共查询到20条相似文献,搜索用时 0 毫秒
1.
Quantitative analysis of free fatty acids was achieved using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) with a meso-tetrakis porphyrin matrix. Cesium acetate was employed as a cationizing agent. The MALDI signal was reproducible and dominated by cesiated cesium carboxylates [RCOOCs + Cs]+. The addition of two Cs ions resulted in a mass shift of 264.8 Da for each fatty acid and greatly reduced background peaks. A linear relationship between fatty acid concentration and corresponding fatty acid to internal standard peak intensity ratio was observed for three representative fatty acids analyzed across a concentration range from 4.40 to 150 microM, with correlation coefficients between 0.986 and 0.987. The application of this method was demonstrated with the analysis of free fatty acids in nonfasted and fasted rat plasmas. A total of eight free fatty acids (14:0, 16:0, 16:1, 17:0, 18:0, 18:1, 18:2, and 20:4) were detected. The relative peak height ratios of the fatty acids to the internal standard allow quantitative measurements of the free fatty acids. It was shown that the levels of free fatty acids were higher in fasted rats than in rats in a nonfasted state. This method is simple, sensitive, and fast. Thus, it provides an appealing tool for the analysis of free fatty acids or other low-molecular weight compounds during drug discovery and/or development. 相似文献
2.
3.
Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF) mass spectrometry was employed to analyze DNA methylation carried out by the Escherichia coli dam DNA methyltransferase using oligonucleotide substrates with molecular masses of 5000-10,000 Da per strand. The mass spectrometry assay offers several advantages: (i) it directly shows the methylation as the increase in the mass of the substrate DNA, (ii) it is nonradioactive, (iii) it is quantitative, and (iv) it can be automated for high-throughput applications. Since unmethylated and methylated DNA are detected, the ratio of methylation can be determined directly and accurately. Furthermore, the assay allows detection individually of the methylation of several substrates in competition, offering an ideal setup to analyze the specificity of DNA interacting with enzymes. We could not identify methylation at any noncanonical site, indicating that the dam MTase is a very specific enzyme. Finally, MALDI-TOF mass spectrometry permitted assessment of the number of methyl groups incorporated into each DNA strand, thereby, allowing study of mechanistic details such as the processivity of the methylation reaction. We provide evidence that the dam MTase modifies DNA in a processive reaction, confirming earlier findings. 相似文献
4.
David Alazard Mark Filipowsky Joanna Raeside Maureen Clarke Mehrdad Majlessi James Russell William Weisburg 《Analytical biochemistry》2002,301(1):57-64
A technique for sequencing oligonucleotides using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry is described. The series of coupling failure species are extracted from the dimethoxytrityl-on, full-length oligonucleotide in crude synthetic material using C18 stationary-phase cartridges. These concentrated failure species can be easily detected by MALDI-TOF, which determines the mass difference between spectral ions to identify a particular base. The solid-phase extraction step greatly enhances ion signals and mass resolution, and sequencing information is generally obtained from the 5' end up to the first three to four nucleotides at the 3' end. Complete sequence can be generated in conjunction with snake venom phosphodiesterase digestion of purified material. This method eliminates difficulties associated with other mass spectrometric sequencing techniques involving oligonucleotide length; structure; and sugar, base, and backbone modifications. Examples of sequencing a 17-mer composed primarily of 2'-O-methylribonucleotides and a single nonnucleosidic linker and a mixed sugar backbone 51-mer with 2'-O-methylribonucleotides and a homopolymer tail are reported in this study. 相似文献
5.
