首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
局麻药连续伤口输注技术是区域阻滞的一种,其从源头上阻滞了切口伤害性刺激信号的发生与传导。作为新一代的术后镇痛方式,它通过一种与神经周围或切口中插管相连的弹力球囊或便携式电子泵实施患者自我控制式区域镇痛。与传统的术后镇痛方式相比,它可安全有效便捷的用于临床术后镇痛,又可避免硬膜外穿刺置管的风险,还能减少阿片类药物的应用,因而在安全镇痛和加速康复方面更有优势。本文就局麻药连续伤口输注技术的应用作以下综述,为临床术后多模式镇痛提供参考。  相似文献   

2.
The arrhythmogenic effect of atrial dilatation was studied by electrophysiological investigations carried out on 24 dogs. Atrial distension was evoked by increasing the pressure in the right atrium (12 to 14 mm Hg) or by the balloon dilatation of the left atrium. Programmed electrical stimulation of the heart was used for the electrophysiological investigations. In addition to the superficial ECG leads also atrial and ventricular epicardial electrograms were obtained for the ECG recording. Acute atrial dilatation led to shortening of the atrial refractory period, whereas neither impulse conduction of the heart, nor pacemaker activity of the sinus node exhibited any alteration. Atrial dilatation resulted in pathological atrial irritability, and early or frequent atrial stimulation caused atrial tachycardia of shorter (non sustained) or longer (sustained) duration. Repetitive atrial extrasystoles in response to early stimuli could also frequently be observed during atrial dilatation. The obtained results indicate that atrial dilatation is arrhythmogenic and may lead to the development of atrial tachycardia.  相似文献   

3.
Previous studies have suggested that anodal pacing enhances electrical conduction in the heart near the pacing site. It was hypothesized that enhanced conduction by anodal pacing would also enhance ventricular pressure in the heart. Left ventricular pressure measurements were made in isolated, Langendorff-perfused rabbit hearts by means of a Millar pressure transducer with the use of a balloon catheter fixed in the left ventricle. The pressure wave was analyzed for maximum pressure (Pmax) generated in the left ventricle and the work done by the left ventricle (Parea). Eight hearts were paced with monophasic square-wave pulses of varying amplitudes (2, 4, 6, and 8 V) with 100 pulses of each waveform delivered to the epicardium. Anodal stimulation pulses showed statistically significant improvement in mechanical response at 2, 4, and 8 V. Relative to unipolar cathodal pacing, unipolar anodal pacing improved Pmax by 4.4 +/- 2.3 (SD), 5.3 +/- 3.1, 3.5 +/- 4.9, and 4.8 +/- 1.9% at 2, 4, 6, and 8 V, respectively. Unipolar anodal stimulation also improved Parea by 9.0 +/- 3.0, 12.0 +/- 6.0, 10.1 +/- 7.7, and 11.9 +/- 6.0% at 2, 4, 6, and 8 V, respectively. Improvements in Pmax and Parea indicate that an anodally paced heart has a stronger mechanical response than does a cathodally paced heart. Anodal pacing might be useful as a novel therapeutic technology to treat mechanically impaired or failed hearts.  相似文献   

4.
介绍一种跨膈压测定的方法,并通过对8例正常人及9例慢性阻塞性肺病患者跨膈压(Pdi)的测定,观察了气囊充气量、气囊位置及测定体位对Pdi测定值的影响。结果显示:食道测压气囊和胃测压气囊充气量分别以0.2和0.5ml为宜;食道气囊放置在测压导管远端离鼻孔35~45cm时测得的食道负压(Pe)最低,且较稳定;Pe、胃压及Pdi测定值均随体位改变而有所不同。  相似文献   

