首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The quality of MALDI‐TOF mass spectrometric analysis is highly dependent on the matrix and its deposition strategy. Although different matrix‐deposition methods have specific advantages, one major problem in the field of proteomics, particularly with respect to quantitation, is reproducibility between users or laboratories. Compounding this is the varying crystal homogeneity of matrices depending on the deposition strategy used. Here, we describe a novel optimised matrix‐deposition strategy for LC‐MALDI‐TOF/TOF MS using an automated instrument that produces a nebulised matrix “mist” under controlled atmospheric conditions. Comparisons of this with previously reported strategies showed the method to be advantageous for the atypical matrix, 2,5‐DHB, and improved phosphopeptide ionisation when compared with deposition strategies for CHCA. This optimised DHB matrix‐deposition strategy with LC‐MALDI‐TOF/TOF MS, termed EZYprep LC, was subsequently optimised for phosphoproteome analysis and compared to LC‐ESI‐IT‐MS and a previously reported approach for phosphotyrosine identification and characterisation. These methods were used to map phosphorylation on epidermal growth factor‐stimulated epidermal growth factor receptor to gauge the sensitivity of the proposed method. EZYprep DHB LC‐MALDI‐TOF/TOF MS was able to identify more phosphopeptides and characterise more phosphorylation sites than the other two proteomic strategies, thus proving to be a sensitive approach for phosphoproteome analysis.  相似文献   

2.
Phosphorylation is one of the most important PTMs and is estimated to occur on 30% of the mammalian proteome. Its perturbed regulation has been implicated in many pathologies. The rarity of phosphotyrosine compared with phosphoserine or phosphothreonine is prompting the development of more sensitive approaches because proteomic technologies that are currently used to assess tyrosine phosphorylation in proteins are inadequate, identifying only a fraction of the predicted tyrosine phosphoproteome. Here we describe the development of a reproducible, high‐sensitivity methodology for the detection and mapping of phosphotyrosine residues by MS. The anti‐phosphotyrosine antibody 4G10 was coupled covalently to super para‐magnetic beads or by affinity to super para‐magnetic beads with protein G covalently attached. Using this approach, we successfully enriched phosphotyrosine peptides mixed with non‐phosphorylated peptides at a ratio of up to 1:200, enabling detection at a level representing the highest sensitivity reported for tyrosine phosphorylation. The beads were subsequently used to enrich tyrosine phosphopeptides from a digest of the in vitro‐phosphorylated recombinant β‐intracellular region of the granulocyte‐macrophage colony‐stimulating factor receptor, which was subsequently analysed by MALDI‐TOF/TOF MS. Our results define this methodology as a sensitive approach for tyrosine phosphoproteome analysis.  相似文献   

3.
Proteomic profiling by MALDI‐TOF MS presents various advantages (speed of analysis, ease of use, relatively low cost, sensitivity, tolerance against detergents and contaminants, and possibility of automation) and is being currently used in many applications (e.g. peptide/protein identification and quantification, biomarker discovery, and imaging MS). Earlier studies by many groups indicated that moderate reproducibility in relative peptide quantification is a major limitation of MALDI‐TOF MS. In the present work, we examined and demonstrate a clear effect, in cases apparently random, of sample dilution in complex samples (urine) on the relative quantification of peptides by MALDI‐TOF MS. Results indicate that in urine relative abundance of peptides cannot be assessed with confidence based on a single MALDI‐TOF MS spectrum. To account for this issue, we developed and propose a novel method of determining the relative abundance of peptides, taking into account that peptides have individual linear quantification ranges in relation to sample dilution. We developed an algorithm that calculates the range of dilutions at which each peptide responds in a linear manner and normalizes the received peptide intensity values accordingly. This concept was successfully applied to a set of urine samples from patients diagnosed with diabetes presenting normoalbuminuria (controls) and macroalbuminuria (cases).  相似文献   

