首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
  1. Optimal spatiotemporal filters for early vision were computed as a function of signal-to-noise ratio (SNR) and α, a parameter defined as the ratio of the width of the probability distribution of velocities as perceived by the naturally behaving animal, and the characteristic velocity of the photoreceptors (the velocity required to move across a receptor's receptive field in a receptor's integration time). Animals that move slowly, on average, compared with the characteristic velocity of their photoreceptors have α ? 1, animals that move fast have α ? 1.
  2. For α ? 1, the temporal part of the optimal filter adapts more to different SNRs (light levels) than the spatial part, leading to large adjustments in temporal resolving power and strong self-inhibition at high SNR, but little lateral inhibition.
  3. For α ? 1, the spatial part of the filter adapts more strongly than the temporal part, leading to strong lateral inhibition at high SNR, and little self-inhibition.
  4. For α ≈ 1, both spatial and temporal properties change about equally much when varying SNR.
  5. Varying the width of the angular sensitivity of the photoreceptors shows that for every combination of α and SNR there is an optimal width. Visual systems with large α need wider angular sensitivities, in particular at low SNR, in order to reach the information maximum than visual systems with small α.
  相似文献   

2.

Objective

To determine the vision-related quality of life (VR-QOL) after surgery for macula-off rhegmatogenous retinal detachment (RRD) in relation to visual acuity, contrast acuity, and color vision.

Methods

In a prospective observational study, we included 55 patients with a macula-off RRD. Best corrected visual acuity (BCVA), color vision (saturated and desaturated color confusion indices (CCI)) and contrast acuity were measured at 12 months postoperatively in both the RRD eye and the fellow control eye, and the 25-item National Eye Institute Visual Function Questionnaire (NEI VFQ-25) was filled out.

Results

Operated and fellow control eyes differed significantly in mean LogMAR BCVA (P<0.0001), median Log contrast acuity (P<0.0001), saturated CCI (P = 0.009), and desaturated CCI (P = 0.016). Significant correlations were observed between the NEI VFQ-25 overall composite score and postoperative LogMAR BCVA (R = −0.551, P<0.0001), contrast acuity (R = 0.472, P<0.0001), saturated CCI (R = −0.315, P = 0.023), and desaturated CCI (R = −0.283, P = 0.044).

Conclusions

A lower VR-QOL was highly correlated to a worse postoperative BCVA and contrast acuity and to a lesser extent to color vision disturbances.  相似文献   

3.

Purpose

To evaluate postoperative metamorphopsia in macula-off rhegmatogenous retinal detachment (RRD) and its association with visual function, vision related quality of life, and optical coherence tomography (OCT) findings.

Methods

45 patients with primary macula-off RRD were included. At 12 months postoperatively, data on metamorphopsia using sine amsler charts (SAC), best corrected visual acuity (BCVA), letter contrast sensitivity, color vision (saturated and desaturated color confusion indexes), critical print size, reading acuity, the 25-item National Eye Institute Visual Functioning Questionnaire (NEI-VFQ-25), and OCT, were obtained.

Results

Metamorphopsia was present in 39 patients (88.6%), with most of them (n = 35, 77.8%) showing only mild metamorphopsia (SAC score = 1). Patients with metamorphopsia had significantly worse postoperative BCVA (p = 0.02), critical print size (p<0.0005), and reading acuity (p = 0.001) compared to patients without metamorphopsia. Other visual function outcomes and NEI-VFQ-25 overall composite score were all also somewhat lower in patients with metamorphopsia, but this did not reach statistical significance. No association with OCT findings was present.

