Background and Purpose

Accurate measurement of aortic annulus diameter is crucial for choosing suitable prosthetic size for transcatheter aortic valve implantation (TAVI). Several imaging methods are available for the measurement, but significant variability between different modalities has been observed. The purpose of this study was to systematically compare the measurements of aortic annulus diameter between multi-detector computed tomography (MDCT), transthoracic echocardiography (TTE), and transesophegeal echocardiography (TEE).

Methods

PubMed and EMBASE databases between January 2000 and January 2012 were searched. We extracted data from eligible studies evaluating the aortic annulus diameter by MDCT and echocardiography (TTE, TEE, or both). We performed a random-effects meta-analysis to calculate the weighted mean differences of aortic annulus diameter measurement between MDCT, TTE, and TEE.

Results

A total of 10 eligible studies involving 581 subjects with aortic valve stenosis were included. Aortic annulus diameter measured on coronal view by MDCT (25.3±0.52 mm) was respectively larger than that measured on sagittal view by MDCT (22.7±0.37 mm), TTE (22.6±0.28 mm), and TEE (23.1±0.32 mm). The weighted mean difference of aortic annulus diameter between coronal view by MDCT and TTE these two methods was 2.97 mm, followed by the weighted mean difference of 2.53 mm between coronal view and sagittal view by MDCT, and the mean difference of 1.74 mm between coronal view on MDCT and TEE (P<0.0001 for all). The weighted mean difference of aortic annulus diameter measurement between TEE and TTE was significant but somewhat small (0.45 mm, P = 0.007).

Conclusion

Aortic annulus diameter measured on coronal view by MDCT was robustly and significantly larger than that obtained on sagittal view by MDCT, TTE, or TEE. Such variability of aortic annulus diameter measurement by different imaging modalities cannot be ignored when developing optimal strategies for selection of prosthetic valve size in TAVI.  相似文献   

2.
"Difficult to cure infections" are characterized by poor penetration of antibiotics into infected vegetations, altered metabolic state of bacteria within the vegetation, absence of adequate host defense/cellular response. These infections typically include endocarditis, urinary tract infections (infected urinary tract stones), abscesses, infected fibrin clots (septic thromboemboli, haematomas, catheter-related infections) and foreign body infections. Four main aspects are discussed for the influence on human therapy: 1. the kinetics of antibiotic diffusion into vegetations 2. the specificity of some pharmacodynamic aspects and pharmacokinetic regimes 3. fibrin as one of the main constituents associated with infectious processes and 4. synergistical activities of antibiotic combinations on bacterial vegetations.  相似文献   

3.
Objective. To determine the influence of transoesophageal echocardiography (TEE) on therapy and prognosis in patients with cryptogenic transient ischaemic attack (TIA) or ischaemic stroke under the age of 50 years. Methods and results. We evaluated all patients aged 50 and under who were referred to our university hospital for cryptogenic TIA or ischaemic stroke during the period 1 January 1996 to 31 December 2004. All patients underwent both transthoracic echocardiography (TTE) and TEE. Patients with known pre-existent heart disease, such as atrial fibrillation, were excluded. Eighty-three patients with TIA (22) and ischaemic stroke (61) were enrolled. Mean age was 39±8 years (range 18 to 50). In 30% of the patients TEE detected one or more potential cardioembolic source, compared with 10% for TTE (p=0.003). Standard treatment (aspirin 38 mg daily) was changed in 7% of the patients due to the TEE findings. Complete followup was obtained in 93% with an average of 5±3 years. Twelve recurrences occurred; two out of six patients (33%) with therapy change and ten out of 71 (14%) of the patients without therapy change had a recurrent TIA or ischaemic Stroke. Conclusion. In patients with cryptogenic TIA or ischaemic stroke, TEE is superior to TTE in the detection of a potential cardiac source of embolism. However, findings obtained by TEE only influence the already initiated treatment in a small percentage of patients. The recurrence rate both in the group with and without therapy change is high. (Neth Heart J 2009;17:373–7.)  相似文献   