Müller M Schiller J Petkovic M Oehrl W Heinze R Wetzker R Arnold K Arnhold J 《Chemistry and physics of lipids》2001,110(2):151-164
Matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been recently established as a powerful tool for the analysis of biomolecules. Here, MALDI-TOF MS was used for the detection of (poly-)phosphoinositides (PPI). PPI possess higher molecular weights than other phospholipids and a high phosphorylation-dependent negative charge. Both features affect the MALDI detection limits expressed as the minimum of analyte on the sample plate resulting in a signal-to-noise-ratio of S/N=5. Using 2,5-dihydroxybenzoic acid (DHB) as matrix the detection limit for phosphatidylinositol (PI) is seven times higher than for phosphatidylcholine (PC) and further increases with increasing phosphorylation or in mixtures with other well-detectable phospholipids. For phosphatidylinositol-tris-phosphate (PIP3) in a mixture with PC, the limit is about 20 times higher than for PI. The consequences for the experimental conditions are discussed. It is advisable to pre-separate PPI from biological lipid mixtures prior to the application of MALDI-TOF MS. 相似文献
6.
Ogawa Y Traina J Zimmermann E Yu T Schneider DW Pungor E 《Analytical biochemistry》2007,368(2):214-221
The results of the characterization of a matrix-assisted laser desorption/ionization time-of-flight mass spectrometry-based method that was developed to establish the stoichiometry of CHX-A'-diethylenetriaminepentaacetic acid (DTPA) or benzyl-DTPA conjugated to a recombinant immunoglobulin G (IgG) are reported. This simple method does not require an accurate measurement of the sample protein concentration to accurately quantify the number of DTPA conjugated. It is also not necessary to thoroughly remove nonconjugated DTPA from the sample. The average number of moles of DTPA attached per mole of IgG was calculated from the difference in the observed masses of DTPA-IgG and nonconjugated IgG divided by the molecular weight of the DTPA derivative. As more DTPA is attached, the [M+H](+) peak of DTPA-IgG becomes broader and noisier. Also, the signal intensity in the mass spectrum decreases, apparently due to the increase in the heterogeneity in the number of DTPA attached to each molecule of IgG. The standard deviation of the measured mass and that of the stoichiometry of the DTPA attached per IgG increased as more DTPA was attached. The standard deviation, expressed as coefficient of variation for samples with 2 to 4 mol of DTPA attached per mole of IgG, was 8 to 9%. 相似文献
7.
8.
Amino acid analysis has been an integral part of analytical biochemistry for more than 50 years. However, its experimental design, which includes derivatization of amino acids followed by some kind of chromatographic separation, has not changed over the years. We have developed a matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF)-based method for the quantitative analysis of amino acids. This method does not require any amino acid modification, derivatization, or chromatographic separation. The data acquisition time is decreased to several seconds for a single sample. No significant ion suppression effects were observed with the developed sample deposition technique, and the method was found to be reproducible. Linear responses between the amino acid concentration and the peak intensities ratio of corresponding amino acid to internal standard were observed for all amino acids analyzed in the range of concentrations from 20 to 300 microM, and correlation coefficients were between 0.983 (for arginine) and 0.999 (for phenylalanine). Limits of quantitation were between 0.03 microM (for arginine) and 3.7 microM (for histidine and homocysteine). This method was applicable to the mixtures of free amino acids as well as to HCl hydrolysates of proteins. Furthermore, we have shown that this method can be applied to other biologically important low-molecular weight compounds such as glucose. 相似文献
9.
Buskirk AD Hettick JM Chipinda I Law BF Siegel PD Slaven JE Green BJ Beezhold DH 《Analytical biochemistry》2011,(1):122-128
The analysis of urinary acylglycines is an important biochemical tool for the diagnosis of many organic acidemias and mitochondrial fatty acid β-oxidation defects. A new rapid analytical method has been developed for quantification of acylglycines in urine by liquid chromatography coupled with tandem mass spectrometry (LC–MS/MS). The method requires a simple sample preparation avoiding derivatization. It has high sensitivity, specificity, and throughput capability, and it requires minimal instrument maintenance. The use of chromatographic separation allows us to identify and quantify isomeric compounds that cannot be solved by appropriate multiple reaction monitoring (MRM) transitions. Urinary concentrations of the different acylglycines were determined using deuterated internal standards. The reference interval for the various metabolites was established using 120 healthy controls. The diagnostic usefulness of the method was demonstrated in three patients with propionic acidemia (PA), one patient with isovaleric acidemia (IVA), two patients with beta ketothiolase deficiency (BKTD), one patient with short branched chain amino acid deficiency (SBCAD), four patients with medium chain acyl-coenzyme A dehydrogenase deficiency (MCADD), one patient with isobutyryl-coenzyme A dehydrogenase deficiency (IBDHD), and one patient with multiple acyl-coenzyme A dehydrogenase deficiency (MADD). 相似文献
10.
