首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Flavonoids detected from a model legume plant, Lotus japonicus accessions Miyakojima MG-20 and Gifu B-129, were profiled using liquid chromatography Fourier transform ion cyclotron resonance mass spectrometry (LC-FTICR/MS). Five flavonols and two anthocyanidins were detected as aglycones. LC-FTICR/MS facilitated simultaneous detection of 61 flavonoids including compounds that have not been reported previously. Chemical information of the peaks such as retention time, lambdamax, m/z value of the quasi-molecular ion, m/z value of MS/MS fragment ions, and relative intensity of MS/MS fragments was obtained, along with the molecular formulas and conjugate structures. Fourteen were completely identified by comparison with authentic compounds. The high accuracy of m/z values, being 0.081 ppm between observed and theoretical values, allowed prediction of molecular formulas of unknown compounds with the help of isotope peak information for determination of chemical composition. Based on a predicted elemental composition, the presence of a novel nitrogen-containing flavonoid was proposed. A comparison of flavonoid profiles in flowers, stems, and leaves demonstrated that the flowers yielded the most complex profile, containing 30 flower-specific flavonoids including gossypetin glycosides and isorhamnetin glycosides. A comparison of flavonoid profiles between MG-20 and B-129 grown under the same conditions revealed that the accumulation of anthocyanins was higher in B-129 than MG-20, particularly in the stem. Developmental changes in the flavonoid profiles demonstrated that kaempferol glycosides increased promptly after germination. In contrast, quercetin glycosides, predominant flavonoids in the seeds, were not detectable in growing leaves.  相似文献   

2.
We report the results of our work to facilitate protein identification using tandem mass spectra and protein sequence databases. We describe a parallel version of SEQUEST (SEQUEST-PVM) that is tolerant toward arithmetic exceptions. The changes we report effectively separate search processes on slave nodes from each other. Therefore, if one of the slave nodes drops out of the cluster due to an error, the rest of the cluster will carry the search process to the end. SEQUEST has been widely used for protein identifications. The modifications made to the code improve its stability and effectiveness in a high-throughput production environment. We evaluate the overhead associated with the parallelization of SEQUEST. A prior version of software to preprocess LC/MS/MS data attempted to differentiate the charge states of ions. Singly charged ions can be accurately identified, but the software was unable to reliably differentiate tandem mass spectra of +2 and +3 charge states. We have designed and implemented a computational approach to narrow charge states of precursor ions from nominal resolution ion-trap tandem mass spectra. The preprocessing code, 2to3, determines the charge state of the precursor ion using its mass-to-charge ratio (m/z) and fragment ions contained in the tandem mass spectrum. For each possible charge state the program calculates the expected fragment ions that account for precursor ion m/z values. If any one of the numbers is less than an empirically determined threshold value then the spectrum corresponding to that charge state is removed. If both numbers are higher than the threshold value then +2 and +3 copies of the spectrum are kept. We present the comparison of results from protein identification experiments with and without using 2 to 3. It is shown that by determining the charge state and eliminating poor quality spectra 2to3 decreases the number of spectral files to be searched without affecting the search results. The decrease reduces computer requirements and researcher efforts for analysis of the results.  相似文献   

3.
T Kasama  S Handa 《Biochemistry》1991,30(22):5621-5624
Negative ion fast atom bombardment, low-energy collision-activated dissociation, and tandem mass spectrometry techniques were applied for the structural elucidation of gangliosides. The mass spectra were simplified by selecting a single molecular ion or fragment ion in the analysis of mixtures, and interference by background signals from the liquid matrix could be avoided. Introduction of collision-activated dissociation produced abundant fragment ions convenient for structural analysis. In the daughter scan mode, ions were produced by cleavage of the glycosidic bonds, and not by cleavage at the sugar ring. These ions all contain ceramide moieties, except the sialic acid fragment ion. In the parent scan mode, product ions resulting from cleavage at the sugar ring were detected beside the ions resulting from cleavage at the glycosidic bonds, and ions of oligosaccharide fragments were also detected. In parent scan mode spectra of gangliosides based on the sialic acid ion, all ions contained a sialic acid residue, and the observed ions were similar to those obtained in the high-energy collision-activated dissociation daughter scan mode. These results indicate the usefulness of low-energy collision-activated dissociation tandem mass spectrometry in the daughter and parent scan modes for the analysis of ganglioside structure, in combination with fast atom bombardment mass spectrometry and high-energy collision-activated dissociation mass spectrometry.  相似文献   

