首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We describe the preparation and characterization of a novel type of core-shell hybrid material for application in a novel hydrogen peroxide biosensor, where the structure consists of a continuous gold shell that encapsulates the silica fiber. The SiO(2)@Au nanofibers had been synthesized by electrospinning silica sol, and then golden seeds were in situ grown on the fiber, lastly the gold-seeded silica fibers were further coated by continuous gold shells. The above nanocomposites had satisfactory chemical stability, excellent biocompatibility and efficient electron transfer property, which may have potential application for the highly sensitive chemical or biological sensors. Cyclic voltammetry (CV) was used to evaluate the electrochemical performance of the SiO(2)@Au nanocomposites at indium tin oxide (ITO). The biosensor showed high sensitivity and fast response upon the addition of H(2)O(2) and the linear range to H(2)O(2) was from 5×10(-6) to 1.0×10(-3)M with a detection limit of 2 μM (S/N=3). The apparent Michaelis-Menten constant of the biosensor was 1.11 mmol L(-1). These results indicated that SiO(2)@Au nanocomposites have potential for constructing of a variety of electrochemical biosensors.  相似文献   

2.
Electrochemiluminescence (ECL) of TiO(2) nanocrystals with different crystal styles modified fluorine-doped tin oxide (FTO) electrode was investigated in H(2)O(2) solution. The amorphous TiO(2) nanospheres were facilely synthesized by the hydrothermal and condensation method. Crystal TiO(2), namely anatase and rutile, were prepared by calcination of the amorphous TiO(2) nanospheres at 450 and 800°C, respectively. The transmission electron microscope (TEM) and electron diffraction pattern were used to characterize the obtained TiO(2) nanoparticles morphology and the corresponding crystal styles. The electrochemical and ECL behaviors were investigated by cyclic voltammetry. The ECL quenching was observed by introduction of gold nanoparticles. Based on the quenching effect, a sensitive glucose ECL biosensor as a model was fabricated by in-situ growing-up gold seeds in AuCl(4)(-) solution induced by biologically generated H(2)O(2). The linear range to detect glucose is from 5.0×10(-7)M to 4.0×10(-3)M with the limit of detection of 2.5×10(-7)M.  相似文献   

3.
This paper introduces the use of multi walled carbon nanotubes (MWCNTs) with palladium (Pd) nanoparticles in the electrocatalytic reduction of hydrogen peroxide (H(2)O(2)). We have developed and characterized a biosensor for H(2)O(2) based on Nafion(?) coated MWCNTs-Pd nanoparticles on a glassy carbon electrode (GCE). The Nafion(?)/MWCNTs-Pd/GCE electrode was easily prepared in a rapid and simple procedure, and its application improves sensitive determination of H(2)O(2). Characterization of the MWCNTs-Pd nanoparticle film was performed with transmission electron microscopy (TEM), Raman, and X-ray photoelectron spectroscopy (XPS). Cyclic voltammetry (CV) and amperometry (at an applied potential of -0.2V) measurements were used to study and optimize performance of the resulting peroxide biosensor. The proposed H(2)O(2) biosensor exhibited a wide linear range from 1.0 μM to 10 mM and a low detection limit of 0.3 μM (S/N=3), with a fast response time within 10s. Therefore, this biosensor could be a good candidate for H(2)O(2) analysis.  相似文献   

