首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A selective high-performance liquid chromatographic (HPLC) assay for a sigma receptor antagonist, DuP 734 (I), in rat plasma has been developed. Compound I and internal standard, XC031 (I.S.), were first extracted from plasma into an ethyl acetate—toluene mixture (3:7, v/v) and then back-extracted into freshly prepared phosphoric acid (0.03 M). Separation of I and I.S. with no interference from endogenous substances was achieved on a reversed-phase octyl column and detection was by UV at 229 nm. The mobile phase consisted of acetonitrile—glacial acetic acid—triethylamine—0.05 M ammonium acetate (670:4:2:2000, v/v). Using 0.5 ml of rat plasma for extraction, the limit of quantitation was 43 ng/ml and the assay was linear from 43 to 8536 ng/ml. The intra- and inter-day coefficients of variation ranged from 0.7 to 3.0%, and from 1.4 to 14.5%, respectively, over the entire concentration range. The accuracy was within 16.1% of the spiked concentrations. I was stable in frozen plasma at −20°C for at least 68 days.  相似文献   

2.
A highly efficient and reproducible two-step liquid—liquid ion-pair extraction technique for the isolation of morphine from biological samples is described. A rapid normal phase high-performance liquid chromatographic procedure coupled with amperometric electrochemical detection has also been developed for subsequent quantification of morphine. Extraction involves the disruption of brain tissue or plasma in methanol, centrifugation, evaporation and reconstitution in ethyl acetate containing 10 mM di-(2-ethylhexyl) phosphoric acid, a liquid cation-exchanger, and back-extraction into 170 mM orthophosphoric acid. An acidic eluent consisting of acetonitrile—76 mM orthophosphoric acid—ammonia buffer (pH 3.0) (15:85, v/v) in combination with a strong cation-exchange column allows complete separation of morphine and the internal standard, nalbuphine. The limit of detection for morphine is 1.3 ng on-column.  相似文献   

3.
An improved, rapid and specific high-performance liquid chromatographic assay was developed for the determination of famotidine in human plasma and urine. Plasma samples were alkalinized and the analyte and internal standard (cimetidine) extracted with water-saturated ethyl acetate. The extracts were reconstituted in mobile phase, and injected onto a C18 reversed-phase column; UV detection was set at 267 nm. Urine samples were diluted with nine volumes of a mobile phase-internal standard mixture prior to injection. The lower limits of quantification in plasma and urine were 75 ng/ml and 1.0 μg/ml, respectively; intra- and inter-day coefficients of variation were ≤10.5%. This method is currently being used to support renal function studies assessing the use of intravenously administered famotidine to characterize cationic tubular secretion in man.  相似文献   

4.
A simple high-performance liquid chromatographic (HPLC) method was developed for the determination of losartan and its E-3174 metabolite in human plasma, urine and dialysate. For plasma, a gradient mobile phase consisting of 25 mM potassium phosphate and acetonitrile pH 2.2 was used with a phenyl analytical column and fluorescence detection. For urine and dialysate, an isocratic mobile phase consisting of 25 mM potassium phosphate and acetonitrile (60:40, v/v) pH 2.2 was used. The method demonstrated linearity from 10 to 1000 ng/ml with a detection limit of 1 ng/ml for losartan and E-3174 using 10 μl of prepared plasma, urine or dialysate. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of losartan in patients with kidney failure undergoing continuous ambulatory peritoneal dialysis (CAPD).  相似文献   