4.
GC/EI-MS-based metabolite profiling of derivatized polar fractions of crude plant extracts typically reveals several hundred components. Thereof, only up to one half can be identified using mass spectral and retention index libraries, the rest remains unknown. In the present work, the utility of GC/APCI(+)-QTOFMS for the annotation of unknown components was explored. Hence, EI and APCI(+) mass spectra of ~100 known components were extracted from GC/EI-QMS and GC/APCI(+)-QTOFMS profiles obtained from a methoximated and trimethylsilylated root extract of Arabidopsis thaliana. Based on this reference set, adduct and fragment ion formation under APCI(+) conditions was examined and the calculation of elemental compositions evaluated. During these studies, most of the components formed dominating protonated molecular ions. Despite the high mass accuracy (|Δm| ≤ 3 mDa) and isotopic pattern accuracy (mSigma ≤ 30) the determination of a component’s unique native elemental composition requires additional information, namely the number of trimethylsilyl and methoxime moieties as well as the analysis of corresponding collision-induced dissociation (CID) mass spectra. After all, the reference set was used to develop a strategy for the pairwise assignment of EI and APCI(+) mass spectra. Proceeding from these findings, the annotation of unidentified components detected by GC/EI-QMS using GC/APCI(+)-QTOFMS and corresponding deuterated derivatization reagents was attempted. For a total of 25 unknown components, pairs of EI and APCI(+) mass spectra were compiled and elemental compositions determined. Integrative interpretation of EI and CID mass spectra resulted in 14 structural hypotheses, of which seven were confirmed using authenticated standards.  相似文献   

5.
Searching spectral libraries in MS/MS is an important new approach to improving the quality of peptide and protein identification. The idea relies on the observation that ion intensities in an MS/MS spectrum of a given peptide are generally reproducible across experiments, and thus, matching between spectra from an experiment and the spectra of previously identified peptides stored in a spectral library can lead to better peptide identification compared to the traditional database search. However, the use of libraries is greatly limited by their coverage of peptide sequences: even for well‐studied organisms a large fraction of peptides have not been previously identified. To address this issue, we propose to expand spectral libraries by predicting the MS/MS spectra of peptides based on the spectra of peptides with similar sequences. We first demonstrate that the intensity patterns of dominant fragment ions between similar peptides tend to be similar. In accordance with this observation, we develop a neighbor‐based approach that first selects peptides that are likely to have spectra similar to the target peptide and then combines their spectra using a weighted K‐nearest neighbor method to accurately predict fragment ion intensities corresponding to the target peptide. This approach has the potential to predict spectra for every peptide in the proteome. When rigorous quality criteria are applied, we estimate that the method increases the coverage of spectral libraries available from the National Institute of Standards and Technology by 20–60%, although the values vary with peptide length and charge state. We find that the overall best search performance is achieved when spectral libraries are supplemented by the high quality predicted spectra.  相似文献   