4.
Lu W  Luo Y  Chang G  Sun X 《Biosensors & bioelectronics》2011,26(12):4791-4797
In this paper, we report on the first preparation of well-defined SiO(2)-coated graphene oxide (GO) nanosheets (SiO(2)/GO) without prior GO functionalization by combining sonication with sol-gel technique. The functional SiO(2)/GO nanocomposites (F-SiO(2)/GO) obtained by surface functionalization with NH(2) group were subsequently employed as a support for loading Ag nanoparticles (AgNPs) to synthesize AgNP-decorated F-SiO(2)/GO nanosheets (AgNP/F-SiO(2)/GO) by two different routes: (1) direct adsorption of preformed, negatively charged AgNPs; (2) in situ chemical reduction of silver salts. The morphologies of these nanocomposites were characterized by transmission electron microscopy (TEM) and scanning electron microscopy (SEM). It is found that the resultant AgNP/F-SiO(2)/GO exhibits remarkable catalytic performance for H(2)O(2) reduction. This H(2)O(2) sensor has a fast amperometric response time of less than 2s. The linear range is estimated to be from 1×10(-4) M to 0.26 M (r=0.998) and the detection limit is estimated to be 4 × 10(-6) M at a signal-to-noise ratio of 3, respectively. We also fabricated a glucose biosensor by immobilizing glucose oxidase (GOD) into AgNP/F-SiO(2)/GO nanocomposite-modified glassy carbon electrode (GCE) for glucose detection. Our study demonstrates that the resultant glucose biosensor can be used for the glucose detection in human blood serum.  相似文献   

5.
Yang Z  Ren Y  Zhang Y  Li J  Li H  Hu XH  Xu Q 《Biosensors & bioelectronics》2011,26(11):4337-4341
A novel biosensor is developed based on immobilization of proteins on nanoflake-like SnS? modified glass carbon electrode (GCE). With glucose oxidase (GOD) as a model, direct electrochemistry of the GOD/nanoflake-like SnS? is studied. The prepared SnS? has large surface area and can offer favorable microenvironment for facilitating the electron transfer between protein and electrode surface. The properties of GOD/SnS? are characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), UV-vis spectroscopy, Fourier transform infrared spectroscopy (FTIR) and cyclic voltammetry (CV), respectively. The immobilized enzyme on nanoflake-like SnS? retains its native structure and bioactivity and exhibits a surface-controlled, reversible two-proton and two-electron transfer reaction with the apparent electron transfer rate constant (k(s)) of 3.68 s?1. The proposed biosensor shows fast amperometric response (8s) to glucose with a wide linear range from 2.5 × 10?? M to 1.1 × 10?3 M, a low detection limit of 1.0 × 10?? M at signal-to-noise of 3 and good sensitivity (7.6 ± 0.5 mA M?1 cm?2). The resulting biosensor has acceptable operational stability, good reproducibility and excellent selectivity and can be successfully applied in the reagentless glucose sensing at -0.45 V. It should be worthwhile noting that it opens a new avenue for fabricating excellent electrochemical biosensor.  相似文献   

6.
Ni doped SnO(2) nanoparticles (0-5 wt%) have been prepared by a simple microwave irradiation (2.45 GHz) method. Powder X-ray diffraction (XRD) and transmission electron microscopy (TEM) studies confirmed the formation of rutile structure with space group (P(42)/mnm) and nanocrystalline nature of the products with spherical morphology. Direct electrochemistry of horseradish peroxidase (HRP)/nano-SnO(2) composite has been studied. The immobilized enzyme retained its bioactivity, exhibited a surface confined, reversible one-proton and one-electron transfer reaction, and had good stability, activity and a fast heterogeneous electron transfer rate. A significant enzyme loading (3.374×10(-10) mol cm(-2)) has been obtained on nano-Ni doped SnO(2) as compared to the bare glassy carbon (GC) and nano-SnO(2) modified surfaces. This HRP/nano-Ni-SnO(2) film has been used for sensitive detection of H(2)O(2) by differential pulse voltammetry (DPV), which exhibited a wider linearity range from 1.0×10(-7) to 3.0×10(-4)M (R=0.9897) with a detection limit of 43 nM. The apparent Michaelis-Menten constant (K(M)(app)) of HRP on the nano-Ni-SnO(2) was estimated as 0.221 mM. This excellent performance of the fabricated biosensor is attributed to large surface-to-volume ratio and Ni doping into SnO(2) which facilitate the direct electron transfer between the redox enzyme and the surface of electrode.  相似文献   

