首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Assaying for transgenic pollen, a major vector of transgene flow, provides valuable information and essential data for the study of gene flow and assessing the effectiveness of transgene containment. Most studies have employed microscopic screening methods or progeny analyses to estimate the frequency of transgenic pollen. However, these methods are time-consuming and laborious when large numbers of pollen grains must be analyzed to look for rare transgenic pollen grains. Thus, there is an urgent need for the development of a simple, rapid, and high throughput analysis method for transgenic pollen analysis. In this study, our objective was to determine the accuracy of using flow cytometry technology for transgenic pollen quantification in practical application where transgenic pollen is not frequent. A suspension of non-transgenic tobacco pollen was spiked with a known amount of verified transgenic tobacco pollen synthesizing low or high amounts of green fluorescent protein (GFP). The flow cytometric method detected approximately 75% and 100% of pollen grains synthesizing low and high amounts of GFP, respectively. The method is rapid, as it is able to count 5000 pollen grains per minute-long run. Our data indicate that this flow cytometric method is useful to study gene flow and assessment of transgene containment.  相似文献   

2.
3.
We describe a rapid assay for measuring the cellular activity of small guanine triphosphatases (GTPases) in response to a specific stimulus. Effector-functionalized beads are used to quantify in parallel multiple GTP-bound GTPases in the same cell lysate by flow cytometry. In a biologically relevant example, five different Ras family GTPases are shown for the first time to be involved in a concerted signaling cascade downstream of receptor ligation by Sin Nombre hantavirus.  相似文献   

4.
A simple, rapid and reliable method has been developed for assessing the number and viability of cells, as well as cell size, in suspension culture by the use of flow cytometry. Propidium iodide exclusion is used for viability determination and fluorescent beads serve as an internal standard for cell enumeration. The main advantages of this method are its ability to handle a large number of samples with a high degree of precision and its specificity in detecting viable cells quantitatively in a heterogeneous culture of living and dead cells and debris. The method shows only a fraction of the variation found in the haemacytometer/trypan blue counting method due to its very low operator dependence. CHO - Chinese hamster ovary; FCS - Foetal calf serum; FS - Forward scatter light; MTT - 3-(4,5-dimethylthiazolyl-2)-2,5-diphenyltetrazolium bromide; NCS - newborn calf serum; PBS - Phosphate buffered saline; PI - Propidium iodide; SS - Side scatter light. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

5.
A new staining protocol is described for the immunocytochemical detection of BrdUrd labeled nuclei. Pepsin treatment of ethanol fixed cells or tissue, followed by DNA denaturation at low pH, resulted in increased sensitivity of BrdUrd staining comparable to the thermal denaturation protocol, and decreased background binding. This technique is applicable to cell suspensions, including cultured cells and bone marrow cells. Furthermore, pepsin digestion of ethanol fixed tissue fragments resulted in a high recovery of nuclei in which incorporated BrdUrd could be detected. This possibility, together with the high sensitivity, make this method especially suitable for cell kinetic studies of human solid tumors in vivo.  相似文献   

6.
Application of flow cytometry (FCM) to microbial analysis of milk is hampered by the presence of milk proteins and lipid particles. Here we report on the development of a rapid (/= 0.98) between the FCM assay and the more conventional methods of plating and direct microscopic counting was achieved. Raw milk data showed a significant correlation (P < 0.01) and a good agreement (r = 0.91) between FCM and standard plate count methods. The detection limit of the FCM assay was 相似文献   

7.
8.
Legionella species are the causative agents of human legionellosis, and bathing facilities have been identified as the sources of infection in several outbreaks in Japan. Researchers in Japan have recently reported evidence of significant associations between bacterial counts and the occurrence of Legionella in bathing facilities and in a hot tub model. A convenient and quantitative bacterial enumeration method is therefore required as an indicator of Legionella contamination or disinfection to replace existing methods such as time-consuming Legionella culture and expensive Legionella-DNA amplification. In this study, we developed a rapid detection method (RDM) to monitor the risk of Legionella using an automated microbial analyzing device based on flow cytometry techniques to measure the total number of bacteria in water samples within two minutes, by detecting typical patterns of scattered light and fluorescence. We first compared the results of our RDM with plate counting results for five filtered hot spring water samples spiked with three species of bacteria, including Legionella. Inactivation of these samples by chlorine was also assessed by the RDM, a live/dead bacterial fluorescence assay and plate counting. Using the RDM, the lower limit of quantitative bacterial counts in the spiked samples was determined as 3.0 × 103 (3.48 log) counts mL− 1. We then used a laboratory model of a hot tub and found that the RDM could monitor the growth curve of naturally occurring heterotrophic bacteria with 1 and 2 days' delayed growth of amoeba and Legionella, respectively, and could also determine the killing curve of these bacteria by chlorination. Finally, samples with ≥ 3.48 or < 3.48 log total bacterial counts mL− 1 were tested using the RDM from 149 different hot tubs, and were found to be significantly associated with the positive or negative detection of Legionella with 95% sensitivity and 84% specificity. These findings indicated that the RDM can be used for Legionella control at bathing facilities, especially those where the effectiveness of chlorine is reduced by the presence of Fe2+, Mn2+, NH4+, skin debris, and/or biofilms in the water.  相似文献   

