1.
doi:10.1111/j.1741‐2358.2009.00356.x
Colour change of soft denture liners after storage in coffee and coke This study was to evaluate the colour change of soft denture liners after thermocycling and storage in coffee and coke. Four liners, two silicone‐based (Sofreliner S and Reline GS) and two acrylic resin‐based (Soft Confort and Dentuflex), were evaluated in this study. Ten samples were obtained for each group. After 2000 cycles of thermocycling with baths of 5°C and 55°C, five samples were stored in coffee and the remaining samples in coke. The colour alteration was evaluated in a reflection spectrophotometer before and after thermocycling, and after 1, 3, 24, 48 and 96 h of storage in coffee and coke. Data were submitted to anova and Tukey’s HSD test (α = 0.05). Thermocycling and storage period represented a higher statistically significant influence for the resin liners than for the silicone materials. Coke did not influence the colour stability of the materials during storage. However, the coffee solution generated statistically significant colour alteration in the material Soft Confort. In the comparison between the coffee and coke solutions, there was no statistically significant difference for colour alteration only for the material Dentuflex. The silicone liners presented better colour stability following thermocycling and storage independent of the solution. The coffee solution was a statistically significant factor for colour alteration of the material Soft Confort.  相似文献   

2.
doi: 10.1111/j.1741‐2358.2011.00487.x
Effect of sealer coating on mechanical and physical properties of permanent soft lining materials Objective: To evaluate the long‐term effects of sealer coating on tensile bond strength and surface roughness of soft liners. Background: Failure of the bond between resilient liners and denture base significantly compromise the dentures’ longevity. In addition, surface roughness contributes to bacterial adherence on prosthetic materials, increasing the risk of oral infections. Methods: Specimens were manufactured from four reliners [Mucopren Soft (MS), Dentuflex (DF); Soft Comfort Denso (SC) and Ufi Gel SC (USC)], distributed into 10 groups (n = 10), according to material and coating treatment. Tensile bond strength was performed after one year of ageing, while surface roughness was evaluated at 0, 1, 3, 6 and 12 ageing months. Bond strength data were submitted to two‐way anova and Tukey‐HSD tests, while roughness data were submitted to mixed model analysis for repeated measurements (p ≤ 0.05). Results: MS and DF without sealer coating presented the highest tensile bond strength. After coating, DF and SC presented increased tensile bond strength. No surface roughness difference was observed in the non‐coated groups over time, acrylic‐based reliners presented higher roughness. Among coated groups, only SC presented increased surface roughness. Acrylic‐based materials presented reduced roughness at three months. Conclusion: Surface coating was effective for acrylic reliners in maintaining their initial properties. However, sealer coating should be re‐applied every 3 months.  相似文献   

3.
doi:10.1111/j.1741‐2358.2009.00321.x
Flexural properties of repaired heat‐polymerising acrylic resin after wetting with monomer and acetone Objectives: Repair strength can be improved by treating fractured surfaces of a denture. Background: This study investigated flexural properties of heat‐polymerised acrylic resin specimens repaired with auto‐polymerising and visible light curing (VLC) resins after the repair surfaces were wetted with monomers or acetone. Materials and Methods: Fifty‐four specimens (65 × 10 × 2.5 mm) were prepared and 48 of them were sectioned to simulate denture fracture. Butt‐joint designed repair surfaces were wetted with heat‐, auto‐polymerising monomers and acetone for 180 s and repaired with auto‐polymerising and VLC resins. After repairs, specimens were subjected to three‐point bending test and flexural strength, strain, fracture load, modulus of elasticity and deflection values were recorded. Data were analysed with Student t and LSD tests (p ≤ 0.05). Results: Overall flexural strength, strain, fracture load and deflection values of specimens repaired with VLC resin were significantly higher than the specimens repaired with auto‐polymerising resin for all types of wetting agent (p < 0.05). Within the wetting agents, heat‐ and auto‐polymerising monomers produced the best mechanical properties, while wetting with acetone did not provide superior effect over both monomers. Conclusion: In clinical use, wetting the repair surfaces may result in stronger repairs. The use of bonding agent in VLC resin repairs in combination with wetting agent results in improved flexural properties.  相似文献   

