首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
3.

Purpose

To explore whether alterations in intraocular pressure (IOP) affect vein pulsation properties using ophthalmodynamometric measures of vein pulsation pressure.

Patients and Methods

Glaucoma patients had two retinal vein pulsation pressure (VPP) measurements from upper and lower hemiveins performed by ophthalmodynamometry at least 3 months apart. All subjects had VPP and IOP recorded at two visits, with standard automated perimetry, central corneal thickness (CCT) recorded at the initial visit. Where venous pulsation was spontaneous ophthalmodynamometry could not be performed and VPP was considered equal to IOP. Change in VPP was calculated and binarized with reduction in pressure scored 1 and no change or increase scored as 0. Data analysis used a mixed logistic regression model with change in VPP as response variable and change in IOP, visual field loss (mean deviation), CCT and time interval as explanatory variables.

Results

31 subjects (20 females) with mean age 60 years (sd 11) were examined with change in VPP being significantly associated with change in IOP (odds ratio 1.6/mmHg, 95% CI 1.2 to 2.1 in the glaucoma patients but not suspect patients (p = 0.0005).

Conclusion

Change in VPP is strongly associated with change in IOP such that a reduced intraocular pressure is associated with a subsequent reduction in VPP. This indicates that reduced IOP alters some retinal vein properties however the nature and time course of these changes is not known.  相似文献   

4.
5.
6.

Background

Noninvasive evaluation of central venous pressure (CVP) can be achieved by assessing the Jugular Venous Pressure (JVP), Peripheral Venous Collapse (PVC), and ultrasound visualization of the inferior vena cava. The relative accuracy of these techniques compared to one another and their application by trainees of varying experience remains uncertain. We compare the application and utility of the JVP, PVC, and handheld Mini Echo amongst trainees of varying experience including a medical student, internal medicine resident, and cardiology fellow. We also introduce and validate a new physical exam technique to assess central venous pressures, the Anthem sign.

Methods

Patients presenting for their regularly scheduled echocardiograms at the hospital echo department had clinical evaluations of their CVP using these non-invasive bedside techniques. The examiners were blinded to the echo results, each other''s assessments, and patient history; their CVP estimates were compared to the gold standard level 3 echo-cardiographer''s estimates at the completion of the study.

Results

325 patients combined were examined (mean age 65, s.d. 16 years). When compared to the gold standard of central venous pressure by a level 3 echocardiographer, the JVP was the most sensitive at 86%, improving with clinical experience (p<0.01). The classic PVC technique and Anthem sign had better specificity compared to the JVP. Mini Echo estimates were comparable to physical exam assessments.

Conclusions

JVP evaluation is the most sensitive physical examination technique in CVP assessments. The PVC techniques along with the newly described Anthem sign may be of value for the early learner who still has not mastered the art of JVP assessment and in obese patients in whom JVP evaluation is problematic. Mini Echo estimates of CVPs are comparable to physical examination by trained clinicians and require less instruction. The use of Mini Echo in medical training should be further evaluated and encouraged.  相似文献   

7.
8.
9.
10.
Venous ulcers.     
S. J. Fratesi  T. K. Scobie 《CMAJ》1982,126(6):631-635
  相似文献   

11.
Venous ulcers.     
  相似文献   

12.
13.
Certain types of stainless steel needles with metal hubs, and also a fistula set with projecting internal edges, were used at the venous end of the haemodialysis circuit and found to be associated with undesirable rises in extracorporeal pressure in 56 to 64% of dialyses. These increases in pressure are likely to be the result of platelet thrombus formation at the hub of the needle brought about by turbulent flow. The use of a plastic cannula and a stainless steel needle with a plastic hub, both of which have smooth internal surfaces, resulted in increases in pressure in only 4 to 12% of dialyses.  相似文献   

14.
《BMJ (Clinical research ed.)》1970,3(5721):507-508
  相似文献   

15.
16.
17.

Objective

Many studies have indicated that intra-abdominal pressure (IAP) is positively correlated with central venous pressure (CVP) in severe cases. However, although elevated IAP is common in patients with severe acute pancreatitis (SAP), its relationship with CVP remains unclear. Our study aimed to investigate the association of IAP with CVP in early-phase SAP patients.

Methods

In total, 116 SAP patients were included in this retrospective study. On the first day of hospitalization, blood samples were collected for biochemical examination and cytokine concentration monitoring. Additionally, a urinary catheter and right subclavian vein catheter were inserted for IAP and CVP measurement, respectively. Other routine clinical data were also recorded.

Results

Within 24 hours after hospitalization, CVP fluctuated and increased with increasing IAP up to 15.7 mmHg (P = 0.054) but decreased with increasing IAP when the IAP was > 15.7 mmHg (P < 0.001). After adjusting for abdominal perfusion pressure (APP) and mean arterial pressure (MAP), a similar distribution was observed. An inverted U-shaped trend between IAP and CVP was also present in the groups classified according to the patient’s sex, local complications, ascites, and serum amylase levels.

Conclusions

CVP and IAP have an inverted U-shaped relationship, with a peak at an IAP of 15.7 mmHg in the early phase of SAP. After this peak, CVP decreases as IAP increases. These results have crucial implications for clinical fluid resuscitation in SAP patients. In particular, because one CVP value might be correlated with different IAP values in patients with the same CVP, the volume of fluid needed might be different.  相似文献   

18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号