首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Effects of the overstressing induced by the harvest of grafts from the patellar tendon on the mechanical properties and morphometry of remaining tendon were studied using a rabbit model. The width of the patellar tendon was reduced by one-fourth or one-half equally removing the medial and lateral portions; by this surgery, the cross-sectional area was decreased by 25 or 50 percent from the original area. After all the rabbits were allowed unrestricted activities in cages for 3 to 12 weeks, their patellar tendons were harvested for mechanical and histological studies. The one-fourth removal induced no significant changes in the mechanical properties, but significantly increased the cross-sectional area. In the case of one-half removal, tensile strength and tangent modulus did not change in some tendons, although the cross-sectional area increased significantly. In the other central half tendons, mechanical strength decreased markedly, while the cross-sectional area increased; hypercellular areas and breakage of collagen bundles were observed in these tendons. These results indicate that the patellar tendon has an ability of functionally adapting to overstressing by changing the cross-sectional area, while keeping the mechanical properties unchanged, if the extent of overstressing is less than 30 percent.  相似文献   

2.
The purpose of the present study is to determine the effect of the stress enhancement and intrinsic fibroblasts on the extracellular matrix of the patellar tendon. Thirty-two female Japanese White rabbits were divided into four groups. In Group 1, the patellar tendon underwent the in situ freeze-thaw treatment to kill intrinsic fibroblasts of the patellar tendon and the patellar tendon underwent the wrapping treatment with nylon membrane filters to inhibit extrinsic cell infiltration. In Group 2, the medial and the lateral portions of the frozen-thawed patellar tendon were resected to enhance the stress, and then the central two-thirds of the patellar tendon underwent the wrapping treatment. In Group 3, the patellar tendon without the freeze/thaw treatment underwent the wrapping treatment. In Group 4, the patellar tendon was narrowed and wrapped in the same manner. All rabbits were killed 6 weeks after surgery. While the elastic modulus and the tensile strength of the patellar tendon in Group 2 were significantly less than those in Group 1, we could not find any significant differences in these parameters between Groups 3 and 4. Histologically, while no fibroblasts were observed in Groups 1 and 2, fibroblasts were found in Groups 3 and 4. This study revealed that stress enhancement decreases the elastic modulus and the tensile strength of the extracellular matrix of the patellar tendon and that intrinsic fibroblasts prevent the detrimental effect of stress enhancement on mechanical properties of the patellar tendon.  相似文献   

3.
Plantar fascia (PF) is a heterogeneous thickness structure across plantar foot. It is important significance to investigate the biomechanical behavior of the medial, middle and lateral PF regions. To investigate the non-uniform macro/micro structures of the different PF regions, the uniaxial tensile test of PF strips were performed to assess the mechanical behavior of PF. A scanning electron microscope (SEM) was used to visualize and measure the micro morphology of PF associated with collagen fibers. A three-dimensional foot finite element (FE) model was developed to quantify the tensile behavior of the internal PF. The elastic modulus of the lateral PF component (1560 MPa) was observed, followed by the medial (701 MPa), the central (1100 MPa) and the lateral (714 MPa) portions in the central component. Elongation of the central portion (0.192) was lower than the medial (0.223) and the lateral (0.227) portions. The corresponding SEM images showed that the fibers of the central portion were more densely packed and thicker compared to the ambilateral portions in the central component. While the FE model prediction also suggested that the greater elastic modulus of the central PF portion had lower strain (0.192) versus the ambilateral portions. Therefore, the lower elongation and greater elastic modulus at the central portion of PF would probably have a high risk of PF injury. The findings showed a relation between the mechanical tension and fibrous morphology of PF. This information would have a better understanding of the PF pathophysiology diseases related to tear and injury of PF.  相似文献   

