1.
The measurement of blood velocity fields, volume flow, and arterial wall motion in the descending thoracic aorta provides essential hemodynamic information for both research and clinical diagnosis. The close proximity of the esophagus to the aorta in the dog makes it possible to obtain such data nonsurgically using an ultrasonic esophageal probe; however, the accuracy of such a probe is limited if the angle between the sound beam and the flow axis, known as the Doppler angle, is not precisely known. By use of a pulsed Doppler velocity meter (PUDVM) and a triangulation procedure, accurate empirical measurement of the Doppler angle has been obtained, allowing quantification of blood velocity scans across the aorta. Volume flow is obtained by integration of blood velocity profiles and arterial wall motion is measured with an ultrasonic echo tracking device. Accuracy of the probe was substantiated by comparison with ultrasonic and electromagnetic implanted flow cuff measurements. Use of the probe in measurement of blood velocity, volume flow and arterial wall motion at various locations along the 8- and 10-cm length of the descending thoracic aorta in adult beagle dogs is detailed. The simplicity, accuracy, and nontraumatic aspect of the technique should allow increasing use of such a probe in numerous research and clinical applications.  相似文献   

2.
For the purpose of improving accuracy of noninvasive flow measurements in small (1–2 mm diameter) blood vessels, an existing 20 MHz pulsed ultrasound Doppler velocimeter (PUDVM) has been augmented to allow fast Fourier transformation (FFT) of its Doppler shift signal. The modified instrument was used to collect velocity spectra for a benchtop test section delivering precise Poiseuille flows at velocities in the range of physiological interest. The velocity spectra demonstrated a substantial degree of broadening, much of which was attributable to the geometry of the finite sample volume size. Several spectral indices were studied as a function of flow field variables. Results showed that the intensity-weighted mean Doppler shift frequency, when converted to its corresponding velocity vM, agreed very closely with the theoretically predicted local fluid velocity. Measurement linearity and repeatability were evaluated for a number of system variables, indicating that FFT performance was essentially unaffected by several parameters capable of causing major degradation of (phasic) Doppler shift signals produced by conventional zero-crossing-counter circuitry. As presently configured, the augmented PUDVM instrument is fully capable of detailed flow field mapping in small subcutaneous vessels such as human digital arteries.  相似文献   

3.
Pulsed ultrasound Doppler velocity meters (PUDVM) permit noninvasive blood velocity measurements. The emitted ultrasound beam characteristics primarily determine the resolution of the instrument when recording velocity profiles. The sample volume, the small region over which velocity information data are detected, was found to be > 2·3 mm3 depending on the transducer disk dia., distance in front of the disk, sampling time increment, and pulse length. The shape of the sample volume approximates a cylinder in the near field and a frustrum of a cone in the far field. The end surfaces of the sample volume were affected by the emitted pulse shape. Ultrasonic beam cross-sections were found to be smaller than predicted by theory due to the finite threshold levels of the PUDVM. The variation of the sample volume with range was illustrated by steady laminar flow velocity profile measurements in rigid tubes. The accuracy of velocity measurements was within 5 per cent with slightly larger deviations occurring near the walls due to the finite sample volume.  相似文献   

4.
A validation study and early results for non-invasive, in vivo measurement of coronary artery blood flow using phase contrast magnetic resonance imaging (PC-MRI) at 3.0T is presented. Accuracy of coronary artery blood flow measurements by phase contrast MRI is limited by heart and respiratory motion as well as the small size of the coronary arteries. In this study, a navigator echo gated, cine phase velocity mapping technique is described to obtain time-resolved velocity and flow waveforms of small diameter vessels at 3.0T. Phantom experiments using steady, laminar flow are presented to validate the technique and show flow rates measured by 3.0T phase contrast MRI to be accurate within 15% of true flow rates. Subsequently, in vivo scans on healthy volunteers yield velocity measurements for blood flow in the right, left anterior descending, and left circumflex arteries. Measurements of average, cross-sectional velocity were obtainable in 224/243 (92%) of the cardiac phases. Time-averaged, cross-sectional velocity of the blood flow was 6.8+/-4.3cm/s in the LAD, 8.0+/-3.8cm/s in the LCX, and 6.0+/-1.6cm/s in the RCA.  相似文献   

