首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In a biomass assay based on adenosine 5(')-triphosphate (ATP) bioluminescence, extracellular ATP is removed; then intracellular ATP is extracted from the microorganism by an ATP extractant and subsequently reacted with luciferase. To provide a highly sensitive assay, the concentration of benzalkonium chloride (BAC) in the ATP extractant was optimized by using a mutant luciferase resistant to BAC. The use of 0.2% BAC, which was acceptable for the luciferase, simultaneously achieved the maximum extraction of intracellular ATP from microorganisms and the inactivation of the ATP-eliminating enzymes for removal of extracellular ATP. The detection limit (blank+3 SD) for ATP was 1.8x10(-14)M (1.8x10(-18)mol/assay) in the presence of the ATP extractant with coefficients of variation of 0.7 to 6.3%. The reagent system coupled with the ATP-eliminating enzymes allowed for the detection of 93 colony-forming units (CFU)/ml of Escherichia coli ATCC 25922, 170CFU/ml of Pseudomonas aeruginosa ATCC 27853, 170CFU/ml of Proteus mirabilis ATCC 29906, 68CFU/ml of Staphylococcus aureus ATCC 25923, and 7.7CFU/ml of Bacillus subtilis ATCC 6051. The yeast cell of Saccharomyces cerevisiae IFO 10217 could be detected at 1CFU/ml. With 54 kinds of microorganisms, the average ATP extraction efficiency compared to the trichloroacetic acid extraction method was 81.0% in 24 strains among gram-negative bacteria, 99.4% in 13 strains among gram-positive bacteria, and 97.0% in 17 strains among yeast. The ATP contents of the gram-negative bacteria, gram-positive bacteria, and yeasts ranged from 0.40 to 2.70x10(-18)mol/CFU (mean=1.5x10(-18)mol/CFU), from 0.41 to 16.7x10(-18)mol/CFU (mean=5.5x10(-18)mol/CFU), and from 0.714 to 54.6x10(-16)mol/CFU (mean=8.00x10(-16)mol/CFU), respectively.  相似文献   

2.
A rapid (30-35 min) bioluminescence assay of total bacterial contamination (TBC) of raw milk was optimized. This method includes incubation of milk samples in the presence of Neonol-10 and medical purity grade pancreatin with further removal of nonbacterial ATP by filtration through a membrane filter, cell disruption by treatment with dimethyl sulfoxide, and measurement of ATP concentration in a reaction with the bioluminescent reagent Immolum. The TBC detection threshold is 0.5 x 10(5) colony-forming units (CFU) per ml milk. Coefficients of correlation between the standard plate count method and bioluminescence assay (R) and residual standard deviations (Sxy) in raw milk samples (n = 140) were 0.83 and 0.54, respectively. In sterilized milk samples artificially contaminated with pure cultures of the main representatives of milk microflora (coli-forms, Staphylococcus aureus, Streptococcus thermophilus, and Streptococcus group D), these values were 0.89-0.99 and 0.09-0.29, respectively. The specific content of ATP was found to be (0.8 +/- 0.1) x 10(-18) mol/CFU in coli-forms; (12.0 +/- 8.1) x 10(-18) mol/CFU in S. aureus; (35.2 +/- 16.9) x 10(-18) mol/CFU in S. thermophilus; and (42.5 +/- 1.3) x 10(-18) in Streptococcus group D.  相似文献   

3.
Resident and thioglycollate-elicited macrophages maintained in culture for 24 h contain approximately 5 x 10(-16) and 12 x 10(-16) mol of ATP per cell, respectively. During particle ingestion, the levels of ATP in these cells did not change. However, the specific activity of ATP extracted from macrophages labeled with [32P]Pi during phagocytosis was 40% lower than ATP extracted from control cells. These results suggested that macrophages contain a high energy phosphate reservoir, in addition to the ATP pool(s). A search for such a reservoir led to the identification of creatine phosphate in both resident and thioglycollate-elicited macrophages at concentrations that are in 3- to 5-fold-molar excess over ATP. Creatine phosphate levels in phagocytosing resident macrophages decreased by 45%, while creatine phosphate levels in phagocytosing thioglycollate-elicited macrophages did not change. Creatine phosphate turnover was measured in macrophages prelabeled with [14C]creatine. Over 90% of the intracellular label was in the form of creatine phosphate. During phagocytosis, there was a 40% decrease in intracellular [14C]creatine phosphate in both resident and thioglycollate-elicited macrophages. These results indicate that creatine phosphate turns over more rapidly during phagocytosis and replenishes the ATP consumed.  相似文献   

