首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Capillary electrophoresis with collinear laser-induced fluorescence detection was used for the analysis of steroids in single R2C cells. Progesterone secretion was monitored from cultured cells and subsequently detected in single cells. Mass detection limit of 10(-18) mol for dansylated steroids was achieved with the 325-nm line of a helium-cadmium laser. Dansylhydrazine proved to be an effective fluorescent tag for derivatization of steroids outside and inside the biological cell. Fluorescence microscopy indicates that a dimethyl sulfoxide-containing physiological buffer was sufficient to incorporate the tag inside the cell for subsequent steroid derivatization.  相似文献   

2.
A new analytical method for vigabatrin based on capillary electrophoretic separation and laser-induced fluorescence detection has been developed. 5-Carboxytetramethylrhodamine succinimidyl ester was used for precolumn derivatization of the non-fluorescent drug. Optimal separation and detection were obtained with an electrophoretic buffer of 50 mM sodium borate (pH9.5) containing 10 mM sodium dodecyl sulfate and a green He-Ne laser (excitation at 543.5 nm, emission at 589 nm). The concentration limit of detection in aqueous solution was 24 nM. Combined with a simple cleanup procedure, this method can be applied to the determination of vigabatrin in human plasma. A calibration curve ranging from 1.5 to 200 microM shown to be linear. Both the within-day and day-to-day reproducibilities and accuracies were less then 14.3% and 4.9% respectively. The limit of detection of vigabatrin in plasma was about 0.13 microM  相似文献   

3.
Development of a method for the determination of insulin based on capillary electrophoresis with laser-induced native fluorescence detection is described. Under optimal conditions, insulin as low as 73 amol can be detected with a good signal-to-noise ratio (S/N=10 peak-to-peak). Application of this method for the determination of insulin content in single cells from the insulin-secreting cell lines RINm5F and βTC3 is demonstrated. Non-bonded poly(ethylene oxide)-coated and bare capillaries are evaluated for this purpose, with the latter found to be more suitable for single-cell analysis.  相似文献   

4.
Capillary electrophoresis (CE) with HeCd laser-induced fluorescence (LIF) detection and its application in forensic toxicology is demonstrated by the determination of

-lysergic acid diethylamide (LSD) in blood. Following precipitation of proteins, washing of the evaporated supernatant and extraction, the residue was reconstituted in methanol and injected electrokinetically (10 s, 10 kV). The total analysis time for quantification of LSD was 8 min using a citrate–methanol buffer, pH 4.0. With this buffer system it is possible to separate LSD, nor-LSD, iso-LSD and iso-nor-LSD. Using a specific sample preparation, electrokinetic injection, extended light path (bubble cell) capillaries and especially LIF detection (λex 325 nm, λem 435 nm), a limit of detection of 0.1–0.2 ng LSD per ml blood could be obtained. The limit of quantitation was about 0.4–0.5 ng/ml. The quantitative evaluation for LSD was carried out using methylergometrine as internal standard. The precision expressed as coefficient of variation (C.V.) and accuracy of the method were <20% and 86–110%, respectively. The application of the method to human blood samples from two forensic cases and a comparison with radioimmunoassay demonstrated that the results were consistent.  相似文献   

5.
A capillary electrophoresis method for the simultaneous separation and enantioseparation of the antibacterial drug ofloxacin and its metabolites desmethyl ofloxacin and ofloxacin N-oxide in human urine has been developed and validated. Enantioseparation was achieved by adding sulfobutyl β-cyclodextrin to the running buffer. The detection of the analytes was performed by laser-induced fluorescence (LIF) detection using a HeCd-laser with an excitation wavelength of 325 nm. In comparison with conventional UV detection, LIF detection provides higher sensitivity and selectivity. The separation can be performed after direct injection of urine into the capillary without any sample preparation, because no matrix compounds interfere with the assay. Additionally, the high sensitivity of this method allows the quantification of the very low concentrations of enantiomers of both metabolites. The limit of quantification was 250 ng/ml for ofloxacin enantiomers and 100 ng/ml for each metabolites’ enantiomers. This method was applied to the analysis of human urine samples collected from a volunteer after oral administration of 200 mg of (±)-ofloxacin to elucidate stereoselective differences in the formation and excretion of the metabolites. It could be demonstrated that the renal excretion of the S-configured metabolites, especially S-desmethyl ofloxacin, within the first 20 h after dosage, is significantly lower than that of the R-enantiomers.  相似文献   