5.
《Biorheology》1996,33(3):185-208
An analytical solution for pulsatile flow of a generalized Maxwell fluid in straight rigid tubes, with and without axial vessel motion, has been used to calculate the effect of blood viscoelasticity on velocity profiles and shear stress in flows representative of those in the large arteries. Measured bulk flow rate Q waveforms were used as starting points in the calculations for the aorta and femoral arteries, from which axial pressure gradient ▿P waves were derived that would reproduce the starting Q waves for viscoelastic flow. The ▿P waves were then used to calculate velocity profiles for both viscoelastic and purely viscous flow. For the coronary artery, published ▿P and axial vessel acceleration waveforms were used in a similar procedure to determine the separate and combined influences of viscoelasticity and vessel motion.Differences in local velocities, comparing viscous flow to viscoelastic flow, were in all cases less than about 2% of the peak local velocity. Differences in peak wall shear stress were less than about 3%.In the coronary artery, wall shear stress differences between viscous and viscoelastic flow were small, regardless of whether axial vessel motion was included. The shape of the wall shear stress waveform and its difference, however, changed dramatically between the stationary and moving vessel cases. The peaks in wall shear stress difference corresponded with large temporal gradients in the combined driving force for the flow.  相似文献   

6.

Background

The detection of regional wall motion abnormalities is the cornerstone of stress echocardiography. Today, stress echo shows increasing trends of utilization due to growing concerns for radiation risk, higher cost and stronger environmental impact of competing techniques. However, it has also limitations: underused ability to identify factors of clinical vulnerability outside coronary artery stenosis; operator-dependence; low positivity rate in contemporary populations; intermediate risk associated with a negative test; limited value of wall motion beyond coronary artery disease. Nevertheless, stress echo has potential to adapt to a changing environment and overcome its current limitations.

Integrated-quadruple stress-echo

Four parameters now converge conceptually, logistically, and methodologically in the Integrated Quadruple (IQ)-stress echo. They are: 1- regional wall motion abnormalities; 2-B-lines measured by lung ultrasound; 3-left ventricular contractile reserve assessed as the stress/rest ratio of force (systolic arterial pressure by cuff sphygmomanometer/end-systolic volume from 2D); 4- coronary flow velocity reserve on left anterior descending coronary artery (with color-Doppler guided pulsed wave Doppler). IQ-Stress echo allows a synoptic functional assessment of epicardial coronary artery stenosis (wall motion), lung water (B-lines), myocardial function (left ventricular contractile reserve) and coronary small vessels (coronary flow velocity reserve in mid or distal left anterior descending artery). In “ABCD” protocol, A stands for Asynergy (ischemic vs non-ischemic heart); B for B-lines (wet vs dry lung); C for Contractile reserve (weak vs strong heart); D for Doppler flowmetry (warm vs cold heart, since the hyperemic blood flow increases the local temperature of the myocardium). From the technical (acquisition/analysis) viewpoint and required training, B-lines are the kindergarten, left ventricular contractile reserve the primary (for acquisition) and secondary (for analysis) school, wall motion the university, and coronary flow velocity reserve the PhD program of stress echo.

Conclusion

Stress echo is changing. As an old landline telephone with only one function, yesterday stress echo used one sign (regional wall motion abnormalities) for one patient with coronary artery disease. As a versatile smart-phone with multiple applications, stress echo today uses many signs for different pathophysiological and clinical targets. Large scale effectiveness studies are now in progress in the Stress Echo2020 project with the omnivorous “ABCD” protocol.
  相似文献   

7.
With the growth of genetic engineering, mice have become increasingly common as models of human diseases, and this has stimulated the development of techniques to assess the murine cardiovascular system. Our group has developed nonimaging and dedicated Doppler techniques for measuring blood velocity in the large and small peripheral arteries of anesthetized mice. We translated technology originally designed for human vessels for use in smaller mouse vessels at higher heart rates by using higher ultrasonic frequencies, smaller transducers, and higher-speed signal processing. With these methods one can measure cardiac filling and ejection velocities, velocity pulse arrival times for determining pulse wave velocity, peripheral blood velocity and vessel wall motion waveforms, jet velocities for the calculation of the pressure drop across stenoses, and left main coronary velocity for the estimation of coronary flow reserve. These noninvasive methods are convenient and easy to apply, but care must be taken in interpreting measurements due to Doppler sample volume size and angle of incidence. Doppler methods have been used to characterize and evaluate numerous cardiovascular phenotypes in mice and have been particularly useful in evaluating the cardiac and vascular remodeling that occur following transverse aortic constriction. Although duplex ultrasonic echo-Doppler instruments are being applied to mice, dedicated Doppler systems are more suitable for some applications. The magnitudes and waveforms of blood velocities from both cardiac and peripheral sites are similar in mice and humans, such that much of what is learned using Doppler technology in mice may be translated back to humans.  相似文献   