Conclusion

The prevalence of postoperative metamorphopsia in macula-off RRD patients is high, however, the degree of metamorphopsia is relatively low. When metamorphopsia is present, visual functions seem to be compromised, while vision related quality of life is only mildly affected.  相似文献   

4.
Visually evoked potentials were used to determine the spatial contrast response function of the visual system and the visual acuity of the pigeon. The spatial contrast response describes the relationship between the contrast in a pattern of vertical stripes, whose luminance is a function of position, and the amplitude of the visually evoked response at various spatial frequencies for a given temporal frequency (pattern reversal frequency); it indicates how particular spatial frequencies are attenuated in the visual system. The visually evoked responses were recorded using monopolar stainless steel electrodes inserted into the stratum griseum superficiale of the optic tectum; the depth of penetration was determined on the basis of a stereotactic atlas. The stimulus patterns were generated on a video monitor placed 75 cm in front of the animal's eye perpendicular to the optic axis. The spatial contrast response function measured at 10% contrast and 0.5 Hz reversal frequency shows a peak at a spatial frequency of 0.5 c/deg, corresponding to 1 degree of visual angle, and decreases progressively at higher spatial frequencies. The high-frequency limit (cut-off frequency) for resolution of sinusoidal gratings, estimated from the contrast response function, is 15.5 c/deg, corresponding to a visual acuity of 1.9 min of arc.  相似文献   

5.
The visual sensitivity of tree squirrels from three different species (two western gray squirrels, Sciurus griseus; three fox squirrels, Sciurus niger; and an eastern gray squirrel, Sciurus carolinensis) was measured for spatial patterns defined by luminance differences. Spatial contrast sensitivity functions were determined in behavioral discrimination experiments in which the stimuli were sinusoidally-modulated gratings. At an average luminance level of 3.4 cd/m2 these squirrels were maximally sensitive to spatial frequencies of about 0.5 cycles/degree (c/d). These experiments, in conjunction with additional measurements involving discrimination of square-wave grating patterns, also indicate that the finest gratings these squirrels can discriminate average 2.2 c/d (SD = 0.42 c/d). There are no obvious differences in resolution acuity among the three species. Grating acuity also was measured at a much higher luminance level (340 cd/m2). The results of this experiment indicate that the spatial acuity of the tree squirrel increases with luminance level, reaching a maximum of 3.9 c/d at 340 cd/m2.  相似文献   

6.

Background

In a subpopulation of patients with essential hypertension, therapeutic targets are not met, despite the use of multiple types of medication. In this paper we describe our first experience with a novel percutaneous treatment modality using renal artery radiofrequency (RF) ablation.

Methods

Patients who were resistant to at least three types of antihypertensive medical therapy (office systolic blood pressure?≥?160 mmHg; n?=?9) or who did not tolerate medication (n?=?2) were selected. Between July and November 2010, a total of 11 patients received percutaneous RF treatment. Patients were followed up for 1 month after treatment. Urine and blood samples were taken to evaluate the effects on renal function and neurohumeral factors.

Results

No periprocedural complications or adverse events during follow-up were noted. A reduction of mean office blood pressure was seen from 203/109?±?32/19 mmHg at baseline to 178/97?±?28/21 mmHg at 1 month follow-up (mean difference 25?±?12 mmHg, p?<?0.01). Also, we noted a significant decrease in aldosterone level (391?±?210 pmol/L versus 250?±?142 pmol/L; p?=?0.03), while there was no decrease in plasma renin activity (190?±?134 fmol/L/s versus 195?±?163 fmol/L/s; p?=?0.43). No change in renal function was noted.

Conclusion

Catheter-based renal denervation seems an attractive novel minimally invasive treatment option in patients with resistant hypertension, with a low risk of serious adverse events.  相似文献   

7.

Objective

Closure of atrial septal defects (ASD) prevents pulmonary hypertension, right heart failure and thromboembolic stroke. The exact timing for ASD closure is controversial.

Methods

In a prospective study to address the question whether unapparent pulmonary hypertension can be revealed prior to right ventricular (RV) remodelling, patients were investigated before and 6, 12, and 24 months after ASD closure using exercise stress echocardiography (ESE) and ergospirometry (n?=?24).

