首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence (LIF) detection has been developed for a protein kinase assay. This protein kinase assay could readily determine the phosphorylation activity of substrate peptide kemptide using cAMP-dependent protein kinase (PKA) as a model enzyme. Kemptide and phosphorylated kemptide could be reacted with 7-fluoro-4-nitrobenzo-2-oxa-1,3-diazole (NBD-F) as a fluorescence derivatization reagent for LIF detection by directly adding NBD-F into the PKA enzymatic reaction mixture. These derivatives of substrate and product were separated and detected within the analysis time of 5 min by micellar electrokinetic mode using a mixture of sodium dodecylsulfate and methanol as a running buffer. Good linearity of the peak response of the phosphorylated kemptide was obtained over the range of 1-20 mU/tube of PKA in the assay. The relative standard deviation of the peak areas of the phosphorylated kemptide using 2, 5 and 10 mU/tube of PKA were calculated to <10.4%, indicating that the assay was reproducible. Also, IC(50) values of six PKA inhibitors, the K(i) value and the inhibition pattern of one inhibitor, which were calculated to estimate by the variation of the peak area of the phosphorylated kemptide using 5 mU/tube of PKA, were consistent with the published data. The sensitivity of the assay was higher than that of enzyme-linked immunosorbent assay (ELISA) for PKA phosphorylation activity, as IC(50) values, K(i) value, and the inhibition mechanism of inhibitors could be estimated using one-tenth amounts of PKA, compared with that of ELISA. The MEKC-LIF is expected to be very useful for protein kinase assay and its application to the estimation of inhibitors because this method does not entail experimentally troublesome procedures such as the preparation of antibody or fluorescence-labeled substrate.  相似文献   

2.
In the work, a label-free electrochemiluminescence (ECL) aptasensor for the sensitive and selective detection of thrombin was constructed based on target-induced direct ECL signal change by virtue of a novel assembly strategy of oligonucleotide and luminol functionalized gold nanoparticles (luminol-AuNPs). It is the first label-free ECL biosensor based on luminol and its analogs functionalized AuNPs. Streptavidin AuNPs coated with biotinylated DNA capture probe 1 (AuNPs-probe 1) were firstly assembled onto an gold electrode through 1,3-propanedithiol. Then luminol-AuNPs co-loaded with thiolated DNA capture probe 2 and thiolated thrombin binding aptamer (TBA) (luminol-AuNPs-probe 2/TBA) were assembled onto AuNPs-probe 1 modified electrode through the hybridization between capture probes 1 and 2. The luminol-AuNPs-probe 2/TBA acted as both molecule recognition probe and sensing interface. An Au/AuNPs/ds-DNA/luminol-AuNPs/TBA multilayer architecture was obtained. In the presence of target thrombin, TBA on the luminol-AuNPs could capture the thrombin onto the electrode surface, which produced a barrier for electro-transfer and influenced the electro-oxidation reaction of luminol, leading to a decrease in ECL intensity. The change of ECL intensity indirectly reflected the concentration of thrombin. Thus, the approach showed a high sensitivity and a wider linearity for the detection of thrombin in the range of 0.005-50nM with a detection limit of 1.7pM. This work reveals that luminol-AuNPs are ideal platform for label-free ECL bioassays.  相似文献   

3.
A composite of the metal–organic framework compound ZIF-8 doped with CdSe quantum dots (QDs) with sensitive and stable luminescence was synthesized, and a molecularly imprinted electrochemiluminescence (ECL) sensor was constructed based on this composite. The ZIF-8@CdSe molecularly imprinted ECL sensor combines the high sensitivity of ECL and the high selectivity of molecular imprinting to realize the sensitive and specific detection of estriol. CdSe QDs and gold nanoparticles were encapsulated within ZIF-8 to obtain the ZIF-8@CdSe QDs/GNP (ZIF@CdSe/GNP) composite. Subsequently, the GNPs were further loaded on the surface of this composite to obtain the GNP/ZIF@CdSe/GNP composite. l -Cysteine was used to immobilize the GNP/ZIF@CdSe/GNP composite on the surface of a gold electrode to obtain the GNP/ZIF@CdSe/GNP-modified gold electrode. A molecularly imprinted polymer (MIP) film was prepared on the surface of the modified electrode by electropolymerization with o-phenylenediamine as the functional monomer and estriol as the template molecule. After elution, estriol could be specifically recognized by the cavities. The readsorption of estriol by the MIP can prevent the coreactant from reaching the electrode surface through the cavities, thereby weakening ECL. A good linear relationship existed between the ∆ECL and lg C of estriol concentrations of 1 × 10−14 to 1 × 10−9 mol·L−1. The detection limit was as low as 8.9 × 10−16 mol·L−1. The sensor was applied in the determination of estriol in serum samples with a recovery of 97.0–102%.  相似文献   

