1.
Antibodies against Mycoplasma pneumoniae in patients' sera with M. pneumoniae infection were measured by the complement fixation (CF) test and enzyme-linked immunosorbent assay (ELISA). Many patients' sera cross-reacted with heterologous mycoplasmal ELISA antigens such as M. hominis, M. hyorhinis, M. orale, M. pulmonis and M. salivarium. The sera with high CF (CF greater than or equal to 40) titers gave significantly higher ELISA values to M. hyorhinis (P less than 0.001) and M. pulmonis (P less than 0.001), which are not parasitic for humans, than those with low CF (CF less than 20) titer. Human normal immunoglobulin G (human normal IgG) containing 98% or more IgG, prepared from pooled plasma of at least 500 normal human donors, showed ELISA reactions with all mycoplasmal strains used. The nonspecific adsorption of human normal IgG on the surface of plate wells and on medium components which might contaminate mycoplasmal ELISA antigens could be disregarded. These results suggest that cross-reactive antibodies to mycoplasmas exist in human sera, and they affect the results of ELISA for serodiagnosis of M. pneumoniae infection.  相似文献   

2.
An enzyme-linked immunosorbent assay (ELISA) has been developed for the measurement of tetanus antitoxin in human sera as an alternative to the toxin neutralization test in mice, the currently accepted method of assay. The ELISA was found to be simple and quick to perform and required only small amounts of materials. In addition, the assay was found to give reproducible estimates of antitoxin levels and to measure antitoxin at levels as low as 0.01 IU per ml, a sensitivity similar to that of the neutralization test. Furthermore, a comparison of the results of the ELISA and the neutralization test involving 80 human sera, including sera with both high and low antitoxin levels, showed close agreement in antitoxin levels obtained by the two methods. It was concluded that ELISA was an acceptable alternative to the toxin neutralization test in mice for the measurement of tetanus antitoxin levels in human sera.  相似文献   

3.
Three serologic test methods for detection of serum antibodies to mouse thymic virus (MTV) were compared, including enzyme-linked immunosorbent assay (ELISA), complement fixation (CF) test and indirect fluorescent antibody (IFA) test. Serum was collected at regular intervals from CD-1 mice inoculated intraperitoneally with approximately 200 infectious doses of MTV, and from uninoculated mice placed in cages with the inoculated animals. The inoculated mice became MTV antibody-positive by all three assay methods at 15 days post inoculation, while the cage-contacts were seropositive by all methods at 30 days after contact. Although the incidence of positive results was similar by all methods, titers measured by ELISA were substantially higher than those measured by CF and IFA tests. Because MTV can cause persistent infections that adversely affect the suitability of mice for research, it is recommended that testing for antibodies to this virus be performed routinely.  相似文献   

4.
Sixty-one serum samples selected on the basis of reactivity in the complement fixation (CF) and latex agglutination (LA) test, were further examined for sensitivity and specificity by indirect haemagglutination (IHA), enzyme linked immunosorbent assay (ELISA) and defined antigen substrate spheres (DASS). Twenty sera from healthy Europeans and 48 samples from patients with either schistosomiasis or trichinosis were also tested. Comparable levels of sensitivity were found between the CF and LA positive sera and IHA, ELISA and DASS. Of the CF positive LA negative group of sera, many were positive by DASS but only a few reacted in IHA and ELISA. Some cross reactivity was also observed in the schistosomiasis sera tested by IHA and ELISA.  相似文献   

5.
An immunoassay based on stick-type solid support (immunostick assay) was developed. To demonstrate the medical diagnosis of rheumatoid arthritis (RA), cyclic-citrullinated peptide (CCP), one of specific antigens against RA autoantibodies, was immobilized on the surface of the immunostick, and a color index table was prepared for the determination of CCP-positivity of the test sera. The positivity of RA-positive (n = 31) and RA-negative (n = 20) sera was tested using the immunostick assay and a conventional enzyme-linked immunosorbent assay (ELISA). The statistical agreement of the test results from both methods was analyzed using inter-rater coefficient kappa and Bland-Altman test. The immunostick assay with a color index table was determined to have a high statistical correlation to the conventional ELISA method.  相似文献   