Results

At rest, RV systolic pressure (RVSP) was normal in 58.8 %, slightly elevated in 26.5 %, and moderately elevated in 11.8 %. One patient showed severe pulmonary hypertension. During ESE, all patients with normal RVSP at rest exhibited an increase (25.7?±?1.2 mmHg vs. 45.3?±?2.3 mmHg, p?<?0.001). After closure the RVSP was lower, both at rest and ESE. RV diameters decreased too. Tricuspid annulus plane systolic excursion (TAPSE) at rest remained lower after closure (24.0?±?0.9 vs. 22.0?±?0.9 mm, p?<?0.05). TAPSE in ESE was elevated, and stayed stable after closure (30.1?±?1.8 mm vs. 29.3?±?1.6 mm). Before closure, RV systolic tissue velocities (sa) at rest were normal and decreased after closure (14.0?±?1.0 cm/s vs. 11.5?±?0.7 (6 month) vs. 10.6?±?0.5 cm/s (12 month), p?<?0.05). During ESE, sa velocity was similar before and after closure (23.0?±?1.3 cm/s vs. 23.3?±?1.9 cm/s). Maximal oxygen uptake (VO2/kg) did not differ between baseline and follow-ups.

Conclusion

Latent pulmonary hypertension may become apparent in ESE. ASD closure leads to a significant reduction in this stress-induced pulmonary hypertension and to a decrease in the right heart diameters indicating reverse RV remodelling. RV functional parameters at rest did not improve. The VO2/kg did not change after ASD closure.  相似文献   

8.

Background

Myocardial contrast echocardiography and coronary flow velocity pattern with a rapid diastolic deceleration time after percutaneous coronary intervention has been reported to be useful in assessing microvascular damage in patients with acute myocardial infarction.

Aim

To evaluate myocardial contrast echocardiography with harmonic power Doppler imaging, coronary flow velocity reserve and coronary artery flow pattern in predicting functional recovery by using transthoracic echocardiography.

Methods

Thirty patients with anterior acute myocardial infarction underwent myocardial contrast echocardiography at rest and during hyperemia and were quantitatively analyzed by the peak color pixel intensity ratio of the risk area to the control area (PIR). Coronary flow pattern was measured using transthoracic echocardiography in the distal portion of left anterior descending artery within 24 hours after recanalization and we assessed deceleration time of diastolic flow velocity. Coronary flow velocity reserve was calculated two weeks after acute myocardial infarction. Left ventricular end-diastolic volumes and ejection fraction by angiography were computed.

Results

Pts were divided into 2 groups according to the deceleration time of coronary artery flow pattern (Group A; 20 pts with deceleration time ≧ 600 msec, Group B; 10 pts with deceleration time < 600 msec). In acute phase, there were no significant differences in left ventricular end-diastolic volume and ejection fraction (Left ventricular end-diastolic volume 112 ± 33 vs. 146 ± 38 ml, ejection fraction 50 ± 7 vs. 45 ± 9 %; group A vs. B). However, left ventricular end-diastolic volume in Group B was significantly larger than that in Group A (192 ± 39 vs. 114 ± 30 ml, p < 0.01), and ejection fraction in Group B was significantly lower than that in Group A (39 ± 9 vs. 52 ± 7%, p < 0.01) at 6 months. PIR and coronary flow velocity reserve of Group A were higher than Group B (PIR, at rest: 0.668 ± 0.178 vs. 0.248 ± 0.015, p < 0.0001: during hyperemia 0.725 ± 0.194 vs. 0.295 ± 0.107, p < 0.0001; coronary flow velocity reserve, 2.60 ± 0.80 vs. 1.31 ± 0.29, p = 0.0002, respectively).

Conclusion

The preserved microvasculature detecting by myocardial contrast echocardiography and coronary flow velocity reserve is related to functional recovery after acute myocardial infarction.  相似文献   

9.

Background

Coronary microvascular resistance is increased after primary percutaneous coronary intervention (PCI) for ST-elevation myocardial infarction (STEMI), which may be related in part to changed left ventricular (LV) dynamics. Therefore we studied the coronary microcirculation in relation to systolic and diastolic LV function after STEMI.

Methods

The study cohort consisted of 12 consecutive patients, all treated with primary PCI for a first anterior wall STEMI. At 4 months, we assessed pressure-volume loops. Subsequently, we measured intracoronary pressure and flow velocity and calculated coronary microvascular resistance. Infarct size and LV mass were assessed using magnetic resonance imaging.