9.
10.
To transform the linear fluorescence intensity scale obtained with fluorescent microspheres to an antibody bound per cell (ABC) scale, a biological cell reference material is needed. Optimally, this material should have a reproducible and tight ABC value for the expression of a known clinical reference biomarker. In this study, we characterized commercially available cryopreserved peripheral blood mononuclear cells (PBMCs) and two lyophilized PBMC preparations, Cyto-Trol and PBMC-National Institute for Biological Standard and Control (NIBSC) relative to freshly prepared PBMC and whole blood samples. It was found that the ABC values for CD4 expression on cryopreserved PBMC were consistent with those of freshly obtained PBMC and whole blood samples. By comparison, the ABC value for CD4 expression on Cyto-Trol is lower and the value on PBMC-NIBSC is much lower than those of freshly prepared cell samples using both conventional flow cytometry and CyTOF? mass cytometry. By performing simultaneous surface and intracellular staining measurements on these two cell samples, we found that both cell membranes are mostly intact. Moreover, CD4(+) cell diameters from both lyophilized cell preparations are smaller than those of PBMC and whole blood. This could result in steric interference in antibody binding to the lyophilized cells. Further investigation of the fixation effect on the detected CD4 expression suggests that the very low ABC value obtained for CD4(+) cells from lyophilized PBMC-NIBSC is largely due to paraformaldehyde fixation; this significantly decreases available antibody binding sites. This study provides confirmation that the results obtained from the newly developed mass cytometry are directly comparable to the results from conventional flow cytometry when both methods are standardized using the same ABC approach.  相似文献   

11.
A reliable and rapid test to detect cytotoxic chemicals which affect cell membranes is described. Fluorescein diacetate freely penetrates intact cells where it is hydrolyzed to its fluorochrome, fluorescein, which is retained in the cell due to its polarity. On the other hand, ethidium bromide is known to be excluded from the intact cell, staining only nucleic acids of membrane-damaged cells. The combination of both fluorochromes results in counter-staining: intact cells fluoresce green (cytoplasm) and membrane-damaged cells fluoresce red (nucleus and RNA). Rat thymocytes freshly isolated without enzyme treatment were incubated simultaneously with test substance and dye solution fluorescein diacetate and ethidium bromide. A two-parameter analysis was performed on a flow cytometer with an on-line computer. Concentration-dependent effects of various detergents and solvents were quantified by measuring the amount of dye retention, i.e., the decrease or increase in fluorescein—fluorescence (peak shift), and the decrease in dye exclusion (increase in ethidium bromide-staining) relative to the untreated control. The assay can be used for rapid monitoring of chemical insults to cell membranes which precede the decrease of the viability measured by pure dye exclusion techniques.Abbreviations DMA dimethyl sulfate - DMSO dimethyl sulfoxide - EB ethidium bromide - F fluorescein - FDA fluorescein diacetate - FS25 concentration of test substance resulting in a F-peak left-shift of 25% from control - PBS phosphate buffered saline - SCT forward light scatter - SDS sodium dodecyl sulfate  相似文献   

12.
BACKGROUND: The tools for high throughput flow cytometry have been limited in part because of the requirement that the samples must flow under pressure. We describe a simple system for sampling repetitively from an open vessel. METHODS: Under computer control, the sample is loaded into a sample loop in a reciprocating eight-way valve by the action of a syringe. When the valve position is switched, the plug of sample in the sample loop is transported to the flow cytometer by a pressure-driven fluid line. By coupling the plug-forming capability to a second multi-port valve, samples can be delivered sequentially from separate vessels. RESULTS: The valve is able to deliver samples at rates ranging up to about 9 samples per minute. Each plug of sample has uniform delivery characteristics with a reproducible coefficient of variation (CV). Even at the highest sampling rate, carryover between samples is limited. CONCLUSIONS: Plug-flow flow cytometry has the potential to automate the delivery of small samples from unpressurized sources at rates compatible with many screening and assay applications.  相似文献   