5.
The relationship between esophageal pressure and juxtacardiac pressures was studied during positive end-expiratory pressure (PEEP) ventilation applied to both lungs or selectively to one lung. The experiments were performed in eight anesthetized dogs with balloon catheters in the esophagus and in the left and right pericardial and overlying pleural cavities and with an open-ended liquid-filled catheter in the pleural cavity. Bilateral PEEP (10, 20, and 30 cmH2O) caused progressive and similar increments in left and right pleural pressure. Selective PEEP, however, increased ipsilateral pleural balloon pressure more than contralateral pressure. The increase in ipsilateral pleural balloon pressure markedly exceeded the increase in esophageal pressure. There was a small increase in pleural open-ended catheter pressure that approximated the increase in esophageal pressure. During selective PEEP, pericardial balloon pressure remained uniform because of a decrease in ipsilateral pericardial transmural pressure. In conclusion, selective PEEP caused nonuniform increments in regional pleural balloon pressure. Left and right pericardial balloon pressure, however, increased uniformly with selective PEEP because of reduced ipsilateral pericardial transmural pressure. The esophageal balloon did not reflect the marked regional increments in pleural balloon pressure with selective PEEP and consistently underestimated the changes in pleural balloon pressure with general PEEP.  相似文献   

6.
目的:研究微导管可脱球囊技术治疗创伤性颈内动脉-海绵窦痿(TCCF)的临床意义。方法:4例TCCF患者采用微导管可脱球囊技术进行栓塞治疗,所有患者均随访6月以上。结果:3例TCCF患者一次性成功栓塞瘘口井保持颈内动脉通畅,1例瘘口复杂患者因球囊过早泄漏复发而行2次栓塞治疗闭塞颈内动脉。本组病例来发生严重并发症。结论:微导管可脱球囊技术对TCCF是一种微创、安全、有效的治疗方法。  相似文献   

7.
Computational models of stent deployment in arteries have been widely used to shed light on various aspects of stent design and optimisation. In this context, modelling of balloon expandable stents has proved challenging due to the complex mechanics of balloon–stent interaction and the difficulties involved in creating folded balloon geometries. In this study, a method to create a folded balloon model is presented and utilised to numerically model the accurate deployment of a stent in a realistic geometry of an atherosclerotic human coronary artery. Stent deployment is, however, commonly modelled by applying an increasing pressure to the stent, thereby neglecting the balloon. This method is compared to the realistic balloon expansion simulation to fully elucidate the limitations of this procedure. The results illustrate that inclusion of a realistic balloon model is essential for accurate modelling of stent deformation and stent stresses. An alternative balloon simulation procedure is presented however, which overcomes many of the limitations of the applied pressure approach by using elements which restrain the stent as the desired diameter is achieved. This study shows that direct application of pressure to the stent inner surface may be used as an optimal modelling strategy to estimate the stresses in the vessel wall using these restraining elements and hence offer a very efficient alternative approach to numerically modelling stent deployment within complex arterial geometries. The method is limited however, in that it can only predict final stresses in the stented vessel and not those occurring during stent expansion, in which case the balloon expansion model is required.  相似文献   

8.
Purpose: Using a radioactive solution-filled catheter for intravascular irradiation has the potential problem of chemical and radiological toxicity in the case of a balloon rupture. In order to reduce this risk, an innovative concentric balloon catheter was developed.Methods and Materials: The concentric balloon was made by inner and outer balloons filled with saline and radioactive solution, respectively. The optimal inner radius was determined by comparing the dose rate reduction vs. the volume reduction for various inner and outer radii for 188Re, 32P, and 90Y solutions.Results: For a balloon with an outer radius of 1.5 mm, there was no advantage of a concentric balloon. For balloons with outer radii of 3.0 and 5 mm, the optimal inner radius was 1.5 and 3 mm, respectively.Conclusions: With the newly designed concentric balloon, the risk of toxicity can be reduced while keeping the dose rate high enough so that the treatment times within tolerable limits are still maintained.  相似文献   