6.
The enzyme-linked immunosorbent assay (ELISA) has been used for detection of antibodies against Mycoplasma pneumoniae. The results of ELISA and its sensitivity compared with other serological methods, such as complement fixation (CF), metabolic inhibition (MI), mycoplasmacidal test (MC), and radioimmunoprecipitation (RIP) are reported. ELISA and MC showed greater sensitivity than CF and MI, while RIP showed serum titer two- to 16-fold higher. ELISA was specific as determined using other human mycoplasma. A simplified method based on the determination of ELISA antibody end-point titer by a single serum dilution has been proposed. ELISA presented several advantages: sensitivity, rapidity, and low cost and, if adequately standardized, could become a reliable method for the serodiagnosis of M. pneumoniae infection.  相似文献   

7.
Our laboratory tested water samples used for cooling low-acid canned foods at a canning facility under investigation by the U.S. Food and Drug Administration. We used an enzyme-linked immunosorbent assay with digoxigenin-labeled antibodies (DIG-ELISA) and real-time PCR as screening methods and confirmed the presence of neurotoxin-producing Clostridium botulinum in the samples by mouse bioassay.  相似文献   

8.
A solid-phase enzyme linked immunosorbent assay (ELISA) for determination of IgG antibodies to cytomegalovirus (CMV) is described. The assay used purified CMV and extracts of CMV infected cells as antigen. Antigens were desiccated onto the bottom surface of polystyrene microcuvettes. The antibodies bound to the antigens were assayed by anti-IgG-alkaline phosphate conjugate followed by addition of the enzyme substrate. Titration curves have been obtained from the sera of 35 blood donors and of 23 patients. Comparison of results obtained by ELISA with those obtained by complement fixation (CF) shows that there is agreement between the tests. Both purified CMV and extracts of CMV infected cells were found to be suitable antigens. Purified CMV was of value particularly in those sera which show high reactivity against control antigen. The ELISA technique described is approximately 412 to 548 times more sensitive than the CF test when purified CMV or extracts of CMV infected cells, respectively, are used as antigens. No significant heterotypic rise to CMV was observed by ELISA in three sets of sera with seroconversion to herpes simplex virus. The ELISA technique gives objective results, is easily performed, and may be adaptable as a routine test both for serological diagnosis of CMV infection and for screening of the general population.  相似文献   

9.
The purpose of this study was to prepare recombinant K26 antigen from Leishmania infantum and evaluate its performance by enzyme-linked immunosorbent assay (ELISA) test for serodiagnosis of visceral leishmaniasis (VL) in endemic regions of Iran. The results were compared with those obtained by direct agglutination test (DAT) and whole cell ELISA using crude parasite antigen. Of 93 sera from patients with confirmed VL, 90 sera were positive with rK26 ELISA (sensitivity=96.8%), whereas 85 sera were positive with DAT (sensitivity=91.4%) and 89 sera were positive with whole cell ELISA (sensitivity=95.7%). Of 130 subjects who either had other infectious diseases (n=30) or were healthy (n=100), rK26 ELISA were negative in all cases (specificity=100%), whereas DAT were negative in 116 cases (specificity=89.2%) and whole cell ELISA was negative in 114 cases (specificity=87.7%). The results of this study indicate that the rK26 ELISA is more sensitive and specific than conventional methods and could be used for reliable diagnosis of VL caused by Leishmania infantum.  相似文献   

10.
The etiology of Crohn's disease (CD) is unresolved, but it is likely that an interplay of host genetic factors and environmental triggers is relevant. Mycobacterium paratuberculosis (MAP) has been focused upon as one of these triggers because it causes a similar chronic inflammatory bowel disease in animals. However, the differences among MAP antigens isolated from humans (H-MAP) and cattle (B-MAP) have not been well characterized. In this study, culture filtrate (CF) proteins from MAP isolates were tested with sera from CD patients and healthy controls in enzyme-linked immunosorbent assay (ELISA). Antibody produced by seven CD patients reacted differently according to the antigen source: strong reactivity was seen to H-MAP CF, but not to B-MAP CF. Six proteins, ModD, PepA, transaldolase, EchA9, MAP2120c, and MAP2950c, in H-MAP CF reacting specifically with CD patient sera were identified by liquid chromatography-electrospray ionization-MS. Bioinformatic analysis revealed that ModD and PepA were the same proteins reacting with sera from cattle infected with MAP. The elevated antibody responses of CD patients to rModD and rPepA were confirmed by ELISA ( P <0.001). These results support previous studies showing ModD and PepA as key antigens for the diagnosis of MAP infections. The study also identified additional proteins potentially useful in the design of assays for human MAP infections.  相似文献   

