首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A novel, MS-based approach for the relative quantification of proteins, relying on the derivatization of primary amino groups in intact proteins using isobaric tag for relative and absolute quantitation (iTRAQ) is presented. Due to the isobaric mass design of the iTRAQ reagents, differentially labeled proteins do not differ in mass; accordingly, their corresponding proteolytic peptides appear as single peaks in MS scans. Because quantitative information is provided by isotope-encoded reporter ions that can only be observed in MS/MS spectra, we analyzed the fragmentation behavior of ESI and MALDI ions of peptides generated from iTRAQ-labeled proteins using a TOF/TOF and/or a QTOF instrument. We observed efficient liberation of reporter ions for singly protonated peptides at low-energy collision conditions. In contrast, increased collision energies were required to liberate the iTRAQ label from lysine side chains of doubly charged peptides and, thus, to observe reporter ions suitable for relative quantification of proteins with high accuracy. We then developed a quantitative strategy that comprises labeling of intact proteins by iTRAQ followed by gel electrophoresis and peptide MS/MS analyses. As proof of principle, mixtures of five different proteins in various concentration ratios were quantified, demonstrating the general applicability of the approach presented here to quantitative MS-based proteomics.  相似文献   

2.
Gu S  Wang T  Chen X 《Proteomics》2008,8(15):3061-3070
Polymorphisms at toll-like receptor 4 (TLR4) gene have been found to be associated with immune disorders. A murine macrophage cell line GG2EE derived from C3H/HeJ mice with a polymorphism site at TLR4 is hyposensitive to lipopolysaccharide (LPS). To study the molecular base of diverse TLR4-mediated immune responses, the proteomic changes in both TLR4-deficient and wild-type cell lines in response to the same LPS challenge were quantitatively compared by using multiplex amino acid coded mass tagging (AACT)/SILAC-assisted MS. This strategy allows encoding of two distinct cell populations with different stable isotope-tagged lysine residues as the "in-spectra" quantitative markers. In MS analysis of tryptic peptides derived from the equally mixed three cell populations, the lysine-containing peptides originated from two LPS-stimulated cell populations can be clearly distinguished by their different mass shifts from the unstimulated and unlabeled counterpart. The LPS-induced differential protein expression in TLR4-deficient and wild-type proteomes were obtained by comparing the intensities of isotopically encoded peptides. Among the more than 900 proteins identified, 35 were found to be deregulated at different levels in these two cell lines stimulated by LPS. This multiplex mass-tagging methodology can be readily extended to other comparative proteomic quantitation of different cell populations.  相似文献   

3.
4.
Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS) has been recently used to identify disease markers by directly profiling and quantifying the peptide/proteins in biological samples under different physiological or experimental conditions. The information of reproducibility of such quantitative profiling method has not been available. It is important to evaluate and reduce error from technical variation. In this study, an unbiased signal acquisition strategy was used to evaluate the effects of three sample-matrix spotting methods and two matrix chemicals, α-cyano-4-hydroxycinnamic acid (CHCA) and sinapinic acid, on the reproducibility of the peptide/protein signal intensities. The sandwich spotting method using 0.1% nitrocellulose coating film and CHCA gave the best quantitative results for the standard peptides and proteins with mass<66.5 kDa. The normalized signal intensities of the standard peptides and proteins were directly proportional to their concentrations with intra-assay (within-day) coefficient of variations (CVs) ranging from 6.5% to 17%. When analyzing serum peptides <6000 m/z, the interassay (between-days) CVs of all the evaluated peptide peaks were <15%. These data indicate that with the right MS analysis conditions, MALDI-TOF MS appears to be a feasible tool for directly profiling and quantifying the peptide/ proteins in biological samples.  相似文献   

