首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Increased femoral antetorsion leads to several gait deviations, and amongst others, an increased knee flexion was reported in mid and terminal stance. Therefore, the purpose of this retrospective study was to identify gait deviations caused by increased femoral antetorsion and to perform subgroup analyses based on sagittal knee kinematics. Patients with isolated, CT confirmed increased femoral antetorsion (n = 42) and age-matched typically developing children (TDC, n = 17) were included in this study. Patients were referred to gait analysis because of gait abnormalities going along with an increased femoral antetorsion ≥30°. Kinematic and kinetic data were recorded during 3D gait analysis and three valid gait cycles were analyzed. Principal component (PC) analysis was used to achieve data transformation. A linear mixed model was used to estimate the group effect of PC-scores of retained PCs explaining 90% of the cumulative variance. Group effects of PC-scores revealed that patients walked with more flexed hips and greater anterior pelvic tilt throughout the gait cycle. Knee flexion was increased in patients during mid and terminal stance. Increased frontal plane knee and hip joint moments were found for patients compared to TDC. Furthermore, dividing patients into two subgroups based on their sagittal knee kinematics showed that kinematic gait deviations were more pronounced in patients with higher femoral antetorsion, while deviations in joint moments were more pronounced in patients with lower femoral antetorsion. Increased femoral antetorsion showed alterations in all lower limb joints and may be not only a cosmetic problem. Therefore, 3D gait analysis should be used for clinical management and operative treatment should be considered depending on severity of gait deviations.  相似文献   

2.
Altered gait kinematics and kinetics are observed in patients with medial compartment knee osteoarthritis. Although various kinematic adaptations are proposed to be compensatory mechanisms that unload the knee, the nature of these mechanisms is presently unclear. We hypothesized that an increased toe-out angle during early stance phase of gait shifts load away from the knee medial compartment, quantified as the external adduction moment about the knee. Specifically, we hypothesized that by externally rotating the lower limb anatomy, primarily about the hip joint, toe-out gait alters the lengths of ground reaction force lever arms acting about the knee joint in the frontal and sagittal planes and transforms a portion of knee adduction moment into flexion moment. To test this hypothesis, gait data from 180 subjects diagnosed with medial compartment knee osteoarthritis were examined using two frames of reference. The first frame was attached to the tibia (reporting actual toe-out) and the second frame was attached to the laboratory (simulating no-toe-out). Four measures were compared within subjects in both frames of reference: the lengths of ground reaction force lever arms acting about the knee joint in the frontal and sagittal planes, and the adduction and flexion components of the external knee moment. The mean toe-out angle was 11.4 degrees (S.D. 7.8 degrees , range -2.2 degrees to 28.4 degrees ). Toe-out resulted in significant reductions in the frontal plane lever arm (-6.7%) and the adduction moment (-11.7%) in early stance phase when compared to the simulated no-toe-out values. These reductions were coincident with significant increases in the sagittal plane lever arm (+33.7%) and flexion moment (+25.0%). Peak adduction lever arm and moment were also reduced significantly in late stance phase (by -22.9% and -34.4%, respectively) without a corresponding increase in sagittal plane lever arm or flexion moment. These results indicate that toe-out gait in patients with medial compartment knee osteoarthritis transforms a portion of the adduction moment into flexion moment in early stance phase, suggesting that load is partially shifted away from the medial compartment to other structures.  相似文献   

3.
Musculoskeletal modeling and simulations have vast potential in clinical and research fields, but face various challenges in representing the complexities of the human body. Soft tissue artifact from skin-mounted markers may lead to non-physiological representation of joint motions being used as inputs to models in simulations. To address this, we have developed adaptive joint constraints on five of the six degree of freedom of the knee joint based on in vivo tibiofemoral joint motions recorded during walking, hopping and cutting motions from subjects instrumented with intra-cortical pins inserted into their tibia and femur. The constraint boundaries vary as a function of knee flexion angle and were tested on four whole-body models including four to six knee degrees of freedom. A musculoskeletal model developed in OpenSim simulation software was constrained to these in vivo boundaries during level gait and inverse kinematics and dynamics were then resolved. Statistical parametric mapping indicated significant differences (p < 0.05) in kinematics between bone pin constrained and unconstrained model conditions, notably in knee translations, while hip and ankle flexion/extension angles were also affected, indicating the error at the knee propagates to surrounding joints. These changes to hip, knee, and ankle kinematics led to measurable changes in hip and knee transverse plane moments, and knee frontal plane moments and forces. Since knee flexion angle can be validly represented using skin mounted markers, our tool uses this reliable measure to guide the five other degrees of freedom at the knee and provide a more valid representation of the kinematics for these degrees of freedom.  相似文献   