4.
《Médecine Nucléaire》2014,38(5):293-298
Positron emission tomography (PET) with fluorodeoxyglucose (FDG) is a nuclear imaging method whose interest in oncology has only grown over the past fifteen years. This article summarizes the results in monitoring and therapeutic evaluation of breast cancer. For the search of locoregional or distant recurrence, the performance of FDG-PET are very interesting. The impact of FDG-PET on the therapeutic management is undeniable. For therapeutic evaluation, this imaging is useful to evaluate the neoadjuvant chemotherapy and hormonotherapy efficacy. FDG-PET is indicated in cases of suspected recurrence (clinical, biological or imaging suspicious). It is the most sensitive exam for the detection of bone or visceral metastases. It allows the re-staging during a relapse proved whether local or remote, and can change the therapeutic management.  相似文献   

5.
Five patients were found during surgery or at necropsy to have the mitral valve orifice obstructed by vegetations. They had had unexplained severe and recurrent episodes of acute febrile pulmonary oedema, and four had few cardiac ausculatory findings. Three patients died suddenly and unexpectedly; the other two were operated on and survived. In view of its ominous prognosis, acute mitral valve obstruction should be considered in patients whose pulmonary symptoms are compatible with endocarditis and are not adequately explained by the findings on examination of the heart. The condition, which should be confirmed by echocardiography, requires emergency surgery.  相似文献   

6.
Sensitivity of thyroglobulin (Tg) measurement in the follow-up of differentiated thyroid carcinoma (DTC) can be optimized by using a sensitive Tg assay and rhTSH stimulation. We evaluated the diagnostic yield of a sensitive Tg assay and rhTSH stimulated Tg in the detection of recurrences in the follow-up of DTC. Additionally the value of imaging techniques for the localization of recurrences was evaluated. We included 121 disease free patients in long-term follow-up for DTC (median 10 years, range 1-34). Tg during thyroid hormone suppression therapy (Tg-on) and rhTSH stimulated Tg were measured with a sensitive Tg assay. Patients with rhTSH stimulated Tg > or =1.0 ng/ml underwent imaging with neck ultrasound, FDG-PET and post therapy 131I WBS. Sensitive Tg measurement resulted in 3 patients with Tg-on > or =1.0 ng/ml, recurrence could be localized in 2 of them. RhTSH stimulation resulted in Tg > or =1.0 ng/ml in another 17 of 118 patients. Recurrence could be localized in only 1 additional patient (1 out of 118 patients). Recurrence was localized by neck ultrasound in 1 of 3, by FDG-PET in 2 of 3 and by post therapy 131I WBS in 2 of 3 patients. In the detection of recurrences in DTC, rhTSH stimulation had very limited additional value in comparison to Tg-on measurement with a sensitive Tg assay. We consider this too low to justify rhTSH stimulation in all patients during long-term follow up. Neck ultrasound, FDG-PET and post therapy 131I WBS showed complementary value in localization of disease, but were only positive in a small fracture of all procedures.  相似文献   

7.
We present a patient with a pacemaker lead endocarditis who showed no signs of pocket infection but with high fever and signs of infection in the routine laboratory tests. A diagnosis of pacemaker lead endocarditis must be considered in all patients with fever and infection parameters who have a pacemaker inserted, not only in the first weeks after implantation but also late after implantation, as long as no other cause of infection has been found. Transthoracal echocardiography alone is not sensitive enough to establish the correct diagnosis. Transoesophageal echocardiography (TEE) is mandatory to demonstrate the presence or absence of a vegetation on a pacemaker lead.  相似文献   

8.
A 28-year-old male presenting with atrial fibrillation (AF) underwent successful electrical cardioversion to restore sinus rhythm. He had no prior history of AF or other cardiac disease. However, transthoracic echocardiography (TTE), performed to exclude structural abnormalities as a cause of AF, demonstrated a large mass in the left atrium (LA). For further analysis the patient was referred to our centre, and echocardiography, multislice detector computed tomography (MDCT) and cardiovascular magnetic resonance imaging (CMR) were performed for further noninvasive diagnostic work-up.  相似文献   