5.
MOTIVATION: Peptide identification following tandem mass spectrometry (MS/MS) is usually achieved by searching for the best match between the mass spectrum of an unidentified peptide and model spectra generated from peptides in a sequence database. This methodology will be successful only if the peptide under investigation belongs to an available database. Our objective is to develop and test the performance of a heuristic optimization algorithm capable of dealing with some features commonly found in actual MS/MS spectra that tend to stop simpler deterministic solution approaches. RESULTS: We present the implementation of a Genetic Algorithm (GA) in the reconstruction of amino acid sequences using only spectral features, discuss some of the problems associated with this approach and compare its performance to a de novo sequencing method. The GA can potentially overcome some of the most problematic aspects associated with de novo analysis of real MS/MS data such as missing or unclearly defined peaks and may prove to be a valuable tool in the proteomics field. We assess the performance of our algorithm under conditions of perfect spectral information, in situations where key spectral features are missing, and using real MS/MS spectral data.  相似文献   

6.
Metabolic labeling techniques have recently become popular tools for the quantitative profiling of proteomes. Classical stable isotope labeling with amino acids in cell cultures (SILAC) uses pairs of heavy/light isotopic forms of amino acids to introduce predictable mass differences in protein samples to be compared. After proteolysis, pairs of cognate precursor peptides can be correlated, and their intensities can be used for mass spectrometry-based relative protein quantification. We present an alternative SILAC approach by which two cell cultures are grown in media containing isobaric forms of amino acids, labeled either with 13C on the carbonyl (C-1) carbon or 15N on backbone nitrogen. Labeled peptides from both samples have the same nominal mass and nearly identical MS/MS spectra but generate upon fragmentation distinct immonium ions separated by 1 amu. When labeled protein samples are mixed, the intensities of these immonium ions can be used for the relative quantification of the parent proteins. We validated the labeling of cellular proteins with valine, isoleucine, and leucine with coverage of 97% of all tryptic peptides. We improved the sensitivity for the detection of the quantification ions on a pulsing instrument by using a specific fast scan event. The analysis of a protein mixture with a known heavy/light ratio showed reliable quantification. Finally the application of the technique to the analysis of two melanoma cell lines yielded quantitative data consistent with those obtained by a classical two-dimensional DIGE analysis of the same samples. Our method combines the features of the SILAC technique with the advantages of isobaric labeling schemes like iTRAQ. We discuss advantages and disadvantages of isobaric SILAC with immonium ion splitting as well as possible ways to improve it.  相似文献   

7.
Applications of affinity chromatography in proteomics   总被引:7,自引:0,他引:7  
Affinity chromatography is a powerful protein separation method that is based on the specific interaction between immobilized ligands and target proteins. Peptides can also be separated effectively by affinity chromatography through the use of peptide-specific ligands. Both two-dimensional electrophoresis (2-DE)- and non-2-DE-based proteomic approaches benefit from the application of affinity chromatography. Before protein separation by 2-DE, affinity separation is used primarily for preconcentration and pretreatment of samples. Those applications entail the removal of one protein or a class of proteins that might interfere with 2-DE resolution, the concentration of low-abundance proteins to enable them to be visualized in the gel, and the classification of total protein into two or more groups for further separation by gel electrophoresis. Non-2-DE-based approaches have extensively employed affinity chromatography to reduce the complexity of protein and peptide mixtures. Prior to mass spectrometry (MS), preconcentration and capture of specific proteins or peptides to enhance sensitivity can be accomplished by using affinity adsorption. Affinity purification of protein complexes followed by identification of proteins by MS serves as a powerful tool for generating a map of protein-protein interactions and cellular locations of complexes. Affinity chromatography of peptide mixtures, coupled with mass spectrometry, provides a tool for the study of protein posttranslational modification (PTM) sites and quantitative proteomics. Quantitation of proteomes is possible via the use of isotope-coded affinity tags and isolation of proteolytic peptides by affinity chromatography. An emerging area of proteomics technology development is miniaturization. Affinity chromatography is becoming more widely used for exploring PTM and protein-protein interactions, especially with a view toward developing new general tag systems and strategies of chemical derivatization on peptides for affinity selection. More applications of affinity-based purification can be expected, including increasing the resolution in 2-DE, improving the sensitivity of MS quantification, and incorporating purification as part of multidimensional liquid chromatography experiments.  相似文献   

