首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Selective separation of cells using dielectrophoresis (DEP) has recently been studied and methods have been proposed. However, these methods are not applicable to large‐scale separation because they cannot be performed efficiently. In DEP separation, the DEP force is effective only when it is applied close to the electrodes. Utilizing a DEP filter is a solution for large‐scale separation. In this article, the separation efficiency for viable and nonviable cells in a DEP filter was examined. The effects of an applied AC electric field frequency and the gradient of the squared electric field intensity on a DEP velocity for the viable and nonviable animal cells (3‐2H3 cell) were discussed. The frequency response of the DEP velocity differed between the viable and the nonviable cells. We deducted an empirical equation that can be used as guiding principle for the DEP separation. The results indicate that the viable and the nonviable cells were separated using the DEP filter, and the best operating conditions such as the applied voltage and the flow rate were discussed. © 2010 American Institute of Chemical Engineers Biotechnol. Prog., 2010  相似文献   

2.
The handling of individual cells, which has attracted increasing attention, is a key technique in cell engineering such as gene introduction, drug injection, and cloning technology. Alternating current (AC) electrokinetics has shown great potential for microfluidic functions such as pumping, mixing, and concentrating particles. The non-uniform electric field gives rise to Joule heating and dielectrophoresis (DEP). The motion of particles suspended in the medium can be influenced directly, by means of dielectrophoretic effects, and indirectly, via fluid flow through a viscous drag force that affects the particles. Thus alternating current electrothermal effect (ACET) induced flow and DEP force can be combined to manipulate and trap single particles and cells. This study presents a microfluidic device which is capable of specifically guiding and capturing single particles and cells by ACET fluid flow and the negative dielectrophoretic (nDEP) trap, respectively. The experiment was operated at high frequencies (5–12 MHz) and in a culture medium whose high conductivity (σ = 1.25 S/m) is of interest to biochemical analysis and environmental monitoring, which are both prone to producing ACET and nDEP. Manipulation of particle motion using ACET-induced fluid flow to the target trap is modeled numerically and is in good agreement with the experimental results.  相似文献   

3.
Dielectrophoresis (DEP) is the phenomenon by which polarized particles in a non-uniform electric field undergo translational motion, and can be used to direct the motion of microparticles in a surface marker-independent manner. Traditionally, DEP devices include planar metallic electrodes patterned in the sample channel. This approach can be expensive and requires a specialized cleanroom environment. Recently, a contact-free approach called contactless dielectrophoresis (cDEP) has been developed. This method utilizes the classic principle of DEP while avoiding direct contact between electrodes and sample by patterning fluidic electrodes and a sample channel from a single polydimethylsiloxane (PDMS) substrate, and has application as a rapid microfluidic strategy designed to sort and enrich microparticles. Unique to this method is that the electric field is generated via fluidic electrode channels containing a highly conductive fluid, which are separated from the sample channel by a thin insulating barrier. Because metal electrodes do not directly contact the sample, electrolysis, electrode delamination, and sample contamination are avoided. Additionally, this enables an inexpensive and simple fabrication process.cDEP is thus well-suited for manipulating sensitive biological particles. The dielectrophoretic force acting upon the particles depends not only upon spatial gradients of the electric field generated by customizable design of the device geometry, but the intrinsic biophysical properties of the cell. As such, cDEP is a label-free technique that avoids depending upon surface-expressed molecular biomarkers that may be variably expressed within a population, while still allowing characterization, enrichment, and sorting of bioparticles.Here, we demonstrate the basics of fabrication and experimentation using cDEP. We explain the simple preparation of a cDEP chip using soft lithography techniques. We discuss the experimental procedure for characterizing crossover frequency of a particle or cell, the frequency at which the dielectrophoretic force is zero. Finally, we demonstrate the use of this technique for sorting a mixture of ovarian cancer cells and fluorescing microspheres (beads).  相似文献   

