首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
目的:利用恒定均匀磁场研究了不同磁处理方式和磁感应强度对小球藻生长的影响,探索磁处理技术应用于微藻培养的可能。方法:用t检验考察静止磁处理、循环磁处理和磁处理水三种不同的磁处理方式对小球藻生长的影响。结果:静止磁处理和循环磁处理分别在5.15mT和10.35mT范围促进小球藻生长,并且随磁感应强度增强分别从45mT与200mT开始表现出显著抑制生长作用.相同的磁感应强度下静止磁处理比循环磁处理的影响显著。未发现磁处理水对小球藻的生长有显著影响。结论:不同的磁处理方式对小球藻生长有不同的刺激与抑制的强度闽值;0.8T和1.2T磁感应强度处理下比生长速率下降的差别并不明显,说明磁处理的影响在此强度范围趋于稳定;磁处理水无显著影响说明磁场直接对小球藻细胞产生影响。  相似文献   

2.
Threshold image intensity for reconstructing patient-specific vascular models is generally determined subjectively. We assessed the effects of threshold image intensity differences on computational fluid dynamics (CFD) using a simple method of threshold determination. This study included 11 consecutive patients with internal carotid artery aneurysms collected retrospectively between April 2009 and March 2010. In 3-dimensional rotational angiography image data, we set a line probe across the coronal cross-section of the parent internal carotid artery, and calculated a profile curve of the image intensity along this line. We employed the threshold coefficient (C(thre)) value in this profile curve, in order to determine the threshold image intensity objectively. We assessed the effects of C(thre) value differences on vascular model configuration and the wall shear stress (WSS) distribution of the aneurysm. The threshold image intensity increased as the C(thre) value increased. The frequency of manual editing increased as the C(thre) value decreased, while disconnection of the posterior communicating artery occurred more frequently as the C(thre) value increased. The volume of the vascular model decreased and WSS increased according to the C(thre) value increase. The pattern of WSS distribution changed remarkably in one case. Threshold image intensity differences can produce profound effects on CFD. Our results suggest the uniform setting of C(thre) value is important for objective CFD.  相似文献   

3.
Repetitive transcranial magnetic stimulation of the motor cortex (rTMS) can be used to modify motor cortical excitability in human subjects. At stimulus intensities near to or above resting motor threshold, low-frequency rTMS (approximately 1 Hz) decreases motor cortical excitability, whereas high-frequency rTMS (5-20 Hz) can increase excitability. We investigated the effect of 10 min of intermittent rTMS on motor cortical excitability in normal subjects at two frequencies (2 or 6 Hz). Three low intensities of stimulation (70, 80, and 90% of active motor threshold) and sham stimulation were used. The number of stimuli were matched between conditions. Motor cortical excitability was investigated by measurement of the motor-evoked potential (MEP) evoked by single magnetic stimuli in the relaxed first dorsal interosseus muscle. The intensity of the single stimuli was set to evoke baseline MEPs of approximately 1 mV in amplitude. Both 2- and 6-Hz stimulation, at 80% of active motor threshold, reduced the magnitude of MEPs for approximately 30 min (P < 0.05). MEPs returned to baseline values after a weak voluntary contraction. Stimulation at 70 and 90% of active motor threshold and sham stimulation did not induce a significant group effect on MEP magnitude. However, the intersubject response to rTMS at 90% of active motor threshold was highly variable, with some subjects showing significant MEP facilitation and others inhibition. These results suggest that, at low stimulus intensities, the intensity of stimulation may be as important as frequency in determining the effect of rTMS on motor cortical excitability.  相似文献   

