首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 5 毫秒
1.
2.
3.
4.
5.
A noncontacting in vitro measurement of pulsatile arterial diameter using a scanning optical micrometer is described. The major component of this system is a He-Ne laser whose beam scans the pulsating artery to be measured. The laser micrometer was integrated into a pulsatile perfusion apparatus that imposed various hemodynamic conditions on excised canine vessels. The laser system reliably tracked the pulsating arterial diameter at a particular longitudinal site as well as at various increments in the presence of an experimentally created stenosis. The He-Ne laser measured the radial motion of canine arteries and various vascular substitutes anastomosed in an end-to-end fashion. From these novel measurements, calculations were made of arterial compliance and bending stress, two biomechanical parameters that are implicated as potential causes of anastomotic intimal hyperplasia and graft failure. Although this device is inherently limited to in vitro use, it is a potentially useful instrument for vascular physiology and biophysics.  相似文献   

6.
7.
Subterranean termites construct complex tunnel networks for foraging. During travel in the tunnels, termites often encounter one another when passing in opposite directions. Such encounters are likely to affect the “movement efficiency,” which is the time required for a termite to travel a certain distance in a tunnel. In this study, we explored how individual–individual encounters affect movement efficiency in tunnels by measuring the time (τ) taken by two termites to pass one another in tunnels of different curvatures. Artificial tunnels of 5 cm in length and variable widths (W) of 2, 3, or 4 mm were made. Tunnel distance (D) was 2, 3, 4, or 5 cm. When D had a higher value, curvature was lower. When W = 2, τ was significantly shorter in the tunnel with D = 5 than in tunnels of D = 2, 3, or 4, whereas τ was statistically the same for D = 2, 3 and 4. When W = 3, τ was shorter in the tunnel with D = 5 than for D = 3 and 4, while τ was longer in the tunnel with D = 2 than for D = 3 and 4. When W = 4, τ was longer in the tunnels with D = 2 and 3 than for D = 4 and 5. Based on these observations, 3 types of termite behavior were identified: biased walking, backward walking, and zigzag walking. We considered these results in relation to foraging efficiency.  相似文献   

8.
9.
We developed a new method for measuring tissue fluid pressure in subcutaneous tissue. Porous Teflon cylinders were permanently implanted subcutaneously into the inguinal area of 10 dogs, and after several weeks a skin concavity formed in the center of each of the cylinders. A small needle attached to a recording system was inserted into the free tissue fluid lining the concavity, and the tissue fluid pressure averaged -8.8 +/- 2.7 (SD) mmHg. Next, a hollow Plexiglas cup was placed over the concavity and glued to the skin. The air pressure in the skin cup was continually adjusted (using an electromechanical servo-control system) to pull the skin upward and to hold it perfectly flat across the upper ridge of the Teflon cylinder. The simultaneously recorded needle and cup pressures averaged -9.1 +/- 2.4 and -8.6 +/- 2.6 mmHg, respectively, during steady-state conditions with the skin in a flat position. Both pressures also responded appropriately to dynamic changes in tissue fluid pressure caused by increasing and decreasing the volume of the free tissue fluid. Because the skin was flat, the equivalences of pressures above and below the skin is consistent with the hypothesis that the skin was not tethered significantly to the underlying tissues and that cup pressure accurately estimates the tissue free fluid pressure.  相似文献   

10.
Y Asano  F Ariyuki 《Jikken dobutsu》1987,36(4):435-442
To investigate the usefulness of spontaneous motor activity (SMA) measurement using the vibrator response method, the acute effects of drugs on SMA were observed in Sprague-Dawley male rats. There were no significant differences between four devices. Methamphetamine (0.3-1 mg/kg, i.p.) and 1-2 mg/kg (s.c.) of apomorphine increased the SMA, but 0.05-0.2 mg/kg (s.c.) of apomorphine decreased the SMA. Apomorphine at 1-2 mg/kg (s.c.) significantly increased the SMA when the vibrator response method was used as compared with the Animex method. These results suggest that the vibrator response apparatus is useful for the measurement of SMA in rats.  相似文献   

11.
The venous occlusion technique was used to measure capillary pressure in the forearm and foot of man over a wide range of venous pressures. In six recumbent subjects venous pressure (Pv) in the forearm (mean +/- SE) was 9.3 +/- 1.4 mmHg and the venous occlusion estimate of capillary pressure (Pc) was 17.0 +/- 1.6 mmHg, whereas in another six subjects Pv in the foot was 17.1 +/- 1.2 mmHg and Pc was 23.4 +/- 2.5 mmHg. Venous pressure in the limbs was increased either by changes in posture or by venous congestion with a sphygmomanometer cuff. On standing Pv in the foot increased to 95.2 +/- 1.5 mmHg and Pc rose to 112.8 +/- 3.1 mmHg. The relationship established between venous pressure and capillary pressure in the forearm is Pc = 1.16 Pv + 8.1, whereas in the foot the relationship is Pc = 1.2 Pv + 1.6. The magnitude and duration of the changes in capillary pressure were also recorded during reactive hyperemia. The venous occlusion method of measuring capillary pressure is simple and easily applied to studies in humans.  相似文献   

12.
Abstract The rate of production of hydrogen by Clostridium butyricum was measured using a modified oxygraph equipment. As an example of the application of the method, some results of the investigations on the effect of short-chain volatile fatty acids on the metabolism of the organism are shown.  相似文献   