4.
A microfluidic electrochemical immunoassay system for multiplexed detection of protein cancer biomarkers was fabricated using a molded polydimethylsiloxane channel and routine machined parts interfaced with a pump and sample injector. Using off-line capture of analytes by heavily-enzyme-labeled 1 μm superparamagnetic particle (MP)-antibody bioconjugates and capture antibodies attached to an 8-electrode measuring chip, simultaneous detection of cancer biomarker proteins prostate specific antigen (PSA) and interleukin-6 (IL-6) in serum was achieved at sub-pg mL?1 levels. MPs were conjugated with ~90,000 antibodies and ~200,000 horseradish peroxidase (HRP) labels to provide efficient off-line capture and high sensitivity. Measuring electrodes feature a layer of 5 nm glutathione-decorated gold nanoparticles to attach antibodies that capture MP-analyte bioconjugates. Detection limits of 0.23 pg mL?1 for PSA and 0.30 pg mL?1 for IL-6 were obtained in diluted serum mixtures. PSA and IL-6 biomarkers were measured in serum of prostate cancer patients in total assay time 1.15 h and sensor array results gave excellent correlation with standard enzyme-linked immunosorbent assays (ELISA). These microfluidic immunosensors employing nanostructured surfaces and off-line analyte capture with heavily labeled paramagnetic particles hold great promise for accurate, sensitive multiplexed detection of diagnostic cancer biomarkers.  相似文献   

5.
Advances in microfabrication have introduced new possibilities for automated, high-throughput biomedical investigations and analysis. Physical effects such as dielectrophoresis (DEP) and AC electrokinetics can be used to manipulate particles in solution to coordinate a sequence of bioanalytical processing steps. DEP is accomplished with non-uniform electric fields that can polarize particles (microbeads, cells, viruses, DNA, proteins, etc.) in suspension causing translational or rotational movement. AC electrokinetics is another phenomena involved with movement of particles in suspension with electric fields and is comprised of both electro-thermal and electro-osmotic effects. This paper investigates single layer electrodes that are effective for particle localization and clustering based on DEP and AC electrokinetic effects. We demonstrate a novel multi-electrode setup capable of clustering particles into an array of discrete bands using activated and electrically floating electrodes. These bands shift to adjacent regions on the electrode surface by altering the electrode activation scheme. The predictability of particle placement to specific locations provides new opportunities for integration and coordination with raster scanning lasers or a charge coupled device (CCD) for advanced biomedical diagnostic devices, and more sophisticated optical interrogation techniques.  相似文献   

6.
Dielectrophoretic platforms for bio-microfluidic systems   总被引:2,自引:0,他引:2  
Dielectrophoresis, the induced motion of polarisable particles in a nonuniform electric field, has been proven as a versatile mechanism to transport, accumulate, separate and characterise micro/nano scale bioparticles in microfluidic systems. The integration of DEP systems into the microfluidics enables the inexpensive, fast, highly sensitive, highly selective and label-free detection and analysis of target bioparticles. This review provides an in-depth overview of state-of-the-art dielectrophoretic (DEP) platforms integrated into microfluidics aimed towards different biomedical applications. It classifies the current DEP systems in terms of different microelectrode configurations and operating strategies devised to generate and employ DEP forces in such processes, and compares the features of each approach. Finally, it suggests the future trends and potential applications of DEP systems in single cell analysis, stem cell research, establishing novel devices, and realising fully DEP-activated lab-on-a-chip systems.  相似文献   

7.
Dielectrophoretic (DEP) forces have been used extensively to manipulate, separate, and localize biological cells and bioparticles via high-gradient electric fields. However, minimization of DEP exposure time is desirable, because of possible untoward effects on cell behavior. Toward this goal, this article investigates the geometric and material determinants of particle patterning kinetics and efficiency. In particular, the time required to achieve a steady-state pattern is theoretically modeled and experimentally validated for a planar, interdigitated bar electrode array energized in a standing-wave configuration. This measure of patterning efficiency is calculated from an improved Fourier series solution of DEP force, in which realistic boundary conditions and a finite chamber height are imposed to reflect typical microfluidic applications. The chamber height, electrode spacing, and fluid viscosity and conductivity are parameters that profoundly affect patterning efficiency, and optimization can reduce electric field exposure by orders of magnitude. Modeling strategies are generalizable to arbitrary electrode design as well as to conditions where DEP force may not act alone to cause particle motion. This improved understanding of DEP patterning kinetics provides a framework for new advances in the development of DEP-based biological devices and assays with minimal perturbation of cell behavior.  相似文献   