6.
We report results of a mass-spectrometric-based strategy for determining the detailed structural features of N-linked oligosaccharides from glycoproteins. The method was used to characterize a series of intact, high mannose oligosaccharides isolated from human immunoglobulin M (IgM). The IgM was purified from a patient with Waldenstrom's macroglobulinemia. The strategy included releasing the oligosaccharides by digestion of the purified glycoprotein with endoglycosidase H, separating the released oligosaccharides by high resolution gel filtration, and derivatizing the resulting reducing termini with the uv-absorbing moiety, ethyl p-aminobenzoate. This particular derivative facilitates HPLC detection and provides centers for protonation and deprotonation enhancing liquid secondary ion mass spectra. Positive and negative ion spectra contained molecular species of similar abundance. However, fragment ion peaks yielding sequence information were significantly more prominent in the negative ion mass spectra. Furthermore, it was obvious that the fragmentation patterns differed substantially for linear and branched oligomers. For linear oligosaccharides, a smooth envelope of fragment ions was observed; from low to high mass there was an ordered decrease in ion abundance from both the reducing and nonreducing termini. This pattern of fragment ions was not observed for branched oligosaccharides since in these cases fragments at certain masses could not arise by single bond cleavages. Therefore, these fragments were either significantly reduced in abundance or absent as compared with identical fragments formed from linear molecules. Importantly, 200 pmol of an oligosaccharide could be derivatized, separated, and detected by mass spectrometry, allowing identification of previously unreported minor components of the IgM oligosaccharides. Therefore, this experimental strategy is particularly useful for the purification and detailed structural characterization of low abundance oligosaccharides isolated from heterogeneous biological samples.  相似文献   

7.
Because of the intrinsic physical properties of single- or double-charged ions, MALDI-based CID on these peptide precursor ions tends to be incomplete, resulting in a large number of MS/MS spectra unassigned or ambiguously identified. Consequently, the TOF/TOF high throughput capability may not be fully explored and utilized. Here, we describe a novel method for de novo sequence assignment of those MALDI TOF/TOF MS/MS spectra with incomplete or weak fragment ion series. In this approach, the deuterium-labeled lysine and leucine precursors were used in parallel to mass-tag the proteome of a metastatic human hepatocellular carcinoma (HCC) cell line during in vivo cell culturing. These stable isotope precursor markers not only position at terminal but at internal MS/MS fragment ions with the characteristic isotope pattern induced by multiple mass tagging in parallel. This enhanced signal specificity evidently resolved ambiguities in those sparse poor-quality TOF/TOF spectra by providing critical sequential links among MS/MS fragment ions. Our data-dependent approach was able to reduce many false-positives in current genome sequence-based peptide sequencing. With developing new algorithms accordingly, our approach is amenable for automation that will lead to more comprehensive and reliable identification for proteomes.  相似文献   

8.
Protonated molecular peptide ions and their product ions generated by tandem mass spectrometry appear as isotopologue clusters due to the natural isotopic variations of carbon, hydrogen, nitrogen, oxygen, and sulfur. Quantitation of the isotopic composition of peptides can be employed in experiments involving isotope effects, isotope exchange, and isotopic labeling by chemical reactions and in studies of metabolism by stable isotope incorporation. Both ion trap and quadrupole-time of flight mass spectrometry are shown to be capable of determining the isotopic composition of peptide product ions obtained by tandem mass spectrometry with both precision and accuracy. Tandem mass spectra of clusters of isotopologue ions obtained in profile mode are fit by nonlinear least squares to a series of Gaussian peaks which quantify the Mn/M0 values which define the isotopologue distribution (ID). To determine the isotopic composition of product ions from their ID, a new algorithm that predicts the Mn/M0 ratios and obviates the need to determine the intensity of all of the ions of an ID is developed. Consequently a precise and accurate determination of the isotopic composition of a product ion may be obtained from only the initial values of the ID, however, the entire isotopologue cluster must be isolated prior to fragmentation. Following optimization of the molecular ion isolation width, fragmentation energy, and detector sensitivity, the presence of isotopic excess (2H, 13C, 15N, 18O) is readily determined within 1%. The ability to determine the isotopic composition of sequential product ions permits the isotopic composition of individual amino acid residues in the precursor ion to be determined.  相似文献   

