首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Introduction

Non response to cardiac resynchronisation therapy (CRT) may be related to the position of the coronary sinus lead.

Methods

We studied the acute haemodynamic response (AHR) from alternative left ventricular (LV) endocardial pacing sites in clinical non-responders to CRT. AHR and the interval from QRS onset to LV sensing (Q-LV interval) from four different endocardial pacing sites were evaluated in 24 clinical non-responders. A rise in LVdP/dtmax ≥ 15 % from baseline was considered a positive AHR. We also compared the AHR from endocardial with the corresponding epicardial lead position.

Results

The implanted system showed an AHR ≥ 15 % in 5 patients. In 9 of the 19 remaining patients, AHR could be elevated to ≥ 15 % by endocardial LV pacing. The optimal endocardial pacing site was posterolateral. There was no significant difference in AHR between the epicardial and the corresponding endocardial position. The longest Q-LV interval corresponded with the best AHR in 12 out of the 14 patients with a positive AHR, with an average Q-LV/QRS width ratio of 90 %.

Conclusions

Acute haemodynamic testing may indicate an alternative endocardial pacing site with a positive AHR in clinical non-responders. The Q-LV interval is a strongly correlated with the optimal endocardial pacing site. Endocardial pacing opposite epicardial sites does not result in a better AHR.  相似文献   

2.

Background

The contribution of right ventricular (RV) stimulation to cardiac resynchronisation therapy (CRT) remains controversial. RV stimulation might be associated with adverse haemodynamic effects, dependent on intrinsic right bundle branch conduction, presence of scar, RV function and other factors which may partly explain non-response to CRT. This study investigates to what degree RV stimulation modulates response to biventricular (BiV) stimulation in CRT candidates and which baseline factors, assessed by cardiac magnetic resonance imaging, determine this modulation.

Methods and results

Forty-one patients (24 (59 %) males, 67 ± 10 years, QRS 153 ± 22 ms, 21 (51 %) ischaemic cardiomyopathy, left ventricular (LV) ejection fraction 25 ± 7 %), who successfully underwent temporary stimulation with pacing leads in the RV apex (RVapex) and left ventricular posterolateral (PL) wall were included. Stroke work, assessed by a conductance catheter, was used to assess acute haemodynamic response during baseline conditions and RVapex, PL (LV) and PL+RVapex (BiV) stimulation.Compared with baseline, stroke work improved similarly during LV and BiV stimulation (∆+ 51 ± 42 % and ∆+ 48 ± 47 %, both p < 0.001), but individual response showed substantial differences between LV and BiV stimulation. Multivariate analysis revealed that RV ejection fraction (β = 1.01, p = 0.02) was an independent predictor for stroke work response during LV stimulation, but not for BiV stimulation. Other parameters, including atrioventricular delay and scar presence and localisation, did not predict stroke work response in CRT.

Conclusion

The haemodynamic effect of addition of RVapex stimulation to LV stimulation differs widely among patients receiving CRT. Poor RV function is associated with poor response to LV but not BiV stimulation.

Electronic supplementary material

The online version of this article (doi:10.1007/s12471-015-0770-x) contains supplementary material, which is available to authorized users.  相似文献   

3.

Background

Change in left ventricular end-systolic volume (∆LVESV) is the most frequently used surrogate marker in measuring response to cardiac resynchronisation therapy (CRT). We investigated whether ∆LVESV is the best measure to discriminate between a favourable and unfavourable outcome and whether this is equally applicable to non-ischaemic and ischaemic cardiomyopathy.

Methods

205 CRT patients (age 65 ± 12 years, 69 % men) were included. At baseline and 6 months echocardiographic studies, exercise testing and laboratory measurements were performed. CRT response was assessed by: ∆LVESV, ∆LV ejection fraction (LVEF), ∆ interventricular mechanical delay, ∆VO2 peak, ∆VE/VCO2, ∆BNP, ∆creatinine, ∆NYHA, and ∆QRS. These were correlated to the occurrence of major adverse cardiac events (MACE) between 6 and 24 months.