8.
Post-translational modifications (PTMs) play key roles in the regulation of biological functions of proteins. Although some progress has been made in identifying several PTMs using existing approaches involving a combination of affinity-based enrichment and mass spectrometric analysis, comprehensive identification of PTMs remains a challenging problem in proteomics because of the dynamic complexities of PTMs in vivo and their low abundance. We describe here a strategy for rapid, efficient, and comprehensive identification of PTMs occurring in biological processes in vivo. It involves a selectively excluded mass screening analysis (SEMSA) of unmodified peptides during liquid chromatography-electrospray ionization-quadrupole-time-of-flight tandem mass spectrometry (LC-ESI-q-TOF MS/MS) through replicated runs of a purified protein on two-dimensional gel. A precursor ion list of unmodified peptides with high mass intensities was obtained during the initial run followed by exclusion of these unmodified peptides in subsequent runs. The exclusion list can grow as long as replicate runs are iteratively performed. This enables the identifications of modified peptides with precursor ions of low intensities by MS/MS sequencing. Application of this approach in combination with the PTM search algorithm MODi to GAPDH protein in vivo modified by oxidative stress provides information on multiple protein modifications (19 types of modification on 42 sites) with >92% peptide coverage and the additional potential for finding novel modifications, such as transformation of Cys to Ser. On the basis of the information of precursor ion m/z, quantitative analysis of PTM was performed for identifying molecular changes in heterogeneous protein populations. Our results show that PTMs in mammalian systems in vivo are more complicated and heterogeneous than previously reported. We believe that this strategy has significant potential because it permits systematic characterization of multiple PTMs in functional proteomics.  相似文献   

9.
Progress in understanding the biosynthetic pathway of the cyclotides has been hampered as this unique family of cyclic plant peptides are notoriously difficult to analyse by standard proteomic approaches such as gel electrophoresis. We have developed a simple, rapid and robust strategy for the quantification of cyclotides in crude plant extracts using MALDI-TOF MS making use of generic peptides similar in mass to the analyte as internal standards for calibration. Linearity (r(2)>0.99) over two orders of magnitude (down to femtomole levels) was achieved in plant extracts, allowing quantitative analysis of transgenic and endogenous peptide expression.  相似文献   

10.
Verification of candidate biomarker proteins in blood is typically done using multiple reaction monitoring (MRM) of peptides by LC-MS/MS on triple quadrupole MS systems. MRM assay development for each protein requires significant time and cost, much of which is likely to be of little value if the candidate biomarker is below the detection limit in blood or a false positive in the original discovery data. Here we present a new technology, accurate inclusion mass screening (AIMS), designed to provide a bridge from unbiased discovery to MS-based targeted assay development. Masses on the software inclusion list are monitored in each scan on the Orbitrap MS system, and MS/MS spectra for sequence confirmation are acquired only when a peptide from the list is detected with both the correct accurate mass and charge state. The AIMS experiment confirms that a given peptide (and thus the protein from which it is derived) is present in the plasma. Throughput of the method is sufficient to qualify up to a hundred proteins/week. The sensitivity of AIMS is similar to MRM on a triple quadrupole MS system using optimized sample preparation methods (low tens of ng/ml in plasma), and MS/MS data from the AIMS experiments on the Orbitrap can be directly used to configure MRM assays. The method was shown to be at least 4-fold more efficient at detecting peptides of interest than undirected LC-MS/MS experiments using the same instrumentation, and relative quantitation information can be obtained by AIMS in case versus control experiments. Detection by AIMS ensures that a quantitative MRM-based assay can be configured for that protein. The method has the potential to qualify large number of biomarker candidates based on their detection in plasma prior to committing to the time- and resource-intensive steps of establishing a quantitative assay.  相似文献   

11.
Over the past two decades, mass spectrometry (MS) has emerged as a bone fide approach for structural biology. MS can inform on all levels of protein organization, and enables quantitative assessments of their intrinsic dynamics. The key advantages of MS are that it is a sensitive, high-resolution separation technique with wide applicability, and thereby allows the interrogation of transient protein assemblies in the context of complex mixtures. Here we describe how molecular-level information is derived from MS experiments, and how it can be combined with spatial and dynamical restraints obtained from other structural biology approaches to allow hybrid studies of protein architecture and movements.  相似文献   