4.
The movement of the knee joint consists of a coupled motion between the tibiofemoral and patellofemoral articulations. This study measured the six degrees-of-freedom kinematics of the tibia, femur, and patella using dual-orthogonal fluoroscopy and magnetic resonance imaging. Ten normal knees from ten living subjects were investigated during weightbearing flexion from full extension to maximum flexion. The femoral and the patellar motions were measured relative to the tibia. The femur externally rotated by 12.9 deg and the patella tilted laterally by 16.3 deg during the full range of knee flexion. Knee flexion was strongly correlated with patellar flexion (R(2)=0.91), posterior femoral translation was strongly correlated to the posterior patellar translation (R(2)=0.87), and internal-external rotation of the femur was correlated to patellar tilt (R(2)=0.73) and medial-lateral patellar translation (R(2)=0.63). These data quantitatively indicate a kinematic coupling between the tibia, femur, and patella, and provide base line information on normal knee joint kinematics throughout the full range of weightbearing flexion. The data also suggest that the kinematic coupling of tibia, femur, and patella should be considered when investigating patellar pathologies and when developing surgical techniques to treat knee joint diseases.  相似文献   

5.
The accurate measurement of the in vivo knee joint kinematics in six degrees-of-freedom (6DOF) remains a challenge in biomedical engineering. We have adapted a dual fluoroscopic imaging system (DFIS) to investigate the various in vivo dynamic knee joint motions. This paper presents a thorough validation of the accuracy and repeatability of the DFIS system when used to measure 6DOF dynamic knee kinematics. First, the validation utilized standard geometric spheres made from different materials to demonstrate the capability of the DFIS technique to determine the object positions under changing speeds. The translational pose of the spheres could be recreated to less than 0.15±0.09 mm for velocities below 300 mm/s. Next, tantalum beads were inserted into the femur and tibia of two fresh frozen cadaver knees to compare the dynamic kinematics measured by matching knee models to the kinematics from the tantalum bead matching—a technique similar to Roentgen stereophotogrammetric analysis (RSA). Each cadaveric knee was attached to the crosshead of a tensile testing machine and vertically translated at a rate of 16.66 mm/s while images were captured with the DFIS. Subsequently, the tibia was held fixed and the femur manually flexed from full extension to 90° of flexion, as the DFIS acquired images. In vitro translation of the cadaver knee using the tensile testing machine deviated from predicted values by 0.08±0.14 mm for the matched knee models. The difference between matching the knee and tantalum bead models during the dynamic flexion–extension motion of the knee was 0.1±0.65°/s in flexion speed; 0.24±0.16 mm in posterior femoral translation; and 0.16±0.61° in internal–external tibial rotation. Finally, we applied the method to investigate the knee kinematics of a living subject during a step ascent and treadmill gait. High repeatability was demonstrated for the in vivo application. Thus, the DFIS provides an easy and powerful tool for accurately determining 6DOF positions of the knee when performing daily functional activities.  相似文献   

6.
Biomechanics of overground vs. treadmill walking in healthy individuals.   总被引:1,自引:0,他引:1  
The goal of this study was to compare treadmill walking with overground walking in healthy subjects with no known gait disorders. Nineteen subjects were tested, where each subject walked on a split-belt instrumented treadmill as well as over a smooth, flat surface. Comparisons between walking conditions were made for temporal gait parameters such as step length and cadence, leg kinematics, joint moments and powers, and muscle activity. Overall, very few differences were found in temporal gait parameters or leg kinematics between treadmill and overground walking. Conversely, sagittal plane joint moments were found to be quite different, where during treadmill walking trials, subjects demonstrated less dorsiflexor moments, less knee extensor moments, and greater hip extensor moments. Joint powers in the sagittal plane were found to be similar at the ankle but quite different at the knee and hip joints. Differences in muscle activity were observed between the two walking modalities, particularly in the tibialis anterior throughout stance, and in the hamstrings, vastus medialis and adductor longus during swing. While differences were observed in muscle activation patterns, joint moments and joint powers between the two walking modalities, the overall patterns in these behaviors were quite similar. From a therapeutic perspective, this suggests that training individuals with neurological injuries on a treadmill appears to be justified.  相似文献   