9.
The location of the most abundant peak of the molecular-ion pattern often differs from the molecular mass published in scientific databases. The location is also distinct from the value expected from average atomic masses. The cause of this phenomenon is a large number of atoms of carbon, sulfur, chlorine, bromine, silicon and boron. This due to the natural isotope abundances of some elements forming organic compounds. A parameter called location of the most abundant peak of an isotopometric cluster (LAPIC) denotes the location of the most abundant (the main) peak of an isotopomeric cluster, which is determined, e.g., by mass spectrometry and can be important for medium- and high-molecular mass compounds. The equations for LAPIC calculation are presented for elements usually observed in organic compounds. The LAPIC with elemental formula helps effectively, e.g., in mass spectra interpretation since the prediction of LAPIC allows the correct connection of the main peak of the investigated ion with the expected ion formula and the mass of the ion considered. This solution can be a substitute for the much more complex method of isotopometric analysis applied in mass spectra interpretation. [Figure: see text]. Differences of the most abundant peak location (Delta LAPIC(C)=f(n)) for carbon aggregates C(n).  相似文献   

10.
We describe a method to identify metabolites of proteins that eliminates endogenous background by using stable isotope labeled matrices. This technique allows selective screening of the intact therapeutic molecule and all metabolites using a modified precursor ion scan that monitors low molecular weight fragment ions produced during MS/MS. This distinct set of low mass ions differs between isotopically labeled and natural isotope containing species allowing excellent discrimination between endogenous compounds and target analytes. All compounds containing amino acids that consist of naturally abundant isotopes can be selected using this scanning technique for further analysis, including metabolites of the parent molecule. The sensitivity and selectivity of this technique is discussed with specific examples of insulin metabolites identified within a complex matrix using a range of different validated low mass target ions.  相似文献   

11.
Applicability of negative ion fast atom bombardment (FAB)-tandem mass spectrometry (MS/MS) was examined in trace mixture analyses and structural assignments of some isoprenoid diphosphates. Negative ion FAB-MS spectra using a glycerol matrix of these isoprenoid diphosphates showed predominantly molecular ions (M-H)- together with fragment ions at m/z 177 (H3P2O7)-, 176 (H2P2O7)-, 159 (HP2O6)-, and 79 (PO3)- which were characteristic of the diphosphate ester moiety. The molecular ions did not overlap with peaks arising from any impurities even when crude sample such as butanol extracts from enzymatic reaction mixtures were directly analyzed without any purification. Moreover, collisionally activated dissociation spectra of the molecular ion showed many structurally significant fragment ions which enabled us to elucidate the structures of such irregular alkyl chain moieties as those having a homoisoprenoid skeleton or substituted structures. These studies indicate that negative ion FAB-MS/MS is a simple and useful technique for trace mixture analysis and structure elucidation of isoprenoid diphosphates.  相似文献   

12.

Introduction

A novel approach of ion mobility tandem mass spectrometry (IMS-MS/MS) is applied to analysis of human glycourinome to obtain carbohydrate pattern data of congenital disorders of glycosylation patient. Overlapping of the complex carbohydrate mass range landscape has been highly reduced upon IMS-MS procedure, allowing more efficient identification by mapping and sequencing of glycan precursor ions, following their separation by mobility, according to difference in drift time through the traveling wave IMS cell. Intact and truncated N- and O-glycan structures modified by sialylation and fucosylation were identified according to their drift time separated molecular ions and submitted to fragmentation in a narrow mass window.

IMS CID MS/MS Analysis

The fragmentation spectra generated from the IMS separated precursor ions contain series of fragment ions maintaining the same mobility as their parent ions, and the assignment accuracy can be significantly enhanced.

