首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study describes the feasibility of anaerobic treatment of synthetic coal wastewater using four identical 13.5L (effective volume) bench scale hybrid up flow anaerobic sludge blanket (HUASB) reactors (R1, R2, R3 and R4) under mesophilic (27+/-5 degrees C) conditions. Synthetic coal wastewater with an average chemical oxygen demand (COD) of 2240 mg/L and phenolics concentration of 752 mg/L was used as substrate. Effluent recirculation was employed at four different effluent to feed recirculation ratios (R/F) of 0.5, 1.0, 1.5 and 2.0 for 100 days to study the effect of recirculation on the performance of the reactors. Phenolics and COD removal was found to improve with increase in effluent recirculation. An effluent to feed recycle ratio of 1.0 resulted in maximum removal of phenolics and COD. Phenolics and COD removal improved from 88% and 92% to 95% each, respectively. The concentration of volatile fatty acids in the effluent was lower than the influent when effluent to feed recirculation was employed. Effect of shock loading on the reactors revealed that phenolics shock load up to 2.5 times increase in the normal input phenolics concentration in the form of continuous shock load for 4days did not affect the reactors performance irreversibly.  相似文献   

2.
The aim of this work was to study the influence of influent chemical oxygen demand (COD), upflow velocity of wastewater, and cationic polymer additives in inoculum, on biomass granulation and COD removal efficiency in upflow anaerobic sludge blanket (UASB) reactor for treating low strength wastewater. Statistical models were formulated based on these three variables to optimize the biomass granulation and COD removal efficiency in UASB reactors using a two-level, full factorial design. For the thick inoculum used in this study, having suspended solids (SS) >80 g/l and volatile suspended solids (VSS) to SS ratio <0.3, cationic polymer additives in the inoculum showed adverse effect on biomass granulation and COD removal efficiency. It is concluded that for such thick inoculum, granulation can be obtained while treating low strength wastewaters in UASB reactor by selecting proper combination of influent COD and liquid upflow velocity so as to represent the organic loading rate (OLR) greater than 1.0 kg COD/m(3) d. Validation of model predictions for treatment of synthetic wastewater and actual sewage reveals the efficacy of these models for enhancing granulation and COD removal efficiency.  相似文献   

3.
With the rapid development of scaled anaerobic digestion of pig manure, the generation of liquid anaerobic digestate exceeds the farmland loading capacity, causing serious environmental pollution. Three laboratory‐scale horizontal subsurface flow constructed wetlands (CWs; planted + aeration, planted, and unplanted) were set up to investigate the feasibility of liquid digestate treatment in wetlands. Treatment capacity in different wetlands was evaluated under different influent concentrations (chemical oxygen demand [COD], 5 days biochemical oxygen demand [BOD5], and nitrogen forms). The effect of aeration and effluent recirculation on organic matter and total nitrogen removal was investigated. Results showed that integrating intermittent aeration in CWs significantly improved the oxygen condition (p < 0.01) in the wetland bed and promoted BOD5 removal to 90% in aerated CWs as compared with <15% in the unaerated CWs. Meanwhile, COD removal between these three wetlands did not show any difference and varied from 52 to 72% under influent concentration of 200–820 mg/L because of the high content of hard‐degradable organic matter in the liquid digestate. Intermittent aeration resulted in high ammonium removal (>98%) although the influent loading varied from 65 to 350 mg/L. However, intermittent aeration caused nitrate accumulation of 300 mg/L and limited total nitrogen (TN) removal of 33%. To intensify the TN removal, we verified effluent recirculation to increase the removal efficiency of TN to 78%. These results not only show the potential application of CWs for treatment of high‐strength liquid anaerobic digested slurry, but also indicate the significance of intermittent aeration on the enhanced removal of organic matter and ammonium.  相似文献   