4.
A novel electrogenerated chemiluminescence (ECL) biosensing method for highly sensitive detection of DNA methylation and assay of the CpG methyltransferase (M. SssI) activity was developed on basis of enzyme-linkage reactions and ruthenium complex served as an ECL tag. The ECL biosensing electrode was fabricated by self-assembling 5'-thiol modified 32-mer single-strand DNA (ss-DNA)-tagged with ruthenium bis (2,2'-bipyridine) (2,2'-bipyridine-4,4'-dicarboxylic acid)-ethylenediamine on the surface of a gold electrode, and then hybridized with complementary ss-DNA to form duplex DNA (ds-DNA). When M. SssI and S-adenosylmethionine were introduced, all cytosine residues within 5'-CG-3' of ds-DNA on the biosensing electrode were methylated. After the methylated biosensing electrode was treated by HpaII endonuclease, the un-methylated cytosines were cleaved, thus led to decrease ECL signal. The ECL intensity of ECL biosensing electrode is related to the methylation level and M. SssI activity in a fixed concentration HpaII endonuclease. The increased ECL intensity was direct proportion to M. SssI activity in the range from 0.05 to 100 U/mL with a detection limit of 0.02 U/mL. This work demonstrates that the combination of the enzyme-linkage reactions with a highly sensitive ECL technique is a great promising approach for the detection of DNA methylation level, assay of the activity of MTase, and evaluation of the capability of inhibitors for the methyltransferase.  相似文献   

5.
A novel procedure for detection and assay of protein kinase and phosphatase activities in complex biological mixtures was developed. By means of capillary zone electrophoresis (CZE) methodology, the phosphorylated and dephosphorylated forms of the peptide Kemptide, a 46-amino-acid fragment from protein phosphatase inhibitor-1 and a peptide fragment corresponding to the RII subunit of cAMP-dependent protein kinase (PKA), were rapidly resolved. This facilitated nonradioactive detection of PKA and protein phosphatase-2B (calcineurin) in rabbit skeletal muscle extracts. In addition, the CZE procedure enabled a site-specific assay of a 14-amino-acid peptide from the glycogen-binding subunit of protein phosphatase-1 monophosphorylated on distinct sites by PKA and casein kinase-II. These results suggest that CZE may prove to be extremely useful for the analysis of peptides that are phosphorylated at multiple sites in vivo.  相似文献   

6.
MicroRNAs (miRNAs), a kind of small, endogenous, noncoding RNAs (~22 nucleotides), might play a crucial role in early cancer diagnose due to its abnormal expression in many solid tumors. As a result, label-free and PCR-amplification-free assay for miRNAs is of great significance. In this work, a highly sensitive biosensor for sequence specific miRNA-21 detection without miRNA-21 labeling and enrichment was constructed based on the substrate electrode of dendritic gold nanostructure (DenAu) and graphene nanosheets modified glassy carbon electrode. Sulfydryl functionalized locked nucleic acid (LNA) integrated hairpin molecule beacon (MB) probe was used as miRNA-21 capture probe. After hybridized with miRNA-21 and reported DNA loading in gold nanoparticles (AuNPs) and biotin multi-functionalized bio bar codes, streptavidin-HRP was brought to the electrode through the specific interaction with biotin to catalyze the chemical oxidation of hydroquinone by H(2)O(2) to form benzoquinone. The electrochemical reduction signal of benzoquinone was utilized to monitor the miRNA-21 hybridization event. The effect of experimental variables on the amperometric response was investigated and optimized. Based on the specific confirmation of probe and signal amplification, the biosensor showed excellent selectivity and high sensitivity with low detection limit of 0.06 pM. Successful attempts are made in miRNA-21 expression analysis of human hepatocarcinoma BEL-7402 cells and normal human hepatic L02 cells.  相似文献   