9.
Two new detection methods for the determination of poly-beta-hydroxybutyrate (PHB) and -valerate (PHV) are described. Both methods are based on depolymerization of PHB/PHV to 3-hydroxybutyrate (3HB) and 3-hydroxyvalerate (3HV). Depolymerization was achieved by either propanolic or hydrolytic digestion. Propanolic digestion transformed commercial PHB/PHV stoichiometrically into 3HB/3HV and yielded apparently complete recoveries of bacterial PHB/PHV from activated sludge. Hydrolytic digestion was suitable only for PHB determination. For quantification of 3HB and 3HV directly from digested sludge, a method based on ion-exchange chromatography and conductivity detection was developed (IC-method). Alternatively, the total of 3HB and 3HV was quantified using a commercial enzymatic test kit and colorimetric detection (enzyme method). Both detection methods are easier to perform than previous methods and are suitable for complex matrices such as activated sludge. The IC-method is recommended for high sample throughputs or if distinction between PHB and PHV is essential. Enzymatic detection is recommended if a few samples per day have to be measured immediately or if an ion chromatograph is unavailable.  相似文献   

10.
Three cases of acute rupture of the aortic cusp complicating bacterial endocarditis are described. Special emphasis is placed on the value of serial echocardiography as a means of identifying progressive changes in aortic valve anatomy during the destructive process of the disease. Prior to the results of blood cultures, an echocardiogram confirmed a diagnosis of vegetations on the valve cusps. It also demonstrated flailing of the aortic cusp, which was confirmed at operation. Echocardiographic findings of flailing aortic valves in these patients coincided with the onset of acute aortic insufficiency and contributed to the timing of surgical intervention for replacement of the affected valves.  相似文献   

11.
We studied 8 adult patients with variable symptoms of cough, dyspnea, stridor, wheezing, or hemoptysis. Fiberoptic bronchoscopy in all showed complete or nearly complete endobronchial obstruction of a main-stem bronchus by neoplasm with a mean bronchial diameter of 1.9 mm +/- 1.6 mm (mean +/- standard deviation). In 4 patients, a lobar bronchus was also completely obstructed. No mass was visible on chest radiographs of any patient; however, computed tomography in each showed main-stem endobronchial obstruction, lobar obstruction (4 instances in 3 patients), and in 6 patients hypoperfusion of the involved lung. Computed tomographic scan showed additional abnormalities that were unsuspected on viewing chest radiographs or at bronchoscopy, including mediastinal adenopathy in 3 patients and an extraluminal tumor component in 4. After therapy with Nd-YAG laser, main-stem airway diameter increased to a mean of 9.6 mm +/- 1.0 mm (P less than .05) and pulmonary functions improved. Results suggest the complementary role of computed tomography and fiberoptic bronchoscopy in the detection and laser-treatment planning of chest radiographically occult severe neoplastic obstruction of the main-stem bronchus.  相似文献   

12.
Introduction

Infective endocarditis (IE) is associated with a high in-hospital and long term mortality. Although progress has been made in diagnostic approach and management of IE, morbidity and mortality of IE remain high. In the latest European guidelines, the importance of the multi-modality imaging in diagnosis and follow up of IE is emphasized.

Aim

The aim was to provide information regarding mortality and adverse events of IE, to determine IE characteristics and to assess current use of imaging in the diagnostic workup of IE.

Methods

This is a prospective observational cohort study. We used data from the EURO-ENDO registry. Seven hospitals in the Netherlands have participated and included patients with IE between April 2016 and April 2018.

