共查询到20条相似文献,搜索用时 10 毫秒
1.
Parkin MC Turfus SC Smith NW Halket JM Braithwaite RA Elliott SP Osselton MD Cowan DA Kicman AT 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,876(1):137-142
Current analytical methods used for screening drugs and their metabolites in biological samples from victims of drug-facilitated sexual assault (DFSA) or other vulnerable groups can lack sufficient sensitivity. The application of liquid chromatography, employing small particle sizes, with tandem mass spectrometry (MS/MS) is likely to offer the sensitivity required for detecting candidate drugs and/or their metabolites in urine, as demonstrated here for ketamine. Ultra-performance liquid chromatography-mass spectrometry (UPLC-MS/MS) was performed following extraction of urine (4 mL) using mixed-mode (cation and C8) solid-phase cartridges. Only 20 microL of the 250 microL extract was injected, leaving sufficient volume for other assays important in DFSA cases. Three ion transitions were chosen for confirmatory purposes. As ketamine and norketamine (including their stable isotopes) are available as reference standards, the assay was additionally validated for quantification purposes to study elimination of the drug and primary metabolite following a small oral dose of ketamine (50 mg) in 6 volunteers. Dehydronorketamine, a secondary metabolite, was also analyzed qualitatively to determine whether monitoring could improve retrospective detection of administration. The detection limit for ketamine and norketamine was 0.03 ng/mL and 0.05 ng/mL, respectively, and these compounds could be confirmed in urine for up to 5 and 6 days, respectively. Dehydronorketamine was confirmed up to 10 days, providing a very broad window of detection. 相似文献
2.
Uric acid is a potent antioxidant and scavenger of singlet oxygen and other radicals in humans. Allantoin, the predominant product of free radical-induced oxidation of uric acid, is efficiently excreted in the urine and has potential as a biomarker of oxidative stress. We developed a rapid and specific assay for urinary allantoin using ultra-performance liquid chromatography-tandem mass spectrometry suitable for high-throughput clinical studies. The method required minimal sample preparation and was accurate (mean error = 6%), precise (intra- and interday imprecision <8%), and sensitive (limit of detection = 0.06 pmol). Allantoin levels measured in control samples were comparable to literature values. 相似文献
3.
Li Y Sun Y Dong Y Zhang Y Zhong D 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2006,830(1):71-80
Two novel metabolites of benproperine (BPP), 1-[1-methyl-2-[2-(phenylmethyl)phenoxy]ethyl]-3-piperidinol (3-OH-BPP) and 1-[1-methyl-2-[2-(phenylmethyl)phenoxy]ethyl]-4-piperidinol (4-OH-BPP), were confirmed by comparison of retention times and mass spectra with those of synthetic standards using liquid chromatography-tandem mass spectrometry. Selective and sensitive procedures were developed for the simultaneous determination of BPP, 3-OH-BPP and 4-OH-BPP in human plasma and urine. The analytes were extracted from plasma sample and enzymatically hydrolyzed urine samples by liquid-liquid extraction, separated through a Diamonsil C(18) column (150 mm x 4.6 mm i.d.) and determined by tandem mass spectrometry with an electrospray ionization interface in selected reaction monitoring mode. Dextromethorphan was used as internal standard. The mobile phase consisted of acetonitrile-water-formic acid (34:66:1, v/v/v), and flow-rate was 0.5 ml min(-1). This method has a lower limit of quantification (LLOQ) of 60, 4.0 and 4.0 nmol l(-1)for BPP, 3-OH-BPP and 4-OH-BPP in plasma, 4.9, 4.7 and 2.4 nmol l(-1) in urine, respectively. The intra- and inter-run precision were measured to be below 9.2%, and the accuracy was within +/-4.3% for the analytes. The method was successfully used to determine BPP, 3-OH-BPP and 4-OH-BPP in plasma and urine for pharmacokinetic investigation. The results indicated residue of 3-OH-BPP in the body at least 192 h after an oral dose of BPP. 相似文献
4.