4.
doi: 10.1111/j.1741‐2358.2010.00438.x Evaluation of experimental cleanser solution of Ricinus communis: effect on soft denture liner properties Objective: This study evaluated colour stability, hardness and roughness of soft denture liners after immersion in various cleansers. Materials and methods: Thirty specimens (14 mm × 4 mm) of Elite Soft Relining (ES) and Mucopren Soft (MS) were randomly immersed in distilled water at 37°C, sodium hypochlorite 1%, and an experimental Ricinus communis solution (RC) for 7, 15 and 183 continuous days. Results: anova (p < 0.05) and Tukey’s test indicated that after T7 (μ =8.79 ± 7.36); T15 (μ = 4.23 ± 2.62) and T183 (μ = 8.78 ± 3.16), MS presented a higher increase in hardness than ES. After T7, MS underwent an increase in roughness (μ = 0.09 ± 0.80); ES underwent a decrease (μ = ?0.08 ± 0.16). RC caused the smallest variation in roughness. After T15, both materials presented an increase in roughness. After T183, ES (μ = ?0.30 ± 0.48) presented a higher roughness variation than MS (μ = ?0.07 ± 0.32). Hypochlorite caused an increase in roughness (μ = 0.02 ± 0.19). Conclusion: After all periods ES presented higher colour alteration than MS; highest colour alteration was caused by hypochlorite. Both materials were more stable after immersion in RC.  相似文献   

5.
doi: 10.1111/j.1741‐2358.2010.00473.x
Influence of artificial accelerated ageing on the colour stability of paints used for ocular prosthesis iris painting Objectives: To evaluate the colour stability of paints used for ocular prosthesis iris painting submitted for accelerated artificial ageing (AAA). Materials and methods: Forty specimens of acrylic resin for sclera (16 × 2 mm) were made and separated into eight groups (n = 10) according to the type of paint (gouache, GP; oil, OP; acrylic AP; and composite resin for characterisation, CR) and the colours used (blue/brown). After drying (72 h), a new layer of colourless acrylic resin was applied and the initial colour readout was performed (Spectrophotometer PCB 6807). New colour readouts were performed after AAA, and ΔE was calculated. Results: Statistical analysis (two‐way anova –Bonferroni, p < 0.05) demonstrated that the brown colour showed lower ΔE means in comparison with the blue colour, with statistically significant difference for AP only. Blue colour showed no statistically significant difference with regard to the type of paint used. Brown AP showed lower ΔE than the other groups, with significant difference for OP and GP. GP showed greater alteration in ΔE for the brown colour, being statistically similar only to OP. Conclusions: Only the AP group for brown pigment shows clinically acceptable values for colour stability after AAA.  相似文献   

6.
doi: 10.1111/j.1741‐2358.2011.00485.x
Candida albicans biofilm formation on soft denture liners and efficacy of cleaning protocols Objective: The aim of this study was to investigate Candida albicans biofilm formation on denture liners and to analyse the efficacy of cleaning protocols. Material and methods: Specimens were prepared from four silicone‐based soft denture liners. After artificial ageing and surface free energy determination, specimens were incubated with saliva (2 h) and Candida albicans ATCC 10231 for either short‐ (2.5 h) or long‐term (24 h) biofilm formation. Adherent cells were determined either after incubation of specimens with Candida albicans or after treatment with different denture cleaning protocols. Statistical analysis was performed using one‐way anova and the Games–Howell test (α = 0.05). Results: For both short‐ and long‐term biofilm formation, similar amounts of Candida albicans cells were found on the surface of the different liners (p = 0.295 and 0.178, respectively). For both short‐ and long‐term biofilm formation, the highest cleaning efficacy was observed for sodium hypochlorite (NaOCl; p < 0.01). The efficacy of the chemical denture cleaner in removing long‐term Candida albicans biofilms was significantly lower than the efficacy of removal by brushing (p < 0.001). Conclusion: Different silicone‐based soft denture liners yield similar Candida albicans biofilm formation on their surface. The highest efficacy for the removal of Candida albicans biofilms was identified for NaOCl. Chemical denture cleaners appear to have rather low efficacy to remove mature Candida albicans biofilms.  相似文献   