5.
A sensitive, quantitative reversed-phase high-performance liquid chromatographic method has been established for the simultaneous determination of butorphanol, a synthetic opioid, and its metabolites, hydroxybutorphanol and norbutorphanol, in human urine samples. The method involved extraction of butorphanol, hydroxybutorphanol, and norbutorphanol from urine (1.0 ml), buffered with 0.1 ml of 1.0 M ammonium acetate (pH 6.0), onto 1-ml Cyano Bond Elut columns. The eluent was evaporated under nitrogen and low heat, and reconstituted with the HPLC mobile phase, acetonitrile—methanol—water (20:10:70, v/v/v), containing 10 mM ammonium acetate and 10 mM TMAH (pH 5.0). The samples were chromatographed on a reversed-phase octyl 5-μm column. The analysis was accomplished by detection of the fluorescence of the three analytes, at excitation and emission wavelengths of 200 nm and 325 nm, respectively. The retention times for hydroxybutorphanol, norbutorphanol, the internal standard, and butorphanol were 5.5, 9.0, 13.0, and 23.4 min respectively. The validated quantitation range of the method was 1–100 ng/ml for butorphanol and hydroxybutorphanol, and 2–200 ng/ml for norbutorphanol in urine. The observed recoveries for butorphanol, hydroxybutorphanol, and norbutorphanol were 93%, 72%, and 50%, respectively. Standard curve correlation coefficients of 0.995 or greater were obtained during validation experiments and analysis of study samples. The method was applied on study samples from a clinical study of butorphanol, providing a pharmacokinetic profiling of butorphanol.  相似文献   

6.
An isocratic high-performance liquid chromatographic method has been developed to determine ciprofloxacin levels in chinchilla plasma and middle ear fluid. Ciprofloxacin and the internal standard, difloxacin, were separated on a Keystone ODS column (100 × 2.1 mm I.D., 5 μm Hypersil) using a mobile phase of 30 mM phosphate buffer (pH 3), 20 mM triethylamine, 20 mM sodium dodecyl sulphate—acetonitrile (60:40, v/v). The retention times were 3.0 min for ciprofloxacin and 5.2 min for difloxacin. This fast, efficient protein precipitation procedure together with fluorescence detection allows a quantification limit of 25 ng/ml with a 50 μl sample size. The detection limit is 5 ng/ml with a signal-to-noise ratio of 5:1. Recoveries (mean ± S.D., n = 5) at 100 ng/ml in plasma and middle ear fluid were 89.4 ± 1.2% and 91.4 ± 1.6%, respectively. The method was evaluated with biological samples taken from chinchillas with middle ear infections after administering ciprofloxacin.  相似文献   

7.
A double column-switching high-performance liquid chromatographic (HPLC) method for the determination of concentrations for TAK-603 (T) and its metabolites, T-72258 (M-I) and T-72294 (M-III), in human serum was developed. The analytes were extracted with ethyl acetate from human serum samples treated with triethylamine and injected into the HPLC system. Separation of the analytes was performed on the HPLC system with double column-switching technique. The mobile phases A and B for the first column and the mobile phase C for the second column used were a mixture of methanol–10 mM aqueous ammonium acetate solution (1:1, v/v), methanol and a mixture of methanol–10 mM aqueous ammonium acetate solution (11:9, v/v), respectively. The eluate was monitored with a UV detector at a wavelength of 253 nm. The work-up procedure was reproducible and more than 90% of the analytes could be recovered from human serum. The lower limits of quantitation were all 1 ng/ml for the analytes when 0.5 ml of human serum was used. Standard curves were linear with a correlation coefficient (R) of more than 0.999 in the range of 1–500 ng/ml for T, M-I and M-III in human serum. The intra- and inter-day precision of the method for the various analytes were below 4.8%. The accuracy was good with the deviations between spiked and calculated concentrations of the analytes being within 11.0%. The method was successfully applied to analyze serum samples after an oral administration of T to healthy male volunteers.  相似文献   

8.
Pyrazoloacridine (PZA) is a 9-methoxy substituted acridine with a reducible nitro group. PZA has shown selective solid tumor cytotoxicity with activity against hypoxic cells, non-cycling cells and cells expressing the multidrug resistant phenotype. A high-performance liquid chromatographic (HPLC) assay was developed and validated for the determination of PZA in human plasma to support phase II clinical trials. PZA and ethyl orange, the internal standard, were isolated from human plasma by precipitating plasma proteins with methanol, and centrifuging to pellet the proteins. The resulting supernatant was injected onto a cyanopropyl HPLC column eluted isocratically with a mobile phase consisting of 125 mM ammonium acetate buffer pH 4.75-acetonitrile (76:24, v/v). A single wavelength at 460 nm was used for detection. Relative standard deviations for the assay ranged from 5.0% to 12.2% for four different drug concentrations and the limit of quantitation was 100 ng/ml. During the validation short term stability of the drug in plasma and stability of PZA on repeated freezing and thawing of plasma was evaluated. Overall recovery of PZA was 88%. This simple assay was found suitable for studying the clinical pharmacokinetics of PZA.  相似文献   