Li J Tu ZY Yin JY Yue GX Liu HM 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(22):2107-2112
A rapid, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed for identification of potassium dehydroandrographolidi succinas and its metabolites in rat urine. Five male rats were administrated a single dose (100 mg/kg) of potassium dehydroandrographolidi succinas by i.v. injection. The urine were sampled from 0 to 24 h and purified by using Oasis? HLB extraction cartridge, then the purified urine samples were separated on a reversed-phase C18 column with a linear gradient and detected by an on-line MS detector. Identification and structural elucidation of the metabolites were performed by comparing their changes in molecular mass (Δm) and MS/MS spectra with those of the parent drug. Seven metabolites and the parent drug were found in rat urine. All these metabolites were reported for the first time. 相似文献
5.
Determination of total phthalates in urine by isotope-dilution liquid chromatography-tandem mass spectrometry 总被引:1,自引:0,他引:1
Kato K Silva MJ Needham LL Calafat AM 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,814(2):355-360
Diesters of 1,2-benzenedicarboxylic acid are a family of industrial compounds called "phthalates." The physical and chemical properties of these diesters, and therefore their potential uses, depend on the structure of the dialkyl or alkyl/aryl side chain. The urinary concentrations of phthalate monoesters, which are metabolites, have been used as biomarkers of human exposure to specific phthalates. However, several phthalates, particularly those with side chains of eight or more carbon atoms, are complex mixtures of isomers. For these, the phthalate metabolites to be used as biomarkers of exposure have not been unequivocally identified. We developed a method for assessing total exposure to phthalates, including the isomeric mixtures of high molecular weight phthalates, by measuring the concentration of phthalic acid (PA) in human urine after acid hydrolysis of the phthalate metabolites to PA. The present method accurately assesses total exposure to phthalates without noticeable contamination from the ubiquitous phthalates in the environment, but it gives no information about the parent phthalate. 相似文献
6.
Lv YF Hu X Bi KS 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,852(1-2):35-39
A sensitive and selective analytical method based on liquid chromatography-triple-quadrupole mass spectrometer has been developed to determine mildronate in human plasma and urine. The aim of this work was to find a valid method to study the pharmacokinetic profiles of mildronate in humans. Mildronate is a heart protection medicine, a carnitine's structural analogue, so levocarnitine was used as an internal standard for quantification. Under the electrospray ionization source positive ion mode, calibration curves with good linearities (r=0.9998 for plasma sample and r=0.9999 for urine sample) were obtained in the range of 1.0-20,000 ng ml(-1) for mildronate. The detection limit was 1 ng ml(-1). Recoveries were around 90% for the extraction from human plasma, and good precision and accuracy were achieved. This method is feasible for the evaluation of pharmacokinetic profiles of mildronate in humans, and to the best of our knowledge, this is the first report on LC-MS-MS analysis of mildronate in plasma and urine. 相似文献
7.
Meger M Meger-Kossien I Schuler-Metz A Janket D Scherer G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2002,778(1-2):251-261
A method based on liquid chromatography tandem mass spectrometry (LC-MSMS) applying atmospheric pressure chemical ionisation (APCI) in the positive ion mode was developed for the direct determination of nicotine, cotinine, trans-3'-hydroxycotinine, their corresponding glucuronide conjugates as well as cotinine-N-oxide, norcotinine, and nicotine-N'-oxide in the urine of smokers. The assay involves filtration of crude urine, fast liquid chromatography on a reversed-phase column and mass-specific detection using MSMS transitions. Deuterium-labeled nicotine, cotinine, and trans-3'-hydroxycotinine were used as internal standards. Glucuronides used as reference material were either chemically (cotinine-N-glucuronide) or enzymatically synthesized (nicotine-N-glucuronide and trans-3'-hydroxycotinine-O-glucuronide). Precision for the major nicotine analytes at levels observable in urine of smokers was better than 10%. Accuracy expressed in recovery rates in urine matrix for nicotine, cotinine, trans-3'-hydroxycotinine, and cotinine-N-glucuronide ranged from 87 to 113%. Quantitative results for the three glucuronides in urine samples of 15 smokers were compared to an indirect method in which the aglycons were determined with gas chromatography and nitrogen-selective detection (GC-NPD) before and after enzymatic splitting of the conjugates. Good agreement was found for cotinine-N-glucuronide (coefficient of variation, CV: 9%) and trans-3'-hydroxycotinine-O-glucuronide (CV: 20%), whereas the accordance between both methods was moderate for nicotine-N-glucuronide (CV: 33%). The described LC-MSMS method allows the simultaneous determination of nicotine and eight of its major metabolites in urine of smokers with good precision and accuracy. Since the method requires a minimum of sample clean-up and a very short time for chromatography (3 min), it is suitable for determining the nicotine dose in large-scale human biomonitoring studies. 相似文献
8.