4.
研究了ATP生物荧光检测法与国标法《GB4789.2-2010食品卫生微生物学检验菌落总数测定》检测鸡蛋壳表面细菌总数的相关性。采用ATP生物荧光检测法和国标法对40个混合样品表面细菌总数进行检测,以log CFU/个蛋壳为横坐标(x),以logRLU/个蛋壳为纵坐标(y),分别进行线性、对数、乘幂、指数拟合。结果表明,ATP荧光检测法与国标法检测结果 Pearson相关系数为0.912,线性模型y=0.7306x-1.0041(R2=0.8322)拟合度较高。该试验结果为ATP荧光检测法在鸡蛋壳表面细菌总数快速检测中应用的可行性提供了依据。  相似文献   

5.
Capillary zone electrophoresis was employed for the determination of lactate using end-column amperometric detection at a carbon fiber bundle microdisk electrode. The optimum conditions of separation and detection are 3.6 x 10(-3) mol/l Na(2)HPO(4)-1.4 x 10(-3) mol/l NaH(2)PO (pH 7.2) for the buffer solution, 18 kV for the separation voltage and 1.60 V versus the saturated calomel electrode for the detection potential. The limit of detection is 7.6 x 10(-7) mol/l or 1.7 fmol (S/N=3) and the linear range is 1.7 x 10(-6)-8.2 x 10(-4) mol/l for the injection voltage of 6 kV and injection time of 5 s. The RSD is 1.8% for the migration time and 3.3% for the electrophoretic peak current. The method was applied to the determination of lactate in human saliva. The recovery of the method is between 95 and 109%.  相似文献   

6.
A simple method for determination of perphenazine by capillary zone electrophoresis with amperometric detection is described. The optimum conditions of separation and detection are 1.50 x 10(-3) mol/l Na(2)B(4)O(7)-1.0 x 10(-3) mol/l NaOH (pH 9.9) for the buffer solution, 18 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, and 0.80 V versus saturated calomel electrode for the detection potential, respectively. The limit of detection is 5.0 x 10(-8) mol/l or 44 amol (S/N=3). The linear range of the calibration curve is 1.00 x 10(-7) to 1.00 x 10(-4) mol/l. The relative standard deviation is 1.5% for the migration time and 2.9% for the electrophoretic current at peak maximum. The method is applied to the determination of perphenazine in human urine.  相似文献   

7.
A novel bioluminescent enzymatic cycling assay for ATP and AMP with concomitant use of firefly luciferase and pyruvate orthophosphate dikinase (PPDK) was developed. In this system, AMP and pyrophosphate produced from ATP by firefly luciferase were converted back into ATP by PPDK. This resulted in constant luminescence once the stable phase had been reached. Background luminescence of the reagent was reduced with adenosine phosphate deaminase by degrading ATP and AMP in the reagent. The maximum recycling ratio calculated from the integrated luminescence value was 2.64 cycles/min. The measurable ranges for ATP and AMP were equal and were between 4 x 10(-13) and 4 x 10(-17) mol/assay. The amount of yeast RNA could be estimated in the range of 1 x 10(-8) to 1 x 10(-12) g/assay by estimating the amount of AMP resulting from the degradation of RNA with nuclease P1. Various food samples were subjected to measurement of the amount of ATP + AMP + RNA to provide an index for hygiene monitoring. For beef extract, sensitivity was improved by more than 20 million compared to the previous methods relying only on the amount of ATP as an index.  相似文献   