12.
Characterisation of blood serum peptides can provide valuable information on physiological and pathological processes. However, the analysis of raw serum samples by MS results in the identification of a limited number of peptides. In order to improve sensitivity, many peptide enrichment methods have been proposed during the last ten years. Here, we present a comparison of fractionation methods aimed to simplify analysis of small proteins and peptides in blood serum, one of the most promising sources of putative biomarkers. Specifically, three methods based on ultrafiltration, differential precipitation, and peptide ligand libraries (ProteoMiner) were evaluated for the enrichment of peptides and low molecular weight proteins, as demonstrated by Tricine SDS-PAGE and subsequent LC-MS/MS (GeLC-MS/MS). As a result, differential solubilisation (DS) allowed the identification of the highest number of peptides. Moreover, the DS method enabled also the quantitative comparison of samples, producing fundamental information in biomarker discovery approaches.  相似文献   

13.
The main goal of many proteomics experiments is an accurate and rapid quantification and identification of regulated proteins in complex biological samples. The bottleneck in quantitative proteomics remains the availability of efficient software to evaluate and quantify the tremendous amount of mass spectral data acquired during a proteomics project. A new software suite, ICPLQuant, has been developed to accurately quantify isotope‐coded protein label (ICPL)‐labeled peptides on the MS level during LC‐MALDI and peptide mass fingerprint experiments. The tool is able to generate a list of differentially regulated peptide precursors for subsequent MS/MS experiments, minimizing time‐consuming acquisition and interpretation of MS/MS data. ICPLQuant is based on two independent units. Unit 1 performs ICPL multiplex detection and quantification and proposes peptides to be identified by MS/MS. Unit 2 combines MASCOT MS/MS protein identification with the quantitative data and produces a protein/peptide list with all the relevant information accessible for further data mining. The accuracy of quantification, selection of peptides for MS/MS‐identification and the automated output of a protein list of regulated proteins are demonstrated by the comparative analysis of four different mixtures of three proteins (Ovalbumin, Horseradish Peroxidase and Rabbit Albumin) spiked into the complex protein background of the DGPF Proteome Marker.  相似文献   

14.
Analysing proteomic data   总被引:5,自引:0,他引:5  
The rapid growth of proteomics has been made possible by the development of reproducible 2D gels and biological mass spectrometry. However, despite technical improvements 2D gels are still less than perfectly reproducible and gels have to be aligned so spots for identical proteins appear in the same place. Gels can be warped by a variety of techniques to make them concordant. When gels are manipulated to improve registration, information is lost, so direct methods for gel registration which make use of all available data for spot matching are preferable to indirect ones. In order to identify proteins from gel spots a property or combination of properties that are unique to that protein are required. These can then be used to search databases for possible matches. Molecular mass, pI, amino acid composition and short sequence tags can all be used in database searches. Currently the method of choice for protein identification is mass spectrometry. Proteins are eluted from the gels and cleaved with specific endoproteases to produce a series of peptides of different molecular mass. In peptide mass fingerprinting, the peptide profile of the unknown protein is compared with theoretical peptide libraries generated from sequences in the different databases. Tandem mass spectroscopy (MS/MS) generates short amino acid sequence tags for the individual peptides. These partial sequences combined with the original peptide masses are then used for database searching, greatly improving specificity. Increasingly protein identification from MS/MS data is being fully or partially automated. When working with organisms, which do not have sequenced genomes (the case with most helminths), protein identification by database searching becomes problematical. A number of approaches to cross species protein identification have been suggested, but if the organism being studied is only distantly related to any organism with a sequenced genome then the likelihood of protein identification remains small. The dynamic nature of the proteome means that there really is no such thing as a single representative proteome and a complete set of metadata (data about the data) is going to be required if the full potential of database mining is to be realised in the future.  相似文献   