8.
Ultrasound techniques for measurement of blood flow and tissue motion   总被引:2,自引:0,他引:2  
Hoskins PR 《Biorheology》2002,39(3-4):451-459
This article will review the ability of ultrasound techniques to provide 3D information on arterial geometry, blood flow and tissue motion.3D systems. 3D datasets can be obtained by sequential acquisition of 2D slices. Ideally a transducer is required in which there is full control of beam steering within a 3D volume. This requires a 2D array consisting of several thousand elements. Prototype 2D arrays have been built which provide several 3D datasets per second.Blood velocity measurement. Current Doppler systems estimate only the component of velocity in the direction of the Doppler beam. Lack of knowledge of the direction of blood motion and also other effects associated with 'spectral broadening' limit the accuracy of velocity measurement. Improved accuracy can be obtained using vector Doppler systems using 2 or 3 beam directions; this approach is referred to as 'vector Doppler'.Tissue motion. Doppler techniques can also be used to detect tissue motion (Tissue Doppler Imaging or TDI). Motion of the artery wall can be calculated from the TDI images. It is possible to estimate simultaneously motion for adjacent diameters within the longitudinal plane, and to visualise the relative motion at different parts of the wall.  相似文献   

9.
Coronary flow reserve (CFR) is an important index of coronary microcirculatory function. The objective of this study was to validate the reproducibility and accuracy of intravascular conductance catheter-based method for measurements of baseline and hyperemic coronary flow velocity (and hence CFR). The absolute coronary blood velocity was determined by measuring the time of transit of a saline injection between two pairs of electrodes (known distance) on a conductance catheter during a routine saline injection without the need for reference flow. In vitro validation was made in the velocity range of 5 to 70 cm/s in reference to the volume collection method. In 10 swine, velocity measurements were compared with those from a flow probe in coronary arteries at different CFR attained by microsphere embolization. In vitro, the mean difference between the proposed method and volume collection was 0.7 ± 1.34 cm/s for steady flow and -0.77 ± 2.22 cm/s for pulsatile flow. The mean difference between duplicate measurements was 0 ± 1.4 cm/s. In in vivo experiments, the flow (product of velocity and lumen cross-sectional area that is also measured by the conductance catheter) was determined in both normal and stenotic vessels and the mean difference between the proposed method and flow probe was -1 ± 12 ml/min (flow ranged from 10 to 130 ml/min). For CFR, the mean difference between the two methods was 0.06 ± 0.28 (range of 1 to 3). Our results demonstrate the reproducibility and accuracy of velocity and CFR measurements with a conductance catheter by use of a standard saline injection. The ability of the combined measurement of coronary lumen area (as previously validated) and current velocity and CFR measurements provides an integrative diagnostic tool for interventional cardiology.  相似文献   

10.
Recent applications of 20 MHz pulsed ultrasound Doppler velocimetry (PUDVM) in microsurgical research have necessarily employed piezoelectric crystals whose diameter is not negligible compared to the lumen size (1-2 mm) of many vessels of interest. A three-dimensional numerical model was developed to explore relationships between actual and detected flow field parameters, for (steady) Poiseuille flow, when appreciable velocity gradients exist within the PUDVM sample volume. Validation studies showed that highly accurate velocity profiles could be obtained in the limiting case of a very small sample volume (0.1 mm radius), but that for currently employed crystals (approximately equal to 0.5 mm radius) there was appreciable underestimation of the centersteam velocity, and appreciable overestimation of the flow stream diameter. Errors in perceived velocity and flow rate were found to be relatively insensitive to perturbations in the sample volume thickness, in the size of the sampling range increment, or in the angle of insonation beam divergence. By contrast, these apparent flow parameters were found to be very sensitive to perturbations of sample volume diameter or of the Doppler angle. Small variations in the degree of partial sample volume overlap of the flowstream periphery were shown to be capable of causing large fluctuations in apparent flow stream diameter.  相似文献   