4.
5.
Herein we report the use of mesoporous aluminosilicate (MPAS) for the simultaneous extraction of peptides and lipids from complex body fluids such as human plasma and synovial fluid. We show that MPAS particles, given their mesostructural features with nanometric pore size and high surface area, are an efficient device for simultaneous extraction of peptidome and lipidome from as little as a few microliters of body fluids. The peptides and the lipids, selected and enriched by MPAS particles and rapidly visualized by MALDI‐TOF MS, could form part of a diagnostic profile of the “peptidome” and the “lipidome” of healthy versus diseased subjects in comparative studies. The ability of this approach to rapidly reveal the overall pattern of changes in both lipidome and peptidome signatures of complex biofluids could be of valuable interest for handling large numbers of samples required in ‐omics studies for the purpose of finding novel biomarkers.  相似文献   

6.
The discovery of novel biomarkers by means of advanced detection tools based on proteomic analysis technologies necessitates the development of improved diagnostic methods for application in clinical routine. On the basis of three different application examples, this review presents the limitations of conventional routine diagnostic assays and illustrates the advantages of immunoaffinity enrichment combined with MALDI‐TOF MS. Applying this approach increases the specificity of the analysis supporting a better diagnostic recognition, sensitivity, and differentiation of certain diseases. The use of MALDI‐TOF MS as detection method facilitates the identification of modified peptides and proteins providing additional information. Further, employing respective internal standard peptides allows for relative and absolute quantitation which is mandatory in the clinical context. Although MALDI‐TOF MS is not yet established for clinical routine diagnostics this technology has a high potential for improvement of clinical diagnostics and monitoring therapeutic efficacy.  相似文献   

7.
8.
9.
10.
11.
12.
In this work, core‐shell magnetic metal organic framework (MOF) microspheres were successfully synthesized by coating magnetite particles with mercaptoacetic acid and subsequent reactions with ethanol solutions of Cu(OAc)2 and benzene‐1,3,5‐tricarboxylic acid (designated as H3btc) alternately. The resulting Fe3O4@[Cu3(btc)2] possess strong magnetic responsiveness. We applied the novel nanocomposites in the enrichment of low‐concentration standard peptides, peptides in MYO and BSA tryptic digests and in human urine in combination with MALDI‐TOF MS analysis for the first time. In addition, the Cu3(btc)2 MOF shells exhibit strong affinity to peptides, thus providing a rapid and convenient approach to the concentration of low‐abundance peptides. Notably, peptides at an extremely low concentration of 10 pM could be detected by MALDI‐TOF MS after enrichment with the magnetic MOF composites. In brief, the facile synthesis and efficient enrichment process of the Fe3O4@[Cu3(btc)2] microspheres make them promising candidates for the isolation of peptides in even complex biological environments.  相似文献   

13.
Sandflies (Diptera: Psychodidae) (Newstead, 1911) are blood‐feeding insects that transmit human pathogens including Leishmania (Trypanosomatida: Trypanosomatidae) parasites, causative agents of the leishmaniases. To elucidate Leishmania transmission cycles, conclusive identification of vector species is essential. Molecular approaches including matrix‐assisted laser desorption ionization time‐of‐flight mass spectrometry (MALDI‐TOF MS) protein profiling have recently emerged to complement morphological identification. The aim of this study was to evaluate the effect of the trap type used to collect sandflies, specifically Centers for Disease Control (CDC) light or sticky traps, the two most commonly used in sandfly surveys, on subsequent MALDI‐TOF MS protein profiling. Specimens of five species (Phlebotomus ariasi, Phlebotomus papatasi, Phlebotomus perniciosus, Phlebotomus sergenti, Sergentomyia minuta) collected in periurban and agricultural habitats in southeast Spain were subjected to protein profiling. Acquired protein spectra were queried against an in‐house reference database and their quality assessed to evaluate the trap type effect. The results indicate that trap choice can substantially affect the quality of protein spectra in collected sandflies. Whereas specimens retrieved from light traps produced intense and reproducible spectra that allowed reliable species determination, profiles of specimens from sticky traps were compromised and often did not enable correct identification. Sticky traps should therefore not be used in surveys that deploy MALDI‐TOF MS protein profiling for species identification.  相似文献   

