首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BackgroundThe purpose of this study was to assess the impact of coincidental radiotherapy on the volume of the non-malignant prostate gland in rectal cancer patients treated with neo-adjuvant radiotherapy.Materials and methodsIn this retrospective analysis, thirty male patients with rectal cancer who had neoadjuvant radiotherapy met the inclusion criteria. These patients had pre-treatment magnetic resonance imaging (MRI) and at least one post-treatment MRI of the pelvis and the whole of their prostate volume received the full prescribed radiotherapy dose; 45 Gy in 25 fractions (n = 22), 45 Gy in 20 fractions (n = 4) and 25 Gy in 5 fractions (n = 4).ResultsThe median age of this patient cohort was 66 years (range: 30–87). With a median interval between pre-treatment MRI and first MRI post-treatment of 2 months (range: 1–11), the mean prostate volume reduced from 36.1 cm3 [standard deviation (SD) 14.2] pre-radiotherapy to 31.3 cm3 (SD 13.0) post radiotherapy and this difference was significant (p = 0.0004).ConclusionRadiotherapy may cause shrinkage in volume of normal (non-malignant) prostate. Further research is required in this field, since these results may be of some comfort to men contemplating the consequences of radiotherapy on their quality of life. The authors suggest recording flow-rate and international prostate symptom score (IPSS) during rectal radiotherapy as a next step.  相似文献   

2.
The objectives of this study were to determine relationships between scrotal size (SC; estimated from a video image) and testicular size, and between ultrasonographic echotexture of the testis and seminiferous tubule area in bulls. Video images of the scrotum of 49 Holstein-Friesian (H-F) bulls were recorded and digitized. Scrotal width and length were measured with custom software. After slaughter, scrotums (containing testes) were excised, SC and testicular height, width and volume were measured, and the testes were examined ultrasonographically. Correlations between SC and testicular width or volume (r = 0.86, P < 0.001 and r = 0.84, P < 0.001, respectively) were much higher than those between scrotal width and testicular width or volume (r = 0.23, P < 0.11 and r = 0.28, P < 0.06). Histological examination of the testes was performed in 31 of the bulls. Ultrasonographic echotexture of the testes (determined with custom software) was highly correlated (r = -0.5, P < 0.005) with seminiferous tubule area. Although SC was superior to video imaging for estimating testicular size, ultrasonographic imaging of the testes has considerable potential for the evaluation of testicular function in bulls.  相似文献   

3.
BackgroundThe calculation and measurement on the surface of the skin presents a significant dosimetric problem because of numerous factors which have an influence on the dose distribution in this region.AimThe overall aim of this study was to check the agreement between doses measured with thermoluminescent detectors (TLD) during tomotherapy photon beam irradiation of the skin area of a solid water cylindrical phantom with doses calculated with Hi-Art treatment planning system (TPS).Material and MethodThe measurements of the dose were made with the use of a solid water cylindrical phantom - Cheese Phantom. Two bolus phantoms were used: 5 mm and 10 mm Six different planning treatments were generated. The doses were measured using TL detectors.ResultsIn the case of a tumor located near the surface of the skin, the mean dose for 0.5 cm bolus was - 1.94 Gy, and for 1 cm bolus - 2.03 Gy. For the tumor located inside the phantom and organ at risk on the same side that TL detectors, for a 0.5 cm bolus, mean dose was 0.658 Gy, and for a 1 cm bolus, 0.62 Gy.ConclusionThe analysis of results showed that the relative percentage difference between measured and planned dose in the field of irradiation was less than 10%, while the largest differences were on the board of the field of radiation and outside of the field of irradiation, where the dose was 0.08 Gy to 1 Gy.  相似文献   