Results

MACE occurred in 19 % of the patients (non-ischaemic: 13 %, ischaemic: 24 %). ∆LVESV remained the only surrogate marker for CRT response for the total population and patients with non-ischaemic cardiomyopathy, showing areas under the curve (AUC) of 0.69 and 0.850, respectively. For ischaemic cardiomyopathy, ∆BNP was the best surrogate marker showing an AUC of 0.66.

Conclusion

∆LVESV is an excellent surrogate marker measuring CRT response concerning long-term outcome for non-ischaemic cardiomyopathy. ∆LVESV is not suitable for ischaemic cardiomyopathy in which measuring CRT response remains difficult.  相似文献   

4.

Background

Super-responders to cardiac resynchronisation therapy (CRT) show an exceptional improvement in left ventricular ejection fraction (LVEF). Previous studies showed that apical rocking was independently associated with echocardiographic response to CRT. However, little is known about the association between apical rocking and super-response to CRT.

Objectives

To determine the independent association of LV apical rocking with super-response to CRT in a large cohort.

Methods

A cohort of 297 consecutive heart failure patients treated with primary indication for CRT-D were included in an observational registry. Apical rocking was defined as motion of the left ventricular (LV) apical myocardium perpendicular to the LV long axis. ‘Super-response’ was defined by the top quartile of LVEF response based on change from baseline to follow-up echocardiogram. Best-subset regression analysis identified predictors of LVEF super-response to CRT.

Results

Apical rocking was present in 45 % of patients. Super-responders had an absolute mean LVEF increase of 27 % (LVEF 22.0 % ± 5.7 at baseline and 49.0 % ± 7.5 at follow-up). Apical rocking was significantly more common in super-responders compared with non-super-responders (76 and 34 %, P < 0.001). In univariate analysis, female gender (OR 2.39, 95 % CI 1.38–4.11), lower LVEF at baseline (OR 0.91 95 % CI 0.87–0.95), non-ischaemic aetiology (OR 4.15, 95 % CI 2.33–7.39) and apical rocking (OR 6.19, 95 % CI 3.40–11.25) were associated with super-response. In multivariate analysis, apical rocking was still strongly associated with super-response (OR 5.82, 95 % CI 2.68–12.61). Super-responders showed an excellent clinical prognosis with a very low incidence of heart failure admission, cardiac mortality and appropriate ICD therapy.

Conclusion

Apical rocking is independently associated with super-response to CRT.

Electronic supplementary material

The online version of this article (doi:10.1007/s12471-015-0768-4) contains supplementary material, which is available to authorized users.  相似文献   

5.

Background

Little is known about the effect of cardiac resynchronization therapy (CRT) on endo- and epicardial ventricular activation. Noninvasive imaging of cardiac electrophysiology (NICE) is a novel imaging tool for visualization of both epi- and endocardial ventricular electrical activation.

Methodology/Principal Findings

NICE was performed in ten patients with congestive heart failure (CHF) undergoing CRT and in ten patients without structural heart disease (control group). NICE is a fusion of data from high-resolution ECG mapping with a model of the patient''s individual cardiothoracic anatomy created from magnetic resonance imaging. Beat-to-beat endocardial and epicardial ventricular activation sequences were computed during native rhythm as well as during ventricular pacing using a bidomain theory-based heart model to solve the related inverse problem. During right ventricular (RV) pacing control patients showed a deterioration of the ventricular activation sequence similar to the intrinsic activation pattern of CHF patients. Left ventricular propagation velocities were significantly decreased in CHF patients as compared to the control group (1.6±0.4 versus 2.1±0.5 m/sec; p<0.05). CHF patients showed right-to-left septal activation with the latest activation epicardially in the lateral wall of the left ventricle. Biventricular pacing resulted in a resynchronization of the ventricular activation sequence and in a marked decrease of total LV activation duration as compared to intrinsic conduction and RV pacing (129±16 versus 157±28 and 173±25 ms; both p<0.05).