《Biochimica et Biophysica Acta (BBA)/Molecular and Cell Biology of Lipids》2017,1862(8):777-781
Comprehensive quantitative analysis of lipid mediators using liquid chromatography-tandem mass spectrometry is an effective strategy in the elucidation of disease mechanisms; but technically, it has been and is still a great challenge to achieve reliable datasets that cover variety of lipid metabolites contained at trace levels in complex biological matrices. In this opinion article, we introduce our experiences in developing lipid mediator profiling systems, and deliver some comments on limitations of current methodology. 相似文献
9.
Determination of nitrofuran metabolites in poultry muscle and eggs by liquid chromatography-tandem mass spectrometry 总被引:2,自引:0,他引:2
Finzi JK Donato JL Sucupira M De Nucci G 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,824(1-2):30-35
The use of nitrofurans in food-producing animals has been banned in EU. Detection of the protein-bound nitrofuran metabolites is the best approach to evaluate their utilization. A fast, sensitive and reliable LC-MS-MS method is presented to analyze simultaneously the metabolites of four commonly used nitrofuran drugs, furazolidone, furaltadone, nitrofurazone and nitrofurantoin. The sample clean up was performed by a single liquid-liquid extraction step, after a hydrolysis and derivatisation process. Separation of the molecules was performed by liquid chromatography in a C18 column (100 mmx2.1 mm, 4 microm) at room temperature. The quantitative and confirmatory determination of these metabolites was performed by multiple reactions monitoring (MRM). Limits of quantification of 0.5 ngg(-1) were achieved and the total analysis was accomplished in 5 min. This protocol has been applied to identify contaminated samples of poultry muscle and egg products. 相似文献
10.
Vieira-Brock PL Miller EI Nielsen SM Fleckenstein AE Wilkins DG 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(30):3465-3474
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous quantification of nicotine (NIC), cotinine (COT), nornicotine (NNIC), norcotinine (NCOT), nicotine-N-β-D-glucuronide (NIC GLUC), cotinine-N-β-D-glucuronide (COT GLUC), nicotine-1'-oxide (NNO), cotinine-N-oxide (CNO), trans-3'-hydroxycotinine (3-HC), anabasine (AB) and anatabine (AT) was modified and validated for quantification of these selected analytes in rat brain tissue. This analytical method provides support for preclinical NIC pharmacokinetic and toxicological studies after controlled dosing protocols. After brain homogenization and solid-phase extraction, target analytes and corresponding deuterated internal standards were chromatographically separated on a Discovery(?) HS F5 HPLC column with gradient elution and analyzed by LC-MS/MS in positive electrospray ionization (ESI) mode with multiple reaction monitoring (MRM) data acquisition. Method linearity was assessed and calibration curves were determined over the following ranges: 0.1-7.5 ng/mg for NIC, COT GLUC and AB; and 0.025-7.5 ng/mg for COT, NNIC, NCOT, NIC GLUC, NNO, CNO, 3-HC and AT (R(2)≥0.99 for all analytes). Extraction recoveries ranged from 64% to 115%, LC-MS/MS matrix effects were ≤21%, and overall process efficiency ranged from 57% to 93% at low and high quality control concentrations. Intra- and inter-assay imprecisions and accuracy for all analytes were ≤12.9% and ≥86%, respectively. The method was successfully applied to quantification of NIC and metabolites in the brain of post-natal day 90 rats that were sacrificed 2-h after a single 0.8 mg/kg s.c. administration of (-)NIC. In these tissues, striatal concentrations were 204.8±49.4, 138.2±14.2 and 36.1±6.1 pg/mg of NIC, COT and NNIC, respectively. Concentrations of NIC, COT and NNIC in the remaining whole brain (RWhB) were 183.3±68.0, 130.0±14.1 and 46.7±10.3 pg/mg, respectively. Quantification of these same analytes in plasma was also performed by a previously validated method. NIC, COT, NNIC, NCOT, NNO and CNO were detected in plasma with concentrations comparable to those reported in previous studies. However, and in contrast to brain tissues, COT concentrations in plasma were significantly higher than were those of NIC (194.6±18.6 ng/mL versus 52.7±12.9 ng/mL). Taken together, these results demonstrate that a sensitive and selective method has been developed for the determination of NIC biomarkers in rat brain. 相似文献
11.