8.
The study of the dielectric properties of micrometer- or nanometer-scale particles is of particular interest in present-day applications of biomedical engineering. Electrokinetics utilises electrically energised microelectrode structures within microfluidic chambers to noninvasively probe the physiological structure of live cancer cells. A system is described that combines the three complementary techniques of dielectrophoresis (DEP), travelling wave dielectrophoresis (TWD) and electrorotation (ROT) for the first time on a single, integrated chip (3 x 6 mm). The chip employs planar microelectrode arrays fabricated on a silicon substrate to facilitate the synthesis of the various nonuniform electric fields required for the controlled manipulation, measurement and characterization of mammalian cells. A study of the dielectric properties of human malignant cells (Daudi and NCI-H929) was performed to demonstrate the potential and the versatility of the system in providing a fully programmable microsystem.  相似文献   

9.
Our previous studies revealed that the dielectrophoresis method is effective for separating cells having different dielectric properties. The purpose of this study was to evaluate the separation characteristics of two kinds of cells by direct current (DC) voltage offset/alternating current (AC) voltage using an insulating porous membrane dielectrophoretic separator. The separation device gives dielectrophoretic (DEP) force and electrophoretic (EP) force to dispersed particles by applying the DC‐offset AC voltage. This device separates cells of different DEP properties by adopting a structure in which only the parallel plate electrodes and the insulating porous membrane are disposed in the flow path through which the cell‐suspension flows. The difference in the retention ratios of electrically homogeneous 4.5 μm or 20.0 μm diameter standard particles was a maximum of 82 points. Furthermore, the influences of the AC voltage or offset voltage on the retention ratios of mouse hybridoma 3‐2H3 cells and horse red blood cells (HRBC) were investigated. The difference in the retention ratio of the two kinds of cells was a maximum of 56 points. The separation efficiency of this device is expected to be improved by changing the device shape, number of pores, and pore placement. © 2016 American Institute of Chemical Engineers Biotechnol. Prog., 32:1292–1300, 2016  相似文献   

10.
For the purposes of a successful ex vivo gene therapy we have proposed and analyzed a new concept of an integrated microfluidic system for combined magnetic cell separation, electroporation, and magnetofection. For the analysis of magnetic and electric field distribution (given by Maxwell equations) as well as dynamics of magnetically labeled cell and transfection complex, we have used finite element method directly interfaced to the Matlab routine solving Newton dynamical equations of motion. Microfluidic chamber has been modeled as a channel with height and length 1 mm and 1 cm, respectively. Bottom electrode consisted of 100 parallel ferromagnetic straps and the upper electrode was plate of diamagnetic copper. From the dynamics of magnetic particle motion we have found that the characteristic time-scales for the motion of cells (mean capture time ~ 4 s) and gene complexes (mean capture time ~ 3 min), when permanent magnets are used, are in the range suitable for efficient cell separation and gene delivery. The largest electric field intensity (~10 kV/m) was observed at the edges of the microelectrodes, in the close proximity of magnetically separated cells, which is optimal for subsequent cell electroporation.  相似文献   