13.
14.
Zabaglo L  Ormerod MG  Dowsett M 《Cytometry》2000,41(3):166-171
BACKGROUND: A variety of markers, including Ki67, estrogen receptors (ER), and progesterone receptors (PgR), are frequently measured in fine needle aspirates (FNA) from human breast carcinomas. We used a human breast carcinoma cell line, MCF7, as a model system to investigate the use of laser scanning cytometry (LSC) for the measurement of these markers. Additionally, we measured the number of apoptotic cells. METHODS: Cells were treated with drugs to vary the expression of markers and the number of apoptotic cells. They were then fixed on microscope slides. For LSC, the cells were stained for the different markers with fluorescein using immunofluorescence and for apoptotic cells using the TUNEL assay. The nuclei were counterstained with propidium iodide. A parallel set of slides was stained using horseradish peroxidase and diaminobenzidine and scored manually by conventional light microscopy. RESULTS: The results from the LSC closely paralleled those obtained by manual scoring of immunohistochemical stains. CONCLUSIONS: It should be possible to use LSC for the routine measurement of nuclear markers in FNAs from human breast carcinomas.  相似文献   

15.
  • 1.1. The purpose of this study was to examine bone blood flow in various intra- and extra-oral sites.
  • 2.2. The radiolabelled microsphere method was utilized to assess osseous blood flow in the following regions of 10 dogs: rib, long bone, and anterior and posterior regions of the maxilla and mandible.
  • 3.3. Samples of cancellous and cortical bone were also obtained from each of these regions with the exception of the maxilla and the anterior mandible.
  • 4.4. Mean blood flow ranged from 3.71 ±0.81 (SE) ml min.−1 100 g−1 in the mandibular posterior cortical bone to 22.7±4.66ml min−1 100 g−1 in the cancellous rib samples.
  • 5.5. Blood flow to the cancellous tissue of the rib was significantly greater (P < 0.05 ) than the other tissues with the exception of maxillary posterior bone and cortical rib.
  • 6.6. Results from this study indicate that blood flow to the maxillary posterior bone is relatively high, but blood flow in other intraoral osseous sites is significantly less than that of cancellous rib bone.
  相似文献   

16.
17.
18.
A closed chamber method (CC-method) using an infra-red gas analyzer (IRGA) for measuring soil respiration was examined. Two major factors which potentially cause errors: (i) volume of air sampled from the chamber; and (ii) measuring period of time, were examined in laboratory experiments. Field measurements were also conducted with both the CC-method and the open-flow IRGA method (OF-method) throughout a year. The results of laboratory experiments showed that (i) sampling volume of air should be less than 0.2% of the volume of the chamber; and (ii) the air within the chamber should be sampled several times within 20 min. Field measurements showed that soil respiration rates measured by the CC-method were not significantly different from those by the OF-method. The results of this study indicate that the CC-method is as effective for the measurement of the soil respiration rates as the OF-method.  相似文献   

19.
We developed a method to measure hemoglobin synthesis rate (SynHb) in humans, assuming that free glycine in the red blood cell (RBC) represents free glycine in bone marrow for hemoglobin synthesis. The present rat study examines this assumption of the method and quantifies SynHb in rats. Sprague-Dawley rats (n = 9) were studied, [2-(13)C]glycine was intravenously infused over 24 h (2.5 mg kg(-1) h(-1)), blood was drawn for glycine and heme isolation, and bone marrow was harvested for glycine isolation. Isotopic enrichments of glycine and heme were measured, fractional hemoglobin synthesis rate (fSynHb% day(-1)) was calculated, and from this a value for SynHb (mg g(-1) day(-1)) was derived. Mean body weight was 446 +/- 10 g (mean +/- SE) and hemoglobin concentration was 14 +/- 0.5 g dl(-1). At 24 h, the mean isotopic enrichment, atom percentage excess (APE), of the RBC free glycine (1.56 +/- 0.18 APE) was similar to the bone marrow (1.68 +/- 0.15 APE). The rate of incorporation of (13)C into heme increased over time from 0.0004 APE/h between 6 and 12 h, to 0.0014 APE/h between 12 and 18 h, and 0.0024 APE/h between 18 and 24 h. Consequently, fSynHb (1.19 +/- 0.32, 2.92 +/- 0.66, and 4.22 +/- 0.56% day(-1), respectively) and SynHb (0.11 +/- 0.03, 0.28 +/- 0.05, and 0.42 +/- 0.05 mg g(-1) day(-1), respectively) showed similar patterns over the 24-h study period. We conclude that (1) enrichment of free glycine in the circulating RBC approximates enrichment of bone marrow free glycine for heme formation and (2) this pattern of hemoglobin synthesis rate is reflecting the characteristic release and gradual maturation of reticulocytes in the circulation.  相似文献   

20.
Kilner PJ  Yang GZ  Firmin DN 《Biorheology》2002,39(3-4):409-417
Through cardiac looping during embryonic development, human and other vertebrate hearts adopt sinuous curvatures with marked changes in direction of flow at atrial, ventricular and arterial levels. We used magnetic resonance phase velocity mapping to study flow through the hearts of resting volunteers, and Doppler ultrasound to record changes with exercise. We found asymmetric recirculation of blood during filling phases of all four heart cavities, with blood redirected appropriately for onward passage to the next cavity. Doppler traces showed that biphasic ventricular filling became rapid and monophasic on strenuous exercise. We propose that looped curvatures of the heart have fluidic and dynamic advantages. Intra-cavity flow appears to be asymmetric in a manner that preserves stability, and allows momentum of inflowing streams to be redirected towards rather than away from the next cavity. Direction-change at ventricular level is such that recoil away from ejected blood is in a direction that can enhance rather than inhibit ventriculo-atrial coupling. These factors may combine to allow a reciprocating, sling-like, 'morphodynamic' mode of action become effective when heart rate and output increase with exercise. Dynamic efficiency of the looped heart may have favoured evolution of large, complex, active species characteristic of the vertebrate line.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号