4.
To calibrate the intensity of transcranial magnetic stimulation (TMS) at the occipital pole, the phosphene threshold is used as a measure of cortical excitability. The phosphene threshold (PT) refers to the intensity of magnetic stimulation that induces illusory flashes of light (phosphenes) on a proportion of trials. The existing PT estimation procedures lack the accuracy and mathematical rigour of modern threshold estimation methods. We present an improved and automatic procedure for estimating the PT which is based on the well-established Ψ Bayesian adaptive staircase approach. To validate the new procedure, we compared it with another commonly used procedure for estimating the PT. We found that our procedure is more accurate, reliable, and rapid when compared with an existing PT measurement procedure. The new procedure is implemented in Matlab and works automatically with the Magstim Rapid(2) stimulator using a convenient graphical user interface. The Matlab program is freely available for download.  相似文献   

5.
An important aspect of experimental pain research is that the assessment methods can investigate the different aspects of pain perception. The aim of the present study was to investigate the influence of rate of temperature change and peak stimulus duration on heat evoked pain intensity and quality. All stimuli were applied within the medial aspect of the anterior forearm. The rate of temperature change was varied from 1 to 16 C/s without any effect on the pain threshold. The pain threshold decreased with an increasing peak stimulus duration from 0.1 to 2 s, but not from 2 to 3 s. The pain intensity for suprathreshold stimuli (46 C, 48 C, 50 C) increased for decreasing rates and increasing duration. The pain intensity was highly correlated with the energy of the stimulus. When the rates of temperature change (1-16 C/s) are varied, no differences between pricking and burning pain were present at either low stimulus intensity (46 C) or high stimulus intensity (50 C). At low stimulus intensity (46 C), the pricking pain was not influenced by the duration (0.1-3 s), but the burning pain was intensified when the duration was increased from 1.5 to 3 s. At high intensity stimuli (50 C), the pricking pain intensified with an increased duration, whereas burning pain did not. The heat pain threshold is influenced by the peak stimulus duration, and not by the rate of temperature change. If suprathreshold stimuli are used, both the rate of temperature change and the peak stimulus duration can strongly affect the pain intensity and the pain quality. Therefore, the same stimulus modality can be used to assess the modulation of different pain intensities and of the pricking and burning pain qualities simply by varying the stimulus configuration.  相似文献   

6.
This study was to describe and compare the physiological demands of ultra-endurance cyclists during a 24 h cycling relay race. Eleven male athletes (means +/- SD: 34.8 +/- 5.6 years; 71.6 +/- 4.9 kg; 174.6 +/- 7.3 cm; BMI 23.5 +/- 0.5 kg/m2; VO2 max: 66.0 +/- 6.4 ml/kg/min) participated in the study; eight in teams with a format of four riders (4C) and three in teams with six riders (6C). To investigate exercise intensity, heart rate (HR) was recorded while cycling using portable telemetric monitors. Three different exercise intensities were defined according to the reference HR values obtained during a pre race laboratory incremental VO2 max test: Zone I (< anaerobic threshold [AT]), Zone II (between AT and the respiratory compensation point [RCP]), Zone III (> RCP). Total volume and intensity were integrated as a single variable (training impulse: TRIMP). The score for TRIMP in each zone was computed by multiplying the accumulated duration in this zone by a multiplier for this particular zone of exercise intensity. The average intensity did not differ between cyclists in 4C (means +/- SD; 4C: 87 +/- 3 HRmax) and 6C (87 +/- 1% of HRmax), despite the higher volume performed by 4C (means +/- SD; 4C: 361 +/- 65; 6C: 242 +/- 25 per min; P = 0.012). These differences in total exercise volume significantly affected the values TRIMP accumulated (means +/- SD; 4C: 801 +/- 98, confidence interval [CI] 95%: 719 - 884; 6C: 513 +/- 25, CI 95%: 451 - 575; P = 0.012). The ultra-endurance threshold of 4C and 6C athletes lies at about 87% of HRmax for both. Although the intensity profile was similar, the TRIMP values differed significantly as a consequence of the higher volume performed by the 4C cyclists.  相似文献   