11.
In this study, a useful method was developed to fabricate array patterns of microparticles not on electrode surfaces, but on arbitrary surfaces, using negative‐dielectrophoresis (n‐DEP). First, electrodes were designed and electric field simulations were performed to manipulate microparticles toward target areas. Based on the simulation results, multilayered array and grid (MLAG) electrodes, consisting of array electrodes surrounded by insulated regions and a grid electrode, were fabricated for the formation of localized, non‐uniform electric fields. The MLAG electrode was mounted to a target substrate in a face‐to‐face configuration with a spacer. When an AC voltage (4.60 Vrms and 1 MHz) was applied to the MLAG electrode, array patterns of 6 and 20 µm diameter microparticles were rapidly fabricated on the target substrate with ease. The results suggest that MLAG electrodes can be widely applied for the fabrication of biochips including cell arrays. Biotechnol. Bioeng. 2009; 104: 709–718 © 2009 Wiley Periodicals, Inc.  相似文献   

12.
A number of approaches have been proposed and tested to transfer enzymatic reactions into the functional elements of microfluidic chips on the example of the bienzyme bioluminescent reaction involving NAD(P)H:FMN-oxidoreductase and luciferase. Measurement of the catalytic activity of these enzymes (under the influence of pollutants) is the basis of enzymatic bioassay of various liquids. It was found that all of the components of the reaction must be placed in the same cell of the chip to improve the reproducibility of the measurements. The use of starch gel as a carrier for immobilization and gelatin as a scaffold in the reactor of the chip enables the preservation of enzyme activity in the course of sealing the chip at room temperature. It is shown that the components of the reaction should be vigorously stirred in a microfluidic chip reactor to improve the efficiency of the analysis. As a result of the studies, a prototype of microfluidic chip based on the enzymatic bioluminescent reaction is proposed. It is characterized by a detection limit of copper sulfate of 3 μM that corresponds to the sensitivity of traditional lux-biosensors based on living cells. The analysis time is reduced to 1 min, and the analysis can be performed by individuals without special laboratory skills.  相似文献   

13.
Release of neurotransmitters and hormones by calcium regulated exocytosis is a fundamental cellular/molecular process that is disrupted in a variety of psychiatric, neurological, and endocrine disorders. Therefore, this area represents a relevant target for drug and therapeutic development, efforts that will be aided by novel analytical tools and devices that provide mechanistically rich data with increased throughput. Toward this goal, we have electrochemically deposited iridium oxide (IrOx) films onto planar thin film platinum electrodes (20 μm×300 μm) and utilized these for quantitative detection of catecholamine release from adrenal chromaffin cells trapped in a microfluidic network. The IrOx electrodes show a linear response to norepinephrine in the range of 0-400 μM, with a sensitivity of 23.1±0.5 mA/M mm(2). The sensitivity of the IrOx electrodes does not change in the presence of ascorbic acid, a substance commonly found in biological samples. A replica molded polydimethylsiloxane (PDMS) microfluidic device with nanoliter sensing volumes was aligned and sealed to a glass substrate with the sensing electrodes. Small populations of chromaffin cells were trapped in the microfluidic device and stimulated by rapid perfusion with high potassium (50mM) containing Tyrode's solution at a flow rate of 1 nL/s. Stimulation of the cells produced a rapid increase in current due to oxidation of the released catecholamines, with an estimated maximum concentration in the cell culture volume of ~52 μM. Thus, we demonstrate the utility of an integrated microfluidic network with IrOx electrodes for real-time quantitative detection of catecholamines released from small populations of chromaffin cells.  相似文献   