Reversible phosphorylation is one of the most important posttranslational modifications of cellular proteins. Mass spectrometry is a widely used technique in the characterization of phosphorylated proteins and peptides. Similar to nonmodified peptides, sequence information for phosphopeptides digested from proteins can be obtained by tandem mass analysis using either electrospray ionization or matrix assisted laser desorption/ionization (MALDI) mass spectrometry. However, the facile loss of neutral phosphoric acid (H3PO4) or HPO3 from precursor ions and fragment ions hampers the precise determination of phosphorylation site, particularly if more than one potential phosphorylation site or concensus sequence is present in a given tryptic peptide. Here, we investigated the fragmentation of phosphorylated peptides under laser-induced dissociation (LID) using a MALDI-time-of-flight mass spectrometer with a curved-field reflectron. Our data demonstrated that intact fragments bearing phosphorylated residues were produced from all tested peptides that contain at least one and up to four phosphorylation sites at serine, threonine, or tyrosine residues. In addition, the LID of phosphopeptides derivatized by N-terminal sulfonation yields simplified MS/MS spectra, suggesting the combination of these two types of spectra could provide an effective approach to the characterization of proteins modified by phosphorylation. 相似文献
11.
Matrix-assisted laser desorption/ionization quadrupole ion trap time-of-flight mass spectrometry (MALDI-QIT-TOF MS) was used
to analyze three pyridylamino (PA)-fucosyloligosaccharides isolated from human milk: lacto-N-fucopentaose (LNFP) I [Fucα1-2Galβ1-3GlcNAcβ1-3Galβ1-4Glc-PA],
LNFP II [Galβ1-3(Fucα1-4)GlcNAcβ1-3Galβ1-4Glc-PA], and LNFP III [Galβ1-4(Fucα1-3)GlcNAcβ1-3Galβ1-4Glc-PA]. These oligosaccharides
are linkage isomers. MALDI-QIT-TOF MS provides MSn spectra, which we used to characterize these PA-oligosaccharides. MS/MS/MS analysis of the non-reducing end tri-saccharide
ions generated by MS/MS was able to distinguish these oligosaccharide isomers. The MALDI-QIT-TOF MS is a very convenient and
rapid method, therefore, it would be useful for high throughput structural analyses of various types of pyridylaminated oligosaccharide
isomers. 相似文献
12.
13.
Kurien BT Patel NC Porter AC Kurono S Matsumoto H Wang H Scofield RH 《Analytical biochemistry》2004,331(2):224-229
Proline-containing peptides of the X-proline type are cleaved by the dipeptidase prolidase. The classical method of prolidase assay relied on the colorimetric estimation of the liberated proline with ninhydrin using acidic media and heat. This method, however, gave inconsistent results due to the nonspecificity of the ninhydrin color reaction. We report here a method for the detection of the liberated proline using matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Human sera were incubated with a mixture containing the dipeptide glycyl-proline in Tris-HCl supplemented with manganese at 37 degrees C for 24h. The samples were precipitated with trifluoroacetic acid and centrifuged. An aliquot of the supernatant was mixed with an equal volume of ferulic acid solution. An aliquot from this mixture was spotted on a stainless steel mass spectrometry grid and analyzed using MALDI-TOF mass spectrometry. The activity of the enzyme was determined by the complete disappearance of the glycyl-proline peak with the concomitant appearance of the proline peak and can be expressed in terms of the ratio of the area beneath the proline to the area beneath the glycyl-proline peak. Subjects homozygous for prolidase deficiency had a ratio ranging from 0.006 to 0.04 while obligatory heterozygotes had a ratio ranging from around 1.1 to 2.4. Normal subjects had ratios ranging from 9 to 239. Using this method we have unambiguously identified subjects with homozygous or heterozygous prolidase deficiency. In addition to the advantage of rapid sample preparation time, this method is highly specific, reproducible, and sensitive. 相似文献
14.
