首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and sensitive flow-injection electrogenerated chemiluminescence (ECL) method for the determination of fluoroquinolones was developed. The method is based on the sensitizing effect of fluoroquinolones on the weak ECL signal of electrochemical oxidation of luminol on the surface of the platinum flake electrode in the medium of 0.1 mol/L Na2CO3-NaHCO3. At the optimum experimental conditions, the relative ECL intensity increased linearly with increasing fluoroquinolones concentration, in the ranges 1.0 x 10(-8)-2.0 x 10(-4) g/mL for norfloxacin, 5.0 x 10(-9)-6.0 x 10(-6) g/mL for oxfloxacin, 2.0 x 10(-8)-1.4 x 10(-5) g/mL for ciprofloxacin, 1.0 x 10(-8)-1.4 x 10(-5) g/mL for pefloxacin, and 1.0 x 10(-9)-1.0 x 10(-5) g/mL for enoxacin, with detection limits of 4.0 x 10(-9) g/mL, 2.0 x 10(-9) g/mL, 1.0 x 10(-8) g/mL, 8.0 x 10(-9) g/mL, and 8.0 x 10(-10) g/mL, respectively. The relative standard deviations were all less than 2.5% for the determination of 2.0 x 10(-6) g/mL fluoroquinolones (n = 11). The method was used to determine these medicines in pharmaceutical samples with satisfactory results.  相似文献   

2.
A simple electrogenerated chemiluminescence (ECL) analysis method for the determination of norfloxacin (NFLX) is reported. It is based on ECL produced by Na(2)SO(3), which is sensitized by the Tb-NFLX complex. The relative ECL intensity of the Tb(3+)-NFLX-Na(2)SO(3) system is proportional to the amount of NFLX. The optimized experimental conditions were investigated. The linear range and detection limit for NFLX were 1.0 x 10(-10)-8.0 x 10(-7) mol/L and 2.8 x 10(-11) mol/L, respectively. This method was successfully applied to the determination of NFLX in a capsule. NFLX in urine can be directly detected without pretreatment or separation.  相似文献   

3.
An ECL approach was developed for the determination of codeine or morphine based on tris(2,2'-bipyridine)ruthenium(II) (Ru(bpy)(3)(2+)) immobilized in organically modified silicates (ORMOSILs). Tetramethoxysilane (TMOS) and dimethyldimethoxysilane (DiMe-DiMOS) were selected as co-precursors for ORMOSILs, which were then immobilized on a surface of glassy carbon electrode (GCE) by a dip-coating process. Ru(bpy)(3)(2+) was immobilized in the ORMOSIL film via ion-association with poly(p-styrenesulphonate). The ORMOSIL-modified GCE presented good electrochemical and photochemical activities. In a flow system, the eluted codeine or morphine was oxidized on the modified GCE and reacted with immobilized Ru(bpy)(3)(2+) at a potential of +1.20 V (vs. Ag/AgCl). The modified electrode was used for the ECL determination of codeine or morphine and showed high sensitivity. The calibration curves were linear in the range 2 x 10(-8)-5 x 10(-5) mol/L for codeine and 1 x 10(-7)-3 x 10(-4) mol/L for morphine. The detection limit was 5 x 10(-9) mol/L for codeine and 3 x 10(-8) mol/L for morphine, at signal:noise ratio (S:N)=3. Both codeine and morphine showed reproducibility with RSD values <2.5% at 1.0 x 10(-6) mol/L. Furthermore, the modified electrode immobilized Ru(bpy)(3)(2+) was applied to the ECL determination of codeine or morphine in incitant samples.  相似文献   

4.
We discovered that 4-(2-pyridylazo) resorcinol (PAR) has a strong catalytic effect on luminol-potassium ferricyanide chemiluminescence (CL). Results indicated that the chemiluminescence intensities at maximum light emission were linearly corrected with the concentration of PAR over the range 1.0 x 10(-5)-1.0 x 10(-7) mol/L. A detection limit of 5.7 x 10(-8) mol/L for PAR was achieved. It was found that some metal ions strongly affected this catalytic reaction. Based on this finding, the luminol-potassium ferricyanide-PAR reaction was developed for the determination of metal ions. The detection limits (S/N = 3) for Ni2+, Cr3+, Zn2+, Co2+ and Mn2+ were determined to be 1.0 x 10(-9) mol/L, 5.0 x 10(-9) mol/L, 5.0 x 10(-8) mol/L, 1.0 x 10(-9) mol/L and 1.0 x 10(-8) mol/L, respectively. In addition, the relative standard deviation values for these metal ion assays were in the range 0.82-2.72% (n = 6).  相似文献   