9.
A reversed-phase high-performance liquid chromatographic assay (HPLC) was utilized for monitoring xanomeline (LY246708/NNC 11–0232) and a metabolite, desmethylxanomeline, in human plasma. Xanomeline, desmethylxanomeline and internal standard were extracted from plasma with hexane at basic pH. The organic solvent extract was evaporated to dryness with nitrogen and the dried residue was reconstituted with 0.2 M HCl-methanol (50:50, v/v). A Zorbax CN 150 × 4.6 mm I.D., 5-μm column and mobile phase consisting of 0.5% (5 ml/l) triethylamine (TEA) adjusted to pH 3.0 with concentrated orthophosphoric acid-tetrahydrofuran (THF) (70:30, v/v) produced consistent resolution of analytes from endogenous co-extracted plasma components. Column effluent was monitored at 296 nm/0.008 a.u.f.s. and the assay limit of quantification was 1.5 ng/ml. A linear response of 1.5 to 20 ng/ml was sufficient to monitor plasma drug/metabolite concentrations during clinical trials. HPLC assay validation as well as routine assay quality control (QC) samples indicated assay precision/accuracy was better than ±15%.  相似文献   

10.
An improved high-performance liquid chromatographic (HPLC) method utilizing solid-phase extraction (SPE) and midbore chromatography was developed for the determination of ranitidine in human plasma. A mobile phase of 20 mM K2HPO4-acetonitrile-triethylamine (87.9:12.0:0.1, v/v) pH 6.0 was used with a phenyl analytical column and ultraviolet detection (UV). The method demonstrated linearity from 25 to 1000 ng/ml in 500 μl of plasma with a detection limit of 10 ng/ml. The method was utilized in a pharmacokinetic study evaluating the effects of pancreatico-biliary secretions on ranitidine absorption.  相似文献   

11.
A simple and sensitive high-performance liquid chromatographic (HPLC) method with UV absorbance detection is described for the quantitation of risperidone and its major metabolite 9-hydroxyrisperidone in human plasma, using clozapine as internal standard. After sample alkalinization with 1 ml of NaOH (2 M) the test compounds were extracted from plasma using diisopropyl ether–isoamylalcohol (99:1, v/v). The organic phase was back-extracted with 150 μl potassium phosphate (0.1 M, pH 2.2) and 60 μl of the acid solution was injected into a C18 BDS Hypersil analytical column (3 μm, 100×4.6 mm I.D.). The mobile phase consisted of phosphate buffer (0.05 M, pH 3.7 with 25% H3PO4)–acetonitrile (70:30, v/v), and was delivered at a flow-rate of 1.0 ml/min. The peaks were detected using a UV detector set at 278 nm and the total time for a chromatographic separation was about 4 min. The method was validated for the concentration range 5–100 ng/ml. Mean recoveries were 98.0% for risperidone and 83.5% for 9-hydroxyrisperidone. Intra- and inter-day relative standard deviations were less than 11% for both compounds, while accuracy, expressed as percent error, ranged from 1.6 to 25%. The limit of quantitation was 2 ng/ml for both analytes. The method shows good specificity with respect to commonly prescribed psychotropic drugs, and it has successfully been applied for pharmacokinetic studies and therapeutic drug monitoring.  相似文献   