9.
The development of neurogenic pulmonary edema (NPE) can be elicited by an immediate epidural balloon compression of the thoracic spinal cord. To evaluate whether a slower balloon inflation could prevent NPE development, we examined the extent of NPE in animals lesioned with a rapid (5 microl - 5 microl - 5 microl) or slow rate (3 microl - 2 microl - 2 microl - 2 microl - 2 microl - 2 microl - 2 microl) of balloon inflation. These groups were compared with the NPE model (immediate inflation to 15 microl) and with healthy controls. Slow balloon inflation prevented NPE development, whereas the pulmonary index and histology revealed a massive pulmonary edema in the group with a rapid rate of balloon inflation. Pulmonary edema was preceded by a considerable decrease in heart rate during the inflation procedure. Moreover, rapid inflation of balloon in spinal channel to either 5 microl or 10 microl did not cause NPE. Thus, a slow rate of balloon inflation in the thoracic epidural space prevents the development of neurogenic pulmonary edema, most likely due to the better adaptation of the organism to acute circulatory changes (rapid elevation of systemic blood pressure accompanied by profound heart rate reduction) during the longer balloon inflation period. It should be noted that spinal cord transection at the same level did not cause neurogenic pulmonary edema.  相似文献   

10.
The percutaneous transluminal coronary angioplasty (PTCA) assisted with stenting technique has become a primary therapy to coronary heart disease. In practice, the structure conditions of both ends of stent/balloon system influence a stent's instantaneous expansion behavior. The transitory nonuniform expansion, the so-called dogboning, of stent/balloon system is one of the main reasons to induce the acute vascular injury at the two edges of a stent. This kind of vascular injury has a close relationship with the in-stent restenosis. In the present paper, the finite element method (FEM) was applied to simulate the transient expansion process of stent/balloon system with different stent structure and balloon length under the internal pressure. And two types of stent and six collocations of stent and balloon were modeled. Modeling results showed that the dogboning phenomenon can be eliminated by improving geometry of a stent or/and varying the length of balloon over stent. The above modeled results were further confirmed by following in situ observation.  相似文献   

11.
The Laks catheter is a triple-lumen balloon catheter used to distend the canine main pulmonary artery while recording right ventricular pressure and the arterial pressure distal to the balloon. A rise in arterial pressure reported to occur during distension has been attributed to vasoconstriction rather than passive obstruction by the balloon. We tested this in six anesthetized dogs by inflating the Laks catheter-balloon while recording pressure distal to the balloon from the Laks catheter as well as from additional catheters in right and left pulmonary arteries placed retrogradely through lobar branches following thoracotomy. We found that balloon inflation increased pressures in the arterial port of the Laks catheter and in the left pulmonary artery catheter but reduced it in the right pulmonary artery. Tightening a snare around the right pulmonary artery had the same effects on pressures. Similar results were obtained while cardiac output was controlled by left ventricular bypass perfusion in four dogs. We conclude that the Laks catheter-balloon obstructs flow to the right lung and that the arterial pressure rise recorded in it during balloon inflation cannot be distinguished from that caused by occlusion of the right pulmonary artery.  相似文献   

12.

Purpose

We retrospectively investigated the feasibility and clinical efficacy of balloon dilatation and subsequent retrievable stent insertion, when necessitated, for pyloric spasms after pylorus-preserving gastrectomy (PPG).

Materials and Methods

Forty-five patients experiencing pyloric spasms after PPG underwent fluoroscopic balloon dilations to alleviate obstructive symptoms due to delayed gastric emptying. Patients showing poor response to balloon dilation underwent subsequent retrievable stent insertion. Safety of the procedures was analyzed, and subjective symptoms and objective signs of pyloric spasms were analyzed and compared before and after treatment.

Results

Thirty-three patients (73.3%, 33/45) showed good response to balloon dilatation requiring no further treatment (balloon group). Conversely, 12 patients (26.7%, 12/45) showed poor or no response after balloon dilation requiring subsequent stent insertion (stent group). Balloon dilations and/or stent insertions were safely performed in all patients except one patient who suffered a transmural tear after balloon dilatation. In both groups, mean subjective symptom score was significantly improved and mean pyloric canal-to-height of the adjacent vertebral body ratio was significantly increased after the procedures (P <.05).