15.
Yang SJ  Nie AY  Zhang L  Yan GQ  Yao J  Xie LQ  Lu HJ  Yang PY 《Journal of Proteomics》2012,75(18):5797-5806
Quantification by series of b, y fragment ion pairs generated from isobaric-labeled peptides in MS2 spectra has recently been considered an accurate strategy in quantitative proteomics. Here we developed a novel MS2 quantification approach named quantitation by isobaric terminal labeling (QITL) by coupling (18)O labeling with dimethylation. Trypsin-digested peptides were labeled with two (16)O or (18)O atoms at their C-termini in H(2)(16)O or H(2)(18)O. After blocking all ε-amino groups of lysines through guanidination, the N-termini of the peptides were accordingly labeled with formaldehyde-d(2) or formaldehyde. These indistinguishable, isobaric-labeled peptides in MS1 spectra produce b, y fragment ion pairs in the whole mass range of MS2 spectra that can be used for quantification. In this study, the feasibility of QITL was first demonstrated using standard proteins. An accurate and reproducible quantification over a wide dynamic range was achieved. Then, complex rat liver samples were used to verify the applicability of QITL for large-scale quantitative analysis. Finally, QITL was applied to profile the quantitative proteome of hepatocellular carcinoma (HCC) and adjacent non-tumor liver tissues. Given its simplicity, low-cost, and accuracy, QITL can be widely applied in biological samples (cell lines, tissues, and body fluids, etc.) for quantitative proteomic research.  相似文献   

16.
Multiplexed tandem mass spectrometry (MS/MS) has recently been demonstrated as a means to increase the throughput of peptide identification in liquid chromatography (LC) MS/MS experiments. In this approach, a set of parent species is dissociated simultaneously and measured in a single spectrum (in the same manner that a single parent ion is conventionally studied), providing a gain in sensitivity and throughput proportional to the number of species that can be simultaneously addressed. In the present work, simulations performed using the Caenorhabditis elegans predicted proteins database show that multiplexed MS/MS data allow the identification of tryptic peptides from mixtures of up to ten peptides from a single dataset with only three "y" or "b" fragments per peptide and a mass accuracy of 2.5 to 5 ppm. At this level of database and data complexity, 98% of the 500 peptides considered in the simulation were correctly identified. This compares favorably with the rates obtained for classical MS/MS at more modest mass measurement accuracy. LC multiplexed Fourier transform-ion cyclotron resonance MS/MS data obtained from a 66 kDa protein (bovine serum albumin) tryptic digest sample are presented to illustrate the approach, and confirm that peptides can be effectively identified from the C. elegans database to which the protein sequence had been appended.  相似文献   

17.
Comparability studies lie at the heart of assessments that evaluate differences amongst manufacturing processes and stability studies of protein therapeutics. Low resolution chromatographic and electrophoretic methods facilitate quantitation, but do not always yield detailed insight into the effect of the manufacturing change or environmental stress. Conversely, mass spectrometry (MS) can provide high resolution information on the molecule, but conventional methods are not very quantitative. This gap can be reconciled by use of a stable isotope-tagged reference standard (SITRS), a version of the analyte protein that is uniformly labeled with 13C6-arginine and 13C6-lysine. The SITRS serves as an internal control that is trypsin-digested and analyzed by liquid chromatography (LC)-MS with the analyte sample. The ratio of the ion intensities of each unlabeled and labeled peptide pair is then compared to that of other sample(s). A comparison of these ratios provides a readily accessible way to spot even minute differences among samples. In a study of a monoclonal antibody (mAb) spiked with varying amounts of the same antibody bearing point mutations, peptides containing the mutations were readily identified and quantified at concentrations as low as 2% relative to unmodified peptides. The method was robust, reproducible and produced a linear response for every peptide that was monitored. The method was also successfully used to distinguish between two batches of a mAb that were produced in two different cell lines while two batches produced from the same cell line were found to be highly comparable. Finally, the use of the SITRS method in the comparison of two stressed mAb samples enabled the identification of sites susceptible to deamidation and oxidation, as well as their quantitation. The experimental results indicate that use of a SITRS in a peptide mapping experiment with MS detection enables sensitive and quantitative comparability studies of proteins at high resolution.Key words: protein therapeutics, monoclonal antibodies, comparability, peptide mapping, mass spectrometry, LC-MS, stable isotope-tagged reference standard, SITRS  相似文献   