7.
A novel electrogenerated chemiluminescence (ECL) biosensor for highly sensitive and selective detection of mercury ion was developed on the basis of mercury-specific oligonucleotide (MSO) served as a molecular recognition element and the ruthenium(II) complex (Ru1) as an ECL emitting species. The biosensor was fabricated on a glassy carbon electrode coated with a thin layer of single wall carbon nanotubes, where the ECL probe, NH(2)-(CH(2))(6)-oligo(ethylene oxide)(6)-MSO?Dend-Ru1, was covalently attached. The Dend-Ru1 pendant was prepared by covalent coupling Ru1 with the 4th generation polyamidoamine dendrimer (Dend), in which each dendrimer contained 35 Ru1 units so that a large amplification of ECL signal was obtained. Upon binding of Hg(2+) to thymine (T) bases of the MSO, the T-Hg-T structure was formed, and the MSO changed from its linear shape to a "hairpin" configuration. Consequently, the Dend-Ru1 approached the electrode surface resulting in the increase of anodic ECL signal in the presence of the ECL coreactant tri-n-propylamine. The reported biosensor showed a high reproducibility and possessed long-term storage stability (92.3% initial ECL recovery over 30 day's storage). An extremely low detection limit of 2.4 pM and a large dynamic range of 7.0 pM to 50 nM Hg(2+) were obtained. An apparent binding constant of 1.6 × 10(9)M(-1) between Hg(2+) and the MSO was estimated using an ECL based extended Langmuir isotherm approach involving multilayer adsorption. Determination of Hg(2+) contents in real water samples was conducted and the data were consistent with the results from cold vapor atomic fluorescence spectroscopy.  相似文献   

8.
Zhang J  Chen P  Wu X  Chen J  Xu L  Chen G  Fu F 《Biosensors & bioelectronics》2011,26(5):2645-2650
A novel signal-on junction-probe electrogenerated chemiluminescence (ECL) aptamer biosensor has been developed for the detection of ultratrace thrombin based on a structure-switching ECL-quenching mechanism. The ECL aptamer biosensor comprises two main parts: an ECL substrate and an ECL intensity switch. The ECL substrate was made by modifying the complex of Au nanoparticle and ruthenium (II) tris-bipyridine (Ru(bpy)(3)(2+)-AuNPs) on the surface of gold electrode (GE), and the ECL intensity switch contains three probes designed according to the "junction-probe" strategy. The first probe is capture probe (Cp) which was functionalized with a thiol group at one end and covalently attached to Ru(bpy)(3)(2+)-AuNPs modified GE through S-Au bonding. The second probe is aptamer probe (Ap), which containing 15-base anti-thrombin DNA aptamer. The third one is ferrocene-labeled probe (Fp), which was functionalized with ferrocene tag at one end. We demonstrated that, in the absence of thrombin, Cp, Ap and Fp will hybridize to form a ternary "Y" junction structure and resulted in a quenching of ECL of Ru(bpy)(3)(2+). Whereas, in the presence of thrombin, the Ap prefers to form the G-quadruplex aptamer-thrombin complex and lead to an obvious recovery of ECL of Ru(bpy)(3)(2+), which provided a sensing platform for the detection of thrombin. Using this reusable sensing platform, a simple, rapid and selective signal-on ECL aptamer biosensor for the detection of thrombin with a detection limit of 8.0×10(-15) M has been developed. The success in the present biosensor served as a significant step towards the development of monitoring ultratrace thrombin in clinical detection.  相似文献   

9.
A novel label free electrochemiluminescence (ECL) immunosensor based on the ECL of peroxydisulfate solution for detection of α-1-fetoprotein (AFP) has been developed. For this proposed immunosensor, L-cysteine was firstly electrodeposited on the gold electrode surface, which promoted the electron transfer and largely enhanced the ECL of peroxydisulfate solution. Subsequently, gold nanoparticles (nano-Au) were assembled onto the L-cysteine film modified electrode to improve the absorption capacity of antibody and further amplify the ECL signal. Then, antibody was immobilized onto the electrode through nano-Au. At last bovine serum albumin (BSA) was employed to block the nonspecific binding sites. As a result, a novel ECL immunosensor was firstly obtained by applying the ECL of peroxydisulfate solution without conventional luminescent reagents. The AFP was determined in the range of 0.01-100 ng mL(-1), with a low detection limit of 3.3 pg mL(-1) (S/N=3). The proposed ECL immunosensor provides a rapid, simple, and sensitive immunoassay protocol for protein detection, which might hold a promise for clinical application. Moreover, this work would open up a new field in the application of peroxydisulfate solution ECL for highly sensitive bioassays.  相似文献   