13.
【目的】建立一种基于单克隆抗体的多元弧菌流式细胞仪检测技术。【方法】以副溶血弧菌表面蛋白r-OmpW的单克隆抗体(mAb)为基础,以细胞染色率为指标优化流式细胞仪检测副溶血弧菌时所需mAb的反应浓度和反应时间。通过菌落数对比评价在优化条件下流式细胞术方法的准确度、检出限和精密度。根据所建立的流式细胞术平台分析鉴定单抗对其它5种多元弧菌的特异性。【结果】流式细胞仪检测副溶血弧菌时所需r-OmpW单克隆抗体的优化反应浓度为20 mg/L,反应时间为60 min。当菌浓在104 107cells/mL范围时,检测值可信度较高,可特异性识别5种病原弧菌。对含不同菌体浓度的样品进行重复检测,变异系数均在7%以内。【结论】所建立的这种基于单克隆抗体的多元弧菌流式细胞仪检测技术可快速准确地检测多种病原弧菌。  相似文献   

14.
Measurement of poly(ADP-ribose) levels was performed by a new method using a monoclonal antibody against poly(ADP-ribose) and flow cytometry from small amount of cultured cells without the need for isolation of poly(ADP-ribose) polymer. The increase of poly(ADP-ribose)-associated fluorescence intensity was observed in individual human leukemic HL-60 cells when treated with the carcinogen, N-methyl-N'-nitro-N-nitrosoguanidine (MNNG), and was blocked by the treatment with 3-aminobenzamide before MNNG treatment. It is easy and rapid to detect the time-dependent change of poly(ADP-ribose) levels in HL-60 cells after MNNG treatment. We easily found that the increase of the poly(ADP-ribose) level in nicotinic acid-treated lymphocytes after MNNG treatment was observed, but not in nicotinamide-treated lymphocytes. We investigated the change of poly(ADP-ribose) levels especially in the early phase of apoptosis. Our method is simple and rapid. It is suggested that the investigation of poly(ADP-ribosyl)ation in various fields is possible by using this new method.  相似文献   

15.
Apoptosis and necrosis play an important role in various aspects of preclinical pharmaceutical drug discovery and validation. The ability to quickly determine the cytotoxic effect of chemical compounds on cancer cells allows researchers to efficiently identify potential drug candidates for further development in the pharmaceutical discovery pipeline. Recently, a new imaging cytometry system has been developed by Nexcelom Bioscience LLC (Lawrence, MA, USA) for fluorescence-based cell population analysis. Currently, fluorescence-based cell death assays have not been demonstrated by the Cellometer system, which can potentially provide a quick, simple, and inexpensive alternative method for smaller biomedical research laboratories. In this study, we demonstrate for the first time the use of Cellometer imaging cytometry for necrosis/apoptosis detection by studying the dose–response effect of heat and drug-induced cell death in Jurkat cells labeled with annexin V-FITC (apoptotic) and propidium iodide (necrotic). The experimental results were evaluated to validate the imaging cytometric capabilities of the Cellometer system as compared to the conventional flow cytometry. Similar cell population results were obtained from the two methods. The ability of Cellometer to rapidly and cost-effectively perform fluorescent cell-based assays has the potential of improving research efficiency, especially where a flow or laser scanning cytometer is not available or in situations where a rapid analysis of data is desired.  相似文献   

16.
New method to characterize microbial diversity using flow cytometry   总被引:2,自引:0,他引:2  
The majority of microorganisms have yet to be cultivated and represent a vast uncharacterized and untapped resource. Here, we report the utilization of a combination of flow cytometry, cultivation, and molecular genetics to develop new methodologies to access and characterize biodiversity in microbial samples. We demonstrate that fluorescent dyes and combinations of dyes can selectively stain portions of bacterial populations that can be isolated as sub-populations using fluorescence-activated cell sorting (FACS). Microbial sub-populations obtained by FACS differ substantially from the original microbial population, as demonstrated by denaturing gradient gel electrophoresis and determination of 16S rRNA gene sequences. These sub-populations can subsequently be used to inoculate microbial growth media, allowing the isolation of different microbial species from those that can be readily cultivated from the original sample using the same microbial growth media. When this technique was applied to the analysis of activated-sludge and Yellowstone Lake hydrothermal vent samples, comparative analysis of 16S rDNA sequences revealed that FACS allowed the detection of numerous bacterial species, including previously unknown species, not readily detectable in the original sample due to low relative abundance. This approach may result in a convenient methodology to more thoroughly characterize microbial biodiversity.  相似文献   