Conclusions/Significance

Endocardial and epicardial ventricular activation can be visualized noninvasively by NICE. Identification of individual ventricular activation properties may help identify responders to CRT and to further improve response to CRT by facilitating a patient-specific lead placement and device programming.  相似文献   

6.

Objective

The objective of the study was to examine whether cardiac resynchronisation therapy upgrade procedures are more complex and associated with more complications than de novo implantations.

Method

We retrospectively compared 134 upgrade procedures performed between 2006–2012 with a random, equally sized, sample of de novo CRT device implantations in the same period. Procedural data and the occurrence of periprocedural (≤ 30 days) and long-term device-related (≤ 1 year) complications were analysed. Complications with consequences were defined as those in need of adjustment of standard care.

Results

Median time to upgrade was 57 (31–115) months. There were no significant differences in procedure duration, radiation time or total hospitalisation between upgrades and de novo implantations. Perioperative complications occurred in 6.7 % of upgrade patients and in 9.0 % of de novo patients. The most frequently seen complications were phrenic nerve stimulation, coronary sinus dissection and pocket haematoma. Procedure success was comparable (upgrade: 98.5 % versus de novo: 96.3 %). A total of 236 patients completed 1 year of follow-up. Ten (4.2 %) patients had a long-term device-related complication with consequences including phrenic nerve stimulation, lead dislodgement/dysfunction, and infection (upgrade: 3.5 % versus de novo: 4.9 %).

Conclusion

Upgrade procedures are not more complex nor associated with more complications than de novo CRT implantations.  相似文献   

7.

Background

Patients eligible for cardiac resynchronisation therapy (CRT) have an indication for primary prophylactic implantable cardioverter defibrillator (ICD) therapy. However, response to CRT might influence processes involved in arrhythmogenesis and therefore change the necessity of ICD therapy in certain patients.

Method

In 202 CRT-defibrillator patients, the association between baseline variables, 6-month echocardiographic outcome (volume response: left ventricular end-systolic volume decrease < ≥15 % and left ventricular ejection fraction (LVEF) ≤ >35 %) and the risk of first appropriate ICD therapy was analysed retrospectively.

Results

Fifty (25 %) patients received appropriate ICD therapy during a median follow-up of 37 (23–52) months. At baseline ischaemic cardiomyopathy (hazard ratio (HR) 2.0, p = 0.019) and a B-type natriuretic peptide level > 163 pmol/l (HR 3.8, p < 0.001) were significantly associated with the risk of appropriate ICD therapy. After 6 months, 105 (52 %) patients showed volume response and 51 (25 %) reached an LVEF > 35 %. Three (6 %) patients with an LVEF > 35 % received appropriate ICD therapy following echocardiography at ± 6 months compared with 43 patients (29 %) with an LVEF ≤ 35 % (p = 0.001). LVEF post-CRT was more strongly associated to the risk of ventricular arrhythmias than volume response (LVEF > 35 %, HR 0.23, p = 0.020).

Conclusion

Assessing the necessity of an ICD in patients eligible for CRT remains a challenge. Six months post-CRT an LVEF > 35 % identified patients at low risk of ventricular arrhythmias. LVEF might be used at the time of generator replacement to identify patients suitable for downgrading to a CRT-pacemaker.  相似文献   

8.

Introduction

Catheter ablation of longstanding (> 1 year) persistent atrial fibrillation (AF) is associated with poor outcome. This might be due to remodelling and fibrosis formation, mainly located in the posterior left atrial (LA) wall. Therefore, we adopted a thoracoscopic epicardial box isolation of the posterior left atrium using bipolar RF energy with intraoperative testing of conduction block.

Methods and results

Bilateral thoracoscopic box isolation was performed with a bipolar RF clamp. Entrance block was defined as absence of a conducted electrogram within the box, while exit block was confirmed by pacing at 10.0 V/2 ms. Ablation outcome was evaluated after 3, 6, 12 and 24 months with 12-lead ECGs and 24-hour Holter recordings.Twenty-five consecutive patients were included (58 ± 7 years, persistent AF duration 1.8 ± 0.9 years). Entrance block was achieved in all patients and exit block confirmed if sinus rhythm was achieved. After 17 ± 7 months, 76 % of the patients (n = 19) were free of AF recurrence. One patient died within 1 month and was considered an ablation failure. Four patients with AF recurrences regained sinus rhythm with additional catheter ablation or antiarrhythmic drugs.