18.
MOTIVATION: Mass spectrometry (MS) data are impaired by noise similar to many other analytical methods. Therefore, proteomics requires statistical approaches to determine the reliability of regulatory information if protein quantification is based on ion intensities observed in MS. RESULTS: We suggest a procedure to model instrument and workflow-specific noise behaviour of iTRAQ reporter ions that can provide regulatory information during automated peptide sequencing by LC-MS/MS. The established mathematical model representatively predicts possible variations of iTRAQ reporter ions in an MS data-dependent manner. The model can be utilized to calculate the robustness of regulatory information systematically at the peptide level in so-called bottom-up proteome approaches. It allows to determine the best fitting regulation factor and in addition to calculate the probability of alternative regulations. The result can be visualized as likelihood curves summarizing both the quantity and quality of regulatory information. Likelihood curves basically can be calculated from all peptides belonging to different regions of proteins if they are detected in LC-MS/MS experiments. Therefore, this approach renders excellent opportunities to detect and statistically validate dynamic post-translational modifications usually affecting only particular regions of the whole protein. The detection of known phosphorylation events at protein kinases served as a first proof of concept in this study and underscores the potential for noise models in quantitative proteomics.  相似文献   

19.
A matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS)-based kinase assay using a peptide substrate tagged with a biotinyl group has been developed. The peptide moiety was designed to serve as an efficient substrate for calcium/calmodulin-dependent protein kinase II, based on the in vivo phosphorylation site of phosrestin I, a Drosophila homolog of arrestin. In the assay, the quantitative relationship was determined from the ratio of the peak areas between the two peaks respectively representing the unphosphorylated and the phosphorylated substrate. Attempts to assay phosphorylated peptides directly from the reaction mixture, gave inaccurate results because of the high noise level caused by the presence of salts and detergents. In contrast, after purifying the substrate peptides with the biotin affinity tag using streptavidin-coated magnetic beads, peak areas accurately represented the ratio between the unphosphorylated and phosphorylated peptide. By changing the substrate peptide to a peptide sequence that serves as a kinase substrate, it is expected that an efficient non-radioactive protein kinase assay using MALDI-TOF MS can be developed for any type of protein kinase. We call this technique "Affinity-Tagged Phosphorylation Assay by MALDI-TOF MS (ATPA-MALDI)." ATPA-MALDI should serve as a quick and efficient non-radioactive protein kinase assay by MALDI-TOF MS.  相似文献   

20.
High mass measurement accuracy is critical for confident protein identification and characterization in proteomics research. Fourier transform ion cyclotron resonance (FTICR) mass spectrometry is a unique technique which can provide unparalleled mass accuracy and resolving power. However, the mass measurement accuracy of FTICR-MS can be affected by space charge effects. Here, we present a novel internal calibrant-free calibration method that corrects for space charge-induced frequency shifts in FTICR fragment spectra called Calibration Optimization on Fragment Ions (COFI). This new strategy utilizes the information from fixed mass differences between two neighboring peptide fragment ions (such as y(1) and y(2)) to correct the frequency shift after data collection. COFI has been successfully applied to LC-FTICR fragmentation data. Mascot MS/MS ion search data demonstrate that most of the fragments from BSA tryptic digested peptides can be identified using a much lower mass tolerance window after applying COFI to LC-FTICR-MS/MS of BSA tryptic digest. Furthermore, COFI has been used for multiplexed LC-CID-FTICR-MS which is an attractive technique because of its increased duty cycle and dynamic range. After the application of COFI to a multiplexed LC-CID-FTICR-MS of BSA tryptic digest, we achieved an average measured mass accuracy of 2.49 ppm for all the identified BSA fragments.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号