6.
A method based on capillary electrophoresis has been developed for the analysis of the novel antidepressant drug duloxetine in human plasma. The method makes use of laser-induced fluorescence detection after derivatisation of the analyte with 5-(4,6-dichlorotriazinyl)aminofluorescein at pH 11. A single step liquid/liquid extraction procedure with a mixture of hexane/2-propanol allows the sample clean-up with extraction yields always ≥84% and interference removal. The electrophoretic separation is achieved using uncoated fused silica capillaries (60.0 cm effective length, 75.0 cm total length, 50 μm internal diameter) and a background electrolyte composed of borate buffer (40 mM, pH 10.3), tetrabutylammonium bromide (10 mM), and acetone (10%, v/v). The applied voltage is 20 kV; the samples are injected by pressure (50 mbar × 8 s). The method has been fully validated in terms of linearity range (2.5–150 ng mL?1), LOD and LOQ (1.0 and 2.5 ng mL?1, respectively), precision (R.S.D. < 6.7%) and accuracy (recovery >78%). Application to samples obtained from patients under treatment with duloxetine gave good results. The method represents the first application of capillary electrophoresis to the analysis of duloxetine in human plasma.  相似文献   

7.
Damage to cellular DNA is implicated in the early stages of carcinogenesis and in the cytotoxicity of many anticancer agents, including ionizing radiation. Sensitive techniques are required for measuring cellular levels of DNA damage. We describe in detail a novel immunoassay that makes use of the resolving power of capillary electrophoresis and the sensitivity of laser-induced fluorescence detection. An example is given of the detection of thymine glycol in DNA produced by irradiation of human cells with a clinical dose of 2 Gy. A detection limit of approximately 10(-21) mol allowed us to monitor the repair of the lesion and to suggest that the cellular repair response may be inducible.  相似文献   

8.
Interest in the use of capillary electrophoresis (CE) as a tool for protein separations continues to grow. Additionally, laser-induced fluorescence (LIF) detection schemes promise ultrasensitive detection of small quantities of these important biomolecules following their separation. In most cases, LIF detection of proteins necessitates their prior derivatization with a fluorescent label molecule. To minimize the amount of additional sample handling and time associated with such labeling procedures, not to mention the sometimes-stringent pH and temperature controls they require, noncovalent labeling is presented as a viable alternative. This review article considers established methods for noncovalent labeling of proteins for their subsequent analysis by CE-LIF. Label molecules suitable for excitation and emission in the ultraviolet, visible, and near-infrared regions of the spectrum are enumerated for a variety of protein analytes.  相似文献   

9.
A newly developed capillary electrophoretic method using laser-induced fluorescence detection (CE-LIF) for the analysis of monosaccharides released from acid hydrolysis of glycosaminoglycans was studied. The method was compared with a previously published method using indirect LIF detection (CE-ILIF). For the CE-LIF method, electrophoretic conditions for the separation of the monosaccharides derivatised with 8-aminopyrene-1,3,6-trisulfonate (APTS) were optimised. The best separations were obtained using 100 mM acetate at pH 4.5 as running buffer. The influence of the injection vial volume on the precision and stability of the sample in different conditions was studied. The detection limits of the CE-LIF method were found to be 0.4-0.6 nM, while those obtained by CE-ILIF ranged from 11.4 to 14.3 microM. Other quality parameters of the method, such as run-to-run precision, day-to-day precision, and linearity were also determined. Finally, the new method was applied to the analysis of the acid hydrolysis products from a glucosaminoglycan (heparin) and a galactosaminoglycan (dermatan sulfate) and cross-contamination between the two solutions was determined. The high sensitivity of the new method allows the determination of dermatan sulfate contaminations in a heparin raw sample down to 0.04% (w/w) and broadens the practical applicability of CE-LIF for the quantitation of the endogenous levels of glycosaminoglycans in animal samples and for pharmacokinetic control after therapeutical heparin administration.  相似文献   