AIM: Application of MALDI-TOF MS for characterization of strains of Salmonella enterica subsp. enterica. METHODS AND RESULTS: Whole cells were analysed by MALDI-TOF MS. Spectra with a maximum of 500 mass peaks between (m/z) 0 and 25000 were examined for consensus peaks manually and by a computer software algorithm. Consensus peaks were observed by both methods for spectra of Salmonella enterica serovars Derby, Hadar, Virchow, Anatum, Typhimurium and Enteritidis. CONCLUSIONS: Differences in numbers of consensus peaks in spectra obtained by manual and computer comparison indicated that development of the software involving statistical analysis of peak accuracy is necessary. SIGNIFICANCE AND IMPACT OF THE STUDY: Development of an analysis system for peak profiles in whole cell MALDI-TOF MS spectra to enable intra and interlaboratory comparison. 相似文献
15.
Karine Guitot Silvia Scarabelli Thierry Drujon Gérard Bolbach Mehdi Amoura Fabienne Burlina Albert Jeltsch Sandrine Sagan Dominique Guianvarc’h 《Analytical biochemistry》2014
Histone lysine methyltransferases (HKMTs) are enzymes that play an essential role in epigenetic regulation. Thus, identification of inhibitors specifically targeting these enzymes represents a challenge for the development of new antitumor therapeutics. Several methods for measuring HKMT activity are already available. Most of them use indirect measurement of the enzymatic reaction through radioactive labeling or antibody-recognized products or coupled enzymatic assays. Mass spectrometry (MS) represents an interesting alternative approach because it allows direct detection and quantification of enzymatic reactions and can be used to determine kinetics and to screen small molecules as potential inhibitors. Application of mass spectrometry to the study of HKMTs has not been fully explored yet. We describe here the development of a simple reliable label-free MALDI-TOF MS-based assay for the detection and quantification of peptide methylation, using SET7/9 as a model enzyme. Importantly, the use of expensive internal standard often required in mass spectrometry quantitative analysis is not necessary in this assay. This MS assay allowed us to determine enzyme kinetic parameters as well as IC50 for a known inhibitor of this enzyme. Furthermore, a comparative study with an antibody-based immunosorbent assay showed that the MS assay is more reliable and suitable for the screening of inhibitors. 相似文献
16.
The aim of this study was to discriminate 30 Vibrio strains isolated from two wastewater treatment plants from Agadir, Morocco by two molecular typing methods, pulsed-field gel electrophoresis (PFGE) and matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS). Out of the 30 strains of Vibrio examined in this study, 5 isolates could not be typed by PFGE and consistently appeared as a smear on the gel. In general, high genetic biodiversity among the Vibrio strains was found regardless to the isolation source. The results of MALDI TOF analysis show a high congruence of strain grouping demonstrating the accuracy and reliability of MALDI-TOF MS. 相似文献
17.