7.
doi: 10.1111/j.1741‐2358.2010.00447.x
Effect of thermocycling on hardness, absorption, solubility and colour change of soft liners Objective: The effect of artificial ageing on the hardness, absorption, solubility, and colour of soft denture liners was investigated. Materials and methods: Liner materials based on acrylic resin (Trusoft) or silicone (Dentusil, Ufi Gel P, and Ufi Gel SC) were tested before and after 2000 thermal cycles. A total of 20 specimens of each material were tested. Half of the specimens were used for hardness and colour evaluation, and the remainder for absorption and solubility tests. The hardness evaluation was carried out using a Shore A durometer, while absorption and solubility tests were performed by storing samples in a desiccator and weighing daily until reaching constant mass (W1). After thermocycling, the samples were again weighed (W2) and dried (W3). Colour was measured using a spectrophotometer. Statistical analysis was performed using GraphPad InStat at the p < 0.05 level. Results: Thermocycling significantly affected the hardness of the specimens. The Trusoft material exhibited the highest absorption (1.48 ± 0.48), solubility (1.26 ± 0.28), and colour change (3.92 ± 0.33), significantly different from the other materials. There were no significant differences among the silicones in terms of absorption, solubility, and colour change, except for the colour of Dentusil, which changed (0.83 ± 0.11). Conclusion: It can be concluded that silicone liners performed significantly better compared to acrylic resin.  相似文献   

8.
Gerodontology 2010; doi: 10.1111/j.1741‐2358.2010.00375.x Surface changes in denture soft liners with and without sealer coating following abrasion with mechanical brushing Aim: To evaluate the surface alterations of soft liners with or without sealer coating following abrasion with mechanical brushing. Methods: Thirty specimens were made of a methacrylate‐ (Coe‐Soft) and a siloxane‐based material (Ufi‐Gel SC), and 15 received two coatings of surface sealer. The specimens were submitted to a mechanical brushing‐dentifrice assay under 200 g of force at 250 cycles/min. Mechanical brushing was simulated for a period of 1 (1250 cycles) and 6 months (5000 cycles). Surface roughness (Ra parameter) was measured, and scanning electron microscopy (SEM) images were obtained. Ra data were analysed by anova for repeated measures and Bonferroni’s test (alpha = 0.05). Results: Ra increased from baseline to 6 months regardless of sealer coating. At baseline, only Coe‐Soft without sealer had a higher Ra than the other groups. After 1 month, the Ra of Coe‐Soft with sealer was three‐fold higher than the Ra at baseline; the other groups showed no significant increase of Ra. SEM images showed degradation of the soft liners over time, except for the Ufi‐Gel SC with sealer, which displayed minimum alteration of surface texture. Conclusion: Sealer coating reduced the surface degradation of the tested soft liners, but the protective effect was more pronounced for the siloxane‐based material.  相似文献   

9.
doi: 10.1111/j.1741‐2358.2011.00503.x Oral health related quality of life of edentulous patients after denture relining with a silicone‐based soft liner Background: Knowledge of benefits caused by a treatment on quality of life is very relevant. Despite the wide use and acceptance of soft denture liners, it is necessary to evaluate the patient’s response about the use of these materials with regard to improvement in oral health related quality of life (OHRQoL). Objectives: The aim of this study was to evaluate the influence of denture relining in the OHRQoL of edentulous patients. Materials and methods: Thirty‐two complete denture wearers had their lower dentures relined with a silicone‐based material (Mucopren soft, Kettenbach, Germany) according to chairside procedures. OHRQoL was assessed before and after 3 months of relining by means of OHIP‐EDENT, and the median scores were compared by Wilcoxon test (p ≤ 0.05). Results: After 3 months of relining, participants reported significant improvement of their OHRQoL (p ≤ 0.01). Conclusion: Denture relining with a soft liner may have a positive impact on the perceived oral health of edentulous patients.  相似文献   