10.
A quantitative and highly sensitive method for the analysis of glycosaminoglycan (GAG)-derived disaccharides that relies on capillary electrophoresis (CE) with laser-induced fluorescence detection is presented. This method enables complete separation of 17 GAG-derived disaccharides in a single run. Unsaturated disaccharides were derivatized with 2-aminoacridone to improve sensitivity. The limit of detection was at the attomole level and approximately 100-fold more sensitive than traditional CE-ultraviolet detection. A CE separation timetable was developed to achieve complete resolution and shorten analysis time. The relative standard deviations of migration time and peak areas at both low and high concentrations of unsaturated disaccharides are all less than 2.7 and 3.2%, respectively, demonstrating that this is a reproducible method. This analysis was successfully applied to cultured Chinese hamster ovary cell samples for determination of GAG disaccharides. The current method simplifies GAG extraction steps and reduces inaccuracy in calculating ratios of heparin/heparan sulfate to chondroitin sulfate/dermatan sulfate resulting from the separate analyses of a single sample.  相似文献   

11.
DNA amplification technology has been applied to clinical diagnosis of infectious disease, genetic disorder, and cancer. After in vitro amplification of a particular DNA region, the methods of analysis for these amplified samples play a pivotal role in clinical diagnosis. Conventional gel electrophoresis has been routinely used in the lab for checking DNA. The whole procedure is time consuming and requires more than 1 ng of DNA for detection. To achieve greater performance in DNA diagnosis, we demonstrated capillary electrophoresis with laser induced fluorescence detection for analysis of amplified DNA. The analysis of DNA could be completed within 3 min and the data is directly entered into the computer. Considering the automatic and rapid process, we believe that this method could be routinely utilized for the clinical diagnosis of amplified DNA products.  相似文献   

12.
A method has been developed by which enzymatically incorporated fluorophore-labeled nucleotide sites in nucleic acid can be quantitated by degradation of nanogram quantities of DNA followed by capillary gel electrophoretic analysis with fluorescence detection. In this way the differing relative labeling densities achieved using either C5-substituted dUTP's or N4-substituted dCTP's were determined. The method has proven to be very useful in obtaining quantitative analytical data from the small quantities of complex molecules produced in nick translations. Various polymerization conditions using DNA polymerase I were examined to determine optimal labeling density. Simultaneous copolymerization of green fluorescing dCTP and dUTP nucleotides were undertaken in an attempt to maximize labeling density.  相似文献   

13.
Capillary electrophoresis (CE) with UV laser-induced native fluorescence detection was developed as a sensitive and selective assay for the direct determination of tramadol in human urine without extraction or preconcentration. The main problem in CE is the small inner diameter of the capillary which causes a low sensitivity with instruments equipped with a UV detector. Laser-induced native fluorescence with a frequency doubled argon ion laser at an excitation wavelength of 257 nm was used for the direct assay of tramadol in urine to enhance the limit of detection about 1000-fold compared to UV absorption detection. The detection system consists of an imaging spectrograph and an intensified CCD camera, which views an illuminated 1.5 mm section of the capillary. This set-up is able to record the whole emission spectra of the analytes to achieve additionally wavelength-resolved electropherograms. In the concentration range of 20 ng/ml–5 μg/ml in human urine coefficients of correlation were better than 0.998. Within-day variation determined on four different concentrations showed accuracies ranging from 90.2 to 108.4%. The relative standard deviation (RSD) was determined to be less than 10%. Day-to-day variation presented accuracies ranging from 90.9 to 103.1% with an RSD less than 8%.  相似文献   

14.
A method for the detection of substance P and its metabolites using capillary electrophoresis with post-capillary derivatization and laser-induced fluorescence detection is described. The post-capillary chemical derivatization system employs naphthalene-2,3-dicarboxaldehyde and β-mercaptoethanol. Two reactor designs were evaluated for the determination of substance P and its metabolites. The fluorescent spectroscopic properties of the derivatives under optimal separation conditions were also examined. The final system was evaluated for the investigation of substance P metabolism in brain following perfusion of the striatum with substance P using microdialysis sampling.  相似文献   