4.
The objective of this study was to determine the contribution of the scrotum, testes, and the testicular artery to scrotal/testicular thermoregulation in bulls at two ambient temperatures. Crossbred beef bulls, 1.5 years of age, were placed in controlled environment chambers at ambient temperatures of 15°C (n = 5) or 25°C (n = 6). The distal lateral aspects and entire ventral part of the scrotum was incised under caudal epidural anaesthesia (xylazine, 0.07 mg kg−1). Both testes were withdrawn from the scrotum and then replaced and maintained by clamping the scrotal incisions with towel clamps. One testis was randomly chosen to be the exposed testis and was withdrawn prior to temperature measurements. Surface and internal temperatures were measured with infrared thermography and needle thermocouples, respectively. Temperature gradients (°C; difference in temperature from top to bottom at 15 and at 25°C) were: scrotal surface (with testis), 1.5 and 1.3; scrotal surface (without testis), 2.1 and 1.6; surface of exposed testis, −0.6 and 0.0; sub-tunic of exposed testis, −2.2 and −0.6; intratesticular (covered testis), 0.0 and 0.4; and intratesticular (exposed testis), −1.3 and 0.4. The scrotum markedly affects testicular temperature but the testes have limited influence on scrotal surface temperature. The bovine scrotum and testes have opposing temperature gradients that complement one another, resulting in a relatively uniform intratesticular temperature. These temperature gradients are attributed in part to the testicular artery, which goes from the top of the testis to the bottom, divides into several branches and ramifies dorsally and laterally before entering the testicular parenchyma. Intra-arterial temperatures (measured with needle thermocouples) were lower (P < 0.05) where the artery entered the testis than at both the bottom and top of the testis for both the covered (31.7, 33.4 and 34.3°C) and exposed testis (29.6, 32.0 and 32.5°C) at an ambient temperature of 15°C. Temperature differences were similar, but less pronounced, at 25°C (covered testis, 34.8, 36.3 and 36.5°C; exposed testis, 32.4, 33.5, 33.9°C). Results supported the hypothesis that blood within the testicular artery has a similar temperature at the top of the testis (just ventral to the testicular vascular cone) compared with the bottom, but subsequently cools before entering the testicular parenchyma.  相似文献   

5.
BackgroundStudy determines differences in calculated dose distributions for non-small cell lung carcinoma (NSC LC) patients. NSC LC cases were investigated, being the most common lung cancer treated by radiotherapy in our clinical practice.Materials and methodsA retrospective study of 15 NSCLC patient dose distributions originally calculated using standard superposition (SS) and recalculated using collapsed cone (CC ) and Monte Carlo (MC) based algorithm expressed as dose to medium in medium (MCDm) and dose to water in medium (MCDw,) was performed so that prescribed dose covers at least 99% of the gross target volume (GTV). Statistical analysis was performed for differences of conformity index (CI), heterogeneity index (HI), gradient index (GI), dose delivered to 2% of the volume (D2%), mean dose (Dmean) and percentage of volumes covered by prescribed dose (V70Gy). For organs at risk (OARs), Dmean and percentage of volume receiving 20 Gy and 5Gy (V20Gy, V5Gy) were analysed.ResultsStatistically significant difference for GTVs was observed between MCDw and SS algorithm in mean dose only. For planning target volumes (PTVs), statistically significant differences were observed in prescribed dose coverage for CC, MCDm and MCDw. The differences in mean CI value for the CC algorithm and mean HI value for MCDm and MCDw were statistically significant. There is a statistically significant difference in the number of MUs for MCDm and MCDw compared to SS.ConclusionAll investigated algorithms succeed in managing the restrictive conditions of the clinical goals. This study shows the drawbacks of the CC algorithm compared to other algorithms used.  相似文献   