4.
Cephalexin is a constituent of the cephalosporin group used for the treatment of bronchitis and other heart diseases due to its enhanced oral activity. The effluent from these industries contains a disintegrated form of the drug contributing high chemical oxygen demand (COD), volatile solids and organic solvent. A laboratory-scale study was conducted to evaluate the efficiency of a fluidized bed reactor operated under anaerobic condition with bioaugmentation to treat the cephalexin containing pharmaceutical factory effluent. The main objective of the study was to show that bioaugmentation could be used to promote biological treatment to applications where conventional operation might be difficult or unfavourable. The effluent, with COD of 12,000-15,000 mg/l, was diluted and studied in single and multiple inoculation experiments with hydraulic retention times of 3-12 h. The removal efficiency after inoculation from an anaerobic sequencing batch reactor was related to influent concentration, mass of inoculum and hydraulic retention time characterized by calculating the initial food to microorganism ratio. Continuous COD removal efficiency attained a maximum value of 88.5% using bioaugmentation through periodic addition of acclimated cells every 2 days with 30-73.2 g of cells from an off-line enricher-reactor.  相似文献   

5.
Low strength wastewaters can be those with chemical oxygen demand (COD) below 2,000 mg/l. The anaerobic treatment of such wastewaters has not been fully explored so far. The suboptimal reaction rates with low substrate concentrations, and the presence of dissolved oxygen in the influent are regarded as possible constraints. In this study, the treatment of low strength soluble wastewaters containing ethanol or whey was studied in lab-scale upflow anaerobic sludged bed (UASB) reactors at 30°C. The high treatment performance obtained demonstrates that UASB reactors are viable for treating both types of wastewaters at low COD concentrations. The treatment of the ethanol containing wastewater resulted in COD removal efficiencies exceeding 95% at organic loading rates (OLR) between 0.3 to 6.8 g COD/l-d with influent concentrations in the range of 422 to 943 mg COD/l. In the case of the more complex whey containing wastewater, COD removal efficiencies exceeded 86% at OLRs up to 3.9 g COD/l·, as long as the COD influent was above 630 mg/l. Lowering the COD influent resulted in decreased efficiency with sharper decrease at values below 200 mg/l. Acidification instead of methanogenesis was found to be the rate limiting step in the COD removal at low concentrations, which was not the case when treating ethanol. The effect of dissolved oxygen in the influent as a potential danger in anaerobic treatment was investigated in reactors fed with and without dissolved oxygen. Compared with the control reactor, the reactor receiving oxygen showed no detrimental effects in the treatment performance. Thus, the presence of dissolved oxygen in dilute wastewaters is expected to be of minor importance in practice.  相似文献   

6.
A simple, efficient and cost-effective method for municipal wastewater treatment is examined in this paper. The municipal wastewater is treated using an upflow anaerobic sludge bed (UASB) reactor followed by flash aeration (FA) as the post-treatment, without implementing aerobic biological processes. The UASB reactor was operated without recycle, at hydraulic retention time (HRT) of 8 h and achieved consistent removal of BOD, COD and TSS of 60-70% for more than 12 months. The effect of FA on UASB effluent post-treatment was studied at different HRT (15, 30 and 60 min) and dissolved oxygen (DO) concentrations (low DO = 1-2 mg/L and high DO = 5-6 mg/L). The optimum conditions for BOD, COD and sulfide removal were 30-60 min HRT and high DO concentration inside the FA tank. The final effluent after clarification was characterized by BOD and COD values of 28-35 and 50-58 mg/L, respectively. Sulfides were removed by more than 80%, but the fecal coliform only by ~2 log. The UASB followed by FA is a simple and efficient process for municipal wastewater treatment, except for fecal coliform, enabling water and nutrients recycling to agriculture.  相似文献   