Conclusion

Balloon dilation is a safe and effective treatment for patients with pyloric spasms after PPG. In patients refractory to balloon dilations, retrievable stent placement can be a safe alternative tool.  相似文献   

13.
BACKGROUND: It has been suggested that the severity of acute vascular injury immediately after percutaneous transluminal coronary angioplasty (PTCA) or stent implantation correlates with the extent of neointimal hyperplasia and restenosis. However, the influence of prolonged or chronic vessel injury on the pathogenesis of restenosis is unclear. METHODS: Rabbit iliac arteries were balloon dilated for a short (1 min) or prolonged (10 min) period of time, or were chronically dilated and received a Palmaz-Schatz stent (balloon inflation for 1 min). All arteries were overexpanded to a balloon:artery ratio of 1.2:1 as determined by angiography. The arteries were removed 30 min and 4 weeks after the angioplasty procedures. The sites of injury were evaluated by gross histology and transmission electron microscopy (TEM). Cell death of medial smooth muscle cells (SMCs) was specified by TEM images 30 min after the procedures. Computer-assisted quantification of the neointimal cross-sectional areas was performed after 4 weeks using a light microscope connected to a digital image analyser. RESULTS: The results show that prolonged balloon dilatation and stent implantation increased necrotic SMC death compared with balloon dilatation for 1 min. After 30 min, increased staining of SMC nuclei, enlarged intercellular spaces and changes in SMC shape in the media indicated cell death induced by prolonged balloon dilatation or chronic stent injury. Stent implantation markedly augmented vessel damage by persistent compression of the media, compared with a balloon dilatation for 1 or 10 min. Both prolonged balloon dilatation and stent implantation increased neointimal hyperplasia at 4 weeks compared with balloon dilatation for 1 min (0.6 3 0.2 and 1.0 3 0.2 mm(2) versus 0.2 3 0.1 mm(2), P < 0.001 versus dilatation for 1 min). CONCLUSION: Prolonged or chronic vascular expansion due to long balloon-inflation periods or the implantation of stents increases medial SMC death, which subsequently stimulates neointimal growth in this restenosis model. Chronic vascular injury may be an important stimulus for restenosis after angioplasty procedures.  相似文献   

14.

Purpose

The aims of this study were to analyze the predictive factors for the use of intrauterine balloon insertion and to evaluate the efficacy and factors affecting failure of uterine tamponade with a Bakri balloon during cesarean section for abnormal placentation.

Methods

We reviewed the medical records of 137 patients who underwent elective cesarean section for placenta previa between July 2009 and March 2014. Cesarean section and Bakri balloon insertion were performed by a single qualified surgeon. The Bakri balloon was applied when blood loss during cesarean delivery exceeded 1,000 mL.

Results

Sixty-four patients (46.7%) required uterine balloon tamponade during cesarean section due to postpartum bleeding from the lower uterine segment, of whom 50 (78.1%) had placenta previa totalis. The overall success rate was 75% (48/64) for placenta previa patients. Previous cesarean section history, anterior placenta, peripartum platelet count, and disseminated intravascular coagulopathy all significantly differed according to balloon success or failure (all p<0.05). The drainage amount over 1 hour was 500 mL (20–1200 mL) in the balloon failure group and 60 mL (5–500 mL) in the balloon success group (p<0.01).