7.
It is believed that force feedback can modulate lower extremity extensor activity during gait. The purpose of this research was to determine the role of limb loading on knee extensor excitability during the late stance/early swing phase of gait in persons post-stroke. Ten subjects with chronic hemiparesis post-stroke participated in (1) seated isolated quadriceps reflex testing with ankle loads of 0–0.4N m/kg and (2) gait analysis on a treadmill with 0%, 20% or 40% body weight support. Muscle reflex responses were recorded from vastus lateralis (VL), rectus femoris (RF), and vastus medialis (VM) during seated testing. Knee kinematics and quadriceps activity during late stance/early swing phase of gait were compared across loading conditions. Although isolated loading of the ankle plantarflexors at 0.2 N m/kg reduced VM prolonged response (p = 0.04), loading did not alter any other measure of quadriceps excitability (all p > 0.08). During gait, the use of BWS did not influence knee kinematics (p = 0.18) or muscle activity (all p > 0.17) during late stance/early swing phase. This information suggests that load sensed at the ankle has minimal effect on the ipsilateral quadriceps of individuals post-stroke during late stance. It appears that adjusting limb loading during rehabilitation may not be an effective tool to address stiff-knee gait following stroke.  相似文献   

8.
The goal of this study was to identify which muscle activation patterns and gait features best predict the metabolic cost of inclined walking. We measured muscle activation patterns, joint kinematics and kinetics, and metabolic cost in sixteen subjects during treadmill walking at inclines of 0%, 5%, and 10%. Multivariate regression models were developed to predict the net metabolic cost from selected groups of the measured variables. A linear regression model including incline and the squared integrated electromyographic signals of the soleus and vastus lateralis explained 96% of the variance in metabolic cost, suggesting that the activation patterns of these large muscles have a high predictive value for metabolic cost. A regression model including only the peak knee flexion angle during stance phase, peak knee extension moment, peak ankle plantarflexion moment, and peak hip flexion moment explained 89% of the variance in metabolic cost; this finding indicates that kinematics and kinetics alone can predict metabolic cost during incline walking. The ability of these models to predict metabolic cost from muscle activation patterns and gait features points the way toward future work aimed at predicting metabolic cost when gait is altered by changes in neuromuscular control or the use of an assistive technology.  相似文献   

9.
Mechanical tuning of an ankle-foot orthosis (AFO) is important in improving gait in individuals post-stroke. Alignment and resistance are two factors that are tunable in articulated AFOs. The aim of this study was to investigate the effects of changing AFO ankle alignment on lower limb joint kinematics and kinetics with constant dorsiflexion and plantarflexion resistance in individuals post-stroke. Gait analysis was performed on 10 individuals post-stroke under four distinct alignment conditions using an articulated AFO with an ankle joint whose alignment is adjustable in the sagittal plane. Kinematic and kinetic data of lower limb joints were recorded using a Vicon 3-dimensional motion capture system and Bertec split-belt instrumented treadmill. The incremental changes in the alignment of the articulated AFO toward dorsiflexion angles significantly affected ankle and knee joint angles and knee joint moments while walking in individuals post-stroke. No significant differences were found in the hip joint parameters. The alignment of the articulated AFO was suggested to play an important role in improving knee joint kinematics and kinetics in stance through improvement of ankle joint kinematics while walking in individuals post-stroke. Future studies should investigate long-term effects of AFO alignment on gait in the community in individuals post-stroke.  相似文献   

10.
Treadmill has been broadly used in laboratory and rehabilitation settings for the purpose of facilitating human locomotion analysis and gait training. The objective of this study was to determine whether dynamic gait stability differs or resembles between the two walking conditions (overground vs. treadmill) among young adults. Fifty-four healthy young adults (age: 23.9 ± 4.7 years) participated in this study. Each participant completed five trials of overground walking followed by five trials of treadmill walking at a self-selected speed while their full body kinematics were gathered by a motion capture system. The spatiotemporal gait parameters and dynamic gait stability were compared between the two walking conditions. The results revealed that participants adopted a “cautious gait” on the treadmill compared with over ground in response to the possible inherent challenges to balance imposed by treadmill walking. The cautious gait, which was achieved by walking slower with a shorter step length, less backward leaning trunk, shortened single stance phase, prolonged double stance phase, and more flatfoot landing, ensures the comparable dynamic stability between the two walking conditions. This study could provide insightful information about dynamic gait stability control during treadmill ambulation in young adults.  相似文献   