7.
分段组合式厌氧反应器预警性能   总被引:1,自引:0,他引:1  
采用模拟有机废水,研究了分段组合式厌氧反应器 (Compartmentalized anaerobic reactor,CAR) 的预警性能。试验结果表明:高效厌氧反应器的运行稳定性低于常效厌氧反应器。在高效工况下,进水的化学需氧量 (Chemical oxygen demand,COD) 浓度的小幅提升 (平均相对标准偏差为8.08%) 可引起出水COD浓度 (平均相对标准偏差为32.95%) 和出水挥发性脂肪酸 (Volatile fatty acids,VFA) 浓度 (平均相对标准偏差为40.46%) 的大幅增加。容积负荷饱和度和VFA饱和度与反应器工况密切相关,可用于厌氧反应过程的预警。常负荷工况下 (容积负荷饱和度和VFA饱和度低于0.89与0.40),反应运行性能稳定;满负荷工况下 (容积负荷饱和度和VFA饱和度趋近1),反应运行性能波动增大;超负荷工况下 (容积负荷饱和度和VFA饱和度超过1),反应运行性能恶化。  相似文献   

8.
A lab-scale investigation was conducted to examine the effectiveness of a multi-fed upflow anaerobic filter process for the methane production from a rice winery effluent at ambient temperatures. The experiment was carried in two identical 3.0-l upflow filters, a single-fed reactor and a multi-fed reactor. The results showed that the multi-fed reactor, operated at the ambient temperatures of 19–27 °C and influent chemical oxygen demand (COD) of 8.34–25.76 g/l, could remove over 82% of COD even at an organic loading rate (OLR) of 37.68 g-COD/l d and a short hydraulic retention time (HRT) of 8 h. This reactor produced biogas with a methane yield of 0.30–0.35 l-CH4/g-CODremoved. The multi-fed upflow anaerobic filter was proved to be more efficient than the single-fed reactor in terms of COD removal efficiency and stability against hydraulic loading shocks. A linear-regression model with influent COD concentration and HRT terms adequately described the multi-fed upflow anaerobic filter system for the treatment of rice winery wastewater at ambient temperatures.  相似文献   

9.
实验室模拟高负荷SPAC厌氧反应器运行   总被引:6,自引:1,他引:5  
采用模拟废水, 对新型高负荷螺旋式自循环(Spiral automatic circulation, SPAC)厌氧反应器的运行性能进行了实验室模拟研究。结果表明: 在30oC, 水力停留时间(HRT)为12 h, 进水COD浓度从8000 mg/L升至20 000 mg/L的条件下, 反应器的COD去除率为91.1%~95.7%, 平均去除率为93.6%。在进水浓度为20 000 mg/L, HRT由5.95 h缩短至1.57 h的工况下, COD去除率从96.0%降低至78.7%, 反应器达到最高容积负荷率306 g COD/(L·d), 最大容积COD去除率240 g/(L·d), 最高容积产气率131 L/(L·d)。该反应器对基质浓度的连续提升具有良好的适应能力。进水COD浓度由8000 mg/L提升至20 000 mg/L时, 出水COD浓度一直处在较低水平(平均为852?mg/L), 容积COD去除率和容积产气率分别提高162%和119%。该反应器对HRT的连续缩短也有良好的适应能力。HRT由5.95 h缩短至1.57 h时,反应器容积COD去除率和容积产气率分别升高191%和195%。  相似文献   

10.
In order to investigate the influence of hydraulic retention time (HRT) on organic pollutant removal in a submerged membrane bioreactor (SMBR), a laboratory-scale experiment was conducted using domestic sewage as influent. The dissolved oxygen (DO) concentration was controlled at 2.0– during the experimental period. The experiments demonstrated that when HRT was 3, 2 and 1 h, the reduction of chemical oxygen demand (COD) was 89.3–97.2, 88.5–97.3 and 80–91.1%, and the effluent COD was 38.9–11.2, 41.6–10.8 and 63.4–, respectively. It is suggested that an HRT of 1 h could meet the normal standard of discharged domestic sewage, and an HRT of 2 h could meet that of water reclamation. In addition, we use mathematical software MATLAB to analyse the relation of mixed liquor suspended solids (MLSS) and COD removal. The results showed that the optimum MLSS concentration should be maintained at around in the SMBR. The results also showed that the COD removal was related to HRT (τ), influent concentration (S0) and sludge loading rate for COD removal (NS). Moreover, the high COD removal could be achieved through adjusting τ, S0 and NS.  相似文献   