Conclusions

Treatment of longstanding persistent AF with thoracoscopic epicardial LA posterior box isolation using bipolar RF energy with intraoperative testing of conduction block is feasible and highly effective.  相似文献   

9.

Objective

The purpose of this study was to determine if anodal stimulation accounts for failure to benefit from cardiac resynchronization therapy (CRT) in some patients.

Background

Approximately 30-40% of patients with moderate to severe heart failure do not have symptomatic nor echocardiographic improvement in cardiac function following CRT. Modern CRT devices allow the option of programming left ventricular (LV) lead pacing as LV tip to right ventricular (RV) lead coil to potentially improve pacing thresholds. However, anodal stimulation can result in unintentional RV pacing (anode) instead of LV pacing (cathode).

Methods

Patients enrolled in our center''s CRT registry had an echocardiogram, 6-minute walk (6MW), and Minnesota Living with HF Questionnaire (MLHFQ) pre-implant and 6 months after CRT. Electrocardiograms (12 lead) during RV, LV, and biventricular (BiV) pacing were obtained at the end of the implant in 102 patients. Anodal stimulation was defined as LV pacing QRS morphology on EKG being identical to RV pacing or consistent with fusion with RV and LV electrode capture. LV end systolic volume (LVESV) was measured by echo biplane Simpson''s method and CRT responder was defined as 15% or greater reduction in LVESV.

Results

Of the 102 patients, 46 (45.1%) had the final LV lead pacing configuration programmed LV (tip or ring) to RV (coil or ring). 3 of the 46 subjects (6.5%) had EKG findings consistent with anodal stimulation, not corrected intraoperatively. All anodal stimulation patients were nonresponders to CRT by echo criteria (reduction in LVESV 13.3 ± 0.6%, increase in EF 5.0 ± 1.4%) compared to 46% responders for those without anodal stimulation, (change in LVESV 18.7 ± 25.6%, EF 7.6 ±10.9%). None of the anodal stimulation patients were responders for the 6 minute walk, compared to 32 of 66 (48%) of those without anodal stimulation.

Conclusion

Anodal stimulation is a potential underrecognized and ameliorable cause of poor response to CRT.  相似文献   

10.

Background

For successful cardiac resynchronisation therapy (CRT) a spatial and electrical separation of right and left ventricular electrodes is essential. The spatial distribution of electrical delays within the coronary sinus (CS) tributaries has not yet been identified.

Objective

Electrical delays within the CS are described during sinus rhythm (SR) and right ventricular pacing (RVP). A coordinate system grading the mitral ring from 0° to 360° and three vertical segments is proposed to define the lead positions irrespective of individual CS branch orientation.

Methods

In 13 patients undergoing implantation of a CRT device 6±2.5, (median 5) lead positions within the CS were mapped during SR and RVP. The delay to the onset and the peak of the local signal was measured from the earliest QRS activation or the pacing spike. Fluoroscopic positions were compared to localizations on a nonfluoroscopic electrode imaging system.

Results

During SR, electrical delays in the CS were inhomogenous in patients with or without left bundle branch block (LBBB). During RVP, the delays increased by 44±32 ms (signal onset from 36±33 ms to 95±30 ms; p<0.001, signal peak from 105±44 ms to 156±30 ms; p<0.001). The activation pattern during RVP was homogeneous and predictable by taking the grading on the CS ring into account: (% QRS) = 78−0.002 (grade−162)2, p<0.0001. This indicates that 78% of the QRS duration can be expected as a maximum peak delay at 162° on the CS ring.