Results

A total of 139 IE patients were included. Prosthetic valve endocarditis constituted 32.4% of the cases, cardiac device related IE 7.2% and aortic root prosthesis IE 3.6%. In-hospital mortality was 14.4% (20 patients) and one-year mortality was 21.6% (30 patients). The incidence of embolic events under treatment was 16.5%, while congestive heart failure or cardiogenic shock occurred in 15.1% of the patients. Transthoracic and transoesophageal echocardiography were performed most frequently (97.8%; 81.3%) and within 3 days after IE suspicion, followed by 18F‑fluorodeoxyglucose positron emission tomography/computed tomography (45.3%) within 6 days and multi-slice computed tomography (42.4%) within 7 days.

Conclusion

We observed a high percentage of prosthetic valve endocarditis, rapid and extensive use of imaging and a relatively low in-hospital and one-year mortality of IE in the Netherlands. Limitations include possible selection bias.

  相似文献   

13.
The dysfunction of left atrial appendage (LAA) is prone to form thrombus when atrial fibrillation (AF) sustained more than 48 h. Traditional 2D-TEE (transesophageal echocardiography) can not accurate evaluate the function of LAA. The purpose of this study is to analyze the relationship of LAA function parameters and thrombus formation in patients with non-valvular atrial fibrillation (NVAF) by real-time three-dimensional transesophageal echocardiography (RT-3D-TEE). High risk patients can be identified according to the characteristics of ultrasonic index in patients with left atrial appendage thrombosis, which has important clinical value and significance in the risk assessment, guiding treatment and judging prognosis. We examined the relationship between the echocardiographic parameters of LAA function and the incidence of thrombus in 102 NVAF patients. They underwent RT-3D-TEE and left atrial appendage thrombus (LAAT)/severe spontaneous echocardiographic contrast (SSEC) was found in 67 patients (thrombus group) but absent in the remaining 35 patients (non-thrombus group). After measured by QLAB software, the LAA functional parameters were significantly associated with LAAT/SEC formation. Univariate analysis indicated that AF time, LAD, LVEF, LAA-OAmax, LAAVmax, LAAVI and LAAEF demonstrated a positive association (P < 0.05). However, logistic regression analysis identified that AF time (OR:1.73, P < 0.05)、LAAEF (OR:4.09, P < 0.01)and LAAVI (OR:3.28, P < 0.01) were independent predictors of LAAT/SSEC. In patients with nonvalvular atrial fibrillation, echocardiographic parameters of LAA function are significantly associated with LAAT/SSEC.  相似文献   

14.
M-mode echocardiograms of two patients with bacterial endocarditis of approximately 4 months' duration showed dense echoes in the area of the aortic valve. In one patient, who had no prior abnormal cardiac findings, the echoes were clearly suggestive of valvular vegetations. The second patient, however, was known to have had aortic valve disease and a systolic murmur for more than a decade; therefore, dense echoes arising from the aortic valve also could have resulted from valvular calcification. In both patients, cross-sectional echocardiography provided important information. In the first patient, retrograde cardiac catheterization was prevented by large and highly mobile masses attached to the aortic cusps that prolapsed into the left ventricular outflow tract during diastole. Aortic valve replacement without further hemodynamic evaluation was recommended. In the second patient, whose blood cultures remained negative after the acute phase of his illness had been treated, cross-sectional echocardiography showed large vegetations on the aortic valve. Intraoperative findings confirmed the echocardiographic interpretation in each case.  相似文献   