Results

Patients with an impaired systolic LV function due to a larger myocardial infarction showed a higher baseline average peak flow velocity (APV) than the other patients (26?±?7 versus 17?±?5 cm/s, p?=?0.003, respectively), and showed an impaired variable microvascular resistance index (2.1?±?1.0 versus 4.1?±?1.3 mmHg?cm?1?s?1, p?=?0.003, respectively). Impaired diastolic relaxation time was inversely correlated with hyperaemic APV (r?=??0.56, p?=?0.003) and positively correlated with hyperaemic microvascular resistance (r?=?0.48, p?=?0.01). LV dilatation was associated with a reduced variable microvascular resistance index (r?=?0.78, p?=?0.006).

Conclusion

A larger anterior myocardial infarction results in impaired LV performance associated with reduced coronary microvascular resistance variability, in particular due to higher coronary blood flow at baseline in these compromised left ventricles.  相似文献   

10.

Background

Non-enzymatic glycation increases hemoglobin-oxygen affinity and reduces oxygen delivery to tissues by altering the structure and function of hemoglobin.

Objectives

We investigated whether an elevated blood concentration of glycosylated hemoglobin (HbA1c) could induce falsely high pulse oximeter oxygen saturation (SpO2) in type 2 diabetic patients during mechanical ventilation or oxygen therapy.

Methods

Arterial oxygen saturation (SaO2) and partial pressure of oxygen (PO2) were determined with simultaneous monitoring of SpO2 in 261 type 2 diabetic patients during ventilation or oxygen inhalation.

Results

Blood concentration of HbA1c was >7% in 114 patients and????7% in 147 patients. Both SaO2 (96.2?±?2.9%, 95% confidence interval [CI] 95.7-96.7% vs. 95.1?±?2.8%, 95% CI 94.7-95.6%) and SpO2 (98.0?±?2.6%, 95% CI 97.6-98.5% vs. 95.3?±?2.8%, 95% CI 94.9-95.8%) were significantly higher in patients with HbA1c >7% than in those with HbA1c????7% (Data are mean?±?SD, all p?<?0.01), but PO2 did not significantly differ between the two groups. Bland-Altman analysis demonstrated a significant bias between SpO2 and SaO2 (1.83 ±0.55%, 95% CI 1.73% -1.94%) and limits of agreement (0.76% and 2.92%) in patients with HbA1c >7%. The differences between SpO2 and SaO2 correlated closely with blood HbA1c levels (Pearson??s r?=?0.307, p?<?0.01).

Conclusions

Elevated blood HbA1c levels lead to an overestimation of SaO2 by SpO2, suggesting that arterial blood gas analysis may be needed for type 2 diabetic patients with poor glycemic control during the treatment of hypoxemia.  相似文献   

11.

Background

The insertion of Ventricular Assist Devices is a common strategy for cardiovascular support in patients with refractory cardiogenic shock. This study sought to determine the impact of ventricular assist devices on the dynamic relationship between arterial blood pressure and cerebral blood flow velocity.

Methods

A sample of 5 patients supported with a pulsatile ventricular assist device was compared with 5 control patients. Controls were matched for age, co-morbidities, current diagnosis and cardiac output state, to cases. Beat-to-beat recordings of mean arterial pressure and cerebral blood flow velocity, using transcranial Doppler were obtained. Transfer function analysis was performed on the lowpass filtered pressure and flow signals, to assess gain, phase and coherence of the relationship between mean arterial blood pressure and cerebral blood flow velocity. These parameters were derived from the very low frequency (0.02-0.07 Hz), low frequency (0.07-0.2 Hz) and high frequency (0.2-0.35 Hz).

Results

No significant difference was found in gain and phase values between the two groups, but the low frequency coherence was significantly higher in cases compared with controls (mean ± SD: 0.65 ± 0.16 vs 0.38 ± 0.19, P = 0.04). The two cases with highest coherence (~0.8) also had much higher spectral power in mean arterial blood pressure.