Conclusion

According to the specific fragment ion patterns, carbohydrate epitopes described to be involved in pathological processes were assigned. A high potential of this glycomics-based strategy for clinical applications can be presented.  相似文献   

13.
Under negative ionization conditions, nominal mass calibration of the fast bombardment high field mass spectrometer and data system was accomplished using cesium iodide/glycerol as a reference. Mass calibration at --8 kV accelerating potential extends from m/z 387 to m/z 2170 using xenon fast atoms. Negative xenon FAB mass spectra for human angiotensin I and human gastrin I complement their positive fast atom bombardment spectra. Negative xenon fast atom bombardment spectra of underivatized peptides exhibit molecular proton-abstracted ion envelopes and structurally significant fragment ions. Peptide mixture analysis under negative xenon fast atom bombardment reveals peptide molecular ion envelopes of higher relative intensities than under positive xenon fast atom bombardment.  相似文献   

14.
Acidic glycosphingolipids were analyzed by field desorption (FD-MS) and secondary ion mass spectrometry (SI-MS) using the primary ion Xe+ with a glycerol matrix. In the analysis of underivatized gangliosides by FD-MS, the fragment corresponding to the asialo residue resulting from the cationized cluster ion (M + Na)+ was the base peak, and ions due to cleavage at the glycosidic linkages were detected, as in the neutral glycosphingolipids. In the case of sulfatide, the ceramide fragment showed the highest intensity in the spectrum. In SI-MS spectra of acidic glycosphingolipids, (M + Na)+, (M + 2Na-H)+, and (M + K)+ were continuously detected as relatively high intensity ions during analysis of gangliosides and sulfatide. Other ions were mostly similar to those obtained by FD-MS. In FD-MS spectra of permethylated gangliosides, the cationized molecular ion (M + Na)+ was the base peak, and fragment ions due to asialo gangliosides were prominent. Other peaks were hard to detect. In SI-MS, molecular ions (M + H)+ and (M + H-32)+ and other ions due to cleavage of the glycosidic linkages were clearly detected. In this case, the sensitivity was greatly improved. Ions due to the non reducing end sugars were clearly detected, because of the relatively low intensity of ion peaks due to the glycerol matrix. It is concluded that the combination with FD-MS and SI-MS is particularly useful for the determination of molecular weight, sugar sequence and ceramide structure with sample amounting to only a few micrograms order.  相似文献   

15.
Twelve naturally occurring glucosinolates displaying alkenyl, hydroxylated, methylsulphinyl, aromatic and indole side chains were investigated by both negative and positive ion electrospray ionisation-tandem mass spectrometry (ESI-MS/MS). In order to resolve the MS/MS spectra obtained from the anion and cation molecular ions of glucosinolates, the different fragments were investigated by MSn experiments using an ion trap spectrometer. The MS3 spectra obtained permitted possible fragmentation schemes to be proposed. These were supported by accurate mass measurements of some characteristic diagnostic ions with the help of a quadrupole time-of-flight instrument. The negative ion ESI-MS/MS behaviour of the different glucosinolates investigated in this study confirmed previously described patterns and revealed new interesting structural informative fragments. Some are common to all the glucosinolates and others are highly specific for a type of variable side chain. The positive ion ESI-MS/MS fragments obtained from the [MNa+Na]+ or [MK+K]+ molecular ions did not provide complementary specific diagnostic ions. Nevertheless, when compared with the negative ion mode, the daughter ions appeared more homogenous and with a better relative abundance for all of the 12 compounds studied. Moreover, the positive ion mode appeared to be more efficient than the negative mode for the study of methoxylated glucosinolates and should be useful to detect the glucosinolates present as organic salts in crude plant extracts.  相似文献   