7.
The hypothesis that the magnitude of the postexercise onset threshold for sweating is increased by the intensity of exercise was tested in eight subjects. Esophageal temperature was monitored as an index of core temperature while sweat rate was measured by using a ventilated capsule placed on the upper back. Subjects remained seated resting for 15 min (no exercise) or performed 15 min of treadmill running at either 55, 70, or 85% of peak oxygen consumption (V(o2 peak)) followed by a 20-min seated recovery. Subjects then donned a liquid-conditioned suit used to regulate mean skin temperature. The suit was first perfused with 20 degrees C water to control and stabilize skin and core temperature before whole body heating. Subsequently, the skin was heated ( approximately 4.0 degrees C/h) until sweating occurred. Exercise resulted in an increase in the onset threshold for sweating of 0.11 +/- 0.02, 0.23 +/- 0.01, and 0.33 +/- 0.02 degrees C above that measured for the no-exercise resting values (P < 0.05) for the 55, 70, and 85% of V(o2 peak) exercise conditions, respectively. We did note that there was a greater postexercise hypotension as a function of exercise intensity as measured at the end of the 20-min exercise recovery. Thus it is plausible that the increase in postexercise threshold may be related to postexercise hypotension. It is concluded that the sweating response during upright recovery is significantly modified by exercise intensity and may likely be influenced by the nonthermal baroreceptor reflex adjustments postexercise.  相似文献   

8.
Five groups of pregnant Sprague-Dawley rats were irradiated for 10-40 min on gestation day 9 in a 27.12-MHz radiofrequency field at a magnetic field strength of 55 A/m and an electric field strength of 300 V/m. The specific absorption rate was 10.8 +/- 0.3 W/kg. Exposures were terminated after the rat's colonic temperature reached 41.0 degrees C, 41.5 degrees C, 42.0 degrees C, 42.5 degrees C, or 43.0 degrees C. A control group was sham irradiated at 0 A/m and 0 V/m on gestation day 9, whereas a second control group was untreated. The incidence of both birth defects and prenatal death was directly related to maternal body temperature once a temperature threshold was exceeded. The temperature threshold for both types of effects was approximately 41.5 degrees C. A few pregnant rats died after exposure to 43.0 degrees C, and higher temperatures were nearly always lethal.  相似文献   

9.
M G Yost  R P Liburdy 《FEBS letters》1992,296(2):117-122
We have tested the hypothesis that extremely low frequency (ELF) time-varying magnetic fields act in combination with static magnetic fields to alter calcium signalling in the lymphocyte. Results indicate that a 60-min exposure of thymic lymphocytes at 37 +/- 0.05 degrees C to a 16 Hz, 421 mG (42.1 microT) magnetic field simultaneously with a colinear static magnetic field of 234 mG (23.4 microT) (a.c./d.c. field intensity ratio = 1.8) inhibits calcium influx triggered by the mitogen Concanavalin A. Significantly, resting lymphocytes do not respond to the fields, thus, only mitogen-activated cells undergoing calcium signalling exhibit a field response. These results indicate that signal transduction involving calcium is an important biological constraint which operates to mediate this field interaction. Additional split field exposures show that the presence of the a.c. field or the d.c. field alone does not produce an effect. This is consistent with a proposed parametric resonance theory of interaction of low intensity magnetic fields with biological systems (L.L. Lednev (1991) Bioelectromagnetics 12, 71-75), which predicts the occurrence of biological effects at specific values for the frequency and field intensity of the ELF and static magnetic fields.  相似文献   

10.
1. Sharp fluctuation of the intensity of the vertical component of the MF amounting to +/- 0.1 Oe changing the sign over each 3 min causes variability of both lysogenic and indicator strains of E. coli. This testifies to an extremely low threshold of their magnetic susceptibility and to biological importance of fluctuations of natural parameters of the geomagnetic field as an ecological factor of the environment. 2. A change in the intensity of the vertical component of the MF, not any higher than +/-0.1 Oe, inhibits phage production in the lysogenic system of E. coli K = 12 lambda and is also reflected in the morphological peculiarities of negative phage colonies as well as in the phage-susceptibility of the E. coli indicator strain.  相似文献   