4.
Growth-related changes in the mechanical properties of collagen fascicles (approximately 300 microm in diameter) were studied using patellar tendons obtained from skeletally immature 1 and 2 months old and matured 6 months old rabbits. Tensile properties were determined using a specially designed micro-tensile tester. In each age group, there were no significant differences in the properties among cross-sectional locations in the tendon. Tangent modulus and tensile strength significantly increased with age; the rates of their increases between 1 and 2 months were higher than those between 2 and 6 months. The tangent modulus and tensile strength were positively correlated with the body weight of animals. However, growth-related changes in the mechanical properties were different between collagen fascicles and bulk patellar tendons, which may be attributable to such non-collagenous components as ground substances and also to mechanical interactions between collagen fascicles.  相似文献   

5.
Previous studies have shown that, in the stress-shielded patellar tendon, the mechanical properties of the tendon were dramatically reduced and TGF-beta was over-expressed in tendon fibroblasts. In the present study, therefore, we tested two supportive hypotheses using 40 rabbits: One was that an application of TGF-beta1 might significantly increase the tensile strength and the tangent modulus of the stress-shielded patellar tendon. The other one was that an administration of anti-TGF-beta1 antibody might significantly reduce the mechanical properties of the stress-shielded patellar tendon. In the results, an application of 4-ng TGF-beta1 significantly increased the tangent modulus of the stress-shielded patellar tendon at 3 weeks (p = 0.019), compared with the sham treatment. Concerning the tensile strength, the 4-ng TGF-beta1 application increased the average value, but a statistical significance was not reached. An application of 50-microg anti-TGF-beta1 antibody significantly reduced the tangent modulus and the tensile strength of the stress-shielded patellar tendon at 3 weeks (p = 0.0068 and p = 0.0355), compared with the sham treatment. Because the stress-shielding treatment used in this study dramatically reduces the tangent modulus and the tensile strength of the patellar tendon, the present study suggested that an administration of TGF-beta1 weakly but significantly inhibited the reduction of the mechanical properties of the stress-shielded patellar tendon, and that inactivation of TGF-beta1 with its antibody significantly enhanced the reduction of the mechanical properties that occurs in the stress-shielded patellar tendon. These results suggested that TGF-beta1 plays an important role in remodeling of the stress-shielded patellar tendon.  相似文献   

6.
The mechanical properties of RTT collagen tendon before and after UV irradiation have been investigated by mechanical testing (Instron). Air-dried tendon were submitted to treatment with UV irradiation (wavelength 254 nm) for different time intervals. The changes in such mechanical properties as breaking strength and percentage elongation have been investigated. The results have shown, that the mechanical properties of the tendon were greatly affected by time of UV irradiation. Ultimate tensile strength and ultimate percentage elongation decreased after UV irradiation of the tendon. Increasing UV irradiation leads to a decrease in Young's modulus of the tendon.  相似文献   

7.
Mechanical properties of collagen fascicles from the rabbit patellar tendon   总被引:1,自引:0,他引:1  
Tensile and viscoelastic properties of collagen fascicles of approximately 300 microns in diameter, which were obtained from rabbit patellar tendons, were studied using a newly designed micro-tensile tester. Their cross-sectional areas were determined with a video dimension analyzer combined with a CCD camera and a low magnification microscope. There were no statistically significant differences in tensile properties among the fascicles obtained from six medial-to-lateral locations of the patellar tendon. Tangent modulus, tensile strength, and strain at failure of the fascicles determined at about 1.5 percent/s strain rate were 216 +/- 68 MPa, 17.2 +/- 4.1 MPa, and 10.9 +/- 1.6 percent (mean +/- S.D.), respectively. These properties were much different from those of bulk patellar tendons; for example, the tensile strength and strain at failure of these fascicles were 42 percent and 179 percent of those of bulk tendons, respectively. Tangent modulus and tensile strength of collagen fascicles determined at 1 percent/s strain rate were 35 percent larger than those at 0.01 percent/s. The strain at failure was independent of strain rate. Relaxation tests showed that the reduction of stress was approximately 25 percent at 300 seconds. These stress relaxation behavior and strain rate effects of collagen fascicles differed greatly from those of bulk tendons. The differences in tensile and viscoelastic properties between fascicles and bulk tendons may be attributable to ground substances, mechanical interaction between fascicles, and the difference of crimp structure of collagen fibrils.  相似文献   