6.
The objectives were to determine the effects of age and genetic group on characteristics of the scrotum, testes and testicular vascular cones (TVC), and on sperm production and semen quality in 107 Bos indicus, B. taurus and cross-bred bulls at three artificial insemination (AI) centers in Brazil. In addition, predictors of sperm production and semen quality were identified. In general, scrotal circumference (SC), scrotal shape score, scrotal neck perimeter, and testicular size (length, width and volume) increased (P < 0.05) with age. Although there were no significant differences among genetic groups for SC or testicular size, B. indicus bulls had the least pendulous scrotal shape, the shortest scrotal neck length, and the greatest scrotal neck perimeter (P < 0.05). Fat covering the TVC was thinner (P < 0.05) in bulls < or = 36 months of age and in B. taurus bulls than in older bulls and B. indicus bulls, respectively. Age and genetic group did not affect testicular ultrasonic echotexture. B. indicus bulls tended (P < 0.1) to have the lowest average scrotal surface temperature (SST). In general, ejaculate volume, total number of spermatozoa and number of viable spermatozoa increased (P < 0.05) with age. However, there was no significant effect of age on sperm concentration, motility, major and total defects. The proportion of spermatozoa with minor defects was highest (P < 0.05) in bulls 37-60 months of age. B. indicus bulls had higher (P < 0.01) sperm concentration, total number of spermatozoa and number of viable spermatozoa than B. taurus bulls, with intermediate values for cross-bred bulls. Increased sperm production was associated with increased testicular volume, SC, TVC fat cover, and SST top-to-bottom gradient. Decreased semen quality was associated with increased SC and bottom SST, and decreased scrotal shape, scrotal neck perimeter and vascular cone diameter. In summary, age and genetic group affected the characteristics of the scrotum, testes, and TVC, sperm production and semen quality. In addition, characteristics of the scrotum, testes and TVC were associated with sperm production and semen quality in bulls and could be assessed for breeding soundness evaluation.  相似文献   

7.
8.
BackgroundThe aim was to demonstrate the feasibility and technique of gonadal sparing total body irradiation (TBI) with helical tomotherapy. Total body irradiation is a common part of the conditioning regimen prior to allogeneic stem cell transplantation. Shielding or dose-reduction to the gonads is often desired to preserve fertility, particularly in young patients undergoing transplant for non-malignant indications. Helical tomotherapy (HT) has been shown to be superior to traditional TBI delivery for organ at risk (OA R) doses and dose homogeneity.Materials and methodsWe present two representative cases (one male and one female) to illustrate the feasibility of this technique, each of whom received 3Gy in a single fraction prior to allogeneic stem cell transplant for benign indications. The planning target volume (PTV) included the whole body with a subtraction of OA Rs including the lungs, heart, and brain (each contracted by 1cm) as well as the gonads (testicles expanded by 5 cm and ovaries expanded by 0.5 cm).ResultsFor the male patient we achieved a homogeneity index of 1.35 with a maximum and median planned dose to the testes of 0.53 Gy and 0.35 Gy, respectively. In-vivo dosimetry demonstrated an actual received dose of 0.48 Gy. For the female patient we achieved a homogeneity index of 1.13 with a maximum and median planned dose to the ovaries of 1.66 Gy and 0.86 Gy, respectively.ConclusionGonadal sparing TBI is feasible and deliverable using HT in patients with non-malignant diseases requiring TBI as part of a pre-stem cell transplant conditioning regimen.  相似文献   

9.
10.
PurposeTo increase the superficial dose and reduce the brain dose for radiotherapy of scalp angiosarcoma, we propose a novel irradiation technique of tangential irradiation volumetric modulated arc therapy (TI-VMAT).MethodsTI-VMAT and the conventional VMAT treatment plans for thirteen scalp angiosarcoma patients were created with a prescribed dose of 70 Gy. Each treatment was normalized to cover 95% of the planning target volume (PTV) with its prescribed dose. To realize TI-VMAT, an avoidance structure (AS) function was applied. AS was defined as a contour subtracted PTV by a certain space from the brain contour. TI-VMAT treatment plans for six different spaces between PTV and AS were developed and compared with the conventional VMAT treatment plan with respect to the following dosimetric parameters: homogeneity index (HI) and conformity index (CI) of the PTV, mean brain dose, and brain volume irradiated with 20% (V20% [cc]), 40% (V40% [cc]), 60% (V60% [cc]), 80% (V80% [cc]), and 100% (V100% [cc]) of the prescribed dose.ResultsHI and CI were comparable between TI-VMAT and the conventional VMAT, the mean brain dose for TI-VMAT with AS defined by a space of 2.0 cm and jaw tracking was 14.27 Gy, which was significantly lower than that for the conventional VMAT (21.20 Gy). In addition, dosimetric parameters such as V20% [cc] were significantly suppressed compared to those for high doses.ConclusionOur proposed irradiation technique TI-VMAT shows the potential to reduce radiation doses in the brain with maintaining higher dose coverage on the PTV.  相似文献   