Conclusions

Pulsatile ventricular assist devices affect the coherence but not the gain or phase of the cerebral pressure-flow relationship in the low frequency range; thus whether there was any significant disruption of cerebral autoregulation mechanism was not exactly clear. The augmentation of input pressure fluctuations might contribute in part to the higher coherence observed.  相似文献   

12.

Introduction

A case of severe acute bilateral angle closure glaucoma with complete visual loss after oral topiramate therapy.

Case presentation

A 34 year-old woman developed bilateral severe visual loss 2 days after doubling the dosage of topiramate. Her best-corrected visual acuity (BCVA) was counting fingers in both eyes (OU). Intraocular pressures were 49 mm and 51 mm of Hg in right and left eyes respectively, with conjunctival chemosis, corneal edema, shallow anterior chamber and closed angles on gonioscopy. B-scan ultrasound revealed annular peripheral choroidal effusions in both eyes.

Conclusion

Intraocular pressures and anterior chamber depth were normalized after discontinuation of topiramate and initiation of antiglaucoma therapy. Two weeks later, visual acuities improved to 20/25 in the right eye and 20/40 in the left eye. B-scan ultrasound showed resolution of choroidal effusion. Topiramate, an oral sulpha-derivative medication is known to cause ciliochoroidal effusions, which lead to forward rotation of the ciliary body and displacement of the lens-iris diaphragm, with resultant acute angle closure glaucoma and myopic shift.  相似文献   

13.

Background and aims

Crop biofortification programs require fast, accurate and inexpensive methods of identifying nutrient dense genotypes. This study investigated energy-dispersive X-ray fluorescence spectrometry (EDXRF) for the measurement of zinc (Zn), iron (Fe) and selenium (Se) concentrations in whole grain wheat.

Methods

Grain samples were obtained from existing biofortification programs. Reference Zn, Fe and Se concentrations were obtained using inductively coupled plasma optical emission spectrometry (ICP-OES) and/or inductively coupled plasma mass spectrometry (ICP-MS). One set of 25 samples was used to calibrate for Zn (19–60?mg?kg–1) and Fe (26–41?mg?kg–1), with 25 further samples used to calibrate for Se (2–31?mg?kg–1 ). Calibrations were validated using an additional 40–50 wheat samples.

Results

EDXRF limits of quantification (LOQ) were estimated as 7, 3 and 2?mg?kg–1 for Zn, Fe, and Se, respectively. EDXRF results were highly correlated with ICP-OES or -MS values. Standard errors of EDXRF predictions were ±2.2?mg Zn kg–1, ±2.6?mg Fe kg–1, and ±1.5?mg Se kg–1.

Conclusion

EDXRF offers a fast and economical method for the assessment of Zn, Fe and Se concentration in wheat biofortification programs.  相似文献   

14.

Background

To investigate the clinical differences between pulse wave velocity and augmentation index in diabetic retinopathy.

Methods

The subjects were 201 patients with type 2 diabetes. These subjects were measured for both augmentation index (AI) and brachial-ankle pulse wave velocity (baPWV) by a pulse wave analyzer. The relationships between AI, baPWV, and diabetic retinopathy were examined.

Results

BaPWV was significantly higher in patients with diabetic retinopathy than in individuals without the disease. (20.13 ± 3.66 vs.17.14 ± 3.60 m/s p < 0.001) AI was higher in patients with diabetic retinopathy, but not significantly. (19.5 ± 15.2 vs. 14.8 ± 20.5% p = 0.14) The association between baPWV and diabetic retinopathy remained statistically significant after adjustment. (Odds ratio: 1.21 Per m/s, 95% confidence interval: 1.07–1.37) On the other hand, the association between AI and diabetic retinopathy was not statistically significant. (Odds ratio: 1.01 Per %, 95% confidence interval: 0.98–1.03)

Conclusion

BaPWV is associated with diabetic retinopathy, but AI is not. The clinical significance appears to be different between PWV and AI in patients with diabetes.  相似文献   

