首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Microbial infections of medical implants occur in more than 2 million surgical cases each year in the United States alone. These increase patient morbidity and mortality, as well as patient cost and recovery time. Many treatments are available, but none are guaranteed to remove the infection. In many cases, the device infections are caused by the adhesion of microbes to the implant, ensuing growth, pathogenesis, and dissemination. The purpose of this work is to examine the initial events in microbial adhesion by simulating the approach and contact between a planktonic cell, immobilized on an atomic force microscope (AFM) cantilever, and a biomaterial or biofilm substrate. The two model microbes used in this study, Candida parapsilosis (ATCC 90018) and Pseudomonas aeruginosa (ATCC 10145), were chosen for both their clinical relevance and their ease of acquisition and handling in the laboratory setting. Attractive interactions exist between C. parapsilosis and both unmodified silicone rubber and P. aeruginosa biofilms. Using C. parapsilosis cells immobilized on AFM cantilevers with a silicone substrate, we have measured attractive forces of 4.3 +/- 0.25 nN in the approach portion of the force cycle. On P. aeruginosa biofilms, the magnitude of the attractive force decreases to 2.0 +/- 0.40 nN and is preceded by a 2.0-nN repulsion at approximately 75 nm from the cell surface. These data suggest that C. parapsilosis may adhere to both silicone rubber and P. aeruginosa biofilms, possibly contributing to patient morbidity and mortality. Characterization of cell-biomaterial and cell-cell interactions allows for a quantitative link between the physicomechanical and physicochemical properties of implant materials and the nanoscale interactions leading to microbial colonization and infection.  相似文献   

2.
Silicone rubber voice prostheses are implants which are inserted in a non-sterile environment and therefore become quickly colonized by micro-organisms. The micro-organisms exist on the medical grade silicone rubber as mixed biofilms of bacteria and yeasts. A total of 79 bacterial and 39 yeast strains were isolated from these biofilms by soft ultrasonic treatment. Gram-positive/catalase-negative and Gram-positive/catalase-positive cocci represented the dominant bacterial strains. The yeasts were mainly Candida species. Further characterization of cell surface properties such as hydrophobicity by microbial adhesion to hexadecane and electrophoretic mobility showed a distinct difference when the bacterial strains were compared with the yeasts. The bacterial hydrophobicities ranged from 0 to 100% adhesion to hexadecane, whereas the yeast strains, especially the Candida albicans strains, all had markedly hydrophilic cell surfaces. A comparison of the electrophoretic mobilities showed also differences between bacteria and yeast. The values for the bacteria were found to be between -2.5 to -0.5 (10-8 m2 V-1 s-1), whereas for the yeasts electrophoretic mobilities were more positive. Based on the adhesive properties of the isolated micro-organisms, strategies can now be developed to modify the properties of the silicone rubber to reduce biofilm formation on such prostheses.  相似文献   

3.

Laryngectomized patients use indwelling silicone rubber voice prostheses, placed in a surgically created fistula in between the trachea and the esophagus, for voice and speech rehabilitation. At the esophageal side, these voice prostheses rapidly become colonized by a thick biofilm consisting of a variety of oral and skin bacteria and yeasts, and on average, after 3–4 months a prosthesis has to be replaced. In this study, the influence of caffeinated soft drinks on biofilm formation on silicone rubber voice prostheses has been investigated in a modified Robbins device. Robbins devices were first inoculated with the total cultivable microflora from an explanted voice prosthesis for 3 d, after which the devices were perfused three times daily over a 12 day period with 650 ml of either phosphate buffered saline or carbonated mineral water (controls), caffeinated soft drinks (two types), or a decaffeinated and a sugar‐free version of one of the caffeinated soft drinks. At the end of a day, during the experimental period, the devices were filled with growth medium for 30 min. Both caffeinated soft drinks reduced bacterial prevalence in the biofilms to 1–5% of the control, while yeasts thrived in voice prosthetic biofilms exposed to caffeinated soft drinks. Neither the controls, nor the decaffeinated soft drink, nor the sugar‐free version of this showed these effects on bacterial prevalence.  相似文献   