Zhang X Yang L Zhai S Duan J 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,875(2):349-357
A simple, sensitive and specific HPLC method with tandem mass spectrometry (HPLC/MS/MS) detection has been developed and validated for the simultaneous quantification of tiloronoxim and its major active metabolite, tilorone, in human urine. The analytes, together with metoprolol, which was employed as an internal standard (IS), were extracted with a mixture solvent of chloroform/ethyl ether (1/2, v/v). The chromatographic separation was performed on a narrow-bore reversed phase HPLC column with a gradient mobile phase of methanol/water containing 15 mM ammonium bicarbonate (pH 10.5). The API 3,000 mass spectrometer was equipped with a TurboIonSpray interface and was operated on positive-ion, multiple reaction-monitoring (MRM) mode. The mass transitions monitored were m/z 426.3-->100.0, m/z 411.3-->100.0 and m/z 268.3-->116.1 for tiloronoxim, tilorone and the IS, respectively. The assay exhibited a linear dynamic range of 1-100 ng/ml for both tiloronoxim and tilorone based on the analysis of 0.2 ml aliquots of urine. The lower limit of quantification was 1 ng/ml for both compounds. Acceptable precision and accuracies were obtained for concentrations over the standard curve ranges. Run time of 8 min for each injection made it possible to analyze a high throughput of urine samples. The assay has been successfully used to analyze human urine samples from healthy volunteers. 相似文献
12.
Pan RN Lin CC Huang PW Hsiong CH Pao LH 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2008,872(1-2):58-62
A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of triazolam and its metabolites, alpha-hydroxytriazolam (alpha-OHTRZ) and 4-hydroxytriazolam (4-OHTRZ), was developed and validated. Triazolam-D4 was used as the internal standard (IS). This analysis was carried out on a Thermo((R)) C(18) column and the mobile phase was composed of acetonitrile:H(2)O:formic acid (35:65:0.2, v/v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer using positive ion mode electrospray ionization (ESI) and quantification was performed by multiple reaction monitoring (MRM) mode. The MS/MS ion transitions monitored were m/z 343.1-->308.3, 359.0-->308.3, 359.0-->111.2 and 347.0-->312.0 for triazolam, alpha-OHTRZ, 4-OHTRZ and triazolam-D4, respectively. LLOQ of the analytical method was 0.05ng/mL for triazolam and 0.1ng/mL for alpha-OHTRZ and 4-OHTRZ. The within- and between-run precisions were less than 15.26% and accuracy was -8.08% to 13.33%. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of triazolam in healthy Chinese volunteers. 相似文献
13.
Zhang JY Fast DM Breau AP 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,785(1):123-134
A simple, sensitive and specific automated SPE-LC-MS-MS assay was developed and validated for determination of valdecoxib (I), its hydroxylated metabolite (II) and carboxylic acid metabolite (III) in human urine. The analytes (I, II and III) and a structural analogue internal standard (I.S.) were extracted on a C(18) solid-phase extraction cartridge using a Zymark RapidTrace automation system. The chromatographic separation was performed on a narrow-bore reverse phase HPLC column with a mobile phase of acetonitrile-water (50:50, v/v) containing 10 mM 4-methylmorpholine (pH 6.0). The analytes were ionized using negative electrospray mass spectrometry, then detected by multiple reaction monitoring with a tandem mass spectrometer. The precursor to product ion transitions of m/z 313-->118, m/z 329-->196 and m/z 343-->196 were used to measure I, II and III, respectively. The assay exhibited a linear dynamic range of 1-200 ng/ml for I and II and 2-200 ng/ml for III in human urine. The lower limit of quantitation was 1 ng/ml for I and II and 2 ng/ml for III. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. Run time of 5.5 min for each sample made it possible to analyze a throughput of 70 human urine samples per run. The assay has been successfully used to analyze human urine samples to support clinical phase I and II studies. 相似文献
14.