11.
PurposesSeveral studies have shown that simultaneous integrated boost provides better dose homogeneity, improves the biologically effective dose-volume histogram and reduces treatment time compared to sequential boost in breast cancer.Patients and methodsWe conducted a systematic review of published trials evaluating simultaneous integrated boost in hypofractionated radiotherapy to analyze the results in terms of overall survival, local control, early and late side effects, and radiotherapy techniques used.ResultsUpon 9 articles, the prescribed dose to the whole breast varied from 40 to 46.8 Gy. The number of fractions varies from 15 to 20 fractions. The prescribed dose per fraction to the boost varied from 2.4 Gy per fraction to 3.4 Gy per fraction for a total boost dose from 48 to 52.8 Gy.ConclusionsSimultaneous integrated boost seems effective and safe when given hypofractionated whole-breast irradiation but needs to be validated in prospective trials.  相似文献   

12.
AimThe investigation of the irradiation time calculation accuracy of the GGPB algorithm used for IORT.BackgroundConventionally, breast conserving therapy consists of breast conserving surgery followed by postoperative whole breast irradiation and boost. The use of intraoperative radiotherapy (IORT) enables the boost to be delivered already during the surgery. In this case, the treatment dose for IORT can be calculated by use of General Gaussian Pencil Beam (GGPB) algorithm, which is implemented in TPS Eclipse.Materials and methodsPDDs and OFs for electron beams from Mobetron and all available applicators were measured in order to configure the GGPB algorithm. Afterwards, the irradiation times for the prescribed dose of 3 Gy were calculated by means of it. The results of calculations were verified in the water phantom using the Marcus ionization chamber.ResultsThe results differed between energies. For 6 MeV the irradiation times calculated by the GGPB algorithm were correct, for the energy of 9 MeV they were too small and for the energy of 4 MeV they were too large for applicators with smaller diameters, while acceptable for the remaining ones.ConclusionThe GGPB algorithm can be used in intraoperative radiotherapy for energy and applicator sets for which no significant difference between the measured and the prescribed dose was obtained. For the rest of energy-applicator sets the configuration should be verified and possibly repeated.  相似文献   

13.
PurposeTo assess out-of-field doses in radiotherapy treatments of paediatric patients, using Monte Carlo methods to implement a new model of the linear accelerator validated against measurements and developing a voxelized anthropomorphic paediatric phantom.MethodsCT images of a physical anthropomorphic paediatric phantom were acquired and a dosimetric planning using a TPS was obtained. The CT images were used to perform the voxelization of the physical phantom using the ImageJ software and later implemented in MCNP. In order to validate the Monte Carlo model, dose measurements of the 6 MV beam and Linac with 120 MLC were made in a clinical setting, using ionization chambers and a water phantom. Afterwards TLD measurements in the physical anthropomorphic phantom were performed in order to assess the out-of-field doses in the eyes, thyroid, c-spine, heart and lungs.ResultsThe Monte Carlo model was validated for in-field and out-of-field doses with average relative differences below 3%. The average relative differences between TLD measurements and Monte Carlo is 14,3% whilst the average relative differences between TLD and TPS is 55,8%. Moreover, organs up to 22.5 cm from PTV center show TLD and MCNP6 relative differences and TLD and TPS relative differences up to 21.2% and 92.0%, respectively.ConclusionsOur study provides a novel model that could be used in clinical research, namely in dose evaluation outside the treatment fields. This is particularly relevant, especially in pediatric patients, for studying new radiotherapy treatment techniques, since it can be used to estimate the development of secondary tumours.  相似文献   