11.
The goal of the study was to determine the effectiveness of nitrification and denitrification and the kinetics of ammonia removal from a mixture of wastewater and anaerobic sludge digester supernatant in an SBR at limited oxygen concentration. In addition, the COD removal efficiency and sludge production were assessed.In the SBR cycle alternating aerobic and anaerobic phases occurred; in the aeration phase the dissolved oxygen (DO) concentration was below 0.7 mg O2/L. The low DO concentration did not inhibit ammonia oxidation-nitrification and the efficiency was ca. 96-98%. However, a relatively high COD concentration in the effluent was detected. The values of Km and Vmax, calculated from the Michaelis-Menten equation, were 43 mg N-NH4/L and 15.64 mg N-NH4/L h, respectively. Activated sludge production was almost stable (0.62-0.66 g MLVSS/g COD). A high net biomass production resulted from a low specific biomass decay rate of 0.0015 d−1.  相似文献   

12.
Choi C  Lee J  Lee K  Kim M 《Bioresource technology》2008,99(13):5397-5401
An intermittently aerated membrane bioreactor (IAMBR) system has been developed to improve the efficiency of nutrient removal, and for the stable treatment of organic matter which is contained as suspended solid (SS) in the influent. The important operating factors of an intermittently aerated bioreactor (IABR) are sludge retention times (SRTs) and carbon/nitrogen (C/N) ratios. Because research on IAMBR is young, this paper explores the effect of SRTs and C/N ratios on these systems. For SRTs of 20, 25, 30, and 40 days, there was little difference in the removal of COD, T–N, and T–P. In comparing C/N ratios of 4.5, 7, and 10, the COD concentration in permeate with a C/N ratio of 10 was most stable, although the concentration of organic matter in the influent was high. The removal efficiencies of T–N and T–P in permeate with a C/N ratio of 10 were the highest at 92.9% and 88.9%, respectively. This implies that a C/N ratio above 10 should be maintained for a nutrient removal efficiency of approximately 90%.  相似文献   

13.
This study was focused on several physico-chemical and biological treatment methods that may affect the reduction of the organic load in olive mill wastewater (OMW). In this study, removal of 95% of the phenolic compounds present in OMW was achieved using sand filtration and subsequent treatment with powdered activated carbon in a batch system. This pretreatment for OMW was found to enhance the anaerobic activity of the sludge in the batch system significantly. The efficiency of organic load removal achieved by the anaerobic treatment of untreated OMW in batch reactors with tap water dilution factors below 1:10, reached approximately 65% chemical oxygen demand (COD) removal. However, in the up-flow sludge anaerobic blanket (UASB) reactor, COD removal efficiency of 80–85% was reached at a hydraulic retention time (HRT) of 5 days with an influent COD concentration of 40 g l−1 and organic loading rate (OLR)=8 g−1 COD l−1 per day.  相似文献   

14.
Anaerobic biological wastewater treatment has numerous advantages over conventional aerobic processes; anaerobic biotechnologies, however, still have a reputation for low-quality effluents and operational instabilities. In this study, anaerobic bioreactors were augmented with an oxygen-transferring membrane to improve treatment performance. Two anaerobic bioreactors were fed a synthetic high-strength wastewater (chemical oxygen demand, or COD, of 11,000 mg l(-1)) and concurrently operated until biomass concentrations and effluent quality stabilized. Membrane aeration was then initiated in one of these bioreactors, leading to substantially improved COD removal efficiency (> 95%) compared to the unaerated control bioreactor (approximately 65%). The membrane-augmented anaerobic bioreactor required substantially less base addition to maintain circumneutral pH and exhibited 75% lower volatile fatty acid concentrations compared to the unaerated control bioreactor. The membrane-aerated bioreactor, however, failed to improve nitrogenous removal efficiency and produced 80% less biogas than the control bioreactor. A third membrane-augmented anaerobic bioreactor was operated to investigate the impact of start-up procedure on nitrogenous pollutant removal. In this bioreactor, excellent COD (>90%) and nitrogenous (>95%) pollutant removal efficiencies were observed at an intermediate COD concentration (5,500 mg l(-1)). Once the organic content of the influent wastewater was increased to full strength (COD = 11,000 mg l(-1)), however, nitrogenous pollutant removal stopped. This research demonstrates that partial aeration of anaerobic bioreactors using oxygen-transferring membranes is a novel approach to improve treatment performance. Additional research, however, is needed to optimize membrane surface area versus the organic loading rate to achieve the desired effluent quality.  相似文献   