11.
Researchers conduct gait analyses utilizing both overground and treadmill modes of running. Previous studies comparing these modes analyzed discrete variables. Recently, techniques involving quantitative pattern analysis have assessed kinematic curve similarity in gait. Therefore, the purpose of this study was to compare hip, knee and rearfoot 3-D kinematics between overground and treadmill running using quantitative kinematic curve analysis. Twenty runners ran at 3.35 m/s ± 5% during treadmill and overground conditions while right lower extremity kinematics were recorded. Kinematics of the hip, knee and rearfoot at footstrike and peak were compared using intraclass correlation coefficients. Kinematic curves during stance phase were compared using the trend symmetry method within each subject. The overall average trend symmetry was high, 0.94 (1.0 is perfect symmetry) between running modes. The transverse plane and knee frontal plane exhibited lower similarity (0.86-0.90). Other than a 4.5 degree reduction in rearfoot dorsiflexion at footstrike during treadmill running, all differences were ≤1.5 degrees. 17/18 discrete variables exhibited modest correlations (>0.6) and 8/18 exhibited strong correlations (>0.8). In conclusion, overground and treadmill running kinematic curves were generally similar when averaged across subjects. Although some subjects exhibited differences in transverse plane curves, overall, treadmill running was representative of overground running for most subjects.  相似文献   

12.
The knowledge of articular cartilage contact biomechanics in the knee joint is important for understanding the joint function and cartilage pathology. However, the in vivo tibiofemoral articular cartilage contact biomechanics during gait remains unknown. The objective of this study was to determine the in vivo tibiofemoral cartilage contact biomechanics during the stance phase of treadmill gait. Eight healthy knees were magnetic resonance (MR) scanned and imaged with a dual fluoroscopic system during gait on a treadmill. The tibia, femur and associated cartilage were constructed from the MR images and combined with the dual fluoroscopic images to determine in vivo cartilage contact deformation during the stance phase of gait. Throughout the stance phase of gait, the magnitude of peak compartmental contact deformation ranged between 7% and 23% of the resting cartilage thickness and occurred at regions with thicker cartilage. Its excursions in the anteroposterior direction were greater in the medial tibiofemoral compartment as compared to those in the lateral compartment. The contact areas throughout the stance phase were greater in the medial compartment than in the lateral compartment. The information on in vivo tibiofemoral cartilage contact biomechanics during gait could be used to provide physiological boundaries for in vitro testing of cartilage. Also, the data on location and magnitude of deformation among non-diseased knees during gait could identify where loading and later injury might occur in diseased knees.  相似文献   

13.
Newer designs of total knee arthroplasty (TKA), through the use of added degrees of constraint, attempt to provide a "guided motion" to restore more normal and predictable kinematics. Two such design philosophies are the posterior stabilised (PS) using a cam-post and the medial pivot (MP) concepts. Knee kinematics of 12 patients with a PS TKA, 13 subjects with a MP TKA and 10 normal subjects were compared. For kinematic assessment, patients underwent fluoroscopic assessment of the knee during a step-up exercise and deep knee bend. Fluoroscopic images were corrected for distortion and assessed using 3D model fitting to determine relative 3D motion, and a 2D method to measure the patellar tendon angle (PTA) as function of knee flexion. For the PS design the cam-post mechanism engaged between 70 degrees and 100 degrees flexion. Between extension and 50 degrees there was forward motion of the contact points. Beyond 60 degrees both condyles rolled moved posteriorly. The majority of the external rotation of the femur occurred between 50 degrees and 80 degrees . The PTA was lower than normal in extension and higher than normal in flexion. The MP exhibited no anterior movement throughout the rage of motion. The medial condyle moved minimally. The lateral contact point moved posteriorly from extension to flexion. The femur rotated externally throughout the range of flexion analysed. The PTA was similar to normal from extension to mid flexion and then higher than normal beyond to high flexion. The PS design fails to fully restrain paradoxical anterior movement and although the cam engages, it does not contribute significantly to overall rollback. The MP knee does not show significant anterior movement, the medial pivot concept appears to achieve near normal kinematics from extension to 50 degrees of knee flexion. However, the results show that at high flexion this design does not achieve normal knee kinematics.  相似文献   