8.
Capillary electrophoresis (CE) was employed to analyze lactate dehydrogenase (LDH) in human erythrocytes using an amperometric detector with a carbon fiber micro-disk bundle electrode. LDH activity was measured by determining the amount of NADH generated by LDH through a enzyme-catalyzed reaction between NAD(+) and lithium lactate. The factors influencing the enzyme-catalyzed reaction, separation and detection were examined and optimized. The following conditions were suitable for the determination of LDH: running buffer, 5.0 x 10(-2)mol/l Tris-HCl (pH 7.5); separation voltage, 20.0 kV; detection potential, 1.00 V (versus saturated calomel electrode (SCE)). The conditions of enzyme-catalyzed reaction were: reaction buffer, 5.0 x 10(-2)mol/l Tris-HCl (pH 9.3); substrates, 5.0 x 10(-2)mol/l lithium lactate and 5.0 x 10(-3)mol/l NAD(+); reaction time, 10 min. The concentration limit of detection (LOD) of the method was 0.017 U/ml at a signal-to-noise (S/N) ratio of 3, which corresponded to 1.10 x 10(-10)mol/l, and the mass LOD was 2 x 10(-20)mol. The linear dynamic range was 0.039-4.65 U/ml for the injection voltage of 5.0 kV and injection time of 10s. The relative standard deviation (R.S.D.) was 0.85% for the migration time and 1.8% for the electrophoretic peak area. The method was applied to determine LDH in human erythrocytes. The recovery of the method was between 98 and 101%.  相似文献   

9.
A novel CL method for the determination of tannic acid (TA) was established based on TA inhibition of the chemiluminescence (CL) emission of the luminol-hydrogen peroxide CL system catalysed by tetrasulphonated manganese phthalocyanine (MnTSPc) under alkaline conditions. The peak height is proportional to the natural logarithm of concentration of TA in the range 1.0 x 10(-7)-3.0 x 10(-10) mol/L with a detection limit of 5.6 x 10(-11) mol/L and the relative standard deviation was 2.5% for the determination of 1.0 x 10(-8) mol/L TA (n = 11). The proposed method has been successfully applied to the determination of TA in Chinese gall and industrial wastewater.  相似文献   

10.
Capillary zone electrophoresis was employed for the determination of midecamycin using an end-column amperometric detection with a carbon fiber micro-disk bundle electrode at a constant potential of +1.15 V vs. saturated calomel electrode. The optimum conditions of separation and detection are 1.00x10(-3) mol l(-1) Na(2)HPO(4)-3.49x10(-4) mol l(-1) NaOH (pH 11.4) for the buffer solution, 20 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, respectively. The limit of detection is 5.0x10(-7) mol l(-1) or 0.41 fmol (S/N=3). The linear range of the calibration curve is 1.00x10(-6)-1.00x10(-3) mol l(-1). The relative standard deviation is 1.4% for the migration time and 4.9% for the electrophoretic peak current. The method could be applied to the determination of midecamycin in human urine. In this case, a separation voltage of 14 kV was used.  相似文献   

11.
In this paper, we attempt to develop a sensitive detection method for glucose with the combination of the unique optical property of quantum dots and the specificity of enzymatic reactions. With glucose and hydroquinone as substrates, benzoquinone that intensively quenches the photoluminescence of quantum dots can be produced via the catalysis of bienzyme (glucose oxidase and horseradish peroxidase) system. A relatively low detection limit of 1.0x10(-8)mol/L can be achieved. Two linear ranges from 1.0x10(-6) to 1.5x10(-4)M and from 1.5x10(-4) to 1.0x10(-3)M were obtained. For the detection of 1.0x10(-4)M glucose, six replicative measurements showed the reproducibility (R.S.D.) of 4.43%. The quantum dots-enzymes system possesses advantages of simple procedure without modification of quantum dots or immobilization of enzymes, low cost, high sensitivity and short detection times within several minutes.  相似文献   

12.
A method of indirectly measuring pyruvic acid (PA) by capillary electrophoresis with amperometric detection is proposed for the first time. It is based on the oximation reaction between PA and hydroxylamine (NH(2)OH), and the quantification of PA was performed by direct and sensitive amperometric detection of excessive NH(2)OH after the oximation reaction. This method displayed a good sensitivity, and the detection limits of NH(2)OH and PA are 1.76 x 10(-7) and 3.88 x 10(-7)mol/L, respectively at S/N=3. The linear relationship between the peak current and PA concentration is exhibited over the range from 4 x 10(-6) to 1 x 10(-4)mol/L. This method has been applied to determine PA in rat plasma with satisfactory results.  相似文献   

