首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
3.
4.
An enzyme immunoassay technique for the detection of sulfamethoxypyridazine in honey, developed using rabbit polyclonal antibodies raised against N-sulfonyl-4-aminobutyric acid, which contains a structural group characteristic of sulfonamides, is proposed. Under the optimized conditions, the sulfamethoxypyridazine detection limit was 0.05 ng/ml, with the entire analysis procedure taking 2 h. In total, 24 honey samples were tested using the protocol based on tenfold dilutions of samples without their preliminary treatment.  相似文献   

5.
The development of a highly sensitive analytical method for oxytocin could be useful in the diagnosis and treatment of autistic spectrum disorder. We previously developed a colorimetric enzyme immunoassay (EIA) for plasma oxytocin measurement. In this study, we developed a method to measure oxytocin concentrations using a higher sensitivity bioluminescent EIA. Biotinylated oxytocin bridged with five lysine residues was used in a competitive format. The standard curve range for oxytocin was 1.0 to 1000 pg/assay. In addition, there was good correlation between the colorimetric and bioluminescent immunoassays in terms of measured oxytocin concentration (r = 0.9665, n = 48). The bioluminescent EIA for plasma oxytocin was more rapid and provided higher sensitivity than the colorimetric immunoassay, making it suitable for clinical application.  相似文献   

6.
A homogeneous enzyme immunoassay has been developed in which an antigen and glucose-6-phosphate dehydrogenase are coimmobilized on agarose beads. Binding of hexokinase-labeled antibody to the bead-bound antigen results in an accelerated conversion of glucose, ATP, and NAD+ to 6-phosphogluconolactone, ADP, and NADH. Critical parameters affecting assay response are discussed.  相似文献   

7.
An indirect competitive enzyme-linked immunosorbent assay (ELISA) of hexestrol (HES), an anabolic hormone forbidden for use in livestock farming, has been developed. Conditions of ELISA have been optimized by varying the concentrations of the coating conjugate (HES-ovalbumin), anti-HES antiserum, casein, and Tween 20. In the absence of Tween 20 in the reaction mixture, the detection limit (IC10) equaled 0.01 ng/ml, IC50 equaled 0.17 ng/ml, and the working range (IC20–IC80) equaled 0.03–0.86 ng/ml, while, in the presence of 0.05% Tween 20, these values equaled 0.05, 2.9, and 0.26–32.0 ng/ml, respectively. Standard deviation of the analysis results did not exceed 5.4%. If ELISA was performed in the absence of detergents, the recovery value upon HES determination in spiked beef samples ranged from 74 to 147%.  相似文献   

8.
Enzyme immunoassay for detection of Salmonellae in foods.   总被引:1,自引:6,他引:1       下载免费PDF全文
An enzyme immunoassay was developed to detect Salmonella in foods. Indirect test protocols were developed for use with microtitration plates or Gilford microcuvettes. Samples from enrichment cultures were mixed with H-specific immunoglobulin G and allowed to react; unbound antibody was removed by three 5-min centrifugation washes; goat anti-rabbit antibody conjugated to alkaline phosphatase was added and allowed to react; and unbound conjugate was removed by centrifugation washing as before. Salmonella-positive samples were indicated by the production of a chromogenic reaction product after the addition of alkaline phosphatase substrate. The color could be read visually or quantified by absorbance. Ninety-eight food samples were examined to compare the enzyme immunoassay with enrichment serology, immunofluorescence, and the Food and Drug Administration pure culture technique. The enzyme immunoassay was sensitive and specific, and it possessed advantages over methods currently in use. Furthermore, when the enzyme immunoassay was used to screen preenrichment media, the results indicated that it might be decidedly more sensitive than the conventional pure culture technique.  相似文献   

9.
Enzyme immunoassay for plasma estradiol using a monoclonal antibody   总被引:1,自引:0,他引:1  
A microtitre plate enzyme immunoassay (EIA) for plasma estradiol is described, involving competition between sample estradiol and an immobilized estradiol-bovine serum albumin complex for a monoclonal anti-estradiol antibody, followed by immobilized antibody quantitation using enzyme-labelled antiglobulins. The assay dose-response curve covered a range of 6-1500 fmol/well. The intra- and inter-assay coefficient of variation for the assay of three plasma pools ranged from 3.1 to 4.7% and from 4.7 to 10.6% respectively. The assay showed satisfactory correlation with a standard estradiol radioimmunoassay. Pre-coated microtitre plates were stable, dried, at 4 degrees C for up to 3 months and the anti-estradiol was stable to lyophilization and also was stable in solution at 4 degrees C for up to 1 month.  相似文献   