15.
Quantification of aspartic acid enantiomers in rat brain by using a chiral capillary electrophoresis procedure is described. Amino acids were pre-column derivatized with naphthalene-2,3-dialdehyde. Enantiomeric separation was achieved by micellar electrokinetic chromatography in the presence of methanol and β-cyclodextrin as chiral selector. The chiral separation was coupled with laser-induced fluorescence detection. Contents of d- and l-aspartic acids in rats at different stages of growth (from 1 day before birth to 90 days after birth) were determined. d-Aspartic acid was detected in all the brain tissue samples tested, but at different levels. In the cerebrum of rats 1 day before birth, d-aspartic acid was found to be at the highest concentration of 81 nmol/g wet tissue. The level of d-aspartic acid in rat brain falls rapidly after birth, while the l-aspartic acid level increases with age.  相似文献   

16.
A modified version of capillary isoelectric focusing (cIEF) was developed to separate hemoglobin variants contained within single human erythrocytes. Laser-induced native fluorescence with 275 nm excitation was used to detect the separated hemoglobins. In this method, baseline fluctuations were minimized and detection sensitivity was improved by using dilute solutions of anolyte, catholyte, and carrier ampholytes (with methylcellulose). Since electrosmotic flow was used for mobilization of the focused bands, separation and detection were integrated into a single step. The capillary was first filled with only ampholyte solution, and the cell (or standard) was injected as in capillary zone electrophoresis. The ∼90 fl injection volume for individual cells is 7×104 times lower than those previously reported. Adult (normal and elevated A1), sickle (heterozygous), and fetal erythrocytes were analyzed, with the amounts of hemoglobins A0, A1c, S and F determined. The pH gradient for cIEF was linear (r2 = 0.9984), which allowed tentative identification of Hb Fac. Variants differing by as little as 0.025 pI units were resolved.  相似文献   

17.
Automation is essential for rapid genetic-based mutation analysis in clinical laboratory to screen a large number of DNA samples. We propose in this report an automatic process using Beckman Coulter P/ACE™ capillary electrophoresis (CE) with laser-induced fluorescence (LIF) system to detect a single-point mutation in the codon 12 of human K-ras gene. Polymerase chain reaction (PCR) using a fluorescently labeled reverse primer and a plain forward primer to specifically amplify a selected 50 bp DNA fragment in human K-ras gene. The amplified DNA is placed on the sample tray of the CE system with a pre-programmed step for single-strand conformation polymorphism (SSCP) analysis. Sample injection and denaturation processes are performed online along with separation and real-time data analysis. The concept of automation for rapid DNA mutation analysis using CE-LIF system for SSCP is presented.  相似文献   

18.
A sensitive analytical method for gabapentin [1-(aminomethyl) cyclohexaneacetic acid] (GBP) in human plasma based on capillary electrophoretic separation and laser-induced fluorescence (LIF) detection has been developed. 6-Carboxyfluorescein succinimidyl ester (CFSE) was used for precolumn derivatization of the non-fluorescent drug in plasma. Optimal separation and detection were obtained with an electrophoretic buffer of 50mM sodium borate (pH 9.5) and an air-cooled argon-ion laser (excitation at 488 nm, emission at 520 nm). A calibration curve ranging from 0.3 to 150 microM was shown to be linear. The concentration limit of detection (LOD) in plasma was 60 nM. We also demonstrate how the detection limit can be enhanced by using acetonitrile stacking technique. With stacking, the limit of detection for gabapentin in plasma was 4.8 nM. A calibration curve ranging from 0.03 to 15 microM was shown to be linear. Both the within-day and day-to-day reproducibility and accuracy were 相似文献   

19.
20.
A capillary zone electrophoresis method has been developed for the direct determination of norfloxacin in the physiological perfusate of isolated rat liver. Norfloxacin and the internal standard triamterene were detected using laser-induced fluorescence (LIF) detection with the excitation and emission wavelength of 325 and 435 nm, respectively. The background electrolyte (BGE) was 50 mM phosphate buffer (pH 4.6). The effect of pH and concentration of BGE on the electrophoretic migration and fluorescence response of analytes were examined. Calibration curves were linear over a wide range of 0.01-100 microg/mL. The limit of quantitation was 0.01 microg/mL. The intra- and inter-day relative standard deviation was 3.7%, or less, and the accuracy was 93.2% of the nominal concentration. No endogenous substances were found to interfere. The method was used to characterize the steady-state and transient pharmacokinetics of norfloxacin in the rat liver.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号