8.
Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials.  相似文献   

9.
We previously found that interleukin (IL)-1beta is over-expressed in the fibroblasts of the stress-shielded patellar tendon using a stress-shielding model [Uchida, H., Tohyama, H., Nagashima, K., Ohba, Y., Matsumoto, H., Toyama, Y., Yasuda, K., 2005. Stress deprivation simultaneously induces over-expression of interleukin-1beta, tumor necrosis factor-alpha, and transforming growth factor-beta in fibroblasts and mechanical deterioration of the tissue in the patellar tendon. Journal of Biomechanics 38(4), 791-798.]. Therefore, IL-1beta may play a role in tendon deterioration in response to stress deprivation. This study was conducted to clarify the effects of local administration of interleukin-1 receptor antagonist (IL-1ra) on the mechanical properties of the stress-shielded patellar tendon as well as the tendon fascicles harvested from it. Twenty-six mature rabbits were equally divided into Groups IL-1ra and PBS after the right patellar tendon underwent the stress-shielding treatment, which completely released the patellar tendon from tension by stretching the flexible wire installed between the patella and the tibial tubercle. In Group IL-1ra, IL-1ra was injected between the patellar tendon and the infra-patellar fat pad. In Group PBS, phosphate-buffered saline was injected in the same manner as IL-1ra. All rabbits were evaluated at 3 weeks after the stress-shielding procedure. The tangent modulus and the tensile strength of the patellar tendons were significantly greater in Group IL-1ra than in Group PBS, while there was no significant difference in the strain at failure between Groups IL-1ra and PBS. Concerning the mechanical properties of the fascicles harvested from the patellar tendon, however, we could not detect any significant differences in the tangent modulus, tensile strength, or strain at failure between Groups IL-1ra and PBS. The present study suggested that IL-1 plays an important role in the deterioration of the mechanical properties of the patellar tendon in response to stress shielding and that IL-1 does not affect the fascicles themselves.  相似文献   

10.
In-vitro tissue culture experiments were performed to study the effects of static stress on the mechanical properties of collagen fascicles obtained from the rabbit patellar tendon. After collagen fascicles having the diameter of approximately 300 microm were cultured for 1 and 2 wk under static stress between 0 and 3 MPa, their mechanical properties and crimp morphology were determined using a micro-tensile tester and a light microscope, respectively. The tensile strength and tangent modulus of the fascicles were significantly decreased by culture under no load compared to control fascicles. A statistically significant correlation, which was described by a quadratic curve, was observed between applied stress and tensile strength. The maximum tensile strength (16.7 MPa) was obtained at the applied stress of 1.2 MPa; the strength was within a range of control values. There was a similar correlation between applied stress and tangent modulus, and the modulus was maintained at control level under 1.3 MPa stress. The stress of 1.2 to 1.3 MPa is equivalent to approximately 50 percent of the peak stress developed in the intact rabbit patellar tendon by running. Strain at failure of cultured collagen fascicles was negatively correlated with applied stress, and that at 1.2 to 1.3 MPa stress was almost the same as the control value. Crimp morphology in the fascicles cultured under about 1.2 MPa stress was similar to that in control fascicles. These results indicate that cultured collagen fascicles change the mechanical properties and structure in response to static tensile stress. In addition, their mechanical properties and structure are maintained at control level if the static stress of 50 percent of in-vivo peak stress is applied.  相似文献   

11.
The biomechanical properties of the medial collateral and anterior cruciate ligaments from 30 New Zealand White rabbits were measured. Because of its complex geometry, the ACL was divided into two portions (medial and lateral) to provide uniform loading. This allowed an examination of the intra-ligamentous properties. A laser micrometer system was used to measure the cross-sectional area for tensile stress and a video dimension analyzer was used to measure the strain. The mechanical properties (stress-strain curves) of the MCL and ACL were different, with the modulus (determined between 4 and 7% strain) in the MCL (1120 +/- 153 MPa) more than twice that of either portion of the ACL (516 +/- 64 and 516 +/- 69 MPa for the medial and lateral portions, respectively). This higher modulus correlated with the more uniform and dense appearance of the collagen fibrils examined with scanning electron microscopy (SEM).  相似文献   