Conclusion

Electrical delays within the CS vary during SR, but prolong and become predictable during RVP. A coordinate system helps predicting the local delays and facilitates interindividual comparison of lead positions irrespective of CS branch anatomy.  相似文献   

11.

Objectives

The beneficial effects of cardiac resynchronization therapy (CRT) are thought to result from favorable left ventricular (LV) reverse remodeling, however CRT is only successful in about 70% of patients. Whether response to CRT is associated with a decrease in ventricular arrhythmias (VA) is still discussed controversially. Therefore, we investigated the incidence of VA in CRT responders in comparison with non-responders.

Methods

In this nonrandomized, two-center, observational study patients with moderate-to-severe heart failure, LV ejection fraction (LVEF) ≤35%, and QRS duration >120 ms undergoing CRT were included. After 6 months patients were classified as CRT responders or non-responders. Incidence of VA was compared between both groups by Kaplan-Meier analysis and Cox regression analysis. ROC analysis was performed to determine the aptitude of LVEF cut-off values to predict VA.

Results

In total 126 consecutive patients (64±11years; 67%male) were included, 74 were classified as responders and 52 as non-responders. While the mean LVEF at baseline was comparable in both groups (25±7% vs. 24±8%; P = 0.4583) only the responder group showed an improvement of LVEF (36±6% vs. 24±7; p<0.0001) under CRT. In total in 56 patients VA were observed during a mean follow-up of 28±14 months, with CRT responders experiencing fewer VA than non-responders (35% vs. 58%, p<0.0061). Secondary preventive CRT implantation was associated with a higher likelihood of VA. As determined by ROC analysis an increase of LVEF by >7% was found to be a predictor of a significantly lower incidence of VA (AUC = 0.606).

Conclusions

Improvement of left ventricular function under cardiac resynchronization therapy goes along with a reduced incidence of ventricular arrhythmia.  相似文献   

12.

Purpose

Since several large trials have proven the effectiveness of implantable cardioverter-defibrillators (ICDs) in patients with left ventricular dysfunction, disadvantages have become more apparent. As the prognosis of patients with cardiovascular diseases is improving, assessment of ICD patients and re-evaluation of the current guidelines is mandatory. We aimed to evaluate differences in mortality and occurrence of (in)appropriate shocks in ICD patients with coronary artery disease (CAD) or dilated cardiomyopathy (DCM).

Methods

In a large teaching hospital, all consecutive patients with systolic dysfunction due to CAD or DCM who received an ICD with and without resynchronisation therapy, were collected in a database.

Results

A total of 320 consecutive patients (age 67 ± 10 years) were classified as CAD patients and 178 (63 ± 11 years) as DCM patients. Median follow-up was 40 months (interquartile range [IQR] 23─57 months). All–cause mortality was 14 % (CAD 15 % vs DCM 13 %). Appropriate shocks occurred in 13 % of all patients (CAD 15 % vs DCM 11 %, p = 0.12) and inappropriate shocks occurred in 10 % (CAD 8 % vs DCM 12 %, p = 0.27). Multivariate analysis demonstrated impaired left ventricular ejection fraction, QRS >120, age ≥75 years and low estimated glomerular filtration rate as predictors for all-cause mortality. Predictors for inappropriate shocks were permanent and paroxysmal atrial fibrillation.

Conclusion

Mortality rates were similar in patients with CAD and DCM who received an ICD. Furthermore, no differences were found in the occurrence of appropriate and inappropriate ICD interventions between these patient groups.  相似文献   

13.

Background

Hepatocyte growth factor (HGF) is one of the major angiogenic factors being studied for the treatment of ischemic heart diseases. Our previous study demonstrated adenovirus-HGF was effective in myocardial ischemia models. The first clinical safety study showed a positive effect in patients with severe and diffused triple coronary disease.

Methods

12 Pigs were randomized (1∶1) to receive HGF, which was administered as five injections into the infarcted myocardium, or saline (control group). The injections were guided by EnSite NavX left ventricular electroanatomical mapping.