7.
A new highly catalytic and intensely sensitive amperometric sensor based on PtM (where M=Pd, Ir) bimetallic nanoparticles (NPs) for the rapid and accurate estimation of hydrogen peroxide (H(2)O(2)) by electrooxidation in physiological conditions is reported. PtPd and PtIr NPs-decorated multiwalled carbon nanotube nanocatalysts (PtM/MWCNTs) were prepared by a modified Watanabe method, and were characterized by XRD, TEM, ICP, and XAS. The sensors were constructed by immobilizing PtM/MWCNTs nanocatalysts in a Nafion film on a glassy carbon electrode. Both PtPd/MWCNTs and PtIr/MWCNTs assemblies catalyzed the electrochemical oxidation of H(2)O(2). Cyclic voltammetry characterization measurements revealed that both the PtM (M=Pd, Ir)/MWCNTs/GCE possessed similar electrochemical surface areas (~0.55 cm(2)), and electron transfer rate constants (~1.23 × 10(-3)cms(-1)); however, the PtPd sensor showed a better performance in H(2)O(2) sensing than did the PtIr counterpart. Explanations were sought from XAS measurements to explain the reasons for differences in sensor activity. When applied to the electrochemical detection of H(2)O(2), the PtPd/MWCNTs/GC electrode exhibited a low detection limit of 1.2 μM with a wide linear range of 2.5-125 μM (R(2)=0.9996). A low working potential (0V (SCE)), fast amperometric response (<5s), and high sensitivity (414.8 μA mM(-1)cm(-2)) were achieved at the PtPd/MWCNTs/GC electrode. In addition, the PtPd/MWCNTs nanocatalyst sensor electrode also exhibited excellent reproducibility and stability. Along with these attractive features, the sensor electrode also displayed very high specificity to H(2)O(2) with complete elimination of interference from UA, AA, AAP and glucose.  相似文献   

8.
Here we report on a new approach for the electrochemical detection of hydrogen peroxide (H(2)O(2)) based on the co-immobilization of horseradish peroxidase and methylene blue on the functionalized carbon buckypaper supported by a titanium substrate. Cyclic voltammetry was used to study and optimize the performance of the resulting electrochemical biosensor. The proposed biosensor exhibited high analytical performance towards the quantification of H(2)O(2) at the physiological pH 7.4. Under optimized conditions, the biosensor shows a wide linear response range from 0.1 × 10(-6) to 5 × 10(-4)M concentrations of H(2)O(2). The detection limit was determined to be 7.5 × 10(-8)M (based on S/N=3). Reproducibility and stability of the fabricated biosensor were examined with satisfactory results. The biological relevance of the developed electrochemical biosensor has been further studied by the determination of H(2)O(2) in human urine samples of normal volunteers prior to and following the ingestion of coffee. Increased levels of urinary H(2)O(2) concentration suggest that oxidative stress is induced by coffee drinking in humans. There is considerable interest in oxidative stress as relates to human physiology. The sensitive determination of H(2)O(2) in human urine may serve as a valuable biomarker to effectively elucidate specific levels of oxidative stress in vivo.  相似文献   

9.
A novel organic-inorganic nanocomposite of methylene blue (MB) and silicon oxide was synthesized and characterized by TEM, FTIR, and UV-vis. The as-prepared material was able to transfer the electron of the MB to electrode and was different from other SiO2 spheres structurally. It can be used as mediator to construct a biosensor with horseradish peroxidase (HRP) coimmobilized in the gelatine matrix and cross-linked with formaldehyde. The resulting biosensor exhibited fast amperometric response and good stability to hydrogen peroxide (H2O2). The linear range for H2O2 determination was from 1 x 10(-5) to 1.2 x 10(-3) M, with a detection limit of 4 x 10(-6) M based on S/N = 3. Moreover, the lifetime is more than 3 months under dry conditions at 4 degrees C.  相似文献   