Leung GN Chung EW Ho EN Kwok WH Leung DK Tang FP Wan TS Yu NH 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2005,825(1):47-56
This paper describes two high-throughput liquid chromatography-tandem mass spectrometry (LC-MS-MS) methods for the screening of two important classes of drugs in equine sports, namely corticosteroids and basic drugs, at low ppb levels in horse urine. The method utilized a high efficiency reversed-phase LC column (3.3 cm L x 2.1 mm i.d. with 3 microm particles) to provide fast turnaround times. The overall turnaround time for the corticosteroid screen was 5 min and that for the basic drug screen was 8 min, inclusive of post-run and equilibration times. Method specificity was assessed by analysing a total of 35 negative post-race horse urine samples. No interference from the matrices at the expected retention times of the targeted masses was observed. Inter-day precision for the screening of 19 corticosteroids and 48 basic drugs were evaluated by replicate analyses (n = 10) of a spiked sample on 4 consecutive days. The results demonstrated that both methods have acceptable precision to be used on a routine basis. The performance of these two methods on real samples was demonstrated by their applications to drug administration and positive post-race urine samples. 相似文献
15.
Deroussent A Rodriguez S Martelli S Seck A Dubus-Daudigeos E Desmaële D Vassal G Paci A 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(11-12):743-750
Among antitumor oxazaphosphorine drugs, the prodrug ifosfamide (IFO) and its analogs require metabolic activation by specific liver cytochrome P450 (CYP) enzymes to become therapeutically active. New 7,9-dimethyl-ifosfamide analogs have shown greater cytotoxic activity than IFO, whereas side-chain oxidation still occurred leading to monochloroacetone after N-dechloropropylation. A sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed and validated for the simultaneous quantitation of the prodrug 7S,9S-dimethyl-ifosfamide (diMeIFO) and its two inactive metabolites, N(2)- and N(3)-deschloropropyl-dimethylifosfamide (N(2)-DCP-diMeIFO and N(3)-DCP-diMeIFO) in mouse plasma. After protein precipitation with methanol, the analytes were separated by isocratic reversed-phase chromatography with (methanol/ammonium formate pH 5.5, 60:40, v/v) and detected by tandem mass spectrometry using multiple reaction monitoring of transitions ions m/z 289→168 for diMeIFO, m/z 213→168 for N(2)-DCP-diMeIFO, m/z 213→92 for N(3)-DCP-diMeIFO and m/z 261→154 for IFO (internal standard). The calibration curves were linear over the concentration range of 20-10,000ng/mL for the three analytes. Mean extraction recoveries from mouse plasma were 99, 96, 99 and 100% for diMeIFO, N(2)-DCP-diMeIFO, N(3)-DCP-diMeIFO and IFO, respectively. The lower limit of quantitation for diMeIFO and its metabolites was 20 ng/mL in 50 μL plasma. The method was accurate with calculated bias from -5.8 to 4.0% for diMeIFO, from -1.1 to 10.6% for N(2)-DCP-diMeIFO and from -6.9 to 9.8% for N(3)-DCP-diMeIFO, and precise with coefficients of variation lower than 6.8%, 7.8% and 14.3%, respectively. The assay was successfully applied to a preliminary pharmacokinetic study of diMeIFO and of its metabolites in mice. 相似文献
16.
Trdan T Roškar R Trontelj J Ravnikar M Mrhar A 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(23):2323-2331
A selective, sensitive, accurate and precise liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determination of raloxifene and its three glucuronides: raloxifene-6-β-glucuronide (M1), raloxifene-4'-β-glucuronide (M2), raloxifene-6,4'-diglucuronide (M3) in urine samples is presented in this paper. To our knowledge the developed analytical method is the first fully validated method capable of simultaneous determination of raloxifene and its glucuronides in real urine samples. Moreover, for the first time a method for determination of raloxifene diglucuronide in relevant biological samples was introduced. Metabolites were obtained by a bioconversion process of raloxifene to its glucuronides using the microorganism Streptomyces sp. and were used as standards for validation. Urine samples were introduced to a simple solid phase extraction prior to the analysis by LC-MS/MS. The method was linear in a wide range with high determination coefficient (r(2) > 0.997). The limits of quantification achieved were 1.01, 1.95, 2.83 and 4.69 nM for raloxifene, M1, M2 and M3, respectively. The recoveries were higher than 92.5%, the accuracy was within 100 ± 8.8% and the precision was better than 12% for all compounds. The developed method was successfully applied to the real urine samples and showed to be appropriate for use in further research of still not completely discovered raloxifene pharmacokinetics. Furthermore, the presented method could also serve for a potential application in anti-doping analysis. 相似文献
17.