Results

The catheter-based injections caused no pericardial effusion, malignant arrhythmia or death. During mapping and injection, alanine aminotransferase, aspartate aminotransferase, blood urea nitrogen, serum creatinine and creatine kinase-MB levels have no significant increase as compared to those before and after the injection in HGF group(P>0.05). HGF group has high HGF expression with Western blot, less myocardial infarct sizes by electroanatomical mapping (HGF group versus after saline group, 5.28±0.55 cm2 versus 9.06±1.06 cm2, P<0.01), better cardiac function with Gated-Single Photon Emission Computed Tomography compared with those in saline group. Histological, strongly increased lectin–positive microvessels and microvessel density were found in the myocardial ischemic regions in HGF group.

Conclusion

Intramyocardial injection guided by NavX system provides a method of feasible and safe percutaneous gene transfer to myocardial infarct regions.  相似文献   

14.

Objective

Implantable cardioverter defibrillators (ICD) and cardiac resynchronisation therapy (CRT) have substantially improved the survival of patients with cardiomyopathy. Eligibility for this therapy requires a left ventricular ejection fraction (LVEF) <35 %. This is largely based on studies using echocardiography. Cardiac magnetic resonance imaging (CMR) is increasingly utilised for LVEF assessment, but several studies have shown differences between LVEF assessed by CMR and echocardiography. The present study compared LVEF assessment by CMR and echocardiography in a heart failure population and evaluated effects on eligibility for device therapy.

Methods

152 patients (106 male, mean age 65.5 ± 9.9 years) referred for device therapy were included. During evaluation of eligibility they underwent both CMR and echocardiographic LVEF assessment. CMR volumes were computed from a stack of short-axis images. Echocardiographic volumes were computed using Simpson’s biplane method.

Results

The study population demonstrated an underestimation of end-diastolic volume (EDV) and end-systolic volume (ESV) by echocardiography of 71 ± 53 ml (mean ± SD) and 70 ± 49 ml, respectively. This resulted in an overestimation of LVEF of 6.6 ± 8.3 % by echocardiography compared with CMR (echocardiographic LVEF 31.5 ± 8.7 % and CMR LVEF 24.9 ± 9.6 %). 28 % of patients had opposing outcomes of eligibility for cardiac device therapy depending on the imaging modality used.

Conclusion

We found EDV and ESV to be underestimated by echocardiography, and LVEF assessed by CMR to be significantly smaller than by echocardiography. Applying an LVEF cut-off value of 35 %, CMR would significantly increase the number of patients eligible for device implantation. Therefore, LVEF cut-off values might need reassessment when using CMR.  相似文献   

15.

Purpose

Left ventricular (LV) trabeculation may be more pronounced in ethnic African than in Caucasian (European) athletes, leading to possible incorrect diagnosis of left ventricular non-compaction cardiomyopathy (LVNC). This study investigates ethnic differences in LV hypertrabeculation amongst elite athletes with cardiac magnetic resonance (CMR) and electrocardiography (ECG).

Methods

38 elite male football (soccer) players (mean age 23.0, range 19–34 years, 28/38 European, 10/38 African) underwent CMR and ECG. Hypertrabeculation was assessed using the ratio of non-compacted to compacted myocardium (NC/C ratio) on long-axis and short-axis segments. ECGs were systematically rated.

Results

No significant differences were seen in ventricular volumes, wall mass or E/A ratio, whereas biventricular ejection fraction (EF) was significantly lower in African athletes (European/African athletes LVEF 55/50 %, p = 0.02; RVEF 51/48 %, p = 0.05). Average NC/C ratio was greater in African athletes but only significantly at mid-ventricular level (European/African athletes: apical 0.91/1.00, p = 0.65; mid-ventricular 0.89/1.45, p < 0.05; basal 0.40/0.46, p = 0.67). ECG readings demonstrated no significant group differences, and no correlation between ECG anomalies and hypertrabeculation.

Conclusions

A greater degree of LV hypertrabeculation is seen in healthy African athletes, combined with biventricular EF reduction at rest. Recognition of this phenomenon is necessary to avoid misdiagnosis of LVNC.  相似文献   

16.