15.
The purpose of this study was to validate low radiation dose, contrast‐enhanced, multi‐detector computed tomography (MDCT) as a non‐invasive method for measuring ovarian volume in macaques. Computed tomography scans of four known‐volume phantoms and nine mature female cynomolgus macaques were acquired using a previously described, low radiation dose scanning protocol, intravenous contrast enhancement, and a 32‐slice MDCT scanner. Immediately following MDCT, ovaries were surgically removed and the ovarian weights were measured. The ovarian volumes were determined using water displacement. A veterinary radiologist who was unaware of actual volumes measured ovarian CT volumes three times, using a laptop computer, pen display tablet, hand‐traced regions of interest, and free image analysis software. A statistician selected and performed all tests comparing the actual and CT data. Ovaries were successfully located in all MDCT scans. The iliac arteries and veins, uterus, fallopian tubes, cervix, ureters, urinary bladder, rectum, and colon were also consistently visualized. Large antral follicles were detected in six ovaries. Phantom mean CT volume was 0.702±SD 0.504 cc and the mean actual volume was 0.743±SD 0.526 cc. Ovary mean CT volume was 0.258±SD 0.159 cc and mean water displacement volume was 0.257±SD 0.145 cc. For phantoms, the mean coefficient of variation for CT volumes was 2.5%. For ovaries, the least squares mean coefficient of variation for CT volumes was 5.4%. The ovarian CT volume was significantly associated with actual ovarian volume (ICC coefficient 0.79, regression coefficient 0.5, P=0.0006) and the actual ovarian weight (ICC coefficient 0.62, regression coefficient 0.6, P=0.015). There was no association between the CT volume accuracy and mean ovarian CT density (degree of intravenous contrast enhancement), and there was no proportional or fixed bias in the CT volume measurements. Findings from this study indicate that MDCT is a valid non‐invasive technique for measuring the ovarian volume in macaques. Am. J. Primatol. 72:530–538, 2010. © 2010 Wiley‐Liss, Inc.  相似文献   

16.
17.
M K Kapral  F L Silver 《CMAJ》1999,161(8):989-996
OBJECTIVE: To develop guidelines for the use of echocardiography in the investigation of patients with stroke. OPTIONS: (1) Routine transthoracic echocardiography (TTE); (2) routine transesophageal echocardiography (TEE); (3) routine TTE followed by TEE if the TTE findings are noncontributory; (4) selective TTE or TEE in patients with cardiac disease who would not otherwise receive anticoagulant therapy. OUTCOMES: This article reviews the available evidence on the yield of TTE and TEE in detecting cardiac sources of cerebral emboli in patients with stroke, the effectiveness of treatment for cardiac sources of emboli and the effectiveness of screening echocardiography for secondary stroke prevention. EVIDENCE: MEDLINE was searched for relevant articles published from January 1966 to April 1998; also reviewed were additional articles identified from the bibliographies and citations obtained from experts. BENEFITS, HARMS AND COSTS: Echocardiography can detect intracardiac masses (thrombus, vegetation or tumour) in about 4% (with TTE) to 11% (with TEE) of stroke patients. The yield is lower among patients without clinical evidence of cardiac disease by history, physical examination, electrocardiography or chest radiography (less than 2%) than among patients with clinical evidence of cardiac disease (less than 19%). The risks of echocardiography to patients are small. TTE has virtually no risks, and TEE is associated with cardiac, pulmonary and bleeding complications in 0.18%. Patients with an identified intracardiac thrombus are at increased risk for embolic events (absolute risk uncertain, range 0%-38%), and this appears to be reduced with anticoagulant therapy (absolute risk reduction uncertain). Anticoagulant therapy carries a risk of major hemorrhage of 1% to 3% per year. The overall effectiveness of echocardiography in the prevention of recurrent stroke is unknown. VALUES: The strength of evidence was evaluated using the methods of the Canadian Task Force on Preventive Health Care. RECOMMENDATIONS: There is fair evidence to recommend echocardiography in patients with stroke and clinical evidence of cardiac disease by history, physical examination, electrocardiography or chest radiography (grade B recommendation). There is insufficient evidence to recommend for or against TEE in patients with normal results of TTE (grade C recommendation). There is insufficient evidence to recommend for or against routine echocardiography in patients (including young patients) without clinical cardiac disease (grade C recommendation). Routine echocardiography is not recommended for patients with clinical cardiac disease who have independent indications for or contraindications to anticoagulant therapy (grade D recommendation). There is fair evidence to recommend anticoagulant therapy in patients with stroke and intracardiac thrombus (grade B recommendation). There is insufficient (no) evidence to recommend for or against any specific therapy for patent foramen ovale (grade C recommendation). VALIDATION: The findings of this analysis were reviewed through an iterative process by the members of the Canadian Task Force on Preventive Health Care.  相似文献   

18.