5.
Ming Li  Sang Hak Lee 《Luminescence》2007,22(6):588-593
A capillary electrophoresis with electrogenerated chemiluminescence (CE-ECL) method for the determination of trimethylamine (TMA) in fish was studied. In the presence of TMA, ECL from the reaction of analyte and in situ generated tris(2,2'-bipyridyl)ruthenium(III) [Ru(bpy)(3) (3+)] at electrode surface could be produced. The ECL detection was performed using a Pt working electrode biased at 1.23 V (vs. Ag/AgCl) potential in a 10 mmol/L sodium borate buffer solution, pH 9.2, containing 3 mmol/L Ru(bpy)(3) (2+). A linear calibration curve (correlation coefficient = 0.9996) was obtained in the range 8 x 10(-5)-4 x 10(-8) mol/L for TMA concentration. Recoveries obtained were in the range 98.78-101.46%. The method was successfully applied for the assay of TMA in fish, in combination with solid phase extraction (SPE) disks for sample clean-up and enrichment.  相似文献   

6.
A new flow injection chemiluminescence (CL) method has been developed for the determination of bisphenol A (BPA), based on the inhibitory effect of BPA on the chemiluminescence reaction between luminol and potassium hexacyanoferrate. Under optimum conditions, the decrease in CL emission intensity was linear with BPA concentration in the range 8.0 x 10(-7)-1.2 x 10(-5) mol/L, and the detection limit was 3.1 x 10(-7) mol/L. The relative standard deviation (RSD) of 11 replicate measurements was 2.6% for 2.0 x 10(-6) mol/L BPA (n = 11). The sampling frequency was calculated to be ca. 120/h. This method has been successfully used to determine the content of BPA in aqueous solution of polycarbonate materials. A brief discussion on the possible chemiluminescence reaction mechanism is presented.  相似文献   

7.
本文研究了顺铂对小鼠艾氏腹水肝癌细胞膜蛋白内源性荧光的淬灭作用和测定了其在膜上的结合量。结果表明顺铂能与癌细胞膜结合。按存在两类结合部位,得到表观结合常数和结合部位数为: K_1=1.35×10~5L/mol n_1=6.80×10~(-4)mol/g(protein) K_2=2.50×10~3L/mol n_2=1.92×10~(-3)mol/g(protein)  相似文献   

8.
An electrochemiluminescence (ECL) based on energy transfer from electro-generated triplet sulfur dioxide to pipemidic acid (PPA) was studied. A weak ECL from triplet sulfur dioxide (3)SO2 * was observed when sulfite was electrochemically oxidized in sulfuric acid solution on a Pt electrode. When PPA was present, the weak ECL was enhanced. The enhanced ECL was attributed to energy transfer from (3)SO2 * to PPA. Based on the enhanced ECL, a flow-injection (FIA) ECL method for the determination of PPA was proposed. The proposed method allowed the measurement of PPA over the range of 1.0x10(-7) to 2.0x10(-5)moll(-1). The detection limit was 3.9x10(-8)moll(-1), and the relative standard deviation for 1.0x10(-6)moll(-1) PPA (n=9) was 1.3%. This method was evaluated by the analysis of PPA in pharmaceutical preparations and urine samples.  相似文献   