Wang H Jiang J Hu P 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2006,834(1-2):155-162
A fast and selective HPLC-MS-MS method was established to determine L-threonate in human plasma and urine. Plasma and urine samples were extracted by protein precipitation and diluted with water, then chromatographed on an YMC J'Sphere C(18) column with methanol-acetonitrile-10mM ammonium acetate (20:5:75, v/v) as mobile phase, and at a flow rate of 0.2 ml/min. Detection was performed on a triple-quadrupole tandem mass spectrometer using negative electrospray ionization (ESI). Multiple reactions monitoring (MRM) was used and L-threonate was quantified by monitoring the ion transition of m/z 134.5-->74.7. The linear calibration curves of L-threonate in plasma and urine were obtained over the concentration range of 0.25-50 microg/ml and 2.5-500 microg/ml, respectively. Lower limit of quantitation was 0.25 and 2.5 microg/ml, respectively. Accuracy was within 85-115%, and intra- and inter-batch precision (R.S.D.%) were within +/-15%. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of L-threonate in Chinese healthy subjects. 相似文献
18.
Bishop AM Fernandez C Whitehead RD Morales-A P Barr DB Wilder LC Baker SE 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2011,879(20):1823-1826
We developed a selective method to measure riboflavin in human urine. Sample preparation involved solid phase extraction and concentration of the target analyte in urine. The urine concentrate was analyzed using high performance liquid chromatography-tandem mass spectrometry. Riboflavin concentrations were quantified using an isotopically labeled internal standard. The limit of detection was 11 ng/mL, and the linear range was 4.4-20,000 ng/mL. The relative standard deviation at 100, 1000, and 5000 ng/mL was 17%, 17%, and 12%, respectively. The accuracy was 90%. On average, 100 samples, including calibration standards and quality control samples, were prepared per day. Using our method, we measured concentrations of riboflavin in human urine samples that were collected from participants in a study where riboflavin was used as a surrogate chemical to simulate exposure to an environmental toxicant. 相似文献
19.
Hong X Long G Jia H Anqing L Danzhou T 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2007,852(1-2):529-533
A liquid chromatographic (LC)-tandem mass spectrometry (MS/MS) method was developed for simultaneous determination of stilbenes, diethylstilbestrol (DES), hexestrol (HEX), and dienoestrol (DEN) in animal tissue. Sample clean-up and analyte enrichment was performed by automated solid-phase extraction (ASPE) with a silica gel cartridge. Detection capabilities (CCbeta) related to the transition products of lowest abundance for the method were 0.04-0.45 ng g(-1) in tissue and were achieved using atmospheric pressure chemical ionization (APCI) in negative mode. The use of an internal standard in combination with the simplified sample preparation led to a sensitive and reliable analytical method. The recovery level of the method was 84-108% for DES and DEN between 0.5 and 5 ng g(-1), and 59-87% for HEX between 0.25 and 2.5 ng g(-1). 相似文献
20.
Determination of three phthalate metabolites in human urine using on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry 总被引:2,自引:0,他引:2
Kato K Shoda S Takahashi M Doi N Yoshimura Y Nakazawa H 《Journal of chromatography. B, Analytical technologies in the biomedical and life sciences》2003,788(2):407-411
An on-line solid-phase extraction-liquid chromatography-tandem mass spectrometry (on-line SPE-HPLC-MS/MS) method was developed for the analysis of metabolites of three phthalate esters in human urine at the low nanogram per milliliter level. The recoveries were above 84.3% and relative standard deviations varied from 0.8 to 4.8%. The compounds along with their deuterated internal standards were detected in the negative ion mode by selective reaction monitoring and the accuracy of the method was improved by isotope dilution. Monobutyl phthalate was detected with median level of 22.5 ng/ml. The median levels for monobenzyl phthalate and monoethylhexyl phthalate were less than the limit of quantitation (LOQ). The on-line SPE-HPLC-MS/MS method allowed the possibility of determining these metabolites within a short time, with increased sensitivity and by using decreased amounts of sample and solvent. 相似文献