11.
A conceptual model is proposed for the encoding of magnetic field intensity from the motion of a chain of single-domain magnetite crystals which is located within a receptor cell, connected at one end to the cell membrane, and linked by cytoskeletal filaments to an array of mechanically gated ion channels centred on the end of the chain. In this arrangement, the physical links between the chain and ion channels will restrict the motion of the magnetite chain in response to the external magnetic field to a narrow cone with its axis through the point where the chain is attached to the membrane. The motion of the chain in the presence of an external magnetic field and thermal agitation will open a varying number of channels, causing the membrane potential to oscillate about some mean value that depends on the component of magnetic intensity oriented perpendicular to the cell membrane. The model permits estimation of magnetic intensity by integration of the motion of the magnetite chain over an area of the cell membrane, explains a number of results from physiological recordings in birds and fish, and makes testable predictions for future experimental studies. The model also provides a mechanism at the cellular level for a constant value of the Weber fraction (the ratio of the threshold sensitivity to a stimulus and the magnitude of that stimulus) for the magnetic sense but requires a separate gain control mechanism for modulation of sensitivity over a range of background fields. If magnetic field detection and encoding works as proposed in the model, the magnetoreceptor system may also be able to reconstruct the magnetic field vector using information about the vertical and horizontal axes from the eyes, gravity detectors, or both.  相似文献   

12.
Understanding exposure thresholds for the response of biological systems to extremely low frequency (ELF) electric and magnetic fields is a fundamental problem of long-standing interest. We consider a two-state model for voltage-gated channels in the membrane of an isolated elongated cell (Lcell = 1 mm; rcell = 25 micron) and use a previously described process of ionic and molecular flux rectification to set lower bounds for a threshold exposure. A key assumption is that it is the ability of weak physical fields to alter biochemistry that is limiting, not the ability of a small number of molecules to alter biological systems. Moreover, molecular shot noise, not thermal voltage noise, is the basis of threshold estimates. Models with and without stochastic resonance are used, with a long exposure time, texp = 10(4) s. We also determined the dependence of the threshold on the basal transport rate. By considering both spherical and elongated cells, we find that the lowest bound for the threshold is Emin approximately 9 x 10(-3) V m-1 (9 x 10(-5) V cm-1). Using a conservative value for the loop radius rloop = 0.3 m for induced current, the corresponding lower bound in the human body for a magnetic field exposure is Bmin approximately 6 x 10(-4) T (6 G). Unless large, organized, and electrically amplifying multicellular systems such as the ampullae of Lorenzini of elasmobranch fish are involved, these results strongly suggest that the biophysical mechanism of voltage-gated macromolecules in the membranes of cells can be ruled out as a basis of possible effects of weak ELF electric and magnetic fields in humans.  相似文献   

13.
Effect of the constant magnetic field with up to 3.2 X 10(-4) A/m intensity on the fluorescence of papain aqueous solutions was investigated. It has been shown that depending on the magnetic field direction a reversible decrease or increase of fluorescence intensity takes place. The variation of fluorescence intensity under the influence of magnetic field is maximal under excitation at long wave ultra-violet light. The effect increases with the increase of temperature, increases linearly with the increase of magnetic field intensity but doesn't depend on protein concentration in diluted solutions. The examination of the data leads to the conclusion on the existence of two possible mechanisms: the variation of properties of surface tryptophan residues environment and paramagnetic orientation of protein globule under the influence of a magnetic field.  相似文献   