10.
Nucleic acid sequence-based amplification with electrochemiluminescent detection (NASBA/ECL) is an isothermal technique allowing rapid amplification and detection of specific regions of nucleic acid from a diverse range of sources. It is especially suitable for amplifying RNA. A NASBA/ECL technique has been developed allowing the detection of RNA from avian influenza virus subtype H7 derived from allantoic fluid harvested from inoculated chick embryos and from cell cultures. Degenerate amplification primers and amplicon capture probes were designed enabling the detection of low and highly pathogenic avian influenza of the H7 subtype from the Eurasian and North American lineages and the Australian sub-lineage. The NASBA/ECL technique is specific for subtype H7 and does not cross-react with other influenza subtypes or with viruses containing haemagglutinin-like genes. The assay is 10- to 100-fold more sensitive than a commercially available antigen capture immunoassay system. The NASBA/ECL assay could be used in high throughput poultry screening programmes.  相似文献   

11.
The mechanisms of colorimetric assays based on aggregation of gold nanoparticles (GNPs) have been separated into two categories, crosslinking, and noncrosslinking aggregation. The noncrosslinking aggregation has recently been emerging as a simple and rapid mechanism and has been applied to enzymatic activity assays and DNA detection. We report here the detailed study of an enzymatic activity assay for protein kinases based on noncrosslinking aggregation. The principle of the assay is to detect kinase activity by utilizing the difference of coagulating ability of a cationic substrate peptide and its phosphorylated form toward GNPs with anionic surface charge. The critical coagulation concentrations (CCCs) of the peptides were about 10(3) times lower than those of the metal cations with the same cationic charges. The multivalent coordination bonds of the functional groups of the peptides with the GNP surface will strongly support the adsorption of the peptide on the GNP surface. The effect of the GNP size (10, 20, 40, 60 nm) on the dynamic range of OD before and after aggregation was studied. The dynamic range became a maximum for 20 nm GNP among those studied. The difference of CCC between the phosphorylated and nonphosphorylated peptides was governed by (1) the ratio between the peptide concentration and the surface area concentration of GNP and (2) the net charge of the peptides. When the assay system was applied to the activity assessment of protein kinase A, the dynamic range of OD was largest for 20 nm GNPs. However, when the peptide concentration was lowered, the largest 60 nm GNP was advantageous because of its smaller specific surface area.  相似文献   

12.
Several recent studies have shown that Ca2+/calmodulin-dependent protein kinase I (CaMKI) is phosphorylated and activated by a protein kinase (CaMKK) that is itself subject to regulation by Ca2+/calmodulin. In the present study, we demonstrate that this enzyme cascade is regulated by cAMP-mediated activation of cAMP-dependent protein kinase (PKA). In vitro, CaMKK is phosphorylated by PKA and this is associated with inhibition of enzyme activity. The major site of phosphorylation is threonine 108, although additional sites are phosphorylated with lower efficiency. In vitro, CaMKK is also phosphorylated by CaMKI at the same sites as PKA, suggesting that this regulatory phosphorylation might play a role as a negative-feedback mechanism. In intact PC12 cells, activation of PKA with forskolin resulted in a rapid inhibition of both CaMKK and CaMKI activity. In hippocampal slices CaMKK was phosphorylated under basal conditions, and activation of PKA led to an increase in phosphorylation. Two-dimensional phosphopeptide mapping indicated that activation of PKA led to increased phosphorylation of multiple sites including threonine 108. These results indicate that in vitro and in intact cells the CaMKK/CaMKI cascade is subject to inhibition by PKA-mediated phosphorylation of CaMKK. The phosphorylation and inhibition of CaMKK by PKA is likely to be involved in modulating the balance between cAMP- and Ca2+-dependent signal transduction pathways.  相似文献   

13.
A novel cholesterol biosensor was prepared based on gold nanoparticles-catalyzed luminol electrogenerated chemiluminescence (ECL). Firstly, l-cysteine-reduced graphene oxide composites were modified on the surface of a glassy carbon electrode. Then, gold nanoparticles (AuNPs) were self-assembled on it. Subsequently, cholesterol oxidase (ChOx) was adsorbed on the surface of AuNPs to construct a cholesterol biosensor. The stepwise fabrication processes were characterized with cyclic voltammetry and atomic force microscopy. The ECL behaviors of the biosensor were also investigated. It was found that AuNPs not only provided larger surface area for higher ChOx loading but also formed the nano-structured interface on the electrode surface to improve the analytical performance of the ECL biosensor for cholesterol. Besides, based on the efficient catalytic ability of AuNPs to luminol ECL, the response of the biosensor to cholesterol was linear range from 3.3 μM to 1.0 mM with a detection limit of 1.1 μM (S/N=3). In addition, the prepared ECL biosensor exhibited satisfying reproducibility, stability and selectivity. Taking into account the advantages of ECL, we confidently expect that ECL would have potential applications in biotechnology and clinical diagnosis.  相似文献   