10.
doi: 10.1111/j.1741‐2358.2011.00515.x Flexural and bond strengths of relined denture polymers assessed by four‐point bending tests and Weibull analysis Objectives: The aim of this study was to (1) investigate the flexural strengths of three denture resins i.e. heat, photopolymerised and microwaved and how it was affected by relining with auto‐ and visible light–polymerised hard reliners, (2) investigate the bond strengths between denture resins and hard reliners and (3) interpret the results of both tests by utilising Weibull analysis. Materials and methods: Specimens (65 × 10 × 2.5 mm) from denture resins, relined and bonded combinations were tested using a four‐point bending test in a universal testing machine and a crosshead speed of 5 mm/min. Ten specimens for each bulk resin and denture resin–reliner combination for a total of 150 were tested. Results: Statistical analysis indicated significant differences between bulk materials (p < 0.001) and between reliners (p < 0.001) for flexural and bond strength tests. Conclusion: It was concluded that (1) the four‐point flexural strength was different between the denture base materials, (2) flexure strength between bulk and relined or between relined with autopolymerised and photopolymerised bases was different, (3) flexural strength among relined denture bases was different and (4) bond strengths among relined denture bases were different.  相似文献   

11.
doi: 10.1111/j.1741‐2358.2010.00419.x
Effect of accelerated ageing and surface sealing on the permanent deformation of auto‐polymerising soft linings Purpose: To compare the effects of different ageing methods on the permanent deformation of two permanent soft liners. Materials and methods: The materials selected were auto‐polymerising acrylic resin and silicone‐based reliners. Sealer coating was also evaluated. Sixty specimens of each reliner were manufactured (12.7 mm diameter and 19 mm length). Specimens were randomly distributed into 12 groups (n = 10) and submitted to one of the accelerated ageing processes. Permanent deformation tests were conducted with a mechanical device described within the American Dental Association specification number 18 with a compressive load of 750 gf applied for 30 s. All data were submitted for statistical analysis. Mann–Whitney test compared the effect of the surface sealer on each material and the permanent deformation of the materials in the same ageing group (p = 0.05). Kruskal–Wallis and Dunn tests compared all ageing groups of each material (p = 0.05). Results: The silicone‐based reliner presented a lower permanent deformation than the acrylic resin‐based reliner, regardless of the ageing procedure. The surface sealer coating was effective only for the thermocycled silicone group and the accelerated ageing processes affected only the permanent deformation of the acrylic resin‐based material. Conclusion: The silicone‐based reliner presented superior elastic properties and the thermocycling was more effective in ageing the materials.  相似文献   

12.
doi: 10.1111/j.1741‐2358.2012.00658.x Survival analysis of mandibular complete dentures with acrylic‐based resilient liners Objective: The purpose of this long‐term randomised controlled trial was to compare the longevity of dentures constructed using a conventional acrylic resin (CAR) to that of dentures constructed using an acrylic‐based resilient liner (ARL). Materials and methods: The follow‐up study was essentially carried out by annual telephone calls to each of the 67 participants. The Kaplan–Meier method and life‐table analysis were used for univariate analyses. The Cox proportional‐hazards test was used as a final model for statistically adjusting predictor variables such as sex, clinician type, mandibular denture type and age at denture delivery. Results: The denture type was likely to affect the survival time of the dentures, while the sex and clinician type were not. The group using acrylic‐based resilient denture liners had twice the risk of having shorter denture‐survival times than those using conventional acrylic resin dentures. Younger participants were likely to have a reduced risk of having shorter denture‐survival times than older participants. Conclusion: We conclude that mandibular complete dentures constructed using ARL are twice as likely as dentures constructed using CAR to have shorter denture survival times, mainly because of material deterioration.  相似文献   