11.
The basic laws of blood screw motion in common carotid arteries in people were determined by means of modern ultrasound techniques for the first time. 92 healthy adults, aged 18-30, were examined. The blood flow in the middle one-third of common carotid arteries was registered by means of Color Doppler Imaging and impulse Doppler with the help of ultrasound Medison 8000EX scanner by linear transducer of 5-9 MHz. The steady registration of blood screw motion in both common carotid arteries in Color Doppler Imaging regimen was observed in 54.3 % of cases. The direction of screw stream rotation in most cases (54%) was multi-directed: in the right common carotid artery it was right, in the left common carotid artery--left (48%), and in 6% of cases it was reverse. For 46% of cases blood rotation in both common carotid arteries was one-directed (26%--right, 20%--left). The velocity parameters of rotation component of blood motion were determined, maximum velocity being 19.68 +/- 5.84 cm/sec, minimum--4.57 +/- 2.89 cm/sec, average--7.48 +/- 2.49 cm/sec, angular--10.7 +/- 2.49 sec(-1). The rated velocity of blood cells motion in screw motion with regard of screw current lines to the vessel vertical axis makes up from 158.67 +/- 32.79 to 224.39 +/- 46.37 cm/sec.  相似文献   

12.
We have developed a method for monitoring regional venous oxygen saturation. The key feature of this system is the use of highly flexible polymer fiber optics, and this flexibility allowed the production of a new fiber-optic transmission catheter. The space between the "face-to-face" positioned fiber-optic tips forms a remote catheter-based transmission cell. Our method applies Twersky's theory, in which absorption and scattering can be treated independently. Fresh rabbit blood was pumped through a disk oxygenator in which gas exchange occurred and passed the catheter. Simultaneous results obtained by the catheter and a cuvette oximeter were excellent (r = 0.99, SD = 1.1%). Oxygen saturation measured by this catheter was independent of vessel wall artifacts, blood pH, and flow velocity. Another application of this method is measurement of blood flow by the dye- (indocyanine green) dilution technique. The results of flow measurements by the catheter appeared to be satisfactory (r = 0.99, SD = 1.7%). This study concludes that our method is effective for monitoring the balance between regional oxygen supply and demand.  相似文献   

13.
The presence of atherosclerotic plaques has been shown to be closely related to the vessel geometry. Studies on postmortem human arteries and on the experimental animal show positive correlation between the presence of plaque thickness and low shear stress, departure of unidirectional flow and regions of flow separation and recirculation. Numerical simulations of arterial blood flow and direct blood flow velocity measurements by magnetic resonance imaging (MRI) are two approaches for the assessment of arterial blood flow patterns. In order to verify that both approaches give equivalent results magnetic resonance velocity data measured in a compliant anatomical carotid bifurcation model were compared to the results of numerical simulations performed for a corresponding computational vessel model. Cross sectional axial velocity profiles were calculated and measured for the midsinus and endsinus internal carotid artery. At both locations a skewed velocity profile with slow velocities at the outer vessel wall, medium velocities at the side walls and high velocities at the flow divider (inner) wall were observed. Qualitative comparison of the axial velocity patterns revealed no significant differences between simulations and in vitro measurements. Even quantitative differences such as for axial peak flow velocities were less than 10%. Secondary flow patterns revealed some minor differences concerning the form of the vortices but maximum circumferential velocities were in the same range for both methods.  相似文献   

14.
The pulsatile flow of blood through arteries is investigated in this paper by treating the blood vessel as a thin-walled anisotropic, non-linearly viscoelastic, incompressible circular cylindrical shell; nonlinearities of the flow of blood are also paid due consideration. The displacement components of the vessel wall are obtained from the equations of equilibrium which have been linearized by employing the principle of superimposition of a small deformation on a state of known finite deformation. The influence of the wall deformation on the flow properties of blood, has been accounted for by considering suitably formulated continuity conditions. A finitedifference scheme is employed for solving the flow equations together with the boundary and initial conditions by using the locally measured values of pressure and pressure gradient. Numerical results obtained for the velocity profile of blood flowing in a canine middle descending thoracic aorta have been presented through figures.  相似文献   

15.
The influence of blood flow on the depositions and development of atherosclerotic lesions have been observed and described since the 19th century. Observations have shown that depositions correlate with regions of low wall shear stress. However, the exact correlations between depositions, vessel geometry and flow parameters are not yet known. The purpose of this study was the quantification of atherosclerosis risk factors in carotid bifurcation. This artery has attracted particular interest because lesions are often found in this bifurcation. Post mortem, the arteries are excised and vessel casts are produced. Afterwards, the arteries are analyzed morphometrically. The vessel casts are used for the assessment of some geometrical parameters. 31 carotid bifurcations were analyzed in this study. Eight vessel casts were digitized and rendered three-dimensional mathematical models of the arteries. These data were imported by the computational fluid dynamics program FLUENT. Further, the blood flow was reconstructed in a computer model based on the individual vessel geometry. The flow parameters, such as velocity, pressure and wall shear stress were computed. At the same time the geometrical parameters and wall alterations are known. This permits the comparison of the anatomical shape and its flow with the distribution and level of the wall alterations.  相似文献   