14.
Miao P  Ning L  Li X  Li P  Li G 《Bioconjugate chemistry》2012,23(1):141-145
We herein report a novel electrochemical method in this paper to monitor protein phosphorylation and to assay protein kinase activity based on Zr(4+) mediated signal transition and rolling circle amplification (RCA). First, substrate peptide immobilized on a gold electrode can be phosphorylated by protein kinase A. Then, Zr(4+) links phosphorylated peptide and DNA primer probe by interacting with the phosphate groups. After the introduction of the padlock probe and phi29 DNA polymerase, RCA is achieved on the surface of the electrode. As the RCA product, a very long DNA strand, may absorb a large number of electrochemical speices, [Ru(NH(3))(6)](3+), via the electrostatic interaction, localizing them onto the electrode surface, initiated by protein kinase A, a sensitive electrochemical method to assay the enzyme activity is proposed. The detection limit of the method is as low as 0.5 unit/mL, which might promise this method as a good candidate for monitoring phosphorylation in the future.  相似文献   

15.
Phosphofructokinase (PFK) from sheep heart was shown to be phosphorylated by Ca2+/calmodulin protein kinase (CaM-kinase) as well as by cyclic AMP-dependent protein kinase (PKA). HPLC analysis of phosphorylated PFK indicated that phosphorylation by CaM-kinase occurs at least at two sites that are distinct from those recognized by PKA. Phosphorylation by either CaM-kinase of PKA resulted in an increase in sensitivity to ATP inhibition and a small but consistent decrease in Ki for ATP. Phosphorylation by either protein kinase caused a slight increase in the Km of PFK for fructose-6-P. Protein kinase C failed to phosphorylate PFK. Combinations of PKA, CaM-kinase and protein kinase C did not alter the stoichiometry of phosphorylation and did not change the effect on enzyme activity.  相似文献   

16.
In this paper, a novel label-free electrochemical strategy has been developed for assay of casein kinase II (CK2) activity and inhibition using TiO(2)/MWNTs nanocomposites. This detection system takes advantage of specific binding of the phosphate groups with TiO(2) nanoparticles and fast electron transfer rate of MWNTs. In this strategy, the synthesized TiO(2)/MWNTs nanocomposite was firstly deposited on the surface of a glassy carbon electrode (GCE). The presence of MWNTs not only increased the surface area of the electrode but also promoted electron-transfer reaction. In the presence of CK2, the kinase reaction resulted in the phosphorylation of peptide substrates. The phosphorylated peptides were subsequently captured to the surface of GCE modified with TiO(2)/MWNTs nanocomposite through specific binding of the phosphate groups with TiO(2) nanoparticles. Then the access of redox probe [Fe(CN)(6)](3-/4-) to electrode surface was blocked. As a result, the decrease peak currents were related to the concentrations of the CK2, providing a sensing mechanism for monitoring peptides phosphorylation. The electrochemical strategy can be employed to assay CK2 activity with a low detection limit of 0.07 U/mL. The linear range of the assay for CK2 was 0-0.5 U/mL. Furthermore, the interferences experiments of PKA and inhibition of CK2 have been also studied by using this strategy.  相似文献   

17.
The actions of parathyroid hormone (PTH) on the renal cortex are thought to be mediated primarily by cAMP-dependent protein kinase (PKA) with some suggestion of a role for protein kinase C (PKC). However, present methods for assaying PKA and PKC in subcellular fractions are insensitive and require large amounts of protein. Recently, a sensitive method for measuring the activity of protein kinases has been reported. This method uses synthetic peptides as substrates and a tandem chromatographic procedure for isolating the phosphorylated peptides. We have adapted this method to study the effect of PTH on PKA and PKC activity using thin slices of rat renal cortex. PTH (250 nM) stimulated cytosolic PKA activity four- to fivefold within 30 s, and PKA activity was sustained for at least 5 min. PTH also rapidly stimulated PKC activity in the membrane fraction and decreased PKC activity in the cytosol. These changes were maximal at 30 s, but unlike changes in PKA, they declined rapidly thereafter. PTH significantly activated PKC only at concentrations of 10 nM or greater. This study demonstrates that PTH does activate PKC in renal tissue, although the duration of activation is much less than for PKA. It also demonstrates that a combination of synthetic peptides with tandem chromatography can be used as a sensitive assay procedure for protein kinase activity in biological samples.  相似文献   