14.
Mark L. Stolowitz 《Proteomics》2012,12(23-24):3438-3450
Over the course of the last decade, a number of investigators have come to appreciate that the surface of a MALDI target, after suitable modification, can be used for selective enrichment of peptides and proteins. More recently, surface‐modified nanoparticles (NPs) that readily co‐crystallize in MALDI matrix, are not ionized by laser desorption/ionization, and do not interfere with MS have attracted interest as alternatives to surface‐modified targets for selective enrichment of peptides and proteins. Surface‐modified targets and NPs facilitate parallel processing of samples, and when used in conjunction with MALDI mass spectrometers with kHz lasers enable development of high‐throughput proteomics platforms. Targets and NPs for reversed phase and ion exchange retention, selective enrichment of glycopeptides, selective enrichment of phosphopeptides, and immunoaffinity MS are described in conjunction with details regarding their preparation and utility. Commercial availability of the reagents and substrates required to prepare surface‐modified targets and NPs is also discussed.  相似文献   

15.
Ticks and fleas are vectors for numerous human and animal pathogens. Controlling them, which is important in combating such diseases, requires accurate identification, to distinguish between vector and non‐vector species. Recently, matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry (MALDI‐TOF‐MS) was applied to the rapid identification of arthropods. The growth of this promising tool, however, requires guidelines to be established. To this end, standardization protocols were applied to species of Rhipicephalus sanguineus (Ixodida: Ixodidae) Latreille and Ctenocephalides felis felis (Siphonaptera: Pulicidae) Bouché, including the automation of sample homogenization using two homogenizer devices, and varied sample preservation modes for a period of 1–6 months. The MS spectra were then compared with those obtained from manual pestle grinding, the standard homogenization method. Both automated methods generated intense, reproducible MS spectra from fresh specimens. Frozen storage methods appeared to represent the best preservation mode, for up to 6 months, while storage in ethanol is also possible, with some caveats for tick specimens. Carnoy's buffer, however, was shown to be less compatible with MS analysis for the purpose of identifying ticks or fleas. These standard protocols for MALDI‐TOF MS arthropod identification should be complemented by additional MS spectrum quality controls, to generalize their use in monitoring arthropods of medical interest.  相似文献   

16.
Comparison of protein profiles of sera acquired before and after preoperative chemotherapy for breast cancer may reveal tumor markers that could be used to monitor tumor response. In this study, we analyzed pre‐ and post‐chemotherapy protein profiles of sera from 39 HER2‐postive breast cancer patients (n=78 samples) who received 6 months of preoperative chemotherapy using LC‐MALDI‐TOF/MS technology. We detected qualitative and quantitative differences in pair‐wise comparison of pre‐ and post chemotherapy samples that were different in patients who achieved pathological complete response (pCR, n=21) compared with those with residual disease (n=18). We identified 2329 and 3152 peaks as differentially expressed in the pre‐chemotherapy samples of the responders and non‐responders. Comparison of matching pre‐ and post‐chemotherapy samples identified 34 (32 decreased, two increased) and 304 peaks (157 decreased, 147 increased) that significantly changed (p<0.01, false discovery rate ≤20%) after treatment in responders and non‐responders, respectively. The top 11 most significantly altered peptide peaks with the greatest change in intensity were positively identified. These corresponded to eight proteins including α‐2‐macroglobulin, complement 3, hemopexin, and serum amyloid P in the responder group and chains C and A of apolipoprotein A‐I, hemopexin precursor, complement C, and amyloid P component in the non‐responding groups. All proteins decreased after therapy, except chain C apolipoprotein A and hemopexin precursor that increased. These results suggest that changes in serum protein levels occur in response to chemotherapy and these changes partly appear different in patients who are highly sensitive to chemotherapy compared with those with lesser response.  相似文献   

