首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
饮用水微生物的安全快速检测   总被引:2,自引:0,他引:2  
【目的】为了更好地分析饮用水中的微生物含量。【方法】利用流式细胞术(Flowcytometry,FCM)、ATP测定方法检测瓶装无气饮用水中的微生物数量、可同化有机碳(Assimilable organic carbon,AOC)含量以及微生物活性,并将检测结果与传统的饮用水微生物检测技术相对照。【结果】FCM方法可快速区分水样中的活性细菌和非活性细菌,AOC含量反映了水样中微生物再生能力;而ATP检测方法也能比异养细菌平板计数法(Heterotrophic plate count,HPC)更好地反映瓶装无气饮用水中的实际微生物含量。【结论】FCM、ATP测定方法要明显优于依赖于培养的传统方法。  相似文献   

2.
A mathematical model for a three phase fluidized bed bioreactor (TFBBR) was proposed to describe oxygen utilization rate, biomass concentration and the removal efficiency of Chemical Oxygen Demand (COD) in wastewater treatment. The model consisted of the biofilm model to describe the oxygen uptake rate and the hydraulic model to describe flow characteristics to cause the oxygen distribution in the reactor. The biofilm model represented the oxygen uptake rate by individual bioparticle and the hydrodynamics of fluids presented an axial dispersion flow with back mixing in the liquid phase and a plug flow in the gas phase. The difference of settling velocity along the column height due to the distributions of size and number of bioparticle was considered. The proposed model was able to predict the biomass concentration and the dissolved oxygen concentration along the column height. The removal efficiency of COD was calculated based on the oxygen consumption amounts that were obtained from the dissolved oxygen concentration. The predicted oxygen concentration by the proposed model agreed reasonably well with experimental measurement in a TFBBR. The effects of various operating parameters on the oxygen concentration were simulated based on the proposed model. The media size and media density affected the performance of a TFBBR. The dissolved oxygen concentration was significantly affected by the superficial liquid velocity but the removal efficiency of COD was significantly affected by the superficial gas velocity. An erratum to this article can be found online at .  相似文献   

3.
An approximated analytical solution of mathematical model for the three phase fluidized bed bioreactor (TFBBR) was proposed using the linearization technique to describe oxygen utilization rate in wastewater treatment. The validation of the model was done in comparison with the experimental results. Satisfactory agreement was obtained in the comparison of approximated analytical solution and numerical solution in the oxygen concentration profile of a TFBBR. The approximated solutions for three modes of the liquid phase flow were compared. The proposed model was able to predict the biomass concentration, dissolved oxygen concentration the height of efficient column, and the removal efficiency.  相似文献   

4.
Diesel fuel spills have a major impact on the quality of groundwater. In this work, the performance of an Anaerobic Fluidized Bed Reactor (AFBR) treating synthetic wastewater is experimentally evaluated. The wastewater comprises tap water containing 100, 200 and 300 mg/L of diesel fuel and nutrients. Granular, inert, activated carbon particles are employed to provide support for biomass inside the reactor where diesel fuel is the sole source of carbon for anaerobic microorganisms. For different rates of organic loading, the AFBR performance is evaluated in terms of the removal of diesel fuel as well as chemical oxygen demand (COD) from wastewater. For the aforementioned diesel fuel concentrations and a wastewater flow rate of 1,200 L/day, the COD removal ranges between 61.9 and 84.1%. The concentration of diesel fuel in the effluent is less than 50 mg/L, and meets the Level II groundwater standards of the MUST guidelines of Alberta.  相似文献   

5.
Changes in the bacterial quality of drinking water were examined in the supply system of tropical Dar es Salaam, Tanzania. The water treatment fulfilled WHO standard guidelines. However, the water quality allowed for significant regrowth of bacteria, demonstrating that the WHO guidelines are insufficient to check whether or not the drinking water has an acceptable regrowth potential. An experimental pipe system was examined on site. A growth model was established, based on a zero order bacterial detachment kinetics for the biofilms colonizing the inner surface of the pipes, with a release rate factor R, and a first order growth kinetics in the water flowing in the pipes with a growth rate factor . The rate factors were estimated to be R=1.9×108 m-2 h-1 and =2.5 h-1. It was concluded that growth in the biofilm played a dominant role in the bio-stabilization processes, while the initial microbial quality of the water works water and the growth in the water phase were of minor importance. The bio-stabilization process is understood herein as the reduction in the concentration of nutrients and assimilable organic carbon in the water, and thus as the reduction of the growth potential of the water. Bacterial growth and recontamination were examined during storage at the user site. The results showed that heterotrophic bacteria grew, while faecal coliforms decayed during storage. It was concluded that the users handled the water hygienically.The authors are with the Technical University of Denmark, IMT, CDC-Build, 208 DK-2800 Lyngby, Denmark  相似文献   