13.
doi:10.1111/j.1741‐2358.2009.00359.x
The prevalence of denture stomatitis and its predisposing conditions in an older Greek population Background: Pathology related to complete denture‐wearing will remain an important issue because of an increase in the ageing population. Objective: To investigate the prevalence and the risk factors for denture‐related stomatitis in the edentulous maxilla of older patients with a maxillary complete denture. Material and methods: One hundred and six patients treated in the Department of Prosthodontics of the Athens Dental School were interviewed and clinically examined. The results were analysed using chi‐square tests and multiple logistic regression. Results: Denture stomatitis was recorded in 39.6% of the sample (pinpoint hyperaemia: 17%, diffuse erythema: 16%, papillary hyperplasia: 6.6%). Chi‐square tests recorded significant associations between denture stomatitis and the continuous use of dentures (particularly the diffuse erythema type), the increased duration of denture experience and the poor retention of the maxillary denture. Other significant associations were recorded between the increased age of the current denture and pinpoint hyperaemia, and the reduced frequency of denture cleaning and papillary hyperplasia. Multiple logistic analysis revealed that the most important risk factor for denture stomatitis was the continuous use of the denture. Conclusion: The prevalence of denture stomatitis was high in denture users. Although many predisposing conditions were recorded, the most important risk factor was the continuous use of the denture. Therefore, appropriate advice on denture maintenance should be provided.  相似文献   

14.
Background: Soft denture lining‐materials are more susceptible to microbial adhesion than hard denture base acrylic resin. Poor oral hygiene and Candida albicans infection are common among elderly denture wearers as these patients usually have difficulty in keeping them clean. Purpose: To evaluate the influence of the oral hygiene methods on the formation of a biofilm over a soft denture‐lining material. Material and methods: Twenty volunteers were randomly separated into two groups: G1 and G2. Ten volunteers performed daily hygiene of the prostheses with a soft toothbrush and toothpaste. The G2 performed a treatment identical to G1 but also immersed the prostheses in sodium hypochlorite 0.5% for 20 min, once a week. Quantification of the mean score values of biofilm formation at different times were statistically analysed using analysis of variance and Tukey’s test (α = 0.05). Results: G1 (0.65 ± 0.52) showed the lowest mean score values of biofilm formation. There was statistical difference between G1 and G2. The highest mean score values were found at 6 weeks (1.3 ± 1.08) and were statistically different from other times. Conclusion: The oral hygiene methods had a significant effect in the formation of the biofilm over a soft denture‐lining material.  相似文献   

15.
doi:10.1111/j.1741‐2358.2009.00347.x
Reliability of a method for evaluating porosity in denture base resins Background: The method of porosity analysis by water absorption has been carried out by the storage of the specimens in pure water, but it does not exclude the potential plasticising effect of the water generating unreal values of porosity. Objective: The present study evaluated the reliability of this method of porosity analysis in polymethylmethacrylate denture base resins by the determination of the most satisfactory solution for storage (S), where the plasticising effect was excluded. Materials and methods: Two specimen shapes (rectangular and maxillary denture base) and two denture base resins, water bath‐polymerised (Classico) and microwave‐polymerised (Acron MC) were used. Saturated anhydrous calcium chloride solutions (25%, 50%, 75%) and distilled water were used for specimen storage. Sorption isotherms were used to determine S. Porosity factor (PF) and diffusion coefficient (D) were calculated within S and for the groups stored in distilled water. anova and Tukey tests were performed to identify significant differences in PF results and Kruskal–Wallis test and Dunn multiple comparison post hoc test, for D results (α = 0.05). Results: For Acron MC denture base shape, FP results were 0.24% (S 50%) and 1.37% (distilled water); for rectangular shape FP was 0.35% (S 75%) and 0.19% (distilled water). For Classico denture base shape, FP results were 0.54% (S 75%) and 1.21% (distilled water); for rectangular shape FP was 0.7% (S 50%) and 1.32% (distilled water). FP results were similar in S and distilled water only for Acron MC rectangular shape (p > 0.05). D results in distilled water were statistically higher than S for all groups. Conclusions: The results of the study suggest that an adequate solution for storing specimens must be used to measure porosity by water absorption, based on excluding the plasticising effect.  相似文献   