15.
High concentration of heavy metals is toxic for most microorganisms and cause strict damage in wastewater treatment operations and often a physico-chemical pretreatment prior to biological treatment is considered necessary. However, in this study it has been shown that biological systems can adapt to Ni (II) and Cr (VI) when their concentration is below 10 and 20 mg/L, respectively. The aim of this study was to evaluate the effect of Ni (II) and Cr (VI) on the lab-scale rotating biological contactor process. It was found that, addition of Ni (II) up to 10 mg/L did not reduce the chemical oxygen demand removal efficiency and on the contrary concentrations below 10 mg/L improved the performance. The influent Ni (II) concentration of 1 mg/L was the concentration where the treatment efficiency produced a maximum COD removal of 86.5%. Moreover, Ni (II) concentration above 10 mg/L was relatively toxic to the system and produced lower treatment efficiencies than the baseline study without Ni (II). Turbidity and suspended solids removals were not stimulated to a great extent with nickel. Addition of Ni (II) did not seem to affect the pH of the system during treatment. The dissolved oxygen concentration did not drop below 4 mg/L at all concentrations of Ni (II) indicating aerobic conditions prevailed in the system. Experiments conducted with Cr (VI) revealed that addition of Cr (VI) up to 20 mg/L did not reduce the COD removal efficiency and on the contrary concentrations below 20 mg/L improved the performance. The influent Cr (VI) concentration of 1 mg/L was the concentration where the treatment efficiency produced a maximum COD removal of 88%. Turbidity and SS removals were more efficient at 5 mg/L Cr (VI) concentration, rather than 1 mg/L, which lead to the conclusion that 5 mg/L Cr (VI) concentration is the optimum concentration, in terms of COD, turbidity and SS removals. Similar with Ni (II) experiments, addition of Cr (VI) did not significantly affect the pH value of the effluent. The DO concentration remained above 5 mg/L.  相似文献   

16.
The supernatant from mesophilic anaerobic digestion of piggery wastewater is characterised by a high amount of COD (4.1 g COD L(-1)), ammonium (2.3g NH(4)(+)-NL(-1)) and suspended solids (2.5 g SS L(-1)). This effluent can be efficiently treated by means of a Sequencing Batch Reactor (SBR) strategy for biological COD, SS and nitrogen removal including a Coagulation/Flocculation step. Total COD and SS reduction yields higher than 66% and 74%, respectively, and a total nitrogen removal (via nitrite) of more than 98% were reached when working with HRT 2.7 days, SRT 12 days, temperature 32 degrees C, three aerobic/anoxic periods, without external control of pH and under limited aeration flow. The inhibition of nitrite oxidizing biomass was achieved by the working free ammonia concentration and the restricted air supply (dissolved oxygen concentration below 1 mg O(2)L(-1)). Since a part of the total COD was colloidal and/or refractory, a Coagulation/Flocculation step was implemented inside the SBR operating strategy to meet a suitable effluent quality to be discharged. Several Jar-Tests demonstrated that the optimal concentration of FeCl(3) was 800 mg L(-1). A respirometric assay showed that this coagulant dosage did not affect the biological activity of nitrifying/denitrifying biomass.  相似文献   