12.
A method for the determination of unconjugated phentolamine at concentrations down to 6 ng/ml in human plasma, and of free and total (free plus conjugated) phentolamine down to 25 ng/ml in urine is described. After addition of 2-[N-(p-chlorophenyl)-N-(m-hydroxyphenyl)-aminomethyl]-2-imidazoline as internal standard, both compounds are extracted into benzene—ethyl acetate (1:1, v/v) at pH 10, transferred into an acidic aqueous solution and back-extracted at pH 10 into benzene—ethyl acetate. They are then derivatized with N-heptafluorobutyrylimidazole. The derivatives are determined by gas chromatography using a 63Ni electron-capture detector. In urine, total (free plus conjugated) phentolamine is determined after enzymatic hydrolysis. The technique was applied for the study of the plasma concentrations and urinary elimination after oral administration to man.  相似文献   

13.
A sensitive and specific high-performance liquid chromatographic method with fluorescence detection (excitation wavelength: 280 nm; emission wavelength: 360 nm) was developed and validated for the determination of vinorelbine in plasma and blood samples. The sample pretreatment procedure involved two liquid–liquid extraction steps. Vinblastine served as the internal standard. The system uses a Spherisorb cyano analytical column (250×4.6 mm I.D.) packed with 5 μm diameter particles as the stationary phase and a mobile phase of acetonitrile–80 mM ammonium acetate (50:50, v/v) adjusted to pH 2.5 with hydrochloric acid. The assay showed linearity from 1 to 100 ng/ml in plasma and from 2.5 to 100 ng/ml in blood. The limits of quantitation were 1 ng/ml and 2.5 ng/ml, respectively. Precision expressed as RSD was in the range 3.9 to 20% (limit of quantitation). Accuracy ranged from 92 to 120%. Extraction recoveries from plasma and blood averaged 101 and 75%, respectively. This method was used to follow the time course of the concentration of vinorelbine in human plasma and blood samples after a 10-min infusion period of 20 mg/m2 of this drug in patients with metastatic cancer.  相似文献   

14.
A simple, specific and sensitive high-performance liquid chromatographic (HPLC) method was developed for the determination of rifabutin in human plasma. Rifabutin and sulindac (internal standard) are extracted from human plasma using a C8 Bond Elut extraction column. Methanol (1 ml) is used to elute the compounds. The methanol is dried down under nitrogen and reconstituted in 250 μl of mobile phase. Separation is achieved by HPLC on a Zorbax Rx C8 column with a mobile phase composed of 0.05 M potassium dihydrogen phosphate and 0.05 M sodium acetate at pH 4.0-acetonitrile (53:47, v/v). Detection is by ultraviolet absorbance at 275 nm. The retention times of rifabutin and internal standard were approximately 10.8 and 6.9 min, respectively. The assay is linear over the concentration range of 5–600 ng/ml. The quantitation limit was 5 ng/ml. Both intra-day and inter-day accuracy and precision data showed good reproducibility.  相似文献   

15.
A reversed-phase high-performance liquid chromatographic method for the determination of benflumetol in human plasma is described. Benflumetol in plasma samples was extracted with a glacial acetic acid-ethyl acetate (1:100, v/v) mixture at pH 4.0. Chromatography was performed on a Spherisorb C18 column using a methanol-water-glacial acetic acid-diethyl amine (93:6:1:0.03, v/v) mixture as the mobile phase and UV-VIS detection at 335 nm. The identity and purity of the benflumetol peak were carefully examined, and the internal standard method was applied for its quantitation. The absolute recovery of benflumetol in spiked plasma samples was 92.91% over the concentration range 5–4000 ng/ml. The recovery of internal standard “8212” at a concentration of 300 ng/ml in spiked plasma was 84.85%. The detection limit of benflumetol was 11.8 ng/ml. Plasma concentration-time profiles in healthy volunteer adults were measured after a single-dose oral administration of 500 mg of benflumetol. The assay procedures were within the quality control limits.  相似文献   