18.
A microplate-based electrophoretic assay has been developed for the serine/threonine kinase protein kinase A (PKA). The ElectroCapture PKA assay developed uses a positively charged, lissamine-rhodamine-labeled kemptide peptide substrate for the kinase reaction and Nanogen's ElectroCapture HTS Workstation and 384-well laminated membrane plates to electrophoretically separate the negatively charged phosphorylated peptide product from the kinase reaction mix. After the electrophoretic separation, the amount of rhodamine-labeled phosphopeptide product was quantified using a Tecan Ultra384 fluorescence reader. The ElectroCapture PKA assay was validated with both known PKA inhibitors and library compounds. The pK(iapp) results obtained in the ElectroCapture PKA assay were comparable to those generated with current radioactive filter-binding assay and antibody-based competitive fluorescence polarization PKA assay formats.  相似文献   

19.
Epithelial ovarian cancer (EOC) is the deadliest of the gynecological malignancies, due in part to its clinically occult metastasis. Therefore, understanding the mechanisms governing EOC dissemination and invasion may provide new targets for antimetastatic therapies or new methods for detection of metastatic disease. The cAMP-dependent protein kinase (PKA) is often dysregulated in EOC. Furthermore, PKA activity and subcellular localization by A-kinase anchoring proteins (AKAPs) are important regulators of cytoskeletal dynamics and cell migration. Thus, we sought to study the role of PKA and AKAP function in both EOC cell migration and invasion. Using the plasma membrane-directed PKA biosensor, pmAKAR3, and an improved migration/invasion assay, we show that PKA is activated at the leading edge of migrating SKOV-3 EOC cells, and that inhibition of PKA activity blocks SKOV-3 cell migration. Furthermore, we show that while the PKA activity within the leading edge of these cells is mediated by anchoring of type-II regulatory PKA subunits (RII), inhibition of anchoring of either RI or RII PKA subunits blocks cell migration. Importantly, we also show--for the first time--that PKA activity is up-regulated at the leading edge of SKOV-3 cells during invasion of a three-dimensional extracellular matrix and, as seen for migration, inhibition of either PKA activity or AKAP-mediated PKA anchoring blocks matrix invasion. These data are the first to demonstrate that the invasion of extracellular matrix by cancer cells elicits activation of PKA within the invasive leading edge and that both PKA activity and anchoring are required for matrix invasion. These observations suggest a role for PKA and AKAP activity in EOC metastasis.  相似文献   

20.
A novel nanoparticle-based electrochemiluminescence (ECL) immunosensor was designed for highly sensitive and selective detection of human cardiac troponin I (cTnI), an important Acute Myocardial Infarction (AMI)-related biomarker, by using N-(aminobutyl)-N-(ethylisoluminol)-functionalized gold nanoparticles (ABEI-AuNPs) as labels. ABEI-AuNPs were successfully synthesized via a simple seed growth method. A great number of luminescence molecules ABEI as stabilizers were coated on the surface of the AuNPs, which exhibited better ECL activities than previously reported luminol functionalized gold nanoparticles. ABEI-AuNPs were used as new ECL labels to build bio-probes by conjugation with secondary antibodies, which showed good ECL activity, immunological activity, and stability. Another kind of AuNPs functionalized with streptavidin was modified on the electrode surface for biotinylated antibodies capture through the specific interaction of biotin/streptavidin and enhancing the electrical connectivity. By combining with the novel ECL labels and amplification of AuNPs and biotin-streptavidin system, a high sensitive sandwich-type electrochemiluminescence immunoassay was developed for detecting human cTnI with a low detection limit of 2 pg/mL. The immunosensor showed good precision, acceptable stability and reproducibility and could be used for the detection of cTnI in real samples, which was of great potential application in clinical analysis. Importantly, the sensitive detection would have far more diagnostic value than would absolute measurements during the early stage of AMI.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号