10.
The nanocomposite composed of carboxymethyl chitosan (CMCS) and gold nanoparticles was successfully prepared by a novel and in situ process. It was characterized by transmission electron microscopy (TEM) and Fourier transform infrared spectrophotometer (FTIR). The nanocomposite was hydrophilic even in neutral solutions, stable and inherited the properties of the AuNPs and CMCS, which make it biocompatible for enzymes immobilization. HRP, as a model enzyme, was immobilized on the silica sol-gel matrix containing the nanocomposite to construct a novel H(2)O(2) biosensor. The direct electron transfer of HRP was achieved and investigated. The biosensor exhibited a fast amperometric response (5s), a good linear response over a wide range of concentrations from 5.0 x 10(-6) to 1.4 x 10(-3)M, and a low detection limit of 4.01 x 10(-7)M. The apparent Michaelis-Menten constant (K(M)(app)) for the biosensor was 5.7 x 10(-4)M. Good stability and sensitivity were assessed for the biosensor.  相似文献   

11.
The biocatalytic growth of gold nanoparticles (Au-NPs) has been employed in the design of new optical biosensors based on the enhanced resonance light scattering (RLS) signals. Both absorption spectroscopy and transmission electron microscopy (TEM) analysis revealed Au-NP seeds could be effectively enlarged upon the reaction with H(2)O(2), an important metabolite that could be generated by many biocatalytic reactions. Upon the stepwise enlargement of Au-NPs, the light scattering intensity could be greatly enhanced, which then allowed the quantitative detection of the analyte, H(2)O(2). Further combination of the biocatalytic reaction that can yield H(2)O(2) by using the enzyme, glucose oxidase, with the enlargement of Au-NPs enabled the design of a sensitive glucose biosensor using the RLS technique. In the present study, we could achieve the detection of glucose in a linear range of 1.0 x 10(-6) M to 1.1 x 10(-4) M, with detection limit of 6.8 x 10(-7) M.  相似文献   

12.
Xian Y  Hu Y  Liu F  Xian Y  Wang H  Jin L 《Biosensors & bioelectronics》2006,21(10):1996-2000
In this paper, we report a novel glucose biosensor based on composite of Au nanoparticles (NPs)-conductive polyaniline (PANI) nanofibers. Immobilized with glucose oxidase (GOx) and Nafion on the surface of nanocomposite, a sensitive and selective biosensor for glucose was successfully developed by electrochemical oxidation of H2O2. The glucose biosensor shows a linear calibration curve over the range from 1.0x10(-6) to 8.0x10(-4) mol/L, with a slope and detection limit (S/N=3) of 2.3 mA/M and 5.0x10(-7) M, respectively. In addition, the glucose biosensor system indicates excellent reproducibility (less than 5% R.S.D.) and good operational stability (over 2 weeks).  相似文献   

13.
A highly sensitive and selective amperometric hydrogen peroxide (H(2)O(2)) biosensor based on immobilization of hemoglobin (Hb) at multiwalled carbon nanotubes-zinc oxide (MWCNT/ZnO) composite modified glassy carbon electrode (GCE) is reported. ZnO microsponges were electrochemically grown on MWCNT surface by the simple, cost-effective, green, electrochemical method at room temperature. The MWCNT/ZnO/Hb composite film showed a pair of well-defined, quasi-reversible redox peaks with a formal potential (E°') of -0.336V, characteristic features of heme redox couple of Hb. The electron transfer rate constant (k(s)) of immobilized Hb was 1.26s(-1). The developed biosensor showed a very fast response (>2s) toward H(2)O(2) with good sensitivity, wide linear range, and low detection limit of 0.02μM. The fabricated biosensor showed interesting features, including high selectivity, acceptable stability, good reproducibility, and repeatability along with excellent conductivity, facile electron mobility of MWCNT, and good biocompatibility of ZnO. The fabrication method of this biosensor is simple and effective for determination of H(2)O(2) in real samples with quick response, good sensitivity, high selectivity, and acceptable recovery.  相似文献   