4.
Silicone rubber (SR) is a common soft tissue filler material used in plastic surgery. However, it presents a poor surface for cellular adhesion and suffers from poor biocompatibility. In contrast, hydroxyapatite (HA), a prominent component of animal bone and teeth, can promote improved cell compatibility, but HA is an unsuitable filler material because of the brittleness in mechanism. In this study, using a simple and economical method, two sizes of HA was applied to coat on SR to counteract the poor biocompatibility of SR. Surface and mechanical properties of SR and HA/SRs confirmed that coating with HA changes the surface topology and material properties. Analysis of cell proliferation and adhesion as well as measurement of the expression levels of adhesion related molecules indicated that HA-coated SR significantly increased cell compatibility. Furthermore, mass spectrometry proved that the biocompatibility improvement may be related to elongation factor 1-beta (EF1β)/γ-actin adjusted cytoskeletal rearrangement.  相似文献   

5.
Silicone is a biomaterial that is widely used in many areas because of its high optical clarity, its durability, and the ease with which it can be cast. However, these advantages are counterbalanced by strong hydrophobicity. Gelatin cross-linking has been used as a hydrophilic coating on many biomaterials but not on silicone rubber. In this study, two gelatin glutaraldehyde (GA) cross-linking methods were used to coat a hydrophilic membrane on silicone rubber. In method I, gelatin and GA were mixed in three different proportions (64:1, 128:1, and 256:1) before coating. In method II, a newly formed 5% gelatin membrane was cross-linked with a 2.5% GA solution. All coatings were hydrophilic, as determined from the measurement of contact angle for a drop of water on the surface. Bovine coronary arterial endothelial cells were shown to grow well on the surface modified by method II at 72 h. In method I, the cells grew well for gelatin-GA proportions of 64:1 and 128:1 at 72 h. No cell attachment on untreated silicone rubber was observed by the third d of seeding. The results indicated that both methods of gelatin-GA cross-linking provided a hydrophilic surface on silicone for endothelial cell adhesion and growth in vitro.  相似文献   

6.
Microbial infections of medical implants occur in more than 2 million surgical cases each year in the United States alone. These increase patient morbidity and mortality, as well as patient cost and recovery time. Many treatments are available, but none are guaranteed to remove the infection. In many cases, the device infections are caused by the adhesion of microbes to the implant, ensuing growth, pathogenesis, and dissemination. The purpose of this work is to examine the initial events in microbial adhesion by simulating the approach and contact between a planktonic cell, immobilized on an atomic force microscope (AFM) cantilever, and a biomaterial or biofilm substrate. The two model microbes used in this study, Candida parapsilosis (ATCC 90018) and Pseudomonas aeruginosa (ATCC 10145), were chosen for both their clinical relevance and their ease of acquisition and handling in the laboratory setting. Attractive interactions exist between C. parapsilosis and both unmodified silicone rubber and P. aeruginosa biofilms. Using C. parapsilosis cells immobilized on AFM cantilevers with a silicone substrate, we have measured attractive forces of 4.3 ± 0.25 nN in the approach portion of the force cycle. On P. aeruginosa biofilms, the magnitude of the attractive force decreases to 2.0 ± 0.40 nN and is preceded by a 2.0-nN repulsion at approximately 75 nm from the cell surface. These data suggest that C. parapsilosis may adhere to both silicone rubber and P. aeruginosa biofilms, possibly contributing to patient morbidity and mortality. Characterization of cell-biomaterial and cell-cell interactions allows for a quantitative link between the physicomechanical and physicochemical properties of implant materials and the nanoscale interactions leading to microbial colonization and infection.  相似文献   

7.
目的:从细胞总RNA量的变化观察生物材料有无毒性。方法:将生物材料浸提液作用于成纤维细胞,用异硫氰酸胍一步法抽提细胞总RNA,经RNA电泳和检测和计算其RNA浓度,观察细胞总RNA量的变化。结果:不同的生物材料可引起细胞总RNA量的变化,尤其某种有毒的硅橡胶使细胞总RNA量被严重抑制。结论:观测细胞总RNA量并结合细胞毒性试验及其他分子生物学试验可作为综合评价生物材料分子生物相容性的参考。  相似文献   

8.
Song Y  Zheng Q 《Bioresource technology》2008,99(16):7665-7671
The aim of the present work has been to study the influence of hydrophobic liquids on the morphology and the properties of thermo-molded plastics based on glycerol-plasticized wheat gluten (WG). While the total amount of castor oil and glycerol was remained constant at 30 wt%, castor oil with various proportions with respect to glycerol was incorporated with WG by mixing at room temperature and the resultant mixtures were thermo-molded at 120 degrees C to prepare sheet samples. Moisture absorption, morphology, dynamic mechanical properties, and tensile properties (Young's modulus, tensile strength and elongation at break) of the plastics were evaluated. Experimental results showed that the physical properties of WG plastic were closely related to glycerol to castor oil ratio. Increasing in castor oil content reduces the moisture absorption markedly, which is accompanied with a significant improvement in tensile strength and Young's modulus. These observations were further confirmed in 24 wt% glycerol-plasticized WG plastics containing 6 wt% silicone oil or polydimethylsiloxane (PDMS) liquid rubber.  相似文献   