14.
Coskun AF  Sencan I  Su TW  Ozcan A 《PloS one》2011,6(1):e15955
We demonstrate lensfree on-chip fluorescent imaging of transgenic Caenorhabditis elegans (C. elegans) over an ultra-wide field-of-view (FOV) of e.g., >2-8 cm(2) with a spatial resolution of ~10 μm. This is the first time that a lensfree on-chip platform has successfully imaged fluorescent C. elegans samples. In our wide-field lensfree imaging platform, the transgenic samples are excited using a prism interface from the side, where the pump light is rejected through total internal reflection occurring at the bottom facet of the substrate. The emitted fluorescent signal from C. elegans samples is then recorded on a large area opto-electronic sensor-array over an FOV of e.g., >2-8 cm(2), without the use of any lenses, thin-film interference filters or mechanical scanners. Because fluorescent emission rapidly diverges, such lensfree fluorescent images recorded on a chip look blurred due to broad point-spread-function of our platform. To combat this resolution challenge, we use a compressive sampling algorithm to uniquely decode the recorded lensfree fluorescent patterns into higher resolution images, demonstrating ~10 μm resolution. We tested the efficacy of this compressive decoding approach with different types of opto-electronic sensors to achieve a similar resolution level, independent of the imaging chip. We further demonstrate that this wide FOV lensfree fluorescent imaging platform can also perform sequential bright-field imaging of the same samples using partially-coherent lensfree digital in-line holography that is coupled from the top facet of the same prism used in fluorescent excitation. This unique combination permits ultra-wide field dual-mode imaging of C. elegans on a chip which could especially provide a useful tool for high-throughput screening applications in biomedical research.  相似文献   

15.
Microfluidic chips have been widely used to probe the mechanical properties of cells, which are recognized as a promising label-free biomarker for some diseases. In our previous work (Ye et al., 2018), we have studied the relationships between the transit time and the mechanical properties of a cell flowing through a microchannel with a single constriction, which potentially forms a basis for a microfluidic chip to measure cell’s mechanical properties. Here, we investigate this microfluidic chip design and examine its potential in performances. We first develop the simultaneous dependence of the transit time on both the shear and bending moduli of a cell, and then examine the chip sensitivity with respect to the cell mechanical properties while serializing a single constriction along the flow direction. After that, we study the effect of the flow velocity on the transit time, and also test the chip’s ability to identify heterogeneous cells with different mechanical properties. The results show that the microfluidic chip designed is capable of identifying heterogeneous cells, even when only one unhealthy cell is included. The serialization of chip can greatly increase the chip sensitivity with respect to the mechanical properties of cells. The flow with a higher velocity helps in not only promoting the chip throughput, but also in providing more accurate transit time measurements, because the cell prefers a symmetric deformation under a high velocity.  相似文献   

16.
Platelet aggregation plays a central role in pathological thrombosis, preventing healthy physiological blood flow within the circulatory system. For decades, it was believed that platelet aggregation was primarily driven by soluble agonists such as thrombin, adenosine diphosphate and thromboxane A2. However, recent experimental findings have unveiled an intriguing but complementary biomechanical mechanism—the shear rate gradients generated from flow disturbance occurring at sites of blood vessel narrowing, otherwise known as stenosis, may rapidly trigger platelet recruitment and subsequent aggregation. In our Nature Materials 2019 paper [1], we employed microfluidic devices which incorporated micro-scale stenoses to elucidate the molecular insights underlying the prothrombotic effect of blood flow disturbance. Nevertheless, the rheological mechanisms associated with this stenotic microfluidic device are poorly characterized. To this end, we developed a computational fluid dynamics (CFD) simulation approach to systematically analyze the hemodynamic influence of bulk flow mechanics and flow medium. Grid sensitivity studies were performed to ensure accurate and reliable results. Interestingly, the peak shear rate was significantly reduced with the device thickness, suggesting that fabrication of microfluidic devices should retain thicknesses greater than 50 µm to avoid unexpected hemodynamic aberration, despite thicker devices raising the cost of materials and processing time of photolithography. Overall, as many groups in the field have designed microfluidic devices to recapitulate the effect of shear rate gradients and investigate platelet aggregation, our numerical simulation study serves as a guideline for rigorous design and fabrication of microfluidic thrombosis models.  相似文献   