Oligonucleotides containing modified bases are commonly used for biochemical and biophysical studies to assess the impact of specific types of chemical damage on DNA structure and function. In contrast to the synthesis of oligonucleotides with normal DNA bases, oligonucleotide synthesis with modified bases often requires modified synthetic or deprotection conditions. Furthermore, several modified bases of biological interest are prone to further damage during synthesis and oligonucleotide isolation. In this article, we describe the application of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) to the characterization of a series of modified synthetic oligonucleotides. The potential for and limits in obtaining high mass accuracy for confirming oligonucleotide composition are discussed. Examination of the isotope cluster is also proposed as a method for confirming oligonucleotide elemental composition. MALDI-TOF-MS analysis of the unpurified reaction mixture can be used to confirm synthetic sequence and to reveal potential problems during synthesis. Analysis during and after purification can yield important information on depurination and base oxidation. It can also reveal unexpected problems that can occur with nonstandard synthesis, deprotection, or purification strategies. Proper characterization of modified oligonucleotides is essential for the correct interpretation of experiments performed with these substrates, and MALDI-TOF-MS analysis provides a simple yet extensive method of characterization that can be used at multiple stages of oligonucleotide production and use. 相似文献
18.
A capillary electrophoretic method (CE) for characterizing PEGylated human parathyroid hormone 1-34 (PTH) with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is described. CE was used to optimize the PEGylation of PTH through control of the reaction pH and the molar ratio of reactants with the advantages of minimal sample consumption and high separation capacity. The mono-PEGylated PTH (mono-PEG-PTH) was isolated and then digested with endoproteinase Lys-C. Resistance to Lys-C digestion on the PEGylation sites in the mono-PEG-PTH resulted in patterns of CE electropherograms different from that of the native PTH, and the PEGylation sites were assigned accordingly. The extent of positional isomers present in the mono-PEG-PTH was also determined by quantifying PEGylated fragments in the same CE electropherogram. In conclusion, the CE analysis of the Lys-C-digested sample allowed for simultaneous analysis of the PEGylation site and the extent of positional isomers in the mono-PEG-PTH. The results were confirmed by MALDI-TOF MS. This method will be applicable for characterizing PEGylation of other therapeutic peptides. 相似文献
19.
Florence Gaucher-Wieczorek Vincent GuérineauDavid Touboul Sophie Thétiot-LaurentFranck Pelissier Marie-Ange Badet-DenisotBernard Badet Philippe Durand 《Analytical biochemistry》2014
Glucosamine-6-phosphate synthase (GlmS, EC 2.6.1.16) catalyzes the first and rate-limiting step in the hexosamine biosynthetic pathway, leading to the synthesis of uridine-5′-diphospho-N-acetyl-d-glucosamine, the major building block for the edification of peptidoglycan in bacteria, chitin in fungi, and glycoproteins in mammals. This bisubstrate enzyme converts d-fructose-6-phosphate (Fru-6P) and l-glutamine (Gln) into d-glucosamine-6-phosphate (GlcN-6P) and l-glutamate (Glu), respectively. We previously demonstrated that matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) allows determination of the kinetic parameters of the synthase activity. We propose here to refine the experimental protocol to quantify Glu and GlcN-6P, allowing determination of both hemisynthase and synthase parameters from a single assay kinetic experiment, while avoiding interferences encountered in other assays. It is the first time that MALDI-MS is used to survey the activity of a bisubstrate enzyme. 相似文献
20.
We report a method to detect the presence of dimethylarginines on proteins. Peptides with dimethylarginines were hydrolyzed in acid. The hydrolysates were subjected to matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometric analysis using a mixture of alpha-cyano-4-hydroxycinnamic acid and nitrocellulose as matrix. Both asymmetric omega-N(G),N(G)-dimethylarginine and symmetric omega-N(G),N(G')-dimethylarginine give a clear signal at m/z 203. Recombinant Sbp1p modified by Hmt1p in vivo were isolated by affinity chromatography followed by electrophoresis on a polyacrylamide gel and subjected to acid hydrolysis. MALDI-TOF analysis of the acid hydrolysates confirmed the presence of dimethylarginines. The detection limit of the method is estimated at approximately 1pmol of protein. 相似文献