13.
Measurement of oxidative stress in human liver by EPR spin-probe technique   总被引:1,自引:0,他引:1  
A method for the measurement of reactive oxygen species (ROS) in human hepatic tissue has been developed. The method is based on the EPR detection of the nitroxide radical produced by reaction of the hydroxylamine spin-probe bis(1-hydroxy-2,2,6,6-tetramethyl-4-piperidinyl)decandioate with ROS generated under pseudo-physiologic conditions in fine needle biopsies of healthy (10 controls) and diseased (22 patients) human liver. Measures of malonaldehyde in 9 liver biopsies (3 controls and 6 patients) have also been obtained by high pressure liquid chromatography and values parallel those obtained by the spin-probe technique. The amount of ROS found in healthy human liver (median = 1.8 x 10(-11) mol/mg) was significantly lower than values found in liver affected by hepatitis B (median=5.8 x 10(-10) mol/mg; p < 0.02) or by hepatitis C (median = 2.7 x 10(-9) mol/mg; p < 0.003) as well as compared to some other non-viral liver diseases (NVLD): autoimmune hepatitis, primary biliary cirrhosis, primary schlerosing cholangitis (median = 9.8 x 10(-9) mol/mg; p < 0.005). NVLD also showed significantly higher ROS levels compared to hepatitis B (p < 0.04) and hepatitis C (p < 0.04). The mechanism, potentiality and limitations of our method are discussed.  相似文献   

14.
A new fluorescent reagent, 1,5-bis(4,6-dichloro-1,3,5-triazinylamino)naphthalene, containing two active chlorines, was synthesized by a one-step reaction. Under the optimum conditions for the determination of dopamine, the enhanced fluorescence intensity is proportional to the dopamine concentration. The fluorescence intensity was measured at lambda(ex/em) = 400/460 nm, with and without dopamine. The linear range and detection limit for the determination of dopamine were 1.0 x 10(-7) mol/L-5.0 x 10(-5) mol/L and 4.0 x 10(-8) mol/L. This method is simple, practical, can afford good precision and accuracy and can be successfully applied to assess dopamine in injections and human serum samples.  相似文献   

15.
A novel enzymatic ligand binding assay for biotin and its benzodiazepine conjugate is based on their binding to horseradish peroxidase-avidin conjugate (A-P) followed by the uptake of biotin-unsaturated A-P onto polystyrene beads coated with biotin-BSA. The detection limit is 1.3 x 10(-16) mol per tube (300 microL) with a 3.3 x 10(-12) M A-P solution and varies with the conjugate concentration employed. The coefficient of variation for 10 repetitive assays of 10(-15) mol of biotin is 6.22%.  相似文献   

16.
Hypericin and hypocrellin are potential antiviral and antineoplastic agents with multiple modes of light-induced biological activity connected with a production of singlet oxygen and/or excited-state proton transfer and consequent pH drop formation in the drugs environment. In present work light-induced cytotoxicity of hypericin and hypocrellin and mechansim of cell death (apoptosis or necrosis) on human leukemic cell line HL-60 was studied. As a mean for apoptosis detection we used poly (ADP-ribose) polymerase (PARP) as a sensitive marker of early stages of apoptosis. Our results show that exposition of HL-60 cells to hypericin (1 x 10(-5) mol x l(-1)) for 4 hours has no effect on PARP cleavage. However, after 24 and 48 hours of illumination there is evident that hypericin in this concentration cleaved PARP (116 kDa) into two fragments (85 and 25 kDa). Contrary to hypericin, hypocrellin in concentration 1 x 10(-5) mol x l(-1) after 4 hours of illumination cleaved PARP into two fragments typical for apoptosis. In lower concentration (1 x 10(-6) mol x l(-1)) hypocrellin possess also significant cytotoxic activity. Because we detected no fragmentation of PARP in all observed time periods we suggest that cytotoxic effect of hypocrellin in this concentration is due to induction of necrosis. Our results support the hypotesis that the hypericin and hypocrellin has similar mechanism of action and illumination increases cytotoxic effect of both agents.  相似文献   