6.
Degradation kinetics of phenol by free and agar-entrapped cells of Candida tropicalis was studied in batch cultures. The initial phenol degradation rate achieved with free cells was higher than that obtained with immobilized cells, when phenol concentrations up to 1000 mg l–1 were used. However, at higher phenol concentrations, the behaviour was quite different. The initial degradation rate of the immobilized yeast cells was about 10 times higher than that of the free cells, at a phenol concentration of 3500 mg l–1. The semicontinuous and continuous degradation of phenol by immobilized yeast cells was also investigated in a multi-stage fluidized bed reactor. The highest phenol removal efficiencies and degradation rates as well as the lowest values of residual phenol and chemical oxygen demand were obtained in the semicontinuous culture when phenol concentrations up to 1560 mg l–1 were used.  相似文献   

7.
Sulfidogenic fluidized bed treatment of real acid mine drainage water   总被引:1,自引:0,他引:1  
The treatment of real acid mine drainage water (pH 2.7-4.3) containing sulfate (1.5-3.34 g/L) and various metals was studied in an ethanol-fed sulfate-reducing fluidized bed reactor at 35 °C. The robustness of the process was tested by increasing stepwise sulfate, ethanol and metal loading rates and decreasing feed pH and hydraulic retention time. Highest sulfate reduction rate (4.6 g/L day) was obtained with feed sulfate concentration of 2.5 g/L, COD/sulfate ratio of 0.85 and HRT of 12 h. The corresponding sulfate and COD removal efficiencies were about 90% and 80%, respectively. The alkalinity produced in sulfidogenic ethanol oxidation neutralized the acidic mine water. Highest metal precipitation efficiencies were observed at HRT of 24 h, the percent metal removal being over 99.9% for Al (initial concentration 55 mg/L), Co (9.0 mg/L), Cu (49 mg/L), Fe (435 mg/L), Ni (3.8 mg/L), Pb (7.5 mg/L) and Zn (6.6 mg/L), and 94% for Mn (7.21 mg/L).  相似文献   

8.
This study evaluated the treatment of oil sands process-affected water (OSPW) using a fluidized bed biofilm reactor (FBBR) with granular activated carbon (GAC) as support media. The bioreactor was operated for 120 days at different organic and hydraulic loading rates. The combined GAC adsorption and biodegradation process removed 51% of chemical oxygen demand (COD), 56% of acid-extractable fraction (AEF) and 96% of classical naphthenic acids (NAs) under optimized operational conditions. Bioreactor treatment efficiencies were dependent on the organic loading rate (OLR), and to a lower degree, on the hydraulic loading rate (HLR). Further ultra performance liquid chromatography/high resolution mass spectroscopy (UPLC/HRMS) analysis showed that the removal of classical NAs increased as the carbon number increased. Compared with planktonic bacterial community in OSPW, more diverse microbial structures were found in biofilms colonized on the surface of GAC after 120-day treatment, with various carbon degraders namely Polaromonas jejuensis, Algoriphagus sp., Chelatococcus sp. and Methylobacterium fujisawaense in the GAC-biofilm reactor. The results of this study, therefore, showed that the GAC-biofilm seems to be a promising biological treatment method for OSPW remediation.  相似文献   

9.
The present study evaluates the groundwater quality for drinking and agricultural purposes and determines physicochemical characteristics of groundwater in the Sistan and Baluchistan province in Iran. In order to investigate the water quality, sampling was done in 654 open dug wells, the chemical parameters were analyzed, and water quality index was determined. In this regard, Langelier saturation index (LSI), Ryznar Stability index (RSI), Puckorius scaling index (PSI), Larson–Skold index (LS), and Aggressiveness index (AI) were considered to determine water suitability for industrial purposes. Finally, the analytical results were taken to generate the numerical spatial distribution of the parameters using the geographic information system (GIS) environment. According to the results, water sources were less corrosive based on AI and PSI, low and light corrosion according to RSI, and corrosion according to the Larsson–Sckold index. The results of the drinking water quality index showed that 1.2% shared extraction wells were classified as excellent, 52.1% as good, 39% as poor, 6% as very poor, and 1.7% as unsuitable for drinking purpose classes. In addition, irrigating water quality index illustrated that 19.9% and 80.1% wells were placed in the “excellent” and “Good” classes, respectively. Also, the quality of water in this study was categorized as brackish.  相似文献   