9.
Cathodic electrochemiluminescence (ECL) behaviours of the acetonitrile, acetonitrile-1,10-phenanthroline (phen) and acetonitrile-ternary Eu(III) complex systems at a gold electrode were studied. One very weak cathodic ECL-2 at -3.5 V was observed in 0.1 mol/L tetrabutylammonium tetrafluoroborate (TBABF(4)) acetonitrile solution. When 10 mmol/L tetrabutylammonium peroxydisulphate [(TBA)(2)S(2)O(8)] was added to 0.1 mol/L TBABF(4) acetonitrile solution, another cathodic ECL-1 at -2.7 V appeared and the potential for ECL-2 was shifted from -3.5 to -3.1 V. Furthermore, ECL-2 intensity was enhanced about 20-fold. When 1 x 10(-4) mol/L phen was added to 0.1 mol/L TBABF(4) + 10 mmol/L (TBA)(2)S(2)O(8) acetonitrile solution, the ECL intensities of ECL-1 and ECL-2 were enhanced about 20-fold compared with those of 0.1 mol/L TBABF(4) + 10 mmol/L (TBA)(2)S(2)O(8) acetonitrile solution. The maximum emission peaks of ECL-1 and ECL-2 in the three systems mentioned above appeared at about 530 nm. The products obtained by electrolysing 0.1 mol/L TBABF(4) acetonitrile solution at -3.5 V for 20 min were analysed by Fourier Transform Infrared (FTIR) spectra and gas chromatography-mass spectrometry (GC-MS) and the emitter of ECL-1 and ECL-2 was identified as excited state polyacetonitrile. When ternary Eu(III) complexes were presented in 0.1 mol/L TBABF(4) + 10 mmol/L (TBA)(2)S(2)O(8) acetonitrile solution, another maximum emission peak with a narrow band centred at about 610 nm appeared in ECL-1 in addition to the maximum emission peaks at about 530 nm for ECL-1 and ECL-2. The emitter of ECL emission at 610 nm was identified as the excited states Eu(III)*. The mechanisms for cathodic ECL behaviours of the acetonitrile, acetonitrile-phen and acetonitrile-ternary Eu(III) complex systems at a gold electrode have been proposed. The extremely sharp emission bands for ternary Eu(III) complexes may have analytical potential.  相似文献   

10.
In this paper, multi-wall carbon nanotubes (MWNTs)/Pt microparticles nanocomposite was prepared by electrodepositing Pt microparticles onto the MWNTs matrix. The surface of glassy carbon electrode was modified with this kind of nanocomposite for measurement of thiols, such as L-cysteine (L-Cys) and glutathione (GSH). Compared with the MWNTs or Pt microparticles modified electrode, the nanocomposite modified electrode exhibited high sensitivity and good stability for detection of thiols. According to the results of experiments, the peak currents of L-Cys and GSH are linear with their concentrations and the detection limits (S/N=3) are 2.9 x 10(-8) mol/L and 4.5 x 10(-8) mol/L, respectively. Coupled with microdialysis, the method has been successfully applied to the determination of these two thiols in rat striatal microdialysates.  相似文献   

11.
A novel CL method for the determination of tannic acid (TA) was established based on TA inhibition of the chemiluminescence (CL) emission of the luminol-hydrogen peroxide CL system catalysed by tetrasulphonated manganese phthalocyanine (MnTSPc) under alkaline conditions. The peak height is proportional to the natural logarithm of concentration of TA in the range 1.0 x 10(-7)-3.0 x 10(-10) mol/L with a detection limit of 5.6 x 10(-11) mol/L and the relative standard deviation was 2.5% for the determination of 1.0 x 10(-8) mol/L TA (n = 11). The proposed method has been successfully applied to the determination of TA in Chinese gall and industrial wastewater.  相似文献   

12.
The reaction of soluble manganese (IV) with sulphite in acidic condition was found to elicit weak chemiluminescence (CL). The CL signal was remarkably enhanced in the presence of three fluoroquinolones, viz. norfloxacin, ofloxacin and ciprofloxacin. Based on these observations, a new flow-injection CL method was developed for the determination of these fluoroquinolones. The method allows determination in the range 5.0 x 10(-8)-1.0 x 10(-6) mol/L for norfloxacin, 1.0 x 10(-7)-8.0 x 10(-6) mol/L for ofloxacin and 1.0 x 10(-7)-3.0 x 10(-5) mol/L for ciprofloxacin, with detection limits of 3 x 10(-8) mol/L, 5 x 10(-8) mol/L and 3 x 10(-8) mol/L, respectively. The method was applied to the determination of fluoroquinolones in pharmaceutical preparations.  相似文献   