14.
Quantifying the mechanical environment at the knee is crucial for developing successful rehabilitation and surgical protocols. Computational models have been developed to complement in vitro studies, but are typically created to represent healthy conditions, and may not be useful in modeling pathology and repair. Thus, the objective of this study was to create finite element (FE) models of the natural knee, including specimen-specific tibiofemoral (TF) and patellofemoral (PF) soft tissue structures, and to evaluate joint mechanics in intact and ACL-deficient conditions. Simulated gait in a whole joint knee simulator was performed on two cadaveric specimens in an intact state and subsequently repeated following ACL resection. Simulated gait was performed using motor-actuated quadriceps, and loads at the hip and ankle. Specimen-specific FE models of these experiments were developed in both intact and ACL-deficient states. Model simulations compared kinematics and loading of the experimental TF and PF joints, with average RMS differences [max] of 3.0° [8.2°] and 2.1° [8.4°] in rotations, and 1.7 [3.0] and 2.5 [5.1] mm in translations, for intact and ACL-deficient states, respectively. The timing of peak quadriceps force during stance and swing phase of gait was accurately replicated within 2° of knee flexion and with an average error of 16.7% across specimens and pathology. Ligament recruitment patterns were unique in each specimen; recruitment variability was likely influenced by variations in ligament attachment locations. ACL resections demonstrated contrasting joint mechanics in the two specimens with altered knee motion shown in one specimen (up to 5 mm anterior tibial translation) while increased TF joint loading was shown in the other (up to 400 N).  相似文献   

15.
Three adult squirrel monkeys were trained to run on a motor-driven treadmill that was inclined downwardly and upwardly at 8°, 16° and 28°, and horizontally (0°). Films were used to compare the gait and kinematics of the animals across the inclines. All three animals used both lateral and diagonal sequence gaits, although the former was preferred at all but the upward 16° and 28° inclines. Cycle duration and hind limb stance and swing durations tended to increase as downward inclination decreased. Trunk inclination, except at 28° downward, tended to parallel the changes in treadmill inclination. The most dramatic and consistent change for the hind limb joint displacement patterns was that maximum extension during stance increased as the treadmill inclination increased from 28° downward to 28° upward. In contrast to an earlier study by Prost & Sussman (1969), we could find no evidence that squirrel monkeys are best adapted to run on upward inclines of about 16°. The utilization of diagonal sequence gaits on the upward inclines supports previous suggestions that the preference for these gaits in primates is associated with an evolutionary increase in climbing behaviors.  相似文献   

16.
Knee instability is a major problem in patients with anterior cruciate ligament injury or knee osteoarthritis. A valid and clinically meaningful measure for functional knee instability is lacking. The concept of the gait sensitivity norm, the normalized perturbation response of a walking system to external perturbations, could be a sensible way to quantify knee instability. The aim of this study is to explore the feasibility of this concept for measurement of knee responses, using controlled external perturbations during walking in healthy subjects.Nine young healthy participants walked on a treadmill, while three dimensional kinematics were measured. Sudden lateral translations of the treadmill were applied at five different intensities during stance. Right knee kinematic responses and spatio-temporal parameters were tracked for the perturbed stride and following four cycles, to calculate perturbation response and gait sensitivity norm values (i.e. response/perturbation) in various ways.The perturbation response values in terms of knee flexion and abduction increased with perturbation intensity and decreased with an increased number of steps after perturbation. For flexion and ab/adduction during midswing, the gait sensitivity norm values were shown to be constant over perturbation intensities, demonstrating the potential of the gait sensitivity norm as a robust measure of knee responses to perturbations.These results show the feasibility of using the gait sensitivity norm concept for certain gait indicators based on kinematics of the knee, as a measure of responses during perturbed gait. The current findings in healthy subjects could serve as reference-data to quantify pathological knee instability.  相似文献   