12.
In order to provide insight into the mechanical response of the collagen fascicle structures in tendon, a series of constant strain rate and constant displacement, stress relaxation mechanical tests were performed on sequentially sectioned human patellar tendon specimens (protocol 1) and specimens with both small (approximately 1 mm2) and large (approximately 20 mm2) cross-sectional areas (protocol 2). These data described the stress relaxation and constant strain rate tensile responses as a function of cross-sectional area and water content. The experimental data suggested that small portions of tendon exhibit a higher tensile modulus, a slower rate of relaxation and a lower amount of relaxation in comparison to larger specimens from the same location in the same tendon. The decrease in relaxation response and the increase in tensile modulus with decreasing cross-sectional area was nonlinear. These data suggest that there may be structures other than the subfascicle, such as the epitenon and other connective tissue components, which influence the tensile and stress relaxation responses in tendon.  相似文献   

13.
Active mobilization of repaired flexor tendons requires sufficient suture strength. This study was designed to investigate the suitability of four newly developed and comparatively strong tendon sutures for flexor tendon repair with active digital mobilization. Fifty fresh flexor digitorum profundus tendons were randomly assigned to five groups and repaired using the Tang, cruciate, Robertson, Silfverskiold, and modified Kessler suture methods. The repaired tendons were subjected to mechanical testing in an Instron tensile machine to determine the 2-mm gap formation force, ultimate strength, elastic modulus, and energy to failure of the sutures. The 2-mm gap formation forces of the sutures were 43.0 N for the Tang, 37.4 N for the cruciate, 25.0 N for the Robertson, 32.3 N for the Silfverskiold, and 21.2 N for the modified Kessler methods. The ultimate strength of the sutures was 53.6 N for the Tang, 46.3 N for the cruciate, 41.6 N for the Robertson, 41.0 N for the Silfverskiold, and 24.7 N for the modified Kessler methods. Statistically, the gap formation force and ultimate strength were the highest in the Tang, higher in the cruciate, and the lowest for the Robertson and the modified Kessler methods. The elastic modulus of the repaired tendons, as represented by the linear slope of the force-displacement curve, was also statistically the largest in the Tang, larger in the cruciate, and lowest for the Robertson and modified Kessler methods. Energy to failure was statistically the largest in the Tang, higher in the cruciate, lower in the Silfverskiold and the Robertson, and the lowest for the modified Kessler methods. It was concluded that significant differences exist in mechanical properties of the newly developed tendon suture methods. Among the methods for tendon repair that were tested, the Tang and the cruciate sutures were the best candidates for flexor tendon repair in the hand with postoperative active mobilization because of their superior tensile strength, elastic properties, energy to failure, and reasonable operation time.  相似文献   

14.
Tendon has been shown to undergo remodeling in response to strength or endurance training, however, compared to muscle, studies of the effects of exercise on tendon are limited and the information is inconsistent. Exercise may influence the structure, chemical composition and/or mechanical properties of tendon. Studies that have examined mechanical changes of tendon in response to endurance training suggest that ultimate failure strength and stiffness increase with training. Available reports indicate that increases in tensile strength and stiffness are probably not associated with increases in collagen concentration or with tendon hypertrophy. The paucity of data renders it impossible to evaluate the response of other structural, chemical and mechanical parameters to training. Furthermore, few investigators have included discrete measures of structural, biomechanical and biochemical variables within a single study. The lack of integrative studies makes it difficult to definitively associate changes in the mechanical properties of tendon with chemical composition and structure.  相似文献   