Introduction

Left atrial appendage (LAA) closure has become of major interest for patients with atrial fibrillation intolerant to oral anticoagulation therapy (OAC). Patients with a contraindication to both OAC and antiplatelet therapy are not eligible for percutaneous LAA closure. We aimed to find an alternative treatment for these specific patients.

Methods

From March 2014 until December 2015 five patients were referred for percutaneous LAA closure. Alternative treatment was necessary due to an absolute contraindication to OAC and antiplatelet therapy (n = 4) or after previous failed percutaneous device implantation (n = 1). A stand-alone full thoracoscopic closure of the LAA using the Atriclip PRO device (AtriCure Inc., Dayton, OH, USA) was performed under guidance of transoesophageal echocardiography (TEE). After three months all patients underwent a computed tomography scan. Mean follow-up was 7.2 months [range 4.5–9.8 months].

Results

All procedures were achieved without the occurrence of complications. Complete LAA closure was obtained in all patients without any residual flow confirmed by TEE. Postoperative computed tomography confirmed persisting adequate clip positioning with complete LAA closure and absence of intracardial thrombi. During follow-up no thromboembolic events occurred.

Conclusion

For atrial fibrillation patients with an absolute contraindication to OAC and antiplatelet therapy a stand-alone, minimally invasive thoracoscopic closure of the LAA is a safe and feasible alternative treatment. This might be a solution to avoid serious bleeding complications while eliminating the thromboembolic risk originating from the LAA in patients who are not eligible for percutaneous LAA closure.
  相似文献   

19.

Introduction

Structural heart interventions are guided by transoesophageal or intracardiac echocardiography (TEE/ICE). MicroTEE, developed for paediatric purposes, is smaller and therefore less invasive and traumatic, avoiding the need for general anaesthesia. We aimed to show feasibility of procedural guidance by comparing image quality of microTEE with standard TEE and ICE during adult transcatheter interventions, and assess the accuracy in obtaining left atrial appendage (LAA) measurements between the microTEE probe and standard TEE.

Methods and results

We prospectively included 49 patients (20 women, 64 ± 18 years). Intraprocedural images were obtained by using the microTEE probe and standard (2D and 3D) TEE (LAA closure, MitraClip implantation) or ICE (interatrial communication closure, transseptal puncture for left atrial ablation). Two echocardiographers independently assessed image quality from 1 (excellent) to 4 (poor) and performed LAA measurements. Use of microTEE was not related to significant discomfort. Image quality obtained with the microTEE probe was lower than with standard TEE (2 [1–2] vs. 1 [1–2]; p = 0.04) and comparable with ICE images (2 [1–2] vs. 2 [1–2], p = 0.13). MicroTEE showed a wider field of view than ICE. LAA measurements on images obtained by microTEE were strongly associated with standard TEE.

Conclusions

MicroTEE seems feasible for guidance during transcatheter heart interventions in adults. MicroTEE imaging offers a wider field of view than ICE, and its accuracy is comparable with TEE. In transcatheter interventions performed under conscious sedation, microTEE might be a viable and advantageous alternative to standard TEE or ICE.
  相似文献   

20.
Pulmonary paragonimiasis is a relatively rare cause of lung disease revealing a wide variety of radiologic findings, such as air-space consolidation, nodules, and cysts. We describe here a case of pulmonary paragonimiasis in a 27-year-old woman who presented with a 2-month history of cough and sputum. Based on chest computed tomography (CT) scans and fluorodeoxyglucose positron emission tomography (FDG-PET) findings, the patient was suspected to have a metastatic lung tumor. However, she was diagnosed as having Paragonimus westermani infection by an immunoserological examination using ELISA. Follow-up chest X-ray and CT scans after chemotherapy with praziquantel showed an obvious improvement. There have been several reported cases of pulmonary paragonimiasis mimicking lung tumors on FDG-PET. However, all of them were suspected as primary lung tumors. To our knowledge, this patient represents the first case of paragonimiasis mimicking metastatic lung disease on FDG-PET CT imaging.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号