Aims

To determine the frequency, characteristics and risk factors of cardiac device infections in the Isala Hospital.

Methods

We retrospectively studied all patients who underwent cardiac device procedures performed in the cardiac catheterisation lab and the operating room from 2010 to 2012. All patients who developed a cardiac device infection were reviewed for its characteristics.

Results

31/2026 patients developed a cardiac device infection (1.5 %). One (3.2 %) patient died within 30 days of hospitalisation. Device infection rates for procedures in the catheterisation lab and operating room were similar (p = 0.60). Positive cultures were present in 27/31 (87 %) cases. These consisted predominantly of micro-organisms that are part of the skin flora (84 %). The mean time between device procedure and infection was 14 ± 21 months (range 0–79). Cardiac device infection was significantly associated with device revision, (65 % were revisions in patients with device infection vs. 30 % revisions in patients without device infection, p = 0.011) and placement of a left ventricular lead in pacemaker implantations (59 % of patients with vs. 51 % of patients without device infection, p < 0.001).

Conclusion

The frequency of cardiac device infection was 1.5 % with a mortality of 3.2 % within 30 days, which is lower compared with other registries. Cardiac device infections were associated with device revisions and placement of left ventricular leads in pacemaker implantations.  相似文献   

17.

Background

There is increasing interest in utilising novel markers of cardiovascular disease risk in patients with chronic heart failure (HF). Recently, it was shown that alpha-1-antichymotrypsin (ACT), an acute-phase protein and major inhibitor of cathpesin G, plays a role in the pathophysiology of HF and may serve as a marker for myocardial distress.

Objective

To assess whether ACT is independently associated with long-term mortality in chronic HF patients.

Methods

ACT plasma levels were categorised into quartiles. Survival times were analysed using Kaplan-Meier curves and Cox proportional hazards regression, without and with correction for clinically relevant risk factors, including sex, age, duration of HF, kidney function (MDRD), ischaemic HF aetiology and NT-proBNP.

Results

Twenty healthy individuals and 224 patients (mean age 71 years, 72 % male, median HF duration 1.6 years) with chronic HF were included. In total, 159 (71 %) patients died. The median survival time was 5.3 (95 % CI 4.5–6.1) years. ACT was significantly elevated in patients (median 433 μg/ml, IQR 279–680) in comparison with controls (median 214 μg/ml, IQR 166–271; p < 0.001). Cox regression analysis demonstrated that ACT was not independently related to long-term mortality in chronic HF patients (crude HR = 1.03, 95 % CI 0.75–1.41, p = 0.871; adjusted HR = 1.12, 95 % CI 0.78–1.60, p = 0.552), which was confirmed by Kaplan-Meier curves.

Conclusion

ACT levels are elevated in chronic HF patients, but no independent association with long-term mortality can be established.  相似文献   

18.

Background

Post-implantation therapies to optimize cardiac resynchronization therapy (CRT) focus on adjustments of the atrio-ventricular (AV) delay and ventricular-to-ventricular (VV) interval. However, there is little consensus on how to achieve best resynchronization with these parameters. The aim of this study was to examine a novel combination of doppler echocardiography (DE) and three-dimensional echocardiography (3DE) for individualized optimization of device based AV delays and VV intervals compared to empiric programming.

Methods

25 recipients of CRT (male: 56%, mean age: 67 years) were included in this study. Ejection fraction (EF), the primary outcome parameter, and left ventricular (LV) dimensions were evaluated by 3DE before CRT (baseline), after AV delay optimization while pacing the ventricles simultaneously (empiric VV interval programming) and after individualized VV interval optimization. For AV delay optimization aortic velocity time integral (AoVTI) was examined in eight different AV delays, and the AV delay with the highest AoVTI was programmed. For individualized VV interval optimization 3DE full-volume datasets of the left ventricle were obtained and analyzed to derive a systolic dyssynchrony index (SDI), calculated from the dispersion of time to minimal regional volume for all 16 LV segments. Consecutively, SDI was evaluated in six different VV intervals (including LV or right ventricular preactivation), and the VV interval with the lowest SDI was programmed (individualized optimization).