16.
A major limitation in identifying peptides from complex mixtures by shotgun proteomics is the ability of search programs to accurately assign peptide sequences using mass spectrometric fragmentation spectra (MS/MS spectra). Manual analysis is used to assess borderline identifications; however, it is error-prone and time-consuming, and criteria for acceptance or rejection are not well defined. Here we report a Manual Analysis Emulator (MAE) program that evaluates results from search programs by implementing two commonly used criteria: 1) consistency of fragment ion intensities with predicted gas phase chemistry and 2) whether a high proportion of the ion intensity (proportion of ion current (PIC)) in the MS/MS spectra can be derived from the peptide sequence. To evaluate chemical plausibility, MAE utilizes similarity (Sim) scoring against theoretical spectra simulated by MassAnalyzer software (Zhang, Z. (2004) Prediction of low-energy collision-induced dissociation spectra of peptides. Anal. Chem. 76, 3908-3922) using known gas phase chemical mechanisms. The results show that Sim scores provide significantly greater discrimination between correct and incorrect search results than achieved by Sequest XCorr scoring or Mascot Mowse scoring, allowing reliable automated validation of borderline cases. To evaluate PIC, MAE simplifies the DTA text files summarizing the MS/MS spectra and applies heuristic rules to classify the fragment ions. MAE output also provides data mining functions, which are illustrated by using PIC to identify spectral chimeras, where two or more peptide ions were sequenced together, as well as cases where fragmentation chemistry is not well predicted.  相似文献   

17.
Using photographic detection and high resolution, the potential of field desorption mass spectrometry for mixture analysis is exemplified by means of synthetic mixtures of up to 15 amino acid phenylthiohydantoins (PTH amino acids). The high molecular ion intensities, low fragmentation, and relatively small intermolecular interaction allow the easy discrimination of individual components of these mixtures. The sensitivity and selectivity of the field desorption method is tested on PTH amino acids obtained from automated Edman sequenator degradations of a ribosomal protein. The field desorption spectra show the molecular ions and significant fragment ions of the PTH derivatives of all 10 degradation steps investigated. Even in cases where conventional electron impact mass spectrometry fails to show the molecular ions and only characteristic fragment ions are found, the field desorption method gives rise to the molecular ions in high yields (e.g., PTH-arginine and PTH-(?-PTC)-lysine). Therefore the use of the method as a complementary technique for the confirmation of PTH amino acids released in the Edman sequenator appears to be advantageous.  相似文献   

18.
Methane chemical ionization spectra of acetylated and perdeutero-acetylated ceramides, cerebrosides, and ceramide dihexosides have been analyzed and compared with electron impact ionization spectra of the same compounds. Abundant fragment ions for the loss of acetic acid from the protonated molecular ion in C.I. spectra readily enable the determination of the molecular weights of the principal species of sphingolipid mixtures. Complete structures can be elucidated by the combination of E.I. and C.I. mass spectra.  相似文献   

19.
Abstract

Electrospray mass spectra for selected modified deoxynucleosides and deoxynucleoside monophosphates have been determined. Protonated molecular ions are abundant in the positive ion spectrum, while (M-H) appears in the negative ion spectrum. However, fragment ion intensities are usually low in both spectra. Conditions which promote collision-induced dissociation within the electrospray source facilitate fragment ion formation, and the intensity of BH2 + and S+ (positive ion spectrum) and (M-BH) and B (negative ion spectrum) are enhanced by increasing the skimmer cone voltage. MH+ was detected with as little as 3 pmol of deoxynucleoside, and the protonated molecular ion intensity is linear with respect to analyte concentration over two orders of magnitude.  相似文献   

20.
In addition to protein identification, characterization of post-translational modifications (PTMs) is an essential task in proteomics. PTMs represent the major reason for the variety of protein isoforms and they can influence protein structure and function. Upon matrix-assisted laser desorption/ionization (MALDI) most post-translationally modified peptides form a fraction of labile molecular ions, which lose PTM-specific residues only after acceleration. Compared to fully accelerated ions these fragment ions are defocused and show in reflector mass spectra reduced resolution. A short time Fourier transform using a Hanning window function now uses this difference in resolution to detect the metastable fragments. Its application over the whole mass range yields frequency distributions and amplitudes as a function of mass, where an increased low frequency proportion is highly indicative for metastable fragments. Applications on the detection of metastable losses originating from carboxamidomethylated cysteines, oxidized methionines, phosphorylated and glycosylated amino acid residues are presented. The metastable loss of mercaptoacetamide detected with this procedure represents a new feature and its integration in search algorithms will improve the specificity of MALDI peptide mass fingerprinting.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号