15.
The linear organization of collagen fibers in tendons results in optimal stiffness and strength at low strains under tensile load. However, this organization makes repairing ruptured or lacerated tendons extremely difficult. Current suturing techniques to join split ends of tendons, while providing sufficient mechanical strength to prevent gapping, are inadequate to carry normal loads. Immobilization protocols necessary to restore tendon congruity result in scar formation at the repair site and peripheral adhesions that limit excursion. These problems are reviewed to emphasize the need for novel approaches to tendon repair, one of which is the development of biomimetic tendons. The objective of the empirical work described here was to produce biologically-based, biocompatible tendon replacements with appropriate mechanical properties to enable immediate mobilization following surgical repair. Nor-dihydroguaiaretic acid (NDGA), a di-catechol from creosote bush, caused a dose dependent increase in the material properties of reconstituted collagen fibers, achieving a 100-fold increase in strength and stiffness over untreated fibers. The maximum tensile strength of the optimized NDGA treated fibers averaged 90 MPa; the elastic modulus of these fibers averaged 580 MPa. These properties were independent of strain rates ranging from 0.60 to 600 mm/min. Fatigue tests established that neither strength nor stiffness were affected after 80 k cycles at 5% strain. Treated fibers were not cytotoxic to tendon fibroblasts. Fibroblasts attached and proliferated on NDGA treated collagen normally. NDGA-fibers did not elicit a foreign body response nor did they stimulate an immune reaction during six weeks in vivo. The fibers survived 6 weeks with little evidence of fragmentation or degradation. The polymerization scheme described here produces a fiber-reinforced NDGA-polymer with mechanical properties approaching an elastic solid. The strength, stiffness and fatigue properties of the NDGA-treated fibers are comparable to those of tendon. These fibers are biocompatible with tendon fibroblasts and elicit little rejection or antigenic response in vivo. These results indicate that NDGA polymerization may provide a viable approach for producing collagenous materials that can be used to bridge gaps in ruptured or lacerated tendons. The tendon-like properties of the NDGA-fiber would allow early mobilization after surgical repair. We predict that timely loading of parted tendons joined by this novel biomaterial will enhance mechanically driven production of neo-tendon by the colonizing fibroblasts and result in superior repair and rapid return to normal properties.  相似文献   

16.
The purpose of this study is to investigate age-dependent changes in the architecture and mechanical properties of tendon in TGF-beta inducible early gene-1 (TIEG) knockout mice. Wild-type and TIEG knockout mice, aged 1, 2, and 15 mo, were used. The mechanical properties of tail tendons isolated from these mice were determined using uniaxial tensile ramp (0.05 mm/s) and relaxation (5 mm/s) tests, with a strain of 10%. Mechanical parameters (Young's modulus from the ramp test; fast and static stresses from the relaxation test) were measured and recorded. The structure of the tail tendon fascicle was characterized by transmission electron microscopy. The results of the mechanical testing revealed no significant difference between the knockout and wild-type groups at 1 or 15 mo of age. However, the fascicles of the knockout mice at 3 mo of age exhibited decreased fast and static stresses compared with those of the wild-type mice. Electron microscopy revealed an increase in fibril size in the knockout mouse tendons relative to wild-type controls at 1 and 3 mo of age. These data indicate an important role for TIEG in tendon microarchitecture and strength in adult mice.  相似文献   

17.
Patellar tendon auto- and allo-grafts are commonly used in orthopedic surgery for reconstruction of the anterior cruciate ligaments (ACL). Autografts are mainly used for primary reconstruction, while allografts are useful for revision surgery. To avoid the risk of infectious disease transmission allografts should be radiation-sterilised. As radiation-sterilisation supposedly decreases the mechanical strength of tendon it is important to establish methods of allograft preservation and sterilisation assuring the best quality of grafts and their safety at the same time. Therefore, the purpose of this study was to compare the tensile strength of human patellar tendon (cut out as for ACL reconstruction), preserved by various methods (deep fresh freezing, glycerolisation, lyophilisation) and subsequently radiation-sterilised with doses of 0, 25, 50 or 100 kGy. Bone-Tendon-Bone grafts (BTB) were prepared from cadaveric human patella tendons with both patellar and tibial attachments. BTB grafts were preserved by deep freezing, glycerolisation or lyophilisation and were subsequently radiation-sterilised with doses of 0 (control), 25, 50 or 100 kGy. All samples were subjected to mechanical failure tensile tests with the use of Instron system in order to estimate their mechanical properties. All lyophilised grafts were rehydrated before performing of those tests. Obtained mechanical tests results of examined grafts suggest that deep-frozen irradiated grafts retain their initial mechanical properties to an extent which does not exclude their clinical application. All conducted experiments were approved by the Local Ethical Committee.  相似文献   