Results

EF increased from baseline 23±7% to 30±8 (p<0.001) after AV delay optimization and to 32±8% (p<0.05) after individualized optimization with an associated decrease of end-systolic volume from a baseline of 138±60 ml to 115±42 ml (p<0.001). Moreover, individualized optimization significantly reduced SDI from a baseline of 14.3±5.5% to 6.1±2.6% (p<0.001).

Conclusions

Compared with empiric programming of biventricular pacemakers, individualized echocardiographic optimization with the integration of 3-dimensional indices into the optimization protocol acutely improved LV systolic function and decreased ESV and can be used to select the optimal AV delay and VV interval in CRT.  相似文献   

19.

Background

Alcohol septal ablation (ASA) provides symptomatic relief in most but not all patients with hypertrophic obstructive cardiomyopathy (HOCM). Therefore we investigated predictors of outcome after ASA.

Methods

Clinical, echocardiographic, angiographic and procedural characteristics were analysed in 113 consecutive patients. Successful ASA was defined as NYHA ≤ 2 with improvement of at least 1 class combined with a resting gradient < 30 mmHg and provoked gradient < 50 mmHg at 4-month follow-up.

Results

In 37 patients ASA was not successful. In multivariate analysis, baseline gradient (OR 1.06 (1.01–1.11) per 5 mmHg, p = 0.024) and distance to the ablated septal branch (OR 1.09 (1.03–1.16) per mm, p = 0.004) were predictors of unsuccessful outcome. The combined presence of a non-ablated septal branch and a distance ≥ 19 mm to the ablated branch was a predictor of unsuccessful outcome (OR 5.88 (2.06–16.7), p < 0.001).

Conclusions

Baseline gradient and a greater distance from the origin of the left anterior descending artery to the ablated septal branch combined with a non-ablated proximal septal branch are associated with an unsuccessful outcome after ASA.  相似文献   

20.

Background

Blood donor screening leads to large numbers of new diagnoses of Trypanosoma cruzi infection, with most donors in the asymptomatic chronic indeterminate form. Information on electrocardiogram (ECG) findings in infected blood donors is lacking and may help in counseling and recognizing those with more severe disease.

Objectives

To assess the frequency of ECG abnormalities in T.cruzi seropositive relative to seronegative blood donors, and to recognize ECG abnormalities associated with left ventricular dysfunction.

Methods

The study retrospectively enrolled 499 seropositive blood donors in São Paulo and Montes Claros, Brazil, and 483 seronegative control donors matched by site, gender, age, and year of blood donation. All subjects underwent a health clinical evaluation, ECG, and echocardiogram (Echo). ECG and Echo were reviewed blindly by centralized reading centers. Left ventricular (LV) dysfunction was defined as LV ejection fraction (EF)<0.50%.

Results

Right bundle branch block and left anterior fascicular block, isolated or in association, were more frequently found in seropositive cases (p<0.0001). Both QRS and QTc duration were associated with LVEF values (correlation coefficients −0.159,p<0.0003, and −0.142,p = 0.002) and showed a moderate accuracy in the detection of reduced LVEF (area under the ROC curve: 0.778 and 0.790, both p<0.0001). Several ECG abnormalities were more commonly found in seropositive donors with depressed LVEF, including rhythm disorders (frequent supraventricular ectopic beats, atrial fibrillation or flutter and pacemaker), intraventricular blocks (right bundle branch block and left anterior fascicular block) and ischemic abnormalities (possible old myocardial infarction and major and minor ST abnormalities). ECG was sensitive (92%) for recognition of seropositive donors with depressed LVEF and had a high negative predictive value (99%) for ruling out LV dysfunction.

Conclusions

ECG abnormalities are more frequent in seropositive than in seronegative blood donors. Several ECG abnormalities may help the recognition of seropositive cases with reduced LVEF who warrant careful follow-up and treatment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号