10 mM. Response time of the glucose sensor was 2 min to attain 90% level of the steady-state current. The E. coli modified glucose sensor was reusable when treated with ethylenediaminetetraacetic acid (EDTA). When E. coli cells were lyophilized, they could be stored at room temperature in a dry box for more than six months without loss of the catalytic activity.  相似文献   

17.
A non-enzymatic glucose sensor of multi-walled carbon nanotube-ruthenium oxide/composite paste electrode (MWCNT-RuO(2)/CPE) was developed. The electrode was characterized by using XRD, SEM, TEM and EIS. Meanwhile, cyclic voltammetry and amperometry were used to check on the performances of the MWCNT-RuO(2)/CPE towards glucose. The proposed electrode has displayed a synergistic effect of RuO(2) and MWCNT on the electrocatalytic oxidation of glucose in 3M NaOH. This was possible via the formation of transitions of two redox pairs, viz. Ru(VI)/Ru(IV) and Ru(VII)/Ru(VI). A linear range of 0.5-50mM glucose and a limit of detection of 33μM glucose (S/N=3) were observed. There was no significant interference observable from the traditional interferences, viz. ascorbic acid and uric acid. Indeed, results so obtained have indicated that the developed MWCNT-RuO(2)/CPE would pave the way for a better future to glucose sensor development as its fabrication was without the use of any enzyme.  相似文献   

18.
Calcium carbonate nanoparticles (nano-CaCO3) may be a promising material for enzyme immobilization owing to their high biocompatibility, large specific surface area and their aggregation properties. This attractive material was exploited for the mild immobilization of glucose oxidase (GOD) in order to develop glucose amperometric biosensor. The GOD/nano-CaCO3-based sensor exhibited a marked improvement in thermal stability compared to other glucose biosensors based on inorganic host matrixes. Amperometric detection of glucose was evaluated by holding the modified electrode at 0.60 V (versus SCE) in order to oxidize the hydrogen peroxide generated by the enzymatic reaction. The biosensor exhibited a rapid response (6s), a low detection limit (0.1 microM), a wide linear range of 0.001-12 mM, a high sensitivity (58.1 mAcm-2M-1), as well as a good operational and storage stability. In addition, optimization of the biosensor construction, the effects of the applied potential as well as common interfering compounds on the amperometric response of the sensor were investigated and discussed herein.  相似文献   

19.
A rapid prototyping of an inexpensive, disposable graphene and copper nanocomposite sensor strip using polymeric flexible substrate for highly sensitive and selective nonenzymatic glucose detection has been developed and tested for direct oxidization of glucose. The CuNPs were electrochemically deposited on to the graphene sheets to improve electron transfer rates and to enhance electrocatalytic activity toward glucose. The graphene based electrode with CuNPs demonstrated a high degree of sensitivity (1101.3±56 μA/mM.cm2), excellent selectivity (without an interference with Ascorbic Acid, Uric Acid, Dopamine, and Acetaminophen), good stability with a linear response to glucose ranging from 0.1 mM to 0.6 mM concentration, and detection limits of 0.025 mM to 0.9 mM. Characterization of the electrodes was performed by scanning electron microscopy (FESEM and SEM). The electrochemical properties of the modified graphene electrodes were inspected by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and amperometry.  相似文献   

20.
Cobalt hexacyanoferrate nanoparticles (CoNP) can be easily prepared by mixing hexacyanoferrate and cobalt chloride solution at room temperature. The nanoparticles were solubilized in aqueous solution of a biopolymer chitosan (CHIT). With the introduction of carbon nanotubes (CNT), the CoNP-CNT-CHIT system formed shows synergy between CNT and CoNP with the significant improvement of redox activity of CoNP due to the excellent electron-transfer ability of CNT. The CoNP-CNT-CHIT film modified glassy carbon electrode allows low potential detection of hydrogen peroxide with high sensitivity and fast response time. In particular, with the introduction of CNT, it amplified the H2O2 sensitivity by approximately 70 times compared to film of CoNP-CHIT. With the immobilization of glucose oxidase onto the electrode surface using glutaric dialdehyde, a biosensor that responds sensitively to glucose has been constructed. In pH 6.98 phosphate buffer, interference free determination of glucose has been realized at -0.2V versus saturated calomel electrode (SCE) with a linear range from 0.01 to 10 mM and response time<10s. The detection limit was 5 microM glucose (S/N=3).  相似文献   