11.
There are several bacterial polysaccharides (PSs) which contain a terminal lipid moiety. It has been postulated that these terminal lipid moieties anchor the PSs to the outer membrane of the bacteria. Our studies have shown that incubation of native PS from group C Neisseria meningitidis or Haemophilus influenzae type b with isolated outer membrane vesicles results in association of a portion of the PS with the vesicles. Removal of the terminal lipid from the PS by treatment with phospholipase A2 or phospholipase D eliminates this association. In other studies, it was shown that delipidated PSs are not suitable as solid-phase antigens in a currently used enzyme-linked immunosorbent assay (ELISA). Measurement of antibody units in the reference sera by using delipidated PSs as antigens in an ELISA yielded negligible absorbance compared with native PSs when methylated human serum albumin was used to coat the PSs to the plate. Nevertheless, phospholipase A2 and phospholipase D treatment did not noticeably affect antigenic epitopes, since soluble group C PS without the terminal lipid bound antibody as effectively as the native PS did, as measured by a competitive inhibition assay. Both hydrophobic and electrostatic interactions are important for the binding of group C N. meningitidis PS to the ELISA plate, while charge interactions seem to be sufficient for binding the more negatively charged H. influenzae type b PS.  相似文献   

12.
An enzyme-linked immunosorbent assay (ELISA) system for hepatitis B e antigen (HBeAg) was developed employing beta-D-galactosidase conjugated with antibody to HBeAg (anti-HBe) and using m-maleimidobenzoyl-N-hydroxysuccinimide ester as the coupling reagent. The experimental conditions for quantitative assay of HBeAg were determined. The presence of rheumatoid factor in test sera did not affect the results. This assay system is more sensitive than the micro-Ouchterlony method and as sensitive as radioimmunoassay. The use of beta-D-galactosidase for ELISA in the field of virology is recommended.  相似文献   

13.
An enzyme-linked immunosorbent assay (ELISA) for detection and quantification of antibodies antiParacoccidioides brasiliensis is described. Polystyrene plates have been used as solid phase to absorb P. brasiliensis metabolic yeast phase antigen. Twenty sera of proven paracoccidioidomycosis, 11 of histoplasmosis due Histoplasma capsulatum, 20 of aspergillosis and 20 human normal sera were tested. Ninety-five percent of the paracoccidioidomycosis sera had O.D. superior to 0.150 (from 0.163 to 2.650) at 1/400 serum dilution. ELISA assay was compared with counterimmunoelectrophoresis and erythro-immunoassay tests; a correlation was observed only with erythro-immunoassay. ELISA test should give new perspectives for the serodiagnosis of paracoccidioidomycosis.  相似文献   

14.
An indirect enzyme-linked immunosorbent assay (ELISA), using cell-associated viral antigen, was developed for detection of antibody to bluetongue virus (BTV) in field-collected pronghorn (Antilocapra americana) sera. To test the applicability of the ELISA to seroepizootiologic studies, pronghorn serum samples from three Wyoming counties (USA) were tested. Bluetongue virus ELISA results were compared to those of the bluetongue immunodiffusion assay. Discrepant serum samples were retested for reaction to either BTV or epizootic hemorrhagic disease virus. The pronghorn BTV ELISA gave rapid, quantitative, objective results and should facilitate testing large numbers of sera for BT diagnostic and seroepizootiologic studies.  相似文献   

15.
A dot-blot enzyme-linked immunosorbent assay (dot-blot ELISA) using an electroeluted 31-kDa glycoprotein from adult worms of Parastrongylus cantonensis as the specific antigen was evaluated for the immunological diagnosis of patients infected with P. cantonensis. The sensitivity and specificity for the detection of serum antibody to P. cantonensis in dot-blot ELISA were both 100%, as determined with serum samples of ten P. cantonensis-infected patients, 60 patients with other related parasitic infections, and 20 uninfected controls. The test was as sensitive and specific as the immunoblot test which revealed a reactive band of 31 kDa. Both the dot-blot ELISA and immunoblot detected all sera from ten P. cantonensis-infected individuals, but not with those of other heterologous parasitoses (gnathostomiasis, toxocariasis, filariasis, paragonimiasis, cysticercosis and malaria) or sera from healthy controls. The dot-blot ELISA is much simpler to perform than the immunoblot technique, and the test can be applied under field conditions where sophisticated facilities are lacking.  相似文献   