10.
11.
Fluidized bed reactor (FBR) technology has emerged in recent years as an attractive approach for the biotreatment of chemical industry wastestreams. A laboratory-scale FBR study was conducted to investigate the feasibility of utilizing FBR technology for the biotreatment of maleic anhydride wastewater generated during manufacturing operations. The maleic anhydride wastestream contains a mixture of maleic acid, fumaric acid, phthalic acid and di-n-butylphthalate (DBP). The FBR removed >98% of chemical oxygen demand (COD) and total organic carbon (TOC) from the wastewater at a chemical loading rate of 4.86 kg of COD m–3 bed day–1. Maleic acid, fumaric acid or phthalic acid were not detected in the FBR effluent indicating removal of these diacids. Residues of DBP adsorbed to granular activated carbon (GAC) stabilized at low levels indicating that the >99% removal efficiency for DBP in the FBR resulted from microbial degradation. Solids measurements showed microbial biomass levels on the GAC ranging from 10500 to 32400 mg L–1 and effluent solids production ranged from 0.027 to 0.041 kg solids kg–1 COD treated. This laboratory-scale study demonstrated that FBR technology was highly effective for the biotreatment of the maleic anhydride wastestream and may offer several advantages over traditional activated sludge systems.  相似文献   

12.
Several families of Talca city, Chile complained to health authorities for what they attributed to consumption of copper (Cu)-contaminated drinking water. We assessed the situation 6–12 mo after the initiation of complaints by characterizing the symptoms reported, the chemistry of drinking water, and the Cu concentration in stagnant drinking water. After completing a census, 1778 households accepted participation and were categorized as follows: category 1, Cu plumbing for tap water and dwellers reporting health complaints (HC); category 2, Cu plumbing for tap water and dwellers reporting no HC; category 3, plastic plumbing for tap water and dwellers reporting no HC. Questionnaires recorded characteristics of households and symptoms presented by each member of the family in the last 3 mo. The Cu concentration in drinking water was measured in a subsample of 80 homes with Cu pipes. In category 1, participants presented significantly more abdominal pain, diarrhea, and/or vomiting (gastrointestinal [GI] symptoms) in comparison to category 3 and to categories 2 plus 3. The stagnant Cu concentrations measured in drinking water in all houses studied were below the US Environmental Protection Agency guideline value (<1.3 mg Cu/L). In summary, data obtained by interviews suggested that individuals in some areas of Talca city were suffering more GI symptoms potentially related to Cu excess, but measurement of Cu concentration in stagnant tap waters ruled out the association between Cu exposure and GI symptom reports at the time of this study. The dose-response curves for GI symptoms and Cu exposure now available were crucial in the analyses of results.  相似文献   

13.
Shin C  Lee E  McCarty PL  Bae J 《Bioresource technology》2011,102(21):9860-9865
The effect of influent DO/COD (dissolved oxygen/chemical oxygen demand) ratio on the performance of an anaerobic fluidized bed reactor (AFBR) containing GAC was studied. A high influent DO concentration was found to have adverse impacts on organic removal efficiency, methane production, and effluent suspended solids (SS) concentration. These problems resulted with a DO/COD ratio of 0.12, but not at a lower ratio of 0.05. At first organic removal appeared satisfactory at the higher DO/COD ratio at a hydraulic retention time of 0.30 h, but soon a rapid growth of oxygen-consuming zoogloeal-like organisms resulted, eventually causing high effluent SS concentrations. The influent DO also had an inhibitory effect, resulting in a long recovery time for adequate methanogenic activity to return after influent DO removal began. With the growing interest in anaerobic treatment of low COD wastewaters, the increased possibility of similar adverse DO effects occurring needs consideration.  相似文献   

14.
Aim: To determine if exposure of Pseudomonas aeruginosa biofilms to chloraminated drinking water can lead to individual bacteria with resistance to antibiotics. Methods and Results: Biofilms of P. aeruginosa PA14 were grown in drinking water in a Kadouri drip‐fed reactor; the biofilms were treated with either 0·5 mg l‐1 or 1·0 mg l‐1 of chloramine for 15 or 21 days; control biofilms were grown in water without chloramine. Fewer isolates with antibiotic resistance were obtained from the chloramine‐treated biofilms as compared to the control. Minimum inhibitory concentrations (MIC) for selected antibiotic‐resistant isolates were determined using ciprofloxacin, tobramycin, gentamicin, rifampicin and chloramphenicol. All of the isolates tested had increased resistance over the wildtype to ciprofloxacin, rifampicin and chloramphenicol, but were not resistant to tobramycin or gentamicin. Conclusions: Under these test conditions, there was no detectable increase in antibiotic resistance in P. aeruginosa exposed as biofilms to disinfectant residues in chloraminated drinking water. Significance and Impact of the study: Chloramine in drinking water, while unable to kill biofilm bacteria, does not increase the potential of P. aeruginosa to become resistant to antibiotics.  相似文献   