14.
Polyoxometalates (H(3)PW(12)O(40), H(4)SiW(12)O(40) and H(3)PMo(12)O(40)) have been proven to possess intrinsic peroxidase-like activity for the first time, which can catalyze oxidation of the peroxidase substrate 3,3',5,5'-tetramethylbenzidine (TMB) by H(2)O(2) to form a blue color in aqueous solution. Among them, H(3)PW(12)O(40) (PW(12)) exhibits higher catalytic activity to TMB than natural enzyme HRP and other two POMs. In addition, H(3)PW(12)O(40)/graphene exhibited higher activity than H(3)PW(12)O(40) in this catalytic oxidation reaction due to the effect of graphene in promoting the electron transfer between the substrate and catalyst. POMs/H(2)O(2)/TMB system provides a simple, accurate approach to colorimetric detection for H(2)O(2) or glucose. The colorimetric method based on POMs showed good response toward H(2)O(2) and glucose detection with a linear range from 1.34×10(-7) to 6.7×10(-5) mol/L and 1×10(-7) to 1×10(-4) mol/L, respectively. The results showed that it is a simple, cheap, more convenient, highly selective, sensitive, and easy handling colorimetric assay.  相似文献   

15.
A simple and controllable electrodeposition approach was established for one-step construction of hydrogen peroxide (H(2)O(2)) biosensors by in situ formation of chitosan-ionic liquid-horseradish peroxidase (CS-IL-HRP) biocomposite film on electrode surface. A highly porous surface with orderly three-dimensional network was revealed by scanning electron microscopy (SEM) investigation. The biocomposite provided improved conductivity and biocompatible microenvironment. The developed biosensor exhibited a fast amperometric response for the determination of H(2)O(2) and 95% of the steady-state current was obtained within 2s. The linear response of the developed biosensor for the determination of H(2)O(2) ranged from 6.0x10(-7) to 1.6x10(-4)M with a detection limit of 1.5x10(-7)M. Performance of the biosensor was evaluated with respect to possible interferences and a good selectivity was revealed. The fabricated biosensor exhibited high reproducibility and long-time storage stability. The ease of the one-step non-manual technique and the promising feature of biocomposite could serve as a versatile platform for the fabrication of electrochemical biosensors.  相似文献   

16.
A convenient and effective strategy for preparation nanohybrid film of multi-wall carbon nanotubes (MWNT) and gold colloidal nanoparticles (GNPs) by using proteins as linker is proposed. In such a strategy, hemoglobin (Hb) was selected as model protein to fabricate third-generation H2O2 biosensor based on MWNT and GNPs. Acid-pretreated, negatively charged MWNT was first modified on the surface of glassy carbon (GC) electrode, then, positively charged Hb was adsorbed onto MWNT films by electrostatic interaction. The {Hb/GNPs}n multilayer films were finally assembled onto Hb/MWNT film through layer-by-layer assembly technique. The assembly of Hb and GNPs was characterized with cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and transmission electron microscopy (TEM). The direct electron transfer of Hb is observed on Hb/GNPs/Hb/MWNT/GC electrode, which exhibits excellent electrocatalytic activity for the reduction of H2O2 to construct a third-generation mediator-free H2O2 biosensor. As compared to those H2O2 biosensors only based on carbon nanotubes, the proposed biosensor modified with MWNT and GNPs displays a broader linear range and a lower detection limit for H2O2 determination. The linear range is from 2.1x10(-7) to 3.0x10(-3) M with a detection limit of 8.0x10(-8) M at 3sigma. The Michaelies-Menten constant KMapp value is estimated to be 0.26 mM. Moreover, this biosensor displays rapid response to H2O2 and possesses good stability and reproducibility.  相似文献   