9.
The long term in vivo biocompatibility is an essential feature for the design and development of sustained drug release carriers. In the recent intraocular drug delivery studies, hydrogels were suggested as sustained release carriers. The biocompatibility test for these hydrogels, however, was commonly performed only through in vitro cell culture examination, which is insufficient before the clinical applications. We compared three thermosensitive hydrogels that have been suggested as the carriers for drugs by their gel-solution phase-change properties. A new block terpolymer (PEOz-PCL-PEOz, ECE) and two commercial products (Matrigel® and Pluronic F127) were studied. The results demonstrated that the ocular media remained translucent for ECE and Pluronic F127 in the first 2 weeks, but cataract formation for Matrigel occurred in 2 weeks and for Pluronic F127 in 1 month, while turbid media was observed for both Matrigel and Pluronic F127 in 2 months. The electrophysiology examinations showed significant neuroretinal toxicity of Matrigel and Pluronic F127 but good biocompatibility of ECE. The neuroretinal toxicity of Matrigel and Pluronic F127 and superior biocompatibility of ECE hydrogel suggests ECE as more appropriate biomaterial for use in research and potentially in intraocular application.  相似文献   

10.
In order to improve the particle erosion resistance of engineering surfaces,this paper proposed a bionic sample which is inspired from the skin structure of desert lizard,Laudakin stoliczkana.The bionic sample consists of a hard shell (aluminum) and a soft core (silicone rubber) which form a two-layer composite structure.The sand blast tests indicated that the bionic sample has better particle erosion resistance.In steady erosion period,the weight loss per unit time of the bionic sample is about 10% smaller than the contrast sample.The anti-erosion mechanism of the bionic sample was studied by single particle impact test.The results show that,after the impact,the kinetic energy of the particle is reduced by 56.5% on the bionic sample which is higher than that on the contrast sample (31.2%).That means the bionic sample can partly convert the kinetic energy of the particle into the deformation energy of the silicone rubber layer,thus the erosion is reduced.  相似文献   

11.
This paper examines the structural and mechanical properties of composite materials based on chitosan and micro- and nanoparticles of Na-montmorillonite and possibility of application for cultivation and targeted delivery of mesenchymal stem cells and regenerative cells. It's have been shown by addition of Na-montmorillonite biomaterial acquires stability of structural and mechanical properties in the sterilization process the handling of liquid media in cell culture. In vitro studies using dermal fibroblasts and adipose tissue mesenchymal stem cells demonstrated that this material has a set of properties to ensure matrix biocompatibility.  相似文献   

12.
几丁聚糖在硅橡胶表面作涂层的实验研究   总被引:3,自引:0,他引:3  
几丁聚糖具有良好的生物相容性和抗菌性,作为生物涂层已经引起了广泛的注意。研究了基体的不同表面处理方法、浸涂次数和几丁聚糖溶液浓度对涂层的表面形貌、结合强度等性能的影响,结果显示,几丁聚糖溶液浓度和硅橡胶表面粗糙度都存在一个最佳取值范围;增加浸涂次数可以改善涂层光洁度,但是对涂层附着力贡献不大;硅橡胶经紫外照射后可以改善几丁聚糖在其上的成膜性能。  相似文献   

13.
We have established a simple flow chamber-based procedure which provides an accurate and reproducible way to measure the amount of biofilm formed on an implantable biomaterial surface. The method enables the side-by-side evaluation of different materials under hydrodynamic flow conditions similar to those found on an implanted device. We have used the method to evaluate the biofilm forming capacity of clinically isolated Escherichia coli on silicone rubber and on silicone rubber containing a hydrophilic coating. It was found that the surface chemistry influenced the colonization of the isolates very differently. In addition, the temperature was found to have a considerable influence upon the adhesion and biofilm forming capacity of some of the isolates, and that the influence of surface chemistry depended on temperature. Our results suggest that the step from using E. coli laboratory strains to clinical isolates entails a significant rise in complexity and yields results that cannot be generalized. The results should be valuable information for researchers working with pre-clinical evaluation of device-associated E. coli infections.  相似文献   