16.
doi: 10.1111/j.1741‐2358.2012.00657.x The effect of immersion cleansers on gloss, colour and sorption of acetal denture base material Objective: To study the effect of peroxide and hypochlorite cleansers on gloss, colour and sorption of acetal denture resins. Materials and methods: Pink acetal and thermoplastic acrylic resins were evaluated. Thirty‐five specimens 39 × 39 × 1.8 mm of each resin were prepared. Each group of specimens (n = 7) was then immersed into cleansers for 100 days. Group I immersed in tap water, Group II in Corega Extradent for 5 min, Group III in Corega Extradent for 8 h, Group IV in NitrAdine? Seniors for 15 min and Group V in NaOCl 5.25%. Gloss, colour and weight measurements were taken initially and after 100 days. Data subjected to two‐way anova and Tukey’s test at α = 0.05. Results: Acrylic resin showed reductions of glossiness from ?5 to ?15 and acetal from ?0.2 to ?6. Colour changes (ΔΕ*) ranged from 2.64 to 7.64 for acrylic and 2.77 to 26.54 for acetal resin. Sorption for acrylic ranged from 11.64 to 17.06 μg/mm3 and 9.18 to 24.79 μg/mm3 for acetal resin. The results of (ΔΕ*) and sorption showed an interaction between denture resins and cleansers. Conclusions: The gloss of acetal resin was less affected by water, peroxides and NaOCl 5.25% compared with acrylic resin. Acetal resin showed clinically acceptable (ΔΕ*) whereas acrylic resin unacceptable ones for water and peroxide solutions. The immersion of acetal resin in NaOCl 5.25% showed clinically unacceptable (ΔΕ*) and higher sorption and should be avoided or should be managed with care.  相似文献   

17.
Objective: This study aimed at describing the masticatory handicap of wearing removable dentures measured by some masticatory tests and the intake of hard and soft foods. Materials and methods: The subjects were participants in a comprehensive health examination of 67–68‐year‐old men living in Malmö, Sweden. Four hundred eighty‐three men took part in a clinical oral examination which recorded the number of teeth and removable dentures. One hundred and one had complete dentures in both jaws and 131 had removable partial dentures in different combinations. Masticatory tests used almonds to record the number of stokes to the first swallow, and two‐coloured chewing gums for recording bolus kneading and shaping. A nutritionist paid a home visit to assess dietary habits including the consumption of hard and soft foods. The data could be split into groups of different tooth and denture situations which were large enough to enable statistical analysis to be carried out. The results of a regression analysis of the group with different numbers of natural teeth (NT) and no removable dentures could be used as a reference for correlation with the masticatory capacity of removable denture wearers. Results: Number of strokes to the first swallow revealed no masticatory limitations of wearing removable dentures, while chewing gum colour‐mixing and shaping revealed more differentiated impairments equivalent to the function of five to 16 teeth in a remaining natural dentition. Hard food intake for the removable denture groups was comparable to 17–19 NT. Soft food intake was not influenced by denture wearing. In a ranking of oral conditions, those with more than 24 NT had the highest test values for all tests, and those with complete sets of dentures the lowest except for the number of strokes to the first swallow of an almond. Conclusion: Removable denture wearing can be regarded as a handicap when measured with objective masticatory tests using chewing gum and the intake of hard foods. The number of chewing strokes to the first swallow of an almond and the intake of soft foods is not affected by the wearing of removable dentures.  相似文献   