16.
A high-performance liquid chromatographic method for the determination of the histamine H1-receptor antagonist cetirizine in human urine was developed. Cetirizine and the internal standard are extracted from acidified (pH 5) urine (0.5 ml) into chloroform and the organic layer is evaporated to dryness. The residue is chromatographed on a Spherisorb 5ODS-2 column using Pic A (5 mM aqueous tetrabutylammonium phosphate)—methanol—tetrahydrofuran (33:65:2, v/v) as the mobile phase with ultraviolet detection (230 nm). The calibration graph is linear from 0.1 to 10 μg/ml and using 0.5 ml of urine the detection limit is 20 ng/ml. The within-run relative standard deviation is <6% and the accuracy is within 10% of the theoretical value at concentrations between 0.1 and 10 μg/ml in urine. There is a good correlation (r = 0.99606) with a previously described capillary gas chromatographic assay.  相似文献   

17.
We developed and characterized a high-performance liquid chromatography (HPLC) assay for the determination of saquinavir, an HIV protease inhibitor, in human plasma samples. Extraction of plasma samples with diethyl ether resulted in quantitative recovery of both saquinavir and its stereoisomer Ro 31-8533 which was used as an internal standard. The assay was performed isocratically using 5 mM H2SO4 (pH 3.5) and acetonitrile (75.5:24.5, v/v) containing 10 mM tetrabutylammonium hydrogen sulfate (TBA) as a mobile phase, a Nucleosil 3C8 column kept at 45°C and UV detection at 240 nm. Using this method, saquinavir and Ro 31-8533 can be separated from endogenous substances, and in the concentration range of 5–110 ng/ml the relative standard deviations for the determination of saquinavir were below 5%. The detection limit of saquinavir in human plasma was 1 ng/ml. The usefulness of the method was demonstrated by quantification of saquinavir in plasma of human subjects treated with 600 mg of saquinavir per os or 12 mg intravenously.  相似文献   

18.
A simple high-performance liquid chromatographic procedure was developed for the determination of ranitidine in human plasma. The method entailed direct injection of the plasma samples after deproteination using perchloric acid. The chromatographic separation was accomplished with an isocratic elution using mobile phase consisting of 21 mM disodium hydrogen phosphate–triethylamine-acetonitrile (1000:60:150, v/v), pH 3.5. Analyses were run at a flow-rate of 1.3 ml/min using a μbondapak C18 column and ultraviolet detection at a wavelength of 320 nm. The method was specific and sensitive, with a quantification limit of approximately 20 ng/ml and a detection limit of 5 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery was about 96%, while the within- and between-day coefficient of variation and percent error values of the assay method were all less than 8%. The linearity was assessed in the range of 20–1000 ng/ml plasma, with a correlation coefficient of greater than 0.999. This method has been used to analyze several hundred human plasma samples for bioavailability studies.  相似文献   

19.
A high-performance liquid chromatographic method is described for the determination of free captopril in human plasma. (NAC) was used as an internal standard. Plasma samples were immediately derivatized with N-(1-pyrenyl)maleimide (NPM) and stabilized with 11 M HCl. The drug of interest was isolated using a liquid-liquid extraction with ethyl acetate and separation was obtained using a reversed-phase column under isocratic conditions with fluorescence detection. The sample volume was 150 μl plasma. The intra- and inter-day accuracy and precision, determined as relative error and coefficient of variation respectively, were lessthan 10%. The lower limit of quantitation, based on standards with acceptable coefficients of variation, was 25 ng/ml. No endogenous compounds were found to interfere. The linearity was assessed in the range of 25–600 ng/ml. This method has been demonstrated to be suitable for pharmacokinetic studies in humans.  相似文献   

20.
A sensitive high-performance liquid chromatographic method for a routine assay of nadolol in serum is described. Serum samples spiked with atenolol (internal standard) were extracted with diethyl ether. After centrifugation, the organic layer was evaporated to dryness. The residue was redissolved in the mobile phase and injected onto an octadecyl silica column (150 mm × 4.6 mm I.D.). The mobile phase was 0.05 M ammonium acetate (pH 4.5)—acetonitrile (85:15, v/v). Fluorometric detection (excitation 230 nm, emission 300 nm) was used. The minimum detectable level of nadolol in serum was 1 ng/ml.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号