16.
A sensitive enzyme-linked immunosorbent assay (ELISA) with rough-surfaced glass beads used as the solid phase was developed for detection of IgG, IgM, and IgA antibodies to Haemophilus influenzae type b capsular polysaccharide (HITB-CP). A successful method for indirect coating of glass bead surfaces with HITB-CP, and parameters affecting the specificity and sensitivity of the assay are described. This ELISA system proved to be 100 times as sensitive as the standard indirect fluorescent-antibody assay. The assay was applied to the measurement of antibodies to HITB-CP in serum and nasal secretions and proved to be a useful tool in the evaluation of immunological response to HITB infection.  相似文献   

17.
Single-serum diagnosis of recent rubella infection was attempted with the use of hemagglutination inhibition (HI) test and two commercially available enzyme-linked immunosorbent assays (ELISAs). The period during which IgM antibody was detectable by IgM capture ELISA was 4 to 30 days after the onset of rash. Rubella IgG ELISA values relative to HI titer were lower in the sera from the patients with recent infection than in the sera from the subjects with remote infection. IgM ELISA and the combined use of IgG ELISA and HI test are two useful methods of single-serum diagnosis of recent rubella infection.  相似文献   

18.
We describe an indirect enzyme-linked immunosorbent assay (ELISA) that utilizes anticanine immunoglobulin for the measurement of rabies-specific antibody in the sera of the major domestic and wildlife reservoirs of rabies in North America. Sufficient cross-reactivity was found to exist between anticanine IgG and serum antibody from all carnivores tested, including dogs, cats, foxes (Vulpes vulpes), skunks (Mephitis sp.) and raccoons (Procyon lotor). With sera of most species, good correlation was observed between results obtained with the ELISA and with the fluorescence inhibition microtest (FIMT). Some wildlife specimens, particularly of skunk and raccoon origin, were cytotoxic in the FIMT, resulting in possible false-positive reactions. In view of this, and since the ELISA is rapid, economical and reproducible (coefficient of variation less than 13%), we consider it to be a favorable alternative to the fluorescence inhibition test for assay of wildlife sera.  相似文献   

19.
Diagnosis of murine infections in relation to test methods employed   总被引:1,自引:0,他引:1  
Comparative investigations of Sendai virus, pneumonia virus of mice (PVM), mouse encephalomyelitis virus (mouse polio), minute virus of mice (MVM), and reovirus type 3 (Reo 3) infected murine colonies revealed a 30% higher incidence of positive sera when enzyme-linked immunosorbent assay (ELISA) was employed instead of hemagglutination inhibition (HI) tests. Equivalent sensitivity as in the ELISA was obtained when the same sera were investigated by indirect immunofluorescence (IF) tests. The virus purification techniques described resulted in highly suitable antigens for all indirect ELISA established. Since IIF requires no purified antigens, this test is recommended as an alternative to ELISA as well as to HI and complement fixation (CF) tests for laboratories lacking the necessary equipment for high speed centrifugation. A high incidence of false positive HI reactions was found particularly in Reo 3 routine serology. An updated survey of seromonitoring showed that European murine colonies appeared to be infected far less with Reo 3 if ELISA or IIF tests were employed. During 1982-1984, only 13% of the mouse colonies screened possessed Reo 3 positive sera whereas no natural Reo 3 infection was found in rat colonies. Mouse hepatitis virus (MHV) and the coronaviruses of rats exhibited the highest incidence in murine colonies. A total of 60% of mouse and 41% of rat colonies were found to be infected by these viruses. In comparison with earlier serological surveys, the relative incidence of other murine infections was similar. Antibodies against Bacillus piliformis (Tyzzer's disease) were detected by the IIF test in 41% of the rat colonies screened.  相似文献   

20.
The passive haemagglutination (PHA) test, enzyme-linked immunosorbent assay (ELISA) and the dot enzyme-immunosorbent assay (DOT-ELISA) were used to detect the levels of IgG antibodies against the Fraction 1 (F1) antigen of Yersinia pestis in sera of plague-infected patients from Northeast Brazil. Twenty three selected PHA-positive sera of subjects with bacteriological confirmation of plague were also positive in the DOT-ELISA but only 19 were detected by the conventional ELISA technique. Another group of 186 serum samples from subjects diagnosed as plague-infected by clinical and epidemiological parameters, but PHA-negative, were screened with DOT-ELISA and 11 gave positive results. The specificity of the assays on the serological detection of plague was confirmed in inhibition tests using purified F1 antigen. These results suggest that DOT-ELISA can be an useful, simple and more sensitive alternative for the serodiagnosis of plague in Northeast Brazil.  相似文献   