14.
The inhibitive effect of static magnetic field on the activity of lysozyme was studied using acoustic wave impedance analysis technique. Equivalent circuit parameters of piezoelectric quartz crystal (PQC) were obtained and discussed. The results showed that the activity of lysozyme was inhibited due to the effect of static magnetic field and the inhibitive effect becomes greater with an increase in magnetization time or magnetic field intensity. According to the response characteristics of motional resistance change (deltaR1), which is related to the change in the bacterial number, a quantitative response model reflecting the activity of lysozyme was theoretically derived. By fitting deltaR1 versus time curves under a specific magnetic field intensity but different magnetic time to the model, the relationship between K1 reflecting the activity of lysozyme and magnetic time t(m) was established. Based on the relationship, a new impedance response model that indicates the inhibitive influence of the magnetization time on the activity of lysozyme was derived as follows: deltaR1 = R0((K4(exp[K0exp(-0.26t(m))]t - 1) + 1)1/2 - 1). Similarly, another response model that indicates the effect of magnetic field intensity was derived as follows: deltaR1 = R0((K4(exp(K0 exp(- 5.17B)t) - 1) + 1)1/2 - 1).  相似文献   

15.
Nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance imaging (MRI) were used to analyse changes in the physical state of water in wheat crowns during cold acclimation and during the freezing/thawing cycle. Spectroscopically measured average spin-spin relaxation times (T2) decreased during cold acclimation and increased when plants were grown at normal temperature. Spin-spin relaxation images whose contrast is proportional to T2, times were calculated allowing association of water relaxation with regions of tissue in spin-echo images during acclimation and freezing. Images taken during freezing revealed nonuniform freezing of tissue in crowns and roots. Acclimated and non-acclimated wheat crowns were imaged during freezing and after thawing. Spin-echo image signal intensity and T2 times decreased dramatically between -4°C and -8°C as a result of a decrease in water mobility during freezing. Images collected during thawing were diffuse with less structure and relaxation times were longer, consistent with water redistribution in tissue after membrane damage.  相似文献   

16.
The previous observation with an electron microscope showed that extremely low frequency (ELF) pulsed magnetic field (PMF) (with the maximum intensity of 0. 6-2. 0 T, gradient of 10-100 T. M-1, pulse width of 20-200 ms and frequency of 0. 16-1. 34 Hz) inhibited the growth of S-180 sarcoma in mice and enhanced the ability of immune cell's dissolving sarcoma cells. In this study, the DNA contents of nuclei were assayed by using Faulgen Staining method. With an electron microscope and cell stereoscopy technology it was observed that magnetic field affected the sarcoma cell's metabolism, lowered its malignancy, and restrained its rapid and heteromorphic growth. The magnetic field enhanced the cellular immune ability and the reaction of lymphocytes and plasma. Since ELF pulsed magnetic fields can inhibit the growth of sarcomas and enhance the cellular immune ability, it is possible to use it as a new method to treat cancer.  相似文献   

17.
研究了不同强度采伐干扰对土壤表层(3~5 cm)温度空间异质性和空间格局的影响.在帽儿山地区天然次生林内,设置3块不同强度采伐干扰处理样地: A(对照)、B(按基面积的50%随机采伐)和C(皆伐),分别布设不同空间距离 (0.5~56 m)的取样点160、154和154个,比较了干扰以后2年内春季和夏季(共4次)土壤表层温度的空间异质性和空间格局特征.结果表明,森林采伐后,土壤表层平均温度显著增加(相差0.6~4.2 ℃,P<0.001),与干扰强度存在一定程度正相关,温度波动范围加大.采伐干扰导致土壤表层温度空间异质性程度和变异尺度增加,并随干扰强度加大而增大,小尺度上的空间异质性也出现增加现象,但土壤温度空间变异尺度主要体现在<20 m范围内,空间异质性组成受干扰影响较小.经Kriging法对土壤表层温度空间格局模拟,发现采伐干扰样地土壤表层温度的空间格局强度较对照林地大,温度等值线密集,其差异春季比夏季明显.采伐干扰样地的年际间相同季节土壤表层温度格局较相似,而对照样地则呈较均匀的分布格局.  相似文献   