10.
An enzyme-linked immunosorbent assay (ELISA) system for hepatitis B e antigen (HBeAg) was developed employing beta-D-galactosidase conjugated with antibody to HBeAg (anti-HBe) and using m-maleimidobenzoyl-N-hydroxysuccinimide ester as the coupling reagent. The experimental conditions for quantitative assay of HBeAg were determined. The presence of rheumatoid factor in test sera did not affect the results. This assay system is more sensitive than the micro-Ouchterlony method and as sensitive as radioimmunoassay. The use of beta-D-galactosidase for ELISA in the field of virology is recommended.  相似文献   

11.
An enzyme immunoassay of serum testosterone using the testosterone-glucoamylase complex is described. Testosterone was estimated by the enzyme immunoassay after extraction with hexan: ether (4:1) for serum from men and additional thin layer chromatographic step for serum from women. The within and between assay errors, measured as the coefficient of variation were 11.1 percent (n=8) and 12.0 percent (n=12). The sensitivity of this assay was 0.25 ng. The mean testosterone concentration (+/- SD) in 19 normal men and 4 normal cycling women were 5.3 +/- 1.8 and 0.52 +/- 0.12 ng/ml, respectively. The level of testosterone found by the present assay compared favorably with those obtained by other methods.  相似文献   

12.
An immunoassay for thromboxane B2 was developed in which the hapten molecule was labeled with beta-galactosidase. The immunoprecipitate formed after competition between enzyme-labeled and unlabeled thromboxane B2 was subjected to a fluorometric assay of beta-galactosidase. Thromboxane B2 was detectable in the range of 0.1-30 pmol. Both enzyme immunoassay and radioimmunoassay showed essentially the same cross-reactivities with other prostaglandins and their metabolites when the same antibody was used. Known amounts of thromboxane B2 were added to human plasma, and the sample was applied to an octadecyl silica column. The extract was analyzed by enzyme immunoassay to examine the correlation between the added (x) and measured (y) thromboxane B2 (y = 1.09x + 11.07 pmol/ml, r = 0.99). A satisfactory correlation was observed between radioimmunoassay (x) and enzyme immunoassay (y) (y = 0.92x + 4.64 pmol/ml, r = 0.96). The validity of enzyme immunoassay was also confirmed by gas chromatography-mass spectrometry of a dimethylisopropylsilyl ether derivative of thromboxane B2 methyl ester. The method was applicable to the assay of thromboxane B2 produced from endogenous precursor during thrombin-induced aggregation of human platelets.  相似文献   

13.
Enzyme immunoassay of ampicillin in milk   总被引:2,自引:0,他引:2  
An indirect immunoassay for quantitative determination of ampicillin (range, 10-1000 ng/ml) in buffer or milk has been developed. Polyclonal antibodies were obtained against ampicillin conjugated with bovine serum albumin; the conjugate was synthesized by direct condensation using carbodiimide. The antibodies were specific for ampicillin and exhibited low cross-reactivity to other penicillins (azlocillin, 17%; penicillin G, 10%; piperacillin, 5%; and carbenicillin, 4%). Matrix effects were minimized by combining the use of a casein-supplemented buffer (content of casein, 1%) with sample dilution. The threshold of ampicillin detection in milk (diluted tenfold) was equal to 5.0 ng/ml (which corresponded to 50 ng/ml of the original sample).  相似文献   

14.
An enzyme immunoassay for serum 18-hydroxycorticosterone was established using alkaline phosphatase as a label. The antiserum for 18-hydroxycorticosterone was produced by immunization of rabbits with 18-hydroxycorticosterone 3-(O-carboxymethyl)oxime conjugated to bovine serum albumin. Sephadex LH-20 column chromatography was used to separate 18-hydroxycorticosterone from other steroids in serum samples. The minimal detectable amount of 18-hydroxycorticosterone was 50 pg/tube and the measurable range was from 5 to 1000 ng/dl when a 1.0 ml serum sample was used. Intra- and inter-assay coefficients of variance were 5.0% (n=6) and 5.8% (n=6), respectively. Four of 5 patients with aldosterone-producing adenoma had above-normal serum 18-hydroxycorticosterone levels.  相似文献   