17.
The fabrication and application of a novel electrochemical detection (ED) method with the functionalized multi-wall carbon nanotubes (MWNTs) chemically modified electrode (CME) for liquid chromatography (LC) were described. The electrochemical behaviors of dopamine (DA) and other monoamine neurotransmitters at the CME were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The results indicated that the CME exhibited efficient electrocatalytic effects on the current responses of monoamine neurotransmitters and their metabolites with high sensitivity, high stability and long-life activity. In LC-ED, DA, norepinephrine (NE), 3-methoxy-4-hydroxyphenylglycol (MHPG), 3,4-dihydroxyphenylacetic acid (DOPAC), 5-hydroxytryptamine (5-HT), 5-hydroxyindoleacetic acid (5-HIAA) and homovanillic acid (HVA) had good and stable current responses at the CME. The linear ranges of seven analytes were over four orders of magnitude and the detection limits were 2.5 x 10(-10) mol/l for DA, 2.5 x 10(-10) mol/l for NE, 5.0 x 10(-10) mol/l for MHPG, 3.0 x 10(-10) mol/l for DOPAC, 3.5 x 10(-10) mol/l for 5-HT, 6.0 x 10(-10) mol/l for 5-HIAA, 1.25 x 10(-9) mol/l for HVA. The application of this method coupled with microdialysis sampling for the determination of monoamine neurotransmitters and their metabolites in Parkinsonian patients' cerebrospinal fluid was satisfactory.  相似文献   

18.
A method for the direct determination of ascorbic acid (AA) in individual rat hepatocyte based on capillary electrophoresis (CE) coupled with electrochemical detection (ECD) using a new kind of homemade carbon fiber micro-disk bundle electrode has been described. Individual rat hepatocytes were injected into a fused-silica capillary with an inner diameter of 25 microm, and lysed by 0.1% sodium dodecylsulfate (SDS) as cell lysis solution. The following conditions were suitable for the determination of AA: running buffer, 1.83 x 10(-2) mol/l Na2HPO4-1.70 x 10(-3) mol/l NaH2PO4 (pH 7.8); separation voltage, 20.0 kV; detection potential, 0.80 V (vs. saturated calomel electrode (SCE)). The concentration limit of detection (LOD) of the method was 1.7 x 10(-6) mol/l at a signal-to-noise (S/N) ratio of 3, and the mass LOD was 3.0 fmol. The linear dynamic range was from 5.0 x 10(-6) to 5.0 x 10(-4) mol/l with a correlation coefficient of 0.9962 for the injection voltage of 5.0 kV and injection time of 10s. The relative standard deviation (R.S.D.) was 0.85% for the migration time and 1.8% for the peak current. This method was successfully applied to AA determination in rat hepatocyte. The recovery was between 91% and 97%, and the amount of AA in single rat hepatocyte ranged from 28 to 63 fmol.  相似文献   

19.
The reaction of soluble manganese (IV) with sulphite in acidic condition was found to elicit weak chemiluminescence (CL). The CL signal was remarkably enhanced in the presence of three fluoroquinolones, viz. norfloxacin, ofloxacin and ciprofloxacin. Based on these observations, a new flow-injection CL method was developed for the determination of these fluoroquinolones. The method allows determination in the range 5.0 x 10(-8)-1.0 x 10(-6) mol/L for norfloxacin, 1.0 x 10(-7)-8.0 x 10(-6) mol/L for ofloxacin and 1.0 x 10(-7)-3.0 x 10(-5) mol/L for ciprofloxacin, with detection limits of 3 x 10(-8) mol/L, 5 x 10(-8) mol/L and 3 x 10(-8) mol/L, respectively. The method was applied to the determination of fluoroquinolones in pharmaceutical preparations.  相似文献   

20.
A new spectrofluorimetric method was developed for the determination of trace amounts of 5-hydroxytryptamine (5-HT). Using chlorosulphonylthenoyltrifluoroacetone (CTTA)-europium (Eu(3+)) ion as a fluorescent probe in a buffer solution at pH 11.0, 5-HT can remarkably enhance the fluorescence intensity of the CTTA-Eu(3+) complex at lambda = 612 nm; the enhanced fluorescence intensity of Eu(3+) is proportional to the concentration of 5-HT. Optimum conditions for the determination of 5-HT were also investigated. The linear range and detection limit for the determination of 5-HT were 1.0 x 10(-7)-1.2 x 10(-5) mol/L and 8.5 x 10(-8) mol/L, respectively. This method is simple, practical and relatively free of interference from coexisting substances, and can be applied to assess 5-HT in urine samples.  相似文献   