15.
Compensatory optomotor reflexes were examined in crayfish (Procambarus clarkii) with oscillating sine wave gratings and step displacements of a single stripe. A capacitance transducer was used to measure the rotation of the eyestalk about its longitudinal axis. System studies reveal a spatial frequency response independent of velocity and stimulus amplitude and linear contrast sensitivity similar to that of neurons in the visual pathway. The reflex operates at low temporal frequencies (<0.002 Hz to 0.5 Hz) and exhibits a low-pass temporal frequency response with cut-off frequency of 0.1 Hz. Eyestalk rotation increases as a saturable function of the angular stimulus displacement. When compared to the oscillatory response, transient responses are faster, and they exhibit a lower gain for large stimulus displacements. These differences may reflect system nonlinearity and/or the presence of at least two classes of afferents in the visual pathway. Our metric for information transmission is the Kullback-Leibler (K-L) distance, which is inversely proportional to the probability of an error in distinguishing two stimuli. K-L distances are related to differences in responsiveness for variations in spatial frequency, contrast, and angular displacement. The results are interpreted in terms of the neural filters that shape the system response and the constraints that the K-L distances place on information transmission in the afferent visual pathway.  相似文献   

16.
It was previously shown that a small lesion in the primary somatosensory cortex (S1) prevented both cortical plasticity and sensory learning in the adult mouse visual system: While 3-month-old control mice continued to show ocular dominance (OD) plasticity in their primary visual cortex (V1) after monocular deprivation (MD), age-matched mice with a small photothrombotically induced (PT) stroke lesion in S1, positioned at least 1 mm anterior to the anterior border of V1, no longer expressed OD-plasticity. In addition, in the S1-lesioned mice, neither the experience-dependent increase of the spatial frequency threshold (“visual acuity”) nor of the contrast threshold (“contrast sensitivity”) of the optomotor reflex through the open eye was present. To assess whether these plasticity impairments can also occur if a lesion is placed more distant from V1, we tested the effect of a PT-lesion in the secondary motor cortex (M2). We observed that mice with a small M2-lesion restricted to the superficial cortical layers no longer expressed an OD-shift towards the open eye after 7 days of MD in V1 of the lesioned hemisphere. Consistent with previous findings about the consequences of an S1-lesion, OD-plasticity in V1 of the nonlesioned hemisphere of the M2-lesioned mice was still present. In addition, the experience-dependent improvements of both visual acuity and contrast sensitivity of the open eye were severely reduced. In contrast, sham-lesioned mice displayed both an OD-shift and improvements of visual capabilities of their open eye. To summarize, our data indicate that even a very small lesion restricted to the superficial cortical layers and more than 3mm anterior to the anterior border of V1 compromised V1-plasticity and impaired learning-induced visual improvements in adult mice. Thus both plasticity phenomena cannot only depend on modality-specific and local nerve cell networks but are clearly influenced by long-range interactions even from distant brain regions.  相似文献   

17.

Background

Implications of donor milk feedings on infant growth in resource limited settings remain uncertain. This knowledge gap includes the impact of donor milk availability on infant intake of mother’s own milk. Therefore, this investigation aimed to measure intake and growth in infants receiving donor milk when born to women from resource limited backgrounds with high rates of human immunodeficiency virus (HIV).

Methods

A retrospective cohort study enrolled eligible infants admitted to a South African combined neonatal intensive and secondary high care unit, within a one year admission period during 2015, with signed consent for donor milk feedings. A certified milk bank provided donor milk. Daily nutritional intake during the first month was recorded. Details included proportional intake of donor milk, mother’s own milk and infant formula. The primary outcome of infant growth velocity from day back to birth weight to discharge was calculated when length of stay was ≥14 days. Analyses primarily used T-tests; mixed effects models compared weekly calorie intake.

Results

One hundred five infants with donor milk consent were born at 30.9?±?3.6 weeks of gestation, weighing 1389?±?708 g. Forty percent of mothers had HIV. Infant growth velocity did not differ based on percent of feedings as donor milk (≥ 50%: 11.8?±?4.9 g/kg/d; <?50%: 13.5?±?5.3 g/kg/d; p?=?0.3). Percent of feedings from donor milk was similar based on maternal HIV status (positive: 31?±?25%; negative: 36?±?29%; p?=?0.4), as was percent of feedings as mother’s milk (positive: 53?±?35%; negative: 58?±?30%; p?=?0.4). Calorie intake increased markedly during the first two weeks and then plateaued (p?<?0.0001).