16.
The study of the ultrasound diameter, linear velocity, and resistance of the internal carotid arteries in 647 subjects of both sexes aged from 1 to 74 years has been performed. Additionally, shear stress and the Reynolds number have been calculated. During the period from early childhood to adolescence and from the first mature to younger elderly ages, there is an increase in the diameter of the internal carotid arteries. Phases of an increase in the vascular resistance by the first period of childhood, adolescence, and younger elderly age are observed. The space flow velocity has relatively stable parameters till youth, and then it declines by younger elderly age. The average linear velocity, shear stress, and the Reynolds number progressively diminish twice by younger elderly age. Laminar blood flow with local twists in the early stages of postnatal ontogenesis is characteristic of the internal carotid arteries. The diameter of the internal carotid arteries, vascular resistance index, and blood flow velocity are higher in men than in women during most age periods. Shear stress in both internal carotid arteries during all the age periods studied is symmetrical and has no sex differences.  相似文献   

17.
A mathematical model has been developed to study the effect of particle drag parameter and frequency parameter on velocity and pressure gradient in nonlinear oscillatory two phase flow. The main purpose is to apply the model to study the combined effect of introduction of the catheter and elastic properties of the arterial wall on the pulsatile nature of the blood flow. We model the artery as an isotropic thin walled elastic tube and the catheter as a coaxial flexible tube. Blood is modeled as an incompressible particulate viscous Newtonian fluid. Perturbation technique has been applied to find the approximations for velocity and pressure gradient up to second order. Numerical solutions are investigated with graphical presentations to understand the effects of drag parameter, frequency parameter and phase angle on velocity along radial direction and pressure gradient along axial directions. As the drag parameter increases, mean pressure gradient and mean velocity will be decreased. As frequency parameter increases mean velocity profile bends near the outer wall. Due to elastic nature of artery wall, a thin catheter experience small oscillations and a thick catheter remains stationary inside the artery. Finally, the effect of catheterization on various physiologically important flow rate characteristics—mean velocity, mean pressure gradient are studied for a range of different catheter sizes, particle drag parameter and frequency parameters.  相似文献   

18.
When a human being experiences a sudden velocity change, the blood flow is disturbed. A theoretical analysis to predict the effects of sudden velocity changes on blood flow in large arteries is presented. The situations is modelled as a one-dimensional flow problem in a viscoelastic tube where the fluid viscosity convective term in the equation of motion and nonlinearity in the elastic modulus of the tube wall are neglected. The governing equations of the model are solved by Laplace transformation. The computed results show that relatively high blood pressures, capable of harming circulation, are produced even by relatively moderate velocity jumps.  相似文献   

19.
Richardson PD 《Biorheology》2003,40(1-3):417-421
Relatively little attention has been given to vessel wall mechanics in interaction with the pulsatile fluid motion of blood in the epicardial coronary arteries which are prone to atherosclerotic plaque development. Theories for lipid transport by convective effects, while appealing in many ways, do not serve to explain the predominantly bounded, elliptic profiles of atherosclerotic plaques when examined en face at gross autopsy. This paper outlines how structural-mechanical concepts relating to plaque shapes (starting from the shapes available even with isometric shell peeling to create the cavities typical of early plaques) can be combined with understanding of the blood pressure distribution which develops in the vicinity of a predominantly T-junction in a blood vessel to modulate and interact in shape formation by cyclic, local flexure. This provides a foundation for a rational hypothesis to be tested in vivo with bi-plane angiography and vessel wall imaging, e.g., intravascular ultrasound, to better assess the roles of solid and fluid mechanics in the localization of plaques.  相似文献   

20.
A theoretical analysis of the flow in arteries is presented, taking into consideration the role played by the surrounding tissues in determining the speed of propagatoion and the damping of the blood pressure pulse. This study was undertaken (a) to exhibit a method of computing the flow properties with a more nearly accurate model, (b) to see if the displacement on the skin would be related to the arterial wall displacement, and hence to pressure, velocity and flow rate of blood in the artery, and if it is likely to be measurable. It was found that the pressure of the 'viscous' part in the surrounding tissue increases the pulse velocity and the damping of the wave over the values found by other models which considered only thick-walled elastic tubes with no surrounding tissue. This study also shows that measurements on the skin can provide information about changes in arterial circulation due to diseases such as: edema, arteriosclerosis and others where the Young's modulus for either the arterial wall or the surrounding tissues is altered.  相似文献   