18.
Structural stability of the extracellular matrix is primarily a consequence of fibrillar collagen and the extent of cross-linking. The relationship between collagen self-assembly, consequent fibrillar shape and mechanical properties remains unclear. Our laboratory developed a model system for the preparation of self-assembled type I collagen fibers with fibrillar substructure mimicking the hierarchical structures of tendon. The present study evaluates the effects of pH and temperature during self-assembly on fibrillar structure, and relates the structural effects of these treatments on the uniaxial tensile mechanical properties of self-assembled collagen fibers. Results of the analysis of fibril diameter distributions and mechanical properties of the fibers formed under the different incubation conditions indicate that fibril diameters grow via the lateral fusion of discrete approximately 4 nm subunits, and that fibril diameter correlates positively with the low strain modulus. Fibril diameter did not correlate with either the ultimate tensile strength or the high strain elastic modulus, which suggests that lateral aggregation and consequently fibril diameter influences mechanical properties during small strain mechanical deformation. We hypothesize that self-assembly is mediated by the formation of fibrillar subunits that laterally and linearly fuse resulting in fibrillar growth. Lateral fusion appears important in generating resistance to deformation at low strain, while linear fusion leading to longer fibrils appears important in the ultimate mechanical properties at high strain.  相似文献   

19.
The effect of a lathyritic diet on the sensitivity of tendon to strain rate   总被引:1,自引:0,他引:1  
While the tensile failure properties of rat-tail tendon depend on strain rate, the sensitivity to strain rate decreases with age, especially during sexual maturation. The object of this study was to determine the effect of an experimental model of chronic lathyrism on age-dependent changes in the sensitivity of developing tendon strength to strain rate. Tensile failure experiments were conducted at high and low strain rate on tendons excised from test and control animals aged 1 to 6 mo. The tensile "yield" response of tendon was significantly affected by the diet resulting in a reduced tensile strength and failure strain. While the sensitivity of tendon failure to strain rate was slightly elevated by the experimental diet, age-dependent changes compared with controls. Since the diet supplement is thought to inhibit covalent crosslinking of collagen in the developing tendon, other factors are likely responsible for decrease in the sensitivity of tendon strength to strain rate during maturation.  相似文献   

20.
Effects of cyclic stress on the mechanical properties of collagen fascicles were studied by in vitro tissue culture experiments. Collagen fascicles (approximately 300 microns in diameter) obtained from the rabbit patellar tendon were applied cyclic load at 4 Hz for one hour per day during culture period for one or two weeks, and then their mechanical properties were determined using a micro-tensile tester. There was a statistically significant correlation between tensile strength and applied peak stress in the range of 0 to 5 MPa, and the relation was expressed by a quadratic function. The maximum strength (19.4 MPa) was obtained at the applied peak stress of 1.8 MPa. The tensile strength of fascicles were within a range of control values, if they were cultured under peak stresses between 1.1 and 2.6 MPa. Similar results were also observed in the tangent modulus, which was maintained at control level under applied peak stresses between 0.9 and 2.8 MPa. The stress of 0.9 to 1.1 MPa is equivalent to approximately 40% of the in vivo peak stress which is developed in the intact rabbit patellar tendon by running, whereas that of 2.6 to 2.8 MPa corresponds to approximately 120% of the in vivo peak stress. Therefore, the fascicles cultured under applied peak stresses of lower than 40% and higher than 120% of the in vivo peak stress do not keep the original strength and modulus. These results indicate that the mechanical properties of cultured collagen fascicles strongly depend upon the magnitude of the stress applied during culture, which are similar to our previous results observed in stress-shielded and overstressed patellar tendons in vivo.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号