18.
The aim of this work was the validation of a rapid, real-time PCR assay based on TaqMan technology for the unequivocal identification of Salmonella spp. to be used directly on an agar-grown colony. A real-time PCR system targeting at the Salmonella spp. invA gene was optimized and validated through a four times repeated blind experiment performed in two different laboratories including 50 Salmonella spp. with representative strains from each of the 5 different Salmonella subgenera and 30 non-Salmonella strains. Both parameters DeltaR(n) (fluorescence intensity of template through a normalized reporter value) and C(T) (cycle at which the fluorescence intensity achieved a pre-established threshold) were analyzed. Overall mean DeltaR(n) and C(T) values for Salmonella strains (2.14+/-0.87 and 15.30+/-0.90, respectively) were statistically different from values for non-Salmonella strains, allowing the establishment of cut-off DeltaR(n) and C(T) values based on 95% confidence intervals that allowed the correct identification of all strains tested in each independent experiment. The accuracy of this assay in terms of inclusivity and exclusivity was 100%. Moreover, the PCR system proved to be especially convenient because the pre-mix containing all PCR reagents except for the bacterial cells could be kept at -20 degrees C for at least 1 month before its use. The optimized TaqMan real-time PCR assay is a useful, simple and rapid method for routine identification of Salmonella spp., irrespective of the particular subgenus.  相似文献   

19.
A model of magnetoreception proposes that the avian magnetic compass is based on a radical pair mechanism, with photon absorption leading to the formation of radical pairs. Analyzing the predicted light dependency by testing migratory birds under monochromatic lights, we found that the responses of birds change with increasing intensity. The analysis of the orientation of European robins under 502 nm turquoise light revealed two types of responses depending on light intensity: under a quantal flux of 8.10(15) quanta m(-2) s(-1), the birds showed normal migratory orientation in spring as well as in autumn, relying on their inclination compass. Under brighter light of 54.10(15) quanta m(-2) s(-1), however, they showed a "fixed" tendency toward north that did not undergo the seasonal change and proved to be based on magnetic polarity, not involving the inclination compass. When birds were exposed to a weak oscillating field, which specifically interferes with radical pair processes, the inclination compass response was disrupted, whereas the response to magnetic polarity remained unaffected. These findings indicate that the normal inclination compass used for migratory orientation is based on a radical-pair mechanism, whereas the fixed direction represents a novel type of light-dependent orientation based on a mechanism of a different nature.  相似文献   

20.
Lipid bilayers of dimyristoyl phosphatidylcholine (DMPC) containing opioid peptide dynorphin A(1-17) are found to be spontaneously aligned to the applied magnetic field near at the phase transition temperature between the gel and liquid crystalline states (T(m)=24 degrees C), as examined by 31P NMR spectroscopy. The specific interaction between the peptide and lipid bilayer leading to this property was also examined by optical microscopy, light scattering, and potassium ion-selective electrode, together with a comparative study on dynorphin A(1-13). A substantial change in the light scattering intensity was noted for DMPC containing dynorphin A(1-17) near at T(m) but not for the system containing A(1-13). Besides, reversible change in morphology of bilayer, from small lipid particles to large vesicles, was observed by optical microscope at T(m). These results indicate that lysis and fusion of the lipid bilayers are induced by the presence of dynorphin A(1-17). It turned out that the bilayers are spontaneously aligned to the magnetic field above T(m) in parallel with the bilayer surface, because a single 31P NMR signal appeared at the perpendicular position of the 31P chemical shift tensor. In contrast, no such magnetic ordering was noted for DMPC bilayers containing dynorphin A(1-13). It was proved that DMPC bilayer in the presence of dynorphin A(1-17) forms vesicles above T(m), because leakage of potassium ion from the lipid bilayers was observed by potassium ion-selective electrode after adding Triton X-100. It is concluded that DMPC bilayer consists of elongated vesicles with the long axis parallel to the magnetic field, together with the data of microscopic observation of cylindrical shape of the vesicles. Further, the long axis is found to be at least five times longer than the short axis of the elongated vesicles in view of simulated 31P NMR lineshape.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号