13.
非洲爪蟾卵母细胞GABAB和GABAc受体介导的电流反应   总被引:4,自引:0,他引:4  
Yang Q  Li ZW  Wei JB 《生理学报》2001,53(4):311-315
实验应用双电极电压箝技术,在具有滤泡膜的非洲爪蟾(Xenopuslaevis)卵母细胞上记录到γ-氨基丁酸(γ-aminobutyricacid,GABA)-激活电流。此GABA-激活电流的特点及有关GABA受体类型的研究和分析如下(1)在35.5%(55/155)的受检细胞外加GABA可引起一慢的浓度依赖性的外向电流。(2)GABAA受体的选择性拮抗剂bicuculline(10  相似文献   

14.
A novel method for simultaneous determination of atenolol, metoprolol and esmolol was proposed by capillary electrophoresis (CE) separation and electrochemiluminescence (ECL) detection. Poly-β-cyclodextrin (Poly-β-CD) was used as an additive in the running buffer to improve the separation of three analytes. The conditions for CE separation, ECL detection and effect of Poly-β-CD were investigated in detail. The three β-blockers with very similar structures were well separated and detected under the optimum conditions. The linear ranges of the standard solution for atenolol and esmolol were 2.5-125 μmol/L with a detection limit (S/N=3) of 0.5 μmol/L, and for metoprolol was 0.5-25 μmol/L with a detection limit of 0.1 μmol/L. For three β-blockers from spiked aqueous and urine samples, the accuracy and precision including intraday and interday experiments were performed by calculating the recovery, the relative standard deviations of the ECL intensity and the migration time, respectively. The developed method was applied to the determination of metoprolol content in commercial pharmaceutical, and the analytical results are in good agreement with the nominal value with recoveries in the range of 98.7-105%. The proposed method was also applied to the monitoring of pharmacokinetics for metoprolol in human body.  相似文献   

15.
A new flow injection (FI) method for the precise and rapid spectrophotometric determination of the antibiotic fosfomycin (FMC) in urine and pharmaceutical samples is described. The method is based on the on-line quantitative thermal-induced digestion of the analyte prior to injection into the FI system. Ammonium persulfate was used as the oxidation reagent. The resulting orthophosphate ions were determined spectrophotometrically (lambda(max) = 690 nm) using the molybdenum blue approach. Chemical and FI variables that affected on-line oxidation were studied and optimized. The proposed method is very precise (s(r) = 1.2% at 1.0 x 10(-4) mol L(-1) FMC, n = 12), offers a high sampling rate of 60 h(-1), and allows for the determination of the analyte in the range 3.0 x 10(-6) to 3.0 x 10(-4) mol L(-1) with a satisfactory 3sigma detection limit of 1.0 x 10(-6) mol L(-1). Application of the proposed method to urine and pharmaceutical samples yielded accurate results with percentage recoveries in the range 96.4-102.5%.  相似文献   

16.
A method of indirectly measuring pyruvic acid (PA) by capillary electrophoresis with amperometric detection is proposed for the first time. It is based on the oximation reaction between PA and hydroxylamine (NH(2)OH), and the quantification of PA was performed by direct and sensitive amperometric detection of excessive NH(2)OH after the oximation reaction. This method displayed a good sensitivity, and the detection limits of NH(2)OH and PA are 1.76 x 10(-7) and 3.88 x 10(-7)mol/L, respectively at S/N=3. The linear relationship between the peak current and PA concentration is exhibited over the range from 4 x 10(-6) to 1 x 10(-4)mol/L. This method has been applied to determine PA in rat plasma with satisfactory results.  相似文献   

17.
Electrogenerated chemiluminescence (ECL) of thiol‐capped CdTe quantum dots (QDs) in aqueous solution was greatly enhanced by PDDA‐protected graphene (P‐GR) film that were used for the sensitive detection of H2O2. When the potential was cycled between 0 and ?2.3 V, two ECL peaks were observed at ?1.1 (ECL‐1) and ?1.4 V (ECL‐2) in pH 11.0, 0.1 M phosphate buffer solution (PBS), respectively. The electron‐transfer reaction between individual electrochemically‐reduced CdTe nanocrystal species and oxidant coreactants (H2O2 or reduced dissolved oxygen) led to the production of ECL‐1. While mass nanocrystals packed densely in the film were reduced electrochemically, assembly of reduced nanocrystal species reacted with coreactants to produce an ECL‐2 signal. ECL‐1 showed higher sensitivity for the detection of H2O2 concentrations than that of ECL‐2. Further, P‐GR film not only enhanced ECL intensity of CdTe QDs but also decreased its onset potential. Thus, a novel CdTe QDs ECL sensor was developed for sensing H2O2. Light intensity was linearly proportional to the concentration of H2O2 between 1.0 × 10?5 and 2.0 x 10‐7 mol L?1 with a detection limit of 9.8 x 10?8 mol L?1. The P‐GR thin‐film modified glassy carbon electrode (GCE) displayed acceptable reproducibility and long‐term stability. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