Conclusion

Intrauterine tamponade with a Bakri balloon is an adequate adjunct management for postpartum hemorrhage following cesarean section for placenta previa to preserve the uterus. This method is simple to apply, non-invasive, and inexpensive. However, possible factors related to failure of Bakri balloon tamponade for placenta previa patients such as prior cesarean section history, anterior placentation, thrombocytopenia, presence of DIC at the time of catheter insertion, and catheter drainage volume more than 500 mL within 1 hour of catheter placement should be recognized, and the next-line management should be prepared in advance.  相似文献   

15.
Stents are small tubelike structures, implanted in coronary and peripheral arteries to reopen narrowed vessel sections. This endovascular intervention remains suboptimal, as the success rate is limited by restenosis. This renarrowing of a stented vessel is related to the arterial injury caused by stent-artery and balloon-artery interactions, and a local subsequent inflammatory process. Therefore, efforts to optimize the stent deployment remain very meaningful. Several authors have studied with finite element modeling the mechanical behavior of balloon-expandable stents, but none of the proposed models incorporates the folding pattern of the balloon. We developed a numerical model in which the CYPHER stent is combined with a realistic trifolded balloon. In this paper, the impact of several parameters such as balloon length, folding pattern, and relative position of the stent with respect to the balloon catheter on the free stent expansion has been investigated. Quantitative validation of the modeling strategy shows excellent agreement with data provided by the manufacturer and, therefore, the model serves as a solid basis for further investigations. The parametric analyses showed that both the balloon length and the folding pattern have a considerable influence on the uniformity and symmetry of the transient stent expansion. Consequently, this approach can be used to select the most appropriate balloon length and folding pattern for a particular stent design in order to optimize the stent deployment. Furthermore, it was demonstrated that small positioning inaccuracies may change the expansion behavior of a stent. Therefore, the placement of the stent on the balloon catheter should be accurately carried out, again in order to decrease the endothelial damage.  相似文献   

16.
Computational investigations of flow mixing and oxygen transfer characteristics in an intravenous membrane oxygenator (IMO) are performed by direct numerical simulations of the conservation of mass, momentum, and species equations. Three-dimensional computational models are developed to investigate flow-mixing and oxygen-transfer characteristics for stationary and pulsating balloons, using the spectral element method. For a stationary balloon, the effect of the fiber placement within the fiber bundle and the number of fiber rings is investigated. In a pulsating balloon, the flow mixing characteristics are determined and the oxygen transfer rate is evaluated. For a stationary balloon, numerical simulations show two well-defined flow patterns that depend on the region of the IMO device. Successive increases of the Reynolds number raise the longitudinal velocity without creating secondary flow. This characteristic is not affected by staggered or non-staggered fiber placement within the fiber bundle. For a pulsating balloon, the flow mixing is enhanced by generating a three-dimensional time-dependent flow characterized by oscillatory radial, pulsatile longitudinal, and both oscillatory and random tangential velocities. This three-dimensional flow increases the flow mixing due to an active time-dependent secondary flow, particularly around the fibers. Analytical models show the fiber bundle placement effect on the pressure gradient and flow pattern. The oxygen transport from the fiber surface to the mean flow is due to a dominant radial diffusion mechanism, for the stationary balloon. The oxygen transfer rate reaches an asymptotic behavior at relatively low Reynolds numbers. For a pulsating balloon, the time-dependent oxygen-concentration field resembles the oscillatory and wavy nature of the time-dependent flow. Sherwood number evaluations demonstrate that balloon pulsations enhance the oxygen transfer rate, even for smaller flow rates.  相似文献   

17.
We aimed to determine whether rectal distension and/or infusion of bile acids stimulates propagating or nonpropagating activity in the unprepared proximal colon in 10 healthy volunteers using a nasocolonic manometric catheter (16 recording sites at 7.5-cm spacing). Sensory thresholds and proximal colonic motor responses were assessed following rectal distension by balloon inflation and rectal instillation of chenodeoxycholic acid. Maximum tolerated balloon volume and the volume that stimulated a desire to defecate were both significantly (P < 0.01) reduced after rectal chenodeoxycholic acid. The frequency of colonic propagating pressure wave sequences decreased significantly in response to initial balloon inflations (P < 0.05), but the frequency doubled after subsequent chenodeoxycholic acid infusion (P < 0.002). Nonpropagating activity decreased after balloon inflation, was not influenced by acid infusion, and demonstrated a further decrease in response to repeat balloon inflation. We concluded that rectal chenodeoxycholic acid in physiological concentrations is a potent stimulus for propagating pressure waves arising in the proximal colon and reduces rectal sensory thresholds. Rectal distension inhibits all colonic motor activity.  相似文献   