15.
Enzyme immunoassay of the receptors for modified low density lipoprotein   总被引:1,自引:0,他引:1  
Mouse macrophages (line J 774) were incubated with monospecific goat anti-low density lipoprotein antibodies, which were conjugated to horseradish peroxidase (AB-HRP). Addition of low density lipoprotein (LDL) modified by treatment with malondialdehyde to cultures of these cells resulted in a dose-dependent increase in the amount of cell-associated enzyme activity. The concentration curve was hyperbolic with half-saturation of modified LDL at a concentration of about 3 micrograms/ml. This effect was completely blocked by polyinosinic acid and was not observed in experiments with human fibroblasts, which do not exhibit high affinity binding sites that recognize chemically modified LDL. Our data indicate that receptor-mediated endocytosis of AB-HRP in the presence of native or modified LDL may be used as very simple, efficient, and sensitive assay for investigation of the scavenger receptors for modified LDL.  相似文献   

16.
Cortisol 21-amine (21-amino-11β,17-dihydroxy-4-pregnene-3,20-dione) was prepared and an enzyme immunoassay for cortisol in serum was established using cortisol 21-amine conjugated with alkaline phosphatase. The minimal amount of cortisol detected was 1ng/tube and the measurable range was from 1 to 80 μg/d1, using 10 μ1 of serum sample. This enzyme immunoassay satisfied the standard criteria of dilution, accuracy and precision. The values correlated well with those obtained by radioimmunoassay. This enzyme Immunoassay is applicable to the routine determination of serum cortisol in any clinical laboratory. Cortisol 21-amine was found to be a useful derivative for preparing cortisol-enzyme conjugate in enzyme immunoassay.  相似文献   

17.
An indirect competitive enzyme-linked immunosorbent assay (ELISA) was developed using rabbit polyclonal antibodies against the eremomycin-glucose oxidase conjugated antigen. This technique allows the glycopeptide antibiotic eremomycin to be determined both in aqueous solutions (with a sensitivity as high as 0.1 ng/ml) and in blood plasma. The cross-reactivity of the antibodies with vancomycin was 0.4% of that for eremomycin, while teicoplanin was almost not recognized. Experiments with blood plasma samples diluted 1: 10 showed that the assay was linear over the concentration range 1–30 ng/ml and that the variation coefficient did not exceed 10%. The high sensitivity and selectivity of this test make it suitable for pharmacokinetic studies and drug monitoring analysis.  相似文献   

18.
The authors have previously reported a homogeneous time-resolved fluorescence proximity immunoassay for estradiol. The assay was based on luminescence resonance energy transfer between a long lifetime fluorescent europium(III) chelate-dyed nanoparticle donor and a short lifetime, near-infrared fluorescent acceptor. The energy transfer prolonged the lifetime of the sensitized acceptor emission, and the fluorescence of the acceptor was measured using a time-resolved detection. The developed immunoassay was employed to screen inhibitors for enzyme 17beta-hydroxysteroid dehydrogenase type 1. The enzyme overexpressed in MCF-7 cells catalyzed a reversible conversion of estroneto17beta-estradiol. The inhibition efficiency of the tested molecule was obtained by comparing the final concentration of converted estradiol after 60 min of conversion reaction in a sample and in a conversion control not containing an inhibitor. The Zbeta factor calculated using the E2 concentrations of the homogeneous assay was 0.64, demonstrating a relatively good performance of the assay. The results from the homogeneous assay were comparable with the results obtained using radioactively labeled estrone as a substrate and high-performance liquid chromatography (HPLC) separation of estrone and converted estradiol after the enzyme reaction. Thus, this homogeneous assay can simplify the primary screening of potential new drug molecules by replacing a tedious radiometric HPLC method.  相似文献   

19.
1. Enzyme modulator mediated immunoassay (EMMIA) is a separation-free (homogeneous) enzyme amplified immunoassay. 2. The assay is based on the ability of an analyte labeled enzyme modulator to modify the activity of an indicator enzyme and on ability of an anti-analyte antibody to abrogate the modifying action of the analyte-labeled enzyme modulator upon its binding to anti-analyte antibody. 3. The principle of EMMIA is elaborated in detail. The stages in the development of an EMMIA are described. 4. Criteria in selecting enzymes and modulators suitable for EMMIA are discussed. 5. Examples of EMMIA's using different kinds of modulators for different classes of analytes are presented.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号