17.
18.
A new multiplexed, bead-based method which utilizes nucleic acid hybridizations on the surface of microscopic polystyrene spheres to identify specific sequences in heterogeneous mixtures of DNA sequences is described. The method consists of three elements: beads (5.6-microm diameter) with oligomer capture probes attached to the surface, three fluorophores for multiplexed detection, and flow cytometry instrumentation. Two fluorophores are impregnated within each bead in varying amounts to create different bead types, each associated with a unique probe. The third fluorophore is a reporter. Following capture of fluorescent cDNA sequences from environmental samples, the beads are analyzed by flow cytometric techniques which yield a signal intensity for each capture probe proportional to the amount of target sequences in the analyte. In this study, a direct hybrid capture assay was developed and evaluated with regard to sequence discrimination and quantitation of abundances. The target sequences (628 to 728 bp in length) were obtained from the 16S/23S intergenic spacer region of microorganisms collected from polluted groundwater at the nuclear waste site in Hanford, Wash. A fluorescence standard consisting of beads with a known number of fluorescent DNA molecules on the surface was developed, and the resolution, sensitivity, and lower detection limit for measuring abundances were determined. The results were compared with those of a DNA microarray using the same sequences. The bead method exhibited far superior sequence discrimination and possesses features which facilitate accurate quantitation.  相似文献   

19.
BACKGROUND: Recent advances in flow cytometry have resulted in the development of reliable techniques for performing polychromatic (5-17 color) flow cytometry analysis. However, the data reduction and analysis involved in the resolution of hundreds of possible cellular subphenotypes identified, using a single polychromatic flow cytometry staining panel, presents a major obstacle to the successful application of this technology. METHODS: To generate two distinct collections of T cell populations with differentially expressed surface markers, cryopreserved lymph node cells from 5 melanoma patients vaccinated with the modified gp100(209-2M) melanoma peptide were stimulated with cognate peptide and cultured in either IL-21 + low-dose IL-2 or IL-15 + low-dose IL-2. In vitro stimulated (IVS) cells were interrogated using 8-color flow cytometry. Data were analyzed using Winlist Hyperlog and FCOM software, and 32 T cell subsets were resolved for each culture condition. Hierarchical clustering analysis was applied to the relative percentages of each subphenotype for both IVS conditions to determine if unique cell surface marker expression signatures were produced for each IVS culture. RESULTS: Sequential data analysis using Hyperlog and FCOM demonstrated that lymphocytes cultured in IL-21 + IL-2 had a distinctively different set of subphenotype signatures compared to cells grown in IL-15 + IL-2 for all 5 patients. Importantly, subsequent cluster analysis of all 32 subphenotype frequencies in each IVS test condition for all 5 patients reproducibly demonstrated that cellular subphenotypes produced after IL-21 + IL-2 IVS partitioned separately from subphenotypes produced by IL-15 + IL-2 IVS. CONCLUSIONS: The integrated sequential use of Hyperlog and FCOM software with cluster analysis algorithms for the reduction and analysis of polychromatic flow cytometry data produces an effective, rapid technique for the assessment of complex patterns of subphenotype expression between and within multiple test samples. This approach to data analysis may enhance the use of polychromatic flow cytometry for both research and clinical applications.  相似文献   

20.
Objective

Chromovert® Technology is presented as a new cell engineering technology to detect and purify living cells based on gene expression.

Methods

The technology utilizes fluorogenic oligonucleotide signaling probes and flow cytometry to detect and isolate individual living cells expressing one or more transfected or endogenously-expressed genes.

Results

Results for production of cell lines expressing a diversity of ion channel and membrane proteins are presented, including heteromultimeric epithelial sodium channel (αβγ-ENaC), sodium voltage-gated ion channel 1.7 (NaV1.7-αβ1β2), four unique γ-aminobutyric acid A (GABAA) receptor ion channel subunit combinations α1β3γ2s, α2β3γ2s, α3β3γ2s and α5β3γ2s, cystic fibrosis conductance regulator (CFTR), CFTR-Δ508 and two G-protein coupled receptors (GPCRs) without reliance on leader sequences and/or chaperones. In addition, three novel plasmid-encoded sequences used to introduce 3′ untranslated RNA sequence tags in mRNA expression products and differentially-detectable fluorogenic probes directed to each are described. The tags and corresponding fluorogenic signaling probes streamline the process by enabling the multiplexed detection and isolation of cells expressing one or more genes without the need for gene-specific probes.

Conclusions

Chromovert technology is provided as a research tool for use to enrich and isolate cells engineered to express one or more desired genes.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号