18.
doi:10.1111/j.1741‐2358.2009.00332.x
Effect of thermal cycling on microleakage between hard chairside relines and denture base acrylic resins Objectives: Microleakage is a pre‐stage of debonding between hard chairside relines and denture base acrylic resins. Therefore, it is important to assess them with regard to the longevity of the relined denture. This study investigated the effect of thermal cycling on the microleakage at the interface of three hard chairside reline resins and three denture base resins. Material and methods: Rectangular bars (12 mm × 3 mm × 3 mm) of Lucitone 550, Acron MC and QC 20 were made and relined with Kooliner, Tokuyama Rebase Fast II and Ufi Gel Hard, Lucitone 550, Acron MC and QC 20 resins. Specimens were divided into one control and two test groups (n = 10). In specimens of the control group, the microleakage was performed after the reline procedure. In Test Group 1, the specimens were stored for 24 h in distilled water at room temperature and in Test Group 2; the specimens were thermal cycled from 5 to 55°C for 5000 cycles with a 30‐s dwell time. Subsequently, all specimens were immersed in 50% silver nitrate solutions for 24 h. All specimens were sectioned longitudinally into three fractions and the lateral sections were examined (n = 20). Silver nitrate stain penetration was examined under a stereoscopic lens with ×30 magnification, and the images were captured. Leica Qwin image analysis software was used to determine microleakage at the interface of the materials. Data were analysed using the Kruskal–Wallis test at a 95% level of significance. Results: For all cycles, there were no statistically significant differences between thermal cycled and non‐thermal cycled groups (p > 0.05). Conclusion: It can be concluded that thermal cycling had no effect on the microleakage.  相似文献   

19.
Objective: The aim of the present study was to evaluate the in vitro biocompatibility of denture relining materials using cell culture tests and a test for irritation mechanisms. Background: Denture relining materials contain non‐reacted constituents that may leach out during use inducing local toxic or irritative effects. Materials and methods: One chemically cured, four visible light cured and five dual‐cured products were included. Cured test specimens were used for the filter diffusion test, and extracts of cured specimens were applied in the MTT and the irritation test using the hen's egg test‐chorioallantoic membrane (HET‐CAM) method. Results: Five of the tested materials were slightly or moderately cytotoxic in the filter diffusion test, and one product coated with a liner induced severe toxicity. Cell cultures incubated for 24 hour with the test samples were more damaged than those incubated for 2 hour. In the MTT test, extracts of nine of the 11 products induced cytotoxicity. No extracts showed irritation, whereas the coating and two bonding agents tested were strong irritants. Conclusion: Most of the tested materials contained water soluble, toxic substances that leach out of the products and that some time was needed to obtain cytotoxic amounts of the leachables. Many dental materials elicit cytotoxic response, but this does not necessarily reflect the long‐term risk for adverse effects as the oral mucosa is generally more resistant to toxic substances than a cell culture.  相似文献   

20.
doi: 10.1111/j.1741‐2358.2011.00520.x The effect of long‐term disinfection procedures on hardness property of resin denture teeth Objective: The aim of the study was to evaluate the effect of long‐term disinfection procedures on the Vickers hardness (VHN) of acrylic resin denture teeth. Material and methods: Five acrylic resin denture teeth (Vipi Dent Plus‐V, Trilux–T, Biolux‐B, Postaris‐P and Artiplus‐A) and one composite resin denture teeth (SR‐Orthosit‐O) were embedded in heat‐polymerised acrylic resin within polyvinylchloride tubes. Specimens were stored in distilled water at 37°C for 48 h. Measurements of hardness were taken after the following disinfection procedures: immersion for 7 days in 4% chlorhexidine gluconate or in 1% sodium hypochlorite (CIm and HIm group, respectively) and seven daily cycles of microwave sterilisation at 650 W for 6 min (MwS group). In the WIm group, specimens were maintained in water during the time used to perform the disinfection procedures (7 days). Data were analysed with anova followed by the Bonferroni procedure (α = 0.01). Results: Microwave disinfection decreased the hardness of all acrylic resin denture teeth (p < 0.001). Immersion for 7 days in 4% chlorhexidine gluconate or distilled water had significant effect on the hardness of the acrylic resin denture teeth A (p < 0.01), and 1% sodium hypochlorite on teeth T (p < 0.01). All disinfection procedures decrease the hardness of the composite resin denture teeth (p < 0.01). Teeth O exhibited the highest and teeth V the lowest hardness values in the control group (p < 0.01). Conclusions: Disinfection procedures changed the hardness of resin denture teeth.  相似文献   