14.
15.
In this work, dose measurements were performed to evaluate an external radiotherapy treatment plan and, particularly, to validate dose calculations for a lung lesion case. Doses were calculated by the Varian Eclipse treatment planning system using the AAA anisotropic analytical algorithm. The measurements were performed using a Rando anthropomorphic phantom and TLD700 thermoluminescent dosimeters. The comparison between doses calculated and doses measured by means of thermoluminescence (TL) shows compatibility except for a few points, due to the limitations in the heterogeneity correction used for the case studied here. The deviation between the calculated and measured doses is about 6.5% for low (<?0.5 Gy) doses and about 1% for higher doses (>?0.5 Gy).The deviation between AAA-calculated and TL-measured doses was also found to be higher in proximity to heterogeneous tissue interfaces.  相似文献   

16.
PurposeRetrospective, single-institution analysis of clinical outcomes and treatment-related toxicity in patients treated with salvage I-125 low-dose rate (LDR) brachytherapy (BT) for locally-recurrent prostate cancer after radiotherapy.Materials and methodsBetween 2008 and 2018, 30 patients with biopsy-confirmed prostate cancer recurrence underwent salvage treatment with I-125 LDR-BT. Of these 30 patients, 14 were previously treated with primary external beam radiotherapy (EBRT; median dose, 73 Gy) and 16 with primary I-125 LDR-BT (145 Gy and 160 Gy in 14 and 2 cases, respectively). At seed implantation, the mean age was 75.8 years, with a median Gleason score of 7 and pre-salvage PSA of <10 ng/mL. Six patients received androgen deprivation therapy for six months after relapse diagnosis. The prescribed salvage I-125 BT dose to the gland was 120−130 Gy, with dose restrictions of Dmax <135% (urethra) and <100% (rectum). Toxicity was evaluated according to the CTCAE scale (v4.0).ResultsAt a median follow-up of 45 months, the biochemical recurrence-free survival rates at 1, 3 and 5 years were 86.7%, 56.7% and 53.3%, respectively. Overall survival at 5 years was 87%. On the multivariate analysis, two variables were significant predictors of recurrence: PSA at relapse and nadir PSA post-salvage. Grade 3 genitourinary toxicity was observed in 5 patients (radiation-induced cystitis in 3 cases and urethral stenosis in 2) and G3 gastrointestinal toxicity in 3 patients (rectal bleeding).ConclusionSalvage therapy with I-125 brachytherapy is a safe and effective treatment option for locally-recurrent prostate cancer in previously-irradiated patients. High pre-salvage PSA and post-salvage nadir PSA values were significantly associated with a worse disease control after salvage I-125 LDR-BT. In well-selected patients, I-125 LDR-BT is comparable to other salvage therapies in terms of disease control and toxicity. However, more research is needed to determine the optimal management of locally-recurrent prostate cancer.  相似文献   

17.
PurposeEvaluating performance of modern dose calculation algorithms in SBRT and locally advanced lung cancer radiotherapy in free breathing (FB) and deep inspiration breath hold (DIBH).MethodsFor 17 patients with early stage and 17 with locally advanced lung cancer, a plan in FB and in DIBH were generated with Anisotropic Analytical Algorithm (AAA). Plans for early stage were 3D-conformal SBRT, 45 Gy in 3 fractions, prescribed to 95% isodose covering 95% of PTV and aiming for 140% dose centrally in the tumour. Locally advanced plans were volumetric modulated arc therapy, 66 Gy in 33 fractions, prescribed to mean PTV dose. Calculation grid size was 1 mm for SBRT and 2.5 mm for locally advanced plans. All plans were recalculated with AcurosXB with same MU as in AAA, for comparison on target coverage and dose to risk organs.ResultsLung volume increased in DIBH, resulting in decreased lung density (6% for early and 13% for locally-advanced group).In SBRT, AAA overestimated mean and near-minimum PTV dose (p-values < 0.01) compared to AcurosXB, with largest impact in DIBH (differences of up to 11 Gy). These clinically relevant differences may be a combination of small targets and large dose gradients within the PTV.In locally advanced group, AAA overestimated mean GTV, CTV and PTV doses by median less than 0.8 Gy and near-minimum doses by median 0.4–2.7 Gy.No clinically meaningful difference was observed for lung and heart dose metrics between the algorithms, for both FB and DIBH.ConclusionsAAA overestimated target coverage compared to AcurosXB, especially in DIBH for SBRT.  相似文献   