15.
A bioluminescent assay of total bacterial contamination (TBC) of drinking water (DW) with a detection limit of approximately 1 CFU/mL and duration of less than 7 h has been developed. The protocol of the TBC assay comprises: incubation of water sample in nutrition broth supplemented with salts mixture, up to 6 h; filtration of bacterial suspension obtained through membrane filter (pore size 0.45 microm); release of bacterial ATP by dimethyl sulphoxide; determination of bacterial ATP concentration using highly sensitive ATP reagent based on recombinant Luciola mingrelica luciferase. To simplify the assay, special luminometer microcuvette Filtravette (New Horizons Diagnostics Corp., USA) are used. A good correlation (R=0.98) between ATP concentration measured after 6 h incubation and initial bacterial titre in DW was observed. Semi-quantitative TBC assay of DW is also available. The TBC value in DW is assessed by the fixation of incubation time required to detect a measurable bioluminescent signal: 3, 4 and 6 h corresponds to 100-1000, 10-100 and 1-10 CFU/mL, respectively.  相似文献   

16.
Aims:  To determine the impact of natural sunlight in disinfecting water contaminated with cysts of Giardia duodenalis and Entamoeba histolytica/dispar using plastic containers.
Methods and Results:  Known quantities of Giardia duodenalis and Entamoeba histolytica/dispar cysts in sterile water were exposed to the sun. Containers were made of polyethylene terephthalate, eight painted black on one side, one not painted and another cut open at the top and the last was a high density polypropylene container. Viability testing was performed using vital and fluorescent dyes. The same assays were conducted under cloudy conditions. Thermal control tests were also performed using heat without ultra violet light from the sun. Results show that 99·9% of parasites was inactivated when water temperatures reached 56°C after sunlight exposure.
Conclusion:  Both solar radiation and heat produced by the sun have a synergistic effect in killing cysts of Giardia duodenalis and Entamoeba histolytica/dispar when temperatures rise above 50°C, with complete death at 56°C, using painted 2-l PET containers.
Significance and Impact of the Study:  Solar disinfection system using PET containers painted black on one side can be used to disinfect water against Giardia duodenalis and Entamoeba histolytica/dispar using natural sunlight.  相似文献   

17.
This study reports the feasibility of recovering metal precipitates from a synthetic acidic wastewater containing ethanol, Fe, Zn, and Cd at an organic loading rate of 2.5 g COD/L-day and a COD to sulfate ratio of 0.8 in a sulfate reducing down-flow fluidized bed reactor. The metals were added at increasing loading rates: Fe from 104 to 320 mg/L-day, Zn from 20 to 220 mg/L-day, and Cd from 5 to 20 mg/L-day. The maximum COD and sulfate removals attained were 54% and 41%, respectively. The biofilm reactor was operated at pH as low as 5.0 with stable performance, and no adverse effect over COD consumption or sulfide production was observed. The metals precipitation efficiencies obtained for Fe, Zn, and Cd exceeded 99.7%, 99.3%, and 99.4%, respectively. The total recovered precipitate was estimated to be 90% of the theoretical mass expected as metal sulfides. The precipitate was mainly recovered from the bottom of the reactor and the equalizer. The analysis of the precipitates showed the presence of pyrite (FeS2), sphalerite (ZnS) and greenockite (CdS); no metal hydroxides or carbonates in crystalline phases were identified. This study is the first in reporting the feasibility to recover metal sulfides separated from the biomass in a sulfate reducing process in one stage.  相似文献   

18.
19.
20.
典型亚热带热分层水库秋季细菌群落垂直分布   总被引:6,自引:0,他引:6  
周菁  余正  刘开国  田野  余小青  刘乐冕  张文静  杨军 《生态学报》2014,34(21):6205-6213
水库在我国东南沿海地区是重要的饮用水水源地,对地区经济发展和社会稳定起到重要作用。选择亚热带地区典型的热分层水库——福建莆田东圳水库,于2011年秋季稳定分层期,以水体温度的垂直变化特征为依据进行分层采样。应用PCRDGGE和克隆测序的方法研究浮游细菌群落的垂直分布特征,利用多元统计分析揭示细菌群落与热分层水体理化指标之间的关系。结果显示:溶解氧、电导率、叶绿素a、总氮、氨氮及硝氮在上下层水体中的分布有显著差异,下层缺氧区细菌的ShannonWiener指数和DGGE条带数明显高于上层好氧区,表明东圳水库热分层水体中存在明显的物理、化学及生物分层现象。测序结果表明β-变形菌可能是东圳水库中占优势的细菌类群,统计结果提示溶解氧是显著影响细菌群落组成的环境因子。热分层水体的物理化学分层与水体细菌群落结构密切相关,提示水库生态学研究应对水体热分层给予重视。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号