Conclusions

Donor milk feedings in higher proportions did not further impair growth of infants managed in a South African combined neonatal intensive and secondary high care unit with growth rates already below reference ranges. The provision of donor milk contributed to feedings being composed of primarily human milk during the first month. Increasing early calorie intake may improve infant growth in this center.
  相似文献   

18.

Background

The retinal vasculature is a capillary network of blood vessels that nourishes the inner retina of most mammals. Developmental abnormalities or microvascular complications in the retinal vasculature result in severe human eye diseases that lead to blindness. To exploit the advantages of zebrafish for genetic, developmental and pharmacological studies of retinal vasculature, we characterised the intraocular vasculature in zebrafish.

Results

We show a detailed morphological and developmental analysis of the retinal blood supply in zebrafish. Similar to the transient hyaloid vasculature in mammalian embryos, vessels are first found attached to the zebrafish lens at 2.5 days post fertilisation. These vessels progressively lose contact with the lens and by 30 days post fertilisation adhere to the inner limiting membrane of the juvenile retina. Ultrastructure analysis shows these vessels to exhibit distinctive hallmarks of mammalian retinal vasculature. For example, smooth muscle actin-expressing pericytes are ensheathed by the basal lamina of the blood vessel, and vesicle vacuolar organelles (VVO), subcellular mediators of vessel-retinal nourishment, are present. Finally, we identify 9 genes with cell membrane, extracellular matrix and unknown identity that are necessary for zebrafish hyaloid and retinal vasculature development.

Conclusion

Zebrafish have a retinal blood supply with a characteristic developmental and adult morphology. Abnormalities of these intraocular vessels are easily observed, enabling application of genetic and chemical approaches in zebrafish to identify molecular regulators of hyaloid and retinal vasculature in development and disease.  相似文献   

19.
Zebrafish are a proven model for vision research, however many of the earlier methods generally focused on larval fish or demonstrated a simple response. More recently adult visual behavior in zebrafish has become of interest, but methods to measure specific responses are new coming. To address this gap, we set out to develop a methodology to repeatedly and accurately utilize the optokinetic response (OKR) to measure visual acuity in adult zebrafish. Here we show that the adult zebrafish''s visual acuity can be measured, including both binocular and monocular acuities. Because the fish is not harmed during the procedure, the visual acuity can be measured and compared over short or long periods of time. The visual acuity measurements described here can also be done quickly allowing for high throughput and for additional visual procedures if desired. This type of analysis is conducive to drug intervention studies or investigations of disease progression.  相似文献   

20.

Background

Recently a new automatic device that measures brachial-ankle pulse wave velocity using an oscillometric method has been developed. However, the practical significance of brachial-ankle pulse wave velocity measurement remains uncertain. The purpose of this study was to examine the association between brachial-ankle pulse wave velocity and symptomatic cerebral infarction in patients with type 2 diabetes.

Methods

One thousand sixty six patients with type 2 diabetes were studied cross-sectionally. Measurements of brachial-ankle pulse wave velocity were made using the automatic device. Logistic regression analysis was used to calculate the odds ratio for cerebral infarction.

Results

The presence of symptomatic cerebral infarction was confirmed in 86 patients. In these patients brachial-ankle pulse wave velocity was found to be significantly higher than in patients without cerebral infarction (18.94 ± 4.95 versus 16.46 ± 3.62 m/s, p < 0.01). The association between brachial-ankle pulse wave velocity and cerebral infarction remained significant after adjustment for traditional risk factors. There was an increasing odds ratio for each tertile of brachial-ankle pulse wave velocity, from the second tertile (odds ratio, 2.28; 95% confidence interval, 1.05 to 4.94), to the third (odds ratio, 2.53; 95% confidence interval, 1.09 to 5.86).

Conclusion

Overall, we conclude that an increase in brachial-ankle pulse wave velocity is associated with symptomatic cerebral infarction in patients with type 2 diabetes.  相似文献   