18.
Pulvirenti  T. J.  Yin  J. L.  Chaufour  X.  McLachlan  C.  Hambly  B. D.  Bennett  M. R.  Barden  J. A. 《Brain Cell Biology》2000,29(9):623-631
The redistribution of purinergic P2X receptor subunits (P2X1 to P2X7) within the rabbit aorta wall three weeks after endothelial balloon injury/cholesterol feeding was examined. P2X1 receptor cluster density was elevated in the media following balloon injury/cholesterol feeding by about 30% and these clusters appeared on smooth muscle cells throughout the greatly expanded neointima but they did not change significantly on the endothelial cells following balloon injury. P2X4 clusters were found in high density throughout the media and in very high density in the enlarged neointima following balloon injury, particularly on the endothelial cells where the density increased about 10-fold after balloon injury. P2X5 clusters were found in high density in the media of normal aorta but with little change following balloon injury. P2X3, P2X6 and P2X7 cluster density was low in normal aorta and remained unchanged following balloon injury. All receptor subunits were found on endothelial cells. It is suggested that the release of ATP from damaged endothelial cells and from smooth muscle cells sufficient to activate P2X4 receptors may contribute to neointimal proliferation.  相似文献   

19.
Colonic transit is slowed in patients with disordered rectal evacuation, but the mechanism of this phenomenon is unclear. Our objective was to investigate rectocolonic inhibitory reflexes in humans to provide potential insight into patients with obstructed defecation. In 30 healthy subjects, a barostat-manometric assembly recorded colonic tone and phasic activity in the descending colon during rectal distension and recorded rectal tone during colonic distension. Phasic distensions were 8, 16, and 32 mmHg above balloon operating pressure, and staircase inflations were comprised of balloon inflation then deflation in 2-mmHg increments at 30-s intervals from 0 to 36 mmHg. Colonic balloon volumes increased to a similar extent during phasic rectal distensions 8, 16, and 32 mmHg above operating pressure, reflecting reduced colonic tone; balloon volumes also increased and phasic pressure activity decreased during staircase rectal distensions. In contrast, rectal balloon volume declined, reflecting increased tone during phasic and staircase colonic distensions. Thus rectal distension inhibited colonic motor activity, indicative of a viscerovisceral inhibitory reflex.  相似文献   

20.
目的:观察双气囊小肠镜在小肠出血中的病变检出率、病因诊断率、耐受性和安全性,并探讨双气囊小肠镜对小肠出血的内镜下治疗情况.方法:对2006年3月至2009年11月烟台毓璜顶医院消化内科收治的可疑小肠出血患者102例行双气囊小肠镜检查,首选进镜方式分为经口或经肛2种,首选方式检查后未发现病灶者,日后改换进镜方式再行检查.对活动性出血病灶行内镜下止血治疗,小肠息内行息肉切除.结果:双气囊小肠镜的病变检出率为94.12%(96/102),病因诊断率为84.31%(86/102).其中35例检查时见病变活动性出血,行内镜下止血治疗,33倒止血成功,内镜止血成功率为94.30%(33/35);在耐受性方面.双气囊小肠镜的耐受性依次为:全麻下经肛进镜、全麻下经口进镜、非麻醉经肛进镜、非麻醉经口进镜.所有患者均未发生严重并发症.结论:双气囊小肠镜对小肠出血具有较高的病变检出率和病因诊断率,并且可行内镜下止血治疗,是一项安全、有效的临床诊疗方法.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号