18.
Electrogenerated chemiluminescence (ECL) of a ruthenium complex polymer modified carbon paste electrode and its analytical applications were investigated. The ruthenium complex polymer was prepared using bis(2,2‐bipyridine) (4,4‐dicarboxy‐2,2‐bipyridine) ruthenium(II). The ECL behaviours of ruthenium complex polymer modified carbon paste electrode were investigated in the absence and presence of tripropylamine (TPA). The modified carbon paste electrode exhibited long‐term stability and fine reproducibility. The ECL intensity of the modified carbon paste electrode was linear with the concentration of TPA in the range 2.0 × 10–6–3.8 × 10–3 mol/L, with a detection limit (S:N = 3) of 6 × 10–7 mol/L. It was also found that raceanisodamine could enhance the ECL intensity of the modified electrode. The ECL intensity of the modified carbon paste electrode was linear with the concentration of raceanisodamine in the range 1.1 × 10–5–6.0 × 10–4 mol/L, with a detection limit (S:N = 3) of 6 × 10–6 mol/L. This work demonstrates that the entrapment of ruthenium complex in a highly cross‐linked polymer is a promising approach to construct an ECL modified electrode with long‐term stability and fine reproducibility. The modified electrode designed has a potential application in the ECL detector. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

19.
A novel strategy for the enhancement of electrochemiluminescence (ECL) was developed by combining CdSe quantum dots (QDs) with graphene oxide-chitosan (GO-CHIT). The ECL sensor fabricated with CdSe QDs/GO-CHIT composite exhibited high ECL intensity, good biocompatibility and long-term stability, and was used to detect of cytochrome C (Cyt C). The results show that the ECL sensor has high sensitivity for Cyt C with the linear range from 4.0 to 324 μM and the detection limit of 1.5 μM. Furthermore, the ECL sensor can selectively sense Cyt C from glucose and bovine serum albumin (BSA).  相似文献   

20.
李超英  李之望 《生理学报》1990,42(5):437-445
在离体灌流的蟾蜍背根神经节(DRG)标本上,用微电极进行胞内记录。在73个神经元中,依神经纤维的传导速度将神经元分为 A 型及 C 型,其中 A 型细胞67个,C 型6个,静息膜电位为-67.5±1.3mV((?)±SE)。当加4×10~(-4)—6×10~(-4)mol/L 乙酰胆碱(ACh),可观察到如下四种膜电位变化:1.超极化:幅值9.1±3.0mV((?)±SE,n=23);(2)去极化:幅值12.9±2.2mV((?)+SE,n=20);(3)双相反应(n=24):先超极化,后去极化,超极化幅值8.0±2.4mV((?)+SE),去极化幅值10.9±3.1mV((?)±SE);(4)无反应(n=6)。用阿托品(1.3×10~(-5)mol/L,n=23),或同时应用筒箭毒与六甲双铵(浓度均为1.4×10~(-5)mol/L,n=8)灌流,能分别阻断 ACh 引起的膜的超极化或去极化。ACh 引起超极化反应时膜电导平均增加13.8%,翻转电位值大约-96mV。四乙铵(TEA,20mmol/L)能使 ACh 的去极化幅值增加48.2±3.2%((?)±SE,n=6),超极化幅值减小79.4±4.3%((?)±SE,n=8)。MnCl_2(4mmol/L)使 ACh 的去极化及超极化幅值分别减小54.2±7.2%((?)±SE,n=5)及69.2±6.4%((?)±SE,n=14)。以上结果提示:ACh 引起的 DRG 神经细胞膜去极化反应由 N 型乙酰胆碱受体介导,而超极化反应由 Μ 型乙酰胆碱受体介导,前者可能包含了多种离子电导的改变,后者则可能与钾电导增加有关。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号