14.
Kong X  Narine SS 《Biomacromolecules》2008,9(8):2221-2229
Sequential interpenetrating polymer networks (IPNs) were prepared using polyurethane produced from a canola oil based polyol with primary terminal functional groups and poly(methyl methacrylate) (PMMA). The properties of the material were studied and compared to the IPNs made from commercial castor oil using dynamic mechanical analysis, differential scanning calorimetry, as well as tensile measurements. The morphology of the IPNs was investigated using scanning electron microscopy and transmission electron microscopy. The chemical diversity of the starting materials allowed the evaluation of the effects of dangling chains and graftings on the properties of the IPNs. The polymerization process of canola oil based IPNs was accelerated because of the utilization of polyol with primary functional groups, which efficiently lessened the effect of dangling chains and yielded a higher degree of phase mixing. The mechanical properties of canola oil based IPNs containing more than 75 wt % PMMA were comparable to the corresponding castor oil based IPNs; both were superior to those of the constituent polymers due to the finely divided rubber and plastic combination structures in these IPNs. However, when PMMA content was less than 65 wt %, canola oil based IPNs exhibited a typical mechanical behavior of rigid plastics, whereas castor oil based IPNs showed a typical mechanical behavior of soft rubber. It is proposed that these new IPN materials with high performance prepared from alternative renewable resources can prove to be valuable substitutes for existing materials in various applications.  相似文献   

15.
Abdominal aortic aneurysm (AAA) can be defined as a permanent and irreversible dilation of the infrarenal aorta. AAAs are often considered to be an aorta with a diameter 1.5 times the normal infrarenal aorta diameter. This paper describes a technique to manufacture realistic silicone AAA models for use with experimental studies. This paper is concerned with the reconstruction and manufacturing process of patient-specific AAAs. 3D reconstruction from computed tomography scan data allows the AAA to be created. Mould sets are then designed for these AAA models utilizing computer aided designcomputer aided manufacture techniques and combined with the injection-moulding method. Silicone rubber forms the basis of the resulting AAA model. Assessment of wall thickness and overall percentage difference from the final silicone model to that of the computer-generated model was performed. In these realistic AAA models, wall thickness was found to vary by an average of 9.21%. The percentage difference in wall thickness recorded can be attributed to the contraction of the casting wax and the expansion of the silicone during model manufacture. This method may be used in conjunction with wall stress studies using the photoelastic method or in fluid dynamic studies using a laser-Doppler anemometry. In conclusion, these patient-specific rubber AAA models can be used in experimental investigations, but should be assessed for wall thickness variability once manufactured.  相似文献   

16.
doi: 10.1111/j.1741‐2358.2010.00419.x
Effect of accelerated ageing and surface sealing on the permanent deformation of auto‐polymerising soft linings Purpose: To compare the effects of different ageing methods on the permanent deformation of two permanent soft liners. Materials and methods: The materials selected were auto‐polymerising acrylic resin and silicone‐based reliners. Sealer coating was also evaluated. Sixty specimens of each reliner were manufactured (12.7 mm diameter and 19 mm length). Specimens were randomly distributed into 12 groups (n = 10) and submitted to one of the accelerated ageing processes. Permanent deformation tests were conducted with a mechanical device described within the American Dental Association specification number 18 with a compressive load of 750 gf applied for 30 s. All data were submitted for statistical analysis. Mann–Whitney test compared the effect of the surface sealer on each material and the permanent deformation of the materials in the same ageing group (p = 0.05). Kruskal–Wallis and Dunn tests compared all ageing groups of each material (p = 0.05). Results: The silicone‐based reliner presented a lower permanent deformation than the acrylic resin‐based reliner, regardless of the ageing procedure. The surface sealer coating was effective only for the thermocycled silicone group and the accelerated ageing processes affected only the permanent deformation of the acrylic resin‐based material. Conclusion: The silicone‐based reliner presented superior elastic properties and the thermocycling was more effective in ageing the materials.  相似文献   