17.
The primary objective of this study was to evaluate the effects of the organic loading rate on the performance of an up-flow anaerobic sludge blanket (UASB) reactor treating olive mill effluent (OME), based on the following indicators: (i) chemical oxygen demand (COD) removal efficiency; and (ii) effluent variability (phenol, suspended solids, volatile fatty acids, and pH stability). The UASB reactor was operated under different operational conditions (OLRs between 0.45 and 32 kg COD/m3·day) for 477 days. The results demonstrated that the UASB reactor could tolerate high influent COD concentrations. Removal efficiencies for the studied pollution parameters were found to be as follows: COD, 47∼92%; total phenol, 34∼75%; color, 6∼46%; suspended solids, 34∼76%. The levels of VFAs in the influent varied between 310 and 1,750 mg/L. Our measurements of the VFA levels indicated that some of the effluent COD could be attributed to VFAs (principally acetate, butyrate, iso-butyrate, and propionate) in the effluent, which occurred at levels between 345 and 2,420 mg/L. As the OLRs were increased, more VFAs were measured in the effluent. A COD removal efficiency of 90% could be achieved as long as OLR was kept at a level of less than 10 kg COD/m3·day. However, a secondary treatment unit for polishing purposes is necessary to comply with discharge standards.  相似文献   

18.
The primary objective of this study was to evaluate the performance of a 20 l lab scale anaerobic hybrid reactor (AHR) combining sludge blanket in the lower part and filter in the upper part under varying organic loading rates (OLRs) in order to study biodegradation of olive mill effluent (OME). For this purpose, some parameters, such as total phenols, effluent chemical oxygen demand (COD), suspended solids (SS), volatile fatty acids (VFAs), and pH in the influent and effluent, and removal efficiencies for those parameters (except pH) were continuously monitored throughout the experimental period of 477 days. Eleven different organic loadings between 0.45 and 32 kg COD m−3 day−1 were imposed by either varying influent COD or hydraulic retention time (HRT). The results demonstrated that the AHR reactor could tolerate high influent COD concentrations. Removal efficiencies for the studied pollution parameters were found to be as follows: COD, 50–94%; total phenol, 39–80%; color, 0–54%; and suspended solids, 19–87%. The levels of VFAs in the effluent, which was principally acetate, butyrate, iso-butyrate, and propionate, varied between 10 and 2005 mg l−1 depending upon OLRs. A COD removal efficiency of 90% could be achieved as long as OLR is kept at a level of less than 10 kg COD m−3 day−1. However, a secondary treatment unit for polishing purposes is necessary to comply with receiving media discharge standards.  相似文献   

19.
Raw leachate was treated using a two-stage upflow anaerobic filter process. Leachate from a solid waste landfill site, which received both municipal and industrial wastes, contained high organic matter (17-21 g/L COD, 13-14 g/L BOD, and 3.5-4.6 g/L volatile acids), and low metal (Zn and Fe) concentrations. Depending on sampling time, leachate composition and characteristics varied considerably. At an organic loading up to 4 g COD/day(2) media area, the BOD and COD removal percentages were 98 and 91%, respectively. The biofilters were also effective for metal removal. However, the filter effluent contained a high concentration of ammonia. System overloading was characterized by the accumulation of large quantities of volatile acids and by a now ratio of alkalinity/volatile acids, resulting in low COD removal and reduced gas production. Once the first filter was upset, the second stage could only partially respond to the volatile acids accumulated in the effluent of first filter.  相似文献   

20.
Lim SJ  Fox P 《Bioresource technology》2011,102(22):10371-10376
An anaerobic/aerobic filter (AF/BAF) system was developed treating dairy wastewater. The influent was blended with recirculated effluent to allow for pre-denitrification in the AF followed by nitrification in the BAF. The recirculation ratio ranged 100-300%. The average chemical oxygen demand (COD) removal efficiency was 79.8-86.8% in the AF and the average total nitrogen removal efficiency was 50.5-80.8% in the AF/BAF system. Steady-state mass balances on the AF were used to analyze removal kinetics in the AF. The kinetic model values for effluent COD in the AF were overestimated as compared with experimental data. The integrated suspended and attached biomass growth rates in the AF were estimated. The specific growth rate of the integrated biomass at each recirculation ratios was 0.6213, 0.6647, and 1.20831/day, respectively. The increase in specific growth rate corresponded to increases in biomass sloughing as the recirculation ratio increased.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号