18.
PurposeTo compare abdominal imaging dose from 3D imaging in radiology (standard/low-dose/dual-energy CT) and radiotherapy (planning CT, kV cone-beam CT (CBCT)).MethodsDose was measured by thermoluminescent dosimeters (TLD’s) placed at 86 positions in an anthropomorphic phantom. Point, organ and effective dose were assessed, and secondary cancer risk from imaging was estimated.ResultsOverall dose and mean organ dose comparisons yield significantly lower dose for the optimized radiology protocols (dual-source and care kV), with an average dose of 0.34±0.01 mGy and 0.54±0.01 mGy (average ± standard deviation), respectively. Standard abdominal CT and planning CT involve considerably higher dose (13.58 ± 0.18 mGy and 18.78±0.27 mGy, respectively). The CBCT dose show a dose fall-off near the field edges. On average, dose is reduced as compared with the planning or standard CT (3.79 ± 0.21 mGy for 220° rotation and 7.76 ± 0.37 mGy for 360°), unless the high-quality setting is chosen (20.30 ± 0.96 mGy). The mean organ doses show a similar behavior, which translates to the estimated secondary cancer risk. The modelled risk is in the range between 0.4 cases per million patient years (PY) for the radiological scans dual-energy and care kV, and 300 cases per million PY for the high-quality CBCT setting.ConclusionsModern radiotherapy imaging techniques (while much lower in dose than radiotherapy), involve considerably more dose to the patient than modern radiology techniques. Given the frequency of radiotherapy imaging, a further reduction in radiotherapy imaging dose appears to be both desirable and technically feasible.  相似文献   

19.
We evaluated the effects of l-carnitine on apoptosis of germ cells in the rat testis following irradiation. Male Wistar rats were divided into three groups. Control group received sham irradiation plus physiological saline. Radiotherapy group received scrotal gamma-irradiation of 10 Gy as a single dose plus physiological saline. Radiotherapy + l-carnitine group received scrotal irradiation plus 200 mg/kg intraperitoneally l-carnitine. Twenty-four hours post-irradiation, the rats were sacrificed and testes were harvested. Testicular damage was examined by light and electron microscopy, and germ cell apoptosis was determined by terminal deoxynucleotidyltransferase-mediated deoxyuridine triphosphate in situ nick end-labeling (TUNEL) technique. Morphologically, examination of irradiated testis revealed presence of disorganization and desquamation of germinal cells and the reduction in sperm count in seminiferous tubule lumen. Under electron microscopy, the morphological signs of apoptosis were frequently detected in spermatogonia. Apoptotic spermatogonia showed the marginal condensation of chromatin onto the nuclear lamina, nucleus and cytoplasm shrinkage and still functioning cell organelles. TUNEL-positive cells were significantly more numerous in irradiated rats than in control rats. l-carnitine treatment significantly attenuated the radiation-induced morphological changes and germ cell apoptosis in the irradiated rat testis. In conclusion, these results suggested that l-carnitine supplementation during the radiotherapy may be beneficial for spermatogenesis following testicular irradiation by decreasing germ cell apoptosis.  相似文献   

20.
This study aims to estimate testicular dose and the associated risks for infertility and hereditary effects from inverted-Y field irradiation Radiotherapy was simulated on a humanoid phantom using a 6 MV photon beam. Testicular dose was measured for various field sizes and tissue thicknesses along beam axis using an ionization chamber. Gonadal dose was reduced by placing lead cups around the testes supplemented by a field edge block. For a tumor dose of 40 Gy, testicular dose was 0.56–6.52 Gy depending upon the field size and the distance from the inferior field edge. The corresponding dose to shielded testes was 0.12–1.96 Gy. The increase of tissue thickness in reased the testicular dose up to 40%. An excess risk of hereditary disorders of (7–391) per 10000 births was calculated. The treatment parameters, the presence of gonad shield and the somatometric characteristics determine whether testicular dose can exceed 1 Gy which allows a complete recovery of spermatogenesis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号