17.
Microbial adhesion of four bacterial and two yeast strains isolated from explanted voice prostheses to silicone rubber before and after conditioning with a biosurfactant obtained from the probiotic bacterium Streptococcus thermophilus A was investigated in a parallel plate flow chamber. The silicone rubber with and without an adsorbed biosurfactant layer was characterized using contact angle measurements. Water contact angles indicated that the silicone rubber surface with adsorbed biosurfactant was more hydrophilic (58 degrees) than bare silicone rubber (109 degrees). The results obtained showed that the biosurfactant was effective in decreasing the initial deposition rates, and the number of bacterial cells adhering after 4 h, for all microorganisms tested. A decrease in the initial deposition rate was observed for Rothia dentocariosa GBJ 52/2B and Staphylococcus aureus GB 2/1 from 1937+/-194 to 179+/-21 microorganisms cm(-2) s(-1) and from 1255+/-54 to 233+/-26 microorganisms cm(-2) s(-1), respectively, accounting for an 86% reduction of the initial deposition rate for both strains. The number of bacterial cells adhering to the silicone rubber with preadsorbed biosurfactant after 4 h was further reduced by 89% and 97% by the two strains, respectively. The two yeast strains tested showed less reduction in adhesion after 4 h, to values between 67% and 70%. Such a pretreatment with surface-active compounds may constitute a promising strategy to reduce the microbial colonization rate of silicone rubber voice prostheses.  相似文献   

18.
Any biomaterial implanted within the human body is influenced by the interactions that take place between its surface and the surrounding biological milieu. These interactions are known to influence the tissue interface dynamic, and thus act to emphasize the need to study cell-surface interactions as part of any biomaterial design process. The work described here investigates the relationship between human osteoblast attachment, spreading and focal contact formation on selected surfaces using immunostaining and digital image processing for vinculin, a key focal adhesion component. Our observations show that a relationship exists between levels of cell attachment, the degree of vinculin-associated plaque formation and biocompatibility. It also suggests that cell adhesion is not indicative of how supportive a substrate is to cell spreading, and that cell spreading does not correlate with focal contact formation.  相似文献   

19.
Summary Silicone tubing is frequently used for gas exchange in cell culture systems, due to its biocompatibility and high permeability to CO2 and O2. In cell culture chambers, medium pH and oxygen levels are often maintained by gas exchange through a coil of silicone tubing. Culture medium is recirculated between the gas exchanger and the culture chamber which contains a suspension of cells. We report that the type of agent used for silicone vulcanization (peroxide or platinum) can markedly affect its biocompatibility, and that tobacco cell culture represents a particularly sensitive indicator of tubing cytotoxicity. Under the conditions studied (cell suspension maintained with forward-reverse flow and stirring), peroxide-cured silicone tubing was toxic to the tobacco BY2 cell culture, in contrast to the platinum-cured silicone tubing that was completely biocompatible. Upon further investigation by mass spectrometry, it was determined that a component with a molecular mass of 288 Da, possibly a tetrachlorinated biphenyl, was present in culture medium in contact with peroxide-cured tubing but not in medium in contact with platinum-cured tubing. Additional curing of peroxide-cured tubing resulted in cell morphology and viability comparable to controls. These data suggest that improperly cured silicone tubing can release catalytic byproducts which can be toxic to plant cells, and that the BY2 tobacco cells represent a suitable model system for studies of materials biocompatibility.  相似文献   

20.
Bacterial nanocellulose (BNC), synthesized by the bacterium Gluconacetobacter xylinus, is composed of highly hydrated fibrils (99 % water) with high mechanical strength. These exceptional material properties make BNC a novel biomaterial for many potential medical and tissue engineering applications. Recently, BNC with cellulose content of 15 % has been proposed as an implant material for auricular cartilage replacement, since it matches the mechanical requirements of human auricular cartilage. This study investigates the biocompatibility of BNC with increased cellulose content (17 %) to evaluate its response in vitro and in vivo. Cylindrical BNC structures (Ø48?×?20 mm) were produced, purified in a built-in house perfusion system, and compressed to increase the cellulose content in BNC hydrogels. The reduction of endotoxicity of the material was quantified by bacterial endotoxin analysis throughout the purification process. Afterward, the biocompatibility of the purified BNC hydrogels with cellulose content of 17 % was assessed in vitro and in vivo, according to standards set forth in ISO 10993. The endotoxin content in non-purified BNC (2,390 endotoxin units (EU)/ml) was reduced to 0.10 EU/ml after the purification process, level well below the endotoxin threshold set for medical devices. Furthermore, the biocompatibility tests demonstrated that densified BNC hydrogels are non-cytotoxic and cause a minimal foreign body response. In support with our previous findings, this study concludes that BNC with increased cellulose content of 17 % is a promising non-resorbable biomaterial for auricular cartilage tissue engineering, due to its similarity with auricular cartilage in terms of mechanical strength and host tissue response.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号