17.
Knowledge of accurate in-vivo 6 degree-of-freedom (6-DOF) kinematics of total hip arthroplasty (THA) during daily activities is critical for improvement of longevity of the components. Previous studies assessed in-vivo THA kinematics using skin marker-based motion analysis. However, skin markers are prone to move with respect to the underlying bones. A non-invasive dual fluoroscopic imaging system (DFIS) based tracking technique has been used to avoid skin artifacts and provide accurate 6-DOF kinematic measurement. This study aimed to quantify in-vivo 6-DOF THA kinematics during gait using DFIS. Twenty eight well-functioning THAs were evaluated during treadmill gait under DFIS surveillance. The maximum translations of the femoral head were 0.46±0.10 mm and 0.45±0.10 mm during the stance and swing phases (p=0.57), respectively. The range of hip flexion was from 8.7° to 47.6°, adduction from 3.0° to 12.5° and external rotation from 19.2° to 29.7°. The THA was flexed, externally rotated and adducted throughout the gait. The magnitudes of the femoral head translations were found to be within the manufacture tolerance of the components, suggesting that in-vivo hip “pistoning” during gait cycle may be minimal in well-functioning THAs. The 6-DOF kinematics could be used as the baseline knowledge for further improvement of wear-testing of hip implant, implants manufacturing and implant positioning during surgery.  相似文献   

18.
Many children with cerebral palsy walk in a crouch gait that progressively worsens over time, decreasing walking efficiency and leading to joint degeneration. This study examined the effect of crouched postures on the capacity of muscles to extend the hip and knee joints and the joint flexions induced by gravity during the single-limb stance phase of gait. We first characterized representative mild, moderate, and severe crouch gait kinematics based on a large group of subjects with cerebral palsy (N=316). We then used a three-dimensional model of the musculoskeletal system and its associated equations of motion to determine the effect of these crouched gait postures on (1) the capacity of individual muscles to extend the hip and knee joints, which we defined as the angular accelerations of the joints, towards extension, that resulted from applying a 1N muscle force to the model, and (2) the angular acceleration of the joints induced by gravity. Our analysis showed that the capacities of almost all the major hip and knee extensors were markedly reduced in a crouched gait posture, with the exception of the hamstrings muscle group, whose extension capacity was maintained in a crouched posture. Crouch gait also increased the flexion accelerations induced by gravity at the hip and knee throughout single-limb stance. These findings help explain the increased energy requirements and progressive nature of crouch gait in patients with cerebral palsy.  相似文献   

19.
The recent development of a soft tissue artifact (STA) suppression method allows us to re-evaluate the tibiofemoral kinematics currently linked to non-contact knee injuries. The purpose of this study was therefore to evaluate knee joint kinematics and kinetics in six degrees of freedom (DoF) during the loading phases of a jump lunge and side cut using this in silico method. Thirty-five healthy adults completed these movements and their surface marker trajectories were then scaled and processed with OpenSim’s inverse kinematics (IK) and inverse dynamics tools. Knee flexion angle-dependent kinematic constraints defined based on previous bone pin (BP) marker trajectories were then applied to the OpenSim model during IK and these constrained results were then processed with the standard inverse dynamics tool. Significant differences for all hip, knee, and ankle DoF were observed after STA suppression for both the jump lunge and side cut. Using clinically relevant effect size estimates, we conclude that STA contamination had led to misclassifications in hip transverse plane angles, knee frontal and transverse plane angles, medial/lateral and distractive/compressive knee translations, and knee frontal plane moments between the NoBP and the BP IK solutions. Our results have substantial clinical implications since past research has used joint kinematics and kinetics contaminated by STA to identify risk factors for musculoskeletal injuries.  相似文献   

20.
This study aimed to identify adaptive changes in running kinematics and impact shock transmission as a function of head stability requirements. Fifteen strides from twelve recreational runners were collected during preferred speed treadmill running. Head stability demands were manipulated through real-time visual feedback that required head-gaze orientation to maintain within boxes of different sizes, ranging from 21° to 3° of visual angle with 3° decrements. The main outcome measures were tibial and head peak accelerations in the time and frequency domains (impact and active phases), shock transmission from tibia to head, stride parameters, and sagittal plane joint kinematics. Increasing head stability requirements resulted in decreases in the amplitude and integrated power of head acceleration during the active phase of stance. During the impact portion of stance tibial and head acceleration and shock transmission remained similar across visual conditions. In response to increased head stability requirements, participants increased stride frequency approximately 8% above preferred, as well as hip flexion angle at impact; stance time and knee and ankle joint angles at impact did not change. Changes in lower limb joint configurations (smaller hip extension and ankle plantar-flexion and greater knee flexion) occurred at toe-off and likely contributed to reducing the vertical displacement of the center of mass with increased head stability demands. These adaptive changes in the lower limb enabled runners to increase the time that voluntary control is allowed without embedding additional impact loadings, and therefore active control of the head orientation was facilitated in response to different visual task constraints.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号