17.
In this paper, we have constructed a simple, rapid and sensitive biosensor for detection of choline and acetylcholine (ACh) based on the hydrogen peroxide (H(2)O(2))-sensitive quantum dots (QDs). The detection limit for choline was 0.1 μM and the linear range was 0.1-0.9 μM and 5-150 μM, respectively. The detection limit for ACh was found to be 10 μM and the linear range was 10-5000 μM. The wide linear ranges were shown to be suitable for routine analyses of choline and ACh. Possible mechanism of the fluorescence of QDs quenched by H(2)O(2) was an electron transfer (ET) process. The experimental conditions of biosensors were optimized, and anti-interference ability was also presented. We also detected the choline in milk samples and the linear range was 5-150 μM. The detection linear range of ACh in serum was 10-140 μM. Most importantly, the recovery of choline in milk and ACh in serum samples were both close to 99%. The excellent performance of this biosensor showed that the method can be used in practice detection of choline and ACh.  相似文献   

18.
S Wu  G Liu  P Li  H Liu  H Xu 《Biosensors & bioelectronics》2012,38(1):289-294
A novel and fast-fabricated Prussian blue (PB)/topological insulator Bi(2)Se(3) hybrid film has been prepared by coelectrodeposition technique. Taking advantages of topological insulator in possessing exotic metallic surface states with bulk insulating gap, Prussian blue nanoparticles in the hybrid film have smaller size as well as more compact structure, showing excellent pH stability even in the alkalescent solution of pH 8.0. Based on the Laviron theory, the electron transfer rate constant of PB/Bi(2)Se(3) hybrid film modified electrode was calculated to be 4.05±0.49s(-1), a relatively big value which may be in favor of establishing a high-sensitive biosensor. An amperometric glucose biosensor was then fabricated by immobilizing glucose oxidase (GOD) on the hybrid film. Under the optimal conditions, a wide linear range extending over 3 orders of magnitude of glucose concentrations (1.0×10(-5)-1.1×10(-2)M) was obtained with a high sensitivity of 24.55μAmM(-1) cm(-2). The detection limit was estimated for 3.8μM defined from a signal/noise of 3. Furthermore, the resulting biosensor was applied to detect the blood sugar in human serum samples without any pretreatment, and the results were comparatively in agreement with the clinical assay.  相似文献   

19.
The direct electron transfer of immobilized horseradish peroxidase (HRP) on silica-hydroxyapatite (HAp) hybrid film-modified glassy carbon electrode (GCE) and its application as H(2)O(2) biosensors were investigated. On silica/HRP-HAp/GCE, HRP displayed a fast electron transfer process accompanied with one proton participate in. This sensor exhibited an excellent electrocatalytic response to the reduction of H(2)O(2) without the aid of an electron mediator. The proposed biosensor showed good reproducibility and high sensitivity to H(2)O(2) with the detection limit of 0.35 microM. In the range of 1.0-100 microM, the catalytic reduction current of H(2)O(2) was proportional to H(2)O(2) concentration. The apparent Michaelis-Menten constant (k(m)(app)) of the biosensor was calculated to be 21.8 microM, exhibiting a high enzymatic activity and affinity for H(2)O(2).  相似文献   

20.
A sensitive and selective amperometric glucose biosensor based on platinum microparticles dispersed in nano-fibrous polyaniline (PANI) was investigated. Poly (m-phenylenediamine) (PMPD), which was employed as an anti-interferent barrier and a protective layer to platinum microparticles, was deposited onto platinum-modified PANI in the presence of glucose oxidase. The morphology of PANI, Pt/PANI and PMPD-GOD/Pt/PANI were investigated by scanning electron microscopy. The results show that PANI has a nano-fibrous morphology. The enzyme electrode exhibits excellent response performance to glucose with linear range from 2 x 10(-6) to 12 x 10(-3) M and fast response time within 7s. Due to the selective permeability of PMPD, the enzyme electrode also shows good anti-interference to uric acid and ascorbic acid. The Michaelis-Menten constant km and the maximum current density imax of the enzyme electrode were 9.34 x 10(-3) M and 917.43 microA cm(-2), respectively. Furthermore, this glucose biosensor also has good stability and reproducibility.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