17.
18.
Tear proteomic studies revealed distinct similarities between contact lens wearers and dry eye patients. AMO Complete® multipurpose contact lens cleaning solutions containing taurine seem to have a beneficial effect regarding contact lens induced dry eye. To illuminate the effect of taurine on the tear proteome of contact lens wearers and sicca patients we developed a gel-based RP-RP capillary HPLC–MALDI TOF/TOF MS strategy. Two contact lens wearer groups, one using eye drops containing 0.05% taurine; the other for control physiological NaCl solution were monitored. Also, a third group of sicca patients using taurine solution was studied (N = 4 individuals/group). Tear pools of each group at six time points over 5 weeks were analyzed. In summary 267 tear proteins were identified. We found a protein subset showing a linear taurine response with R2 values ≥ 0.5. Taurine effects were detected predominantly in the contact lens group demonstrated by distinct level decreases. Most protein candidates were related to inflammation. Since levels of these proteins differentiate from those of a healthy non-contact lens wearer reference they are supposed to be involved in contact lens induced dry eye and should be focused on in further studies.  相似文献   

19.
Aims: Vibrio identification by means of traditional microbiological methods is time consuming because of the many biochemical tests that have to be performed to distinguish closely related species. This work aimed at evaluating the use of MALDI‐TOF mass spectrometry for the rapid identification of Vibrio (V.) spp. as an advantageous application to rapidly discriminate the most important Vibrio spp. and distinguish Vibrio spp. from closely related bacterial species like Photobacterium damselae and Grimontia hollisae and other aquatic bacteria like Aeromonas spp. Methods and Results: Starting from sub‐colony amounts of pure cultures grown on agar plates, a very simple sample preparation procedure was established and combined with a rapid and automated measurement protocol that allowed species identification within minutes. Closely related species like Vibrio alginolyticus and Vibrio parahaemolyticus or Vibrio cholerae and Vibrio mimicus could thus be differentiated by defining signatures of species‐identifying biomarker ions (SIBIs). As a reference method for species designation and for determination of relationships between strains with molecular markers, partial rpoB gene sequencing was applied. Conclusions: The MALDI‐TOF MS‐based method as well as the rpoB sequence‐based approach for Vibrio identification described in this study produced comparable classification results. The construction of phylogenetic trees from MALDI‐TOF MS and rpoB sequences revealed a very good congruence of both methods. Significance and Impact of the Study: Our results suggest that whole‐cell MALDI‐TOF MS‐based proteometric characterization represents a powerful tool for rapid and accurate classification and identification of Vibrio spp. and related species.  相似文献   

20.
In this work, for the first time, a novel C60‐functionalized magnetic silica microsphere (designated C60‐f‐MS) was synthesized by radical polymerization of C60 molecules on the surface of magnetic silica microspheres. The resulting C60‐f‐MS microsphere has magnetite core and thin C60 modified silica shell, which endow them with useful magnetic responsivity and surface affinity toward low‐concentration peptides and proteins. As a result of their excellent magnetic property, the synthesized C60‐f‐MS microspheres can be easily separated from sample solution without ultracentrifuge. The C60‐f‐MS microspheres were successfully applied to the enrichment of low‐concentration peptides in tryptic protein digest and human urine via a MALDI‐TOF MS analysis. Moreover, they were demonstrated to have enrichment efficiency for low‐concentration proteins. Due to the novel materials maintaining excellent magnetic properties and admirable adsorption, the process of enrichment and desalting is very fast (only 5 min), convenient and efficient. As it has been demonstrated in the study, newly developed fullerene‐derivatized magnetic silica materials are superior to those already available in the market. The facile and low‐cost synthesis as well as the convenient and efficient enrichment process of the novel C60‐f‐MS microspheres makes it a promising candidate for isolation of low‐concentration peptides and proteins even in complex biological samples such as serum, plasma, and urine or cell lysate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号