17.
Contactless dielectrophoresis (cDEP) devices are a new adaptation of dielectrophoresis in which fluid electrodes, isolated from the main microfluidic channel by a thin membrane, provide the electric field gradients necessary to manipulate cells. This work presents a continuous sorting device which is the first cDEP design capable of exploiting the Clausius-Mossotti factor at frequencies where it is both positive and negative for mammalian cells. Experimental devices are fabricated using a cost effective technique which can achieve 50 μm feature sizes and does not require the use of a cleanroom or specialized equipment. An analytical model is developed to evaluate cDEP devices as a network of parallel resistor-capacitor pairs. Two theoretical devices are presented and evaluated using finite element methods to demonstrate the effect of geometry on the development of electric field gradients across a wide frequency spectrum. Finally, we present an experimental device capable of continuously sorting human leukemia cells from dilute blood samples. This is the first cDEP device designed to operate below 100 kHz resulting in successful manipulation of human leukemia cells, while in the background red blood cells are unaffected.  相似文献   

18.
X Tian  S Wang  Z Zhang  D Lv 《PloS one》2012,7(8):e42804
Numerous researches demonstrated the possibility of derivation of Schwann-like (SC-like) cells in vitro from bone marrow stromal cells (BMSCs). However, the concentration of the induce factors were different in those studies, especially for the critical factors forskolin (FSK) and β-heregulin (HRG). Here, we used a new and useful method to build an integrated microfluidic chip for rapid analyses of the optimal combination between the induce factors FSK and HRG. The microfluidic device was mainly composed of an upstream concentration gradient generator (CGG) and a downstream cell culture module. Rat BMSCs were cultured in the cell chambers for 11 days at the different concentrations of induce factors generated by CGG. The result of immunofluorescence staining on-chip showed that the group of 4.00 μM FSK and 250.00 ng/ml HRG presented an optimal effect to promote the derivation of SC-like cells. Moreover, the optimal SC-like cells obtained on-chip were further tested using DRG co-culture and ELISA to detect their functional performance. Our findings demonstrate that SC-like cells could be obtained with high efficiency and functional performance in the optimal inducers combination.  相似文献   

19.
SAW devices based on horizontally polarized surface shear waves (HPSSW) enable label-free, sensitive and cost-effective detection of biomolecules in real time. It is known that small sampling volumes with low inner surface areas and minimal mechanical stress arising from sealing elements of miniaturized sampling chambers are important in this field. Here, we present a new approach to integrate SAW devices with sampling chamber. The sensor device is encapsulated within a polymer chip containing fluid channel and contact points for fluidic and electric connections. The chip volume is only 0.9 microl. The polymeric encapsulation was performed tailor-made by Rapid Micro Product Development 3Dimensional Chip-Size-Packaging (RMPD 3D-CSP), a 3D photopolymerisation process. The polymer housing serves as tight and durable package for HPSSW biosensors and allows the use of the complete chips as disposables. Preliminary experiments with these microfluidic chips are shown to characterise the performance for their future applications as generic bioanalytical micro devices.  相似文献   

20.
The measurement of metabolic activity based on the extracellular acidification rate has attracted wide interests in the field of biochemical detection. In the study, the chip comprising a microfluid-controlled open container and iridium oxide (IrO(x)) pH ultramicroelectrodes (UMEs) was constructed for the purpose of in situ measurement of extracellular acidification rate. The feasible anodic depositing parameters of IrO(x) film were in the range of +0.53 to +0.8 V by means of exploring the electrochemical properties of alkaline Ir(IV) deposition solution. The IrO(x) pH UMEs electrodeposited for 300 cycles between 0 V and +0.6 V exhibited the near-super-Nernstian sensitivity of -68 to -76 mV/pH and the good stability with potential drifting of 11.7 mV within 24h. The design of the open container connected with a position-raised microchannel improved the sensing stability of IrO(x) pH UMEs, with the potential deviation of as low as 0.1 mV under the flow rate of 20 μl/min. The acidification rate of HeLa cells (2160 cells/mm(2)) repeatedly measured 5 times in the microfluidic chip showed the good reproducibility of 0.021±0.002 pH/min. Moreover, the chip can decrease the acidosis occurrence, a decrease of only 0.13-0.17 pH unit in 8 min interval, during the measurement of cellular metabolic activity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号